Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Towards 2+1 Flavor Lattice QCD Results for the Heavy Quark Diffusion Coefficient

We apply and extend a novel approach to non-perturbatively estimate the heavy-quark momentum diffusion coefficient κ, which is a key input for the theoretical description of heavy quarkonium production in heavy ion collisions, and is important for the understanding of the elliptic flow and nuclear suppression factor of heavy flavor hadrons. In the heavy-quark limit, this coefficient is encoded in the spectral functions of color-electric and color-magnetic correlators that we calculate on the lattice to high pre cision by applying gradient flow. In a recent study we have considered quenched QCD at 1.5 T c , where we performed a detailed study of the lat tice spacing and flow time dependence of the color-electric correlator, and, using theoretically well-established model fits for the spectral reconstruc tion, we estimated the heavy-quark diffusion coefficient. Equipped with the experience obtained in quenched QCD, we estimate $κ$ from 2+1 flavor QCD ensembles at small but finite lattice spacing and flow time without increasing systematic errors significantly.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A TiO2 abundance map for the northern maria

A map of TiO2 abundance for most of the northern maria is presented. The telescopic data base used is the 0.38/0.56-micron ratio mosaic from Johnson et at. (1977). The titanium content has been estimated using the correlation established by Charette et al. (1974). The combination of observational, processing, and calibration errors indicates that the TiO2 map is accurate to + or - 2% (wt% TiO2) for high TiO2 content (more than 5%) and + or - 1% for low values of TiO2. Analysis of the lunar sample and telescopic data suggests strongly that the spectral parameter mapped is sensitive primarily to TiO2 abundance in the range 3-9% and does not correlate directly with iron content. It is suggested, however, that for the low TiO2 mare regions (less than 2-3% TiO2) there may be a relation between the spectral ratio and iron content and that some of the reddest mare areas in the Imbrium region may have low iron contents as well as low titanium abundances.

Johnson, T. V.↗

The solar absolute spectral irradiance at 1216 A and 1800-3173 A - January 12, 1983

The full-disk solar spectral irradiance in the spectral range 1800-3173 A and at Lyman-alpha was obtained from a rocket observation above White Sands Missile Range, New Mexico, on January 12, 1983. Comparison with measurements made in May 1983 show no changes within the absolute errors of the experiment. The absolute calibration of the instruments for this flight was accomplished at the National Bureau of Standards Synchrotron Radiation Facility.

Mount, G. H.↗

A study of the dependence of Mg II emission on the rotational periods of main-sequence stars

International Ultraviolet Explorer satellite measurements of the Mg II chromospheric emission from a sample of late-type dwarfs with known rotational periods are presented. The ratio of chromospheric to photospheric luminosity for the late-G and K type stars in this sample can be fitted within the probable errors by a single function of rotational period. The chromospheric emission of early-G and F dwarfs appears to depend upon rotation in a qualitatively different way, which suggests that the rapid variation of convective zone properties in this spectral range affects the dissipation of energy in the chromosphere. Mg II h and k emission correlates fairly well with Ca II emission. However, the data sample is not large enough at present to show conclusively that Mg II emission exhibits precisely the same dependence on rotation and spectral type as the Ca II H and K line fluxes.

Hartmann, L.↗

A new solar irradiance calibration from 3295 A to 8500 A derived from absolute spectrophotometry of Vega

By imaging sunlight diffracted by 20- and 30-micron diameter pinholes onto the entrance aperture of a photoelectric grating scanner, the solar spectral irradiance was determined relative to the spectrophotometric standard star Vega, observed at night with the same instrument. Solar irradiances are tabulated at 4 A increments from 3295 A to 8500 A. Over most of the visible spectrum, the internal error of measurement is less than 2 percent. This calibration is compared with earlier irradiance measurements by Neckel and Labs (1984) and by Arvesen et al. (1969) and with the high-resolution solar atlas by Kurucz et al. The three calibrations agree well in visible light but differ by as much as 10 percent in the ultraviolet.

