Search NASA⌕ Search

SEARCH · Search NASA

Results for “source characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Intrinsic Radiation Source Generation with the ISC Package: Data Comparisons and Benchmarking

The characterization of radioactive emissions from unstable isotopes (intrinsic radiation) is necessary for shielding and radiological-dose calculations from radioactive materials. While most radiation transport codes, e.g., MCNP [X-5 Monte Carlo Team, 2003], provide the capability to input user prescribed source definitions, such as radioactive emissions, they do not provide the capability to calculate the correct radioactive-source definition given the material compositions. Special modifications to MCNP have been developed in the past to allow the user to specify an intrinsic source, but these modification have not been implemented into the primary source base [Estes et al., 1988]. To facilitate the description of the intrinsic radiation source from a material with a specific composition, the Intrinsic Source Constructor library (LIBISC) and MCNP Intrinsic Source Constructor (MISC) utility have been written. The combination of LIBISC and MISC will be herein referred to as the ISC package. LIBISC is a statically linkable C++ library that provides the necessary functionality to construct the intrinsic-radiation source generated by a material. Furthermore, LIBISC provides the ability use different particle-emission databases, radioactive-decay databases, and natural-abundance databases allowing the user flexibility in the specification of the source, if one database is preferred over others. LIBISC also provides functionality for aging materials and producing a thick-target bremsstrahlung photon source approximation from the electron emissions. The MISC utility links to LIBISC and facilitates the description of intrinsic-radiation sources into a format directly usable with the MCNP transport code. Through a series of input keywords and arguments the MISC user can specify the material, age the material if desired, and produce a source description of the radioactive emissions from the material in an MCNP readable format. Further details of using the MISC utility can be obtained from the user guide [Solomon, 2012]. The remainder of this report presents a discussion of the databases available to LIBISC and MISC, a discussion of the models employed by LIBISC, a comparison of the thick-target bremsstrahlung model employed, a benchmark comparison to plutonium and depleted-uranium spheres, and a comparison of the available particle-emission databases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a Characterized Radiation Field for Evaluating Sensor Performance

Numerous efforts are funded by US agencies (DOE, DoD, DHS) for development of novel radiation sensing and measurement systems. An effort has been undertaken to develop a flexible shielding system compatible with a variety of sources (beta, X-ray, gamma, and neutron) that can be highly characterized using conventional radiation detection and measurement systems. Sources available for use in this system include americium-beryllium (AmBe), plutonium-beryllium (PuBe), strontium-90 (Sr-90), californium-252 (Cf-252), krypton-85 (Kr-85), americium-241 (Am-241), and depleted uranium (DU). Shielding can be varied by utilization of materials that include lexan, water, oil, lead, and polyethylene. Arrangements and geometries of source(s) and shielding can produce symmetrical or asymmetrical radiation fields. The system has been developed to facilitate accurately repeatable configurations. Measurement positions are similarly capable of being accurately re-created. Stand-off measurement positions can be accurately re-established using differential global positioning system (GPS) navigation. Instruments used to characterize individual measurement locations include a variety of sodium iodide (NaI(Tl)) (3 x 3 inch, 4 x 4 x 16 inch, Fidler) and lithium iodide (LiI(Eu)) detectors (for use with multichannel analyzer software) and detectors for use with traditional hand held survey meters such as boron trifluoride (BF{sub 3}), helium-3 ({sup 3}He), and Geiger-Mueller (GM) tubes. Also available are Global Dosimetry thermoluminescent dosimeters (TLDs), CR39 neutron chips, and film badges. Data will be presented comparing measurement techniques with shielding/source configurations. The system is demonstrated to provide a highly functional process for comparison/characterization of various detector types relative to controllable radiation types and levels. Particular attention has been paid to use of neutron sources and measurements. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Paracousti-UQ: A Stochastic 3-D Acoustic Wave Propagation Algorithm.

