Search NASA⌕ Search

SEARCH · Search NASA

Results for “source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Alteration trends and geochemical source region characteristics preserved in the fluviolacustrine sedimentary record of Gale crater, Mars

The Mars Science Laboratory’s Chemistry and Camera (ChemCam) instrument suite on-board the Curiosity rover has analysed ~1200 sedimentary targets during the mission up to sol 1482. These targets have included sedimentary rock, diagenetic features (e.g., fracture-associated alteration halos, mineral veins, nodules, and erosion resistant raised ridges), active aeolian fines, soils and float. We have isolated ChemCam geochemical trends relating to diagenetic features and alteration products from those of the sedimentary rock in order to identify the compositional characteristics of Gale crater’s sediment source regions. The effects of grain size variation on sedimentary unit geochemistry have been taken into account by grouping and analysing geological units according to grain size. With obvious diagenetic features removed from the database, and predominately isochemical aqueous alteration inferred for the Mt Sharp Group samples, we propose that source region composition is a stronger source of geochemical change between the Bradbury and Mt Sharp Groups than open-system alteration. Additionally, a lack of correlation between the Chemical Index of Alteration (CIA) values and SiO 2 , MgO or FeO T indicates that the slight increase in chemical weathering of the Mt Sharp Group sediments was insufficient to overprint sediment source compositional signatures. This has led to the identification of five unique igneous endmember compositions which we hypothesise to have contributed to Gale crater’s stratigraphic record. These endmembers are: (1) a subalkaline basalt, compositionally similar to the tholeiitic Adirondack Class basalts of Gusev crater, and dominant within the finer grained units up to the base of Mt Sharp; (2) a trachybasalt, mostly identified within conglomerate units from the Darwin waypoint to the base of Mt Sharp; (3) a potassium-rich volcanic source, determined from strong potassium enrichment and a high abundance of sanidine that is most dominant in the fluvial sandstones and conglomerates of the Kimberley formation; (4) a highly evolved, silica-rich igneous source that correlates with the presence of tridymite, and is recorded in the lacustrine mudstone of Mt Sharp’s Marias Pass locality; and, (5) a fractionated, relatively SiO 2 -rich subalkaline basalt, seen to have influenced the composition of mudstone deposited in the lower part of the Mt Sharp Group. Endmembers (1), (2), (3), and (4) have previously been identified at specific waypoints along the rover’s traverse, but we show that their influence extends throughout Gale’s stratigraphic record. The occurrence of detected endmembers is also strongly correlated with stratigraphic position, which suggests changing sediment source regions with time. We conclude that Gale sediment provenances were much more varied than suggested by the largely homogenous, globally-distributed Martian basalt inferred from orbit, showing that complex magmatic assemblages exist within the ancient highland crust surrounding Gale.

58 GEOSCIENCES↗

Evaluation of Scatter Contribution and Distance Error by Iterative Methods for Strength Determination of HDR {sup 192}Ir Brachytherapy Source

High-dose rate (HDR) {sup 192}Ir brachytherapy sources are commonly used for management of malignancies by brachytherapy applications. Measurement of source strength at the hospital is an important dosimetry requirement. The use of 0.6-cm{sup 3} cylindrical ionization chamber is one of the methods of measuring the source strength at the hospitals because this chamber is readily available for beam calibration and dosimetry. While using the cylindrical chamber for this purpose, it is also required to determine the positioning error of the ionization chamber, with respect to the source, commonly called a distance error (c). The contribution of scatter radiation (M{sub s}) from floor, walls, ceiling, and other materials available in the treatment room also need to be determined accurately so that appropriate correction can be applied while calculating the source strength from the meter reading. Iterative methods of Newton-Raphson and least-squares were used in this work to determine scatter contribution in the experimentally observed meter reading (pC/s) of a cylindrical ionization chamber. Monte Carlo simulation was also used to cross verify the results of the least-squares method. The experimentally observed, least-squares calculated and Monte Carlo estimated values of meter readings from HDR {sup 192}Ir brachytherapy source were in good agreement. Considering procedural simplicity, the method of least-squares is recommended for use at the hospitals to estimate values of f (constant of proportionality), c, and M{sub s} required to determine the strength of HDR {sup 192}Ir brachytherapy sources.

