Search NASA⌕ Search

SEARCH · Search NASA

Results for “Continuous”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Continuous-flow reactor with superior production rate and stability for CO 2 reduction using semiconductor photocatalysts

Semiconductor photocatalyst approaches for solar CO 2 reduction are attractive due to their simplicity but have lagged in efficiency compared to less-integrated photoelectrochemical (PEC) approaches and to electrolysis reactors. We identify poor mass transport and catalyst deactivation as key constraints. To address them, we have developed a continuous-flow photocatalytic reactor system allowing us to control the triple-phase interface on the photocatalyst surface using the liquid and reactant gas flow rates. With the goal of selectively producing CO, the reactor is optimized by controlling the pressure and flow rates of the reactant gas and electrolyte in contact with both sides with the intermediately placed catalyst. In comparison to batch reactors with an immobile photocatalyst bed and gas phase CO 2 or CO 2 purged water, 10–24 times higher production rates are achieved for photocatalysts such as TiO 2 , ZnO, C 3 N 4 , and CdS by simply changing to the designed flow-type photoreactor without any catalyst modification. In addition, CO selectivity (93.2%) and long-term stability (>780 min) using the designed reactor are significantly enhanced compared to using the batch reactors (71.7%, <180 min for reduced 50% activity). Here, we propose that the enhanced mass transport on the photocatalyst surface accelerates the desorption of the initial photolysis product, CO, and prevents the poisoning effect from deactivating photocatalyst activity. This study has the potential to facilitate the utilization of semiconductor-based photocatalytic reactions for achieving superior performance wih gaseous reactants.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Day-ahead continuous double auction-based peer-to-peer energy trading platform incorporating trading losses and network utilisation fee

Integration of distributed energy resources, such as photovoltaic solar (PV), introduces new opportunities to establish local energy market frameworks to improve renewable energy utilisation in residential sectors. Such peer-to-peer (P2P) energy trading refers to a local market structure where customers (and prosumers) interact to share excess PV generation to enhance the individual and community social welfare. In this work, a day-ahead continuous double auction (CDA)-based P2P market structure considering network losses and network utilisation fees was designed. Day-ahead PV energy is modelled using fractional integral polynomials and the output is forecasted using an autoregressive integrated moving average model for each market interval. Based on the customer load and excess PV energy, the CDA market is cleared using a bid/ask matching mechanism. The performance of the P2P market was evaluated by computing different welfare metrics while analysing the effect of network constraints. The results show that the designed CDA-based P2P market structure increases the social welfare of all participants by an average of 17.75% compared to the baseline for the presented cases. Moreover, the impact of the forecasting error between the day-ahead and real-time market was also quantified.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Continuous Integration Service at Fermilab

This paper describes the current architecture of Continuous Integration (CI) service developed at Fermilab, encountered successes and difficulties, as well as future development plans. The current experiment code has hundreds of contributors that provide new features, bug fixes, and other improvements. Version control systems help developers to collaborate in contributing software for their experiments, while the CI system helps developers keep their code healthy. The Fermilab CI service allows experiments and projects to test and validate their offline production and analysis code on the supported platforms. It is built on top of Jenkins, designed to be set up from a configuration file that provides implementation for each phase of the CI workflow, and able to validate experiment code through grid jobs. This CI service provides a dashboard for easy access to logs and statistical graphs. Since the CI service has been adopted by Fermilab experiments/projects, it proved to be very useful to intercept issues in their code early on and get them fixed before running it in production. Currently the CI service is in use by the ArgoNeuT, DUNE, g-2, LArIAT, MINERvA, mu2e, NOvA, SBND and uBooNE experiments and by the following projects: ART and LArSoft software suites, GENIE, and Glidein-WMS. The CI service is under active development and planning to support code profiling.

Di benedetto, Vito↗

Effect of film texture on magnetization reversal and switching field in continuous and patterned (Co/Pd) multilayers

We studied the reversal properties of perpendicular anisotropy (Co/Pd) multilayers with different crystallographic textures. In case of continuous films, an increase in the coercivity and reduction in the switching field distribution (SFD) were observed as the growth is improved. From magnetic force microscopy, a stripe-type domain configuration was observed in films deposited at low gas pressure while a bubble-type domain was observed in high pressure deposited films. In patterned films, the SFD did not vary significantly for samples with different textures although a 2 kOe increase in the switching field was measured. In patterned structures, the controllability of SFD may not be related to the improvement of film crystallographic growth as was observed for unpatterned films. The results from this study indicate that local variation in the intrinsic film properties plays a major role in the SFD.

