Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

EGS Collab Experiment 1: 3D Seismic Velocity Model and Updated Microseismic Catalog from Double-Difference Seismic Tomography

This package contains a 3D Seismic velocity model and an updated microseismic catalog obtained for a double-difference seismic tomography study. The 3D_seismic_velocity_model text file contains x (m), y(m), z(m), P-wave velocity (km/s), P-wave velocity quality indicator (1 for well-constrained; 0 for poorly constrained), S-wave velocity (km/s), and S-wave velocity quality indicator (1 for well-constrained; 0 for poorly constrained). The Updated_MEQ_catalog text file contains event origin time, x(m), y(m), z(m), error in x (m), error in y (m), error in z (m), and RMS misfit (millisecond). The 3D_seismic_P-wave_velocity_model animation file shows slices of the 3D P-wave velocity model. The 3D_seismic_S-wave_velocity_model animation file shows slices of the 3D S-wave velocity model. The Interactive_MEQ_location_comparison API file is an interactive visualization of the updated microseismic event locations and the original seismic catalog. The visualization allows users to view and compare the event locations by dragging, rotating, and zooming in. An updated version of 3D_seismic_velocity_model and associated animations were included, which were calculated with a more strict assumption for quality indicators.

15 GEOTHERMAL ENERGY↗

Tidal Resource Data from Sequim Bay Inlet, WA, August 2020

Data from a Nortek Signature1000 deployed on a lander for 14 days in Aug 2020 in the entrance to Sequim Bay, WA. Raw data were processed using the DOLfYN python package and standardized using the ME Data Pipeline python package, tsdat version 0.2.12. Processed data were partitioned into 24 hour increments and saved in the NETCDF file format.

16 TIDAL AND WAVE POWER↗

Building a 40% Energy Saving House in the Mixed-Humid Climate

This report describes a home that uses 40% less energy than the energy-efficient Building America standard - a giant step in the pursuit of affordable near-zero-energy housing through the evolution of five near-zero-energy research houses. This four-bedroom, two-bath, 1232-ft2 house has a Home Energy Rating System (HERS) index of 35 (a HERS rating of 0 is a zero-energy house, a conventional new house would have a HERS rating of 100), which qualifies it for federal energy efficiency and solar incentives. The house is leading to the planned construction of a similar home in Greensburg, Kansas, and 21 staff houses in the Walden Reserve, a 7000-unit "deep green" community in Cookville, Tennessee. Discussions are underway for construction of similar houses in Charleston, South Carolina, Seattle, Washington, Knoxville and Oak Ridge, Tennessee, and upstate New York. This house should lead to a 40% and 50% Gate-3, Mixed-Humid-Climate Joule for the DOE Building America Program. The house is constructed with structurally-insulated-panel walls and roof, raised metal-seam roof with infrared reflective coating, airtight envelope (1.65 air changes per hour at 50 Pascal), supply mechanical ventilation, ducts inside the conditioned space, extensive moisture control package, foundation geothermal space heating and cooling system, ZEHcor wall, solar water heater, and a 2.2 kWp grid-connected photovoltaic (PV) system. The detailed specifications for the envelope and the equipment used in ZEH5 compared to all the houses in this series are shown in Tables 1 and 2. Based on a validated computer simulation of ZEH5 with typical occupancy patterns and energy services for four occupants, energy for this all-electric house is predicted to cost only $0.66/day ($0.86/day counting the hookup charges). By contrast, the benchmark house would require $3.56/day, including hookup charges (these costs are based on a 2006 residential rates of $0.07/kWh and solar buyback at $0.15/kWh). The solar fraction for this home located in Lenoir City, Tennessee, is predicted to be as high as 41%(accounting for both solar PV and the solar water heater). This all-electric home is predicted to use 25 kWh/day based on the one year of measured data used to calibrate a whole-building simulation model. Based on two years of measured data, the roof-mounted 2.2 kWp PV system is predicted to generate 7.5 kWh/day. The 2005 cost to commercially construct ZEH5, including builder profit and overhead, is estimated at about $150,000. This cost - for ZEH5's panelized construction, premanufactured utility wall (ZEHcor), foundation geothermal system, and the addition of the walkout lower level, and considering the falling cost for PV - suggests that the construction cost per ft2 for a ZEH5 two-story will be even more cost-competitive. The 2005 construction cost estimate for a finished-out ZEH5 with 2632 ft2 is $222,000 or $85/ft2. The intention of this report is to help builders and homeowners make the decision to build zero-energy-ready homes. Detailed drawings, specifications, and lessons learned in the construction and analysis of data from about 100 sensors monitoring thermal performance for a one-year period are presented. This information should be specifically useful to those considering structural insulated panel walls and roof, foundation geothermal space heating and cooling, solar water heater and roof-mounted, photovoltaic, grid-tied systems.

