Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Modern deep neural networks for Direct Normal Irradiance forecasting: A classification approach

The escalating energy demand and the adverse environmental impacts of fossil-fuel use necessitate a shift towards cleaner and renewable alternatives. Concentrated Solar Power (CSP) technology emerges as a promising solution, offering a carbon-free alternative for power generation. The efficiency and profitability of CSP depend on the Direct Normal Irradiance (DNI) component of solar radiation; hence, accurate DNI forecasting can help optimize CSP plants’ operations and performance. The unpredictable nature of weather phenomena, particularly cloud cover, introduces uncertainty into DNI projections. Existing DNI forecasting models use meteorological factors, which are both challenging to estimate numerically over short prediction windows and expensive to model through data at a sufficiently high spatial and temporal resolution. This research addresses the challenge by presenting a novel approach that formulates DNI prediction as a multi-class classification problem, departing from conventional regression-based methods. The primary objective of this classification framework is to identify optimal periods aligning with specific operational thresholds for CSP plants, contributing to enhanced dispatch optimization strategies. We model the DNI classification problem using four advanced deep neural networks – rectified linear unit (ReLU) networks, 1D residual networks (ResNets), bidirectional long short-term memory (BiLSTM) networks, and transformers – achieving accuracies up to 93.5% without requiring meteorological parameters.

14 SOLAR ENERGY↗

Separable physics-informed DeepONet: Breaking the curse of dimensionality in physics-informed machine learning

The deep operator network (DeepONet) has shown remarkable potential in solving partial differential equations (PDEs) by mapping between infinite-dimensional function spaces using labeled datasets. However, in scenarios lacking labeled data, the physics-informed DeepONet (PI-DeepONet) approach, which utilizes the residual loss of the governing PDE to optimize the network parameters, faces significant computational challenges, particularly due to the curse of dimensionality. This limitation has hindered its application to high-dimensional problems, making even standard 3D spatial with 1D temporal problems computationally prohibitive. Additionally, the computational requirement increases exponentially with the discretization density of the domain. Here, to address these challenges and enhance scalability for high-dimensional PDEs, we introduce the Separable physics-informed DeepONet (Sep-PI-DeepONet). This framework employs a factorization technique, utilizing sub-networks for individual one-dimensional coordinates, thereby reducing the number of forward passes and the size of the Jacobian matrix required for gradient computations. By incorporating forward-mode automatic differentiation (AD), we further optimize computational efficiency, achieving linear scaling of computational cost with discretization density and dimensionality, making our approach highly suitable for high-dimensional PDEs. We demonstrate the effectiveness of Sep-PI-DeepONet through three benchmark PDE models: the viscous Burgers’ equation, Biot’s consolidation theory, and a parameterized heat equation. Our framework maintains accuracy comparable to the conventional PI-DeepONet while reducing training time by two orders of magnitude. Notably, for the heat equation solved as a 4D problem, the conventional PI-DeepONet was computationally infeasible (estimated 289.35 h), while the Sep-PI-DeepONet completed training in just 2.5 h. These results underscore the potential of Sep-PI-DeepONet in efficiently solving complex, high-dimensional PDEs, marking a significant advancement in physics-informed machine learning.

Neural operator↗

Model-based CT performance assessment and optimization for iodinated and noniodinated imaging tasks as a function of kVp and body size

