Search NASA⌕ Search

SEARCH · Search NASA

Results for “AMPLITUDE MODULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Beam test evaluation of electromagnetic calorimeter modules made from proton-damaged PbWO 4 crystals

The performance of electromagnetic calorimeter modules made of proton-irradiated PbWO 4 crystals has been studied in beam tests. The modules, similar to those used in the Endcaps of the CMS electromagnetic calorimeter (ECAL), were formed from 5×5 matrices of PbWO 4 crystals, which had previously been exposed to 24 GeV protons up to integrated fluences between 2.1 × 10 13 and 1.3 × 10 14 cm –2 . These correspond to the predicted charged-hadron fluences in the ECAL Endcaps at pseudorapidity η = 2.6 after about 500 fb –1 and 3000 fb –1 respectively, corresponding to the end of the LHC and High Luminosity LHC operation periods. The irradiated crystals have a lower light transmission for wavelengths corresponding to the scintillation light, and a correspondingly reduced light output. A comparison with four crystals irradiated in situ in CMS showed no significant rate dependence of hadron-induced damage. A degradation of the energy resolution and a non-linear response to electron showers are observed in damaged crystals. Direct measurements of the light output from the crystals show the amplitude decreasing and pulse becoming faster as the fluence increases. The latter is interpreted, through comparison with simulation, as a side-effect of the degradation in light transmission. In conclusion, the experimental results obtained can be used to estimate the long term performance of the CMS ECAL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion-acoustic super rogue waves in ultracold neutral plasmas with nonthermal electrons

The ion-acoustic rogue waves in ultracold neutral plasmas consisting of ion fluid and nonthermal electrons are reported. A reductive perturbation method is used to obtain a nonlinear Schrödinger equation for describing the system and the modulation instability of the ion-acoustic wave is analyzed. The critical wave number k{sub c}, which indicates where the modulational instability sets in, has been determined. Moreover, the possible region for the ion-acoustic rogue waves to exist is defined precisely. The effects of the nonthermal parameter β and the ions effective temperature ratio σ{sub *} on the critical wave number k{sub c} are studied. It is found that there are two critical wave numbers in our plasma system. For low wave number, increasing β would lead to cringe k{sub c} until β approaches to its critical value β{sub c}, then further increase of β beyond β{sub c} would enhance the values of k{sub c}. For large wave numbers, the increase of β would lead to a decrease of k{sub c}. However, increasing σ{sub *} would lead to the reduction of k{sub c} for all values of the wave number. The dependence of the rogue waves profile on the plasma parameters is numerically examined. It is found that the rogue wave amplitudes have complex behavior with increasing β. Furthermore, the enhancement of σ{sub *} and the carrier wave number k reduces the rogue wave amplitude. It is noticed that near to the critical wave number, the rogue wave amplitude becomes high, but it shrinks whenever we stepped away from k{sub c}. The implications of our results in laboratory ultracold neutral plasma experiments are briefly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quasimonoenergetic GeV electron bunch generation by the wake-field of the chirped laser pulse

One-dimensional nonlinear analysis of wake-field generation and electron bunch acceleration by a chirped laser pulse were investigated numerically. It was found that the optimum linear chirp parameter leads to the wake-field amplitude increase by one order of magnitude and accordingly the acceleration gradient. In our external injection scheme, electrons were accelerated using the initial energy of 100 KeV (gamma{sub in}=1.2). When the pulse passes through the electron bunch most part of the electrons trapped in the first cycle of the laser wake-field and accelerate to about 1 GeV in 1.8 mm. We concluded that the expensive electron preacceleration mechanism could be omitted in a laser-aided electron acceleration scheme.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scattering of radiofrequency waves by randomly modulated density interfaces in the edge of fusion plasmas