14 SOLAR ENERGY↗

Deep Residential Retrofits in East Tennessee

Executive Summary Oak Ridge National Laboratory (ORNL) is furthering residential energy retrofit research in the mixed-humid climate of East Tennessee by selecting 10 homes and guiding the homeowners in the energy retrofit process. The homeowners pay for the retrofits, and ORNL advises which retrofits to complete and collects post-retrofit data. This effort is in accordance with the Department of Energy s Building America program research goal of demonstrating market-ready energy retrofit packages that reduce home energy use by 30 50%. Through this research, ORNL researchers hope to understand why homeowners decide to partake in energy retrofits, the payback of home energy retrofits, and which retrofit packages most economically reduce energy use. Homeowner interviews help the researchers understand the homeowners experience. Information gathered during the interviews will aid in extending market penetration of home energy retrofits by helping researchers and the retrofit industry understand what drives homeowners in making positive decisions regarding these retrofits. This report summarizes the selection process, the pre-retrofit condition, the recommended retrofits, the actual cost of the retrofits (when available), and an estimated energy savings of the retrofit package using EnergyGauge . Of the 10 households selected to participate in the study, only five completed the recommended retrofits, three completed at least one but no more than three of the recommended retrofits, and two households did not complete any of the recommended retrofits. In the case of the two homes that did none of the recommended work, the pre-retrofit condition of the homes and the recommended retrofits are reported. The five homes that completed the recommended retrofits are monitored for energy consumption of the whole house, appliances, space conditioning equipment, water heater, and most of the other circuits with miscellaneous electric loads (MELs) and lighting. Thermal comfort is also monitored, with temperature and humidity measured in all conditioned zones, attics, crawlspaces, and unconditioned basements. In some homes, heat flux transducers are installed on the basement walls to help determine the insulating qualities of the technologies and practices. EnergyGauge is used to estimate the pre-retrofit and post-retrofit home energy rating system (HERS) index and reduction in energy consumption and energy bill. In a follow-up report, data from the installed sensors will be presented and analyzed as well as a comparison of the post-retrofit energy consumption of the home to the EnergyGauge model of the post-retrofit home. Table ES1 shows the retrofits that were completed at the eight households where some or all of the recommended retrofits were completed. Home aliases are used to keep the homeowners anonymous. Some key findings of this study thus far are listed as follows. Some homeowners (50%) are not willing to spend the money to reach 30 50% energy savings. Quality of retrofit work is significantly variable among contractors which impact the potential energy savings of the retrofit. Challenges exist in defining house volume and floor area. Of the five homes that completed all the recommended retrofits, energy bill savings was not the main driver for energy retrofits. In no case were the retrofits cost neutral given a 15 year loan at 7% interest for the retrofit costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Performance Homes That Use 50% Less Energy Than the DOE Building America Benchmark Building

