Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

A Method for Assessing Ground-Truth Accuracy of the 5DCT Technique

Purpose: To develop a technique that assesses the accuracy of the breathing phase-specific volume image generation process by patient-specific breathing motion model using the original free-breathing computed tomographic (CT) scans as ground truths. Methods: Sixteen lung cancer patients underwent a previously published protocol in which 25 free-breathing fast helical CT scans were acquired with a simultaneous breathing surrogate. A patient-specific motion model was constructed based on the tissue displacements determined by a state-of-the-art deformable image registration. The first image was arbitrarily selected as the reference image. The motion model was used, along with the free-breathing phase information of the original 25 image datasets, to generate a set of deformation vector fields that mapped the reference image to the 24 nonreference images. The high-pitch helically acquired original scans served as ground truths because they captured the instantaneous tissue positions during free breathing. Image similarity between the simulated and the original scans was assessed using deformable registration that evaluated the pointwise discordance throughout the lungs. Results: Qualitative comparisons using image overlays showed excellent agreement between the simulated images and the original images. Even large 2-cm diaphragm displacements were very well modeled, as was sliding motion across the lung–chest wall boundary. The mean error across the patient cohort was 1.15 ± 0.37 mm, and the mean 95th percentile error was 2.47 ± 0.78 mm. Conclusion: The proposed ground truth–based technique provided voxel-by-voxel accuracy analysis that could identify organ-specific or tumor-specific motion modeling errors for treatment planning. Despite a large variety of breathing patterns and lung deformations during the free-breathing scanning session, the 5-dimensionl CT technique was able to accurately reproduce the original helical CT scans, suggesting its applicability to a wide range of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Developing techniques for crystal growth synthesis and characterization of rare earth-silicon-germanium magnetoresponsive alloys

In this study, a crystal growth technique was developed for the family of intermetallic, magnetoresponsive RE 5 (Si 1-x Ge x ) 4 alloys in order to access the intrinsic and anisotropic properties. Initial bulk properties measured on polycrystalline samples alluded to the properties being obscured or averaged and high-quality, well-characterized, single crystals would clarify this. Successful crystal growth led to development of oriented sample preparation techniques specific for the crystal structures (monoclinic and orthorhombic) and mechanical properties (hard and brittle) of these alloys, and customized for the various measurement techniques undertaken. Here we describe our journey, sometimes circuitous, from crystal growth to sample preparation and cite the scientific discoveries that came about as a result.

36 MATERIALS SCIENCE↗

The statistical analysis techniques to support the NGNP fuel performance experiments

This paper describes the development and application of statistical analysis techniques to support the Advanced Gas Reactor (AGR) experimental program on Next Generation Nuclear Plant (NGNP) fuel performance. The experiments conducted in the Idaho National Laboratory’s Advanced Test Reactor employ fuel compacts placed in a graphite cylinder shrouded by a steel capsule. The tests are instrumented with thermocouples embedded in graphite blocks and the target quantity (fuel temperature) is regulated by the He–Ne gas mixture that fills the gap volume. Three techniques for statistical analysis, namely control charting, correlation analysis, and regression analysis, are implemented in the NGNP Data Management and Analysis System for automated processing and qualification of the AGR measured data. The neutronic and thermal code simulation results are used for comparative scrutiny. The ultimate objective of this work includes (a) a multi-faceted system for data monitoring and data accuracy testing, (b) identification of possible modes of diagnostics deterioration and changes in experimental conditions, (c) qualification of data for use in code validation, and (d) identification and use of data trends to support effective control of test conditions with respect to the test target. Analysis results and examples given in the paper show the three statistical analysis techniques providing a complementary capability to warn of thermocouple failures. It also suggests that the regression analysis models relating calculated fuel temperatures and thermocouple readings can enable online regulation of experimental parameters (i.e. gas mixture content), to effectively maintain the fuel temperature within a given range.