Purpose: The goal of this study was to assess the comparative performance of iterative reconstruction in space (IRIS) and filtered back projection (FBP) reconstruction algorithms in terms of image quality and dose across kVps and phantom sizes. Methods: The ACR CT phantom (model 464) was supplemented with the addition of an iodinated spherical capsule (1.5 mm diameter, 3.4 mg iodine per ml) to simulate the contrast filled structures and with an additional circular attachment consisting of an array of 500 um brass beads for spatial resolution measurements. A larger sized phantom was also created by wrapping the original phantom with additional tissue equivalent material of 4 cm thickness. The phantoms were imaged on a 64 detector array multidetector computed tomography scanner (Somatom Definition, Siemens, Germany) using clinically applicable protocols (0.5 s rotation time; 80, 100, 120, and 140 kVp; 64 to 640 mA; 220 to 250 mm field of view). Images were reconstructed using the FBP and the IRIS algorithms. Combining measurements of image noise and spatial resolution with a task function, a figure of merit (FOM) for image quality was generated taking into account the type of visualization required from the image for the detection of either large or small image features with and without iodine content. The FOM was further reported in terms of area under the receiver operating characteristic (ROC) curve (A{sub Z}) to predict the comparative diagnostic performance of the two algorithms at different dose levels. Results: For a given dose level, the predicted A{sub Z} for IRIS consistently outperformed that of FBP. At comparative A{sub Z}, depending on protocol and task, the dose requirement for the optimal technique (optimized kVp with IRIS) was 2-3 times lower than that for standard technique (120 kVp with FBP). The potential for dose reduction was found to be higher when performing small feature detection tasks in comparison to larger feature detection tasks. The optimal kVp was from 80 to 100 kVp for the small phantom, 100 to 120 kVp for the larger phantom. Conclusions: Overall, greater dose reduction may be achieved with IRIS compared to FBP, with enhanced advantage at thinner slice reconstructions. The results highlight how IRIS may offer a superior balance between image quality and dose across a range of imaging tasks, thus enabling dose reduction at constant quality or image quality improvement at constant dose. The prediction of the investigation can be used toward effective design of subsequent clinical studies.

60 APPLIED LIFE SCIENCES↗

Demonstration and Optimization of a Drive Laser for an X-Band Photoinjector

Recently, a drive laser for an S-band (2.86 GHz) rf photoinjector, designed to provide a pulse that has a flat temporal and spatial profile, has been built, commissioned, and put into service as part of the LLNL Compton-scattering monoenergetic {gamma}-ray source program. This laser is based on an all-fiber oscillator and front-end amplification system, and provides both the laser light to generate the electrons as well as the rf signal that is amplified to accelerate them. Now, a new 11.424 GHz photoinjector is being developed, which has required a revised design for the laser system. The higher frequency has placed more stringent requirements on the synchronization stability, delivered pulse length, and pulse rise times to maintain the desired emittance. Presented here are the overall design and measured performance of the current system and a discussion of what changes are being made to address observed shortcomings and more demanding requirements to make the system ready for the next-generation Compton-scattering monoenergetic {gamma}-ray source.

42 ENGINEERING↗

SU-D-12A-06: A Comprehensive Parameter Analysis for Low Dose Cone-Beam CT Reconstruction

Purpose: There is always a parameter in compressive sensing based iterative reconstruction (IR) methods low dose cone-beam CT (CBCT), which controls the weight of regularization relative to data fidelity. A clear understanding of the relationship between image quality and parameter values is important. The purpose of this study is to investigate this subject based on experimental data and a representative advanced IR algorithm using Tight-frame (TF) regularization. Methods: Three data sets of a Catphan phantom acquired at low, regular and high dose levels are used. For each tests, 90 projections covering a 200-degree scan range are used for reconstruction. Three different regions-of-interest (ROIs) of different contrasts are used to calculate contrast-to-noise ratios (CNR) for contrast evaluation. A single point structure is used to measure modulation transfer function (MTF) for spatial-resolution evaluation. Finally, we analyze CNRs and MTFs to study the relationship between image quality and parameter selections. Results: It was found that: 1) there is no universal optimal parameter. The optimal parameter value depends on specific task and dose level. 2) There is a clear trade-off between CNR and resolution. The parameter for the best CNR is always smaller than that for the best resolution. 3) Optimal parameters are also dose-specific. Data acquired under a high dose protocol require less regularization, yielding smaller optimal parameter values. 4) Comparing with conventional FDK images, TF-based CBCT images are better under a certain optimally selected parameters. The advantages are more obvious for low dose data. Conclusion: We have investigated the relationship between image quality and parameter values in the TF-based IR algorithm. Preliminary results indicate optimal parameters are specific to both the task types and dose levels, providing guidance for selecting parameters in advanced IR algorithms. This work is supported in part by NIH (1R01CA154747-01)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wind-Optimal Lateral Trajectories for a Multirotor Aircraft in Urban Air Mobility

