Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Signal detection in l/f noise of SQUID magnetometers

It is shown that the variance on the SQUID power spectrum in the l/f low frequency region is well behaved, i.e., any small frequency band may be treated as white noise in standard power spectrum estimation theory. Specifically a calibration signal is examined at 0.017 Hz with an equivalent energy referred to the SQUID input coil of 1 times 10 to the -30th J and a digitally recorded and analyzed record of 140 hr duration obtained an optimum S/N better than 400. The results are in good agreement with theory. In addition no deviation from the l/f dependence of the noise energy spectrum is seen down to frequencies below 10 to the -5th Hz. A commercially available SQUID and electronics system were used.

Cabrera, B.↗

Results of the 1980 NASA/JPL balloon flight solar cell calibration program

Thirty-eight modules were carried to an altitude of about 36 kilometers. In addition to the cell calibration program, an experiment to evaluate the calibration error versus altitude was performed. The calibrated cells can be used as reference standards in simulator testing of cells and arrays.

Seaman, C. H.↗

Measurement of very large flow angles with non-nulling seven-hole probes

This paper describes a method for measuring local direction and total and static pressures of a flow by means of a fixed probe, provided that the local air flow does not make an angle of more than 80 degrees with the axis of the probe. The probe is easily manufactured from standard-sized tubing materials. The power series calibration method used with the probe results in explicit polynomial expressions for the desired aerodynamic properties. The calibration method is easily programmed on a data acquisition system. This paper includes an example of a complete incompressible calibration.

Gallington, R. W.↗

Results of the 1987 NASA/JPL balloon flight solar cell calibration program

The 1987 solar cell calibration balloon flight was successfully completed on August 23, 1987, meeting all objectives of the program. Forty-eight modules were carried to an altitude of 120,000 ft (36.0 km). The cells calibrated can now be used as reference standards in simulator testing of cells and arrays.

Anspaugh, B. E.↗

XUV radiometric standards at NBS

The far-UV and XUV detector calibration services at NBS, the properties of the detectors, and the spectrometer calibration facilities at the Synchrotron Ultraviolet Radiation Facility (SURF II) at NBS are described. The method used to calibrate the quantum efficiency of windowless photodiode detectors in the ionization chamber, and the facilities for calibrating photodiodes at various wavelengths are discussed. The cathode and anode of the windowless photodiodes and their operation are examined. Consideration is given to the calculation of spectral irradiance from SURF II; the two stations of the spectrometer facility; the large spectrometer calibration chamber; and sources of error in flux determinations for SURF II.

Ott, W. R.↗

A one-equation turbulence transport model for high Reynolds number wall-bounded flows

A one-equation turbulence model that avoids the need for an algebraic length scale is derived from a simplified form of the standard k-epsilon model equations. After calibration based on well established properties of the flow over a flat plate, predictions of several other flows are compared with experiment. The preliminary results presented indicate that the model has predictive and numerical properties of sufficient interest to merit further investigation and refinement. The one-equation model is also analyzed numerically and robust solution methods are presented.

Baldwin, Barrett S.↗

Laer-induced Breakdown Spectroscopy Instrument for Element Analysis of Planetary Surfaces

One of the most fundamental pieces of information about any planetary body is the elemental and mineralogical composition of its surface materials. We are developing an instrument to obtain such data at ranges of up to several hundreds of meters using the technique of Laser-Induced Breakdown Spectroscopy (LIBS). We envision our instrument being used from a spacecraft in close rendezvous with small bodies such as comets and asteroids, or deployed on surface-rover vehicles on large bodies such as Mars and the Moon. The elemental analysis is based on atomic emission spectroscopy of a laser-induced plasma or spark. A pulsed, diode pumped Nd:YAG laser of several hundred millijoules optical energy is used to vaporize and electronically excite the constituent elements of a rock surface remotely located from the laser. Light emitted from the excited plasma is collected and introduced to the entrance slit of a small grating spectrometer. The spectrally dispersed spark light is detected with either a linear photo diode array or area CCD array. When the latter detector is used, the optical and spectrometer components of the LIBS instrument can also be used in a passive imaging mode to collect and integrate reflected sunlight from the same rock surface. Absorption spectral analysis of this reflected light gives mineralogical information that provides a remote geochemical characterization of the rock surface. We performed laboratory calibrations in air and in vacuum on standard rock powders to quantify the LIBS analysis. We performed preliminary field tests using commercially available components to demonstrate remote LIBS analysis of terrestrial rock surfaces at ranges of over 25 m, and we have demonstrated compatibility with a six-wheeled Russian robotic rover vehicle. Based on these results, we believe that all major and most minor elements expected on planetary surfaces can be measured with absolute accuracy of 10-15 percent and much higher relative accuracy. We have performed preliminary systems analysis of a LIBS instrument to evaluate probable mass and power requirements; results of this analysis are summarized.

