Search NASA⌕ Search

SEARCH · Search NASA

Results for “solution phase”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

High radiation tolerance of an ultrastrong nanostructured NiCoCr alloy with stable dispersed nanooxides and fine grain structure

The present paper reports the irradiation behavior of nanostructured NiCoCr medium entropy alloy enhanced by Y-Hf-O nanooxides and fine grains produced by powder metallurgy. Ion beam irradiation to a peak dose of 130 dpa at 580°C produced neither detectable void swelling nor irradiation-induced hardening, in contrast to significant void swelling and property degradation of single phase NiCoCr concentrated solid-solution alloy under the similar irradiation condition. The dispersed nanooxides and high density of grain boundaries act as defect sinks that effectively annihilate irradiation-induced interstitials and vacancies. Furthermore, high-density nanooxides maintain their crystalline structures and stabilize the grain boundaries during irradiation.

36 MATERIALS SCIENCE↗

Hydrothermal discharge from the El Tatio basin, Atacama, Chile

El Tatio in northern Chile is one of the best-studied geothermal fields in South America. However, there remain open questions about the mass and energy budgets, water recharge rates and residence time in the subsurface, origin of dissolved solutes, and processes affecting the phase and chemical composition of groundwater and surface water. Here we measured and sampled surface manifestations of the geothermal system (geysers, perpetual spouters, mud pools/volcanoes, and non-eruptive hot springs) and meteoric water. From the isotopic composition we infer that the thermal water has a meteoric origin that is different from the composition of local meteoric water. The absence of detectable tritium in thermal waters indicates that most of the recharge occurred pre-1950. Boiling and steam separation from the deep reservoir appear to be the main subsurface processes affecting the thermal fluids. A large amount of heat is lost to the atmosphere by evaporation from surface water and by steam emitted from erupting geysers. Finally, using the chloride inventory method, we estimate thermal water discharge to be 218 to 234 L/s, and the advective heat flow to be 120 to 170 MW.

15 GEOTHERMAL ENERGY↗

Sources of deactivation during glycerol conversion on Ni/γ-Al 2 O 3

Hydrogenolysis of glycerol was studied using a diluted aqueous solution of glycerol in gas phase and atmospheric pressure on Ni/γ-Al2O3 catalyst. The catalytic transformation of glycerol generates products derived from dehydration, dehydrogenation, hydrogenolysis and condensation reactions. Deep hydrogenolysis route to produce CH4 prevails in the first few hours of reaction. As the reaction time progress, dehydration-dehydrogenation products start to appear. Here, a description of the deactivation sources and its effects on the catalytic performance of Ni catalyst was proposed. The catalyst was characterized before and after the catalytic reaction by high-resolution transmission electron microscopy (HRTEM) and by employing Fourier transformed infrared spectroscopy (FTIR) of adsorbed CO. A source of deactivation was due to carbonaceous deposition. FTIR at low CO dosing pressure reveal bands assignments species essentially due to linear and bridge carbonyls, whereas high pressure CO dosing produces a complex spectra due to polycarbonyls. X-ray absorption near edge structure (XANES) analysis was employed to reveal the initial degree of reduction of the fresh catalyst. The oxidation of metallic Ni in the course of reaction may also be considered as a source of deactivation. Ni oxide species promote dehydration routes. Alumina support facilitates nickel species to be more active toward interacting with glycerol. Dehydration, which takes place on the acid sites, is the mainly route related to the generation of carbon deposition and to the observed catalyst deactivation. Another source of deactivation was due to carbiding of Ni to form Ni3C. The regeneration of used Ni catalyst was achieved by oxidation-reduction steps at 723 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scalable fabrication and coating methods for perovskite solar cells and solar modules

