Search NASA⌕ Search

SEARCH · Search NASA

Results for “shape approximation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Simple expressions of the nuclear relaxation rate enhancement due to quadrupole nuclei in slowly tumbling molecules

For slowly tumbling entities or quasi-rigid lattices, we derive very simple analytical expressions of the quadrupole relaxation enhancement (QRE) of the longitudinal relaxation rate R{sub 1} of nuclear spins I due to their intramolecular magnetic dipolar coupling with quadrupole nuclei of arbitrary spins S ≥ 1. These expressions are obtained by using the adiabatic approximation for evaluating the time evolution operator of the quantum states of the quadrupole nuclei S. They are valid when the gyromagnetic ratio of the spin S is much smaller than that of the spin I. The theory predicts quadrupole resonant peaks in the dispersion curve of R{sub 1} vs magnetic field. The number, positions, relative intensities, Lorentzian shapes, and widths of these peaks are explained in terms of the following properties: the magnitude of the quadrupole Hamiltonian and the asymmetry parameter of the electric field gradient (EFG) acting on the spin S, the S-I inter-spin orientation with respect to the EFG principal axes, the rotational correlation time of the entity carrying the S–I pair, and/or the proper relaxation time of the spin S. The theory is first applied to protein amide protons undergoing dipolar coupling with fast-relaxing quadrupole {sup 14}N nuclei and mediating the QRE to the observed bulk water protons. The theoretical QRE agrees well with its experimental counterpart for various systems such as bovine pancreatic trypsin inhibitor and cartilages. The anomalous behaviour of the relaxation rate of protons in synthetic aluminium silicate imogolite nano-tubes due to the QRE of {sup 27}Al (S = 5/2) nuclei is also explained.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-stage gradient-based stellarator coil design: Optimization for near-axis quasi-symmetry

Here we present a new coil design paradigm for magnetic confinement in stellarators. Our approach directly optimizes coil shapes and coil currents to produce a vacuum quasi-symmetric magnetic field with a target rotational transform on the magnetic axis. This approach differs from the traditional two-stage approach in which first a magnetic configuration with desirable physics properties is found, and then coils to approximately realize this magnetic configuration are designed. The proposed single-stage approach allows us to find a compromise between confinement and engineering requirements, i.e., find easy-to-build coils with good confinement properties. Using forward and adjoint sensitivities, we derive derivatives of the physical quantities in the objective, which is constrained by a nonlinear periodic differential equation. In two numerical examples, we compare different gradient-based descent algorithms and find that incorporating approximate second-order derivative information through a quasi-Newton method is crucial for convergence. We also explore the optimization landscape in the neighborhood of a minimizer and find many directions in which the objective is mostly flat, indicating ample freedom to find simple and thus easy-to-build coils.

97 MATHEMATICS AND COMPUTING↗

The GCT camera for the Cherenkov Telescope Array

The Gamma Cherenkov Telescope (GCT) is one of the designs presented for the Small Sized Telescope (SST) section of the Cherenkov Telescope Array (CTA). The GCT uses dual-mirror optics, resulting in a compact telescope with good image quality and a large field of view with a smaller, more economical, camera than is achievable with conventional single mirror solutions. The photon counting GCT camera is designed to record the flashes of atmospheric Cherenkov light from gamma and cosmic ray initiated cascades, which last only a few tens of nanoseconds. The GCT optics require that the camera detectors follow a convex surface with a radius of curvature of 1 m and a diameter of ~35 cm, which is approximated by tiling the focal plane with 32 modules. The initial camera prototype is equipped with multi-anode photomultipliers, each comprising an 8×8 array of 6×6 mm 2 pixels to provide the required angular scale, adding up to 2048 pixels in total. Detector signals are shaped, amplified and digitised by electronics based on custom ASICs that provide digitisation at 1 GSample/s. The camera is self-triggering, retaining images where the focal plane light distribution matches predefined spatial and temporal criteria. The electronics are housed in the liquid-cooled, sealed camera enclosure. LED flashers at the corners of the focal plane provide a calibration source via reflection from the secondary mirror. The first GCT camera prototype underwent preliminary laboratory tests last year. In November 2015, the camera was installed on a prototype GCT telescope (SST-GATE) in Paris and was further used to successfully record the first Cherenkov light of any CTA prototype, and the first Cherenkov light seen with such a dual-mirror optical system. A second full-camera prototype based on Silicon Photomultipliers is under construction. Up to 35 GCTs are envisaged for CTA.

