Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolution data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

PACE Technical Report Series, Volume 7: Ocean Color Instrument (OCI) Concept Design Studies

Extending OCI hyperspectral radiance measurements in the ultraviolet to 320 nm on the blue spectrograph enables quantitation of atmospheric total column ozone (O3) for use in ocean color atmospheric correction algorithms. The strong absorption by atmospheric ozone below 340 nm enables the quantification of total column ozone. Other applications are possible but were not investigated due to their exploratory nature and lower priority.The first step in the atmospheric correction processing, which converts top-of-the-atmosphere radiances to water-leaving radiances, is removal of the absorbance by atmospheric trace gases such as water vapor, oxygen, ozone and nitrogen dioxide. Details of the atmospheric correction process currently used by the Ocean Biology Processing Group (OBPG) and will be employed for PACE with appropriate modifications, are described by Mobley et al. [2016]. Atmospheric ozone absorbs within the visible to near-infrared spectrum between ~450 nm and 800nm and most appreciably between 530 nm and 650 nm, a spectral region critical for maintaining NASA's chlorophyll-a climate data record and for PACE algorithms planned to characterize phytoplankton community composition and other ocean color products.While satellite-based observations will likely be available during PACE's mission lifetime, the difference in acquisition time with PACE, the coarseness in their spatial resolution, and differences in viewing geometries will introduce significant levels of uncertainties in PACE ocean color data products.

Cetinic, Ivona↗

Compressive Sensing Application for Transient Photometric Measurements

Compressive Sensing (CS) is a mathematical theory for simultaneous data acquisition and compression. Natural phenomena may be sparse in some physical or temporal domain. If we exploit this sparsity by applying the technique of CS to obtain information, how do our measurements change as a function of domain and measurement systematics? What are the specific implications for the science and for the sensing infrastructure? In this talk, we will discuss the generalized systematic effects consequent to the application of CS to time-series photometric measurements. We assess implications for observability, sparsification, and information loss in the detection, retrieval and reconstruction process. To study time-series photometry, we explore the field of gravitational microlensing. A source star, typically in the galactic bulge, gets microlensed when there is a precise alignment of a lensing star and its planetary system, with the source star. The microlensed source star changes in flux magnification as the lensing system crosses the precise path of alignment, resulting in a microlensing curve in time domain. A high-cadence, high-resolution system, which uses low power and bandwidth is essential to obtain valuable science measurements. Hence, we discuss application of CS to gravitational microlensing data sets, which in turn can be generalized to any time-ordered photometric measurements.

Asmita Abhay Korde↗

Inductive electric field at the magnetopause

The electric field data for two crossings of the magnetopause by ISEE-1 on November 20, 1977, have been analyzed with high time resolution. In both cases the electric field has a negative dawn-dusk component in the boundary layer, so it must reverse somewhere within the current layer to the positive value outside. If there is a component parallel to the moving magnetopause current it is small, and by no means obvious. In the case of the exit crossing from the boundary layer to the magnetosheath the data show that the electric field vector is turning for about two seconds at roughly the satellite spin rate; this changing direction suggests that the electric field has a curl. Such a curl could be caused by a travelling localized perturbation of the magnetopause surface current associated with impulsive plasma transport through the magnetopause.

Heikkila, W. J.↗

Comparing Satellite Measurements of Volcanic SO2 Mass from OMI, OMPS and TROPOMI

Sulfur dioxide (SO2) is a major air pollutant that contributes to acid rain and aerosol formation (e.g., sulfates), adversely affects the environment and human health, and explosive volcanic SO2 emissions can impact climate. The majority of SO2 emissions are related to anthropogenic processes (e.g., fossil fuel burning, metal ore smelting operations), although natural processes such as volcanic eruptions and degassing also play an important role as anthropogenic SO2 emissions continue to decline. Generally, the most interest in volcanoes occurs during major eruptions. We will focus on comparing volcanic SO2 outgassing that occurs on an almost daily basis from lesser known volcanoes using satellite data. At NASA’s Global Sulfur Dioxide Monitoring Home page (https://so2.gsfc.nasa.gov/), we have been posting daily SO2 maps from 40 volcanic and industrial regions around the world using measurements from three satellite instruments; the Ozone Monitoring Instrument (OMI) onboard NASA’s Earth Observing System Aura satellite, the Ozone Monitoring and Profiler Suite (OMPS) onboard the NASA-NOAA Suomi National Polar-orbiting Partnership (NPP) satellite, and the TROPOspheric Monitoring Instrument (TROPOMI) onboard the ESA/Copernicus Sentinel-5 Precursor satellite. These instruments in low Earth sun-synchronous polar orbits with 1:30-2:00 pm equator crossing local time provide daily SO2 maps at different spatial resolutions: 13 x 24 km2, 50 x 50 km2 and 5.5 x 3.5 km2 for OMI, OMPS and TROPOMI respectively. Data from OMI are available since October 2004 (partial coverage since 2008), from OMPS since 2012 and from TROPOMI since 2018. We will present comparative SO2 mass time-series (see Hunga-Tonga plot) and statistical analyses of recent eruptions that have data from all the instruments.

