Uncertainty Budget for Detector-Based Absolute Radiometric Calibration With GLAMR

The accuracy of the absolute radiometric calibration (RadCal) for remote sensing instruments is essential to their wide range of applications. The uncertainty associated to the traditional source-based RadCal method is assessed at a 2% (k=1) or higher level for radiance measurement. To further improve the accuracy to meet the demands of climate studies, a detector-based approach using tunable lasers as a light source has been devised. The Goddard Laser for Absolute Measurement of Radiance, known as the GLAMR system, is a notable example of the incorporation of such technology. Using transfer radiometers calibrated at NIST as calibration standards, the absolute spectral response (ASR) function of a remote sensing instrument is measured with its uncertainty traceable to the International System of Units. This paper presents a comprehensive uncertainty analysis of the detector-based absolute RadCal using the GLAMR system. It identifies and examines uncertainty sources during the GLAMR RadCal test, including those from the GLAMR system, the testing configuration, and data processing methodologies. Analysis is carried out to quantify the contribution of each source and emphasize the most influential factors. It is shown that the calibration uncertainty of GLAMR RadCal can be better than 0.3% (k=1) in the wavelength range of 350-950 nm and 0.6% (k=1) between 950-2300 nm, with the exception of regions with strong water absorption. In addition, recommendations are made to refine the calibration process to further reduce the uncertainty.

Zhipeng Wang↗

Energy Performance Assessment of Radiant Cooling System through Modeling and Calibration at Component Level

The paper describes a case study of an information technology office building with a radiant cooling system and a conventional variable air volume (VAV) system installed side by side so that performancecan be compared. First, a 3D model of the building involving architecture, occupancy, and HVAC operation was developed in EnergyPlus, a simulation tool. Second, a different calibration methodology was applied to develop the base case for assessing the energy saving potential. This paper details the calibration of the whole building energy model to the component level, including lighting, equipment, and HVAC components such as chillers, pumps, cooling towers, fans, etc. Also a new methodology for the systematic selection of influence parameter has been developed for the calibration of a simulated model which requires large time for the execution. The error at the whole building level [measured in mean bias error (MBE)] is 0.2%, and the coefficient of variation of root mean square error (CvRMSE) is 3.2%. The total errors in HVAC at the hourly are MBE = 8.7% and CvRMSE = 23.9%, which meet the criteria of ASHRAE 14 (2002) for hourly calibration. Different suggestions have been pointed out to generalize the energy saving of radiant cooling system through the existing building system. So a base case model was developed by using the calibrated model for quantifying the energy saving potential of the radiant cooling system. It was found that a base case radiant cooling system integrated with DOAS can save 28% energy compared with the conventional VAV system.

Building Energy Simulation↗

Automated calibration of multistatic arrays

A method is disclosed for calibrating a multistatic array having a plurality of transmitter and receiver pairs spaced from one another along a predetermined path and relative to a plurality of bin locations, and further being spaced at a fixed distance from a stationary calibration implement. A clock reference pulse may be generated, and each of the transmitters and receivers of each said transmitter/receiver pair turned on at a monotonically increasing time delay interval relative to the clock reference pulse. Ones of the transmitters and receivers may be used such that a previously calibrated transmitter or receiver of a given one of the transmitter/receiver pairs is paired with a subsequently un-calibrated one of the transmitters or receivers of an immediately subsequently positioned transmitter/receiver pair, to calibrate the transmitter or receiver of the immediately subsequent transmitter/receiver pair.

42 ENGINEERING↗

First Four-Isotope Calibration of a Beta-Gamma Quad Detector

Beta-gamma coincidence detectors used for radioxenon detection are non-standard detector types, but still require energy and efficiency calibration. There are several methods that are commonly used to perform a detector calibration. ? NIST certified sealed source ? Relative measurement to compare to a calibrated detector ? Absolute efficiency calibration based on radioxenon gas samples. The method using actual radioxenon samples to make an absolute efficiency determination is the most desirable, but until recently it was not possible to produce all four isotopically pure radioxenon. The first four radioxenon isotope calibration is outlined here.