07 ISOTOPE AND RADIATION SOURCES↗

Picosecond laser generated plasma as a source of singly charged ions for external injection into an EBIS

The focus of this paper is on practical aspects of ion generation by picosecond lasers as a source of low charge state ions for external injection of ions into an electron beam ion source (EBIS). For a ps-laser, compared to a ns-laser currently used at Relativistic Heavy Ion Collier Electron Beam Ion Source (RHIC EBIS), the influence of heat conductivity in the solid target is almost negligible, which results in a lower target consumption rate and less vacuum pressure rise. By using a laser with high repetition rate, it is possible to produce quasi continuous 1+ ion beams for periods of tens of milliseconds, making it possible to take advantage of the ability of the EBIS to accumulate ions in the “slow” injection capture mode. Producing such an ion pulse train is now feasible since ps-lasers with pulse energy up to 10 mJ and rep-rate up to 10 kHz have recently become commercially available. The advantages of this lower current accumulation scheme include: (1) easier beam transport due to lower space charge of lower beam currents required compared to the present single pulse fast injection scheme, (2) better EBIS pulse to pulse ion output stability since pulse to pulse ion variations of the laser source are averaged over a long train of laser pulses, and (3) the possible addition of an isotope separator in which rare beams could be produced and selected at run time from less expensive (unenriched) targets. We studied the properties of plasmas generated by a ps-laser with 1.27 mJ energy within an 8 ps pulse and a repetition rate up to 400 Hz at Argonne National Laboratory to investigate feasibility and specify parameters for a laser ion source for RHIC EBIS using a “slow” injection mode. Al, Ti, Cu, Nb, and Ta targets were tested with various target translation speeds. Here, we demonstrated that a both “slow” and “fast” injection modes are accessible with a single ion source geometry and single injection line, providing the most attractive option for an ion source for external injection into RHIC EBIS trap based on a ps-laser.

43 PARTICLE ACCELERATORS↗

The Los Alamos Neutron Science Center Spallation Neutron Sources

The Los Alamos Neutron Science Center (LANSCE) provides the scientific community with intense sources of neutrons, which can be used to perform experiments supporting civilian and national security research. These measurements include nuclear physics experiments for the defense program, basic science, and the radiation effect programs. This paper focuses on the radiation effects program, which involves mostly accelerated testing of semiconductor parts. When cosmic rays strike the earth's atmosphere, they cause nuclear reactions with elements in the air and produce a wide range of energetic particles. Because neutrons are uncharged, they can reach aircraft altitudes and sea level. These neutrons are thought to be the most important threat to semiconductor devices and integrated circuits. The best way to determine the failure rate due to these neutrons is to measure the failure rate in a neutron source that has the same spectrum as those produced by cosmic rays. Los Alamos has a high-energy and a low-energy neutron source for semiconductor testing. Both are driven by the 800-MeV proton beam from the LANSCE accelerator. The high-energy neutron source at the Weapons Neutron Research (WNR) facility uses a bare target that is designed to produce fast neutrons with energies from 100 keV to almost 800 MeV. The measured neutron energy distribution from WNR is very similar to that of the cosmic-ray-induced neutrons in the atmosphere. However, the flux provided at the WNR facility is typically 5×107 times more intense than the flux of the cosmic-ray-induced neutrons. This intense neutron flux allows testing at greatly accelerated rates. An irradiation test of less than an hour is equivalent to many years of neutron exposure due to cosmic-ray neutrons. The low-energy neutron source is located at the Lujan Neutron Scattering Center. It is based on a moderated source that provides useful neutrons from subthermal energies to ~100 keV. The characteristics of these sources, and ongoing industry program are described in this paper.