The primary motivation for this paper is to quantify the operational benefits (energy consumption and flight duration) of flying wind-optimal lateral trajectories for short flights (less than 60 miles) anticipated in the urban environment. The optimal control model presented includes a wind model for quantifying the effect of wind on the lateral trajectory. The optimal control problem is numerically solved using the direct collocation method. Energy consumption and flight duration flying wind-optimal lateral trajectories are compared with corresponding values obtained flying great-circle paths between the same origin and destination pairs to determine the operational benefits of wind-optimal routing for short flights. The flight duration results for different scenarios are validated using a simulation tool designed and developed at NASA for exploring advanced air traffic management concepts. This research study suggests that for short flights in an urban environment, operational benefits of the wind-optimal lateral trajectories over the corresponding great-circle trajectories in terms of energy consumption and flight duration per flight are dependent on: i) wind field’s spatial variability, ii) wind magnitude, iii) the direction of route relative to the wind field, and iv) cruise segment length. The operational benefits observed in realistic flyable wind scenarios are less than 2.5%; these could be translated to an equivalent of a maximum of 2 min of cruise flight duration savings in the urban air mobility environment. As expected, headwinds and tailwinds along the flight route most significantly impact energy consumption and flight duration.

Wind-Optimal Trajectory, Lateral Path, Urban Air M↗

Aeroservoelastic Optimization under Stochastic Gust Constraints

This work considers the aeroservoelastic optimization of a highly flexible transport aircraft wingbox with several control surfaces distributed along the trailing edge. The steady deflections of the control surfaces are designed to alleviate static maneuver loads, while the unsteady deflections are designed to alleviate stochastic continuous gust disturbances. Spatially-detailed unsteady stochastic stress and panel buckling constraints are formulated via modal acceleration, and by methods to locate the most-probable failure point along an equal-probability hypersurface. For the case considered here, it is found that the inclusion of such gust constraints during optimization presents a sizable structural mass penalty. In some cases, this mass penalty can be completely recovered with controlled gust load alleviation.

Stanford, Bret K.↗

Silicon-on-glass pore network micromodels with oxygen-sensing fluorophore films for chemical imaging and defined spatial structure

Pore network microfluidic models were fabricated by a silicon-on-glass technique that provides the precision advantage of dry etched silicon while creating a structure that is transparent across all microfluidic channels and pores, and can be imaged from either side. A silicon layer is bonded to an underlying borosilicate glass substrate and thinned to the desired height of the microfluidic channels and pores. The silicon is then patterned and through-etched by deep reactive ion etching (DRIE), with the underlying glass serving as an etch stop. After bonding on a transparent glass cover plate, one obtains a micromodel in oxygen impermeable materials with water wet surfaces where the microfluidic channels are transparent and structural elements such as the pillars creating the pore network are opaque. The micromodel can be imaged from either side. The advantageous features of this approach in a chemical imaging application are demonstrated by incorporating a Pt porphyrin fluorophore in a PDMS film serving as the oxygen sensing layer and a bonding surface, or in a polystyrene film coated with a PDMS layer for bonding. The sensing of a dissolved oxygen gradient was demonstrated using fluorescence lifetime imaging, and it is shown that different matrix polymers lead to optimal use in different ranges dissolved oxygen concentration. Imaging with the opaque pillars in between the observation direction and the continuous fluorophore film yields images that retain spatial information in the sensor image.

chemical imaging↗

Muon track reconstruction in a segmented bolometric array using multi-objective optimization

Recent advances in segmented solid-state detector arrays for rare-event searches have allowed the technology to approach the ton-scale in detector mass and the scale of meters in size. Often focused around searches for neutrinoless double-beta decay or direct dark matter detection, such experiments also have the capability to search for exotic particles that leave track-like signatures across their volume. However, the segmented nature of such detector arrays often sets the spatial resolution and makes the problem of reconstructing track-like paths non-trivial. Here, in this paper, we present an algorithm that improves reconstruction of track-like events in segmented detectors using multi-objective optimization — a computational technique that optimizes more than one cost function at a time without specifying a quantitative weighting between them. Such a technique allows the reconstruction of tracks through a detector and the determination of path-lengths through individual elements. When combined with the reconstructed energy depositions in each element this allows for a calculation of the stopping power of track-like particles and opens the door to searches for particles with abnormal stopping power like monopoles or lightly-ionizing particles (LIPs). Results are presented which evaluate the precision of the reconstruction tools as they currently stand against Monte Carlo generated data. The algorithm is presented in the context of the CUORE experiment, but has applications to other segmented calorimeter detectors.

