Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM DYNAMICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Dynamic analysis of a buckled asymmetric piezoelectric beam for energy harvesting

A model of a buckled beam energy harvester is analyzed to determine the phenomena behind the transition between high and low power output levels. It is shown that the presence of a chaotic attractor is a sufficient condition to predict high power output, though there are relatively small areas where high output is achieved without a chaotic attractor. The chaotic attractor appears as a product of a period doubling cascade or a boundary crisis. Bifurcation diagrams provide insight into the development of the chaotic region as the input power level is varied, as well as the intermixed periodic windows.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exact dynamic responses of periodic multi-span beams under convected pressure fields

Response of a structure to a convected pressure field generated by far-field jet-noise or turbulent boundary layer is often of interest in engineering. The structure considered in present study is a periodic beam with equally rotational elastic supports. The convected pressure field is characterized by a broad frequency spectrum and a particular convection velocity. In the first order approximation, all the frequency components in the pressure spectrum are convected with the same velocity. In this paper, both finitely and infinitely long periodic beams under convected harmonic pressure are investigated. The exact harmonic responses are obtained by introducing new expressions of mode shapes for these two types of beams into the normal mode approach. Thus, both locations and values of the response peaks in the propagation bands can be precisely predicted and the important coincidence phenomenon can be investigated in exact terms. This work provides a foundation on which the study on vibration control of structure can be conducted.

Zhu, Li-Ping↗

Exact element modal analysis of beam/oscillator systems

Exact modal analysis of a beam/many-oscillator system is presented. Each oscillator consists of a discrete mass having rotational inertia, and two locally-dependent springs: one being rotational and the other, translational. A constant longitudinal force is applied to the mass, and its effect is coupled with the dynamic modes. The beam's distributed mass and other material properties, and its geometric properties, do not vary within spans bounded by the oscillators, but may vary from span to span. The classical separation-of-variables technique is used to obtain a dosedform description of the dynamic matrix, and the modal frequencies are determined as the zeros of this determinant.

Broome, Taft H., Jr.↗

An Alternative High Luminosity LHC with Flat Optics and Long-Range Beam-Beam Compensation

In the baseline scenario of the High-Luminosity LHC (HL-LHC), the geometric loss of luminosity in the two high luminosity experiments due to collisions with a large crossing angle is recovered by tilting the bunches in the interaction region with the use of crab cavities. A possible backup scenario would rely on a reduced crossing angle together with flat optics (with different horizontal and vertical $\beta^{\ast}$values) for the preservation of luminosity performance. However, the reduction of crossing angle coupled with the flat optics significantly enhances the strength of long-range beam-beam interactions. This paper discusses the possibility to mitigate the long-range beam-beam effects by current bearing wire compensators (or e-lens). We develop a new HL-LHC parameter list and analyze it in terms of integrated luminosity performance as compared to the baseline. Further, we evaluate the operational scenarios using numerical simulations of single-particle dynamics with beam-beam effects.

Fartoukh, Stephane↗

Electron-Beam-Induced Molecular Plasmon Excitation and Energy Transfer in Silver Molecular Nanowires

In this work, we investigate (1) electron-beam-induced plasmon absorption spectra of Ag molecular nanowire dimers and (2) electron-beam-induced energy transfer between two nanowires. We employ linear-response time-dependent density functional theory (TDDFT) and real-time TDDFT methods to simulate the electron-beam-induced plasmonic excitations, dynamics, and corresponding electron energy loss spectrum for small models of a single molecular nanowire with four Ag atoms and for two Ag nanowires. An array of different relative orientations of nanowires and of different initial excitation conditions resulting from applying an electron beam at different positions with respect to the Ag nanowires is investigated. The results demonstrate (1) an electron beam can induce plasmonic excitations from the molecular Ag nanowire ground state to the excited states that are both optically allowed and forbidden, (2) a tunability for selective excitations that can be controlled by the position of a focused electron beam, and (3) kinetic and dynamic behaviors of time-dependent electron-beam-induced energy transfer between two Ag molecular nanowires depend on the position of the beam source and nanowire separation distance, providing insights into the spatial dependences of plasmonic couplings in nanowire arrays.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Future Synchrotron Light Sources Based on Ultimate Storage Rings