07 ISOTOPE AND RADIATION SOURCES↗

Mining Nontraditional Water Sources for a Distributed Hydrogen Economy

Securing decarbonized economies for energy and commodities will require abundant and widely available green H 2 . Ubiquitous wastewaters and nontraditional water sources could potentially feed water electrolyzers to produce this green hydrogen without competing with drinking water sources. Herein, we show that the energy and costs of treating nontraditional water sources such as municipal wastewater, industrial and resource extraction wastewater, and seawater are negligible with respect to those for water electrolysis. We also illustrate that the potential hydrogen energy that could be mined from these sources is vast. Based on these findings, we evaluate the implications of small-scale, distributed water electrolysis using disperse nontraditional water sources. Techno-economic analysis and life cycle analysis reveal that the significant contribution of H 2 transportation to costs and CO 2 emissions results in an optimal levelized cost of hydrogen at small- to moderate-scale water electrolyzer size. The implications of utilizing nontraditional water sources and decentralized or stranded renewable energy for distributed water electrolysis are highlighted for several hydrogen energy storage and chemical feedstock applications. Finally, we discuss challenges and opportunities for mining H 2 from nontraditional water sources to achieve resilient and sustainable economies for water and energy.

54 ENVIRONMENTAL SCIENCES↗

Electron source of triode type with radial converging electron flow for irradiation of cylindrical targets

Design of an electron source of triode type is described, which produces a radial converging electron beam employed for modification of the outer surface of fuel element claddings. Experimental investigations of the source showed that beam current magnitude, efficiency of beam focusing to the target, stability of source operation, and beam pulse duration become worse when the target diameter drops below certain values. A method for the calculation of the source operation was developed. Calculations showed that the reason of worse source operation is the initial angular spread of electrons when the target diameter is small. Because of the angular spread a part of electrons passes by the target and oscillates between the target and cathode. The space charge of the oscillating electrons lowers the emission current magnitude and leads to the formation of a virtual cathode in the grid-target gap despite the fact that the emission beam current is less than the limiting one. Formation of a virtual cathode is a reason for the unstable source operation and restriction of the beam pulse duration. Recommendations for the improvement of the source design are suggested.

43 PARTICLE ACCELERATORS↗

High intensity electron cyclotron resonance proton source for low energy high intensity proton accelerator

Electron cyclotron resonance (ECR) proton source at 50 keV, 50 mA has been designed, developed, and commissioned for the low energy high intensity proton accelerator (LEHIPA). Plasma characterization of this source has been performed. ECR plasma was generated with 400-1100 W of microwave power at 2.45 GHz, with hydrogen as working gas. Microwave was fed in the plasma chamber through quartz window. Plasma density and temperature was studied under various operating conditions, such as microwave power and gas pressure. Langmuir probe was used for plasma characterization using current voltage variation. The typical hydrogen plasma density and electron temperature measured were 7x10{sup 11} cm{sup -3} and 6 eV, respectively. The total ion beam current of 42 mA was extracted, with three-electrode extraction geometry, at 40 keV of beam energy. The extracted ion current was studied as a function of microwave power and gas pressure. Depending on source pressure and discharge power, more than 30% total gas efficiency was achieved. The optimization of the source is under progress to meet the requirement of long time operation. The source will be used as an injector for continuous wave radio frequency quadrupole, a part of 20 MeV LEHIPA. The required rms normalized emittance of this source is less than 0.2 {pi} mm mrad. The simulated value of normalized emittance is well within this limit and will be measured shortly. This paper presents the study of plasma parameters, first beam results, and the status of ECR proton source.

