Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

The HYDROS Radiometer/Radar Instrument

The science objectives of the HYDROS mission are to provide frequent, global measurements of surface soil moisture and surface freeze/thaw state. In order to adequately measure these geophysical quantities, the key instrument requirements were determined by the HYDROS science team to be: 1) Dual-polarization L-Band passive radiometer measurements at 40 km resolution, 2) Dual-polarization L-Band active radar measurements at 3 km resolution, and 3) A wide swath to insure global three day refresh time for these measurements (1000 km swath at the selected orbit altitude of 670 km). As a solution to this challenging set of instrument requirements, a relatively large, 6 meter, conically-scanning reflector antenna architecture was selected for the instrument design. The deployable mesh antenna is shared by both the radiometer and radar electronics by employing a single L-Band feed.

freeze thaw↗

The Hayabusa2 Sample Return Mission and Its Small Carry-On Impactor Experiment

On December 3, 2014 the Hayabusa2 Spacecraft was launched by JAXA to investigate and return samples from carbonaceous Asteroid (162173) Ryugu. The spacecraft's payload contains several remote sensing instruments that are designed to characterize the asteroid's surface and to help identify scientifically interesting locations from which samples can be obtained safely. The data collected by these instruments will also help place any obtained samples in context with respect to the global characteristics of Ryugu. In addition to the suite of remote sensing instruments and the sampling device, Hayabusa2 also includes a small carry-on impactor (SCI) payload experiment, which is designed to impact the surface of the asteroid and excavate fresh material for subsequent collection. The SCI consists of a 30 cm diameter 2 kg copper disk that is accelerated by an explosive charge into the surface of Ryugu at approximately 2 km/s. The resultant crater formed during this experiment is estimated to be approximately between 2 - 10 meters in diameter with an ejecta blanket extending to 10 - 100 meters on the asteroid. Hayabusa2 will not be able to observe the impact experiment directly due to considerations of spacecraft safety since there is some risk of collisions with debris from the explosion and ejecta from the crater. However, prior to moving safely away, the spacecraft will deploy a small imaging system called Deployable Camera 3 (DCAM3). DCAM3 will detach from Hayabusa2 just before the detonation of the SCI and will image the moment of impact, crater formation, and ejecta propagation. These data will be transmitted to Hayabusa2 and will help constrain the near-surface properties of Ryugu and also impact scaling laws for small bodies in low gravity environments. These data could also be useful for gaining insights into determining asteroid physical properties from higher velocity impact events (e.g., DART and HERA data of Didymos).

Abell, Paul A.↗

Mariner-mars absorptance experiment.

Absorptivity standard instrument to investigate solar absorptance of four surfaces used for spacecraft temperature control for Mariner IV on Mars mission

ABSORPTIVE INDEX↗

Miniaturized Hollow-Waveguide Gas Correlation Radiometer (GCR) for Trace Gas Detection in the Martian Atmosphere

Gas correlation radiometry (GCR) has been shown to be a sensitive and versatile method for detecting trace gases in Earth's atmosphere. Here, we present a miniaturized and simplified version of this instrument capable of mapping multiple trace gases and identifying active regions on the Mars surface. Reduction of the size and mass of the GCR instrument has been achieved by implementing a lightweight, 1 mm inner diameter hollow-core optical fiber (hollow waveguide) for the gas correlation cell. Based on a comparison with an Earth orbiting CO2 gas correlation instrument, replacement of the 10 meter mUltipass cell with hollow waveguide of equivalent pathlength reduces the cell mass from approx 150 kg to approx 0.5 kg, and reduces the volume from 1.9 m x 1.3 m x 0.86 m to a small bundle of fiber coils approximately I meter in diameter by 0.05 m in height (mass and volume reductions of >99%). This modular instrument technique can be expanded to include measurements of additional species of interest including nitrous oxide (N2O), hydrogen sulfide (H2S), methanol (CH3OH), and sulfur dioxide (SO2), as well as carbon dioxide (CO2) for a simultaneous measure of mass balance.