99 GENERAL AND MISCELLANEOUS↗

High performance dye-sensitized solar cells using graphene modified fluorine-doped tin oxide glass by Langmuir–Blodgett technique

Since the introduction of dye-sensitized solar cells (DSSCs) with low fabrication cost and high power conversion efficiency, extensive studies have been carried out to improve the charge transfer rate and performance of DSSCs. In this paper, we present DSSCs that use surface modified fluorine-doped tin oxide (FTO) substrates with reduced graphene oxide (r-GO) sheets prepared using the Langmuir–Blodgett (LB) technique to decrease the charge recombination at the TiO{sub 2}/FTO interface. R-GO sheets were excellently attached on FTO surface without physical deformations such as wrinkles; effects of the surface coverage of r-GO on the DSSC performance were also investigated. By using graphene modified FTO substrates, the resistance at the interface of TiO{sub 2}/FTO was reduced and the power conversion efficiency was increased to 8.44%. - Graphical abstract: DSSCs with graphene modified FTO glass were fabricated with the Langmuir Blodgett technique. GO sheets were transferred to FTO at various surface pressures in order to change the surface density of graphene and the highest power conversion efficiency of the DSSC was 8.44%. - Highlights: • By LB technique, r-GO sheets were coated on FTO without physical deformation. • DSSCs were fabricated with, r-GO modified FTO substrates. • With surface modification by r-GO, the interface resistance of DSSC decreased. • Maximum PCE of the DSSC was increased up to 8.44%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metallographic techniques for evaluation of Thermal Barrier Coatings produced by Electron Beam Physical Vapor Deposition

Thermal Barrier Coatings (TBC) produced by Electron Beam Physical Vapor Deposition (EB-PVD) are primarily applied to critical hot section turbine components. EB-PVD TBC for turbine applications exhibit a complicated structure of porous ceramic columns separated by voids that offers mechanical compliance. Currently there are no standard evaluation methods for evaluating EB-PVD TBC structure quantitatively. This paper proposes a metallographic method for preparing samples and evaluating techniques to quantitatively measure structure. TBC samples were produced and evaluated with the proposed metallographic technique and digital image analysis for columnar grain size and relative intercolumnar porosity. Incorporation of the proposed evaluation technique will increase knowledge of the relation between processing parameters and material properties by incorporating a structural link. Application of this evaluation method will directly benefit areas of quality control, microstructural model development, and reduced development time for process scaling.

36 MATERIALS SCIENCE↗

Characterisation of titanium-titanium boride composites processed by powder metallurgy techniques

In this work, a detailed characterisation of titanium-titanium boride composites processed by three powder metallurgy techniques, namely, hot isostatic pressing, spark plasma sintering and vacuum sintering, was conducted. Two composites with different volume percents of titanium boride reinforcement were used for the investigation. One was titanium with 20% titanium boride, and the other was titanium with 40% titanium boride (by volume). Characterisation was performed using X-ray diffraction, electron probe micro analysis - energy dispersive spectroscopy and wavelength dispersive spectroscopy, image analysis and scanning electron microscopy. The characterisation results confirm the completion of the titanium boride reaction. The results reveal the presence of titanium boride reinforcement in different morphologies such as needle-shaped whiskers, short agglomerated whiskers and fine plates. The paper also discusses how mechanical properties such as microhardness, elastic modulus and Poisson's ratio are influenced by the processing techniques as well as the volume fraction of the titanium boride reinforcement. - Highlights: Black-Right-Pointing-Pointer Ti-TiB composites were processed by HIP, SPS and vacuum sintering. Black-Right-Pointing-Pointer The completion of Ti-TiB{sub 2} reaction was confirmed by XRD, SEM and EPMA studies. Black-Right-Pointing-Pointer Hardness and elastic properties of Ti-TiB composites were discussed. Black-Right-Pointing-Pointer Processing techniques were compared with respect to their microstructure.