47 OTHER INSTRUMENTATION↗

Science and Technology of Future Light Sources

Many of the important challenges facing humanity, including developing alternative sources of energy and improving health, are being addressed by advances that demand the improved understanding and control of matter. While the visualization, exploration, and manipulation of macroscopic matter have long been technological goals, scientific developments in the twentieth century have focused attention on understanding matter on the atomic scale through the underlying framework of quantum mechanics. Of special interest is matter that consists of natural or artificial nanoscale building blocks defined either by atomic structural arrangements or by electron or spin formations created by collective correlation effects The essence of the challenge to the scientific community has been expressed in five grand challenges for directing matter and energy recently formulated by the Basic Energy Sciences Advisory Committee. These challenges focus on increasing our understanding of, and ultimately control of, matter at the level of atoms, electrons. and spins, as illustrated in Figure 1.1, and serve the entire range of science from advanced materials to life sciences. Meeting these challenges will require new tools that extend our reach into regions of higher spatial, temporal, and energy resolution. X-rays with energies above 10 keV offer capabilities extending beyond the nanoworld shown in Figure 1.1 due to their ability to penetrate into optically opaque or thick objects. This opens the door to combining atomic level information from scattering studies with 3D information on longer length scales from real space imaging with a resolution approaching 1 nm. The investigation of multiple length scales is important in hierarchical structures, providing knowledge about function of living organisms, the atomistic origin of materials failure, the optimization of industrial synthesis, or the working of devices. Since the fundamental interaction that holds matter together is of electromagnetic origin, it is intuitively clear that electromagnetic radiation is the critical tool in the study of material properties. On the level of atoms, electrons, and spins, x-rays have proved especially valuable. Future advanced x-ray sources and instrumentation will extend the power of x-ray methods to reach greater spatial resolution, increased sensitivity, and unexplored temporal domains. The purpose of this document is threefold: (1) summarize scientific opportunities that are beyond the reach of today's x-ray sources and instrumentation; (2) summarize the requirements for advanced x-ray sources and instrumentation needed to realize these scientific opportunities, as well as potential methods of achieving them; and (3) outline the R&D required to establish the technical feasibility of these advanced x-ray sources and instrumentation.

43 PARTICLE ACCELERATORS↗

Assessment of vertical stability for negative triangularity pilot plants

Abstract Negative triangularity (NT) tokamak configurations may be more susceptible to magneto-hydrodynamic instability, posing challenges for recent reactor designs centered around their favorable properties, such as improved confinement and operation free of edge-localized modes. In this work, we assess the vertical stability of plasmas with NT shaping and develop potential reactor solutions. When coupled with a conformal wall, NT equilibria are confirmed to be less vertically stable than equivalent positive triangularity (PT) configurations. Unlike PT, their vertical stability is degraded at higher poloidal beta. Furthermore, improvements in vertical stability at low aspect ratio do not translate to the NT geometry. NT equilibria are stabilized in PT vacuum vessels due to the increased proximity of the plasma and the wall on the outboard side, but this scenario is found to be undesirable due to reduced vertical gaps which give less spatial margin for control recovery. Instead, we demonstrate that informed positioning of passively conducting plates can lead to improved vertical stability in NT configurations on par with stability metrics expected in PT scenarios. An optimal setup for passive plates in highly elongated NT devices is presented, where plates on the outboard side of the device reduce vertical instability growth rates to 16% of their baseline value. For lower target elongations, integration of passive stabilizers with divertor concepts can lead to significant improvements in vertical stability. Plates on the inboard side of the device are also uniquely enabled in NT geometries, providing opportunity for spatial separation of vertical stability coils and passive stabilizers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing Sub-Sampled STEM Imaging for Beam Sensitive Materials and Dynamic Processes

