Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

In Vitro Sugar Interference Testing With Amperometric Glucose Oxidase Sensors

Background: Electrochemical enzymatic glucose sensors are intended to measure blood or interstitial fluid glucose concentrations. One class of these glucose sensors are continuous glucose monitors (CGMs), indicated for tracking and trending of glucose concentrations in interstitial fluid and as an adjunct to blood glucose testing. Currently approved CGMs employ a glucose oxidase (GOx) electrochemical detection scheme. Potential interfering agents can impact the accuracy of results obtained by glucose sensors, including CGMs. Methods: Seven sugars, seven sugar alcohols, and three artificial sweeteners were in vitro screened for interference with amperometric glucose oxidase (GOx) sensors at concentrations greater than physiologic concentrations. Galactose was investigated further at physiologically relevant concentrations using a custom amperometric system. Furthermore, glucose and galactose calibration experiments were conducted to facilitate multiple enzyme kinetic analysis approaches (Michaelis-Menten and Hill equation) to understand the potential source and mechanism of interference from galactose. Results: Under in vitro testing, except for galactose, xylose and mannose, all screened compounds exhibited interference bias, expressed in mean absolute relative difference (MARD), of ⩽ 20% even at concentrations significantly higher than normal physiologic concentrations. Galactose exhibited, CGM-dependent, MARD of 47-72% and was subjected to further testing. The highest recorded mean relative difference (MRD) was 6.9 ± 1.3% when testing physiologically relevant galactose concentrations (0.1-10 mg/dL). Enzyme kinetic analysis provided calculations of maximum reaction rates ([Formula: see text]), apparent Michaelis constants ([Formula: see text]), and Hill equation h parameters for glucose and galactose substrates for the enzymes in the CGMs. Conclusion: Under the conditions of in vitro screening, 14 of the 17 compounds did not exhibit measuarable interference. Galactose exhibited the highest interference during screening, but did not substantially interfere with CGMs under the conditions of in vitro testing at physiologically relevant concentrations. Enzyme kinetic analysis conducted with galactose supported the notion that (1) the reactivity of GOx enzyme toward nonglucose sugars and (2) the presence of enzymatic impurities (such as galactose oxidase) are two potential sources for sugar interference with GOx glucose sensors, and thus, should be considered during device development.

Boehm, Ryan↗

R&D for new silicon pixel sensors for the High Luminosity phase of the CMS experiment at LHC

The High Luminosity upgrade of the CERN LHC collider (HL-LHC) demands a new high-radiation–tolerant solid-state pixel sensor capable of surviving fluencies up to a few 10$^{16} n_{eq}/\mathrm{cm}^2$ at ~ 3 cm from the interaction point. To this extent the INFN ATLAS-CMS joint research activity, in collaboration with Fondazione Bruno Kessler (FBK), is aiming at the development of thin n -in- p –type pixel sensors for the HL-LHC. The R&D covers both planar and single-sided 3D columnar pixel devices made with the Si-Si Direct Wafer Bonding technique, which allows for the production of sensors with 100 μm and 130 μm active thickness for planar sensors, and 130 μm for 3D sensors, the thinnest ones ever produced so far. The first prototypes of hybrid modules, bump-bonded to the present CMS readout chip, have been tested on beam. The first results on their performance before and after irradiation are presented

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chem/bio wearable sensors: current and future direction

Abstract Examples of existing and emerging wearable sensors for chemical and biological threat agents are reviewed and essential enabling developments identified. Wearables are described as inward looking sensors (self-monitoring) and outward looking sensors (environmental sensors). The future potential for wearable sensors, expected capabilities, and key challenges are summarized.

wearables, Chemical Weapons Agent Detection, Bioth↗

Yakima River Basin Temporal Study: Sensor and Sample Data from Wenas Creek following the Evans Canyon Fire in Washington, USA

