Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators,Other”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Spatiotemporal processing of linear acceleration: primary afferent and central vestibular neuron responses

Spatiotemporal convergence and two-dimensional (2-D) neural tuning have been proposed as a major neural mechanism in the signal processing of linear acceleration. To examine this hypothesis, we studied the firing properties of primary otolith afferents and central otolith neurons that respond exclusively to horizontal linear accelerations of the head (0.16-10 Hz) in alert rhesus monkeys. Unlike primary afferents, the majority of central otolith neurons exhibited 2-D spatial tuning to linear acceleration. As a result, central otolith dynamics vary as a function of movement direction. During movement along the maximum sensitivity direction, the dynamics of all central otolith neurons differed significantly from those observed for the primary afferent population. Specifically at low frequencies (</=0.5 Hz), the firing rate of the majority of central otolith neurons peaked in phase with linear velocity, in contrast to primary afferents that peaked in phase with linear acceleration. At least three different groups of central response dynamics were described according to the properties observed for motion along the maximum sensitivity direction. "High-pass" neurons exhibited increasing gains and phase values as a function of frequency. "Flat" neurons were characterized by relatively flat gains and constant phase lags (approximately 20-55 degrees ). A few neurons ("low-pass") were characterized by decreasing gain and phase as a function of frequency. The response dynamics of central otolith neurons suggest that the approximately 90 degrees phase lags observed at low frequencies are not the result of a neural integration but rather the effect of nonminimum phase behavior, which could arise at least partly through spatiotemporal convergence. Neither afferent nor central otolith neurons discriminated between gravitational and inertial components of linear acceleration. Thus response sensitivity was indistinguishable during 0.5-Hz pitch oscillations and fore-aft movements. The fact that otolith-only central neurons with "high-pass" filter properties exhibit semicircular canal-like dynamics during head tilts might have important consequences for the conclusions of previous studies of sensory convergence and sensorimotor transformations in central vestibular neurons.

NASA Discipline Neuroscience↗

Horizontal vestibuloocular reflex evoked by high-acceleration rotations in the squirrel monkey. III. Responses after labyrinthectomy

The horizontal angular vestibuloocular reflex (VOR) evoked by high-frequency, high-acceleration rotations was studied in four squirrel monkeys after unilateral labyrinthectomy. Spontaneous nystagmus was measured at the beginning and end of each testing session. During the period that animals were kept in darkness (4 days), the nystagmus at each of these times measured approximately 20 degrees /s. Within 18-24 h after return to the light, the nystagmus (measured in darkness) decreased to 2.8 +/- 1.5 degrees /s (mean +/- SD) when recorded at the beginning but was 20.3 +/- 3.9 degrees /s at the end of the testing session. The latency of the VOR measured from responses to steps of acceleration (3,000 degrees /s(2) reaching a velocity of 150 degrees /s) was 8.4 +/- 0.3 ms for responses to ipsilesional rotations and 7.7 +/- 0.4 ms for contralesional rotations. During the period that animals were kept in darkness after the labyrinthectomy, the gain of the VOR measured during the steps of acceleration was 0.67 +/- 0.12 for contralesional rotations and 0.39 +/- 0.04 for ipsilesional rotations. Within 18-24 h after return to light, the VOR gain for contralesional rotations increased to 0.87 +/- 0.08, whereas there was only a slight increase for ipsilesional rotations to 0.41 +/- 0. 06. A symmetrical increase in the gain measured at the plateau of head velocity was noted after the animals were returned to light. The VOR evoked by sinusoidal rotations of 2-15 Hz, +/-20 degrees /s, showed a better recovery of gain at lower (2-4 Hz) than at higher (6-15 Hz) frequencies. At 0.5 Hz, gain decreased symmetrically when the peak amplitude was increased from 20 to 100 degrees /s. At 10 Hz, gain was decreased for ipsilesional half-cycles and increased for contralesional half-cycles when velocity was raised from 20 to 50 degrees /s. A model incorporating linear and nonlinear pathways was used to simulate the data. Selective increases in the gain for the linear pathway accounted for the recovery in VOR gain for responses at the velocity plateau of the steps of acceleration and for the sinusoidal rotations at lower peak velocities. The increase in gain for contralesional responses to steps of acceleration and sinusoidal rotations at higher frequencies and velocities was due to an increase in the contribution of the nonlinear pathway. This pathway was driven into cutoff and therefore did not affect responses for rotations toward the lesioned side.