36 MATERIALS SCIENCE↗

The relationships between residual stress relaxation and texture development in AZ31 Mg alloys via the vibratory stress relief technique

A systematic study of residual stress relaxation and the texture evolution of cold-rolled AZ31 Mg alloys using the vibratory stress relief technique with a simple cantilever beam vibration system was performed using a high-resolution X-ray diffractometer and a portable X-ray residual stress analyzer. The effects of vibrational stress excitation on the surface residual stress distribution and on the texture of pole figures (0002) occurring during the vibratory stress relief were examined. Compared with the effects corresponding to the same alloy under non-vibration condition, it can be observed that the uniform surface residual stress distribution and relaxation of the compressive residual stress in the stress concentration zone were observed rather than all of the residual stresses being eliminated. Furthermore, with an increase in the vibrational aging time, the compressive residual stress, texture density, and (0002) preferred orientation increased first and then decreased. It should be underlined that the vibratory stress relief process for the vibrational aging time of more than 10 min is able to weaken the strong basal textures of AZ31 Mg alloys, which is valuable for enhancement of their formability and is responsible for an almost perfect 3D-Debye–Scherrer ring. - Highlights: • 3D-Debye ring about VSR technique is not discussed in the existing literature. • A newly developed VSR method is suitable for small or thin workpieces. • The cosα method accurately and effectively determines the residual stresses. • The VSR technique is valuable for enhancement of their formability. • The texture and preferred orientation change with the vibrational aging time.

36 MATERIALS SCIENCE↗

Transfer of microstructure pattern of CNTs onto flexible substrate using hot press technique for sensing applications

Graphical abstract: - Highlights: • Successfully transfer of microstructure patterned CNTs on PET substrate. • Demonstrate as resistor-based NH{sub 3} gas sensor in the sub-ppm range. • Excellent photodetector having instantaneous response and recovery characteristics. • An effective technique to grow and produce flexible electronic device. - Abstract: In this work, we report the successful and efficient transfer process of two- dimensional (2-D) vertically aligned carbon nanotubes (CNTs) onto polyethylene terephthalate (PET) substrate by hot pressing method with an aim to develop flexible sensor devices. Carbon nanotubes are synthesized by cold wall thermal chemical vapor deposition using patterned SiO{sub 2} substrate under low pressure. The height of the pattern of CNTs is controlled by reaction time. The entire growth and transfer process is carried out within 30 min. Strong adhesion between the nanotube and polyethylene terephthalate substrate was observed in the post-transferred case. Raman spectroscopy and scanning electron microscope (SEM) studies are used to analyze the microstructure of carbon nanotube film before and after hot pressing. This technique shows great potential for the fabrication of flexible sensing devices. We report for the first time, the application of patterned microstructure developed by this technique in the development of gas sensor and optoelectronic device. Surface resistive mode is used for detection of ammonia (NH{sub 3}) gas in the sub-ppm range. An impressive photoconducting response is also observed in the visible wavelength. The reproducibility of the sample was checked and the results indicate the possibility of use of carbon nanotube as gas sensor, photodetector, CCDs etc.

36 MATERIALS SCIENCE↗

Comparison of purity in single walled carbon nanotube gas detectors with Pd and Ti electrodes using low frequency noise techniques

This work deals with oxide traps properties of single walled carbon nanotubes (SWCNTs) based gas sensors using Random telegraph signals (RTS) and low frequency (LF) noise techniques. RTS signals are two or more levels switching events that we observe measuring the drain current of transistors with Ti (RTS{sub 1}) and Pd (RTS{sub 2}) contacts. RTS noise is analyzed in time and frequency domains. Time domain analysis allows us to identifying slow traps (three traps) responsible to RTS noises (energetic position and cross capture section). These traps undetectable by other techniques, e.g. deep level transient spectroscopy (DLTS) technique, are localized in the gate oxide region. The spatial localization of the three traps in the SWCNT/SiO{sub 2} interface are determined using numerical simulations (y{sub Trap1} ≈0.6 nm, y{sub Trap2} ≈0.9 nm and y{sub Trap3} ≈0.3 nm). (RTS{sub 1}) noise is attributed to trap1 and (RTS{sub 2}) to traps 2 and 3. From RTS analysis in frequency domain, are able to extract the cut-off frequencies of a single trap even at very low frequencies (for RTS{sub 1} noise f{sub c} = 10 Hz (trap1) and for RTS{sub 2} noise f{sub c1} = 4 Hz (trap2), f{sub c2} = 50 Hz (trap 3)). These results are in good agreement with those obtained by analysis in time domain and confirm the localization of each trap from the SWCNT/SiO{sub 2} interface. This is the first time that this kind of studies is performed on CNTFETs used as gas sensors and gives us some interesting hints on the potential phenomena related to these new generation of carbon based nanomaterials based devices in the field of electronics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effect of GLAD technique on optical properties of ZnS multilayer antireflection coatings