In the scrape-off layer and the edge region of a tokamak, the plasma is strongly turbulent and scatters the radiofrequency (RF) electromagnetic waves that propagate through this region. It is important to know the spectral properties of these scattered RF waves, whether used for diagnostics or for heating and current drive. The spectral changes influence the interpretation of the obtained diagnostic data, and the current and heating profiles. A full-wave, three-dimensional (3-D) electromagnetic code ScaRF has been developed for studying the RF wave propagation through turbulent plasma. ScaRF is a finite-difference frequency-domain (FDFD) method used for solving Maxwell's equations. The magnetized plasma is defined through the cold plasma by the anisotropic permittivity tensor. As a result, ScaRF can be used to study the scattering of any cold plasma RF wave. It can also be used for the study of the scattering of electron cyclotron waves in ITER-type and medium-sized tokamaks such as TCV, ASDEX-U and DIII-D. For the case of medium-sized tokamaks, there is experimental evidence that drift waves and rippling modes are present in the edge region. Hence, we have studied the scattering of RF waves by periodic density interfaces (plasma gratings) in the form of a superposition of spatial modes with varying periodicity and random amplitudes. The power reflection coefficient (a random variable) is calculated for different realizations of the density interface. In this work, the uncertainty of the power reflection coefficient is rigorously quantified by use of the Polynomial Chaos Expansion method in conjunction with the Smolyak sparse-grid integration, which is known as the PCE-SG method. The PCE-SG method is proven to be accurate and more efficient compared with alternative methods such as the Monte Carlo (MC) approach.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scattering of radio frequency waves by randomly modulated density interfaces in the edge of fusion plasmas

In the scrape-off layer and the edge region of a tokamak, the plasma is strongly turbulent and scatters the radio frequency (RF) electromagnetic waves that propagate through this region. It is important to know, whether used for diagnostics or for heating and current drive, the spectral properties of these scattered RF waves. The spectral changes influences the interpretation of the diagnostic-data obtained and the current and heating profiles. A full-wave, 3D electromagnetic code ScaRF (see Papadopoulos et al. 2019) has been developed for studying the RF wave propagation through turbulent plasma. ScaRF is a finite-difference frequency-domain (FDFD) method for solving Maxwell's equations. The magnetized plasma is defined through the cold plasma, anisotropic permittivity tensor. As a result, ScaRF can be used to study the scattering of any cold plasma RF wave. It can be for the study of scattering of electron cyclotron waves in ITER-type and medium-sized tokamaks such as TCV, ASDEX-U, DIII-D. For the case of medium-sized tokamaks, there's experimental evidence that drift waves and rippling modes are present in the edge region (see Ritz et al. 1984). Hence, we study the scattering of RF waves by periodic density interfaces (plasma gratings) in the form of a superposition of spatial modes with varying periodicity and random amplitudes (see Papadopoulos et al. 2019). The power reflection coefficient (a random variable) is calculated for different realizations of the density interface. In this work, the uncertainty of the power reflection coefficient is rigorously quantified by use of the Polynomial Chaos Expansion (see Xiu & Karniadakis 2002) method in conjunction with the Smolyak sparse grid integration (see Papadopoulos et al. 2018) (PCE-SG). The PCE-SG method is proven accurate and much more efficient (roughly 2-orders of magnitude shorter execution time) compared to alternative methods such as the Monte Carlo (MC) approach.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

How Would the Twenty-First-Century Warming Influence Pacific Decadal Variability and Its Connection to North American Rainfall: Assessment Based on a Revised Procedure for the IPO/PDO

Decadal climate variability of sea surface temperature (SST) over the Pacific Ocean can be characterized by interdecadal Pacific oscillation (IPO) or Pacific decadal oscillation (PDO) based on empirical orthogonal function (EOF) analysis. Although the procedures to derive the IPO and PDO indices differ in their regional focuses and filtering methods to remove interannual variability, the IPO and PDO are highly correlated in time and are often used interchangeably. Studies have shown that the IPO and PDO conjointly (IPO/PDO for conciseness) play a vital role in modulating the pace of global warming. It is less clear, however, how externally forced global warming may, in turn, affect the IPO/PDO. One obstacle to revealing this effect is that the conventional definitions of the IPO/PDO fail to account for the spatial heterogeneity of the background warming trend, which causes the IPO/PDO to be conflated with the warming trend, especially for the twenty-first-century simulation when the forced change is likely to be more dominant. Using a large-ensemble simulation in the Community Earth System Model, version 1 (CESM1), it is shown here that a better practice of detrending prior to EOF analysis is to remove the local and nonlinear trend, defined as the ensemble-mean time series at each grid box (or simply as the quadratic fit of the local time series if such an ensemble is not available). The revised IPO/PDO index is purely indicative of internal decadal variability. In the twenty-first-century warmer climate, the IPO/PDO has a weaker amplitude in space, a higher frequency in time, and a muted impact on global and North American temperature and rainfall.

