Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparative visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

In‐operando crystallization study of zinc nitrate hexahydrate using zinc oxide nucleators

Abstract Supercooling (∆T Sup ) is one of the crucial problems in utilizing a phase change material (PCM), which has been attempted to overcome using nucleators possessing small lattice disregistry without comprehensive understanding of the nucleation phenomenon. Here, this work studies the interactions between nucleators and PCM via in‐operando direct visualization for the first time, to the best of our knowledge, to better understand the crystallization process during freezing of a PCM using zinc nitrate hexahydrate (ZNH) and a zinc oxide (ZnO) nucleator. According to our in‐operando study, freezing was randomly initiated by only a fraction of the nucleator particles during each thermal cycling. However, previously unresponsive nucleators also suddenly crystalized PCM when the propagating crystal encountered them, improving the crystal initiation and thereby ∆T Sup . Consequently, for equal wt% of ZnO, better nucleation behavior was obtained using uniformly distributed small nucleator particles throughout the PCM, as compared to either large or poorly distributed aggregated nucleators. DSC results using ZnO‐needle as nucleator confirmed a 38% and 33.3% lower ∆T Sup upon employing 5 wt% small (individual) particles (~4 μm on average), as compared to using equal wt% of small (aggregated) particle clusters (~200 μm) and large particles (~46 μm), respectively. Crystallization of ZNH caused additional hair‐like ZnO growth preferentially decorated along lateral faces of the original nucleator particles. The in‐operando studies are valuable tools to correlate inherent crystallization phenomena to the practical thermal energy storage properties of the system.

Chakraborty, Anirban↗

Water and chloride ions migration in porous cementitious materials: An experimental and molecular dynamics investigation

The interactions of water and chloride ions penetration into porous mortar have been investigated experimentally and modelled by molecular dynamics. The water distribution visualized by neutron radiography and chloride penetration by Electron Probe Micro-Analysis indicate that separation of chloride ions from water during the penetration process took place and water ran much deeper into the material than chloride ions. The relationship between the penetration depth of water and chloride ions can be described by a linear function despite different water-cement ratio. Furthermore, molecular dynamics attributes the different transport mechanisms of water and ions in porous cementitious materials to three reasons: the nanostructure of hydration product play filtering role to screen chloride ions with larger hydration shell; as compared with water, ions reside in the calcium silicate surface for longer time due to the strong interfacial bonding; chloride ions accumulate and form CaCl ionic cluster, slowing down the migrating rate.

36 MATERIALS SCIENCE↗

Dimensionality effects on multicomponent ionic transport and surface complexation in porous media

Coulombic interactions between charged species in pore water and at surface/solution interfaces are of pivotal importance for multicomponent reactive transport in porous media. In this study, we investigate the impact of domain dimensionality on electrostatically coupled dispersion and surface-solution reactions during transport of acidic plumes and major ions in porous media. Column and quasi two-dimensional flow-through experiments were performed, with identical silica porous media and under the same advection-dominated conditions. Equal mass fluxes of different electrolyte solutions (i.e., HCl - pH ~ 2.8, NaBr - 100 mM, HCl - pH ~ 2.8 plus NaBr - 100 mM) were continuously injected in the 1-D and 2-D experiments and breakthrough curves of pH and major ions were measured at the outlet of the domains. The presence of pronounced ionic strength gradients in the transverse direction in the 2-D setup caused distinct retardation and transport behaviors of protons and major ions which were not observed in the one-dimensional column experiments. Furthermore, in the cases of salt electrolytes injection, considerably enhanced release of H + (>61%) from the quartz surface was observed in the multidimensional system compared to the one-dimensional setup. Reactive transport modeling was performed to reproduce the experimental outcomes and to analyse the coupling between transport processes, based on the Nernst-Planck formulation of diffusive/dispersive fluxes and on surface complexation reactions at the solid-solution interface. Electrostatic interactions between Na + , B – , and H + , and deprotonation of the quartz surface upon the formation of sodium outer-sphere complexes, are the primary controllers of the spatial and temporal features displayed by the pH and major ions measurements. The reactive transport simulations allowed us to interpret the experimental observations, to visualize the distribution and spatio-temporal evolution of dissolved and solid species, to identify a spatially heterogeneous zonation of Coulombic interactions with distinct behavior at the fringe and core of the injected plumes in the multidimensional setup, and to quantify the different components of the Nerst-Planck fluxes of the charged solutes. This study demonstrates that the domain dimensionality directly affects electrostatic interactions between charged aqueous species in the pore water and surface complexation reactions at the solid-solution interface. The non-trivial effects of dimensionality on multicomponent ionic transport result in a significantly different behavior in 1-D and 2-D systems.