Highlights: • ZnS multi-layer antireflection coatings have been prepared by GLAD technique. • XRD analysis depicts that all the multi-layer samples are crystallized in cubic structure. • FESEM images confirmed the multi-layer and inclined formation of specimens. • Transmission increment and refractive index decrement obtained for the multi-layer samples. • Incredible impression of GLAD technique on multi-layer coatings is realized. - Abstract: In this work, we prepared Zinc sulfide (ZnS) multi-layer antireflection coatings applying glancing angle deposition (GLAD) technique by physical vapor deposition method. By comparing the structural and optical properties of the samples prepared at normal and inclined single layer coatings, salient effect of multi-layer coatings composed of normal and inclined layers are observed. Relative improvement in crystallinity of the GLAD produced films with respect to inclined single layer resulted from X-ray diffraction (XRD) studies. Despite high increment in average transmission, explicit reduction in refractive index of the multilayer specimens are obtained by Ultraviolet–visible spectroscopy (UV–VIS) analysis. Both the abovementioned changes are in the direction of improving the anti-reflectivity features.

36 MATERIALS SCIENCE↗

Electro-analytical method for the quantities evaluation of the silicon solar cell by DC and AC characterization technique

Highlights: • Exact electro-analytical method for evaluation of silicon solar cells. • DC and AC characterization technique to determine the performance limiting parameters of solar cells. • EIS is used to get an insight into the solar cells and parameter optimization. - Abstract: Mono and Poly- crystalline silicon (Si) based solar cell has proven to be the most efficient and matured technology till date. The present work reports an exact electro-analytical method for the evaluation of different performance parameters in the current voltage response of the Si solar cell by DC and AC characterization technique. The extracted solar cell parameters from DC and AC techniques were compared with each other under the proper limiting conditions of low and high forward bias. The DC and AC characterization are used to determine the bias dependence of ideality factor and series resistance, respectively. The current-voltage (J-V) characteristics is combined with the impedance spectroscopy (IS) measurements to reveal the various interfacial, resistive and recombination analysis of the silicon solar cell. Herein the experimentally obtained J-V characteristics under the illumination condition have been reconstructed by individually extracted parameters from DC and AC measurements. Moreover, the present mechanistic provides a simple tool for analysing the commercial Si solar cell with a wide applicability for other solar cells.

14 SOLAR ENERGY↗

Photothermal deflection technique investigation of thermal annealing effects of AlGaAsSb/GaSb laser structure: Non-radiative recombination parameters enhancement

Highlights: • Photothermal deflection technique is performed to mesuaure the nonradiative recombination parameters of AlGaAsSb/GaSb. • After annealing time process, nonradiative recombination parameters of AlGaAs / GaSb have been enhanced. • The largest nonradiative recombination values have been found for AlGaAsSb/GaSb annealed for 60 min - Abstract: Photothermal deflection technique (PTD) is used to investigate the effects of thermal annealing time on nonradiative recombination parameters i.e. nonradiative lifetime of minority carriers, electronic diffusion coefficient, and surface and interface recombination velocity of AlGaAsSb/GaSb laser structure. The extraction of the electronic parameters are performed by PTD technique through extensive modeling by fitting the experimental photothermal signal to the corresponding theoretical ones. We have found that nonradiative recombination parameters have been enhanced by annealing time. These results are very promising for improvement of active layer used for vertical-cavity surface-emitting lasers (VCSELs).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Performance of CH3NH3PbI3 - Nanoparticles based – Perovskite Solar Cells Fabricated by Facile Powder press Technique