NASA Discipline Neuroscience↗

A Variable Energy CW Compact Accelerator for Ion Cancer Therapy

Cancer is the second-largest cause of death in the U.S. and approximately two-thirds of all cancer patients will receive radiation therapy with the majority of the radiation treatments performed using x-rays produced by electron linacs. Charged particle beam radiation therapy, both protons and light ions, however, offers advantageous physical-dose distributions over conventional photon radiotherapy, and, for particles heavier than protons, a significant biological advantage. Despite recognition of potential advantages, there is almost no research activity in this field in the U.S. due to the lack of clinical accelerator facilities offering light ion therapy in the States. In January, 2013, a joint DOE/NCI workshop was convened to address the challenges of light ion therapy [1], inviting more than 60 experts from diverse fields related to radiation therapy. This paper reports on the conclusions of the workshop, then translates the clinical requirements into accelerat or and beam-delivery technical specifications. A comparison of available or feasible accelerator technologies is compared, including a new concept for a compact, CW, and variable energy light ion accelerator currently under development. This new light ion accelerator is based on advances in nonscaling Fixed-Field Alternating gradient (FFAG) accelerator design. The new design concepts combine isochronous orbits with long (up to 4m) straight sections in a compact racetrack format allowing inner circulating orbits to be energy selected for low-loss, CW extraction, effectively eliminating the high-loss energy degrader in conventional CW cyclotron designs.

43 PARTICLE ACCELERATORS↗

Methods of Phase and Power Control in Magnetron Transmitters for Superconducting Accelerators

Various methods of phase and power control in magnetron RF sources of superconducting accelerators intended for ADS-class projects were recently developed and studied with conventional 2.45 GHz, 1 kW, CW magnetrons operating in pulsed and CW regimes. Magnetron transmitters excited by a resonant (injection-locking) phasemodulated signal can provide phase and power control with the rates required for precise stabilization of phase and amplitude of the accelerating field in Superconducting RF (SRF) cavities of the intensity-frontier accelerators. An innovative technique that can significantly increase the magnetron transmitter efficiency at the widerange power control required for superconducting accelerators was developed and verified with the 2.45 GHz magnetrons operating in CW and pulsed regimes. High efficiency magnetron transmitters of this type can significantly reduce the capital and operation costs of the ADSclass accelerator projects.

43 PARTICLE ACCELERATORS↗

Compact, high-efficiency accelerators driven by low-voltage solid-state amplifiers

A compact particle accelerator can include two or more cavities disposed along an axis of the particle accelerator, each of which is coupled to two or more drivers. The accelerator can also include a power supply coupled to the two or more drivers such that a particle beam traveling along the axis is accelerated. The power supply can be an interface with a commercial power outlet, battery power, or a combination thereof depending upon the use case. Example configurations of the accelerator include hand held or mobile devices that are capable of delivering up to and greater than a 1 MeV electron beam.

42 ENGINEERING↗

Analysis of RF high power sources for 1MW – range, 10 MeV CW industrial accelerator.

Cobalt-60 is the dominant source of ionizing radiation for sterilizing products in the $200B/year medical device industry. Security and accessibility concerns around this radioactive material - sourced from countries including Russia and China - present national security and economic risks. There is a continued national urgency to replace such high-risk sources with low-risk alternatives such as electron or x-ray beams driven by accelerators. While e-beam sources have been in use for many years, they still represent a small portion of the market. X-ray sources are becoming economical alternatives. Meeting the processing capacity required to replace Co-60 requires a step-change in the capability, efficiency, and overall operating cost of electron accelerators to make adoption feasible. The radiofrequency (RF) power that drives accelerating cavities represents significant capital and operating costs for these accelerators. For accelerator-based systems to be a viable alternative for these applications, RF systems must be economical to manufacture, deploy, and operate.

