At least 1,225 records · Page 68

SU-E-T-585: Commissioning of Electron Monte Carlo in Eclipse Treatment Planning System for TrueBeam

Purpose: To commission electron Monte Carlo (eMC) algorithm in Eclipse Treatment Planning System (TPS) for TrueBeam Linacs, including the evaluation of dose calculation accuracy for small fields and oblique beams and comparison with the existing eMC model for Clinacs. Methods: Electron beam percent-depth-dose (PDDs) and profiles with and without applicators, as well as output factors, were measured from two Varian TrueBeam machines. Measured data were compared against the Varian TrueBeam Representative Beam Data (VTBRBD). The selected data set was transferred into Eclipse for beam configuration. Dose calculation accuracy from eMC was evaluated for open fields, small cut-out fields, and oblique beams at different incident angles. The TrueBeam data was compared to the existing Clinac data and eMC model to evaluate the differences among Linac types. Results: Our measured data indicated that electron beam PDDs from our TrueBeam machines are well matched to those from our Varian Clinac machines, but in-air profiles, cone factors and open-filed output factors are significantly different. The data from our two TrueBeam machines were well represented by the VTBRBD. Variations of TrueBeam PDDs and profiles were within the 2% /2mm criteria for all energies, and the output factors for fields with and without applicators all agree within 2%. Obliquity factor for two clinically relevant applicator sizes (10×10 and 15×15 cm{sup 2}) and three oblique angles (15, 30, and 45 degree) were measured for nominal R100, R90, and R80 of each electron beam energy. Comparisons of calculations using eMC of obliquity factors and cut-out factors versus measurements will be presented. Conclusion: eMC algorithm in Eclipse TPS can be configured using the VTBRBD. Significant differences between TrueBeam and Clinacs were found in in-air profiles and open field output factors. The accuracy of the eMC algorithm was evaluated for a wide range of cut-out factors and oblique incidence.

07 ISOTOPE AND RADIATION SOURCES↗

Production of baryon resonances in {pi}{sup -}+ {sup 12}C interactions at 40 GeV/c

In conditions of 4{pi}-geometry, the production of {delta}{sup ++} and {delta}{sup 0} resonances in {pi}{sup -}+ {sup 12}C interactions at 40 GeV/c was investigated for the first time. The masses and widths of resonances were obtained from an analysis of the experimental and background invariant mass distributions of p{pi}{sup {+-}} pairs. The fractions of charged pions coming from {delta}{sup ++} and {delta}{sup 0} decay as well as the inclusive cross-section of {delta}{sup ++} and {delta}{sup 0} production were determined. The results obtained were compared to the recent results on {delta}(1232) production in {sup 4}He +C and C+C collisions at 4.2 GeV/c per nucleon, and Ni+Ni and Au+Au collisions at energies between 1 and 2A GeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EBT GAFCHROMIC{sup TM} film dosimetry in compensator-based intensity modulated radiation therapy

The electron benefit transfer (EBT) GAFCHROMIC films possess a number of features making them appropriate for high-quality dosimetry in intensity-modulated radiation therapy (IMRT). Compensators to deliver IMRT are known to change the beam-energy spectrum as well as to produce scattered photons and to contaminate electrons; therefore, the accuracy and validity of EBT-film dosimetry in compensator-based IMRT should be investigated. Percentage-depth doses and lateral-beam profiles were measured using EBT films in perpendicular orientation with respect to 6 and 18 MV photon beam energies for: (1) different thicknesses of cerrobend slab (open, 1.0, 2.0, 4.0, and 6.0 cm), field sizes (5×5, 10×10, and 20×20 cm{sup 2}), and measurement depths (D{sub max}, 5.0 and 10.0 cm); and (2) step-wedged compensator in a solid phantom. To verify results, same measurements were implemented using a 0.125 cm{sup 3} ionization chamber in a water phantom and also in Monte Carlo simulations using the Monte Carlo N-particle radiation transport computer code. The mean energy of photons was increased due to beam hardening in comparison with open fields at both 6 and 18 MV energies. For a 20×20 cm{sup 2} field size of a 6 MV photon beam and a 6.0 cm thick block, the surface dose decreased by about 12% and percentage-depth doses increased up to 3% at 30.0 cm depth, due to the beam-hardening effect induced by the block. In contrast, at 18 MV, the surface dose increased by about 8% and depth dose reduced by 3% at 30.0 cm depth. The penumbral widths (80% to 20%) increase with block thickness, field size, and beam energy. The EBT film results were in good agreement with the ionization chamber dose profiles and Monte Carlo N-particle radiation transport computer code simulation behind the step-wedged compensator. Also, there was a good agreement between the EBT-film and the treatment-planning results on the anthropomorphic phantom. The EBT films can be accurately used as a 2D dosimeter for dose verification and quality assurance of compensator-based C-IMRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Numerical simulation of the generation of electrostatic turbulence in the magnetotail