Acoustic full waveform algorithms, such as Paracousti, provide deterministic solutions in complex, 3-D variable environments. In reality, environmental and source characteristics are often only known in a statistical sense. Thus, to fully characterize the expected sound levels within an environment, this uncertainty in environmental and source factors should be incorporated into the acoustic simulations. Performing Monte Carlo (MC) simulations is one method of assessing this uncertainty, but it can quickly become computationally intractable for realistic problems. An alternative method, using the technique of stochastic partial differential equations (SPDE), allows computation of the statistical properties of output signals at a fraction of the computational cost of MC. Paracousti-UQ solves the SPDE system of 3-D acoustic wave propagation equations and provides estimates of the uncertainty of the output simulated wave field (e.g., amplitudes, waveforms) based on estimated probability distributions of the input medium and source parameters. This report describes the derivation of the stochastic partial differential equations, their implementation, and comparison of Paracousti-UQ results with MC simulations using simple models.

97 MATHEMATICS AND COMPUTING↗

COLLABORATIVE RESEARCH: Study of Aerosol Sources and Processing at the GVAX Pantnagar Supersite

This project funded the participation of scientists from seven research groups, running more than thirty instruments, in the Winter Intensive Operating Period (January-February 2012) of the Clean Air for London (ClearfLo) campaign at a rural site in Detling, UK, 45 km southeast of central London. The primary science questions for the ClearfLo Winter IOP were, 1) what is the urban increment of particulate matter (PM) and other pollutants in the greater London area, and, 2) what is the contribution of solid fuel use for home heating to wintertime PM? An additional motivation for the Detling measurements was the question of whether coatings on black carbon particles enhance absorption. The following four key accomplishments have been identified so far: 1) Chemical, physical and optical characterization of PM from local and regional sources (Figures 2, 4, 5 and 6). 2) Measurement of urban increment in particulate matter and gases in London (Figure 3). 3) Measurement of optical properties and chemical composition of coatings on black carbon containing particles indicates absorption enhancement. 4) First deployment of chemical ionization instrument (MOVI-CI-TOFMS) to measure both particle-phase and gas-phase organic acids. (See final report from Joel Thornton, University of Washington, for details.) Analysis of the large dataset acquired in Detling is ongoing and will yield further key accomplishments. These measurements of urban and rural aerosol properties will contribute to improved modeling of regional aerosol emissions, and of atmospheric aging and removal. The measurement of absorption enhancement by coatings on black carbon will contribute to improved modeling of the direct radiative properties of PM.

54 ENVIRONMENTAL SCIENCES↗

Environmental Sources of Bacteria Differentially Influence Host-Associated Microbial Dynamics

ABSTRACT Host-associated microbial dynamics are influenced by dietary and immune factors, but how exogenous microbial exposure shapes host-microbe dynamics remains poorly characterized. To investigate this phenomenon, we characterized the skin, rectum, and respiratory tract-associated microbiota in four aquarium-housed dolphins daily over a period of 6 weeks, including administration of a probiotic during weeks 4 to 6. The environmental bacterial sources were also characterized, including the animals’ human handlers, the aquarium air and water, and the dolphins’ food supply. Continuous microbial exposure occurred between all sites, yet each environment maintained a characteristic microbiota, suggesting that the majority of exposure events do not result in colonization. Small changes in water physicochemistry had a significant but weak correlation with change in dolphin-associated bacterial richness but had no influence on phylogenetic diversity. Food and air microbiota were the richest and had the largest conditional influence on other microbiota in the absence of probiotics, but during probiotic administration, food alone had the largest influence on the stability of the dolphin microbiota. Our results suggest that respiratory tract and gastrointestinal epithelium interactions with air- and food-associated microbes had the biggest influence on host-microbiota dynamics, while other interactions, such as skin transmission, played only a minor role. Finally, direct oral stimulation with a foreign exogenous microbial source can have a profound effect on microbial stability. IMPORTANCE Furthermore, these results provide valuable insights into the ecological influence of exogenous microbial exposure, as well as laying the foundation for improving aquarium management practices. By comparing data for dolphins from aquaria that use natural versus artificial seawater, we demonstrate the potential influence of aquarium water disinfection procedures on dolphin microbial dynamics.