58 GEOSCIENCES↗

Magnetic Resonance Imaging-Based Radiation-Absorbed Dose Estimation of {sup 166}Ho Microspheres in Liver Radioembolization

Purpose: To investigate the potential of magnetic resonance imaging (MRI) for accurate assessment of the three-dimensional {sup 166}Ho activity distribution to estimate radiation-absorbed dose distributions in {sup 166}Ho-loaded poly (L-lactic acid) microsphere ({sup 166}Ho-PLLA-MS) liver radioembolization. Methods and Materials: MRI, computed tomography (CT), and single photon emission CT (SPECT) experiments were conducted on an anthropomorphic gel phantom with tumor-simulating gel samples and on an excised human tumor-bearing liver, both containing known amounts of {sup 166}Ho-PLLA-MS. Three-dimensional radiation-absorbed dose distributions were estimated at the voxel level by convolving the {sup 166}Ho activity distribution, derived from quantitative MRI data, with a {sup 166}Ho dose point-kernel generated by MCNP (Monte Carlo N-Particle transport code) and from Medical Internal Radiation Dose Pamphlet 17. MRI-based radiation-absorbed dose distributions were qualitatively compared with CT and autoradiography images and quantitatively compared with SPECT-based dose distributions. Both MRI- and SPECT-based activity estimations were validated against dose calibrator measurements. Results: Evaluation on an anthropomorphic phantom showed that MRI enables accurate assessment of local {sup 166}Ho-PLLA-MS mass and activity distributions, as supported by a regression coefficient of 1.05 and a correlation coefficient of 0.99, relating local MRI-based mass and activity calculations to reference values obtained with a dose calibrator. Estimated MRI-based radiation-absorbed dose distributions of {sup 166}Ho-PLLA-MS in an ex vivo human liver visually showed high correspondence to SPECT-based radiation-absorbed dose distributions. Quantitative analysis revealed that the differences in local and total amounts of {sup 166}Ho-PLLA-MS estimated by MRI, SPECT, and the dose calibrator were within 10%. Excellent agreement was observed between MRI- and SPECT-based dose-volume histograms. Conclusions: Quantitative MRI was demonstrated to provide accurate three-dimensional {sup 166}Ho-PLLA-MS activity distributions, enabling localized intrahepatic radiation-absorbed dose estimation by convolution with a {sup 166}Ho dose point-kernel for liver radioembolization treatment optimization and evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Non-linear enhancement of ultrafast X-ray diffraction through transient resonances

Diffraction-before-destruction imaging with ultrashort X-ray pulses can visualize non-equilibrium processes, such as chemical reactions, with sub-femtosecond precision in the native environment. Here, a nanospecimen diffracts a single X-ray flash before it disintegrates. The sample structure can be reconstructed from the coherent diffraction image (CDI). State-of-the-art X-ray snapshots lack high spatial resolution because of weak diffraction signal. Bleaching effects from photo-ionization significantly restrain image brightness scaling. We find that non-linear transient ion resonances can overcome this barrier if X-ray laser pulses are shorter than in most experiments. We compared snapshots from individual ≈ 100 nm Xe nanoparticles as a function of pulse duration and incoming X-ray fluence. Our experimental results and Monte Carlo simulations suggest that transient resonances can increase ionic scattering cross sections significantly beyond literature values. This provides a novel avenue towards substantial improvement of the spatial resolution in CDI in combination with sub-femtosecond temporal precision at the nanoscale.

47 OTHER INSTRUMENTATION↗

A new method for analyzing and visualizing plasma simulations using a phase-space tessellation