Blacic, J.↗

PTTI applications at the limits of GPS

Canadian plans for precise time and time interval services are examined in the light of GPS capabilities developed for geodesy. We present our experience in establishing and operating a geodetic type GPS station in a time laboratory setting, and show sub-nanosecond residuals for time transfer between geodetic sites. We present our approach to establishing realistic standard uncertainties for short-term frequency calibration services over time intervals of hours, and for longer-term frequency dissemination at better than the 10(exp -15) level of accuracy.

Douglas, Rob J.↗

Volume 35, AMT-1 Cruise Report and Preliminary Results

This report documents the scientific activities on board the Royal Research Ship (RRS) 'James Clark Ross' during the irst Atlantic Meridional Transect (AMT-1), 21 September to 24 October 1995. The ship sailed from Grimsby (England) for Montevideo (Uruguay) and then continued on to Stanley (Falkland Islands). The primary objective of the AMT program is to investigate basic biological processes in the open Atlantic Ocean over very broad spatial scales. For AMT-1, the meridional range covered was approximately 50 deg N to 50 deg S or nearly 8,000 nmi. The measurements to be taken during the AMT cruises are fundamental for the calibration, validation, and continuing understanding of remotely sensed observations of biological oceanography. They are also important for understanding plankton community structure over latitudinal scales and the role of the world ocean in global carbon cycles. During AMT-1 a variety of instruments were used to map the physical, chemical, and biological structure of the upper 200 m of the water column. Ocean color measurements were made using state-of-the-art sensors, whose calibration was traceable to the highest international standards. New advances in fluorometry were used to measure photosynthetic activity, which was then used to further interpret primary productivity. A unique set of samples and data were collected for the planktonic assemblages that vary throughout the range of the transect. These data will yield new interpretations on community composition and their role in carbon cycling. While the various provinces of the Atlantic Ocean were being crossed, the partial pressure of CO2 was related to biological productivity. This comparison revealed the areas of drawdown of atmospheric CO2 and how these areas relate to the surrounding biological productivity. These data, plus the measurements of light attenuation and phytoplankton optical properties, will be used as a primary input for basin-scale biological productivity models to help develop ecosystem dynamics models which will be important for improving the forecasting abilities of modelers. The AMT program is also attempting to meet the needs of international agencies in their implementation of Sensor Intercomparison and Merger for Biological and Interdisciplinary Ocean Studies (SIMBIOS), a program to develop a methodology and operational capability to combine data products from the various ocean color satellite missions.

Hooker, Stanford B.↗

Heat Flux Sensor Testing

This viewgraph presentation provides information on the following objectives: Developing secondary calibration capabilities for MSFC's (Marshall Space Flight Center) Hot Gas Facility (HGF), a Mach 4 Aerothermal Wind Tunnel; Evaluating ASTM (American Society for Testing and Materials) slug/ thinskin calorimeters against current HGF heat flux sensors; Providing verification of baselined AEDC (Arnold Engineering Development Center) / Medtherm gage calibrations; Addressing future calibration issues involving NIST (National Institute of Standards and Technology) certified radiant gages.

Clark, D. W.↗

Comparison of Measurements: Cal/Val

Calibration and validation of satellite instruments is vital to long-term trend estimates of ozone and other trace species. A satellite instrument is calibrated by comparing it against a particular standard on the ground prior to launch or against know standards in flight. An instrument is validated by making a comparison of the same measurable or measurement. Validation is performed in a number of ways. In particular, measurements by ground, balloon, aircraft, and other satellite instruments are used to provide validation.

Newman, P.↗

How and Why to Do VLBI on GPS

In order to establish the position of the center of mass of the Earth in the International Celestial Reference Frame, observations of the Global Positioning Satellite (GPS) constellation using the IVS network are important. With a good frame-tie between the coordinates of the IVS telescopes and nearby GPS receivers, plus a common local oscillator reference signal, it should be possible to observe and record simultaneously signals from the astrometric calibration sources and the GPS satellites. The standard IVS solution would give the atmospheric delay and clock offsets to use in analysis of the GPS data. Correlation of the GPS signals would then give accurate orbital parameters of the satellites in the ICRF reference frame, i.e., relative to the positions of the astrometric sources. This is particularly needed to determine motion of the center of mass of the earth along the rotation axis.