Wilson, Emily L.↗

Surface Deformation and Coherence Measurements of Kilauea Volcano, Hawaii, from SIR-C Radar Interferometry

The shuttle imaging radar C/X synthetic aperture radar (SIR-C/X-SAR) radar on board the space shuttle Endeavor imaged Kilauea Volcano, Hawaii, in April and October 1994 for the purpose of measuring active surface deformation by the methods of repeat-pass differential radar interferometry. Observations at 24 cm (L band) and 5.6 cm (C band) wavelengths were reduced to interferograms showing apparent surface deformation over the 6-month interval and over a succession of 1-day intervals in October. A statistically significant local phase signature in the 6-month interferogram is coincident with the Pu'u O'o lava vent. Interpreted as deformation, the signal implies centimeter-scale deflation in an area several kilometers wide surrounding the vent. Peak deflation is roughly 14 cm if the deformation is purely vertical, centered southward of the Pu'u O'o caldera. Delays in the radar signal phase induced by atmospheric refractivity anomalies introduce spurious apparent deformation signatures, at the level of 12 cm peak-to-peak in the radar line-of-sight direction. Though the phase observations are suggestive of the wide-area deformation measured by Global Positioning System (GPS) methods, the atmospheric effects are large enough to limit the interpretation of the result. It is difficult to characterize centimeter-scale deformations spatially distributed over tens of kilometers using differential interferometry without supporting simultaneous, spatially distributed measurements of reactivity along the radar line of sight. Studies of the interferometric correlation of images acquired at different times show that L band is far superior to C band in the vegetated areas, even when the observations are separated by only 1 day. These results imply longer wavelength instruments are more appropriate for studying surfaces by repeat-pass observations.

Rosen, P. A.↗

Albedo Data for Bifacial PV Systems

At the September 2018 Bifacial PV Workshop in Lakewood, CO, a better understanding of albedo values and characteristics was identified as a key need by both the PV and financial communities to better estimate performance and to reduce risk of bifacial PV systems. To meet this need, the U.S. Department of Energy (DOE) has initiated work with the National Renewable Energy Laboratory (NREL) to provide the following: A multi-year database of measured and quality assessed albedo values with temporal resolution of one hour or less for numerous locations and types of ground surfaces. Site metadata for each location (Pictures, instruments and calibration history, soil and vegetation types, etc.) Site albedo statistics for each location (diurnal profiles, monthly and annual means, interannual variability) Analysis of the spectral mismatch for bifacial PV modules of the ground-reflected radiation for anticipated deployment surfaces (using both measured and modeled spectral albedo data). Comparisons of the measured albedos with available satellite-derived MODIS albedo products to validate the MODIS albedo products for estimating bifacial PV system performance.

14 SOLAR ENERGY↗

On the induction of homogeneous bulk crystallization in Eu-doped calcium aluminosilicate glass by applying simultaneous high pressure and temperature

From initial calcium aluminosilicate glass, transparent glass-ceramics have been successfully synthesized under simultaneous high pressure and temperature (SHPT). Possible homogeneous volumetric crystallization of this glassy system, which was not achieved previously by means of conventional heat treatment, has been put in evidence with a SHPT procedure. Structural, mechanical, and optical properties of glass and glass-ceramic obtained were investigated. Raman spectroscopy and X-ray diffraction allowed to identify two main crystalline phases: merwinite [Ca{sub 3}Mg(SiO{sub 4}){sub 2}] and diopside [CaMgSi{sub 2}O{sub 6}]. A Raman scanning profile showed that the formation of merwinite is quite homogeneous over the bulk sample. However, the sample surface also contains significant diopside crystals. Instrumented Berkovich nanoindentation was applied to determine the effect of SHPT on hardness from glass to glass-ceramic. For Eu-doped samples, the broadband emission due to 4f{sup 6}5d{sup 1} → 4f{sup 7} transition of Eu{sup 2+} was studied in both host systems. Additionally, the {sup 5}D{sub 0} → {sup 7}F{sub J} transition of Eu{sup 3+} was used as an environment probe in the pristine glass and the glass-ceramic.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MapX: 2D XRF for Planetary Exploration - Image Formation and Optic Characterization