The Evans Canyon Fire occurred in Washington in August 2020 and burned 76,000 acres of the semi-arid shrub-steppe landscape at low to moderate severities. This fire burned across the Wenas Creek watershed, allowing for a sampling design that included a portion of the stream within the burned area and a reference site upstream of the burn. Monthly data was collected at an unburned (W10) and burned (W20) site from November 2020 to August 2022 for in situ hydrological and water chemistry sensor data, handheld sensor water chemistry data, general environmental context photos, and field metadata. This dataset is comprised of one folder with field photos and one main data folder containing (1) sensor and sample field protocols; (2) file-level metadata (flmd); (3) data dictionary (dd); (4) international geo-sample number (IGSN) mapping file; (5) field metadata; (6) readme; (7) methods codes; (8) dissolved organic carbon (DOC; measured as non-purgeable organic carbon; NPOC); (9) total nitrogen (TN); (10) total suspended solids (TSS); (11) sensor data (specific conductance, pH, total dissolved solids, temperature, pressure, dissolved oxygen, and turbidity) averages; and (12) sensor installation methods. All files are .csv, .jpg, .jpeg, or .pdf.

54 ENVIRONMENTAL SCIENCES↗

Pulse Tube Interference in Cryogenic Sensor Resonant Circuits (Final Paper)

Transition edge sensors (TES) are extremely sensitive superconducting sensors, operating at 100 mK, which can be used to detect X-rays and Cosmic Microwave Background. The goal of our project is to design the electronics to read out an array of 10000 of these sensors by using microwave signals. However, we noticed the pulse tube used to maintain cryogenic temperatures caused interference in our readout. To determine the cause of the signal distortions, we used a detector with a 370 MHz sampling rate to collect and analyze sensor data. Although this data provided little information towards the nature of the noise, it was determined through a maintenance procedure than the 0.3 mm stainless steel wires were being vibrated due to acoustic waves, which distorted the signal. Replacing this wire appeared to cease the interference from the sensor data.

42 ENGINEERING↗

Pulse Tube Interference in Cryogenic Sensors - Oral Presentation [Slides]

Transition edge sensors (TES) are extremely sensitive superconducting sensors, operating at 100 mK, which can be used to detect X-rays and Cosmic Microwave Background. The goal of our project is to design the electronics to read out an array of 10000 of these sensors by using microwave signals. However, we noticed the pulse tube used to maintain cryogenic temperatures caused interference in our readout. To determine the cause of the signal distortions, we used a detector with a 370 MHz sampling rate to collect and analyze sensor data. Although this data provided little information towards the nature of the noise, it was determined through a maintenance procedure than the 0.3 mm stainless steel wires were being vibrated due to acoustic waves, which distorted the signal. Replacing this wire appeared to cease the interference from the sensor data.

47 OTHER INSTRUMENTATION↗

Multifunctional Integrated Sensors (MFISES)

Many emerging IoT applications require sensing of multiple physical and environmental parameters for: completeness of information, measurement validation, unexpected demands, improved performance. For example, a typical outdoor weather station measures temperature, humidity, barometric pressure, light intensity, rainfall, wind speed and direction. Existing sensor technologies do not directly address the demand for cost, size, and power reduction in multi-paramater sensing applications. Industry sensor manufacturers have developed integrated sensor systems for inertial measurements that combine accelerometers, gyroscopes, and magnetometers, but do not address environmental sensing functionality. In existing research literature, a technology gap exists between the functionality of MEMS sensors and the real world applications of the sensors systems.

42 ENGINEERING↗

Commercializing Wide Range Sensor

The purpose of the CRADA was to allow Sandia National Laboratories (Sandia) to assist H2Scan Corporation, in the transfer of the Wide Range Hydrogen Sensor (WRS) to commercial applications. The overall goal was to develop a very stable, low-cost hydrogen (H 2 ) sensor that functioned in the complex environments of H 2 production facilities, petrochemical plants, power plants, and in the H 2 transportation economy. This project has resulted in improved H 2 sensor performance with greater resistance to the contaminants found in these environments than possible previously. Benefits include: improved H2 sensor performance, new markets and improved competitive position for H2scan, greater chemical sensor expertise and a more robust chemical testing capability at Sandia that can be applied to DOE’s nuclear weapons mission, and job creation and economic development for the public.