54 ENVIRONMENTAL SCIENCES↗

SU-F-J-133: Adaptive Radiation Therapy with a Four-Dimensional Dose Calculation Algorithm That Optimizes Dose Distribution Considering Breathing Motion

Purpose: To model patient motion and produce four-dimensional (4D) optimized dose distributions that consider motion-artifacts in the dose calculation during the treatment planning process. Methods: An algorithm for dose calculation is developed where patient motion is considered in dose calculation at the stage of the treatment planning. First, optimal dose distributions are calculated for the stationary target volume where the dose distributions are optimized considering intensity-modulated radiation therapy (IMRT). Second, a convolution-kernel is produced from the best-fitting curve which matches the motion trajectory of the patient. Third, the motion kernel is deconvolved with the initial dose distribution optimized for the stationary target to produce a dose distribution that is optimized in four-dimensions. This algorithm is tested with measured doses using a mobile phantom that moves with controlled motion patterns. Results: A motion-optimized dose distribution is obtained from the initial dose distribution of the stationary target by deconvolution with the motion-kernel of the mobile target. This motion-optimized dose distribution is equivalent to that optimized for the stationary target using IMRT. The motion-optimized and measured dose distributions are tested with the gamma index with a passing rate of >95% considering 3% dose-difference and 3mm distance-to-agreement. If the dose delivery per beam takes place over several respiratory cycles, then the spread-out of the dose distributions is only dependent on the motion amplitude and not affected by motion frequency and phase. This algorithm is limited to motion amplitudes that are smaller than the length of the target along the direction of motion. Conclusion: An algorithm is developed to optimize dose in 4D. Besides IMRT that provides optimal dose coverage for a stationary target, it extends dose optimization to 4D considering target motion. This algorithm provides alternative to motion management techniques such as beam-gating or breath-holding and has potential applications in adaptive radiation therapy.

60 APPLIED LIFE SCIENCES↗

Multiple magnetic droplet soliton modes

Droplet solitons are large amplitude localized spin-wave excitations that can be created in magnetic thin films with uniaxial anisotropy by a spin-polarized current flowing through an electrical nanocontact. Here, we report a low-temperature (4 K) experimental study that shows there are multiple and, under certain conditions, combinations of droplet modes, each mode with a distinct high-frequency spin precession (tens of gigahertz). Low-frequency (≲1GHz) voltage noise is used to assess the stability of droplet modes. Furthermore, it is found that droplets are stable only in a limited range of applied field and current, typically near the current and field at which they nucleate, in agreement with recent predictions. Applied fields in the film plane favor multiple droplet modes, whereas fields perpendicular to the film plane tend to stabilize a single droplet mode. Furthermore, micromagnetic simulations are used to show that spatial variation in the energy landscape in the nanocontact region (e.g., spatial variation of magnetic anisotropy or magnetic field) can lead to quantized droplet modes and low-frequency mode modulation, characteristics observed in our experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

WE-EF-BRA-03: Catheter- Free Ablation with External Photon Radiation: Treatment Planning, Delivery Considerations, and Correlation of Effects with Delivered Dose