Map-X is a planetary instrument concept for 2D X-Ray Fluorescence (XRF) spectroscopy. The instrument is placed directly on the surface of an object and held in a fixed position during the measurement. The formation of XRF images on the CCD detector relies on a multichannel optic configured for 1:1 imaging and can be analyzed through the point spread function (PSF) of the optic. The PSF can be directly measured using a micron-sized monochromatic X-ray source in place of the sample. Such PSF measurements were carried out at the Stanford Synchrotron and are compared with ray tracing simulations. It is shown that artifacts are introduced by the periodicity of the PSF at the channel scale and the proximity of the CCD pixel size and the optic channel size. A strategy of sub-channel random moves was used to cancel out these artifacts and provide a clean experimental PSF directly usable for XRF image deconvolution.

47 OTHER INSTRUMENTATION↗

Experimental Study of a Membrane Antenna Surface Adaptive Control System

Due to their ultra lightweight and high packaging efficiency, membrane reflectors are getting more and more attentions for mission architectures that need extremely large inspace deployable antennas. However how to maintain the surface shape of a membrane reflector to the instrument precision requirements is a very challenging problem. This experimental study investigated using PVDF membrane piezoelectric material as actuators to control the surface figures of membrane reflectors. The feasibility of this approach is demonstrated by several sets of test results.

packaging↗

Dry calibration of electromagnetic flowmeters based on numerical models combining multiple physical phenomena (multiphysics)

This paper presents a method for dry calibration of an electromagnetic flowmeter (EMF). This method, which determines the voltage induced in the EMF as conductive liquid flows through a magnetic field, numerically solves a coupled set of multiphysical equations with measured boundary conditions for the magnetic, electric, and flow fields in the measuring pipe of the flowmeter. Specifically, this paper details the formulation of dry calibration and an efficient algorithm (that adaptively minimizes the number of measurements and requires only the normal component of the magnetic flux density as boundary conditions on the pipe surface to reconstruct the magnetic field involved) for computing the sensitivity of EMF. Along with an in-depth discussion on factors that could significantly affect the final precision of a dry calibrated EMF, the effects of flow disturbance on measuring errors have been experimentally studied by installing a baffle at the inflow port of the EMF. Results of the dry calibration on an actual EMF were compared against flow-rig calibration; excellent agreements (within 0.3%) between dry calibration and flow-rig tests verify the multiphysical computation of the fields and the robustness of the method. As requiring no actual flow, the dry calibration is particularly useful for calibrating large-diameter EMFs where conventional flow-rig methods are often costly and difficult to implement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pushbroom radiometry and its potential using large space antennas

Electromagnetic radiation is emitted by matter which was heated to a temperature above absolute zero. The amount of blackbody radiation in the microwave frequency region of interest (10 to the 8th power f 10 to the 10th power Hz) emitted by matter can be determined from the Rayleigh-Jeans approximation to Planck's Radiation Law. The amount of electromagnetic radiation from matter which is not a blackbody is a function of the emissivity of the material. The emissivity is a factor less than unity and is a function of several parameters including chemical composition, temperature, frequency, surface characteristics, and viewing angle. A radiometer is an instrument which detects and provides a measure of the electromagnetic radiation being emitted by a material or surface area within the radiometer's antenna beamwidth. Microwave radiometers provide the capability for remote measurements from Earth orbits of geophysical parameters. These measurements will require the use of a microwave imaging radiometer using a large aperture deployable antenna with multiple beams in a pushbroom mode to achieve high spatial resolution and large swath width.