The main purpose of this talk is to describe how far one might push the state of the art in storage ring design. The talk will start with an overview of the latest developments and advances in the design of synchrotron light sources based on the concept of an 'ultimate' storage ring. The review will establish how bright a ring based light source might be, where the frontier of technological challenges are, and what the limits of accelerator physics are. Emphasis will be given to possible improvements in accelerator design and developments in technology toward the goal of achieving an ultimate storage ring. An ultimate storage ring (USR), defined as an electron ring-based light source having an emittance in both transverse planes at the diffraction limit for the range of X-ray wavelengths of interest for a scientific community, would provide very high brightness photons having high transverse coherence that would extend the capabilities of X-ray imaging and probe techniques beyond today's performance. It would be a cost-effective, high-coherence 4th generation light source, competitive with one based on energy recovery linac (ERL) technology, serving a large number of users studying material, chemical, and biological sciences. Furthermore, because of the experience accumulated over many decades of ring operation, it would have the great advantage of stability and reliability. In this paper we consider the design of an USR having 10-pm-rad emittance. It is a tremendous challenge to design a storage ring having such an extremely low emittance, a factor of 100 smaller than those in existing light sources, especially such that it has adequate dynamic aperture and beam lifetime. In many ultra-low emittance designs, the injection acceptances are not large enough for accumulation of the electron beam, necessitating on-axis injection where stored electron bunches are completely replaced with newly injected ones. Recently, starting with the MAX-IV 7-bend achromatic cell, we have made significant progress with the design of PEP-X, a USR that would inhabit the decommissioned PEP-II tunnel at SLAC. The enlargement of the dynamic aperture is largely a result of the cancellations of the 4th-order resonances in the 3rd-order achromats and the effective use of lattice optimization programs. In this paper, we will show those cancellations of the 4th-order resonances using an analytical approach based on the exponential Lie operators and the Poisson brackets. Wherever possible, our analytical results will be compared with their numerical counterparts. Using the derived formulae, we will construct 4th-order geometric achromats and use them as modules for the lattice of the PEP-X USR, noting that only geometric terms are canceled to the 4th order.

43 PARTICLE ACCELERATORS↗

Revisiting an airgap split-optics mitigation for beam filamentation in high power lasers

We extend the split-optic approach for mitigating filamentation in a thick optical component previously proposed for small beams to conditions relevant to high-power lasers. The split-optic approach divides a thick optic into two thinner optics separated by an airgap to reduce filamentation through diffraction management. Our numerical study focuses on filamentation of a flat-top beam with intensity modulation noise sources passing through a split-optic system. The improvement in the distance to collapse in glass is shown to be potentially substantial (>30%), yet has limited increase with the airgap size, unlike the common understanding when considering a collapse of a whole beam or a sole perturbation on a beam. The improvement in the collapse distance in glass asymptotes to an upper bound value that depends mainly on the beam mean intensity and its contrast for any airgap size above some value that depends mainly on the shortest spatial periods comprising the excitation noise source. Examining the difference in the simulation results for a periodic versus a randomly generated perturbation source-term suggests that the observed effect is governed by the statistical interference dynamics of the beam while propagating through the airgap

47 OTHER INSTRUMENTATION↗

The development, testing and characterisation of a straw tracking detector and readout system for the Fermilab muon g-2 experiment

The anomalous magnetic moments of leptons can be both measured and theoretically predicted with high precision, and as such provide stringent tests of the Standard Model (SM) of particle physics. The anomalous magnetic moment of the muon, $a_\mu$, in particular offers sensitivity to new physics within the reach of current experiments. The current world’s best measurement of aμ made at the Brookhaven National Laboratory (BNL) deviates from the SM prediction by over 3σ, providing a tantalising but inconclusive hint that contributions from new physics may be present. A new $a_\mu$ experiment is currently under construction at the Fermi National Accelerator Laboratory (Fermilab), known as the Fermilab muon g-2 experiment. Due to commence in 2017, this new experiment is expected to improve the experimental measurement precision of $a_\mu$ by a factor of 4, and is seeking to confirm or reject the current discrepancy. The experiment, like its BNL predecessor, will measure the precession of the $\mu^{+}$ spin in a magnetic storage-ring. This new experiment has three straw tracking detectors used to measure the beam profile of the stored $\mu^{+}$, as well as other dynamic properties of the beam. This thesis describes the design of these detectors, and the data acquisition system and subsequent data processing systems that have been developed to read them out and make their data available for physics analysis. The performance of the straw trackers and the readout systems at a number of beam tests and test stands is presented, in addition to Monte-Carlo simulations of the trackers in the final experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dosimetric and geometric evaluation of a novel stereotactic radiotherapy device for breast cancer: The GammaPod Trade-Mark-Sign