Purpose: To plan, target, and calculate delivered dose in atrioventricular node (AVN) ablation with volume-modulated arc therapy (VMAT) in an intact porcine model. Methods: Seven pigs underwent AVN irradiation, with prescription doses ranging between 25 and 55Gy in a single fraction. Cardiac CT scans were acquired at expiration. Two physicians contoured AVN targets on 10 phases, providing estimates of target motion and inter-physician variability. Treatment planning was conducted on a static phase-averaged CT. The volume designated to receive prescription dose covered the full extent of AVN cardiac motion, expanded by 4mm for setup uncertainty. Optimization limited doses to risk structures according to single-fraction tumor treatment protocols. Orthogonal kV images were used to align bony anatomy at time of treatment. Localization was further refined with respiratory-gated cone-beam CT, and range of cardiac motion was verified under fluoroscopy. Beam delivery was respiratory-gated for expiration with a mean efficiency of 60%. Deformable registration of the 10 cardiac CT phases was used to calculate actual delivered dose for comparison to electro-anatomical and visually evident lesions. Results: The mean [minimum,maximum] amplitude of AVN cardiac motion was LR 2.9 [1.7,3.9]mm, AP 6.6 [4.4,10.4]mm, and SI 5.6 [2.0,9.9]mm. Incorporating cardiac motion into the dose calculation showed the volume receiving full dose was 40–80% of the volume indicated on the static planning image, although the contoured AVN target received full dose in all animals. Initial results suggest the dimensions of the electro-anatomical lesion are correlated with the 40Gy isodose volume. Conclusion: Image-guidance techniques allow for accurate and precise delivery of VMAT for catheter-free arrhythmia ablation. An arsenal of advanced radiation planning, dose optimization, and image-guided delivery techniques was employed to assess and mitigate effects of cardiac and respiratory motion. Feasibility of delivery to the pulmonary veins and left ventricular myocardium will be investigated in future studies. D. Packer Disclosures: Abiomed, Biosense Webster, Inc., Boston Scientific Corp., CardioFocus, Inc., Johnson and Johnson, Excerpta Medica, Ortho-McNeil-Jannsen, Sanofi Aventis, CardioInsight Technologies, InfoBionic, SIEMENS, Medtronic, Inc., CardioDx, Inc., CardioInsight Technologies, FoxP2 Medica, Mediasphere Medical, Wiley-Blackwell, St. Jude Medical, Endosense, Thermedical, EP Advocate LLC, Hansen Medical, American Heart Association, EpiEP, NIH.

60 APPLIED LIFE SCIENCES↗

Time-average TV holography for vibration fringe analysis

Time-average TV holography is widely used method for vibration measurement. The method generates speckle correlation time-averaged J0 fringes that can be used for full-field qualitative visualization of mode shapes at resonant frequencies of an object under harmonic excitation. In order to map the amplitudes of vibration, quantitative evaluation of the time-averaged fringe pattern is desired. A quantitative evaluation procedure based on the phase-shifting technique used in two beam interferometry has also been adopted for this application with some modification. The existing procedure requires a large number of frames to be recorded for implementation. We propose a procedure that will reduce the number of frames required for the analysis. The TV holographic system used and the experimental results obtained with it on an edge-clamped, sinusoidally excited square aluminium plate sample are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of action thresholds for electromagnetic tracking system-guided hypofractionated prostate radiotherapy using volumetric modulated arc therapy