36 MATERIALS SCIENCE↗

Quantum regression formula and luminescence spectra of two coupled modes under incoherent continuous pumping

We study the quantum regression formula for two coupled dissipative modes in the steady state under incoherent continuous pumping. We analyze the equations for one and two-time correlators, needed to compute the spectra of emission of the system, for two coupled harmonic oscillators (linear model), on the one hand, and two coupled two-level systems, on the other hand. We present a comparison between them, on the basis of fully analytical results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Off-axis stability of intense continuous relativistic beams

This paper investigates the stability of off-axis continuous intense relativistic beams propagating inside a circular conducting pipe. The equations of motion for the centroid and the envelope of slightly off-axis beams are derived and used to determine equilibrium and stability conditions for the beam transport. It is shown that depending on the parameters of the system, beams propagating along the pipe axis may become unstable due to the presence of the wall, imposing a fundamental limitation in the effective area that an equilibrium beam can occupy inside the conductor.

43 PARTICLE ACCELERATORS↗

3 W continuous-wave room temperature single-facet emission from quantum cascade lasers based on nonresonant extraction design approach

A strain-balanced, InP-based quantum cascade laser structure, designed for light emission at 4.6 {mu}m using a new nonresonant extraction design approach, was grown by molecular beam epitaxy. Removal of the restrictive two-phonon resonant condition, currently used in most structure designs, allows simultaneous optimization of several design parameters influencing laser performance. Following the growth, the structure was processed in buried heterostructure. Maximum single-ended continuous-wave optical power of 3 W was obtained at 293 K for devices with stripe dimensions of 5 mmx11.6 {mu}m. Corresponding maximum wallplug efficiency and threshold current density were measured to be 12.7% and 0.86 kA/cm{sup 2}.

36 MATERIALS SCIENCE↗

Continuous wavelet transform based time-scale and multifractal analysis of the nonlinear oscillations in a hollow cathode glow discharge plasma

Continuous wavelet transform (CWT) based time-scale and multifractal analyses have been carried out on the anode glow related nonlinear floating potential fluctuations in a hollow cathode glow discharge plasma. CWT has been used to obtain the contour and ridge plots. Scale shift (or inversely frequency shift), which is a typical nonlinear behavior, has been detected from the undulating contours. From the ridge plots, we have identified the presence of nonlinearity and degree of chaoticity. Using the wavelet transform modulus maxima technique we have obtained the multifractal spectrum for the fluctuations at different discharge voltages and the spectrum was observed to become a monofractal for periodic signals. These multifractal spectra were also used to estimate different quantities such as the correlation and fractal dimension, degree of multifractality, and complexity parameters. These estimations have been found to be consistent with the nonlinear time series analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of analytically capable time-of-flight mass spectrometer with continuous ion introduction

The present article describes the results and findings explored in the course of the development of the analytically capable prototype of continuous time-of-flight (CTOF) mass spectrometer. Currently marketed pulsed TOF (PTOF) instruments use ion introduction with a 10 ns or so pulse width, followed by a waiting period roughly 100 {mu}s. Accordingly, the sample is under excitation in 10{sup -4} part of the total measuring time. This very low duty cycle severely limits the sensitivity of the PTOF method. A possible approach to deal with this problem is to use linear sinusoidal dual modulation technique (CTOF) as described in this article. This way the sensitivity of the method is increased, due to the 50% duty cycle of the excitation. All other types of TOF spectrometer use secondary electron multiplier (SEM) for detection, which unfortunately discriminates in amplification in favor of the lighter ions. This discrimination effect is especially undesirable in a mass spectrometric method, which targets high mass range. In CTOF method, SEM is replaced with Faraday cup detector, thus eliminating the mass discrimination effect. Omitting SEM is made possible by the high ion intensity and the very slow ion detection with some hundred hertz detection bandwidth. The electrometer electronics of the Faraday cup detector operates with amplification 10{sup 10} V/A. The primary ion beam is highly monoenergetic due to the construction of the ion gun, which made possible to omit any electrostatic mirror configuration for bunching the ions. The measurement is controlled by a personal computer and the intelligent signal generator Type Tabor WW 2571, which uses the direct digital synthesis technique for making arbitrary wave forms. The data are collected by a Labjack interface board, and the fast Fourier transformation is performed by the software. Noble gas mixture has been used to test the analytical capabilities of the prototype setup. Measurement presented proves the results of the mathematical calculations as well as the future potentiality for use in chemical analysis of gaseous mixtures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetoelectric effect in lead-free BNKLBT ceramic/terfenol-D continue fiber composite laminates

A magnetostrictive-piezoelectric laminated composite has been developed by sandwiching a lead-free BNKLBT ceramic plate polarized in the thickness direction between two terfenol-D continuous fiber composite plates. This lead-free magnetoelectric (ME) laminated composite has a large ME voltage sensitivity of 2.5 V/Oe at the resonance frequency of 130.9 kHz under a low magnetic bias field (H{sub Bias}) of 0.6 kOe. This work shows the potential of BNKLBT lead-free ceramics in ME sensing application.

36 MATERIALS SCIENCE↗