We apply a novel phase-space interpolation technique referred to as the simplex-in-cell (SIC) method to analyze two- and three-dimensional particle-in-cell (PIC) simulations of electromagnetic plasmas. SIC relies on a discretization of the initial phase-space distribution function into simplices, which allows an approximation to the full, continuously defined distribution function to be constructed at any later time in the simulation. This allows densities, currents, and even full momentum distribution functions to be measured at any point in the simulation domain without averaging over control volumes. The SIC approach applies to any PIC simulation for which a tessellation of the initial particle distribution can be constructed. In this study, we use outputs from standard PIC simulations of the Weibel instability and compare physical quantities such as charge and current densities calculated in postprocessing using SIC and standard particle deposits. Using 2D simulations with 1–65 536 particles-per-cell, we find that SIC eliminates discrete particle noise and in some cases can reach a given noise level using ~1000 times fewer simulation particles than with standard particle deposition schemes. In regions of low density, such as between current filaments, SIC is able to capture small amplitude features even with fewer particles than gridpoints due to the deformable nature of the SIC volume elements. Here, by calculating momentum distributions, we show how SIC can capture low density tails in the spectrum using far fewer particles than are necessary for standard particle deposits. We calculate the charge density on spatial grids of increasing resolution to demonstrate the ability of SIC to reveal fine-scale details that are not accessible with standard particle deposits. Finally, we show how SIC can be extended to 3D and give an example of its use to calculate the charge density from 3D PIC simulations of the Weibel instability. These results motivate the future implementation of SIC directly in the simulation force calculation for a novel low-noise electromagnetic plasma simulation method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling and experimental validation of dynamical effects in Bragg coherent x-ray diffractive imaging of finite crystals

Bragg coherent diffractive imaging (BCDI) is a noninvasive microscopy technique that can visualize the shape and internal lattice deviations of crystals with nanoscale spatial resolution and picometer deformation sensitivity. Its strain imaging capability relies on Fourier transform–based iterative phase retrieval algorithms, which are mostly developed under the kinematical approximation. Such approximation prohibits the application of BCDI on larger crystals, which are commonly seen in most emerging functional materials. Understanding the dynamical effect in BCDI, as well as developing a validated method for modeling BCDI at the dynamical diffraction limit, is crucial for applying BCDI to hierarchical systems that contain micron-sized crystals and grains. Thus we report a comparative study on the impact of dynamical diffraction effects by comparing the reconstruction results from two measurements of the same crystal. Forward simulation is implemented to show subtle changes of interference fringes in the diffraction pattern due to the dynamical diffraction, and is compared directly with the experimental data.

36 MATERIALS SCIENCE↗

Molecular radiotherapy: The NUKFIT software for calculating the time-integrated activity coefficient

Purpose: Calculation of the time-integrated activity coefficient (residence time) is a crucial step in dosimetry for molecular radiotherapy. However, available software is deficient in that it is either not tailored for the use in molecular radiotherapy and/or does not include all required estimation methods. The aim of this work was therefore the development and programming of an algorithm which allows for an objective and reproducible determination of the time-integrated activity coefficient and its standard error.Methods: The algorithm includes the selection of a set of fitting functions from predefined sums of exponentials and the choice of an error model for the used data. To estimate the values of the adjustable parameters an objective function, depending on the data, the parameters of the error model, the fitting function and (if required and available) Bayesian information, is minimized. To increase reproducibility and user-friendliness the starting values are automatically determined using a combination of curve stripping and random search. Visual inspection, the coefficient of determination, the standard error of the fitted parameters, and the correlation matrix are provided to evaluate the quality of the fit. The functions which are most supported by the data are determined using the corrected Akaike information criterion. The time-integrated activity coefficient is estimated by analytically integrating the fitted functions. Its standard error is determined assuming Gaussian error propagation. The software was implemented using MATLAB.Results: To validate the proper implementation of the objective function and the fit functions, the results of NUKFIT and SAAM numerical, a commercially available software tool, were compared. The automatic search for starting values was successfully tested for reproducibility. The quality criteria applied in conjunction with the Akaike information criterion allowed the selection of suitable functions. Function fit parameters and their standard error estimated by using SAAM numerical and NUKFIT showed differences of <1%. The differences for the time-integrated activity coefficients were also <1% (standard error between 0.4% and 3%). In general, the application of the software is user-friendly and the results are mathematically correct and reproducible. An application of NUKFIT is presented for three different clinical examples.Conclusions: The software tool with its underlying methodology can be employed to objectively and reproducibly estimate the time integrated activity coefficient and its standard error for most time activity data in molecular radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-595: Design of a Graphical User Interface for An In-House Monte Carlo Based Treatment Planning System: Planning and Contouring Tools