This document describes lessons learned from designing, building, and monitoring five affordable, energy-efficient test houses in a single development in the Tennessee Valley Authority (TVA) service area. This work was done through a collaboration of Habitat for Humanity Loudon County, the US Department of Energy (DOE), TVA, and Oak Ridge National Laboratory (ORNL).The houses were designed by a team led by ORNL and were constructed by Habitat's volunteers in Lenoir City, Tennessee. ZEH5, a two-story house and the last of the five test houses to be built, provided an excellent model for conducting research on affordable high-performance houses. The impressively low energy bills for this house have generated considerable interest from builders and homeowners around the country who wanted a similar home design that could be adapted to different climates. Because a design developed without the project constraints of ZEH5 would have more appeal for the mass market, plans for two houses were developed from ZEH5: a one-story design (ZEH6) and a two-story design (ZEH7). This report focuses on ZEH6, identical to ZEH5 except that the geothermal heat pump is replaced with a SEER 16 air source unit (like that used in ZEH4). The report also contains plans for the ZEH6 house. ZEH5 and ZEH6 both use 50% less energy than the DOE Building America protocol for energyefficient buildings. ZEH5 is a 4 bedroom, 2.5 bath, 2632 ft2 house with a home energy rating system (HERS) index of 43, which qualifies it for federal energy-efficiency incentives (a HERS rating of 0 is a zero-energy house, and a conventional new house would have a HERS rating of 100). This report is intended to help builders and homeowners build similar high-performance houses. Detailed specifications for the envelope and the equipment used in ZEH5 are compared with the Building America Benchmark building, and detailed drawings, specifications, and lessons learned in the construction and analysis of data gleaned from 94 sensors installed in ZEH5 to monitor electric sub-metered usage, temperature and relative humidity, hot water usage, and heat pump operation for 1 year are presented. This information should be particularly useful to those considering structural insulated panel (SIP) walls and roofing; foundation geothermal heat pumps for space heating and cooling; solar water heaters; and roof-mounted, grid-tied photovoltaic systems. The document includes plans for ZEH6 (adapted from ZEH5), a one-story, high-performance house, as well as projections of how the design might perform in five major metropolitan areas across the TVA service territory. The HERS ratings for this all-electric house vary from 36 (Memphis, Tennessee) to 46 (Bristol, Tennessee).

14 SOLAR ENERGY↗

INL Control System Situational Awareness Technology Final Report 2013

The Situational Awareness project is a comprehensive undertaking of Idaho National Laboratory (INL) in an effort to produce technologies capable of defending the country’s energy sector infrastructure from cyber-attack. INL has addressed this challenge through research and development of an interoperable suite of tools that safeguard critical energy sector infrastructure. The technologies in this project include the Sophia Tool, Mesh Mapper (MM) Tool, Intelligent Cyber Sensor (ICS) Tool, and Data Fusion Tool (DFT). Each is designed to function effectively on its own, or they can be integrated in a variety of customized configurations based on the end user’s risk profile and security needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Embedding Sensors During Additive Manufacturing

This PowerPoint presentation had the following headings: Fused deposition modeling (FDM); Open source 3D printing; Objectives; Vibration analysis; Equipment; Design; Material choices; Failure causes, such as tension, bubbling; Potential solutions; Simulations; Embedding the sensors; LabView programming; Alternate data acquisition; Problem and proposed solution; and, Conclusions