SO2↗

Understanding reliability and some limitations of the images and spectra reconstructed from a multi-monochromatic x-ray imager

Temperature and density asymmetry diagnosis is critical to advance inertial confinement fusion (ICF) science. A multi-monochromatic x-ray imager (MMI) is an attractive diagnostic for this purpose. The MMI records the spectral signature from an ICF implosion core with time resolution, 2-D space resolution, and spectral resolution. While narrow-band images and 2-D space-resolved spectra from the MMI data constrain temperature and density spatial structure of the core, the accuracy of the images and spectra depends not only on the quality of the MMI data but also on the reliability of the post-processing tools. In this paper, we synthetically quantify the accuracy of images and spectra reconstructed from MMI data. Errors in the reconstructed images are less than a few percent when the space-resolution effect is applied to the modeled images. The errors in the reconstructed 2-D space-resolved spectra are also less than a few percent except those for the peripheral regions. Spectra reconstructed for the peripheral regions have slightly but systematically lower intensities by ~6% due to the instrumental spatial-resolution effects. However, this does not alter the relative line ratios and widths and thus does not affect the temperature and density diagnostics. We also investigate the impact of the pinhole size variation on the extracted images and spectra. A 10% pinhole size variation could introduce spatial bias to the images and spectra of ~10%. A correction algorithm is developed, and it successfully reduces the errors to a few percent. Finally, it is desirable to perform similar synthetic investigations to fully understand the reliability and limitations of each MMI application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monitoring Surface Phenomena Created by an Underground Chemical Explosion Using Fully Polarimetric VideoSAR

Sandia National Laboratories flew its Facility for Advanced RF and Algorithm Development X-Band (9.6-GHz center frequency), fully polarimetric synthetic aperture radar (PolSAR) in VideoSAR mode to collect complex-valued SAR imagery before, during, and after the sixth Source Physics Experiment's (SPE-6) underground explosion. The VideoSAR products generated from the data sets include "movies'' of single- and quad-polarization coherence maps, magnitude imagery, and polarimetric decompositions. Residual defocus, due to platform motion during data acquisition, was corrected with a digital elevation model-based autofocus algorithm. We generated and exploited the VideoSAR image products to characterize the surface movement effects caused by the underground explosion. Unlike seismic sensors, which measure local area seismic waves using sparse spacing and subterranean positioning, these VideoSAR products captured high-spatial resolution, 2-D, time-varying surface movement. The results from the fifth SPE (SPE-5) used single-polarimetric VideoSAR data. In this paper, we present single-polarimetric and fully polarimetric VideoSAR results while monitoring the SPE-6 underground chemical explosion. We show that fully polarimetric VideoSAR imaging provides a unique, coherent, time-varying measure of the surface expression of the SPE-6 underground chemical explosion. As a result, we include new surface characterization results from the measured PolSAR SPE-6 data via H/A/α polarimetric decomposition.

47 OTHER INSTRUMENTATION↗

Alaskan Auroral All-Sky Images on the World Wide Web

In response to a 1995 NASA SPDS announcement of support for preservation and distribution of important data sets online, the Geophysical Institute, University of Alaska Fairbanks, Alaska, proposed to provide World Wide Web access to the Poker Flat Auroral All-sky Camera images in real time. The Poker auroral all-sky camera is located in the Davis Science Operation Center at Poker Flat Rocket Range about 30 miles north-east of Fairbanks, Alaska, and is connected, through a microwave link, with the Geophysical Institute where we maintain the data base linked to the Web. To protect the low light-level all-sky TV camera from damage due to excessive light, we only operate during the winter season when the moon is down. The camera and data acquisition is now fully computer controlled. Digital images are transmitted each minute to the Web linked data base where the data are available in a number of different presentations: (1) Individual JPEG compressed images (1 minute resolution); (2) Time lapse MPEG movie of the stored images; and (3) A meridional plot of the entire night activity.