Dickey, J. M.↗

Standard Practices for Usage of Inductive Magnetic Field Probes with Application to Electric Propulsion Testing

Inductive magnetic field probes (also known as B-dot probes and sometimes as B-probes or magnetic probes) are useful for performing measurements in electric space thrusters and various plasma accelerator applications where a time-varying magnetic field is present. Magnetic field probes have proven to be a mainstay in diagnosing plasma thrusters where changes occur rapidly with respect to time, providing the means to measure the magnetic fields produced by time-varying currents and even an indirect measure of the plasma current density through the application of Ampère's law. Examples of applications where this measurement technique has been employed include pulsed plasma thrusters and quasi-steady magnetoplasmadynamic thrusters. The Electric Propulsion Technical Committee (EPTC) of the American Institute of Aeronautics and Astronautics (AIAA) was asked to assemble a Committee on Standards (CoS) for Electric Propulsion Testing. The assembled CoS was tasked with developing Standards and Recommended Practices for various diagnostic techniques used in the evaluation of plasma thrusters. These include measurements that can yield either global information related to a thruster and its performance or detailed, local data related to the specific physical processes occurring in the plasma. This paper presents a summary of the standard, describing the preferred methods for fabrication, calibration, and usage of inductive magnetic field probes for use in diagnosing plasma thrusters. Inductive magnetic field probes (also called B-dot probes throughout this document) are commonly used in electric propulsion (EP) research and testing to measure unsteady magnetic fields produced by time-varying currents. The B-dot probe is relatively simple in construction, and requires minimal cost, making it a low-cost technique that is readily accessible to most researchers. While relatively simple, the design of a B-dot probe is not trivial and there are many opportunities for errors in probe construction, calibration, and usage, and in the post-processing of data that is produced by the probe. There are typically several ways in which each of these steps can be approached, and different applications may require more or less vigorous attention to various issues.

Polzin, Kurt A.↗

Radiation resistant hydrogen microsensors for fusion applications.

Quantifying the flux and energy of charge exchange neutrals to the walls of fusion experiments is important to understanding wall erosion and energy balance. Quantification of these fluxes is made much more difficult because they have very strong poloidal and toroidal variations. To facilitate such measurements, we have been developing compact, palladium metal oxide semiconductor (Pd-MOS) detectors. These devices are dosemetric detectors, which can evaluate differences between plasma discharges. To become widely used, however, such detectors must be made resistant to UV and x-ray induced damage, as well as high energy particle bombardment. We report here on the fabrication of Schottky diode Pd-MOS devices in which we have minimized the oxide thickness (to reduce the production of charges from UV and x-rays) and increased the Pd overlayer (to reduce charge production from high energy particles). The fabrication has been facilitated through use of an array of metallic posts to improve the Pd film adhesion. The efficacy of the film adhesion and comparison with standard detectors will be examined. Testing and calibration of the detectors is reported as a function of hydrogen flux and energy.

08 HYDROGEN↗

Establishing the World Reference for Measuring the Atmospheric Longwave Irradiance with Traceability to the International System of Units

Advancing climate change research requires accurate and traceable measurement of the atmospheric longwave irradiance. Current measurement capabilities are limited to an estimated uncertainty of larger than +/- 6 W/ m2 using the interim World Infrared Standard Group (WISG). Two independently designed and calibrated absolute radiometers measuring downwelling longwave irradiance were compared during five outdoor comparisons in 2013, 2015, and 2017 at the Physikalisch Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC) and the USA-DOE Atmospheric Radiation Measurement program (ARM) in the Southern Great Planes (SGP). Two Absolute Cavity Pyrgeometers (ACPs) developed by the National Renewable Energy Laboratory (NREL) and four Integrating Sphere Infrared Radiometers (IRISs) developed by PMOD/WRC took part in these intercomparisons. From five comparisons, the difference between the irradiance measured by the ACPs and IRISs varied from 0.2 W/ m2 to 2.5 W/ m2 based on the atmospheric conditions, which is within the combined stated uncertainties of +/-3 W/ m2. The irradiance measured by the WISG is lower than the average irradiance measured by ACPs and IRISs, magnitude of the difference varied from 0.2 W/m2 to 6.6 W/ m2 depending on the integrated water vapor. A concerted effort at the World Meteorological Organization (WMO) Commission for Instruments and Methods of Observation Commission (CIMO) Task Team on Radiation References (TT) started during a meeting from November 15 to 17, 2017 in the National Physical Laboratory (NPL), Teddington, United Kingdom to establish a world reference for measuring the atmospheric longwave irradiance with lower uncertainty and with traceability to SI units by using the ACPs and IRISs as the reference.

