Search NASA⌕ Search

SEARCH · Search NASA

Results for “response surface methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Current status of silicon solar cell technology

Recent advances in solar cell technology have led to the development of laboratory cells with efficiencies above 15% and production cells with efficiencies in the area of 13%. The increased output is largely the result of increases in the short-circuit current. The most significant gain in the amount of light entering the cell has been obtained through surface texturing by chemical etching techniques. Sheet resistances resulting from phosphorus diffusion in the 800 C temperature range yield junction depths on the order of 0.1 micrometer, leading to significant increases in the blue region of the cell spectral response. The inclusion of a back surface field in 10 ohm-cm cells has produced an increase in open-circuit voltage of about 50 mV and an increase in the minority carrier lifetime. It appears that a low emitter efficiency of the diffused region is the cause of poor voltages. Future research will be primarily directed toward correcting this deficiency and toward the development of low cost production methods.

Brandhorst, H. W., Jr.↗

Genesis lunar outpost criteria and design

This design study--the third in the space architecture series--focused on the requirements of an early stage lunar outpost. The driving assumptions of the scenario was that the base would serve as a research facility and technology testbed for future Mars missions, a habitat supporting 12 persons for durations of up to 20 months, and would sustain the following five experimental facilities: Lunar surface mining and production analysis facility, construction technology and materials testbed, closed environmental life support system (CELSS) test facility, lunar farside observatory, and human factors and environment-behavior research facility. Based upon the criteria set forth in a previous programming document, three preliminary lunar base designs were developed. Each of the three schemes studied a different construction method and configuration. The designs were then evaluated in terms of environmental response, human habitability, transportability, constructability, construction dependability and resilience, and their suitability in carrying out the desired scientific research. The positive points of each scheme were then further developed by the entire project team, resulting in one integrated lunar outpost design.

Hansmann, Timothy↗

Method of evaluating pH using a metallic nanoparticle incorporated nanocomposite-based optical pH sensor

A method for evaluating the pH of an aqueous solution by utilizing the optical properties of a pH sensing material comprised of plurality of optically active nanoparticles dispersed in matrix material. The optically active nanoparticles have an electronic conductivity greater than about 10−1 S/cm and generally have an average nanoparticle diameter of less that about 500 nanometers, and the matrix material is a material which experiences a change in surface charge density over a pH range from 2.0 to 12.0 of at least 1%. The method comprises contacting the pH sensing material and the aqueous solution, illuminating the pH sensing material, and monitoring an optical signal generated through comparison of incident light and exiting light to determine the optical transmission, absorption, reflection, and/or scattering of the pH sensitive material. The optical signal of the pH sensitive material varies in response to the pH of the aqueous solution.

Ohodnicki, Jr., Paul R.↗

Nanoscale mass conveyors

A mass transport method and device for individually delivering chargeable atoms or molecules from source particles is disclosed. It comprises a channel; at least one source particle of chargeable material fixed to the surface of the channel at a position along its length; a means of heating the channel; and a means for applying an controllable electric field along the channel, whereby the device transports the atoms or molecules along the channel in response to applied electric field. In a preferred embodiment, the mass transport device will comprise a multiwalled carbon nanotube (MWNT), although other one dimensional structures may also be used. The MWNT or other structure acts as a channel for individual or small collections of atoms due to the atomic smoothness of the material. Also preferred is a source particle of a metal such as indium. The particles move by dissociation into small units, in some cases, individual atoms. The particles are preferably less than 100 nm in size.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cosmogenic 10Be constraints on deglacial snowline rise in the Southern Alps, New Zealand