A two-dimensional plasma model is used to investigate the development of electrostatic turbulence in a magnetized plasma from plasma instabilities. The simulation consists of following the motion of 100,000 ions in their self-consistent electrostatic field. The electrons are treated as a constant neutralizing background. The instabilities modeled are driven by a ring-type velocity distribution and by interpenetrating ion beams in a time-variable magnetic field. Instability growth times are of the order of an ion gyroperiod in the case of the ring distribution and of the order of an ion plasma period in the case of the beam simulation. Maximum potential differences generated are of the order of the ion kinetic energies. These simulations demonstrate the cascade of wave energy to long wavelengths, thus showing the E x B turbulence can be generated from plasma microinstabilities. After the free energy feeding, the instabilities are exhausted, and wave energy at wavelengths less than an ion gyrodiameter decays quickly to equilibrium levels, while longer wavelength modes persist for much longer times. In one model with a time dependent, but spatially uniform, magnetic field the electric field energy at long wavelengths appeared to increase as a result of the increase of the magnetic field.

Swift, D. W.↗

Time evolution analysis of the electron distribution in Thomson/Compton back-scattering

We present the time evolution of the energy distribution of a relativistic electron beam after the Compton back-scattering with a counter-propagating laser field, performed in the framework of the Quantum Electrodynamics, by means of the code CAIN. As the correct angular distribution of the spontaneous emission is accounted, the main effect is the formation of few stripes, followed by the diffusion of the more energetic particles toward lower values in the longitudinal phase space. The Chapman-Kolmogorov master equation gives results in striking agreement with the numerical ones. An experiment on the Thomson source at SPARC-LAB is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

2.5-Dimensional numerical simulation of a high-current ion linear induction accelerator

Results are presented from numerical particle simulations of the transport and acceleration of a high-current tubular ion beam through one to five magnetically insulated accelerating gaps. The ion beam is neutralized by an accompanying electron beam. The possibility of transporting a high-current neutralized ion beam through five cusps is demonstrated. It is shown that the quality of the distribution function of a high-current ion beam at the exit from the accelerator can be substantially improved by optimizing the energy of the neutralizing electron beam. It is also shown that, by injecting additional high-current electron beams into the cusps, the accelerated ion beam can be made more monoenergetic and its divergence can be reduced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chemical and Structural Alterations in the Amorphous Structure of Obsidian due to Nanolites

Obsidian is volcanic glass that results from the rapid cooling of silica-rich melt. Nanoscale crystallites precipitate out of the melt prior to solidification and remain embedded in the amorphous matrix. These crystallites provide information on the flow kinetics and composition of the melt. Due to the sparsity and size of nanolites, studies often focus on supramicron crystallites. This research takes advantage of the conchoidal fracture of obsidian by knapping samples with nanometer-thin edges for transmission electron microscopy characterization. Nanolites in the amorphous matrix are studied using energy-dispersive spectroscopy (EDS) and electron diffraction. Certain alkali and alkaline-earth cations exhibit patterns of depletion near Fe-oxide nanolites. EDS is used to identify nanolites and variations in the composition of the matrix. Parallel beam diffraction and radial distribution function analysis of nearest-neighbor distances determine average bond lengths in the matrix near nanolites, showing that nanolites influence the nearby short-range ordering and atomic character of the matrix. Analysis reveals decreased mean nearest-neighbor distances in the matrix adjacent to nanolites compared to the bulk. Our methods exhibit the required sensitivity to detect variations in the composition and structure near nanolites, and our findings indicate that obsidian nanolites contribute to quantifiable localized changes in the amorphous structure.