Lockwood, G. W.↗

Five years of Project META - An all-sky narrow-band radio search for extraterrestrial signals

We have conducted a five-year search of the northern sky (delta between 30 and 60 deg) for narrow-band radio signals near the 1420 MHz line of neutral hydrogen, and its second harmonic, using an 8.4 x 10 exp 6 channel Fourier spectrometer of 0.05 Hz resolution and 400 kHz instantaneous bandwidth. The observing frequency was corrected both for motions with respect to three astronomical inertial frames, and for the effect of Earth's rotation, which provides a characteristic changing Doppler signature for narrow-band signals of extraterrestrial origin. Among the 6 x 10 exp 13 spectral channels searched, we have found 37 candidate events exceeding the average detection threshold of 1.7 x 10 exp -23 W/sq m, none of which was detected upon reobservation. The strongest of these appear to be dominated by rare processor errors. However, the strongest signals that survive culling for terrestrial interference lie in or near the Galactic plane. We describe the search and candidate events, and set limits on the prevalence of supercivilizations transmitting Doppler-precompensated beacons at H I or its second harmonic. We conclude with recommendations for future searches, based upon these findings, and a description of our next-generation search system.

Horowitz, Paul↗

The 1991 AVIRIS/POLDER experiment in Camargue, France

Airborne campaigns during the eighties provided high spectral resolution data, collected with imaging instruments such as AIS, AVIRIS, FLI, CAESI, and ISM, in order to investigate the relationship with canopy biophysical characteristics. The statistical approaches used to analyze these data do not allow investigation of the causality and the applicability of the observed correlations. Further, statistical studies demonstrated the high degree of redundancy of the spectral information amongst many others. And for retrieving vegetation biophysical characteristics, few results demonstrate the real information gain attributable to the high spectral resolution capability as compared to the use of a few wide wavelength bands. With several new imaging spectrophotometers scheduled for launch during the next 10 years (MERIS, MODIS, HIRIS), progress in the description and understanding of the mechanisms that drive the spectral variation of canopy reflectance is required. Most of these new sensor systems will also have the capability to observe the target under differing view directions. The problem of the combination and the use of the synergy between both the spectral and the directional sources of canopy reflectance variations has to be addressed. Apart from the atmospheric effects, the spectral variation of the light reflected by canopies originates from the leaves, the soil or the other vegetation elements such as branches and fruits. At leaf level, both diffuse reflectance and transmittance may be simulated by simple models, although no accurate information exists on the absorption features of the biochemicals (except water) in the 900-2500nm wavelength range. Many models mimic the directional variability of canopy reflectance at a given wavelength. Combining a leaf spectral model with a canopy directional model provides a powerful tool to analyze this problem. Some of us have initiated such a study, but our approach and theory remain to be tested using canopy data with their complexity, associated experimental error, and atmospheric effects. The main objective of the 1990 POLDER/AVIRIS experiment in Camargue was to provide a consistent data set over various canopies in order to test the applicability of the theory. The experiment, part of the 1991 MAC Europe experiment, involved simultaneous data collection using two sensors: AVIRIS and POLDER which measures the bidirectional and polarization properties of the targets at 670 and 880nm wavebands.

Baret, F.↗

Sensitivity of the Tropical Atmospheric Energy Balance to ENSO-Related SST Changes: Comparison of Climate Model Simulations to Observed Responses

This paper focuses on how fresh water and radiative fluxes over the tropical oceans change during ENSO warm and cold events and how these changes affect the tropical energy balance. At present, ENSO remains the most prominent known mode of natural variability at interannual time scales. While this natural perturbation to climate is quite distinct from possible anthropogenic changes in climate, adjustments in the tropical water and energy budgets during ENSO may give insight into feedback processes involving water vapor and cloud feedbacks. Although great advances have been made in understanding this phenomenon and realizing prediction skill over the past decade, our ability to document the coupled water and energy changes observationally and to represent them in climate models seems far from settled (Soden, 2000 J Climate). In a companion paper we have presented observational analyses, based principally on space-based measurements which document systematic changes in rainfall, evaporation, and surface and top-of-atmosphere (TOA) radiative fluxes. Here we analyze several contemporary climate models run with observed SSTs over recent decades and compare SST-induced changes in radiation, precipitation, evaporation, and energy transport to observational results. Among these are the NASA / NCAR Finite Volume Model, the NCAR Community Climate Model, the NCEP Global Spectral Model, and the NASA NSIPP Model. Key disagreements between model and observational results noted in the recent literature are shown to be due predominantly to observational shortcomings. A reexamination of the Langley 8-Year Surface Radiation Budget data reveals errors in the SST surface longwave emission due to biased SSTs. Subsequent correction allows use of this data set along with ERBE TOA fluxes to infer net atmospheric radiative heating. Further analysis of recent rainfall algorithms provides new estimates for precipitation variability in line with interannual evaporation changes inferred from the da Silva, Young, Levitus COADS analysis. The overall results from our analysis suggest an increase (decrease) of the hydrologic cycle during ENSO warm (cold) events at the rate of about 5 W/sq m per K of SST change. Model results agree reasonably well with this estimate of sensitivity. This rate is slightly less than that which would be expected for constant relative humidity over the tropical oceans. There remain, however, significant quantitative uncertainties in cloud forcing changes in the models as compared to observations. These differences are examined in relationship to model convection and cloud parameterizations Analysis of the possible sampling and measurement errors compared to systematic model errors is also presented.