43 PARTICLE ACCELERATORS↗

DEGRADATION IN PERFORMANCE OF LANTHANUM STRONTIUM MANGANITE BASED SOLID OXIDE FUEL CELL CATHODES UNDER ACCELERATED TESTING

The performance of solid oxide fuel cells (SOFCs) with three different lanthanum strontium manganite (LSM) based cathode compositions were evaluated. All cells were yttria-stabilized zirconia (Zr0.92Y0.08O2-δ, 8YSZ) electrolyte-supported button cells, consisting of a nickel oxide – yttria-stabilized zirconia (NiO-8YSZ) anode and a cathode of 8YSZ and LSM. The three LSM compositions differed in the amount of excess Mn: Composition A was (La0.85Sr0.15)0.90MnO3±δ (10% excess Mn); Composition B was (La0.80Sr0.20)0.95MnO3±δ (5% excess Mn); and Composition C was (La0.80Sr0.20)0.98MnO3±δ (2% excess Mn). The cells were tested under conventional and accelerated conditions, where the accelerated conditions were meant to simulate the results of months of long-term testing in just 500 hours (approximately three weeks) of testing by using high operating temperature and current density. Accelerated tests showed lower degradation rates, lower continuous area specific resistance (ASR), and higher power output than conventional tests for all cathode compositions. Continuous measurements of the cells' output voltage versus time, together with periodic electrochemical impedance spectroscopy (EIS) measurements, were used to evaluate the performance of the cells in terms of ASR degradation rates (% ASR rise per kh) and power outputs. The EIS measurements also permitted a partial deconvolution of the cathode ASR from the anode ASR. Cathodes with 10% excess Mn tested under accelerated conditions had the lowest degradation rates, but the highest continuous ASR and lowest power outputs. Cathodes with 2% excess Mn tested under accelerated conditions had the lowest continuous ASR and highest power outputs; thus it was concluded that cells with the lowest amount of excess Mn cathodes performed the best.

08 HYDROGEN↗

European Strategy for Particle Physics -- Accelerator R&D Roadmap

The 2020 update of the European Strategy for Particle Physics emphasised the importance of an intensified and well-coordinated programme of accelerator R&D, supporting the design and delivery of future particle accelerators in a timely, affordable and sustainable way. This report sets out a roadmap for European accelerator R&D for the next five to ten years, covering five topical areas identified in the Strategy update. The R&D objectives include: improvement of the performance and cost-performance of magnet and radio-frequency acceleration systems; investigations of the potential of laser / plasma acceleration and energy-recovery linac techniques; and development of new concepts for muon beams and muon colliders. The goal of the roadmap is to document the collective view of the field on the next steps for the R&D programme, and to provide the evidence base to support subsequent decisions on prioritisation, resourcing and implementation.

43 PARTICLE ACCELERATORS↗

Improvements of the boundary projection acceleration technique applied to the discrete-ordinates transport solver in XYZ geometries

In this paper we discuss the latest upgrades of the Boundary Projection Acceleration (BPA) applied to the XYZ transport solver of APOLLO3, namely IDT. The acceleration method is a well-known effective technique for the speed-up of the source iterations of the discrete-ordinates method. The BPA in IDT has been improved in three aspects: the taking into account of the residue on boundary conditions as a boundary source for the acceleration problem, the extension of the method to higher order angular moments in the case of anisotropic scattering and, finally, the application of the method to the multigroup iterations for the acceleration of the fission source and k-effective. The spectrum of the method has been Fourier-analyzed to explore the effectiveness. The 3D mock-up geometry of the ZPPR is presented as final study to test the performances of the acceleration on a realistic whole-core 3D calculation. (authors)

97 MATHEMATICS AND COMPUTING↗

Towards Agentic AI on Particle Accelerators

As particle accelerators grow in complexity, traditional control methods face increasing challenges in achieving optimal performance. This paper envisions a paradigm shift: a decentralized multi-agent framework for accelerator control, powered by Large Language Models (LLMs) and distributed among autonomous agents. We present a proposition of a self-improving decentralized system where intelligent agents handle high-level tasks and communication and each agent is specialized control individual accelerator components. This approach raises some questions: What are the future applications of AI in particle accelerators? How can we implement an autonomous complex system such as a particle accelerator where agents gradually improve through experience and human feedback? What are the implications of integrating a human-in-the-loop component for labeling operational data and providing expert guidance? We show two examples, where we demonstrate viability of such architecture.