14 SOLAR ENERGY↗

Establishing the World Reference for Measuring the Atmospheric Longwave Irradiance with Traceability to the International System of Units

Advancing climate change research requires accurate and traceable measurement of atmospheric longwave irradiance. Measurement capabilities are limited to an estimated uncertainty of larger than +/- 6 W/m2 using the interim World Infrared Standard Group (WISG). Two independently designed and calibrated absolute radiometers measuring downwelling longwave irradiance were compared during five outdoor comparisons in 2013, 2015, and 2017 at the Physikalisch Meteorologisches Observatorium Davos World Radiation Center (PMOD/WRC) and the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement program (ARM) in the Southern Great Planes (SGP). Two Absolute Cavity Pyrgeometers (ACPs) developed by the National Renewable Energy Laboratory (NREL) and four Integrating Sphere Infrared Radiometers (IRISs) developed by PMOD/WRC took part in these intercomparisons.From the five comparisons, the difference between the irradiance measured by ACPs and IRISs varied from 0.2 W/m2 to 2.5 W/m2 based on atmospheric conditions, which is within the combined stated uncertainties of +/- 3 W/m2. The irradiance measured by the WISG is lower than the average irradiance measured by ACPs and IRISs. The magnitude of difference varied from 0.2 W/m2 to 6.6 W/m2 depending on the integrated water vapor. A concerted effort to establish a world reference for measuring the atmospheric longwave irradiance with lower uncertainty and with traceability to the International System of Units (SI) by using the ACPs and IRISs as the reference started at the World Meteorological Organization (WMO). The Commission for Instruments and Methods of Observation Commission (CIMO) Task Team on Radiation References (TT) meeting was held in 2017 at the National Physical Laboratory (NPL), in Teddington, United Kingdom to discuss specific recommendation on the traceability of the atmospheric longwave irradiance to the International System of units (SI).

14 SOLAR ENERGY↗

Novel Photonuclear Methods to Produce an Argon-37 Standard

The mission of this research is to explore novel photonuclear-based pathways into the production of 37Ar. Above-background detection levels of 37Ar uniquely indicates the occurrence of an underground nuclear explosion, produced from fission neutrons interacting in the surrounding environment through the 40Ca(n,a)37Ar reaction. The half-life of 35 days allows on-site inspectors (OSI) adequate time following the nuclear event to detect 37Ar and verify compliance or defiance of non-proliferation treaties such as the Comprehensive Nuclear-Test-Ban Treaty (CTBT). An 37Ar standard would give OSI the ability to calibrate their detectors and measure detector efficiency allowing for the quantification of detected activity, give OSI authentic samples to test detectors in field exercises, and improve models predicting diffusion pathways of 37Ar through the underground environment.

43 PARTICLE ACCELERATORS↗

Calibrating Historical IR Sensors Using GEO, and AVHRR Infrared Tropical Mean Calibration Models

Long-term, remote-sensing-based climate data records (CDRs) are highly dependent on having consistent, wellcalibrated satellite instrument measurements of the Earth's radiant energy. Therefore, by making historical satellite calibrations consistent with those of today's imagers, the Earth-observing community can benefit from a CDR that spans a minimum of 30 years. Most operational meteorological satellites rely on an onboard blackbody and space looks to provide on-orbit IR calibration, but neither target is traceable to absolute standards. The IR channels can also be affected by ice on the detector window, angle dependency of the scan mirror emissivity, stray-light, and detector-to-detector striping. Being able to quantify and correct such degradations would mean IR data from any satellite imager could contribute to a CDR. Recent efforts have focused on utilizing well-calibrated modern hyper-spectral sensors to intercalibrate concurrent operational IR imagers to a single reference. In order to consistently calibrate both historical and current IR imagers to the same reference, however, another strategy is needed. Large, well-characterized tropical-domain Earth targets have the potential of providing an Earth-view reference accuracy of within 0.5 K. To that effort, NASA Langley is developing an IR tropical mean calibration model in order to calibrate historical Advanced Very High Resolution Radiometer (AVHRR) instruments. Using Meteosat-9 (Met-9) as a reference, empirical models are built based on spatially/temporally binned Met-9 and AVHRR tropical IR brightness temperatures. By demonstrating the stability of the Met-9 tropical models, NOAA-18 AVHRR can be calibrated to Met-9 by matching the AVHRR monthly histogram averages with the Met-9 model. This method is validated with ray-matched AVHRR and Met-9 biasdifference time series. Establishing the validity of this empirical model will allow for the calibration of historical AVHRR sensors to within 0.5 K, and thereby establish a climate-quality IR data record.

Scarino, Benjamin↗