Robertson, Franklin R.↗

A Note on the Temporary Misregistration of Landsat-8 Operational Land Imager (OLI) and Sentinel-2 Multi Spectral Instrument (MSI) Imagery

The Landsat-8 and Sentinel-2 sensors provide multi-spectral image data with similar spectral and spatial characteristics that together provide improved temporal coverage globally. Both systems are designed to register Level 1 products to a reference image framework, however, the Landsat-8 framework, based upon the Global Land Survey images, contains residual geolocation errors leading to an expected sensor-to-sensor misregistration of 38 m (2sigma). These misalignments vary geographically but should be stable for a given area. The Landsat framework will be readjusted for consistency with the Sentinel-2 Global Reference Image, with completion expected in 2018. In the interim, users can measure Landsat-to-Sentinel tie points to quantify the misalignment in their area of interest and if appropriate to reproject the data to better alignment.

Storey, James↗

Noise Reduction for Solar-Induced Fluorescence Retrievals Using Machine Learning and Principal Component Analysis: Simulations and Applications to GOME-2 Satellite Retrievals

We use a spectral-based approach that employs principal component analysis along with a relatively shallow artificial neural network (NN) to substantially reduce noise and other artifacts in terrestrial chlorophyll solar-induced fluorescence (SIF) retrievals. SIF is a very small emission at red and far-red wavelengths that is difficult to measure and is highly sensitive to random errors and systematic artifacts. Our approach relies upon an assumption that a trained NN can effectively reconstruct the total SIF signal from a relatively small number of leading principal components of the satellite-observed far-red radiance spectra without using information from the trailing modes that contain most of the random errors. We test the approach with simulated reflectance spectra produced with a full atmospheric and surface radiative transfer model using different observing and geophysical parameters and various noise levels. Resulting noisy and noise-reduced retrieved SIF values are compared with true values to assess performance. We then apply our noise reduction approach to SIF derived from two different satellite spectrometers. For evaluation, since the truth in this case is unknown, we compare SIF retrievals from two independent sensors with each other. We also compare the noise-reduced SIF temporal variations with those from an independent gross primary product (GPP) product that should display similar variations. Results show that our noise reduction approach improves capture of SIF seasonal and inter-annual variability. Our approach should be applicable to many noisy data products derived from spectral measurements. Our methodology does not replace the original retrieval algorithms; rather the original noisy retrievals are needed as the target for the NN training process.

noise reduction, solar-induced fluorescence, SIF, ↗

Hyperspectral imaging for real-time waste materials characterization and recovery using endmember extraction and abundance detection

Hyperspectral imaging, combined with advanced spectral unmixing techniques and artificial intelligence, offers a powerful solution for improving material identification and classification. Here, this study evaluates the effectiveness of the pixel purity index and the sequential maximum angle convex cone algorithms in extracting and validating spectral signatures from pure samples of paper components (cellulose and lignin) and plastic (polypropylene). Principal-component analysis showed that both algorithms captured nearly all relevant variance for the tested materials. Spectral signatures were compared using the spectral angle mapper, revealing high similarity in the short-wave infrared region and greater variability in the visible near-infrared range. The methodology was then applied to a disposable coffee cup to detect and quantify mixed materials, accurately estimating material abundance and object area with less than 1% error. This approach enhances material classification, supporting product verification, quality control, and automated sorting for sustainable waste management and resource recovery.