43 PARTICLE ACCELERATORS↗

A compact low-level RF control system for advanced concept compact electron linear accelerator

A compact low-level RF (LLRF) control system based on RF system-on-chip (RFSoC) technology has been designed for the Advanced Concept Compact Electron Linear-accelerator (ACCEL) program, which has challenging requirements in both RF performance and size, weight, and power consumption (SWaP). The compact LLRF solution employs the direct RF sampling technique of RFSoC, which samples the RF signals directly without any analog upconversion and downconversion. Compared with the conventional heterodyne based architecture used for the LLRF system of a linear accelerator (LINAC), the elimination of analog mixers can significantly reduce the size and weight of the system, especially with LINAC requiring a larger number of RF channels. Based on the requirements of ACCEL, a prototype LLRF platform has been developed, and the control schemes have been proposed. The prototype LLRF system demonstrated magnitude and phase fluctuation levels below 1% and 1° on the flattop of a 2 μs RF pulse. The LLRF control schemes proposed for ACCEL are implemented with a prototype hardware platform. In conclusion, this paper will introduce the new compact LLRF solution and summarize a selection of experimental test results of the prototype itself and with the accelerating structure cavities designed for ACCEL.

Liu, C. [SLAC National Accelerator Laboratory (SLA↗

Small scale electron linear accelerators for industrial applications

Linear accelerators (linacs), producing electron or X-ray radiation in the MeV range, are critical tools for industrial irradiation, medical device sterilization, food pasteurization, non-destructive testing, security, medical, and many other applications. Many of these applications require compact and flexible radiation sources. In this paper, we present new technologies for small-scale electron linear accelerators and examples of their practical implementations. Furthermore, these developments include low energy accelerators with self-shielding options and form factors, ranging from cabinet-size to hand-portable generators; medium-energy accelerators for novel radiotherapy and security applications; and high-energy 10 MeV linacs capable of reaching 20–35 kW beam power for emerging industrial and phytosanitary applications

43 PARTICLE ACCELERATORS↗

Development of an accelerator-based neutron source to prototype Mo-99 production, part I: A liquid LBE windowless target

In this article, Molybdenum-99 (Mo-99)’s decay product, technetium-99 (Tc-99 m), is one of the most critical isotopes for medical diagnostics. To provide U.S. domestic supply of Mo-99 without using high-enriched uranium (HEU), a subcritical uranium target assembly (UTA) is irradiated by an accelerator-based neutron source to create Mo-99 through fission. This study discusses the development of the accelerator-based neutron source. The high-energy electrons from the accelerator irradiate a liquid lead-bismuth eutectic (LBE) target to produce neutrons. Part I of this work focuses on numerical and experimental analysis towards the development of a liquid LBE windowless target. Unlike the existing windowless targets in literature, the current design creates a vertical free surface for a beam to irradiate. First, a hydrodynamic analysis of the LBE windowless target is performed. Simplified analytical calculations are assisted by 2D computational fluid dynamics (CFD) simulations to design the target, with the focus on eliminating recirculation zones and avoiding cavitation. With the optimized geometry, the experimental study is performed to investigate the flow hydrodynamics using liquid LBE. The experiments (1) compare pressure drop in the system to correlation predictions; (2) visualize the free surface liquid LBE flow from the beam view; (3) validate the LBE flow profile using temperature sensitive paint from the side view; and (4) validate the liquid LBE film thickness using gamma densitometer measurements. Second, the power handling capability of the designed windowless target is investigated. The divider plate in the current design is susceptible to overheating due to the thin LBE film in front. As LBE erosion and corrosion is likely to occur at an LBE velocity of 2.0 m/s and temperature above 500 °C, a power limit of 10 kW of beam power was established to prevent this corrosion from occurring, which is calculated by a Nusselt number correlation. The divider plate surface temperature at 10 kW agrees well with the 3D CFD simulation results. Part I demonstrates the fundamental physics in liquid LBE windowless target design and associated testing. A companion paper, Part II will demonstrate how to couple this windowless target into the Mo-99 production system, including an accelerator system operating under an ultra-high vacuum and the UTA cooled by water at room temperature.