Since the report in 2012 of a solid-state perovskite solar cell (PSC) with a power-conversion efficiency (PCE) of 9.7% and a stability of 500 h, intensive efforts have been made to increase the certified PCE, reaching 25.2% in 2019. The PCE of PSCs now exceeds that of conventional thin-film solar-cell technologies, and the rate at which this increase has been achieved is unprecedented in the history of photovoltaics. Moreover, the development of moisture-stable and heat-stable materials has increased the stability of PSCs. Small-area devices (<1 cm2) are typically fabricated using a spin-coating method; however, this approach may not be suitable for the preparation of the large-area (>100 cm2) substrates required for commercialization. Thus, materials and methods need to be developed for coating large-area PSCs. In this Review, we discuss solution-based and vapour-phase coating methods for the fabrication of large-area perovskite films, examine the progress in performance and the parameters affecting the properties of large-area coatings, and provide an overview of the methodologies for achieving high-efficiency perovskite solar modules.

14 SOLAR ENERGY↗

Soft-donor dipicolinamide derivatives for selective actinide( iii )/lanthanide( iii ) separation: the role of S- vs. O-donor sites

Selectivity for An(III) vs. Ln(III) binding and extraction with dipicolinamide analogs containing the C=O vs. C=S groups was investigated in solution and the gas-phase, and by DFT calculations. The results reflect higher selectivity for complex formation and extraction for Am(III) vs. Eu(III) for the softer dithioamide vs. the diamide ligand, while in CH 3 CN the diamide binds more strongly than the thioamide to several Ln(III), forming 1:1 complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A classical view on nonclassical nucleation

Significance Nucleation is the process by which constituent building blocks first assemble to form a new substance. In the case of mineral formation from initially free ions in solution, the emergence of intermediary phases often determines the thermodynamics and kinetics of formation for the most stable phase. Our work on CaCO 3 mineralization reevaluates a topic of intense discussion: Can nucleation be explained by theories established over a century ago, or should new physical concepts, as recently proposed, be adopted? Our data show that classical theories can indeed be used to describe complex mechanisms of crystallization. In addition, we provide information about the properties of intermediate phases, which will aid in the design of additives to control mineralization.

Smeets, Paul J. M.↗

Quantitative analysis of time-resolved microwave conductivity data

Flash-photolysis time-resolved microwave conductivity (fp-TRMC) is a versatile, highly sensitive technique for studying the complex photoconductivity of solution, solid, and gas-phase samples. The purpose of this paper is to provide a standard reference work for experimentalists interested in using microwave conductivity methods to study functional electronic materials, describing how to conduct and calibrate these experiments in order to obtain quantitative results. The main focus of the paper is on calculating the calibration factor, K, which is used to connect the measured change in microwave power absorption to the conductance of the sample. We describe the standard analytical formulae that have been used in the past, and compare them to numerical simulations. This comparison shows that the most widely used analytical analysis of fp-TRMC data systematically under-estimates the transient conductivity by ~60%. We suggest a more accurate semi-empirical way of calibrating these experiments. However, we emphasize that the full numerical calculation is necessary to quantify both transient and steady-state conductance for arbitrary sample properties and geometry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dirac fast scramblers

In this work, we introduce a family of Gross-Neveu-Yukawa models with a large number of fermion and boson flavors as higher dimensional generalizations of the Sachdev-Ye-Kitaev model. The models may be derived from local lattice couplings and give rise to Lorentz invariant critical solutions in 1+1 and 2+1 dimensions. These solutions imply anomalous dimensions of both bosons and fermions tuned by the number ratio of boson to fermion flavors. In 1+1 dimension the solution represents a stable critical phase, while in 2+1 dimension it governs a quantum phase transition. We compute the out of time order correlators in the 1+1 dimensional model, showing that it exhibits growth with the maximal Lyapunov exponent λ L =2πT in the low temperature limit.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Absolute calibration of optical streak cameras on picosecond time scales using supercontinuum generation