36 MATERIALS SCIENCE↗

Solar Cell Short Circuit Current Errors and Uncertainties During High Altitude Calibrations

High altitude balloon based facilities can make solar cell calibration measurements above 99.5% of the atmosphere to use for adjusting laboratory solar simulators. While close to on-orbit illumination, the small attenuation to the spectra may result in under measurements of solar cell parameters. Variations of stratospheric weather, may produce flight-to-flight measurement variations. To support the NSCAP effort, this work quantifies some of the effects on solar cell short circuit current (Isc) measurements on triple junction sub-cells. This work looks at several types of high altitude methods, direct high altitude meas urements near 120 kft, and lower stratospheric Langley plots from aircraft. It also looks at Langley extrapolation from altitudes above most of the ozone, for potential small balloon payloads. A convolution of the sub-cell spectral response with the standard solar spectrum modified by several absorption processes is used to determine the relative change from AMO, lscllsc(AMO). Rayleigh scattering, molecular scatterin g from uniformly mixed gases, Ozone, and water vapor, are included in this analysis. A range of atmosph eric pressures are examined, from 0. 05 to 0.25 Atm to cover the range of atmospheric altitudes where solar cell calibrations a reperformed. Generally these errors and uncertainties are less than 0.2%

Snyder, David D.↗

Advanced Mass Calibration and Visualization for FT-ICR Mass Spectrometry Imaging

Mass spectrometry imaging by Fourier transform ion cyclotron resonance (FT-ICR) yields hundreds of unique peaks, many of which cannot be resolved by lower performance mass spectrometers. The high mass accuracy and high mass resolving power allow confident identification of small molecules and lipids directly from biological tissue sections. Here, calibration strategies for FT-ICR MS imaging were investigated. Sub-parts-per-million mass accuracy is demonstrated over an entire tissue section. Ion abundance fluctuations are corrected by addition of total and relative ion abundances for a root-mean-square error of 0.158 ppm on 16,764 peaks. A new approach for visualization of FT-ICR MS imaging data at high resolution is presented. The "Mosaic Datacube" provides a flexible means to visualize the entire mass range at a mass spectral bin width of 0.001 Da. The high resolution Mosaic Datacube resolves spectral features not visible at lower bin widths, while retaining the high mass accuracy from the calibration methods discussed.

Environmental Molecular Sciences Laboratory↗

Development of a nine spatial point, multipulse Thomson scattering diagnostic

A Thomson scattering diagnostic has been developed for the C-2 field-reversed configuration device. Based on a multipulse ruby laser, the system measures the electron temperature at nine spatial points. These points are chosen from 22 selectable positions covering r{approx_equal}1-41 cm. Twin collection lenses couple the scattered photons to nine optical fiber pairs. Extra fiber lengths delay the signals from different spatial points relative to each other, allowing up to three points to be analyzed by a single polychromator. The polychromator, using compact photomultipliers as detectors, has six spectral channels covering the range of 685-725 nm and is able to estimate electron temperatures of {approx_equal}10-200 eV. The photomultiplier output signals are recorded by digital storage oscilloscopes integrated with the main MDSplus database, with temperature and error estimates generated automatically at the conclusion of each plasma discharge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mathematical simulation of an experimental prototype of a high-speed nonreturn-to-zero differential phase-shift-keying fibre-optic communication system

The influence of chromatic dispersion, optical power, and nonlinear distortions in a fibre-optic communication system on the quality of data transmission based on nonreturn-to-zero differential phase-shift keying at a rate of 40 Gbit s{sup -1} in one spectral channel have been numerically simulated and experimental studied. The results of direct numerical calculations and estimates based on the quality factor (Q factor) are in qualitative agreement with the experimental data. It is found experimentally that the dependence of the error rate on the accumulated dispersion has a plateau in the range from -50 to 50 ps nm{sup -1}; a similar dependence is obtained in the numerical calculation based on the Q factor. The optimal calculated value of the power launched into each of 10 sections of a line with a total length of 1000 km is 2 - 4 dBm; it corresponds to the experimental value of 3 dBm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Role of Presented Objects in Deriving Color Preference Criteria from Psychophysical Studies