Purpose: Hypofractionated prostate radiotherapy may benefit from both volumetric modulated arc therapy (VMAT) due to shortened treatment time and intrafraction real-time monitoring provided by implanted radiofrequency(RF) transponders. The authors investigate dosimetrically driven action thresholds (whether treatment needs to be interrupted and patient repositioned) in VMAT treatment with electromagnetic (EM) tracking. Methods: VMAT plans for five patients are generated for prescription doses of 32.5 and 42.5 Gy in five fractions. Planning target volume (PTV) encloses the clinical target volume (CTV) with a 3 mm margin at the prostate-rectal interface and 5 mm elsewhere. The VMAT delivery is modeled using 180 equi-spaced static beams. Intrafraction prostate motion is simulated in the plan by displacing the beam isocenter at each beam assuming rigid organ motion according to a previously recorded trajectory of the transponder centroid. The cumulative dose delivered in each fraction is summed over all beams. Two sets of 57 prostate motion trajectories were randomly selected to form a learning and a testing dataset. Dosimetric end points including CTV D95%, rectum wall D1cc, bladder wall D1cc, and urethra Dmax, are analyzed against motion characteristics including the maximum amplitude of the anterior-posterior (AP), superior-inferior (SI), and left-right components. Action thresholds are triggered when intrafraction motion causes any violations of dose constraints to target and organs at risk (OAR), so that treatment is interrupted and patient is repositioned. Results: Intrafraction motion has a little effect on CTV D95%, indicating PTV margins are adequate. Tight posterior and inferior action thresholds around 1 mm need to be set in a patient specific manner to spare organs at risk, especially when the prescription dose is 42.5 Gy. Advantages of setting patient specific action thresholds are to reduce false positive alarms by 25% when prescription dose is low, and increase the sensitivity of detecting dose limits violations by 30% when prescription dose is high, compared to a generic 2 mm action box. The sensitivity and specificity calculated from the testing dataset are consistent to the learning set, which indicates that the patient specific approach is reliable and reproducible within the scope of the prostate database. Conclusions: This work introduces a formalism for ensuring a VMAT delivery meets the most clinically important dose requirements by using patient specific and dosimetric-driven action thresholds to hold the beam and reposition the patient when necessary. Such methods can provide improved sensitivity and specificity compared to conventional methods, which assume directionally symmetric action thresholds.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling fast ion losses due to tearing and internal kink perturbations in MAST-U

Fast ion (FI) loss properties in the presence of tearing mode and internal kink perturbations are numerically investigated for discharges in the MAST-U spherical tokamak, utilizing the MARS-F magnetohydrodynamic stability code and the REORBIT test particle guiding-center orbit-following module. Here, tracing about 100 000 particle markers sampled from the equilibrium distribution of the neutral-beam injection induced FIs, it is found that about 10% out of the total strike the limiting surface (including the divertor surface) in MAST-U discharge 46943, assuming a maximum perturbation of 100 G inside the plasma (corresponding to ~6 G at the Mirnov probe location at the outboard mid-plane). Detailed particle tracing, assuming a uniform initial distribution in the 2D phase space (at given radial locations), reveals that initially counter-current FIs launched near the plasma edge are subject to significant prompt losses, while almost all initially co-current ions remain well confined at the assumed perturbation level. Most lost FIs strike the lower-half of the limiting surface. Finite gyro-radius effects prevent lost ions from striking the top-outer corner of the super-X divertor chamber. A scan of the perturbation level (based on discharge 45163) reveals, not surprisingly, an approximately linear scaling of the particle loss fraction (for counter-current FIs) with respect to the perturbation amplitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The high current, fast, 100ns, Linear Transformer Driver (LTD) developmental project at Sandia Laboratories and HCEI.

Sandia National Laboratories, Albuquerque, N.M., USA, in collaboration with the High Current Electronic Institute (HCEI), Tomsk, Russia, is developing a new paradigm in pulsed power technology: the Linear Transformer Driver (LTD) technology. This technological approach can provide very compact devices that can deliver very fast high current and high voltage pulses straight out of the cavity with out any complicated pulse forming and pulse compression network. Through multistage inductively insulated voltage adders, the output pulse, increased in voltage amplitude, can be applied directly to the load. The load may be a vacuum electron diode, a z-pinch wire array, a gas puff, a liner, an isentropic compression load (ICE) to study material behavior under very high magnetic fields, or a fusion energy (IFE) target. This is because the output pulse rise time and width can be easily tailored to the specific application needs. In this paper we briefly summarize the developmental work done in Sandia and HCEI during the last few years, and describe our new MYKONOS Sandia High Current LTD Laboratory. An extensive evaluation of the LTD technology is being performed at SNL and the High Current Electronic Institute (HCEI) in Tomsk Russia. Two types of High Current LTD cavities (LTD I-II, and 1-MA LTD) were constructed and tested individually and in a voltage adder configuration (1-MA cavity only). All cavities performed remarkably well and the experimental results are in full agreement with analytical and numerical calculation predictions. A two-cavity voltage adder is been assembled and currently undergoes evaluation. This is the first step towards the completion of the 10-cavity, 1-TW module. This MYKONOS voltage adder will be the first ever IVA built with a transmission line insulated with deionized water. The LTD II cavity renamed LTD III will serve as a test bed for evaluating a number of different types of switches, resistors, alternative capacitor configurations, cores and other cavity components. Experimental results will be presented at the Conference and in future publications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimentally studied dynamic dose interplay does not meaningfully affect target dose in VMAT SBRT lung treatments