42 ENGINEERING↗

Basic Research Needs for Microelectronics

Since the invention of the integrated circuit in 1958, advances in microelectronics have followed Moore’s law and other scaling laws. These have led to over a billion-fold increase in the number of transistors on a chip. The Department of Energy’s Office of Science (DOE-SC) programs have always been at the cutting edge of microelectronics, making major contributions to the scientific understanding, materials, and advanced instrumentation that enabled innovations to promote scaling. This has driven transformative advances in microelectronics for the challenging demands of DOE’s high performance computing and science facilities. Now, strong evidence exists that scaling is approaching its physical and economic limits, and yet, the growth of data-centric computing and sensor networks is redefining computing workloads and microelectronics needs. In addition, greatly improved microelectronics are needed for the nation’s electricity grid if it is to be energy-efficient, resilient to natural phenomena and intentional attack, and agile in adapting to fluctuations in demand and power generation. Sustained and rapid progress in microelectronics science and technology from millivolt to megavolt scales is thus essential if we are to continue pushing the boundaries of science within DOE, and more significantly, to continue to lead the global information and power technology revolution. In October 2018, DOE-SC convened a workshop to address Basic Research Needs for Microelectronics by a “co-design” approach. Participants focused on scientific issues associated with advanced microelectronics technologies for applications relevant to the DOE mission, including computing, power grid management, and science facility workloads. (Topics of direct relevance to quantum information science and quantum computing were outside the scope of this workshop.) The workshop was organized around microelectronics needs for three areas: 1) future DOE-SC facilities, 2) high performance computing beyond exascale (a billion billion calculations per second), and 3) power control, conversion, and detection for a modernized electrical grid and related high power applications. Panels were formed around each of these areas, with a fourth panel formed to address Crosscutting Research. Workshop participants were asked to focus on a co-design innovation ecosystem in which materials, chemistries, devices, systems, architectures, algorithms, and software are researched and developed in a closely integrated fashion, with feedback and interdisciplinary collaboration at each interface in this microelectronics technology hierarchy. The panels identified the five Priority Research Directions on the following page.

36 MATERIALS SCIENCE↗

An Authentication Vulnerability Assessment of Connected Lighting Systems

Emerging connected lighting systems (CLS) that incorporate distributed intelligence, network interfaces, and sensors can become data-collection platforms that enable a wide range of valuable new capabilities as well as greater energy savings in buildings and cities. However, CLS technology is currently at an early stage of development, and its increased connectivity introduces cybersecurity risks that are new to the lighting industry and that must be addressed for successful integration with other systems. While a number of existing frameworks, guidelines, and tests for evaluating cybersecurity vulnerability may apply to CLS in whole or in part, there is currently no mandatory requirement for cybersecurity testing or certification. The lighting industry, including technology developers and specification organizations, is currently evaluating the suitability of existing frameworks and guidelines for CLS. To support these efforts, Pacific Northwest National Laboratory (PNNL) is conducting a series of studies intended to educate lighting industry stakeholders on specific cybersecurity practices and characterize their implementation in commercially available CLS with varying system architectures, network-communication technologies, and degrees of maturity. This study demonstrates that tests for authentication vulnerabilities can be developed with objective pass/fail criteria, therby facilitating comparisons between CLS. Based on the limited results of this study, it appears that the CLS that are being brought to market have varying levels of authentication vulnerability. It is hoped that these evaluations will support and perhaps accelerate industry discussions on the risks of specific security vulnerabilities, what vulnerabilities should be addressed by in-development of future lighting-specific best practices, and whether any such practices should be included in voluntary lighting standards.

42 ENGINEERING↗

EdgeAI: How to Use AI to Collect Reliable and Relevant Watershed Data

Focal Area(s): Focal areas are on data acquisition and assimilation enabled by AI, advanced methods including experimental/network design/optimization, unsupervised learning (including deep learning), and hardware-related efforts involving AI (e.g., edge computing). Science Challenge: The transformational science challenge that we address is the following: – Ensuring, in near real-time, that the data collected from distributed sensor networks is accurate and contains useful information to identify, quantify, and predict watershed and ecosystem dynamic responses to short- and long-term perturbations.

54 ENVIRONMENTAL SCIENCES↗

Artificial Intelligence for Multiphysics Nuclear Design Optimization with Additive Manufacturing