Purpose: An in-house Monte Carlo based treatment planning system (MC TPS) has been developed for modulated electron radiation therapy (MERT). Our preliminary MERT planning experience called for a more user friendly graphical user interface. The current work aimed to design graphical windows and tools to facilitate the contouring and planning process. Methods: Our In-house GUI MC TPS is built on a set of EGS4 user codes namely MCPLAN and MCBEAM in addition to an in-house optimization code, which was named as MCOPTIM. Patient virtual phantom is constructed using the tomographic images in DICOM format exported from clinical treatment planning systems (TPS). Treatment target volumes and critical structures were usually contoured on clinical TPS and then sent as a structure set file. In our GUI program we developed a visualization tool to allow the planner to visualize the DICOM images and delineate the various structures. We implemented an option in our code for automatic contouring of the patient body and lungs. We also created an interface window displaying a three dimensional representation of the target and also showing a graphical representation of the treatment beams. Results: The new GUI features helped streamline the planning process. The implemented contouring option eliminated the need for performing this step on clinical TPS. The auto detection option for contouring the outer patient body and lungs was tested on patient CTs and it was shown to be accurate as compared to that of clinical TPS. The three dimensional representation of the target and the beams allows better selection of the gantry, collimator and couch angles. Conclusion: An in-house GUI program has been developed for more efficient MERT planning. The application of aiding tools implemented in the program is time saving and gives better control of the planning process.

60 APPLIED LIFE SCIENCES↗

Quality assurance for online adapted treatment plans: Benchmarking and delivery monitoring simulation

Purpose: An important challenge facing online adaptive radiation therapy is the development of feasible and efficient quality assurance (QA). This project aimed to validate the deliverability of online adapted plans and develop a proof-of-concept online delivery monitoring system for online adaptive radiation therapy QA. Methods: The first part of this project benchmarked automatically online adapted prostate treatment plans using traditional portal dosimetry IMRT QA. The portal dosimetry QA results of online adapted plans were compared to original (unadapted) plans as well as randomly selected prostate IMRT plans from our clinic. In the second part, an online delivery monitoring system was designed and validated via a simulated treatment with intentional multileaf collimator (MLC) errors. This system was based on inputs from the dynamic machine information (DMI), which continuously reports actual MLC positions and machine monitor units (MUs) at intervals of 50 ms or less during delivery. Based on the DMI, the system performed two levels of monitoring/verification during the delivery: (1) dynamic monitoring of cumulative fluence errors resulting from leaf position deviations and visualization using fluence error maps (FEMs); and (2) verification of MLC positions against the treatment plan for potential errors in MLC motion and data transfer at each control point. Validation of the online delivery monitoring system was performed by introducing intentional systematic MLC errors (ranging from 0.5 to 2 mm) to the DMI files for both leaf banks. These DMI files were analyzed by the proposed system to evaluate the system’s performance in quantifying errors and revealing the source of errors, as well as to understand patterns in the FEMs. In addition, FEMs from 210 actual prostate IMRT beams were analyzed using the proposed system to further validate its ability to catch and identify errors, as well as establish error magnitude baselines for prostate IMRT delivery. Results: Online adapted plans were found to have similar delivery accuracy in comparison to clinical IMRT plans when validated with portal dosimetry IMRT QA. FEMs for the simulated deliveries with intentional MLC errors exhibited distinct patterns for different MLC error magnitudes and directions, indicating that the proposed delivery monitoring system is highly specific in detecting the source of errors. Implementing the proposed QA system for online adapted plans revealed excellent delivery accuracy: over 99% of leaf position differences were within 0.5 mm, and >99% of pixels in the FEMs had fluence errors within 0.5 MU. Patterns present in the FEMs and MLC control point analysis for actual patient cases agreed with the error pattern analysis results, further validating the system’s ability to reveal and differentiate MLC deviations. Calculation of the fluence map based on the DMI was performed within 2 ms after receiving each DMI input. Conclusions: The proposed online delivery monitoring system requires minimal additional resources and time commitment to the current clinical workflow while still maintaining high sensitivity to leaf position errors and specificity to error types. The presented online delivery monitoring system therefore represents a promising QA system candidate for online adaptive radiation therapy.