Highlights: • Perovskite nanoparticles (PNs) were prepared using simple solid-state technique. • Perovskite layer has been deposited by facile powder press technique - a solution cum vacuum-free. • Fabricated device structure: FTO/c-TiO{sub 2}/mp-TiO{sub 2}/Perovskite/CuI/Cr/Pt-coated FTO. • 1:3 M ratio of PbI{sub 2} in MAI resulted in achieving a PCE of 3.90%. • From the stability test, it is inferred that deterioration in ‘η’ and ‘V{sub OC}’ was by 27.87% and 29.23% respectively. - Abstract: Here, we have introduced a facile solid-state route assisted method to prepare CH{sub 3}NH{sub 3}PbI{sub 3} perovskite nanoparticles (PNs) and together with a facile - powder press technique, for the deposition of prepared PNs - a solution cum vacuum-free route. The perovskite layer was prepared using different lead iodide (PbI{sub 2}) precursor molar concentrations (0.5, 1, 1.5, 2 mmol) and the PbI{sub 2} concentration was found to have a significant impact on the structural, optical, morphological and electrical properties. The sample prepared using molar ratio PbI{sub 2}: MAI at 1:3 shows the optimal bandgap value (∼1.51 eV), broader band edge peak at 755 nm and found have good optical property for photovoltaic (PV) applications. The J–V performance of the fabricated perovskite device with FTO/c-TiO{sub 2}/mp-TiO{sub 2}/Perovskite/CuI/ Cr/Pt-coated FTO counter electrode has been studied. The device fabricated using the concentration at PbI{sub 2}:MAI 1:3 achieved a PCE of 3.9% and resulted in better long-term stability with deterioration in η and V{sub OC} by 27.87% and 29.23% after 15 days.

14 SOLAR ENERGY↗

A Technique for Verification of Isocenter Position in Tangential Field Breast Irradiation

Treatment verification and reproducibility of the breast treatment portals play a very important role in breast radiotherapy. We propose a simple technique to verify the planned isocenter position during treatment using an electronic portal imaging device. Ten patients were recruited in this study and (CT) computed tomography-based planning was performed with a conventional tangential field technique. For verification purposes, in addition to the standard medial (F1) and lateral (F2) tangential fields, a field (F3) perpendicular to the medial field was used for verification of the treatment portals. Lead markers were placed along the central axis of the 2 defined fields (F1 and F3) and the separation between the markers was measured on the portal images and verified with the marker separation on the digitally reconstructed radiographs (DRRs). Any deviation will identify the shift in the planned isocenter position during treatment. The average deviation observed between the markers measured from the DRR and portal image was 1.6 and 2.1 mm, with a standard deviation of 0.4 and 0.9 mm for fields F1 and F3, respectively. The maximum deviation observed was 3.0 mm for field F3. This technique will be very useful in patient setup for tangential breast radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Study and Verification of Total Body Irradiation Using Helical Tomotherapy and its Comparison to Extended SSD Technique

The American College of Radiology practice guideline for total body irradiation (TBI) requires a back-up treatment delivery system. This study investigates the development of helical tomotherapy (HT) for delivering TBI and compares it with conventional extended source-to-surface distance (X-SSD) technique. Four patients' head-to-thigh computed tomographic images were used in this study, with the target defined as the body volume without the left and right lungs. HT treatment plans with the standard TBI prescription (1.2 Gy/fx, 10 fractions) were generated and verified on phantoms. To compare HT plans with X-SSD treatment, the dose distribution of X-SSD technique was simulated using the Eclipse software. The average dose received by 90% of the target volume was 12.3 Gy (range, 12.2-12.4 Gy) for HT plans and 10.3 Gy (range, 10.08-10.58 Gy) for X-SSD plans (p < 0.001). The left and right lung median doses were 5.44 Gy and 5.40 Gy, respectively, for HT plans and 8.34 Gy and 8.95 Gy, respectively, for X-SSD treatment. The treatment planning time was comparable between the two methods. The beam delivery time of HT treatment was longer than X-SSD treatment. In conclusion, HT-based TBI plans have better dose coverage to the target and better dose sparing to the lungs compared with X-SSD technique, which applies dose compensators, lung blocks, and electron boosts. This study demonstrates that HT is possible for delivering TBI. Clinical validation of the feasibility of this approach would be of interest in the future.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

A Technique for Stereotactic Radiosurgery Treatment Planning with Helical Tomotherapy