59 BASIC BIOLOGICAL SCIENCES↗

Investigation of Neutron Detector Response to Varying Temperature and Water Content for Geothermal Applications

Nuclear logging techniques have been used for oil well logging applications for decades. The basic principle is to use a neutron and/or photon source and neutron and photon detectors for characterization purposes. Although the technology has matured, it is not directly applicable to geothermal logging due to even more challenging environmental conditions, both in terms of temperature and pressure. For geothermal logging, the operating temperature can go up to 376 C for depths up to 10,000 km. In this paper, the preliminary computational results for thermal neutron detector response for varying temperature and water content for geothermal applications are presented. In this summary, preliminary results for neutron detector response for varying formation temperature and water content are presented. The analysis is performed for a steady state source (AmBe) and time dependent source (PNG) in pulsed mode. The computational results show significant sensitivity to water content as well as temperature changes for both steady state and time dependent measurements. As expected, the most significant change is due to the temperature change for S({alpha}, {beta}) nuclear data instead of individual isotope cross sections for the formation. Clearly, this is partially because of the fact that strong absorbers (i.e., chlorine) are not taken into account for the analysis at this time. The computational analysis was performed using the temperature dependent data in the ENDF/B-VII libraries, supplied with MCNP. Currently, the data for intermediate temperatures are being generated using NJOY and validated. A series of measurements are planned to validate the computational results. Further measurements are planned to determine the neutron and photon detector response as a function of temperature. The tests will be performed for temperatures up to 400 C.

02 PETROLEUM↗

New Methods to Produce and Extend the Spectral Range of Photocathodes for Large Area Photodetectors with mm scale Space Resolution (Final Report)

Cornell group has developed recipes to grow photocathodes belonging to the alkali antimonide family using evaporation from elemental sources with and without line of sight between the sources and the glass substrate. Photocathodes were characterized in terms of their quantum efficiency in the spectral range covering the visible and the near infrared part of the spectrum. Two different approaches have been used to demonstrate the growth of high quantum efficiency photocathodes: the first approach makes use of elemental antimony and alkali metals loaded into ceramic crucibles hosted into effusion cells like the one used in molecular beam epitaxy reactors; whereas in the second approach the antimony film is evaporated onto the transparent substrate using effusion cells and then transferred into a different reaction chamber where exposure to the alkali metals coming from an elemental source lacking the line of sight to the substrate is used to produce the photocathode material. The research conducted opens the exploration of alternative methods for the synthesis of photocathodes specifically designed to be implemented over large areas maximizing the production throughput and lowering the cost. It particular, this research can benefit future HEP programs by providing new methods that can be adopted to produce photon detectors for future experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiochromic film imaging spectroscopy of laser-accelerated proton beams

This article reports on an experimental method to fully reconstruct laser-accelerated proton beam parameters called radiochromic film imaging spectroscopy (RIS). RIS allows for the characterization of proton beams concerning real and virtual source size, envelope- and microdivergence, normalized transverse emittance, phase space, and proton spectrum. This technique requires particular targets and a high resolution proton detector. Therefore thin gold foils with a microgrooved rear side were manufactured and characterized. Calibrated GafChromic radiochromic film (RCF) types MD-55, HS, and HD-810 in stack configuration were used as spatial and energy resolved film detectors. The principle of the RCF imaging spectroscopy was demonstrated at four different laser systems. This can be a method to characterize a laser system with respect to its proton-acceleration capability. In addition, an algorithm to calculate the spatial and energy resolved proton distribution has been developed and tested to get a better idea of laser-accelerated proton beams and their energy deposition with respect to further applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Critical mineral source potential from oil & gas produced waters in the United States