07 ISOTOPE AND RADIATION SOURCES↗

Spatiotemporal characterization of the field-induced insulator-to-metal transition

Watching a metal filament grow Resistive switching is a process in which the electrical resistance of a sample changes abruptly in response to a voltage pulse, often by orders of magnitude. This process is at the heart of many neuromorphic computing approaches but visualizing it in both space and time is tricky. del Valle et al . monitored the resistive switching in three different vanadium oxide compounds by measuring time- and space-resolved optical reflectivity (see the Perspective by Hilgenkamp and Gao). A characteristic conducting filament was quickly nucleated on the inhomogeneities in the sample and then propagated due to Joule heating. —JS

Science & Technology - Other Topics↗

Assessment of Mechanical Draft Cooling Tower Thermal Emissions from Visual Images of Plumes

Using a one-dimensional code, we computed the power (enthalpy discharge rate) of a twelve-cell mechanical draft cooling tower (MDCT) using over two hundred visible condensed water vapor plume volume measurements derived from images, weather data, and tower operating conditions. The plume images were simultaneously captured by multiple stationary digital cameras surrounding the cooling tower. An analysis technique combining structure from motion (SfM), a neural-network-based image segmentation algorithm, and space carving was used to quantify the volumes. Afterwards, the power output was computed using novel techniques in the one-dimensional code that included cooling tower exhaust plume adjacency effects implemented with a modified version of the entrainment function, weather data averaged from eleven stations, and fan operations at the times when plume volumes were measured. The model was then compared with the averaged observed power output, and it validated well with an average error ranging from 6 to 12%, depending on the meteorological data used in the simulations. This methodology can possibly determine power plant fuel consumption rates by applying visible imagery.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tanana River Test Site Model Verification Using the Marine and Hydrokinetic Toolkit (MHKiT)

The marine energy (ME) industry historically lacked a standardized data processing toolkit for common tasks such as data ingestion, quality control, and visualization. The marine and hydrokinetic toolkit (MHKiT) solved this issue by providing a public software deployment (open-source and free) toolkit for the ME industry to store and maintain commonly used functionality for wave, tidal, and river energy. This paper demonstrates an initial model verification study in MHKiT. Using Delft3D, a numerical model of the Tanana River Test Site (TRTS) at Nenana, Alaska was created. Field data from the site was collected using an Acoustic Doppler Current Profiler (ADCP) at the proposed Current Energy Converter (CEC) locations. MHKiT is used to process model simulations from Delft3D and compare them to the transect data from the ADCP measurements at TRTS. The ability to use a single tool to process simulation and field data demonstrates the ease at which the ME industry can obtain results and collaborate across specialties, reducing errors and increasing efficiency.

13 HYDRO ENERGY↗

Origin of relaxor behavior in 0.78(Na0.5Bi0.5)TiO3-0.2SrTiO3-0.02BaTiO3 ceramic: An electrical modulus study

Highlights: • Implementation of IS technique to study thermal evolution of polar nano regions. • Indirect evidence of the existence of polar nano regions well above T{sub B} and below T{sub f}. • Visualization of relaxation dynamics of PNRs on cooling by a schematic diagram. - Abstract: The relaxation dynamics of the polar nano-regions (PNRs) in the 0.78Na{sub 0.5}Bi{sub 0.5}TiO{sub 3}-0.2SrTiO{sub 3}-0.02BaTiO{sub 3} lead free ternary system over a wide temperature range (50–650 °C) is investigated using complex electric modulus formalism. The modulus spectra are analyzed across three characteristic temperatures T{sub B}, T{sub m}, and T{sub f} with a special focus on the evolution of dynamics of PNRs. Portraying high capacitance of shoulder response as compared to the bulk response in M{sup (}f) spectra shows indirectly the presence of highly polarisable entities that persist even above T{sub B} and below T{sub f}. The activation energies extracted from an Arrhenius fit to the relaxation time of both bulk and shoulder response signify different relaxation mechanisms. Further, the value of the stretched exponent β and the scaling behavior study of the M{sup (}f) spectra envisage temperature sensitive dipolar relaxation.

36 MATERIALS SCIENCE↗

Dynamic Data Repartitioning for Load-Balanced Parallel Particle Tracing

We present a novel dynamic load-balancing algorithm based on data repartitioning for parallel particle tracing in flow visualization. Instead of static data assignment, we dynamically repartition the data into blocks and reassign the blocks to processes to balance the workload distribution among the processes. Block repartitioning is performed based on a dynamic workload estimation method that predicts the workload in the flow field on the fly as the input. In our approach, we allow data duplication in the repartitioning, enabling the same data blocks to be assigned to multiple processes. Load balance is achieved by regularly exchanging the blocks (together with the particles in the blocks) among processes according to the output of the data repartitioning. Compared with other load-balancing algorithms, our approach does not need any preprocessing on the raw data and does not require any dedicated process for work scheduling, while it has the capability to balance uneven workload efficiently. Results show improved load balance and high efficiency of our method on tracing particles in both steady and unsteady flow.