Purpose: A dedicated stereotactic gamma irradiation device, the GammaPod Trade-Mark-Sign from Xcision Medical Systems, was developed specifically to treat small breast cancers. This study presents the first evaluation of dosimetric and geometric characteristics from the initial prototype installed at University of Maryland Radiation Oncology Department. Methods: The GammaPod Trade-Mark-Sign stereotactic radiotherapy device is an assembly of a hemi-spherical source carrier containing 36 {sup 60}Co sources, a tungsten collimator, a dynamically controlled patient support table, and the breast immobilization system which also functions as a stereotactic frame. The source carrier contains the sources in six columns spaced longitudinally at 60 Degree-Sign intervals and it rotates together with the variable-size collimator to form 36 noncoplanar, concentric arcs focused at the isocenter. The patient support table enables motion in three dimensions to position the patient tumor at the focal point of the irradiation. The table moves continuously in three cardinal dimensions during treatment to provide dynamic shaping of the dose distribution. The breast is immobilized using a breast cup applying a small negative pressure, where the immobilization cup is embedded with fiducials also functioning as the stereotactic frame for the breast. Geometric and dosimetric evaluations of the system as well as a protocol for absorbed dose calibration are provided. Dosimetric verifications of dynamically delivered patient plans are performed for seven patients using radiochromic films in hypothetical preop, postop, and target-in-target treatment scenarios. Results: Loaded with 36 {sup 60}Co sources with cumulative activity of 4320 Ci, the prototype GammaPod Trade-Mark-Sign unit delivers 5.31 Gy/min at the isocenter using the largest 2.5 cm diameter collimator. Due to the noncoplanar beam arrangement and dynamic dose shaping features, the GammaPod Trade-Mark-Sign device is found to deliver uniform doses to targets with good conformity. The spatial accuracy of the device to locate the radiation isocenter is determined to be less than 1 mm. Single shot profiles with 2.5 cm collimator are measured with radiochromic film and found to be in good agreement with respect to the Monte Carlo based calculations (congruence of FWHM less than 1 mm). Dosimetric verifications corresponding to all hypothetical treatment plans corresponding to three target scenarios for each of the seven patients demonstrated good agreement with gamma index pass rates of better than 97% (99.0%{+-} 0.7%). Conclusions: Dosimetric evaluation of the first GammaPod Trade-Mark-Sign stereotactic breast radiotherapy unit was performed and the dosimetric and spatial accuracy of this novel technology is found to be feasible with respect to clinical radiotherapy standards. The observed level of agreement between the treatment planning system calculations and dosimetric measurements has confirmed that the system can deliver highly complex treatment plans with remarkable geometric and dosimetric accuracy.

60 APPLIED LIFE SCIENCES↗

Enhanced beam-beam modeling to include longitudinal variation during weak-strong simulation

Beam-beam interactions pose substantial challenges in the design and operation of circular colliders, significantly affecting their performance. In particular, the weak-strong simulation approach is pivotal for investigating single-particle dynamics during the collider design phase. This paper evaluates the limitations of existing models in weak-strong simulations, noting that while they accurately account for energy changes due to slingshot effects, they fail to incorporate longitudinal coordinate changes ( z variation). To address this gap, we introduce two novel transformations that enhance Hirata’s original framework by including both z variation and slingshot effect-induced energy changes. Through rigorous mathematical analysis and extensive weak-strong simulation studies, we validate the efficacy of these enhancements in achieving a more precise simulation of beam-beam interactions. Our results reveal that although z variation constitutes a higher-order effect and does not substantially affect the emittance growth rate within the specific design parameters of the Electron-Ion Collider, the refined model offers improved accuracy, particularly in scenarios involving the interaction between beam-beam effects and other random diffusion processes, as well as in simulations incorporating realistic lattice models. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advanced Modeling of Beam Physics and Performance Optimization for Nuclear Physics Colliders