Stenbaek-Nielsen, H. C.↗

Observations of Turbulence in a Kelvin-Helmholtz Event on 8 September 2015 by the Magnetospheric Multiscale Mission

Spatial and high-time-resolution properties of the velocities, magnetic field, and 3-D electric field within plasma turbulence are examined observationally using data from the Magnetospheric Multiscale mission. Observations from a Kelvin-Helmholtz instability (KHI) on the Earth's magnetopause are examined, which both provides a series of repeatable intervals to analyze, giving better statistics, and provides a first look at the properties of turbulence in the KHI. For the first time direct observations of both the high-frequency ion and electron velocity spectra are examined, showing differing ion and electron behavior at kinetic scales. Temporal spectra exhibit power law behavior with changes in slope near the ion gyrofrequency and lower hybrid frequency. The work provides the first observational evidence for turbulent intermittency and anisotropy consistent with quasi two-dimensional turbulence in association with the KHI. The behavior of kinetic-scale intermittency is found to have differences from previous studies of solar wind turbulence, leading to novel insights on the turbulent dynamics in the KHI.

Stawarz, J. E.↗

Integrated hydrogeophysical modelling and data assimilation for geoelectrical leak detection

Time-lapse electrical resistivity tomography (ERT) measurements provide indirect observations of hydrological processes in the Earth's shallow subsurface at high spatial and temporal resolution. ERT has been used in the past decades to detect leaks and monitor the evolution of associated contaminant plumes. Specifically, inverted resistivity images allow visualization of the dynamic changes in the structure of the plume. However, existing methods do not allow the direct estimation of leak parameters (e.g. leak rate, location, etc.) and their uncertainties. We propose an ensemble-based data assimilation framework that evaluates proposed hydrological models against observed time-lapse ERT measurements without directly inverting for the resistivities. Each proposed hydrological model is run through the parallel coupled hydro-geophysical simulation code PFLOTRAN-E4D to obtain simulated ERT measurements. The ensemble of model proposals is then updated using an iterative ensemble smoother. In this paper, we demonstrate the proposed framework on synthetic and field ERT data from controlled tracer injection experiments. Our results show that the approach allows joint identification of contaminant source location, initial release time, and solute loading from the cross-borehole time-lapse ERT data, alongside with an assessment of uncertainties in these estimates. We demonstrate a reduction in site-wide uncertainty by comparing the prior and posterior plume mass discharges at a selected image plane. This framework is particularly attractive to sites that have previously undergone extensive geological investigation (e.g., nuclear sites). It is well suited to complement ERT imaging and we discuss practical issues in its application to field problems.

58 GEOSCIENCES↗

Online Static Load Model Estimation in Distribution Systems: Preprint

The paper focuses on parameter identification for time varying voltage dependent polynomial load models, namely the constant impedance (Z), constant current (I), and constant power (P), in the distribution systems. Typically, parameter identification has been done for aggregated loads at substations for the transmission planning studies. Given the higher voltage volatility faced by active distribution systems, this paper takes the load model estimation to the distribution networks. The paper assumes the presence of measurements at the distribution nodes from various sources, each at varying temporal resolutions. Least squares estimation (LSE) method with bounded variables is used to convert the measurements into ZIP parameter estimations for loads at various locations of the feeder. The results and discussions focus on some of the estimation issues faced in a distribution system due to varying voltage sensitivities of loads along a feeder, measurement resolution, impact of window size and sampling rate of measurement data, and the use of dynamic simulations to create synthetic measurement data in the absence of real ones.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Feasibility Study to Determine Cooling Time and Burnup of ATR Fuel Using a Nondestructive Technique and Three Types of Gamma-ray Detectors