Purpose: The effects of respiratory motion on the tumor dose can be divided into the gradient and interplay effects. While the interplay effect is likely to average out over a large number of fractions, it may play a role in hypofractionated [stereotactic body radiation therapy (SBRT)] treatments. This subject has been extensively studied for intensity modulated radiation therapy but less so for volumetric modulated arc therapy (VMAT), particularly in application to hypofractionated regimens. Also, no experimental study has provided full four-dimensional (4D) dose reconstruction in this scenario. The authors demonstrate how a recently described motion perturbation method, with full 4D dose reconstruction, is applied to describe the gradient and interplay effects during VMAT lung SBRT treatments.Methods: VMAT dose delivered to a moving target in a patient can be reconstructed by applying perturbations to the treatment planning system-calculated static 3D dose. Ten SBRT patients treated with 6 MV VMAT beams in five fractions were selected. The target motion (motion kernel) was approximated by 3D rigid body translation, with the tumor centroids defined on the ten phases of the 4DCT. The motion was assumed to be periodic, with the period T being an average from the empirical 4DCT respiratory trace. The real observed tumor motion (total displacement ≤8 mm) was evaluated first. Then, the motion range was artificially increased to 2 or 3 cm. Finally, T was increased to 60 s. While not realistic, making T comparable to the delivery time elucidates if the interplay effect can be observed. For a single fraction, the authors quantified the interplay effect as the maximum difference in the target dosimetric indices, most importantly the near-minimum dose (D{sub 99%}), between all possible starting phases. For the three- and five-fractions, statistical simulations were performed when substantial interplay was found.Results: For the motion amplitudes and periods obtained from the 4DCT, the interplay effect is negligible (<0.2%). It is also small (0.9% average, 2.2% maximum) when the target excursion increased to 2–3 cm. Only with large motion and increased period (60 s) was a significant interplay effect observed, with D{sub 99%} ranging from 16% low to 17% high. The interplay effect was statistically significantly lower for the three- and five-fraction statistical simulations. Overall, the gradient effect dominates the clinical situation.Conclusions: A novel method was used to reconstruct the volumetric dose to a moving tumor during lung SBRT VMAT deliveries. With the studied planning and treatment technique for realistic motion periods, regardless of the amplitude, the interplay has nearly no impact on the near-minimum dose. The interplay effect was observed, for study purposes only, with the period comparable to the VMAT delivery time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toroidal modeling of runaway electron loss due to 3D fields in ITER