We report geochronological dating of glacial landforms, such as terminal and lateral moraines, is useful for determining the extent and timing of past glaciation and for reconstructing the magnitude and rate of past climate changes. In the Southern Alps of New Zealand, well-dated glacial geomorphological records constrain the last glacial cycle across much of the Waitaki River basin (e.g. Ōhau, Pukaki, Tekapo) but its southern sector such as the Ahuriri River valley remains comparatively unconstrained. Recently, there has been debate on the scale and rapidity of mountain glacier retreat during the last glacial termination, particularly the 20–17 ka period in New Zealand. Missing from this debate is well-constrained equilibrium-line altitude (ELA) and associated temperature reconstructions, particularly over the period around 17 ka, which can help us to develop a more complete picture of how past temperature changes drove glacier retreat. Here we report the first glacial chronology dataset from the Last Glacial Maximum (LGM) and subsequent deglaciation from the Ahuriri River valley, Southern Alps, New Zealand (44°23'54"S, 169°39'48"E) based on 38 beryllium-10 ( 10 Be) surface-exposure ages from terminal moraine systems and glaciated bedrock situated at the lower and middle sections of the valley. Our results show that the former Ahuriri Glacier reached its maximum extent at 19.8 ± 0.3 ka, which coincides with the global Last Glacial Maximum. By 16.7 ± 0.3 ka, the glacier had retreat ~18 km up-valley suggesting at least ~43% glacier-length loss relative to its full LGM extent. This deglaciation was accompanied by the formation of a shallow proglacial lake. Using the accumulation area ratio (AAR) method, we estimate that the ELA was lower than present by ~880 m (~1120 m a.s.l.) at 19.8 ± 0.3 ka, and ~770 m lower (~1230 m a.s.l.) at 16.7 ± 0.3 ka. Applying an estimate for temperature lapse rate, this ELA anomaly implies that local air temperature was 5 ± 1 °C colder than present (1981–2010) at 19.8 ± 0.3 ka, while it was 4.4 ± 0.9 °C colder at 16.7 ± 0.3 ka, assuming no change in precipitation. The substantial glacier retreat in response to a relatively small accompanying increases in ELA (110 m) and temperature (0.6 °C) may have been a result of the high glacier-length sensitivity of this glacier system due to its low gradient of former ice surface. Our low warming estimate differs markedly from other deglaciation studies, specifically from Rakaia River valley, which reports a much larger temperature increase at the onset of the last deglaciation. This precisely-dated moraine record along with reconstructed ELA as proxies for atmospheric conditions, provides new insight into post LGM glacier behaviour and climate conditions in New Zealand.

58 GEOSCIENCES↗

A direct evidence of vibrationally delocalized response at ice surface

Surface-specific vibrational spectroscopic responses at isotope diluted ice and amorphous ice are investigated by molecular dynamics (MD) simulations combined with quantum mechanics/molecular mechanics calculations. The intense response specific to the ordinary crystal ice surface is predicted to be significantly suppressed in the isotopically diluted and amorphous ices, demonstrating the vibrational delocalization at the ordinary ice surface. The collective vibration at the ice surface is also analyzed with varying temperature by the MD simulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

INTER-DIGITAL CAPACITIVE SENSOR FOR EVALUATING CABLE INSULATION THROUGH JACKET

Interdigital capacitive (IDC) sensors have previously been used to measure cable-age/damage indicative dielectric properties of cable insulation when placed in direct contact with the insulation. Often cable insulation is covered by a polymer jacket precluding direct contact with the insulation. As part of a continuing program to develop and evaluate nondestructive examination methods that may be applied to cable condition assessment, an IDC to measure the effect of cable polymer dielectric change through a covering jacket has been developed. The IDC consists of two fork-like electrodes facing each other with the fork tines interspersed and separated by a small gap. On one electrode, the gap is 5 mm while on the other, the gap is 2 mm. Electric field depth-of-field penetrations are similar to the electrode gaps. The electrodes are printed on a flexible substrate that can be conformed to the outside jacketed surface of a cylindrical cable, with tines parallel to the cable axis. The electrodes are connected to a broad frequency-spectral impedance meter that senses the capacitance between the narrowly gapped electrode tines. This capacitance is known to vary as a function of the permittivity of any material in close proximity to the electrodes. For jacketed cable systems, the IDC response is dominated by the jacket but, by analyzing measurements from IDC sensors with different depths-of-field penetration into the cable under test, the influence of the cable jacket material (primarily influenced by the shallow-depth-of field IDC) can be separated from the deeper-depth-of-field IDC sensing the combined effects of both jacket and underlying insulation. No other NDE method is known that is capable of sensing insulation dielectric properties through an overlying jacket.

Cable NDE, Interdigital Capacitance, Insulation Pe↗

Computed tomography dose measurements with radiochromic films and a flatbed scanner