A Feasibility Study to Determine Cooling Time and Burnup of ATR Fuel Using a Nondestructive Technique1 Rahmat Aryaeinejad, Jorge Navarro, and David W Nigg Idaho National Laboratory Abstract Effective and efficient Advanced Test Reactor (ATR) fuel management require state of the art core modeling tools. These new tools will need isotopic and burnup validation data before they are put into production. To create isotopic, burn up validation libraries and to determine the setup for permanent fuel scanner system a feasibility study was perform. The study consisted in measuring short and long cooling time fuel elements at the ATR canal. Three gamma spectroscopy detectors (HPGe, LaBr3, and HPXe) and two system configurations (above and under water) were used in the feasibility study. The first stage of the study was to investigate which detector and system configuration would be better suited for different scenarios. The second stage of the feasibility study was to create burnup and cooling time calibrations using experimental isotopic data collected and ORIGEN 2.2 burnup data. The results of the study establish that a better spectra resolution is achieve with an above the water configuration and that three detectors can be used in the permanent fuel scanner system for different situations. In addition it was conclude that a number of isotopic ratios and absolute measurements could be used to predict ATR fuel burnup and cooling times. 1This work was supported by the U.S. Depart¬ment of Energy (DOE) under Battelle Energy Alliance, LLC Contract No. DE-AC07-05ID14517.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DWT-Based Aggregated Load Modeling and Evaluation for Quasi-Static Time-Series Simulation on Distribution Feeders

This paper presents an extension of a previously reported discrete wavelet transform (DWT) based load modeling methodology which targets at modeling time-series load profiles to enable the more effective and realistic quasi-static time-series simulation of distribution feeders. The time-series load model is composed of two major parts: 1) The low-resolution field-measured load data which usually have a resolution of 30 or 15 min., 2) The high-resolution load variability model data extracted from the established variability database which can have resolution up to 1 sec. A load aggregation methodology is developed to aggregate the load profiles so that load profiles at different transformer ratings can be effectively modeled. Validation, evaluation, and analysis of the developed load modeling approach has been performed on the IEEE-123 feeder and an actual utility feeder from California. The analysis completed on the two feeders have demonstrated the effectiveness and revealed the value of the developed model for distribution feeder quasi-static time-series simulation at high temporal resolution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DWT-Based Aggregated Load Modeling and Evaluation for Quasi-Static Time-Series Simulation on Distribution Feeders: Preprint

This paper presents an extension of a previously reported discrete wavelet transform (DWT) based load modeling methodology which targets at modeling time-series load profiles to enable the more effective and realistic quasi-static time-series simulation of distribution feeders. The time-series load model is composed of two major parts: 1) The low-resolution field-measured load data which usually have a resolution of 30 or 15 min., 2) The high-resolution load variability model data extracted from the established variability database which can have resolution up to 1 sec. A load aggregation methodology is developed to aggregate the load profiles so that load profiles at different transformer ratings can be effectively modeled. Validation, evaluation, and analysis of the developed load modeling approach has been performed on the IEEE-123 feeder and an actual utility feeder from California. The analysis completed on the two feeders have demonstrated the effectiveness and revealed the value of the developed model for distribution feeder quasi-static time-series simulation at high temporal resolution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predictive Factors for Acute and Late Urinary Toxicity After Permanent Prostate Brachytherapy: Long-Term Outcome in 712 Consecutive Patients

Purpose: To describe the frequency of acute and late Radiation Therapy Oncology Group (RTOG) urinary toxicity, associated predictive factors, and resolution of International Prostate Symptom Score (IPSS) in 712 consecutive prostate brachytherapy patients. Methods and Materials: Patients underwent implantation between 1998 and 2003 (median follow-up, 57 months). The IPSS and RTOG toxicity data were prospectively collected. The patient, treatment, and implant factors were examined for an association with urinary toxicity. The time to IPSS resolution was examined using Kaplan-Meier curves, and multivariate modeling of IPSS resolution was done using Cox proportional hazards regression analysis. Logistic regression analysis was used to examine the factors associated with urinary toxicity. Results: The IPSS returned to baseline at a median of 12.6 months. On multivariate analysis, patients with a high baseline IPSS had a quicker resolution of their IPSS. Higher prostate D90 (dose covering 90% of the prostate), maximal postimplant IPSS, and urinary retention slowed the IPSS resolution time. The rate of the actuarial 5-year late urinary (>12 months) RTOG Grade 0, 1, 2, 3, and 4 was 32%, 36%, 24%, 6.2%, and 0.1%, respectively. At 7 years, the prevalence of RTOG Grade 0-1 was 92.5%. Patients with a larger prostate volume, greater number of needles, greater baseline IPSS, and use of hormonal therapy had more acute toxicity. On multivariate analysis, the significant predictors for late greater than or equal to RTOG toxicity 2 were a greater baseline IPSS, maximal postimplant IPSS, presence of acute toxicity, and higher prostate V150 (volume of the prostate covered by 150% of the dose). More recently implanted patients had less acute urinary toxicity and patients given hormonal therapy had less late urinary toxicity (all p < 0.02). Conclusion: Most urinary symptoms resolved within 12 months after prostate brachytherapy, and significant long-term urinary toxicity was very low. Refined patient selection and greater technical experience in prostate brachytherapy were associated with less urinary toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High frequency, high time resolution time-to-digital converter employing passive resonating circuits