Mitigation of runaway electrons (REs) by three-dimensional (3D) magnetic field perturbations is numerically investigated for the ITER 15 MA baseline D–T scenario, utilizing the MARS-F code (Liu et al Phys. Plasmas 7 3681) with a drift orbit test particle tracing module. Considered are two types of 3D fields: the n = 3 (n is the toroidal mode number) resonant magnetic perturbation (RMP) utilized for the purpose of controlling the edge localized modes in ITER, and perturbations generated by the n = 1 magneto-hydrodynamic (MHD) instabilities in a post-disruption plasma. The RMP field, applied to a pre-disruption plasma, is found to be moderately effective in mitigating the RE seeds in ITER when vacuum field model is assumed. Up to ~40% loss fraction is possible at 90 kA-turn coil current. The mitigation efficiency is however substantially reduced, down to less than 5%, when the plasma response is taken into account. This is due to strong screening of the resonant magnetic field components by the plasma response resulting in much less field line stochasticity. On the other hand, the MARS-F modeling, based on the DINA-simulated post-disruption equilibria, shows that the n = 1 resistive kink instabilities develop in these plasmas, as the edge safety factor qa evolves and drops below integer numbers. RE mitigation by these MHD instabilities is sensitive to the eigenmode structure. The best mitigation is achieved as q a drops below 3, when a global kink instability occurs that encompasses both internal and external components. This global instability is found to be capable of mitigating over 80% MeV-level passing RE orbits at a field perturbation |δB|/B 0 that is comparable to that observed in DIII-D experiments, and full mitigation if the perturbation amplitude is doubled. The 'wetted' area on the ITER limiting surface, due to MHD instability induced RE loss, generally increases with the perturbation amplitude (together with increasing loss fraction). At the highest perturbation level assumed in this study, the wetted area reaches ~60% of the total limiting surface area. Lastly, the lost RE orbits mainly strike the outer divertor region of the limiting surface, with some fraction also hitting a wide area along the inboard side of the surface.

3D fields↗

SU-F-BRD-01: A Novel 4D Robust Optimization Mitigates Interplay Effect in Intensity-Modulated Proton Therapy for Lung Cancer

Purpose: To compare the impact of interplay effect on 3D and 4D robustly optimized intensity-modulated proton therapy (IMPT) plans to treat lung cancer. Methods: Two IMPT plans were created for 11 non-small-cell-lung-cancer cases with 6–14 mm spots. 3D robust optimization generated plans on average CTs with the internal gross tumor volume density overridden to deliver 66 CGyE in 33 fractions to the internal target volume (ITV). 4D robust optimization generated plans on 4D CTs with the delivery of prescribed dose to the clinical target volume (CTV). In 4D optimization, the CTV of individual 4D CT phases received non-uniform doses to achieve a uniform cumulative dose. Dose evaluation software was developed to model time-dependent spot delivery to incorporate interplay effect with randomized starting phases of each field per fraction. Patient anatomy voxels were mapped from phase to phase via deformable image registration to score doses. Indices from dose-volume histograms were used to compare target coverage, dose homogeneity, and normal-tissue sparing. DVH indices were compared using Wilcoxon test. Results: Given the presence of interplay effect, 4D robust optimization produced IMPT plans with better target coverage and homogeneity, but slightly worse normal tissue sparing compared to 3D robust optimization (unit: Gy) [D95% ITV: 63.5 vs 62.0 (p=0.014), D5% - D95% ITV: 6.2 vs 7.3 (p=0.37), D1% spinal cord: 29.0 vs 29.5 (p=0.52), Dmean total lung: 14.8 vs 14.5 (p=0.12), D33% esophagus: 33.6 vs 33.1 (p=0.28)]. The improvement of target coverage (D95%,4D – D95%,3D) was related to the ratio RMA3/(TVx10−4), with RMA and TV being respiratory motion amplitude (RMA) and tumor volume (TV), respectively. Peak benefit was observed at ratios between 2 and 10. This corresponds to 125 – 625 cm3 TV with 0.5-cm RMA. Conclusion: 4D optimization produced more interplay-effect-resistant plans compared to 3D optimization. It is most effective when respiratory motion is modest compared to TV. NIH/NCI K25CA168984; Eagles Cancer Research Career Development; The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research; Mayo ASU Seed Grant; The Kemper Marley Foundation.