36 MATERIALS SCIENCE↗

Atomic resolution mapping of interfacial intermixing and segregation in InAs/GaSb superlattices: A correlative study

We combine quantitative analyses of Z-contrast images with composition analyses employing atom probe tomography (APT) correlatively to provide a quantitative measurement of atomic scale interfacial intermixing in an InAs/GaSb superlattice (SL). Contributions from GaSb and InAs in the Z-contrast images are separated using an improved image processing technique. Correlation with high resolution APT composition analyses permits an examination of interfacial segregation of both cations and anions and their incorporation in the short period InAs/GaSb SL. Results revealed short, intermediate, and long-range intermixing of In, Ga, and Sb during molecular beam epitaxial growth and their distribution in the SL.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron cyclotron resonance ion source plasma characterization by X-ray spectroscopy and X-ray imaging

An experimental campaign aiming to investigate electron cyclotron resonance (ECR) plasma X-ray emission has been recently carried out at the ECRISs—Electron Cyclotron Resonance Ion Sources laboratory of Atomki based on a collaboration between the Debrecen and Catania ECR teams. In a first series, the X-ray spectroscopy was performed through silicon drift detectors and high purity germanium detectors, characterizing the volumetric plasma emission. The on-purpose developed collimation system was suitable for direct plasma density evaluation, performed “on-line” during beam extraction and charge state distribution characterization. A campaign for correlating the plasma density and temperature with the output charge states and the beam intensity for different pumping wave frequencies, different magnetic field profiles, and single-gas/gas-mixing configurations was carried out. The results reveal a surprisingly very good agreement between warm-electron density fluctuations, output beam currents, and the calculated electromagnetic modal density of the plasma chamber. A charge-coupled device camera coupled to a small pin-hole allowing X-ray imaging was installed and numerous X-ray photos were taken in order to study the peculiarities of the ECRIS plasma structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonant Slow Extraction Simulation using Bmad

Simulations of slow extraction and transport of charged particle beams from synchrotrons requires careful modeling and experimentation. In this paper, we outline how the Bmad modeling software was adapted and developed to run third-integer resonant extraction simulations of beams at Brookhaven National Laboratory’s Booster synchrotron. Further, we show experimental comparisons of the slowly extracted beams transferred to the NASA Space Radiation Laboratory (NSRL) transport line. In this process, beam passes through a stripping foil element at the extraction point, which, along with stripping remaining electrons from the beam ions, acts as a scatterer to modify the phase space, moving to a more Gaussian-like distribution. This modification to the beam helps generate a uniform beam at the beam line’s target location; which is necessary for the variety of experiments performed at the facility. During this work, beam energy loss and multiple scattering by foil routines were built in conjunction with the Bmad code developers and are now integrated into the software.

43 PARTICLE ACCELERATORS↗

Sub-shell closure and shape coexistence in the transitional nucleus Zr 98

In the rapid shape change from spherical to deformed nuclei in the Z=40 Zr isotopic chain, recent work has identified shape coexistence in 96 Zr. Between 96 Zr and the strongly deformed 100 Zr, 98 Zr is expected to also exhibit coexistence of nuclear shapes. The degree of mixing between different configurations is mainly determined by the nucleon-nucleon interactions. For nuclear model predictions, experimental constraints are needed, but they are barely available for 98 Zr. To study low-lying transitions in 98 Zr, a Coulomb excitation experiment was conducted at the Argonne Tandem-Linac Accelerator System (ATLAS) facility using a 98 Zr beam extracted from the Californium Rare Ion Breeder Upgrade (CARIBU) ion source and Gamma-Ray Energy Tracking In-beam Nuclear Array (GRETINA) for γ-ray spectroscopy coupled to the compact heavy ion counter (CHICO2) for ion detection. Furthermore, this paper reports on the first decisive deduction of the B(E2;2 + 1 →0 + 1 ) transition strength in 98 Zr and on its interpretation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Overall Traveling-Wave-Tube Efficiency Improved By Optimized Multistage Depressed Collector Design