47 OTHER INSTRUMENTATION↗

Ion composition produced by high power impulse magnetron sputtering discharges near the substrate

Plasma composition near the substrate was investigated in a high power impulse magnetron sputtering (HIPIMS) discharge using Langmuir probe analysis, mass spectroscopy, and atomic absorption spectroscopy. The HIPIMS discharge was operated in nonreactive Ar atmosphere at a pressure of 2.66 Pa and the magnetron cathode was furnished with Ti target. Plasma density, metal ion-to-neutral ratio, and gas ion-to-metal ion ratio were studied as a function of discharge current. At peak discharge current densities of {approx}1 A cm{sup -2}, the results show that a dense plasma (n{sub e}{approx}10{sup 18} m{sup -3}) expanded from the target toward the substrate and lasted more than 330 {mu}s after the supplied power was turned off. The shape of the time-averaged ion energy distribution function of sputtered material exhibited a transition from Thompson to Maxwellian distribution, indicating efficient energy transfer in the discharge. The metal content in the plasma monotonically increased with discharge current and the metal ion-to-neutral ratio reached approximately 1:1 in the postdischarge plasma at peak current density of 5 A cm{sup -2}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Internal structure of 0.9 GHz microplasma

Argon microplasmas generated at 0.9 GHz by a split-ring resonator form a single filament-shaped nonequilibrium glow discharge. The internal structure of these microplasmas is probed using laser diode absorption and imaging emission spectrometry. These two-dimensional diagnostics are then Abel inverted to reveal that the core of the filament has a strongly depleted central metastable argon population. The microdischarges are approximately 0.2 mm in width at 1 atm and expand with increasing input power between 0.05-1.5 W. The relative electron density and the Ar(4p) density are estimated from the emission detected by a CCD camera through various bandpass filters. Absolute Ar(4s) densities, on the other hand, are determined by Ar 801.4 nm absorption. The Ar(4s) profile transitions from center-peaked at low power (0.05 W) to center-depleted above 0.25 W, saturating at 10{sup 19} m{sup -3}. The electron density profile within the microplasma, however, remains center-peaked regardless of the power. The spatially-resolved gas temperature was estimated from the broadening of the Ar 801.4 nm absorption profile. The error in this gas temperature measurement due to the depletion of the metastable atoms is corrected using numerical heat transfer models and shown to be 1650 K if the plasma power is 1.2 W. Differences between the peak and average temperatures based on the nitrogen rotational spectrum are also explained using nitrogen emission imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The general theory of secondary weak gravitational lensing

Weak gravitational lensing is normally assumed to have only two principle effects: a magnification of a source and a distortion of the sources shape in the form of a shear. However, further distortions are actually present owing to changes in the gravitational field across the scale of the ray bundle of light propagating to us, resulting in the familiar arcs in lensed images. This is normally called the flexion, and is approximated by Taylor expanding the shear and magnification across the image plane. However, the physical origin of this effect arises from higher-order corrections in the geodesic deviation equation governing the gravitational force between neighbouring geodesics— so involves derivatives of the Riemann tensor. We show that integrating the second-order geodesic deviation equation results in a 'Hessian map' for gravitational lensing, which is a higher-order addition to the Jacobi map. We derive the general form of the Hessian map in an arbitrary spacetime paying particular attention to the separate effects of local Ricci versus non-local Weyl curvature. We then specialise to the case of a perturbed FLRW model, and give the general form of the Hessian for the first time. This has a host of new contributions which could in principle be used as tests for modified gravity.

79 ASTRONOMY AND ASTROPHYSICS↗

Determining Reactor Fuel Type from Continuous Antineutrino Monitoring

In this work, we investigate the ability of an antineutrino detector to determine the fuel type of a reactor. A hypothetical 5-ton antineutrino detector is placed 25 m from the core and measures the spectral shape and rate of antineutrinos emitted by fission fragments in the core for a number of 90-d periods. Our results indicate that four major fuel types can be differentiated from the variation of fission fractions over the irradiation time with a true positive probability of detection at approximately 95%. In addition, we demonstrate that antineutrinos can identify the burnup at which weapons-grade mixed-oxide (MOX) fuel would be reduced to reactor-grade MOX, on average, providing assurance that plutonium-disposition goals are met. We also investigate removal scenarios where plutonium is purposefully diverted from a mixture of MOX and low-enriched uranium fuel. Lastly, we discuss how our analysis is impacted by a spectral distortion around 6 MeV observed in the antineutrino spectrum measured from commercial power reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Casimir energies of cylinders: Universal function