Cooper, Matthew W.↗

Experiments and numerical modeling of surrogate droplet combustion for a 93 octane gasoline calibration fuel

Gasoline is the world’s most prolific liquid transportation fuel for ground transportation vehicles. Yet, a fundamental understanding of its burning characteristics is still lacking. Complicating this matter is the highly multicomponent nature of gasoline (comprised of hundreds of chemical species) and the seasonable variability of its composition due to variations in the crude oil feedstocks used in refining. The need to bring order to this complex problem has led to development of calibration fuels (Tier II in presented study) which on average will provide repeatable metrics that replicate performance of refined gasoline for various engine designs. This study presents results of experiments using the configuration of an isolated droplet to study the combustion dynamics of calibration fuel and three different surrogates (S4, S5, S6) for the calibration fuel. Droplet burning is under microgravity conditions, where gas transport is determined entirely by fuel evaporation in order to promote spherical symmetry in the burning process. The initial droplet diameters ranged between 0.55 mm and 0.60 mm. The droplets were spark-ignited and their burning histories were recorded by digital video cameras to obtain quantitative data. For each fuel, the evolutions of droplet, flame, and soot-shell diameters were measured to calculate the burn rates, flame-droplet diameter ratios (FSR) and soot-droplet diameter ratios. Additionally, a detailed numerical modeling is presented. This simulation includes multicomponent phase equilibrium, unsteady gas and liquid transport, radiative heat transfer, internal liquid diffusion and detailed combustion chemistry of different fuels during their burning process. Experiment results show that the calibration fuel and surrogates have a close burn rates and FSR, and S5 presents a relatively similar results with calibration fuel. Predictions from the numerical simulation using the surrogate are compared with experiment measurements, which showed a good agreement with the experiment results, including the droplet burning rate and FSR.

Guo, Songtao↗

Trial-based calibration for audio-based identification, recognition, and detection system

The disclosed technologies include methods for generating a calibration model using data that is selected to match the conditions of a particular trial that involves an automated comparison of data samples, such as a comparison-based trial performed by an audio-based recognition, identification, or detection system. The disclosed technologies also include improved methods for selecting candidate data used to build the calibration model. The disclosed technologies further include methods for evaluating the performance of the calibration model and for rejecting a trial when not enough matched candidate data is available to build the calibration model. The disclosed technologies additionally include the use of regularization and automated data generation techniques to further improve the robustness of the calibration model.

McLaren, Mitchell Leigh↗

Bayesian optimization for inverse calibration of expensive computer models: A case study for Johnson-Cook model in machining

Inverse model calibration for identifying the constitutive model parameters can be computationally demanding for expensive-to-evaluate simulation models. Here, this paper presents a modified Bayesian optimization (BO) method, denoted as BO-bound, that incorporates theoretical bounds on the quantity of interest. A case study for the inverse calibration of the Johnson Cook (J-C) flow stress model parameters is presented using machining (cutting) force data. The results show fast calibration of the five J-C parameters within 25 simulations. In general, the BO-bound method is applicable for inverse calibration of any expensive simulation models as well as optimization problems with known bounds.

Bayesian optimization↗

Test-Based Calibration of Safety Factors for Capacity Models

In this paper, a simple procedure to calibrate the safety factor of capacity models is presented. The calibration can be carried out based on any available database of experimental tests, even of limited size. The procedure aims to assess the model capability of predicting the test results and to calibrate the safety factor so that the capacity equation meets the target reliability level required by the code or sought by the calibrator. After predicting each test of the database with the capacity equation under consideration, the test-prediction pairs are checked for the property of linearity, and the relative error for the properties of homoscedasticity and normality. Once these properties are fulfilled—which may require a nonlinear transformation of the test values and/or the predictions—the closed-form equation proposed in this paper is employed to compute a target design value. The model safety factor is finally obtained by comparing such target design value with the design value obtained from the code. The paper also proposes two approximate analytical equations to compute the tolerance factor, used to attain any given fractile, as a function of the (even small) number of tests, with any assigned confidence level. A fundamental outcome of the procedure is that it yields an objective indicator of the model accuracy, measured by the standard deviation of its error, which may be regarded as a parameter useful for selecting the most reliable model among different competing ones. In the long run, the application of the proposed procedure will allow achieving a uniform reliability level throughout all capacity models used in codes and guidelines. A further advantage is that the partial safety factors so derived can be straightforwardly updated when more experiments become available. Finally, as an example, the proposed procedure is herein applied to the ACI 318 shear design capacity equation for concrete members unreinforced in shear.