Depressed Collector Design The microwave traveling wave tube (TWT) is used widely for space communications and high-power airborne transmitting sources. One of the most important features in designing a TWT is overall efficiency. Yet, overall TWT efficiency is strongly dependent on the efficiency of the electron beam collector, particularly for high values of collector efficiency. For these reasons, the NASA Glenn Research Center developed an optimization algorithm based on simulated annealing to quickly design highly efficient multistage depressed collectors (MDC's). Simulated annealing is a strategy for solving highly nonlinear combinatorial optimization problems. Its major advantage over other methods is its ability to avoid becoming trapped in local minima. Simulated annealing is based on an analogy to statistical thermodynamics, specifically the physical process of annealing: heating a material to a temperature that permits many atomic rearrangements and then cooling it carefully and slowly, until it freezes into a strong, minimum-energy crystalline structure. This minimum energy crystal corresponds to the optimal solution of a mathematical optimization problem. The TWT used as a baseline for optimization was the 32-GHz, 10-W, helical TWT developed for the Cassini mission to Saturn. The method of collector analysis and design used was a 2-1/2-dimensional computational procedure that employs two types of codes, a large signal analysis code and an electron trajectory code. The large signal analysis code produces the spatial, energetic, and temporal distributions of the spent beam entering the MDC. An electron trajectory code uses the resultant data to perform the actual collector analysis. The MDC was optimized for maximum MDC efficiency and minimum final kinetic energy of all collected electrons (to reduce heat transfer). The preceding figure shows the geometric and electrical configuration of an optimized collector with an efficiency of 93.8 percent. The results show the improvement in collector efficiency from 89.7 to 93.8 percent, resulting in an increase of three overall efficiency points. In addition, the time to design a highly efficient MDC was reduced from a month to a few days. All work was done in-house at Glenn for the High Rate Data Delivery Program. Future plans include optimizing the MDC and TWT interaction circuit in tandem to further improve overall TWT efficiency.

Vaden, Karl R.↗

Dust particle diffusion in ion beam transport region

Dust particles of μm size produced by a monoplasmatron ion source are observed by a laser light scattering. The scattered light signal from an incident laser at 532 nm wavelength indicates when and where a particle passes through the ion beam transport region. As the result, dusts with the size more than 10 μm are found to be distributed in the center of the ion beam, while dusts with the size less than 10 μm size are distributed along the edge of the ion beam. Floating potential and electron temperature at beam transport region are measured by an electrostatic probe. This observation can be explained by a charge up model of the dust in the plasma boundary region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Poster — Thur Eve — 46: Monte Carlo model of the Novalis Classic 6MV stereotactic linear accelerator using the GATE simulation platform

Monte Carlo (MC) simulation is accepted as the most accurate method to predict dose deposition when compared to other methods in radiation treatment planning. Current dose calculation algorithms used for treatment planning can become inaccurate when small radiation fields and tissue inhomogeneities are present. At our centre the Novalis Classic linear accelerator (linac) is used for Stereotactic Radiosurgery (SRS). The first MC model to date of the Novalis Classic linac was developed at our centre using the Geant4 Application for Tomographic Emission (GATE) simulation platform. GATE is relatively new, open source MC software built from CERN's Geometry and Tracking 4 (Geant4) toolkit. The linac geometry was modeled using manufacturer specifications, as well as in-house measurements of the micro MLC's. Among multiple model parameters, the initial electron beam was adjusted so that calculated depth dose curves agreed with measured values. Simulations were run on the European Grid Infrastructure through GateLab. Simulation time is approximately 8 hours on GateLab for a complete head model simulation to acquire a phase space file. Current results have a majority of points within 3% of the measured dose values for square field sizes ranging from 6×6 mm{sup 2} to 98×98 mm{sup 2} (maximum field size on the Novalis Classic linac) at 100 cm SSD. The x-ray spectrum was determined from the MC data as well. The model provides an investigation into GATE'S capabilities and has the potential to be used as a research tool and an independent dose calculation engine for clinical treatment plans.