New exact results are given for the interior Casimir energies of infinitely long waveguides of triangular cross section (equilateral, hemiequilateral, and isosceles right triangles). Results for cylinders of rectangular cross section are rederived. In particular, results are obtained for interior modes belonging to Dirichlet and Neumann boundary conditions (TM and TE modes). These results are expressed in rapidly convergent series using the Chowla-Selberg formula, and in fact may be given in closed form, except for general rectangles. The energies are finite because only the first three heat-kernel coefficients can be nonzero for the case of polygonal boundaries. What appears to be a universal behavior of the Casimir energy as a function of the shape of the regular or quasiregular cross-sectional figure is presented. Furthermore, numerical calculations for arbitrary right triangular cross sections suggest that the universal behavior may be extended to waveguides of general polygonal cross sections. The new exact and numerical results are compared with the proximity force approximation (PFA).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The development of the time dependence of the nuclear EMP electric field

The nuclear electromagnetic pulse (EMP) electric field calculated with the legacy code CHAP is compared with the field given by an integral solution of Maxwell's equations, also known as the Jefimenko equation, to aid our current understanding on the factors that affect the time dependence of the EMP. For a fair comparison the CHAP current density is used as a source in the Jefimenko equation. At first, the comparison is simplified by neglecting the conduction current and replacing the standard atmosphere with a constant density air slab. The simplicity of the resultant current density aids in determining the factors that affect the rise, peak and tail of the EMP electric field versus time. The three dimensional nature of the radiating source, i.e. sources off the line-of-sight, and the time dependence of the derivative of the current density with respect to time are found to play significant roles in shaping the EMP electric field time dependence. These results are found to hold even when the conduction current and the standard atmosphere are properly accounted for. Comparison of the CHAP electric field with the Jefimenko electric field offers a direct validation of the high-frequency/outgoing wave approximation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron detection in a high-gamma field using solution-grown stilbene

We present that a solution-based technique for growing large-volume stilbene scintillators was developed in 2013; crystals up to diameters of 10 cm, or larger, have been grown while preserving excellent pulse shape discrimination (PSD) properties. The goal of this study is to evaluate the PSD capabilities of 5.08 by 5.08-cm stilbene crystals grown by Lawrence Livermore National Laboratory and Inrad Optics when exposed to a 1000 to 1 gamma ray-neutron ratio and operating at a 100-kHz count rate. Results were compared to an equivalent EJ-309 liquid scintillation detector. 252 Cf neutron pulses were recorded in two experiments where 60 Co and 137 Cs sources created the high-gamma field. The high count rate created numerous double pulses that were cleaned using fractional and template approaches designed to remove double pulses while preserving neutron counts. PSD was performed at a threshold of 42 keVee (440-keV proton) for stilbene and 60 keVee (610-keV proton) for EJ-309 liquid. The lower threshold in stilbene resulted in a neutron intrinsic efficiency of approximately 14.5%, 10% higher than EJ-309 liquid, for bare 252 Cf and 13% for 252 Cf in the high-gamma field. Despite the lower threshold, the gamma misclassification rate in stilbene was approximately 3×10 $-$6 , nearly a factor-of-five lower than what we found with the EJ-309 liquid.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interaction of Harmonic Longitudinal Shear Waves with V-Shaped Inclusions

We solve the problem of determination of the stressed state in the vicinity of a tunnel rigid inclusion whose cross section consists of two segments originating out from the same point. The inclusion is placed in an infinite elastic medium with propagating plane harmonic longitudinal shear waves. The problem is reduced to the solution of a system of two singular integral equations with fixed singularities. For the approximate solution of this system, we apply a numerical method that takes into account the true asymptotics of the unknown functions and is based on the use of special quadrature formulas for the evaluation of singular integrals.