High energy colliders provide a critical tool in nuclear physics study by probing the fundamental structure and dynamics of matter. To maximize the potential of scientific discovery in nuclear physics study, it is important to optimize the parameters of these colliders to attain the best performance. The performance of a collider is typically measured by its integrated luminosity of colliding beams since the probability of a new event is proportional to the integrated luminosity. However, the achievable luminosity is limited by the electromagnetic interactions (beam-beam effects) of two colliding beams at higher energy, and the interplay between the space-charge effects and the beam-beam effects at lower energy. To achieve the best performance of a collider means to attain the highest luminosity of the collider with optimized collider parameters. Optimizing the collider’s machine parameters is both computationally and experimentally expensive. A fast and robust computational framework including beam-beam and space-charge effects will be critical to attaining the best performance of the collider. In this project, we will study the beam dynamics challenges, specifically the interplay of the space-charge and the beam-beam effects, and the machine tuning models for maximizing the performance of RHIC experiments. We will develop an advanced modeling framework based on first-principles physical simulations, lattice models and the state-of-the-art machine learning methods and apply this framework to performance improvement of the RHIC in operation. We will build data manipulation packages to connect the simulation data and the experimental data with the framework, develop a self-consistent hybrid model of space-charge and beam-beam effects, study underlying physics mechanisms, build surrogate models using the labeled data, integrate the models into the advanced modeling framework, and apply the framework to RHIC luminosity (STAR and sPHENIX) optimization. The success of this project would substantially improve the performance of existing and future colliders and increase the opportunity for scientific discovery.

43 PARTICLE ACCELERATORS↗

WE-DE-BRA-11: A Study of Motion Tracking Accuracy of Robotic Radiosurgery Using a Novel CCD Camera Based End-To-End Test System

Purpose: A novel end-to-end test system using a CCD camera and a scintillator based phantom (XRV-124, Logos Systems Int’l) capable of measuring the beam-by-beam delivery accuracy of Robotic Radiosurgery (CyberKnife) was developed and reported in our previous work. This work investigates its application in assessing the motion tracking (Synchrony) accuracy for CyberKnife. Methods: A QA plan with Anterior and Lateral beams (with 4 different collimator sizes) was created (Multiplan v5.3) for the XRV-124 phantom. The phantom was placed on a motion platform (superior and inferior movement), and the plans were delivered on the CyberKnife M6 system using four motion patterns: static, Sine- wave, Sine with 15° phase shift, and a patient breathing pattern composed of 2cm maximum motion with 4 second breathing cycle. Under integral recording mode, the time-averaged beam vectors (X, Y, Z) were measured by the phantom and compared with static delivery. In dynamic recording mode, the beam spots were recorded at a rate of 10 frames/second. The beam vector deviation from average position was evaluated against the various breathing patterns. Results: The average beam position of the six deliveries with no motion and three deliveries with Synchrony tracking on ideal motion (sinewave without phase shift) all agree within −0.03±0.00 mm, 0.10±0.04, and 0.04±0.03 in the X, Y, and X directions. Radiation beam width (FWHM) variations are within ±0.03 mm. Dynamic video record showed submillimeter tracking stability for both regular and irregular breathing pattern; however the tracking error up to 3.5 mm was observed when a 15 degree phase shift was introduced. Conclusion: The XRV-124 system is able to provide 3D and 4D targeting accuracy for CyberKnife delivery with Synchrony. The experimental results showed sub-millimeter delivery in phantom with excellent correlation in target to breathing motion. The accuracy was degraded when irregular motion and phase shift was introduced.

60 APPLIED LIFE SCIENCES↗

Phase-space moment-equation model of highly relativistic electron-beams in plasma-wakefield accelerators

We formulate a new procedure for modelling the transverse dynamics of relativistic electron beams with significant energy spread when injected into plasma-based accelerators operated in the blow-out regime. Quantities of physical interest, such as the emittance, are furnished directly from solution of phase space moment equations formed from the relativistic Vlasov equation. The moment equations are closed by an Ansatz, and solved analytically for prescribed wakefields. The accuracy of the analytic formulas is established by benchmarking against the results of a semi-analytic/numerical procedure which is described within the scope of this work, and results from a simulation with the 3D quasi-static PIC code HiPACE.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiation defect dynamics in 3 C -, 4 H -, and 6 H -SiC studied by pulsed ion beams

Radiation damage behavior of SiC depends on its lattice structure. Here, we use a pulsed-ion-beam method to study defect interaction dynamics in 6H-SiC and damage buildup in 4H- and 6H-SiC irradiated at 100 °C with 500 keV Ar ions. These results are compared with previously reported data for Ar-ion-irradiated 3C- and 4H-SiC. We find that, for these irradiation conditions, damage buildup in 3C- and 6H-SiC is statistically indistinguishable and is significantly more efficient than in 4H-SiC. Within a stimulated amorphization model, 4H-SiC is described by a reduced amorphization cross-section constant, while the point defect cluster production cross-section is the same (within experimental errors) for the three polytypes studied. Moreover, 4H-SiC exhibits slower defect relaxation dynamics than 3C- and 6H-SiC. These results clearly demonstrate the importance of the lattice structure in damage buildup and defect interaction dynamics in SiC.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