Gafchromic XR-QA films were developed for patient dosimetry in diagnostic radiology. A possible application of these films is the measurement of doses in computed tomography. In this study a method to evaluate the CTDI using Gafchromic XR-QA film and a flatbed scanner was developed and tested. Film samples were cut to dimensions of 6x170 mm{sup 2} in order to have an integration area similar to that of a pencil ionization chamber, with the possibility of changing the integration length. Prior to exposing these films to a computed tomography beam, the angular dependence of the film dose response was investigated by exposing film strips to a static x-ray beam at different angles in the range 0 deg. - 180 deg. A difference of 49% was found between the response with the axis beam parallel to the film surface (90 deg.) and with the axis beam perpendicular (0 deg. and 180 deg.). Integrating over a 360 deg. exposure like the one in computed tomography, a difference of less than 2% was estimated, which is comparable with the measurement error obtainable with XR-QA film. A calibration with a CT beam in the scout mode was performed and film strips were then exposed to single axial scans and to helical scans both in air and in phantoms. Two different types of flatbed scanners were used to read the film samples, a Microtek ScanMaker 9800XL scanner and an Epson Expression 10000 XL scanner, and the accuracy of the results were compared. For beam collimations above 10 mm differences between CTDI measured by film and CTDI measured by ionization chamber below 9% were found for the Epson scanner, with an average estimated error at 1 {sigma} level of 5%. For the Microtek scanner and for the same film samples, differences below 11% with an average error at 1 {sigma} level of 8% were founded. The 1 {sigma} uncertainty of the measured CTDI was provided by the method for each measurement, and it was shown that about the 95% of the differences between the CTDI measurements with radiochromic films and with the ionization chamber were below the estimated 2 {sigma} uncertainty, for both scanners. After an accurate calibration procedure and the consideration of the uncertainty associated with the measurement, Gafchromic XR-QA films can be used to evaluate the CTDI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geophysical signatures of soil AFFF contamination from spectral induced polarization and low field nuclear magnetic resonance methods

Few field methods are available for characterizing source zones contaminated with aqueous film forming foam (AFFF). Non-invasive geophysical characterization of AFFF source zone contamination in situ could assist with the delineation and characterization of these sites, allowing for more informed sampling regimes aimed at quantifying subsurface poly- and perfluoroalkyl substances (PFAS) contamination. In this study, we present initial results from the investigation of the sensitivity of two existing surface and borehole-deployable geophysical technologies, spectral induced polarization (SIP), and low field nuclear magnetic resonance (NMR), to soils impacted with AFFF. To investigate the sensitivity of these methods to AFFF-impacted soil, bench-scale column experiments were conducted on samples consisting of natural and synthetic soils and groundwater. While our findings do not show strong evidence of NMR sensitivity to soil PFAS contamination, we do find evidence that SIP has sufficient sensitivity to detect PFAS sorption to soils. This finding is based on evidence that AFFF constituents associated with the pore surface produce a measurable polarization response in both freshly contaminated synthetic soils and in soils historically impacted with AFFF.

54 ENVIRONMENTAL SCIENCES↗

A general approach to develop reduced order models for simulation of solid oxide fuel cell stacks

A reduced order modeling approach based on response surface techniques was developed for solid oxide fuel cell stacks. This approach creates a numerical model that can quickly compute desired performance variables of interest for a stack based on its input parameter set. The approach carefully samples the multidimensional design space based on the input parameter ranges, evaluates a detailed stack model at each of the sampled points, and performs regression for selected performance variables of interest to determine the responsive surfaces. After error analysis to ensure that sufficient accuracy is established for the response surfaces, they are then implemented in a calculator module for system-level studies. The benefit of this modeling approach is that it is sufficiently fast for integration with system modeling software and simulation of fuel cell-based power systems while still providing high fidelity information about the internal distributions of key variables. This paper describes the sampling, regression, sensitivity, error, and principal component analyses to identify the applicable methods for simulating a planar fuel cell stack.

Pan, Wenxiao↗

Bandgap tailoring of rutile TiO{sub 2}(110) via surface patterning with electron cyclotron resonance sputtering

Crystalline TiO{sub 2} nanodots have been formed on single crystal rutile TiO{sub 2}(110) surfaces via ion beam sputtering method by utilizing Ar ion beams from electron cyclotron resonance source. Nearly five times enhancement in absorbance of visible light, {approx}5 times increase in luminescence, and {approx}0.1 eV narrowing of bandgap are observed for nanodot-patterned surfaces, in the absence of any dopant material. Formation of crystalline rutile TiO{sub 2} nanodots and development of Ti interstitials on the TiO{sub 2}(110) surface, after ion beam sputtering, are responsible for these observations. Results suggest that these nanodot-patterned rutile TiO{sub 2} surfaces can become effective photocatalysts.