97 MATHEMATICS AND COMPUTING↗

Phase-space analysis and experimental results for secondary focusing at X-ray beamlines

Micro-focusing optical devices at synchrotron beamlines usually have a limited acceptance, but more flux can be intercepted if such optics are used to focus secondary sources created by the primary optics. Flux throughput can be maximized by placing the secondary focusing optics close to or exactly at the secondary source position. However, standard methods of beamline optics analysis, such as the lens equation or matching the mirror surface to an ellipse, work poorly when the source-to-optics distance is very short. In this paper the general characteristics of the focusing of beams with Gaussian profiles by a 'thin lens' are analysed under the paraxial approximation in phase space, concluding that the focusing of a beam with a short source-to-optics distance is distinct from imaging the source; slope errors are successfully included in all the formulas so that they can be used to calculate beamline focusing with good accuracy. A method is also introduced to use the thin-lens result to analyse the micro-focusing produced by an elliptically bent trapezoid-shaped Kirkpatrick-Baez mirror. The results of this analysis are in good agreement with ray-tracing simulations and are confirmed by the experimental results of the secondary focusing at the 18-ID Bio-CAT beamline (at the APS). The result of secondary focusing carried out at 18-ID using a single-bounce capillary can also be explained using this phase-space analysis. A discussion of the secondary focusing results is presented at the end of this paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Angular dependence of the response of the nanoDot OSLD system for measurements at depth in clinical megavoltage beams

Purpose: The purpose of this investigation was to assess the angular dependence of a commercial optically stimulated luminescence dosimeter (OSLD) dosimetry system in MV x-ray beams at depths beyondd{sub max} and to find ways to mitigate this dependence for measurements in phantoms. Methods: Two special holders were designed which allow a dosimeter to be rotated around the center of its sensitive volume. The dosimeter's sensitive volume is a disk, 5 mm in diameter and 0.2 mm thick. The first holder rotates the disk in the traditional way. It positions the disk perpendicular to the beam (gantry pointing to the floor) in the initial position (0°). When the holder is rotated the angle of the disk towards the beam increases until the disk is parallel with the beam (“edge on,” 90°). This is referred to as Setup 1. The second holder offers a new, alternative measurement position. It positions the disk parallel to the beam for all angles while rotating around its center (Setup 2). Measurements with five to ten dosimeters per point were carried out for 6 MV at 3 and 10 cm depth. Monte Carlo simulations using GEANT4 were performed to simulate the response of the active detector material for several angles. Detector and housing were simulated in detail based on microCT data and communications with the manufacturer. Various material compositions and an all-water geometry were considered. Results: For the traditional Setup 1 the response of the OSLD dropped on average by 1.4% ± 0.7% (measurement) and 2.1% ± 0.3% (Monte Carlo simulation) for the 90° orientation compared to 0°. Monte Carlo simulations also showed a strong dependence of the effect on the composition of the sensitive layer. Assuming the layer to completely consist of the active material (Al{sub 2}O{sub 3}) results in a 7% drop in response for 90° compared to 0°. Assuming the layer to be completely water, results in a flat response within the simulation uncertainty of about 1%. For the new Setup 2, measurements and Monte Carlo simulations found the angular dependence of the dosimeter to be below 1% and within the measurement uncertainty. Conclusions: The dosimeter system exhibits a small angular dependence of approximately 2% which needs to be considered for measurements involving other than normal incident beams angles. This applies in particular to clinicalin vivo measurements where the orientation of the dosimeter is dictated by clinical circumstances and cannot be optimized as otherwise suggested here. When measuring in a phantom, the proposed new setup should be considered. It changes the orientation of the dosimeter so that a coplanar beam arrangement always hits the disk shaped detector material from the thin side and thereby reduces the angular dependence of the response to within the measurement uncertainty of about 1%. This improvement makes the dosimeter more attractive for clinical measurements with multiple coplanar beams in phantoms, as the overall measurement uncertainty is reduced. Similarly, phantom based postal audits can transition from the traditional TLD to the more accurate and convenient OSLD.

61 RADIATION PROTECTION AND DOSIMETRY↗

Second-order spectral line shift comparisons

The second-order spectral line width formulae from the projection operator and kinetic theory methods were recently compared. It was shown that a systematic expansion of the projection operator width expression including initial correlations formally agrees with the second-order kinetic theory result. It is now shown that the second-order dynamic shifts are also formally the same. The static shifts, however, differ due to an ad hoc treatment of electron-electron correlations in the projection operator method. The approximation is necessary in order to screen the radiator-electron interactions. The differences, however, are expected to be small. Finally, the results suggest using the rigorous and more compact second-order width and shift expressions from the kinetic theory method as the starting point for spectral line shape calculations. At line center, however, the projection operator second-order expression for the width and shift simplifies and reduces to the kinetic theory result.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A 3-D multiband closure for radiation and neutron transfer moment models