08 HYDROGEN↗

Distributed Fiber Optic Sensor for On-Line Monitoring of Coal Gasifier Refractory Health

This report summarizes technical progress on the program “Distributed Fiber Optic Sensor for On-Line Monitoring of Coal Gasifier Refractory Health,” funded by the National Energy Technology Laboratory of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The scope of work entails analyses of traveling grating generation technologies in an optical fiber, as well as the interrogation of the gratings to infer a distributed temperature along the fiber, for the purpose of developing a real-time refractory health condition monitoring technology for coal gasifiers. During the project period, which is from 2011-2015, three different sensing principles were studied, including four-wave mixing (FWM), coherent optical time-domain reflectometer (C-OTDR) and Brillouin optical time-domain analysis (BOTDA). By comparing the three methods, the BOTDA was selected for further development into a complete bench-top sensing system for the proposed high-temperature sensing application. Based on the input from Eastman Chemical, the industrial collaborator on this project, a cylindrical furnace was designed and constructed to simulate typical gasifier refractory temperature conditions in the laboratory, and verify the sensor’s capability to fully monitor refractory conditions on the back-side at temperatures up to 1000°C. In the later stages of the project, the sensing system was tested in the simulated environment for its sensing performance and high-temperature survivability. Through theoretical analyses and experimental research on the different factors affecting the sensor performance, a sensor field deployment strategy was proposed for possible future sensor field implementations.

01 COAL, LIGNITE, AND PEAT↗

Development of Self-Powered Wireless-Ready High Temperature Electrochemical Sensors for In-Situ Corrosion Monitoring for Boiler Tubes in Next Generation Coal-based Power Systems

The key innovation of this project is the synergy of the high temperature sensor technology based on the science of electrochemical measurement and state-of-the-art wireless communication technology. A novel self-powered wireless high temperature electrochemical sensor system has been developed for coal-fired boilers used for power generation. An initial prototype of the in-situ sensor demonstrated the capability of the wireless communication system in the laboratory and in a pilot plant (Industrial USC Boiler Setting) environment to acquire electrochemical potential and current signals during the corrosion process. Uniform and localized under-coal ash deposit corrosion behavior of Inconel 740 superalloy has been studied at different simulated coal ash hot corrosion environments using the developed sensor. Two typical potential noise patterns were found to correlate with the oxidation and sulfidation stages in the hot coal ash corrosion process. Two characteristic current noise patterns indicate the extent of the corrosion. There was a good correlation between the responses of electrochemical test data and the results from corroded surface analysis. Wireless electrochemical potential and current noise signals from a simulated coal ash hot corrosion process were concurrently transmitted and recorded. The results from the performance evaluation of the sensor confirm a high accuracy in the thermodynamic and kinetic response represented by the electrochemical noise and impedance test data.

47 OTHER INSTRUMENTATION↗

Demonstration of a prototype hydrogen sensor and electronics package

This is a progress report for the demonstration of a prototype hydrogen sensor and electronics package. There are five tasks associated with this, and four have been completed as of August 2016: Station Demonstration and Site Recommendation, Order Sensor Equipment, Build Sensors, and Install Sensors. The final task to be completed is Sensor Demonstration and Data Analysis, and expected completion date is January 26, 2017. This progress report details each of the tasks and goes into detail about what is currently being worked on, along with the budget and planned work for July 27, 2016 to January 26, 2017.