60 APPLIED LIFE SCIENCES↗

Tutorial: Reactive high power impulse magnetron sputtering (R-HiPIMS)

High Power Impulse Magnetron Sputtering (HiPIMS) is a coating technology that combines magnetron sputtering with pulsed power concepts. Furthermore, by applying power in pulses of high amplitude and a relatively low duty cycle, large fractions of sputtered atoms and near-target gases are ionized. In contrast to conventional magnetron sputtering, HiPIMS is characterized by self-sputtering or repeated gas recycling for high and low sputter yield materials, respectively, and both for most intermediate materials. The dense plasma in front of the target has the dual function of sustaining the discharge and providing plasma-assistance to film growth, affecting the microstructure of growing films. Many technologically interesting thin films are compound films, which are composed of one or more metals and a reactive gas, most often oxygen or nitrogen. When reactive gas is added, non-trivial consequences arise for the system because the target may become “poisoned,” i.e., a compound layer forms on the target surface affecting the sputtering yield and the yield of secondary electron emission and thereby all other parameters. It is emphasized that the target state depends not only on the reactive gas' partial pressure (balanced via gas flow and pumping) but also on the ion flux to the target, which can be controlled by pulse parameters. This is a critical technological opportunity for reactive HiPIMS (R-HiPIMS). The scope of this tutorial is focused on plasma processes and mechanisms of operation and only briefly touches upon film properties. It introduces R-HiPIMS in a systematic, step-by-step approach by covering sputtering, magnetron sputtering, reactive magnetron sputtering, pulsed reactive magnetron sputtering, HiPIMS, and finally R-HiPIMS. The tutorial is concluded by considering variations of R-HiPIMS known as modulated pulsed power magnetron sputtering and deep-oscillation magnetron sputtering and combinations of R-HiPIMS with superimposed dc magnetron sputtering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cross-polarization systematics due to Mizuguchi-Dragone condition breaking by a continuously rotating half-wave plate at prime focus in the Huan Tran telescope

Polarization modulation using a continuously rotating half-wave plate (HWP) is a promising technique to reduce both low-frequency noise and instrumental systematics for Cosmic Microwave Background (CMB) polarization measurements targeting in ationary B-modes. Although a HWP is best placed sky-side of the telescope optics in order to minimize systematics, >0.5 meter aperture class telescopes must put the HWP elsewhere in the optics chain due to current fabrication limitations in the available HWP size. Polarbear is a ground-based CMB experiment installed on the 2.5m aperture off-axis Gregorian-Dragone type Huan Tran Telescope (HTT) designed to satisfy the Mizuguchi-Dragone condition. Polarbear-2 is a receiver that will be installed on a second HTT in 2018. Polarbear-2 is designed to have a larger field-of-view (FOV) and vastly increased sensitivity to the polarized CMB compared to Polarbear. From the third season of observations, Polarbear has installed a continuously rotating HWP at the spatially localized focus plane between the HTT primary and secondary re ectors which is an optimal location for minimizing the HWP diameter. The HWP's polarization angle re ection with respect to its birefringent axis will theoretically break the Mizuguchi-Dragone condition when placed between the two reflectors and increase cross-polarization systematics. In this study, we analyze how the Mizuguchi-Dragone condition is violated due to a HWP at this location. We then estimate the crosspolarization systematics of the HTT using physical optics simulations. We model an ideal HWP at various angles to estimate the effects of demodulation. We evaluate the increased cross-polarization as the Stokes Q-U mixing term using the Mueller Matrix formalism. It is calculated that this term creates a varying dipole beam pattern whose amplitude ranges from 1% at the center to 10% at the edge FOV pixels for Polarbear and potentially up to 20% for Polarbear-2. We also estimate the leakage of the E-mode into the B-mode angular power spectrum measurements due to this cross-polarization. We show that the cross-polarization systematic error leakage is sufficiently lower than the Polarbear-2 statistical uncertainty thanks to mitigations such as focal plane averaging and sky rotation. Currently for Polarbear-2 we are planning to place the HWP at Gregorian focus, but keeping the HWP at prime focus as a back-up solution in case that there are unforeseen telescope spatial and HWP material size constraints. Through this study we find that even though a HWP between the two reflectors will violate the Mizuguchi-Dragone condition, this HWP at prime focus will still have sufficiently low cross-polarization for Polarbear-2. The prime focus HWP is a potential configuration that can be applied to similar off-axis Gregorian-Dragone telescopes in order to minimize the required HWP diameter.

Takakura, Satoru↗