The purpose of this study was to develop an efficient and effective planning technique for stereotactic radiosurgery using helical tomotherapy. Planning CTs and contours of 20 patients, previously treated in our clinic for brain metastases with linac-based radiosurgery using circular collimators, were used to develop a robust TomoTherapy planning technique. Plan calculation times as well as delivery times were recorded for all patients to allow for an efficiency evaluation. In addition, conformation and homogeneity indices were calculated as metrics to compare plan quality with that which is achieved with conventional radiosurgery delivery systems. A robust and efficient planning technique was identified to produce plans of radiosurgical quality using the TomoTherapy treatment planning system. Dose calculation did not exceed a few hours and resulting delivery times were less than 1 hour, which allows the process to fit into a single day radiosurgery workflow. Plan conformity compared favorably with published results for gamma knife radiosurgery. In addition, plan homogeneity was similar to linac-based approaches. The TomoTherapy planning software can be used to create plans of acceptable quality for stereotactic radiosurgery in a time that is appropriate for a radiosurgery workflow that requires that planning and delivery occur within 1 treatment day.

61 RADIATION PROTECTION AND DOSIMETRY↗

Simplified field-in-field technique for a large-scale implementation in breast radiation treatment

We wanted to evaluate a simplified 'field-in-field' technique (SFF) that was implemented in our department of Radiation Oncology for breast treatment. This study evaluated 15 consecutive patients treated with a simplified field in field technique after breast-conserving surgery for early-stage breast cancer. Radiotherapy consisted of whole-breast irradiation to the total dose of 50 Gy in 25 fractions, and a boost of 16 Gy in 8 fractions to the tumor bed. We compared dosimetric outcomes of SFF to state-of-the-art electronic surface compensation (ESC) with dynamic leaves. An analysis of early skin toxicity of a population of 15 patients was performed. The median volume receiving at least 95% of the prescribed dose was 763 mL (range, 347-1472) for SFF vs. 779 mL (range, 349-1494) for ESC. The median residual 107% isodose was 0.1 mL (range, 0-63) for SFF and 1.9 mL (range, 0-57) for ESC. Monitor units were on average 25% higher in ESC plans compared with SFF. No patient treated with SFF had acute side effects superior to grade 1-NCI scale. SFF created homogenous 3D dose distributions equivalent to electronic surface compensation with dynamic leaves. It allowed the integration of a forward planned concomitant tumor bed boost as an additional multileaf collimator subfield of the tangential fields. Compared with electronic surface compensation with dynamic leaves, shorter treatment times allowed better radiation protection to the patient. Low-grade acute toxicity evaluated weekly during treatment and 2 months after treatment completion justified the pursuit of this technique for all breast patients in our department.

61 RADIATION PROTECTION AND DOSIMETRY↗

HybridArc: A novel radiation therapy technique combining optimized dynamic arcs and intensity modulation

This investigation focuses on possible dosimetric and efficiency advantages of HybridArc-a novel treatment planning approach combining optimized dynamic arcs with intensity-modulated radiation therapy (IMRT) beams. Application of this technique to two disparate sites, complex cranial tumors, and prostate was examined. HybridArc plans were compared with either dynamic conformal arc (DCA) or IMRT plans to determine whether HybridArc offers a synergy through combination of these 2 techniques. Plans were compared with regard to target volume dose conformity, target volume dose homogeneity, sparing of proximal organs at risk, normal tissue sparing, and monitor unit (MU) efficiency. For cranial cases, HybridArc produced significantly improved dose conformity compared with both DCA and IMRT but did not improve sparing of the brainstem or optic chiasm. For prostate cases, conformity was improved compared with DCA but not IMRT. Compared with IMRT, the dose homogeneity in the planning target volume was improved, and the maximum doses received by the bladder and rectum were reduced. Both arc-based techniques distribute peripheral dose over larger volumes of normal tissue compared with IMRT, whereas HybridArc involved slightly greater volumes of normal tissues compared with DCA. Compared with IMRT, cranial cases required 38% more MUs, whereas for prostate cases, MUs were reduced by 7%. For cranial cases, HybridArc improves dose conformity to the target. For prostate cases, dose conformity and homogeneity are improved compared with DCA and IMRT, respectively. Compared with IMRT, whether required MUs increase or decrease with HybridArc was site-dependent.

61 RADIATION PROTECTION AND DOSIMETRY↗