43 PARTICLE ACCELERATORS↗

Development of an H{sup -} ion source for Japan Proton Accelerator Research Complex upgrade

A cesium (Cs) free H{sup -} ion source driven with a lanthanum hexaboride (LaB{sub 6}) filament was adopted as an ion source for the first stage of the Japan Proton Accelerator Research Complex (J-PARC). At present, the maximum H{sup -} ion current produced by the ion source is 38 mA, using which J-PARC can produce a proton beam power of 0.6 MW by accelerating it with the 181 MeV linac and the 3 GeV rapid cycling synchrotron. In order to satisfy the beam power of 1 MW required for the second stage of the J-PARC in the near future, we have to increase the ion current to more than 60 mA. Therefore, we have started to develop a Cs-seeded ion source by adding an external Cs-seeding system to a J-PARC test ion source that has a structure similar to that of the J-PARC ion source except for the fact that the plasma chamber is slightly larger. As a result, a H{sup -} ion current of more than 70 mA was obtained from the ion source using a tungsten filament instead of a LaB{sub 6} filament with a low arc discharge power of 15 kW (100 V, 150 A).

43 PARTICLE ACCELERATORS↗

Characterization of Boron Contamination in Fluorine Implantation using Boron Trifluoride as a Source Material

Fluorine implantation process purity was considered on different types of high current implanters. It was found that implanters equipped with an indirectly heated cathode ion source show an enhanced deep boron contamination compared to a high current implanter using a cold RF-driven multicusp ion source when boron trifluoride is used for fluorine implantations. This contamination is directly related to the source technology and thus, should be considered potentially for any implanter design using hot cathode/hot filament ion source, independently of the manufacturer.The boron contamination results from the generation of double charged boron ions in the arc chamber and the subsequent charge exchange reaction to single charged boron ions taking place between the arc chamber and the extraction electrode. The generation of the double charged boron ions depends mostly on the source parameters, whereas the pressure in the region between the arc chamber and the extraction electrode is mostly responsible for the charge exchange from double charged to single charged ions. The apparent mass covers a wide range, starting at mass 11. A portion of boron ions with energies of (19/11) times higher than fluorine energy has the same magnetic rigidity as fluorine beam and cannot be separated by the analyzer magnet. The earlier described charge exchange effects between the extraction electrode and the entrance to the analyzer magnet, however, generates boron beam with a higher magnetic rigidity compared to fluorine beam and cannot cause boron contamination after mass-separation.The energetic boron contamination was studied as a function of the ion source parameters, such as gas flow, arc voltage, and source magnet settings, as well as analyzing magnet aperture resolution. This allows process optimization reducing boron contamination to the level acceptable for device performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The development of the radio frequency driven negative ion source for neutral beam injectors (invited)

Large and powerful negative hydrogen ion sources are required for the neutral beam injection (NBI) systems of future fusion devices. Simplicity and maintenance-free operation favors RF sources, which are developed intensively at the Max-Planck-Institut fuer Plasmaphysik (IPP) since many years. The negative hydrogen ions are generated by caesium-enhanced surface conversion of atoms and positive ions on the plasma grid surface. With a small scale prototype the required high ion current density and the low fraction of co-extracted electrons at low pressure as well as stable pulses up to 1 h could be demonstrated. The modular design allows extension to large source dimensions. This has led to the decision to choose RF sources for the NBI of the international fusion reactor, ITER. As an intermediate step towards the full size ITER source at IPP, the development will be continued with a half-size source on the new ELISE testbed. This will enable to gain experience for the first time with negative hydrogen ion beams from RF sources of these dimensions.

43 PARTICLE ACCELERATORS↗

New ion source for KSTAR neutral beam injection system

The neutral beam injection system (NBI-1) of the KSTAR tokamak can accommodate three ion sources; however, it is currently equipped with only one prototype ion source. In the 2010 and 2011 KSTAR campaigns, this ion source supplied deuterium neutral beam power of 0.7-1.6 MW to the KSTAR plasma with a beam energy of 70-100 keV. A new ion source will be prepared for the 2012 KSTAR campaign with a much advanced performance compared with the previous one. The newly designed ion source has a very large transparency ({approx}56%) without deteriorating the beam optics, which is designed to deliver a 2 MW injection power of deuterium beams at 100 keV. The plasma generator of the ion source is of a horizontally cusped bucket type, and the whole inner wall, except the cathode filaments and plasma grid side, functions as an anode. The accelerator assembly consists of four multi-circular aperture grids made of copper and four electrode flanges made of aluminum alloy. The electrodes are insulated using PEEK. The ion source will be completed and tested in 2011.