The goal of this research is to quantify how sub-sampling and inpainting (broadly classified as methods in Artificial Intelligence) can be used to obtain the highest resolution images under any experimental conditions, and to use this to reproducibly control dynamic in-situ processes in gases and liquids on the nanoscale. As atomic diffusion under non-extreme conditions is typically in the sub-ms time domain, the ability to use this sub-sampling approach to reduce the effect of the electron beam and to speed-up the imaging process represents the optimum combination of spatial and temporal resolution achievable in a conventional microscope. This LDRD funding demonstrated the feasibility of imaging dynamics in complex energy systems using this methodology by establishing the optimum experimental sampling conditions (optimizing the number of pixels, speed, contrast and resolution) for each experiment. For in-situ liquid cell experiments this analysis shows that simply by distributing the same dose and dose rate maximally in space and time, the kinetics for radiolysis products can be modified significantly. The final stage of this work, i.e. the experimental demonstration of its use for nucleation and growth, was severely curtailed by issues with COVID19. However, all the experiments are designed and currently underway, with the goal to complete the final demonstration and publication as soon as safety concerns for laboratory access are met.

36 MATERIALS SCIENCE↗

MAGNETO-FRICTIONAL MODELING OF CORONAL NONLINEAR FORCE-FREE FIELDS. I. TESTING WITH ANALYTIC SOLUTIONS

We report our implementation of the magneto-frictional method in the Message Passing Interface Adaptive Mesh Refinement Versatile Advection Code (MPI-AMRVAC). The method aims at applications where local adaptive mesh refinement (AMR) is essential to make follow-up dynamical modeling affordable. We quantify its performance in both domain-decomposed uniform grids and block-adaptive AMR computations, using all frequently employed force-free, divergence-free, and other vector comparison metrics. As test cases, we revisit the semi-analytic solution of Low and Lou in both Cartesian and spherical geometries, along with the topologically challenging Titov–Démoulin model. We compare different combinations of spatial and temporal discretizations, and find that the fourth-order central difference with a local Lax–Friedrichs dissipation term in a single-step marching scheme is an optimal combination. The initial condition is provided by the potential field, which is the potential field source surface model in spherical geometry. Various boundary conditions are adopted, ranging from fully prescribed cases where all boundaries are assigned with the semi-analytic models, to solar-like cases where only the magnetic field at the bottom is known. Our results demonstrate that all the metrics compare favorably to previous works in both Cartesian and spherical coordinates. Cases with several AMR levels perform in accordance with their effective resolutions. The magneto-frictional method in MPI-AMRVAC allows us to model a region of interest with high spatial resolution and large field of view simultaneously, as required by observation-constrained extrapolations using vector data provided with modern instruments. The applications of the magneto-frictional method to observations are shown in an accompanying paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Applying simulation-based inference to spectral and spatial information from the Galactic Center gamma-ray excess

Abstract The two most favored explanations of theFermiGalactic Center gamma-ray excess (GCE) are millisecond pulsars and self annihilation of the smooth dark matter halo of the galaxy. In order to distinguish between these possibilities, we would like to optimally use all information in the available data, including photon direction and energy information.To date, analyses of the GCE have generally treated directional and energy information separately, or have ignored one or the other completely.Here, we develop a method for analyzing the GCE that relies on simulation-basedinference with neural posterior models to jointly analyze photon directional and spectral information while correctly accounting for the spatial and energy resolution of the telescope, here assumed to be theFermiLarge Area Telescope (LAT).Our results also have implications for analyses of the diffuse gamma-ray background, which we discuss.

Astronomy & Astrophysics↗

TH-CD-202-09: Free-Breathing Proton MRI Functional Lung Avoidance Maps to Guide Radiation Therapy