43 PARTICLE ACCELERATORS↗

High Gradient Two-Beam Electron Accelerator

A high-gradient two-beam electron accelerator structure using detuned cavities is described. A self-consistent theory based on a circuit model is presented to calculate idealized acceleration gradient, transformer ratio, and efficiency for energy transfer from the drive beam to the accelerated beam. Experimental efforts are being carried out to demonstrate this acceleration concept.

43 PARTICLE ACCELERATORS↗

Prospects For and Progress Towards Laser-Driven Particle Therapy Accelerators

Recent advances in laser-ion acceleration have motivated research towards laser-driven compact accelerators for medical therapy. Realizing laser-ion acceleration for medical therapy will require adapting the medical requirements to the foreseeable laser constraints, as well as advances in laser-acceleration physics, beam manipulation and delivery, real-time dosimetry, treatment planning and translational research into a clinical setting.

43 PARTICLE ACCELERATORS↗

Dust Accelerators And Their Applications In High-Temperature Plasmas

The perennial presence of dust in high-temperature plasma and fusion devices has been firmly established. Dust inventory must be controlled, in particular in the next-generation steady-state fusion machines like ITER, as it can pose significant safety hazards and potentially interfere with fusion energy production. Although much effort has been devoted to getting rid of the dust nuisance, there are instances where a controlled use of dust can be beneficial. We have recognized a number of dust-accelerators applications in magnetic fusion, including in plasma diagnostics, in studying dust-plasma interactions, and more recently in edge localized mode (ELM)'s pacing. With the applications in mind, we will compare various acceleration methods, including electrostatic, gas-drag, and plasma-drag acceleration. We will also describe laboratory experiments and results on dust acceleration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A computational investigation of the impact of aberrated Gaussian laser pulses on electron beam properties in laser-wakefield acceleration experiments

Critical to the performance of any future accelerator based on the laser wakefield accelerator is the response of the system to perturbations from ideal. In this paper, we use particle-in-cell simulation using a modified version of the OSIRIS 2.0 framework to demonstrate that comatic optical aberrations in a nominally Gaussian laser pulse are self-corrected by the plasma response, leading to stable propagation and therefore little variation in peak energy, energy spread, or peak current of the accelerated bunch, even for serious aberrations. However, the comatic aberration does lead to enhanced transverse beam emittance in the direction of the coma. Although this may be deleterious to the performance of an accelerator, one useful outcome is that the increased oscillation amplitude of electrons in the wake structure may lead to increased synchrotron radiation emission, which would be partially polarized in the direction of coma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of beamlet deflection and its compensations in a MeV accelerator

In a five stage multi-aperture and multi-grid (MAMuG) accelerator in JAEA, beam acceleration tests are in progress toward 1 MeV, 200 A/m{sup 2} H{sup -} ion beams for ITER. The 1 MV voltage holding has been successfully demonstrated for 4,000 s with the accelerator of expanded gap length that lowered local electric field concentrations. This led to increase of the beam energy up to 900 keV-level. However, it was found that beamlets were deflected more in long gaps and direct interceptions of the deflected beamlet caused breakdowns. The beamlet deflection and its compensation methods were studied utilizing a three-dimensional multi beamlet analysis. The analysis showed that the 1 MeV beam can be compensated by a combination of the aperture offset of 0.8 mm applied in the electron suppression (ESG) and the metal bar called a field shaping plate with a thickness of 1 mm attached beneath the ESG. The paper reports these compensation methods and analytical predictions, with experimental results of the MAMuG accelerator in which those compensation techniques have been applied.

43 PARTICLE ACCELERATORS↗