The geometric flexibility of additively manufactured metals and ceramics generates a very large and open design space that requires advanced modeling and simulation tools for physics simulations and the rigorous definition of design problems. This effort deploys artificial intelligence (AI) and machine learning (ML) algorithms to understand the design space, evaluate potential designs, and more efficiently generate optimized results. The Transformational Challenge Reactor (TCR) program is leveraging advances in several scientific areas—including materials, manufacturing, sensors and control systems, data analytics, and high-fidelity modeling and simulation—to accelerate the design, manufacturing, qualification, and deployment of advanced nuclear energy systems. Through a manufacturing-informed design approach, the TCR program seeks to integrate digital data for rapid nuclear innovation; accelerate the adoption of advances in manufacturing, materials, and computational sciences for nuclear applications; and dramatically reduce deployment costs and timelines for new nuclear reactor technologies. This report documents efforts under the TCR program to leverage advanced modeling and simulation techniques driven by AI/ML algorithms on high-performance computing (HPC) systems to yield more optimized TCR core designs. A multiphysics ML surrogate model was developed to run on the HPC architectures. The surrogate model is trained on high-fidelity simulation data of coupled neutronics and thermofluidics and is used to quickly evaluate thousands of candidate core designs in parallel, which drives the evolution of the cooling channel shapes to minimize temperature peaking and material stress. Outcomes from these activities provide design information and feedback into the core design efforts.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Cloud-based Application to Enable a Scalable Risk-informed Predictive Maintenance Strategy at Nuclear Power Plants

Light-water reactor operations and maintenance (O&M) costs are prohibitively high, thus contributing to the premature decommissioning of nuclear power plants (NPPs). This is partly due to how the equipment is monitored. In recent years, cloud computing has emerged as a dominant technology by virtue of its low costs, computing and storage adaptability, and ability to host applications over numerous types of virtual infrastructures. Cloud computing can be a cost-effective alternative to onsite storage and diagnostics. This paper conducts a techno-economic assessment of a provisional cloud deployment architecture for a NPP predictive monitoring (PdM) system. The cloud-based monitoring system would enable maintenance and diagnostics (M&D) analysts and other authorized plant users to remotely monitor equipment functionality so as to enable PdM practices and early detection of faults. The Microsoft Azure cloud platform is included in the proposed cloud architecture to provide data processing and storage, sensor device networking, and database management; however, this analysis could be extended to other cloud computing service providers as well. For the techno-economic assessment, technical feasibility is measured in terms of network performance metrics such as response time, latency, and throughput, whereas economic feasibility is measured in terms of operational costs and capital expenditures. Finally, this report covers certain regulatory and security aspects that may concern licensees looking to implement cloud computing. The report focuses on the integration of sensor database storage, the application of cloud resources to PdM, and the identification of technological and economic hurdles associated with moving to a cloud-computing-based architecture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Update on Microreactor Automated Control System (MACS)

Automation of control systems is expected to be important in the economic and safe operation of microreactors. There is a need to develop and demonstrate automated control for microreactors, along with the development of testbeds for this purpose. This report provides updates on the status of a microreactor automated control system (MACS) testbed developed to test control system automation. While a future goal is to demonstrate this system using a prototypic microreactor such as MARVEL, the present focus is on developing and testing within a non-nuclear testbed. The testbed, developed in collaboration with Idaho National Laboratory, includes hardware-in-the-loop simulation and uses a Modelica-based model of a prototypic microreactor for use in testing control automation. Research to date at Oak Ridge National Laboratory has focused on the development of prototypic software for automating plant-level control under selected scenarios. Empirical testing on the integrated MACS testbed was performed to quantify key characteristics of the integrated testbed and to demonstrate the use of the software for automating the calculation and use of actuation setpoints for selected load-following scenarios. Ongoing research is focused on integrating additional control algorithms that utilize data from newly included sensors within the MACS hardware testbed, as well as demonstrating and assessing the performance of the different automated control algorithms on multiple additional operational scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Microreactor Automated Control System - Digital Twin Models and Advanced Control Systems Updates