36 MATERIALS SCIENCE↗

A Method of Moments Wide Band Adaptive Rational Interpolation Method for High-Quality Factor Resonant Cavities

A new adaptive rational interpolation method is proposed to obtain the wideband frequency response of a resonant cavity simulated with the method of moments (MoM). This interpolation method uses both the Loewner matrix to construct a rational expression for the solution vector of MoM’s matrix system and an error estimator generated by the solution vectors and their derivatives. This error estimator is implemented in the adaptive procedure to gain a minimum set of frequencies and solution vectors required in the interpolation. The resulting set of frequencies and solution vectors is applied to interpolate other system variables, such as shielding effectiveness and input impedance. Here numerical results of a slotted cylindrical cavity supporting high-quality factor resonances are presented, showing that the new rational interpolation method is accurate and efficient in interpolating the complicated resonant response of the solution vector functions.

42 ENGINEERING↗

Genetic Signatures in the Envelope Glycoproteins of HIV-1 that Associate with Broadly Neutralizing Antibodies

A steady increase in knowledge of the molecular and antigenic structure of the gp120 and gp41 HIV-1 envelope glycoproteins (Env) is yielding important new insights for vaccine design, but it has been difficult to translate this information to an immunogen that elicits broadly neutralizing antibodies. To help bridge this gap, we used phylogenetically corrected statistical methods to identify amino acid signature patterns in Envs derived from people who have made potently neutralizing antibodies, with the hypothesis that these Envs may share common features that would be useful for incorporation in a vaccine immunogen. Before attempting this, essentially as a control, we explored the utility of our computational methods for defining signatures of complex neutralization phenotypes by analyzing Env sequences from 251 clonal viruses that were differentially sensitive to neutralization by the well-characterized gp120-specific monoclonal antibody, b12. We identified ten b12-neutralization signatures, including seven either in the b12-binding surface of gp120 or in the V2 region of gp120 that have been previously shown to impact b12 sensitivity. A simple algorithm based on the b12 signature pattern was predictive of b12 sensitivity/resistance in an additional blinded panel of 57 viruses. Upon obtaining these reassuring outcomes, we went on to apply these same computational methods to define signature patterns in Env from HIV-1 infected individuals who had potent, broadly neutralizing responses. We analyzed a checkerboard-style neutralization dataset with sera from 69 HIV-1-infected individuals tested against a panel of 25 different Envs. Distinct clusters of sera with high and low neutralization potencies were identified. Six signature positions in Env sequences obtained from the 69 samples were found to be strongly associated with either the high or low potency responses. Five sites were in the CD4-induced coreceptor binding site of gp120, suggesting an important role for this region in the elicitation of broadly neutralizing antibody responses against HIV-1.

59 BASIC BIOLOGICAL SCIENCES↗

Demonstration and Validation of a Portable Raman Sensor for In-Situ Detection and Monitoring of Perchlorate (ClO 4 - )

Costs for environmental analysis and monitoring are increasing at a rapid rate and represent a significant percentage of the total and future remedial expenses at many U.S. Department of Defense (DoD) contaminated sites. It has been reported that about 30 to 40% of the remediation budget is usually spent on long-term monitoring (LTM), of which a large percentage represents laboratory analytical costs. Energetics such as perchlorate (ClO 4 - ) are among the most frequently detected contaminants in groundwater and surface water at or near military installations due to their persistence and mobility. Currently, the standard protocol entails collecting samples in the field, packaging them, and shipping them overnight to a designated laboratory for analysis. This process requires significant sample preparation and handling, and analytical results may not be available for several days to weeks. In this project, we developed and demonstrated a portable Raman sensor based on surface enhanced Raman scattering (SERS) technology to detect ClO 4 - in contaminated water. We summarize major accomplishments as follows: • A SERS sensor based on elevated gold (Au) nano-ellipse dimer architectures was designed and developed for ClO 4 - with a detection limit of ~10 -6 M (or 100 μg/L); The performance of these sensors was evaluated and optimized through variation of their geometric characteristics (i.e., dimer aspect ratio, dimer separation, etc.). • Large-scale commercial production of SERS substrate sensors via nanoimprinting by Nanova Inc. and Nanoimprint lithography (NIL) technology was successfully demonstrated. This is a substantial step forward toward the commercialization of the SERS sensors and may potentially lead to significantly reduced fabrication costs of SERS substrates. • Commercially produced SERS sensors were demonstrated to detect ClO 4 - at levels above 10 -6 M using a portable Raman analyzer. The performance of the commercial SERS sensors for ClO 4 - detection in the presence and absence of interferences was determined for a series of standard solutions. Sulfate (SO 4 2- ) was found to exhibit the greatest interference for the anions tested, which included Cl-, NO 3 - , and SO 4 2- . • Field demonstration of the portable Raman sensor with commercially produced SERS substrates was completed at two Department of Defense (DoD) sites; twice at the Indian Head Naval Surface Warfare Center, Indian Head, MD, and once at Redstone Arsenal, Huntsville, AL. Multiple wells were sampled at both DoD sites, where a standard addition method was employed using the sensor to determine the ClO 4 - 4 - and possibly other energetics that are both important for environmental monitoring and of interest for national security. However, we point out that SERS technology is also prone to interferences due to its sensitivity and responses to other ionic species, such as NO 3 - , SO 4 2- , and dissolved organics or co-contaminants present in the groundwater, which could potentially mask the SERS signal of the target analyte (i.e., ClO 4 - ). As such, SERS analysis was subject to significant variations (e.g., ±20% or more), and its detection limit for ClO 4 - -8 M) and was substantially higher than what we anticipated from laboratory studies. However, despite these complications, the portable Raman sensor developed in this project could be used as a rapid screening tool for ClO 4 - at concentrations above 10 -6 M. Future studies are warranted to further develop the technology and to optimize its performance, and eventually to bring the technology to the market. With additional development and demonstration, the sensor has the potential to reduce analytical costs by eliminating shipping and typical costs associated with laboratory analysis. A cost savings of 30–45% may be realized during a typical sampling event and, more importantly, the technology could allow rapid turn-around of information to decision makers for site characterization and remediation.