60 APPLIED LIFE SCIENCES↗

Passive scheme with a photon-number-resolving detector for monitoring the untrusted source in a plug-and-play quantum-key-distribution system

A passive scheme with a beam splitter and a photon-number-resolving (PNR) detector is proposed to verify the photon statistics of an untrusted source in a plug-and-play quantum-key-distribution system by applying a three-intensity decoy-state protocol. The practical issues due to statistical fluctuation and detection noise are analyzed. The simulation results show that the scheme can work efficiently when the total number of optical pulses sent from Alice to Bob is above 10{sup 8}, and the dark count rate of the PNR detector is below 0.5 counts/pulse, which is realizable with current techniques. Furthermore, we propose a practical realization of the PNR detector with a variable optical attenuator combined with a threshold detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dosimetric verification of IMAT delivery with a conventional EPID system and a commercial portal dose image prediction tool

Purpose: The electronic portal imaging device (EPID) is a system for checking the patient setup; as a result of its integration with the linear accelerator and software customized for dosimetry, it is increasingly used for verification of the delivery of fixed-field intensity-modulated radiation therapy (IMRT). In order to extend such an approach to intensity-modulated arc therapy (IMAT), the combined use of an EPID system and a portal dose image prediction (PDIP) tool has been investigated. Methods: The dosimetric behavior of an EPID system, mechanically reinforced to maintain its positional stability during the accelerator gantry rotation, has been studied to assess its ability to measure portal dose distributions for IMAT treatment beams. In addition, the PDIP tool of a commercial treatment planning system, commonly used for static IMRT dosimetry, has been validated for simulating the PDIs of IMAT treatment fields. The method has been applied to the delivery verification of 23 treatment fields that were measured in their dual mode of IMRT and IMAT modalities. Results: The EPID system has proved to be appropriate for measuring the PDIs of IMAT fields; additionally the PDIP tool was able to simulate these accurately. The results are quite similar to those obtained for static IMRT treatment verification, although it was necessary to investigate the dependence of the EPID signal and of the accelerator monitor chamber response on variable dose rate. Conclusions: Our initial tests indicate that the EPID system, together with the PDIP tool, is a suitable device for the verification of IMAT plan delivery; however, additional tests are necessary to confirm these results.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Complete ALMA Map of the Fomalhaut Debris Disk

We present ALMA mosaic observations at 1.3 mm (223 GHz) of the Fomalhaut system with a sensitivity of 14 μ Jy/beam. These observations provide the first millimeter map of the continuum dust emission from the complete outer debris disk with uniform sensitivity, enabling the first conclusive detection of apocenter glow. We adopt an MCMC modeling approach that accounts for the eccentric orbital parameters of a collection of particles within the disk. The outer belt is radially confined with an inner edge of 136.3 ± 0.9 au and width of 13.5 ± 1.8 au. We determine a best-fit eccentricity of 0.12 ± 0.01. Assuming a size distribution power-law index of q = 3.46 ± 0.09, we constrain the dust absorptivity power-law index β to be 0.9 < β < 1.5. The geometry of the disk is robustly constrained with inclination 65.°6 ± 0.°3, position angle 337.°9 ± 0.°3, and argument of periastron 22.°5 ± 4.°3. Our observations do not confirm any of the azimuthal features found in previous imaging studies of the disk with Hubble Space Telescope , SCUBA, and ALMA. However, we cannot rule out structures ≤10 au in size or that only affect smaller grains. The central star is clearly detected with a flux density of 0.75 ± 0.02 mJy, significantly lower than predicted by current photospheric models. We discuss the implications of these observations for the directly imaged Fomalhaut b and the inner dust belt detected at infrared wavelengths.

79 ASTRONOMY AND ASTROPHYSICS↗

High Efficient THz Emission From Unbiased and Biased Semiconductor Nanowires Fabricated Using Electron Beam Lithography

Besides having perfect control on structural features, such as vertical alignment and uniform distribution by fabricating the wires via e-beam lithography and etching process, we also investigated the THz emission from these fabricated nanowires when they are applied DC bias voltage. To be able to apply a voltage bias, an interdigitated gold (Au) electrode was patterned on the high-quality InGaAs epilayer grown on InP substrate bymolecular beam epitaxy. Afterwards, perfect vertically aligned and uniformly distributed nanowires were fabricated in between the electrodes of this interdigitated pattern so that we could apply voltage bias to improve the THz emission. As a result, we achieved enhancement in the emitted THz radiation by ~four times, about 12 dB increase in power ratio at 0.25 THz with a DC biased electric field compared with unbiased NWs.

Biased emission↗