The volume of produced water, a by-product of oil & gas operations and other energy processes, has been growing across the United States (U.S.) along with the need to manage or recycle this wastewater. Produced water contains many naturally occurring elements of varying concentrations, including critical minerals which are essential to the clean energy transition. However, the current understanding of critical mineral concentrations in produced water and the associated volumes across the U.S. is limited. This study has assessed available databases and literature to gain insight into the presence and concentration of five high priority critical minerals, namely cobalt, lithium, magnesium, manganese, and nickel. The U.S. Geological Survey's National Produced Waters Geochemical Database was the main data source used for determining average critical mineral concentrations in produced water from the major oil and gas reservoirs in the U.S. The volumes of produced water for these major reservoirs were coupled with these concentrations to provide insights into where critical minerals are likely to have high abundance and therefore more recovery options. The analysis indicated the highest recovery potential for lithium and magnesium from produced water in the Permian basin and the Marcellus shale region. However, these assessments should be considered conservative due to the limited availability of reliable concentration data. Finally, it is expected more critical mineral recovery options could emerge with comprehensive characterization data from more recent and representative sources of produced water.

54 ENVIRONMENTAL SCIENCES↗

A Mo-anode-based in-house source for small-angle X-ray scattering measurements of biological macromolecules

We demonstrate the use of a molybdenum-anode-based in-house small-angle X-ray scattering (SAXS) setup to study biological macromolecules in solution. Our system consists of a microfocus X-ray tube delivering a highly collimated flux of 2.5 × 10{sup 6} photons/s at a beam size of 1.2 × 1.2 mm{sup 2} at the collimation path exit and a maximum beam divergence of 0.16 mrad. The resulting observable scattering vectors q are in the range of 0.38 Å{sup −1} down to 0.009 Å{sup −1} in SAXS configuration and of 0.26 Å{sup −1} up to 5.7 Å{sup −1} in wide-angle X-ray scattering (WAXS) mode. To determine the capabilities of the instrument, we collected SAXS data on weakly scattering biological macromolecules including proteins and a nucleic acid sample with molecular weights varying from ∼12 to 69 kDa and concentrations of 1.5–24 mg/ml. The measured scattering data display a high signal-to-noise ratio up to q-values of ∼0.2 Å{sup −1} allowing for an accurate structural characterization of the samples. Moreover, the in-house source data are of sufficient quality to perform ab initio 3D structure reconstructions that are in excellent agreement with the available crystallographic structures. In addition, measurements for the detergent decyl-maltoside show that the setup can be used to determine the size, shape, and interactions (as characterized by the second virial coefficient) of detergent micelles. This demonstrates that the use of a Mo-anode based in-house source is sufficient to determine basic geometric parameters and 3D shapes of biomolecules and presents a viable alternative to valuable beam time at third generation synchrotron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of SAMMY for Non-Destructive Characterization of Irradiated Samples Using Neutron Transmission Measurements at VENUS

This report presents the application of SAMMY (Larson 2008), an R-matrix Bayesian fitting system, for analyzing neutron transmission data to enable non-destructive isotopic identification. Transmission measurements were conducted at the VENUS (Bilheux et al. 2023) beamline of the Spallation Neutron Source (SNS) using samples with unknown or partially characterized compositions. Through the application of SAMMY’s R-matrix Bayesian fitting capabilities to the measured transmission spectra and comparison against evaluated nuclear data libraries, isotopic constituents can be quantitatively determined based on their characteristic neutron resonance signatures. This methodology demonstrates significant potential for applications in nuclear safeguards, forensics, and post-irradiation examination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Emission factors of industrial boilers burning biomass-derived fuels