36 MATERIALS SCIENCE↗

Biases of the MET Temperature and Relative Humidity Sensor (HMP45) Report

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility Data Quality (DQ) Office was alerted to a potential bias in the surface meteorological instrumentation (MET) temperature when compared with a nearby Mesonet station. This led to an investigation into this problem that was expanded to include many of the other extended facilities (EF) and both the temperature and relative humidity (RH) variables. For this study, the Mesonet was used as the standard reference due to results that showed an increased accuracy in high-humidity environments along with the fact that the Mesonet had previous documented a problem with the HMP45C sensors. Some differences between the sites were taken into account during the analysis: 1. ARM MET sensors were upgraded from an HMP35 to an HMP45 throughout 2007 2. Mesonet switched to aspirated shields in 2009 – To mitigate the differences between aspirated and non-aspirated measurements, data were only analyzed when the wind speed was higher than 3 m/s. This reduced the uncertainty for the non-aspirated measurements from 1.51 ºC to 0.4 ºC. 3. ARM MET is mounted 0.5m higher than the Mesonet station (2.0m versus 1.5m) – This is assumed to have a negligible effect on the differences. 4. Sites were not co-located – For some locations, the distances between sites were as much as 45 km. As part of the investigation into the differences, the Mesonet had reported that the HMP45 sensors had a low-temperature bias in high-humidity environments. This was verified at two different sites where the ARM measurements were compared with the Mesonet measurements. The Mesonet provided redundant temperature measurements from two different sensors at each site. These measurements compared fairly well, while the ARM sensor showed a bias overnight when the humidities were higher. After reviewing the yearly average differences in the data and analyzing the RH data during fog events when we assume it should be 100%, we determined that a majority of the sites have a bias in the RH compared to the Mesonet sites, but that only a few sites show a bias in the temperature measurements that are outside the range of instrument uncertainties. We note that there can be a lot of variability across some of the distances between the MET and Mesonet sites and these biases reported herein should not be used as offsets.

47 OTHER INSTRUMENTATION↗

Hyperspectral Sensors Final Report CRADA No. TC02173.0

This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Science Applications International Corporation (SAIC), National Security Space Operations/SRBU, to develop longwave infrared (LWIR) hyperspectral imaging (HSI) sensors for airborne and potentially ground and space, platforms. LLNL has designed and developed LWIR HSI sensors since 1995. The current generation of these sensors has applications to users within the U.S. Department of Defense and the Intelligence Community. User needs are for multiple copies provided by commercial industry. To gain the most benefit from the U.S. Government’s prior investments in LWIR HSI sensors developed at LLNL, transfer of technology and know-how from LLNL HSI experts to commercial industry was needed. The overarching purpose of the CRADA project was to facilitate the transfer of the necessary technology from LLNL to SAIC thereby allowing the U.S. Government to procure LWIR HSI sensors from this company.

47 OTHER INSTRUMENTATION↗

Tunable Impedance Spectroscopy Sensors via Selective Nanoporous Materials.

Impedance spectroscopy was leveraged to directly detect the sorption of I 2 by selective adsorption into nanoporous metal organic frameworks (MOF). Films of three different types of MOF frameworks, respectively, were drop cast onto platinum interdigitated electrodes, dried, and exposed to gaseous I 2 at 25, 40, or 70 C. The MOF frameworks varied in topology from small pores (equivalent to I 2 diameter) to large pore frameworks. The combination of the chemistry of the framework and pore size dictated quantity and kinetics of I 2 adsorption. Air, argon, methanol, and water were found to produce minimal changes in ZIF-8 impedance. Independent of MOF framework characteristics, all resultant sensors showed high response to I 2 in air. As an example of sensor output, I 2 was readily detected at 25 C in air within 720 s of exposure, using an un-optimized sensor geometry with a small pored MOF. Further optimization of sensor geometry, decreasing MOF film thicknesses and maximizing sensor capacitance, will enable faster detection of trace I 2 .

47 OTHER INSTRUMENTATION↗

Chaparral Model 60 Infrasound Sensor Evaluation.