42 ENGINEERING↗

Implementation of an in-vessel calibration light source for JET

An in-vessel calibration light source (ICLS) has been implemented for remote use during extended shutdown periods of the Joint European Torus (JET). The ICLS facilitated the in situ calibration of optical diagnostics, which previously were performed when the diagnostics were removed from JET. Since the ICLS is used to calibrate diagnostics over the entire, exact optical path as used when plasma discharge data are measured, the ICLS calibration implicitly accounts for any vignetting losses in the JET vessel viewports in addition to the vacuum window transmission. At least ten diagnostic systems have benefited from the ICLS during the extended ITER-like wall shutdown of 2009-2011. Examples of the use of the ICLS in JET are given.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Model Reduction, Validation, and Calibration of Wind Power Plants for Dynamic Studies

Accurate representation of wind power plants (WPP) in both offline and online power system stability studies has gained importance because of the rapid increase in installation of wind generation around the world. On the other hand, reduced WPP representation is preferred due to computational efficiency. To improve the accuracy, other authors have proposed changes in structure of the reduced model for large WPPs. The use of model validation and calibration is an alternative to improve the accuracy of the reduced WPP model. In this paper, we compare accuracy improvements brought by changes in model structure with accuracy improvements brought by validation and calibration of the reduced WPP model with minimal changes in structure. We illustrate our findings using a 168-machine WPP connected to the IEEE-39-bus test system. The parameters of the reduced WPP model are either calculated with current equivalencing techniques or validated and calibrated against a more accurate model. The changes in structure of the reduced model are 1-machine or 2-machine reduced models connected with a 1-line or 2-line collector equivalents. We show that the most accurate response is obtained by calibrating the parameters of the reduced model with minimum changes in structure.

17 WIND ENERGY↗

FY2008 Calibration Systems Final Report

The Calibrations project has been exploring alternative technologies for calibration of passive sensors in the infrared (IR) spectral region. In particular, we have investigated using quantum cascade lasers (QCLs) because these devices offer several advantages over conventional blackbodies such as reductions in size and weight while providing a spectral source in the IR with high output power. These devices can provide a rapid, multi-level radiance scheme to fit any nonlinear behavior as well as a spectral calibration that includes the fore-optics, which is currently not available for on-board calibration systems.

47 OTHER INSTRUMENTATION↗

On-Orbit Calibration of a Multi-Spectral Satellite Satellite Sensor Using a High Altitude Airborne Imaging Spectrometer

Earth-looking satellites must be calibrated in order to quantitatively measure and monitor components of land, water and atmosphere of the Earth system. The inevitable change in performance due to the stress of satellite launch requires that the calibration of a satellite sensor be established and validated on-orbit. A new approach to on-orbit satellite sensor calibration has been developed using the flight of a high altitude calibrated airborne imaging spectrometer below a multi-spectral satellite sensor.

sensor calibration calibration Earth-looking satel↗

MODIS and VIIRS Calibration and Characterization in Support of Producing Long-Term High-Quality Data Products

Terra and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) have successfully operated since their launches in 1999 and 2002, respectively, and generated various data products to support the Earth remote sensing disciplines and users worldwide for their research activities and applications, including studies of the Earth system, and its changes over time and geographic regions. The MODIS data have also significantly contributed to the continuity of multi-decadal satellite data records and led to major advances in the Earth remote sensing field. The long-term data records from MODIS observations have been and will continue to be extended by the Visible Infrared Imaging Radiometer Suite (VIIRS) instruments, currently operated aboard the Suomi-National Polar-Orbiting Partnership (NPP) and NOAA-20 satellites. The data quality of satellite instruments strongly depends on their calibration accuracy and stability. In order to help scientists and users gain a better understanding of MODIS and VIIRS data quality, this paper provides an overview of their on-orbit calibration methodologies, approaches, and results derived from instrument on-board calibrators and lunar observations, as well as select Earth view targets. What is also discussed is the calibration consistency between MODIS and VIIRS and its potential impact on producing multi-sensor long-term data records. As illustrated, the overall performance of both MODIS and VIIRS continues to meet their design requirements.

MODIS↗

Quantifying model structural error: Efficient Bayesian calibration of a regional groundwater flow model using surrogates and a data-driven error model

Groundwater model structural error is ubiquitous, due to simplification and/or misrepresentation of real aquifer systems. During model calibration, the basic hydrogeological parameters may be adjusted to compensate for structural error. This may result in biased predictions when such calibrated models are used to forecast aquifer responses to new forcing. Here, we investigate the impact of model structural error on calibration and prediction of a real-world groundwater flow model, using a Bayesian method with a data-driven error model to explicitly account for model structural error. The error-explicit Bayesian method jointly infers model parameters and structural error and thereby reduces parameter compensation. In this study, Bayesian inference is facilitated using high performance computing and fast surrogate models (based on machine learning techniques) as a substitute for the computationally expensive groundwater model. We demonstrate that with explicit treatment of model structural error, the Bayesian method yields parameter posterior distributions that are substantially different from those derived using classical Bayesian calibration that does not account for model structural error. We also found that the error-explicit Bayesian method gives signficantly more accurate prediction along with reasonable credible intervals. Finally, through variance decomposition, we provide a comprehensive assessment of prediction uncertainty contributed from parameter, model structure, and measurement uncertainty. The results suggest that the error-explicit Bayesian approach provides a solution to real-world modeling applications for which data support the presence of model structural error, yet model deficiency cannot be specifically identified or corrected.