43 PARTICLE ACCELERATORS↗

Laser ion sources for radioactive beams (invited)

Resonant ionisation laser ion sources are nowadays extensively used, when available, at many leading on-line facilities. Moreover, new laser ion sources are now under development in most of the recent on-line facility projects under construction worldwide. This success is mainly due to the reliability, the ionization efficiency and the high purity that this type of source can achieve for the production of radioactive species and for a large range of chemical elements. Laser ion sources for radioactive beams gather many different systems such as dye laser or all-solid state titanium:sapphire laser systems, high or low repetition rates, hot cavities or gas cells, additional selectivity by using chemical techniques, or the LIST technique (laser ion source trap). In this paper, the physics of laser ion sources will be described with the current limitations and challenges for the future. An overview of the laser ion source facilities will be given, with an emphasis on the ongoing developments and perspectives on LIS.

43 PARTICLE ACCELERATORS↗

Ion source and injection line for high intensity medical cyclotron

A 14 MeV high intensity compact cyclotron, CYCIAE-14, was built at China Institute of Atomic Energy (CIAE). An injection system based on the external H− ion source was used on CYCIAE-14 so as to provide high intensity beam, while most positron emission tomography cyclotrons adopt internal ion source. A beam intensity of 100 μA/14 MeV was extracted from the cyclotron with a small multi-cusp H− ion source (CIAE-CH-I type) and a short injection line, which the H− ion source of 3 mA/25 keV H− beam with emittance of 0.3π mm mrad and the injection line of with only 1.2 m from the extraction of ion source to the medial plane of the cyclotron. To increase the extracted beam intensity of the cyclotron, a new ion source (CIAE-CH-II type) of 9.1 mA was used, with maximum of 500 μA was achieved from the cyclotron. The design and test results of the ion source and injection line optimized for high intensity acceleration will be given in this paper.

43 PARTICLE ACCELERATORS↗

Development of series H{sup −} multicusp ion source at China Institute of Atomic Energy

The development of H{sup −} multicusp ion sources has been carried out at China Institute of Atomic Energy (CIAE) for more than ten years. The first H{sup −} ion source with 5.2 mA was made in 2002. After improving the configured magnetic field, a H{sup −} ion source of 10 mA was made in 2004, and the beam intensity of 15 mA was obtained in 2008 after further improvements of the filter field. The beam intensity of 18 mA was achieved in 2010 following the in-depth study and optimization on some essential operation conditions. Now a series of H{sup −} cusp sources with different sizes and beam intensity ranging from 3 mA to 18 mA have been successfully developed at CIAE. All the ion sources can fast finish the test on the test stand now, since all the connections are modularized and can fit all kinds of H{sup −} mulitcusp source of CIAE. The development status of the various H{sup −} multicusp ion sources at CIAE are presented in the paper.

43 PARTICLE ACCELERATORS↗

Beam extraction and high stability operation of high current electron cyclotron resonance proton ion source

A high current electron cyclotron resonance proton ion source is designed and developed for the low energy high intensity proton accelerator at Bhabha Atomic Research Centre. The plasma discharge in the ion source is stabilized by minimizing the reflected microwave power using four stub auto tuner and magnetic field. The optimization of extraction geometry is performed using PBGUNS code by varying the aperture, shape, accelerating gap, and the potential on the electrodes. While operating the source, it was found that the two layered microwave window (6 mm quartz plate and 2 mm boron nitride plate) was damaged (a fine hole was drilled) by the back-streaming electrons after continuous operation of the source for 3 h at beam current of 20–40 mA. The microwave window was then shifted from the line of sight of the back-streaming electrons and located after the water-cooled H-plane bend. In this configuration the stable operation of the high current ion source for several hours is achieved. The ion beam is extracted from the source by biasing plasma electrode, puller electrode, and ground electrode to +10 to +50 kV, −2 to −4 kV, and 0 kV, respectively. The total ion beam current of 30–40 mA is recorded on Faraday cup at 40 keV of beam energy at 600–1000 W of microwave power, 800–1000 G axial magnetic field and (1.2–3.9) × 10{sup −3} mbar of neutral hydrogen gas pressure in the plasma chamber. The dependence of beam current on extraction voltage, microwave power, and gas pressure is investigated in the range of operation of the ion source.