A method for measuring time intervals accurate to the picosecond range is based on phase measurements of oscillating waveforms synchronous with their beginning and/or end. The oscillation is generated by triggering an LC resonant circuit, whose capacitance is precharged. By using high Q resonators and a final active quenching of the oscillation, it is possible to conjugate high time resolution and a small measurement time, which allows a high measurement rate. Methods for fast analysis of the data are considered and discussed with reference to computing resource requirements, speed, and accuracy. Experimental tests show the feasibility of the method and a time accuracy better than 4 ps rms. Methods aimed at further reducing hardware resources are finally discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-lapse 3-D electrical resistance tomography inversion for crosswell monitoring of dissolved and supercritical CO 2 flow at two field sites: Escatawpa and Cranfield, Mississippi, USA

In this study, we advance the understanding of three-dimensional (3-D) electrical resistivity tomography (ERT) for monitoring long-term CO 2 storage by analyzing two previously published field time-lapse data sets. We address two important aspects of ERT inversion-the issue of resolution decay, a general impediment to the ERT method, and the issue of potentially misleading imaging artifacts due to 2-D model assumptions. The first study analyzes data from a shallow dissolved-CO 2 injection experiment near Escatawpa (Mississippi), where ERT data were collected in a 3-D crosswell configuration. Here, we apply a focusing approach designed for crosswell configurations to counteract resolution loss in the inter-wellbore area, with synthetic studies demonstrating its effectiveness. The 3-D field data analysis reveals an initially southwards-trending flow path development and a dispersing plume development in the downgradient inter-well region. The second data set was collected during a deep (over 3 km) injection of supercritical CO 2 near Cranfield (Mississippi). Comparative 2-D and 3-D inversions reveal the projection of off-planar anomalies onto the cross-section, a typical artifact introduced by 2-D model assumptions. Conforming 3-D images from two different algorithms support earlier hydrological investigations, indicating a conduit system where flow velocity variations lead to a circumvention of a close observation well and an onset of increased CO 2 saturation downgradient from this well. We relate lateral permeability variations indicated by an independently obtained hydrological analysis to this consistently observed pattern in the CO 2 spatial plume evolution.

3-D inversion↗

Oxidation of lithium plasma facing components and its effect on plasma performance in the lithium tokamak experiment-β

The characteristics of lithium-coated plasma-facing components (PFCs) have been correlated with plasma performance on the lithium tokamak experiment-β (LTX-β). Previous experiments on LTX showed that the application of lithium to PFCs was needed to achieve higher performance discharges with flat electron temperature profiles and high edge temperatures. Samples that match the LTX-β PFCs were exposed to plasmas before and after PFCs were coated with lithium and transferred under vacuum to a surface analysis station. Measurements using x-ray photoelectron spectroscopy (XPS) revealed that the primary surface constituent was lithium oxide. Earlier XPS analysis of lithium-coated PFCs on LTX was only able to show the presence of surface oxygen. The new XPS data from LTX-β have sufficient resolution to clearly identify lithium compounds for the first time, and enable them to be correlated with how lithium-coated PFCs can reduce impurities and retain hydrogen to reduce recycling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Far-field thermal imaging below diffraction limit

Non-uniform self-heating and temperature hotspots are major concerns compromising the performance and reliability of submicron electronic and optoelectronic devices. At deep submicron scales where effects such as contact-related artifacts and diffraction limits accurate measurements of temperature hotspots, non-contact thermal characterization can be extremely valuable. In this work, we use a Bayesian optimization framework with generalized Gaussian Markov random field (GGMRF) prior model to obtain accurate full-field temperature distribution of self-heated metal interconnects from their thermoreflectance thermal images (TRI) with spatial resolution 2.5 times below Rayleigh limit for 530nm illumination. Finite element simulations along with TRI experimental data were used to characterize the point spread function of the optical imaging system. In addition, unlike iterative reconstruction algorithms that use ad hoc regularization parameters in their prior models to obtain the best quality image, we used numerical experiments and finite element modeling to estimate the regularization parameter for solving a real experimental inverse problem.

42 ENGINEERING↗