Boilers are combustion devices that provide process heat and are integral to many industrial facilities. Historically, outside of the pulp and paper industry, most boilers burned fossil fuels, although interest in decarbonization has been leading to an increased use of renewable fuels in boilers. These boilers, including those in the biorefineries, are often large sources of air pollutant emissions, and the characterization of these emissions is critical to obtaining air permits and ensuring protection of the surrounding air quality. Several industrial boilers and new biorefineries allow utilization of biomass-derived fuels (e.g. wastewater sludge, lignin, etc.) produced during their operation as a fuel for the boiler to meet process energy needs. However, there is limited empirical data on emission factors for the burning of unconventional fuels, such as solid-gas mixtures containing biomass residues. To fill this gap, we carry out a comprehensive data survey, collecting information on emission factors for boilers burning either a single or a mixture of solid and gaseous biomass-derived fuels. We review multiple hard-to-obtain and unconventional data sources, such as air permit applications, stack test data, and industry-sponsored data collection efforts, to compile emission factors for biomass-derived fuels. We then compare this data with wood residue emission factors from the U.S. Environmental Protection Agency’s AP-42 emission factor database. Our results indicate that the emission factors for boilers burning unconventional fuels vary widely depending on the fuel composition, boiler type, and fuel characteristics. Overall, we find that median emission factors of selected biomass-derived fuels are typically lower than those of wood residue boilers in AP-42. The information collected herein could be useful to permitting agencies and industries utilizing boilers who may want to reduce the carbon impact of their facilities by combusting biomass-derived wastes for process energy needs, for more accurate emission estimation for permitting.

09 BIOMASS FUELS↗

Flat Field Anomalies in an X-ray CCD Camera Measured Using a Manson X-ray Source (HTPD 08 paper)

The Static X-ray Imager (SXI) is a diagnostic used at the National Ignition Facility (NIF) to measure the position of the X-rays produced by lasers hitting a gold foil target. The intensity distribution taken by the SXI camera during a NIF shot is used to determine how accurately NIF can aim laser beams. This is critical to proper NIF operation. Imagers are located at the top and the bottom of the NIF target chamber. The CCD chip is an X-ray sensitive silicon sensor, with a large format array (2k x 2k), 24 {micro}m square pixels, and 15 {micro}m thick. A multi-anode Manson X-ray source, operating up to 10kV and 10W, was used to characterize and calibrate the imagers. The output beam is heavily filtered to narrow the spectral beam width, giving a typical resolution E/{Delta}E {approx} 10. The X-ray beam intensity was measured using an absolute photodiode that has accuracy better than 1% up to the Si K edge and better than 5% at higher energies. The X-ray beam provides full CCD illumination and is flat, within {+-}1% maximum to minimum. The spectral efficiency was measured at 10 energy bands ranging from 930 eV to 8470 eV. We observed an energy dependent pixel sensitivity variation that showed continuous change over a large portion of the CCD. The maximum sensitivity variation occurred at 8470 eV. The geometric pattern did not change at lower energies, but the maximum contrast decreased and was not observable below 4 keV. We were also able to observe debris, damage, and surface defects on the CCD chip. The Manson source is a powerful tool for characterizing the imaging errors of an X-ray CCD imager. These errors are quite different from those found in a visible CCD imager.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of soils from an industrial complex contaminated with elemental mercury