47 OTHER INSTRUMENTATION↗

A miniature high frequency sphere probe

A spherical probe having five surface mounted silicon pressure sensors is described. The probe is 0.2 inches in diameter yielding a frequency response above 30 kHz. A scheme is described for retrieving from the five pressure signals the stagnation and static pressures, Mach number and flow angles in two planes. The calibrations forming the base for this procedure, obtained from steady state tests, are given in the form of polynomials in the two flow angles. A method for compensating the silicon pressure sensors for thermal effects is given. Typical data obtained in the MIT Blowdown Compressor are presented in raw form and after reduction to flow angles, Mach number and stagnation pressure.

Kerrebrock, J. L.↗

Compact Simultaneous-beam Optical Strain Measurement System, Phase 5

Recent advances on the laser speckle strain measurement system under development at NASA Lewis Research Center have resulted in a compact, easy-to-use measurement package having many performance improvements over previous systems. NASA has developed this high performance optical strain measurement system for high temperature material testing applications. The system is based on I. Yamaguchi's two-beam speckle-shift strain measurement theory, and uses a new optical design that allows simultaneous recording of laser speckle patterns. This design greatly improves system response over previous implementations of the two-beam speckle-shift technique. The degree of immunity to transient rigid body motions is no longer dependent on the data transfer rate. The system automatically calculates surface strains at a frequency of about 5 Hz using a high speed digital signal processor in a personal computer. This system is fully automated, and can be operated remotely. This report describes the designs and methods used by the system, and shows low temperature strain test results obtained from small diameter tungsten-rhenium and palladium-chrome wires.

Lant, Christian T.↗

Contact position sensor using constant contact force control system

A force control system (50) and method are provided for controlling a position contact sensor (10) so as to produce a constant controlled contact force therewith. The system (50) includes a contact position sensor (10) which has a contact probe (12) for contacting the surface of a target to be measured and an output signal (V.sub.o) for providing a position indication thereof. An actuator (30) is provided for controllably driving the contact position sensor (10) in response to an actuation control signal (I). A controller (52) receives the position indication signal (V.sub.o) and generates in response thereto the actuation control signal (I) so as to provide a substantially constant selective force (F) exerted by the contact probe (12). The actuation drive signal (I) is generated further in response to substantially linear approximation curves based on predetermined force and position data attained from the sensor (10) and the actuator (30).

Sturdevant, Jay↗

Sensitivity Analysis of Launch Vehicle Debris Risk Model

As part of an analysis of the loss of crew risk associated with an ascent abort system for a manned launch vehicle, a model was developed to predict the impact risk of the debris resulting from an explosion of the launch vehicle on the crew module. The model consisted of a debris catalog describing the number, size and imparted velocity of each piece of debris, a method to compute the trajectories of the debris and a method to calculate the impact risk given the abort trajectory of the crew module. The model provided a point estimate of the strike probability as a function of the debris catalog, the time of abort and the delay time between the abort and destruction of the launch vehicle. A study was conducted to determine the sensitivity of the strike probability to the various model input parameters and to develop a response surface model for use in the sensitivity analysis of the overall ascent abort risk model. The results of the sensitivity analysis and the response surface model are presented in this paper.

Gee, Ken↗