Automation of control systems is expected to be important in the economic and safe operation of microreactors. Therefore, there is a need to develop and demonstrate automated control for microreactors, along with the development of testbeds for this purpose. This report provides updates on the status of a nonnuclear microreactor automated control system (MACS)—a real-time, hardware-in-the-loop testbed for non-nuclear testing of microreactor control system automation. A real-time hardware-in-the-loop testbed incorporates the realistic dynamics of physical systems into control system development and testing. The collaborative effort between Oak Ridge National Laboratory (ORNL) and Idaho National Laboratory (INL) resulted in the development of a prototypic microreactor plant-level digital twin that includes the reactor and a balance of plant system. Advanced control strategies were incorporated to demonstrate testing of control automation solutions. The gRPC communication protocol, which was implemented in the hardware-in-the-loop testbed by INL, was coupled to a digital twin model developed using the TRANsient Simulation Framework of Reconfigurable Models (TRANSFORM) library in Modelica. This digital twin simulation was tested with the ViBRANT hardware for realistic feedback and visual representation of control action in real time. A modular Python client structure was developed to manage functional mock-up unit-based simulation and real-time gRPC communication. Hardware-in-the-loop testing indicated that the modeled reactor—a natural-convection, molten-salt coolant loop configuration—responds well to control of drum positioning for modulation of reactor core power, as well as system-level control and downstream demand changes. Ongoing research is focused on integrating additional control algorithms that utilize data from newly included sensors within the MACS hardware testbed, as well as demonstrating and assessing the performance of the different automated control algorithms on multiple additional operational scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Grid Topology Discovery Algorithm Evaluation of Suitability for Utility Deployment (CRADA 606 Final Report)

This work presents the results of a field-informed demonstration aimed at evaluating the practical suitability of a topology discovery algorithm for utility environments. We demonstrated an algorithm that uses a graph-theory-informed state estimation approach for model selection. In collaboration with Survalent and Peninsula Light Co., the algorithm was applied to real feeder models and field measurements from supervisory control and data acquisition (SCADA) and advanced metering infrastructure (AMI) systems to identify the operational topology of a power distribution system. The demonstration assessed the algorithm’s performance under realistic data conditions, including sparse and noisy measurements, and examined its ability to identify the most likely network configurations. The results confirmed that the approach can effectively narrow down feasible topologies, providing operators with improved situational awareness of network status. Key lessons learned emphasize the need for systematic data validation and strategic sensor placement to enhance observability. These insights inform future deployment strategies and guide refinements for broader adoption in utility operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Efficient human activity recognition with spatio-temporal spiking neural networks

In this study, we explore Human Activity Recognition (HAR), a task that aims to predict individuals' daily activities utilizing time series data obtained from wearable sensors for health-related applications. Although recent research has predominantly employed end-to-end Artificial Neural Networks (ANNs) for feature extraction and classification in HAR, these approaches impose a substantial computational load on wearable devices and exhibit limitations in temporal feature extraction due to their activation functions. To address these challenges, we propose the application of Spiking Neural Networks (SNNs), an architecture inspired by the characteristics of biological neurons, to HAR tasks. SNNs accumulate input activation as presynaptic potential charges and generate a binary spike upon surpassing a predetermined threshold. This unique property facilitates spatio-temporal feature extraction and confers the advantage of low-power computation attributable to binary spikes. We conduct rigorous experiments on three distinct HAR datasets using SNNs, demonstrating that our approach attains competitive or superior performance relative to ANNs, while concurrently reducing energy consumption by up to 94%.

60 APPLIED LIFE SCIENCES↗

On optimizing the sensor spacing for pressure measurements on wind turbine airfoils

This research article presents a robust approach to optimizing the layout of pressure sensors around an airfoil. A genetic algorithm and a sequential quadratic programming algorithm are employed to derive a sensor layout best suited to represent the expected pressure distribution and, thus, the lift force. The fact that both optimization routines converge to almost identical sensor layouts suggests that an optimum exists and is reached. By comparing against a cosine-spaced sensor layout, it is demonstrated that the underlying pressure distribution can be captured more accurately with the presented layout optimization approach. Conversely, a 39 %–55 % reduction in the number of sensors compared to cosine spacing is achievable without loss in lift prediction accuracy. Given these benefits, an optimized sensor layout improves the data quality, reduces unnecessary equipment and saves cost in experimental setups. While the optimization routine is demonstrated based on the generic example of the IEA 15 MW reference wind turbine, it is suitable for a wide range of applications requiring pressure measurements around airfoils.

17 WIND ENERGY↗