Here we report a new method using high stability, laser-driven supercontinuum generation in a liquid cell to calibrate the absolute photon response of fast optical streak cameras as a function of wavelength when operating at fastest sweep speeds. A stable, pulsed white light source based around the use of self-phase modulation in a salt solution was developed to provide the required brightness on picosecond timescales, enabling streak camera calibration in fully dynamic operation. The measured spectral brightness allowed for absolute photon response calibration over a broad spectral range (425-650nm). Calibrations performed with two Axis Photonique streak cameras using the Photonis P820PSU streak tube demonstrated responses which qualitatively follow the photocathode response. Peak sensitivities were 1 photon/count above background. The absolute dynamic sensitivity is less than the static by up to an order of magnitude. We attribute this to the dynamic response of the phosphor being lower.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods for the chemical synthesis of carbon nanotubes: an approach based on hemispherical polyarene templates

Abstract Hemispherical polyarenes represent attractive templates from which carbon nanotubes of the same diameter and rim structure (chirality) might be grown by repetitive annulation reactions. The resulting single-index ( n,m ) nanotubes would have one end open and the other end capped by the original template. Efforts in the author’s laboratory to synthesize (5,5) and (6,6) nanotube end-caps are described. Nitroethylene is shown to serve well as a “masked acetylene” for the conversion of polyarene bay regions into new unsubstituted benzene rings by a Diels-Alder cycloaddition/aromatization process. Benzyne reacts similarly, both in solution and in the gas phase. These annulation reactions are proposed as methods for elongating large-diameter templates that have bay regions on their rims into structurally uniform, single-walled carbon nanotubes. Unfortunately, the bay regions on the strongly curved rim of the small-diameter (5,5) nanotube end-cap 3 resist Diels-Alder cycloadditions with both nitroethylene and benzyne. Pentabenzocorannulene ( 14 ) is proposed as a promising candidate for surface-catalyzed cyclodehydrogenation to a surface-bound hemispherical polyarene that could serve as a template for synthesis of pure (5,5) carbon nanotubes.

Chemistry↗

Advanced high-spatial-resolution diffraction diagnostics

Diffraction series data have been acquired and analyzed via multivariate statistical analysis. For two different data series analyzed, the data analysis was able to reduce the raw diffraction data series into a much smaller easier-to-interpret solution consisting mainly of crystallographic phase and orientation information.

36 MATERIALS SCIENCE↗

High Energy Micron Scale Pixel Hybrid Detector

The objective of this technology development project has been to fabricate and characterize a new X-ray area image sensor innovation designed for high efficiency detection and imaging of hard X-rays (>20 KeV) with micron scale pixel resolution. A key technology component consists of a monolithic hybrid X-ray detector built by layering an amorphous Selenium X-ray photoconductor film directly deposited on a small pitch (7.8μm) CMOS active pixel readout array. A specific goal of this work is to provide a new detector tool to researchers working with synchrotron light sources, to extend the depth of exploration into nanoscale structures, and do so cost effectively. Early generation X-ray imaging detector tools fail to provide adequate resolving power and efficiency at high energies and our innovation provides a solution. A majority of proposed phase I tasks were completed. Those tasks included, in collaboration with KA Imaging, successful fabrication of specified a-Se layers on a 1Mpixel CMOS readout array to create the direct hybrid X-ray imaging array, packaging of the imaging array, assembly of electronics into a shielded detector box, loading user interface software for camera control and image capture, and performing initial (no X-ray) detector evaluation at Farrier Microengineering facilities. After initial tests, extensive testing using the X-ray beam line 1-BM source at Argonne National Laboratory Advanced Photon Source(ANL-APS) was performed. Imaging performance studies were conducted at multiple X-ray beam energies. Studies included X-ray response vs. X-ray energy, vs. applied detector field strength (HV), response linearity vs. integration time, MTF vs. beam energy, image lag measurements, and micron scale resolution pattern target imaging. This high energy micron scale X-ray detection technology is a first of a kind to be evaluated at the ANL-APS and is supported by Dr. Antonino Miceli, head of the detector physics group. Accomplishments include the first successful demonstration of a 1Mpix amorphous Selenium on CMOS readout direct hybrid X-ray imaging detector at a DOE sponsored National Laboratory. Modeled performance predictions were confirmed, proving micron scale resolution as well as an order of magnitude increase in conversion efficiency over conventional scintillator detector performance. A discovery of evidence of propagation-based phase contrast edge enhancement was unplanned and will be exploited in future experiments. This phase 1 technology demonstration verifies the efficacy of proposed high energy micron scale pixel X-ray hybrid a-Se imaging array products. The new detector products will cost effectively replace early generation detector technologies that currently fail to address increasing demand for tools to study nano structures and physical processes at high X-ray energies above 20keV. For example, current systems for transmission X-ray microscopy have low efficiency and available large pixel (~55µm) direct detectors do not offer sufficient resolution for Bragg fringe imaging at high energies. This detector innovation will solve these inadequacies. The new detector technology will compete in a $50M scientific X-ray detector market, growing at 6%, and will benefit Microtomography(µCT), X-ray diffractometry (XRD), Coherent Diffraction Imaging (CDI) applications. One application specified by Dr. Miceli at ANL is the 3D reconstruction of compact crystals at high energies requires small pixel high efficiency X-ray detectors. Farrier Microengineering, working with colleagues at KA Imaging and the University of Waterloo, successfully achieved the critical objectives of the Phase I proposal. We have proven the technical feasibility of this innovation by building and successfully testing a 1Mpixel a-Se/CMOS hybrid direct X-ray imaging array. Our commercialization roadmap of detector products will be implemented during a phase II project. We will demonstrate a migration of the technology to larger detector array sizes, improved temporal performance with detector layer engineering, and improved environmental and operational stability. Manufacturability and cost effectiveness are key objectives and product designs will leverage current state of the art CMOS wafer fabrication quality and volume manufacturing economics.