We derive a 3D multi-band moment model and its associated closure for radiation and neutron transfer. The new closure is analytical and nonlinear but very simple. Its derivation is based on the maximum entropy closure and assumes a Wien shape for the intensity when used in the Eddington tensor. In the multi-band approach, the opacity is re-arranged (binned) according to the opacity value. The multi-band model propagates identically all photons/neutrons having the same opacity. This has been found to be a good approximation on average since the transport is mostly determined by the opacities and less by the frequencies. This same concept is used to derive the closure. We prove on two complex test atmospheres (the solar atmosphere and an artificial atmosphere) that the closure we have derived has good accuracy. All approximations made in deriving the model have been carefully numerically checked and quantified.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

VECTOR MAGNETIC FIELDS AND CURRENT HELICITIES IN CORONAL HOLES AND QUIET REGIONS

In the solar photosphere, many properties of coronal holes (CHs) are not known, especially vector magnetic fields. Using observations from Hinode, we investigate vector magnetic fields, current densities, and current helicities in two CHs, and compare them with two normal quiet regions (QRs) for the first time. We find that the areas where large current helicities are located are mainly co-spatial with strong vertical and horizontal field elements both in shape and in location. In the CHs, horizontal magnetic fields, inclination angles, current densities, and current helicities are larger than those in the QRs. The mean vertical current density and current helicity in the CHs and QRs, averaged over all the observed areas including the CHs and QRs, are approximately 0.008 A m{sup -2} and 0.005 G{sup 2} m{sup -1}, respectively. The mean current density in magnetic flux concentrations where the vertical fields are stronger than 100 G is as large as 0.012 {+-} 0.001 A m{sup -2}, consistent with that in the flare productive active regions. Our results imply that the magnetic fields, especially the strong fields, both in the CHs and in the QRs are nonpotential.

79 ASTRONOMY AND ASTROPHYSICS↗

DARK MATTER IN THE CLASSICAL DWARF SPHEROIDAL GALAXIES: A ROBUST CONSTRAINT ON THE ASTROPHYSICAL FACTOR FOR {gamma}-RAY FLUX CALCULATIONS

We present a new analysis of the relative detectability of dark matter annihilation in the Milky Way's eight 'classical' dwarf spheroidal (dSph) satellite galaxies. Ours is similar to previous analyses in that we use Markov-Chain Monte Carlo techniques to fit dark matter halo parameters to empirical velocity dispersion profiles via the spherical Jeans equation, but more general in the sense that we do not adopt priors derived from cosmological simulations. We show that even without strong constraints on the shapes of dSph dark matter density profiles (we require only that the inner profile satisfies -liM{sub r {yields} 0} dln {rho}/dln r {<=} 1), we obtain a robust and accurate constraint on the astrophysical component of a prospective dark matter annihilation signal, provided that the integration angle is approximately twice the projected half-light radius of the dSph divided by distance to the observer, {alpha}{sub int} {approx} 2r{sub h} /d. Using this integration angle, which represents a compromise between maximizing prospective flux and minimizing uncertainty in the dSph's dark matter distribution, we calculate the relative detectability of the classical dSphs by ground- and space-based {gamma}-ray observatories.

79 ASTRONOMY AND ASTROPHYSICS↗

VIBRATIONALLY EXCITED HCN AROUND AFGL 2591: A PROBE OF PROTOSTELLAR STRUCTURE

Vibrationally excited molecules with submillimeter rotational transitions are potentially excellent probes of physical conditions near protostars. This study uses observations of the v = 1 and v = 2 ro-vibrational modes of HCN (4-3) to probe this environment. The presence or absence and relative strengths of these ro-vibrational lines probe the gas excitation mechanism and physical conditions in warm, dense material associated with protostellar disks. We present pilot observations from the Heinrich Hertz Submillimeter Telescope and follow-up observations from the Submillimeter Array. All vibrationally excited HCN (4-3) v = 0, v = 1, and v = 2 lines were observed. The existence of the three v = 2 lines at approximately equal intensity imply collisional excitation with a density of greater than (10{sup 10} cm{sup -3}) and a temperature of >1000 K for the emitting gas. This warm, high-density material should directly trace structures formed in the protostellar envelope and disk environment. Further, the line shapes of the v = 2 emission may suggest a Keplerian disk. This Letter demonstrates the utility of this technique which is of particular interest due to the recent inauguration of the Atacama Large Millimeter Array.

79 ASTRONOMY AND ASTROPHYSICS↗