Harrington, R. F.↗

Sensor requirements for Earth and planetary observations

Future generations of Earth and planetary remote sensing instruments will require extensive developments of new long-wave and very long-wave infrared detectors. The upcoming NASA Earth Observing System (EOS) will carry a suite of instruments to monitor a wide range of atmospheric and surface parameters with an unprecedented degree of accuracy for a period of 10 to 15 years. These instruments will observe Earth over a wide spectral range extending from the visible to nearly 17 micrometers with a moderate to high spectral and spacial resolution. In addition to expected improvements in communication bandwidth and both ground and on-board computing power, these new sensor systems will need large two-dimensional detector arrays. Such arrays exist for visible wavelengths and, to a lesser extent, for short wavelength infrared systems. The most dramatic need is for new Long Wavelength Infrared (LWIR) and Very Long Wavelength Infrared (VLWIR) detector technologies that are compatible with area array readout devices and can operate in the temperature range supported by long life, low power refrigerators. A scientific need for radiometric and calibration accuracies approaching 1 percent translates into a requirement for detectors with excellent linearity, stability and insensitivity to operating conditions and space radiation. Current examples of the kind of scientific missions these new thermal IR detectors would enhance in the future include instruments for Earth science such as Orbital Volcanological Observations (OVO), Atmospheric Infrared Sounder (AIRS), Moderate Resolution Imaging Spectrometer (MODIS), and Spectroscopy in the Atmosphere using Far Infrared Emission (SAFIRE). Planetary exploration missions such as Cassini also provide examples of instrument concepts that could be enhanced by new IR detector technologies.

Chahine, Moustafa T.↗

Seeking to Improve Low Energy Neutral Atom Detection in Space

The detection of energetic neutral atoms allows for the remote examination of the interactions between plasmas and neutral populations in space. Before these neutral atoms can be measured, they must first be converted to ions. For the low energy end of this spectrum, interaction with a conversion surface is often the most efficient method to convert neutrals into ions. It is generally thought that the most efficient surfaces are low work functions materials. However, by their very nature, these surfaces are highly reactive and unstable, and therefore are not suitable for space missions where conditions cannot be controlled as they are in a laboratory. We therefore are looking to optimize a stable surface for conversion efficiency. Conversion efficiency can be increased either by changing the incident angle of the neutral particles to be grazing incidence and using stable surfaces with high conversion efficiencies. We have examined how to increase the angle of incidence from -80 degrees to -89 degrees, while maintaining or improving the total active conversion surface area without increasing the overall volume of the instrument. We are developing a method to micro-machine silicon, which will reduce the volume to surface area ratio by a factor of 60. We have also examined the material properties that affect the conversion efficiency of the surface for stable surfaces. Some of the parameters we have examined are work function, smoothness, and bond structure. We find that for stable surfaces, the most important property is the smoothness of the surface.

Shappirio, M.↗

Imaging spectrometry: Past, present, future

Imaging spectrometry for the remote sensing of the Earth from aircraft and satellites is discussed. Results with an aircraft instrument show that remote, direct identification of surface materials is possible. The airborne and spaceborne sensors can acquire images in 100 to 200 spectral bands. The next generation aircraft scanner (AVIRIS) is expected to be operational in 1987. Plans are underway for a Shuttle instrument (SISEX) to fly in 1991.

Abrams, M. J.↗

Martian aerosols: Near-infrared spectral properties and effects on the observation of the surface

Imaging sprectroscopic measurements (ISM) of Mars acquired by the ISM instrument on Phobos-2 are used to investigate the NIR spectral properties of aerosols and the effects of atmospheric scattering on inferred mineralogy of the surface. Estimates of aerosols spectra between 0.77 and 2.6 micrometers are derived above Tharsis and Ophir Planum. The spectral continua are consistent with the particle size distribution derived using data from the solar occultation experiment on-board the spacecraft (effective radius approximately = 1.2 micrometers, with an effective variance approximately = 0.2). The aerosols spectra contain water-ice absorption features and possibly absorptions due to clay and/or sulfates. The largest effect of the aerosols on surface spectra is in dark regions, where the continuum spectral slope becomes more negative and the 1-micrometers absorption due to Fe in pyroxene is shifted toward longer wavelengths. The effects of aerosols on spectra of bright regions are insufficiently large to change mineralogic interpretations based on ISM data, i.e., that bright regions in Tharsis are dominated spectrally by hematite, but that additional ferric minerals are probably present in other areas including Arabia.