Purpose: Pulmonary functional MRI using inhaled gas contrast agents was previously investigated as a way to identify well-functioning lung in patients with NSCLC who are clinical candidates for radiotherapy. Hyperpolarized noble-gas ({sup 3}He and {sup 129}Xe) MRI has also been optimized to measure functional lung information, but for a number of reasons, the clinical translation of this approach to guide radiotherapy planning has been limited. As an alternative, free-breathing pulmonary 1H MRI using clinically available MRI systems and pulse sequences provides a non-contrast-enhanced method to generate both ventilation and perfusion maps. Free-breathing {sup 1}H MRI exploits non-rigid registration and Fourier decomposition of MRI signal intensity differences (Bauman et al., MRM, 2009) that may be generated during normal tidal breathing. Here, our objective was to generate free-breathing {sup 1}H MRI ventilation and lung function avoidance maps in patients with NSCLC as a way to guide radiation therapy planning. Methods: Stage IIIA/IIIB NSCLC patients (n=8, 68±9yr) provided written informed consent to a randomized controlled clinical trial ( https://clinicaltrials.gov/ct2/show/NCT02002052 ) that aimed to compare outcomes related to image-guided versus conventional radiation therapy planning. Hyperpolarized {sup 3}He/{sup 129}Xe and dynamic free tidal-breathing {sup 1}H MRI were acquired as previously described (Capaldi et al., Acad Radiol, 2015). Non-rigid registration was performed using the modality-independent-neighbourhood-descriptor (MIND) deformable approach (Heinrich et al., Med Image Anal, 2012). Ventilation-defect-percent ({sup 3}He:VDP{sub He}, {sup 129}Xe:VDP{sub Xe}, Free-breathing-{sup 1}H:VDP{sub FB}) and the corresponding ventilation maps were compared using Pearson correlation coefficients (r) and the Dice similarity coefficient (DSC). Results: VDP{sub FB} was significantly related to VDP{sub He} (r=.71; p=.04) and VDP{sub Xe} (r=.80; p=.01) and there were also strong spatial relationships (DSC{sub He}/DSC{sub Xe}=89±3%/77±11%). Conclusion: In this proof of concept study in NSCLC patients, free-breathing {sup 1}H MRI ventilation defects were quantitatively and spatially related to inhaled-noble-gas MRI ventilation defects. Free-breathing {sup 1}H MRI measures lung function/ventilation that can be used to optimize radiotherapy planning in NSCLC patients.

60 APPLIED LIFE SCIENCES↗

Implementing RapidArc into clinical routine: A comprehensive program from machine QA to TPS validation and patient QA

Purpose: With the increased commercial availability of intensity modulated arc therapy (IMAT) comes the need for comprehensive QA programs, covering the different aspects of this newly available technology. This manuscript proposes such a program for the RapidArc (RA) (Varian Medical Systems, Palo Alto) IMAT solution. Methods: The program was developed and tested out for a Millennium120 MLC on iX Clinacs and a HighDefinition MLC on a Novalis TX, using a variety of measurement equipment including Gafchromic film, 2D ion chamber arrays (Seven29 and StarCheck, PTW, Freiburg, Germany) with inclinometer and Octavius phantom, the Delta4 systam (ScandiDos, Uppsala, Sweden) and the portal imager (EPID). First, a number of complementary machine QA tests were developed to monitor the correct interplay between the accelerating/decelerating gantry, the variable dose rate and the MLC position, straining the delivery to the maximum allowed limits. Second, a systematic approach to the validation of the dose calculation for RA was adopted, starting with static gantry and RA specific static MLC shapes and gradually moving to dynamic gantry, dynamic MLC shapes. RA plans were then optimized on a series of artificial structures created within the homogeneous Octavius phantom and within a heterogeneous lung phantom. These served the double purpose of testing the behavior of the optimization algorithm (PRO) as well as the precision of the forward dose calculation. Finally, patient QA on a series of clinical cases was performed with different methods. In addition to the well established in-phantom QA, we evaluated the portal dosimetry solution within the Varian approach. Results: For routine machine QA, the ''Snooker Cue'' test on the EPID proved to be the most sensitive to overall problem detection. It is also the most practical one. The ''Twinkle'' and ''Sunrise'' tests were useful to obtain well differentiated information on the individual treatment delivery components. The AAA8.9 dose calculations showed excellent agreement with all corresponding measurements, except in areas where the 2.5 mm fixed fluence resolution was insufficient to accurately model the tongue and groove effect or the dose through nearly closed opposing leafs. Such cases benefited from the increased fluence resolution in AAA10.0. In the clinical RA fields, these effects were smeared out spatially and the impact of the fluence resolution was considerably less pronounced. The RA plans on the artificial structure sets demonstrated some interesting characteristics of the PRO8.9 optimizer, such as a sometimes unexpected dependence on the collimator rotation and a suboptimal coverage of targets within lung tissue. Although the portal dosimetry was successfully validated, we are reluctant to use it as a sole means of patient QA as long as no gantry angle information is embedded. Conclusions: The all-in validation program allows a systematic approach in monitoring the different levels of RA treatments. With the systematic approach comes a better understanding of both the capabilities and the limits of the used solution. The program can be useful for implementation, but also for the validation of major upgrades.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