54 ENVIRONMENTAL SCIENCES↗

Flood hazard model calibration using multiresolution model output

Riverine floods pose a considerable risk to many communities. Improving flood hazard projections has the potential to inform the design and implementation of flood risk management strategies. Current flood hazard projections are uncertain, especially due to uncertain model parameters. Calibration methods use observations to quantify model parameter uncertainty. With limited computational resources, researchers typically calibrate models using either relatively few expensive model runs at high spatial resolutions or many cheaper runs at lower spatial resolutions. This leads to an open question: is it possible to effectively combine information from the high and low resolution model runs? We propose a Bayesian emulation–calibration approach that assimilates model outputs and observations at multiple resolutions. As a case study for a riverine community in Pennsylvania, we demonstrate our approach using the LISFLOOD-FP flood hazard model. Here, the multiresolution approach results in improved parameter inference over the single resolution approach in multiple scenarios. Results vary based on the parameter values and the number of available models runs. Our method is general and can be used to calibrate other high dimensional computer models to improve projections.

multiresolution↗

Calibration and uncertainty quantification for Davis Equation of State models for the High Explosive PBX 9501 products

Abstract This paper investigates the uncertainty in the parameters used in the calibration of an Davis Equation Of State (EOS) for the detonation products of the High Explosive PBX 9501. The procedure sought to make use of all available information about this HE to inform the best set of calibration parameters as well as the uncertainty in these parameters. The procedure made use of historical experimental data, the results from thermo‐chemical modeling as well as data on the best isentrope function fit to cylinder test experimental data. Combining all these heterogeneous data sources together in a Bayesian calibration, yielded a posterior mean and covariance. Sampling from the posterior distribution and evaluating an important Quantity Of Interest (QOI) in the EOS model, the detonation speed of a one‐inch rate stick, produced a distribution which showed variations which were in agreement with experiments. The uncertainty in the EOS was reported as eleven sets of model calibrations which spanned the range of this QOI.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A comparison of Gaussian processes and neural networks for computer model emulation and calibration

The Department of Energy relies on complex physics simulations for prediction in domains like cosmology, nuclear theory, and materials science. These simulations are often extremely computationally intensive, with some requiring days or weeks for a single simulation. In order to assure their accuracy, these models are calibrated against observational data in order to estimate inputs and systematic biases. Because of their great computational complexity, this process typically requires the construction of an emulator, a fast approximation to the simulation. In this paper, two emulator approaches are compared: Gaussian process regression and neural networks. Their emulation accuracy and calibration performance on three real problems of Department of Energy interest is considered. On these problems, the Gaussian process emulator tends to be more accurate with narrower, but still well-calibrated uncertainty estimates. The neural network emulator is accurate, but tends to have large uncertainty on its predictions. Finally, as a result, calibration with the Gaussian process emulator produces more constrained posteriors that still perform well in prediction.

97 MATHEMATICS AND COMPUTING↗

Broadband Calibration of Acoustic Emission and Ultrasonic Sensors from Generalized Ray Theory and Finite Element Models

This paper describes a calibration method for acoustic emission and ultrasonic sensors that is effective from 1 kHz to 1 MHz. The method combines generalized ray theory and finite element analysis to model wave propagation at higher and lower frequencies, respectively. A ball impact is used as a calibration source, a thick aluminum plate is used as the test block, and hot glue is used as the couplant. We demonstrate this method on five commercial piezoelectric sensors: Physical Acoustics (PAC) R15a, PAC WSa, Panametrics V101, Panametrics V103, and Valpey-Fisher Pinducer. Our calibration results show that reflections and other wave phases can be more clearly identified with the less-resonant Panametrics sensors. The PAC sensors have the greatest sensitivity and are able to detect surface normal displacements at least down to 1 pm amplitude in the 100s of kHz frequency band. Aperture effect is minimized by the small size of the Pinducer. Our method focuses on the amplitude response of the sensors (phase is ignored) and extends the calibration to a frequency band that is lower than typical analyses. Low frequency information is useful for determining the seismic moment of a seismic source (analogous to the magnitude of an earthquake) and can increase the amount of information acquired in a single recording.

42 ENGINEERING↗