43 PARTICLE ACCELERATORS↗

Roles of a plasma grid in a negative hydrogen ion source

The plasma grid is electrically biased with respect to other parts of source chamber wall in both volume sources and sources seeded with alkali metals. The roles of the plasma grid in these two kinds of sources will be described. The main functions of the plasma grid in volume sources are: optimizing the extracted negative ion current, reducing the co-extracted electron current, controlling the axial plasma potential profile, recycling the hydrogen atoms to molecules, concentrating the negative ions near its surface and, when biased positive, depleting the electron population near its surface. These functions are maintained in the sources seeded with alkali metals. However an additional function appears in the Cs seeded sources, namely direct emission of negative ions under positive ion and neutral hydrogen bombardment.

07 ISOTOPE AND RADIATION SOURCES↗

Extending the path for efficient extreme ultraviolet sources for advanced nanolithography

Developing efficient light sources for extreme ultraviolet (EUV) lithography is one of the most important problems of high volume manufacturing (HVM) of the next generation computer chips. Critical components of this technology are continued to face challenges in the demanding performance for HVM. Current investigations of EUV and beyond EUV (BEUV) community are focused on the dual-pulse laser produced plasma (LPP) using droplets of mass-limited targets. Two main objectives as well as challenges in the optimization of these light sources are related to enhancement of the conversion efficiency (CE) of the source and increase components lifetime of the collector optical system. These require significant experimental and computer simulation efforts. These requirements call for fine detail analysis of various plasma physics processes involved in laser target interactions and their effects on source optimization. We continued to enhance our comprehensive HEIGHTS simulation package and upgrade our CMUXE laboratories to study and optimize the efficiency of LPP sources. Integrated modeling and experimental research were done to both benchmark simulation results and to make projections and realistic predictions of the development path for powerful EUVL devices for HVM requirements. We continued the detail analysis of dual-pulse laser systems using various laser wavelengths and delay times between the two pulses. We showed that the efficiency of EUV sources can be improved utilizing the higher harmonics of Nd:YAG laser for the prepulse and the first harmonics for the main pulse, while still having lower efficiency than the combination involving CO{sub 2} laser in the range of parameters studied in this case. The differences in optimization process as well as in the source characteristics for two combinations of laser wavelengths were analyzed based on details of atomic and hydrodynamics processes during the evolving plasma plumes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-beam plasma source deposition of carbon thin films

A single-beam plasma source was developed and used to deposit hydrogenated amorphous carbon (a-C:H) thin films at room temperature. The plasma source was excited by a combined radio frequency and direct current power, which resulted in tunable ion energy over a wide range. The plasma source could effectively dissociate the source hydrocarbon gas and simultaneously emit an ion beam to interact with the deposited film. Using this plasma source and a mixture of argon and C 2 H 2 gas, a-C:H films were deposited at a rate of ~26 nm/min. The resulting a-C:H film of 1.2 µm thick was still highly transparent with a transmittance of over 90% in the infrared range and an optical bandgap of 2.04 eV. Young’s modulus of the a-C:H film was ~80 GPa. The combination of the low-temperature high-rate deposition of transparent a-C:H films with moderately high Young’s modulus makes the single-beam plasma source attractive for many coatings applications, especially in which heat-sensitive and soft materials are involved. Here, the single-beam plasma source can be configured into a linear structure, which could be used for large-area coatings.

14 SOLAR ENERGY↗