36 MATERIALS SCIENCE↗

Framework for Greenhouse Gas Emissions Reduction Planning: Building Portfolios

The goal of this framework for greenhouse gas (GHG) emissions reduction planning (ERP) is to provide guidance to organizations seeking to reduce GHG emissions for their building portfolios and vehicle fleets. The process described in this framework helps organizations develop an actionable plan that prioritizes emissions reduction measures, identifies solutions, and lays out a phased pathway to achieve deep emissions reductions. The plan aims to result in the achievement of Scope 1 and 2 GHG emissions reduction targets, in alignment with goals set within the U.S. Department of Energy’s (DOE’s) Better Climate Challenge, as well as longer term emissions reduction goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Framework for Greenhouse Gas Emissions Reduction Planning: Building Portfolios

The goal of this Framework for greenhouse gas (GHG) emissions reduction planning (ERP) is to provide guidance to organizations seeking to reduce GHG emissions for their building portfolios and vehicle fleets. The process described in this framework helps organizations develop an actionable plan that prioritizes emissions reduction measures, identifies solutions, and lays out a phased pathway to achieve deep emissions reductions The plan aims to result in the achievement of Scope 1 and 2 GHG emissions reduction targets, in alignment with goals set within the U.S. Department of Energy’s (DOE’s) Better Climate Challenge, as well as longer term emissions reduction goals.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tracking and Orbit-Determination Program of the Jet Propulsion Laboratory

The lunar-probe tracking program at the Jet Propulsion Laboratory has two prime objectives: (1) provide real-time predictions of the direction of the probe from various observation stations; (2) establish a reliable trajectory corresponding to the actual flight path of the probe. The tracking program, although developed for use with lunar probes, can be used for interplanetary probes if certain modifications are made. The program, as developed for the IBM 704 digital computer, has two distinct phases. First, the equations of motion and the variational equations are integrated to each observation time where the elements of the equation A (sub u) equals b [linearization of the maximum likelihood equations] are computed. The second phase is concerned with the solution of a specified subset of A (sub u) equals b. Flexibility and ease of operation have been major objectives in writing the 704 program. The number of data points and tracking stations that may be used is limited only by computing time and core storage. Input formats and operating instructions are presented for utilizing the various computational options available in the program.

Carr, Russell E.↗