Historical use of liquid elemental mercury (Hg(0){sub l}) at the Y-12 National Security Complex in Oak Ridge, TN, USA, resulted in large deposits of Hg(0){sub l} in the soils. The fate and distribution of the spilled Hg(0) are not well characterized. In this study we evaluated analytical tools for characterizing the speciation of Hg in the contaminated soils and then used the analytical techniques to examine the speciation of Hg in two soil cores collected at the site. These include x-ray fluorescence (XRF), soil Hg(0) headspace analysis, and total Hg determination by acid digestion coupled with cold vapor atomic absorption (HgT). XRF was not found to be suitable for evaluating Hg concentrations in heterogeneous soils containing low concentration of Hg or Hg(0) because Hg concentrations determined using this method were lower than those determined by HgT analysis and the XRF detection limit is 20 mg/kg. Hg(0){sub g} headspace analysis coupled with HgT measurements yielded good results for examining the presence of Hg(0){sub l} in soils and the speciation of Hg. The two soil cores are highly heterogeneous in both the depth and extent of Hg contamination, with Hg concentrations ranging from 0.05 to 8400 mg/kg. In the first core, Hg(0){sub l} was distributed throughout the 3.2 m depth, whereas the second core, from a location 12 m away, contained Hg(0){sub l} in a 0.3 m zone only. Sequential extractions showed organically associated Hg dominant at depths with low Hg concentration. Soil from the zone of groundwater saturation showed reducing conditions and the Hg is likely present as Hg-sulfide species. At this depth, lateral Hg transport in the groundwater may be a source of Hg detected in the soil at the deeper soil depths. Overall, characterization of soils containing Hg(0){sub l} is difficult because of the heterogeneous distribution of Hg within the soils. This is exacerbated in industrial facilities where fill materials make up much of the soils and historical and continued reworking of the subsurface has remobilized the Hg. -- Highlights: • Presence of Hg(0) and chemical transformations control the Hg speciation in soil. • Redox reactions can result in the mobilization and sequestration of Hg in soils. • Analysis of soils containing Hg(0) is complex due to sample heterogeneity.

60 APPLIED LIFE SCIENCES↗

Natural mercury isotope variation in coal deposits and organic soils

There is a need to distinguish among sources of Hg to the atmosphere in order to more fully understand global Hg pollution. In this study we investigate whether coal deposits within the United States, China, and Russia-Kazakhstan, which are three of the five greatest coal-producing regions, have diagnostic Hg isotopic fingerprints that can be used to discriminate among Hg sources. We also investigate the Hg isotopic composition of modern organic soil horizons developed in areas distant from point sources of Hg in North America. Mercury stored in coal deposits displays a wide range of both mass dependent fractionation and mass independent fractionation. {delta}{sup 202}Hg varies in coals by 3{per_thousand} and {Delta}{sup 201}Hg varies by 0.9{per_thousand}. Combining these two Hg isotope signals results in what may be a unique isotopic 'fingerprint' for many coal deposits. Mass independent fractionation of mercury has been demonstrated to occur during photochemical reactions of mercury. This suggests that Hg found in most coal deposits was subjected to photochemical reduction near the Earth's surface prior to deposition. The similarity in MDF and MIF of modern organic soils and coals from North America suggests that Hg deposition from coal may have imprinted an isotopic signature on soils. This research offers a new tool for characterizing mercury inputs from natural and anthropogenic sources to the atmosphere and provides new insights into the geochemistry of mercury in coal and soils. 35 refs., 2 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Test particle simulation of the role of ballistic electrons in hybrid dc/rf capacitively coupled plasmas in argon

Hybrid dc/rf plasma sources are an emerging equipment technology in plasma etching for semiconductor manufacturing. In this work, test particle simulations are used to describe the nature and role of the ballistic electrons, which originate as secondary electrons on a dc/rf (i.e., VHF, 60 MHz) biased upper electrode and are then accelerated in the sheath toward the opposite non-dc biased lower electrode. This opposite electrode, on which a wafer is placed, may have rf bias power applied to it at low frequencies. 2 MHz is typical. While a hybrid dc/rf plasma source is sustained by the VHF power source, simulations reveal ballistic electrons assist in the production of a plasma characterized by a relatively high ionization rate constant, especially in the dc sheath. The dc source helps to provide a source of high energy electrons that may reach the wafer. However, when the rf bias is applied on the lower electrode, ballistic electrons are confined in the potential well formed between electrodes and easily thermalized in the bulk. The simulated electron density dependencies on the dc bias and lower electrode rf power describe a dual mode source and are consistent with measured data. When no rf power is applied on the electrode opposite to the dc power source, the bulk electron density drops with increasing dc power at constant VHF power; when rf power is applied to the electrode opposite to the dc power source, the bulk electron density increases with dc power at constant VHF power. The fraction of electrons significantly above thermal reaching the wafer is much higher when no rf power is applied at the lower electrode but the total flux lower. Depending on its level, rf power applied to the wafer may effectively suppress the number of ballistic electrons that reach the wafer. Finally, the ionization rate constant due to ballistic electrons can be fitted as a simple function of the electric field in the dc sheath.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flat Field Anomalies in an X-Ray CCD Camera Measured Using a Manson X-Ray Source