Erard, Stephane↗

Global Auroral Imaging for the Dynamics Explorer Mission

The two Dynamics Explorer spacecraft, DE-1 and DE-2, were launched on August 3, 1981, into polar coplanar orbits at different altitudes for the purpose of studying interactive processes within the atmosphere-ionosphere-magnetosphere system. The DE-1 spacecraft (high-altitude mission) used an elliptical orbit that was selected to allow: (1) measurements extending from the hot magnetospheric plasma through the plasmasphere to the cool ionosphere; (2) global auroral imaging, wave measurements in the heart of the magnetosphere, and crossing of auroral field lines at several earth radii; and (3) measurements for significant periods of time along a magnetic field flux tube. The orbit of Dynamics Explorer 1 offered an opportunity to obtain global images of Earth's dayglow and auroral luminosities and to acquire consecutive images of the entire auroral oval during the growth, onset, expansion, and recovery phases of substorms. The University of Iowa's Spin-scan Auroral Imaging (SAI) instrument, was on-board DE-1. SAI was activated in orbit and placed in routine operation on September 23, 1981, and has provided outstanding new contributions in the fields of auroral, magnetospheric and geocoronal physics, introduced a powerful tool for the study of global atmospheric ozone, and initiated the first search from space for marine bioluminescence on the surface of the global ocean. The SAI instrumentation consists of three imaging photometers, two for visible wavelengths and the third for vacuum-ultraviolet wavelengths equipped with primary catoptric optics with superpolished mirror surfaces. The primary focusing element is an off-axis section of a parabolic mirror that is used to provide an optical path completely free of support structures for the mirrors.

Frank, L. A.↗

In-situ monitoring of flow-permeable surface area of high explosive powder using small sample masses

To ensure good performance of high explosive devices over long periods of time, initiating powders need to maintain their specific surface area within allowed margins during the entire duration of deployment. A common diagnostic used in this context is the Fisher sub-sieve surface area (FSSA). Furthermore, commercial permeametry instruments measuring the FSSA requires the utilization of a sample mass equal to the crystal density of the sample material, an amount that is often one or two orders of magnitude larger than the typical masses found in standard detonator applications. Here we develop a customization of the standard device that can utilize just tens of milligram samples, and with simple calibration yield FSSA values at ac curacy levels comparable to the standard apparatus. This necessitated a newly designed sample holder, made from a material of low coefficient of thermal expansion, which is conveniently transferred between an aging chamber and a re-designed permeametry tube. This improves the fidelity of accelerated aging studies by allowing measurement on the same physical sample at various time - instants during the aging process, and by obviating the need for a potentially FSSA-altering powder re-compaction step. We used the customized apparatus to monitor the FSSA evolution of a number of undoped and homolog-doped PETN powder samples that were subjected to artificial aging for several months at elevated temperatures. These results, in conjunction with an Arrhenius-based aging model were used to assess powder-coarsening - rates under long-term storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mars Entry Instrumentation Flight Data and Mars 2020 Entry Environments

On February 18th, 2021, the Mars 2020 entry vehicle delivered the Perseverance rover to the surface of Mars. The entry vehicle carried a set of instrumentation installed on the heatshield and backshell to measure aerodynamic and aerothermal performance, named the Mars Entry, Descent, and Landing Instrumentation 2. This set of instrumentation included pressure transducers, thermocouples, heatflux sensors, and a radiometer, as well as a dedicated sensor support electronics system. All MEDLI2 hardware operated as expected during cruise and entry. MEDLI2 sensors gathered accurate pressure measurements in hypersonic through supersonic regimes to reconstruct vehicle attitude and atmospheric profiles. MEDLI2 on the heatshield sensors indicated that surface temperatures, caused by turbulent heating beginning 70 seconds after entry, remained at or below 1430 °C, while heatshield bondline temperatures rose less than 45 °C. Backshell surface TPS temperatures peaked at 630 °C, which was caused primarily by radiative heating measured by several separate sensors. The MEDLI2 temperature and pressure measurements enabled further detailed characterization of the Mars 2020 entry performance, and the flight dataset will provide a wealth of information for the EDL community and future mission designers.

thermal protection systems↗