Of the many “components” of a color rendering measure, one is perhaps the most important: the set of color samples (spectral reflectance functions) that are employed as a standardized means of evaluating and rating a light source. At the same time, a standardized set of color samples can never apply perfectly to a real space or a real set of observed objects, meaning there will always be some level of mismatch between the predicted and observed color shifts. This mismatch is important for lighting specifiers to consider, but even more critical for experiments that seek to evaluate the relationship between color rendering measures and human perception. This article explores how the color distortions of three possible experimental object sets compare to the color distortions predicted using the color evaluation samples of IES TM-30-15 (TM-30). The experimental object sets include those from Royer and colleagues [2016], a set of produce (10 fruits and vegetables), and the X-rite Color Checker Classic. The differences are traced back to properties of the samples sets, such as the coverage of color space, average chroma level, and specific spectral features. The consequence of the differences, that the visual evaluation is based on color distortions that are substantially different from what is predicted, can lead to inaccurate criteria or models of a given perception, such as preference. To minimize the error in using criteria or models when specifying color rendering attributes for a given application, the criteria or models should be developed using a set of experimental objects that matches the typical objects of the application as closely as possible. Alternatively, if typical objects of an application cannot be reasonably determined, an object set that matches the distortions predicted by TM-30 as close as possible is likely to provide the most meaningful results.

60 APPLIED LIFE SCIENCES↗

SU-D-207A-01: Female Pelvic Synthetic CT Generation Based On Joint Shape and Intensity Analysis

Purpose: To develop a method for generating female pelvic synthetic CT (MRCT) images from a single MR scan and evaluate its utility in radiotherapy. Methods: Under IRB-approval, an imaging sequence (T1-VIBE-Dixon) was acquired for 10 patients. This sequence yields 3 useful image volumes of different contrast (“in-phase” T1-weighted, fat and water). A previously published pelvic bone shape model was used to generate a rough bone mask for each patient. A modified fuzzy c-means classification was performed on the multi spectral MR data, with a regularization term that utilizes the prior knowledge provided by the bone mask and addresses the intensity overlap between different tissue types. A weighted sum of classification probabilities with attenuation values yielded MRCT volumes. The mean absolute error (MAE) between MRCT and real CT on various regions was calculated following deformable alignment (Velocity). Intensity modulated Treatment plans based on actual CT and MRCT were made and compared. Results: The average/standard deviation of MAE across 10 patients was 10.1/6.7 HU for muscle, 6.7/4.6 HU for fat, 136.9/53.5 HU for bony tissues under 850 HU (97% of total bone volume), 188.9/119.3 HU for bony tissues above 850 HU and 17.3/13.3 HU for intrapelvic soft tissues. Calculated doses were comparable for plans generated on CT and calculated using MRCT densities or vice versa, with differences in PTV D99% (mean/σ) of (–0.1/0.2 Gy) and (0.3/0.2 Gy), PTV D0.5cc of (–0.3/0.2 Gy) and (–0.4/1.7 Gy). OAR differences were similarly small for comparable structures, with differences in bowel V50Gy of (–0.3/0.2%) and (0.0/0.2%), femur V30Gy of (0.7/1.2%) and (0.2/1.2%), sacrum V20GY of (0.0/0.1%) and (–0.1/1.1%) and mean pelvic V20Gy of (0.0/0.1%) and (0.6/1.8%). Conclusion: MRCT based on a single imaging sequence in the female pelvis is feasible, with acceptably small variations in attenuation estimates and calculated doses to target and critical organs. Work supported by NIHR01EB016079.

60 APPLIED LIFE SCIENCES↗

Filters for Improvement of Multiscale Data from Atomistic Simulations

Multiscale computational models strive to produce accurate and efficient numerical simulations of systems involving interactions across multiple spatial and temporal scales that typically differ by several orders of magnitude. Some such models utilize a hybrid continuum-atomistic approach combining continuum approximations with first-principles-based atomistic models to capture multiscale behavior. By following the heterogeneous multiscale method framework for developing multiscale computational models, unknown continuum scale data can be computed from an atomistic model. Concurrently coupling the two models requires performing numerous atomistic simulations which can dominate the computational cost of the method. Furthermore, when the resulting continuum data is noisy due to sampling error, stochasticity in the model, or randomness in the initial conditions, filtering can result in significant accuracy gains in the computed multiscale data without increasing the size or duration of the atomistic simulations. In this work, we demonstrate the effectiveness of spectral filtering for increasing the accuracy of noisy multiscale data obtained from atomistic simulations. Moreover, we present a robust and automatic method for closely approximating the optimum level of filtering in the case of additive white noise. By improving the accuracy of this filtered simulation data, it leads to a dramatic computational savings by allowing for shorter and smaller atomistic simulations to achieve the same desired multiscale simulation precision.

97 MATHEMATICS AND COMPUTING↗