The Static X-ray Imager (SXI) is a diagnostic used at the National Ignition Facility (NIF) to measure the position of the X-rays produced by lasers hitting a gold foil target. It determines how accurately NIF can point the laser beams and is critical to proper NIF operation. Imagers are located at the top and the bottom of the NIF target chamber. The CCD chip is an X-ray sensitive silicon sensor, with a large format array (2k x 2k), 24 μm square pixels, and 15 μm thick. A multi-anode Manson X-ray source, operating up to 10kV and 2mA, was used to characterize and calibrate the imagers. The output beam is heavily filtered to narrow the spectral beam width, giving a typical resolution E/ΔE≈12. The X-ray beam intensity was measured using an absolute photodiode that has accuracy better than 1% up to the Si K edge and better than 5% at higher energies. The X-ray beam provides full CCD illumination and is flat, within ±1.5% maximum to minimum. The spectral efficiency was measured at 10 energy bands ranging from 930 eV to 8470 eV. The efficiency pattern follows the properties of Si. The maximum quantum efficiency is 0.71. We observed an energy dependent pixel sensitivity variation that showed continuous change over a large portion of the CCD. The maximum sensitivity variation was >8% at 8470 eV. The geometric pattern did not change at lower energies, but the maximum contrast decreased and was less than the measurement uncertainty below 4 keV. We were also able to observe debris on the CCD chip. The debris showed maximum contrast at the lowest energy used, 930 eV, and disappeared by 4 keV. The Manson source is a powerful tool for characterizing the imaging errors of an X-ray CCD imager. These errors are quite different from those found in a visible CCD imager.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

COMPARISON OF MAGNETIC PROPERTIES IN A MAGNETIC CLOUD AND ITS SOLAR SOURCE ON 2013 APRIL 11–14

In the context of the Sun–Earth connection of coronal mass ejections and magnetic flux ropes (MFRs), we studied the solar active region (AR) and the magnetic properties of magnetic cloud (MC) event during 2013 April 14–15. We use in situ observations from the Advanced Composition Explorer and source AR measurements from the Solar Dynamics Observatory . The MCs magnetic structure is reconstructed from the Grad–Shafranov method, which reveals a northern component of the axial field with left handed helicity. The MC invariant axis is highly inclined to the ecliptic plane pointing northward and is rotated by 117° with respect to the source region PIL. The net axial flux and current in the MC are comparatively higher than from the source region. Linear force-free alpha distribution (10{sup −7}–10{sup −6} m{sup −1}) at the sigmoid leg matches the range of twist number in the MC of 1–2 au MFR. The MFR is nonlinear force-free with decreasing twist from the axis (9 turns/au) toward the edge. Therefore, a Gold–Hoyle (GH) configuration, assuming a constant twist, is more consistent with the MC structure than the Lundquist configuration of increasing twist from the axis to boundary. As an indication of that, the GH configuration yields a better fitting to the global trend of in situ magnetic field components, in terms of rms, than the Lundquist model. These cylindrical configurations improved the MC fitting results when the effect of self-similar expansion of MFR was considered. For such twisting behavior, this study suggests an alternative fitting procedure to better characterize the MC magnetic structure and its source region links.

79 ASTRONOMY AND ASTROPHYSICS↗