Sandia National Laboratories has tested and evaluated an infrasound sensor, the Model 60 manufactured by Chaparral Physics, a Division of Geophysical Institute of the University of Alaska, Fairbanks. The purpose of the infrasound sensor evaluation was to determine a measured sensitivity, transfer function, power, self-noise, dynamic range, and seismic sensitivity. The Model 60 infrasound sensor is a new sensor developed by Chaparral Physics intended to be a small, rugged sensor used in more flexible application conditions.

47 OTHER INSTRUMENTATION↗

Embedded Sensors and Controls to Improve Component Performance and Reliability - Final Report

Oak Ridge National Laboratory has researched embedded instrumentation and controls (I&C) for extreme environments under the Department of Energy, Office of Nuclear Energy's Nuclear Energy Enabling Technology program. Advanced sensors and controls have the potential to dramatically increase the performance and efficiency of nuclear reactor components, however, the extreme environments of exiting and advanced reactor designs limit the options for sensors, actuators, and control designs. To address two of the extreme environment challenges to embedded I&C, the focus of this research is to fill technology gaps needed for electromagnetic systems that can operate at temperatures greater than 700 C in corrosive environments. A magnetically suspended, canned-rotor pump was chosen for the embedded I&C development platform because it is a system with a practical need in industry and because the sensors, actuators, and embedded I&C technologies needed to successfully build this platform will be widely applicable to any high-temperature components that utilize electromagnetic interactions. This design also eliminates the need for pump seals and mechanical bearings which are the main sources of pump failures and maintenance costs. During the project a conceptual design for the high-temperature magnetically suspended pump was developed and analyzed for manufacturability and reliability. Specifications for the materials, control system, sensors, mechanical performance, high-temperature wiring, and electromagnetic properties were developed for the conceptual design. The canned rotor design of the high-temperature pump presents unique fluid force characteristics arising from the thin fluid channel between the rotor and stator. A model of the fluid forces was developed and the impact of these forces on the stability and performance of magnetic bearing controllers was studied. Then a room temperature bench-scale magnetic testbed was designed and fabricated for testing the performance of sensors and electromagnetic actuators, modern control design techniques, closed-loop system identification, state estimation, and model uncertainty. Finally, a loop-scale testbed with submerged magnetic bearings was designed and fabricated. This testbed will be used to analyze the stability and performance of control system designs in response to the nonlinear and cross-coupling fluid effects between the shaft axes of motion, rotordynamics, gyroscopic effects, and impeller disturbances.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Contact Stress Sensor _ Proposal to the FY2020 Technology Tech Mat Grants Program

The technology to be advanced is a very small and thin Contact Stress Sensor (CSS) that measures the contact stress between two contacting surfaces. It will be used to monitor the internal condition of a weapon in the stockpile over periods of decades. Monitoring the load path of a complex weapon assembly offers an important verification of the weapon’s mechanical state in both quasi-static or dynamic environments. Concurrently, the sensor can be used to measure temperature. This is useful for sensor calibration while installed in a system, as well as thermal monitoring in regions of the system that are difficult to access. Thus, the CSS is one way to monitor the internal “health” of a weapon. A sensor is shown below with each sensor being less then 2mm in width and 125 microns in thickness.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Developing Fugitive Emissions Sensor Networks

This document summarizes research performed under the Laboratory Directed Research and Development (LDRD) project titled Developing Fugitive Emissions Sensor Networks: New Optimization Algorithms for Monitoring, Measurement and Verification. The purpose of this project is to develop methods and software to enhance detection programs through optimal design of the sensor network. This project includes both software development and field work. While this project is focused on methane emissions, the sensor placement optimization framework can be applied to a wide range of applications, including the placement of water quality sensors, surveillance cameras, fire and chemical detectors. This research has the potential to improve national security by improving the way sensors are deployed in the field.

47 OTHER INSTRUMENTATION↗