data repartitioning↗

Kelvin Probe Force Microscopy in liquid using Electrochemical Force Microscopy

Conventional closed loop-Kelvin probe force microscopy (KPFM) has emerged as a powerful technique for probing electric and transport phenomena at the solid-gas interface. The extension of KPFM capabilities to probe electrostatic and electrochemical phenomena at the solid–liquid interface is of interest for a broad range of applications from energy storage to biological systems. However, the operation of KPFM implicitly relies on the presence of a linear lossless dielectric in the probe-sample gap, a condition which is violated for ionically-active liquids (e.g., when diffuse charge dynamics are present). Here, electrostatic and electrochemical measurements are demonstrated in ionically-active (polar isopropanol, milli-Q water and aqueous NaCl) and ionically-inactive (non-polar decane) liquids by electrochemical force microscopy (EcFM), a multidimensional (i.e., bias- and time-resolved) spectroscopy method. In the absence of mobile charges (ambient and non-polar liquids), KPFM and EcFM are both feasible, yielding comparable contact potential difference (CPD) values. In ionically-active liquids, KPFM is not possible and EcFM can be used to measure the dynamic CPD and a rich spectrum of information pertaining to charge screening, ion diffusion, and electrochemical processes (e.g., Faradaic reactions). EcFM measurements conducted in isopropanol and milli-Q water over Au and highly ordered pyrolytic graphite electrodes demonstrate both sample- and solvent-dependent features. Finally, the feasibility of using EcFM as a local force-based mapping technique of material-dependent electrostatic and electrochemical response is investigated. The resultant high dimensional dataset is visualized using a purely statistical approach that does not require a priori physical models, allowing for qualitative mapping of electrostatic and electrochemical material properties at the solid–liquid interface.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Production of high-quality polyethylene (PE) films from post-consumer shrink wrap with solvent targeted recovery and precipitation (STRAP)

The solvent-targeted recovery and precipitation (STRAP™) process separates polymers from contaminants present in the feedstock. In this work, we demonstrate the recyclability of a post-consumer waste (PCW) shrink wrap that contains inks, adhesives, and paper using STRAP. We produced a clear rPE cast film from the PCR shrink wrap with no visual contamination from paper or inks. STRAP decreased the ash content from 0.96 wt% to 0.24 wt%. A techno-economic analysis (TEA) shows that a STRAP plant processing 50,000 metric tons annually of shrink wrap waste (purchased at $\$0.25$/kg) containing 85 wt% PE can achieve an IRR of 16.2% when selling rPE at $\$1.30$/kg, an IRR of 10.7% with an rPE price of $\$1.00$/kg, or an IRR of 3.79% with an rPE price of $\$0.70$/kg. Furthermore, the life cycle assessment (LCA) shows a 64% reduction in global warming potential (kg CO 2 equivalent) when compared to the production of virgin LDPE. As a result, this work shows how feedstocks with insoluble impurities can be recycled using STRAP on a large scale.

Radkevich, Elizaveta [University of Wisconsin-Madi↗

Nanocomposite formed by titanium ion implantation into alumina

Composites of titanium nanoparticles in alumina were formed by ion implantation of titanium into alumina, and the surface electrical conductivity measured in situ as the implantation proceeded, thus generating curves of sheet conductivity as a function of dose. The implanted titanium self-conglomerates into nanoparticles, and the spatial dimensions of the buried nanocomposite layer can thus be estimated from the implantation depth profile. Rutherford backscattering spectrometry was performed to measure the implantation depth profile, and was in good agreement with the calculated profile. Transmission electron microscopy of the titanium-implanted alumina was used for direct visualization of the nanoparticles formed. The measured conductivity of the buried layer is explained by percolation theory. We determine that the saturation dose, φ{sub 0}, the maximum implantation dose for which the nanocomposite material still remains a composite, is φ{sub 0} = 2.2 × 10{sup 16 }cm{sup −2}, and the corresponding saturation conductivity is σ{sub 0} = 480 S/m. The percolation dose φ{sub c}, below which the nanocomposite still has basically the conductivity of the alumina matrix, was found to be φ{sub c} = 0.84 × 10{sup 16 }cm{sup −2}. The experimental results are discussed and compared with a percolation theory model.

36 MATERIALS SCIENCE↗