Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data fitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Metastable phase of UTe 2 formed under high pressure above 5 GPa

Uranium ditelluride (UTe 2 ) has attracted recent interest due to its unique superconducting properties, which include the potential for a topological odd-parity superconducting state. Recently, ac-calorimetry measurements under pressure indicate a change in the ground state of UTe 2 from superconducting to antiferromagnetic at 1.4 GPa. In this work, we investigate the effect of pressure on the crystal structure of UTe 2 up to 25 GPa at room temperature using x-ray diffraction. We find that UTe 2 , which at ambient conditions has an orthorhombic (Immm) structure, transforms to a body-centered tetragonal (I4/mmm) structure at 5 GPa in a quasihydrostatic neon (Ne) pressure-transmitting medium. In the absence of a pressure-transmitting medium, this transformation occurs between 5 and 8 GPa. The data were fit with a third-order Birch-Murnaghan equation of state resulting in values of B 0 = 46.0 ± 0.6 GPa , B' = 9.3 ± 0.5 (no pressure medium), and B 0 = 42.5 ± 2.0 GPa , B' = 9.3 (fixed) (neon pressure medium) for the Immm phase. For the I4/mmm phase, B 0 = 78.9 ± 0.5 GPa GPa and B' = 4.2 ± 0.1 (no pressure-transmitting medium), and B 0 = 70.0 ± 1.1 GPa and B' = 4.1 ± 0.2 (neon pressure medium). The high-pressure tetragonal phase is retained after decompression to ambient pressure, with approximately 30% remaining after 2 days. We argue that the observed phase transition into a higher-symmetry structure at P ~ 5 GPa (orthorhombic to tetragonal) is accompanied by an increase in the shortest distance between uranium atoms from 3.6 Å (orthorhombic) to 3.9 Å (tetragonal), which suggests localization of the 5ƒ electrons, albeit with a 10.7% decrease in volume.

36 MATERIALS SCIENCE↗

Anisotropic magnetism of the Shastry-Sutherland lattice material BaNd 2 PtO 5

For this work, single crystals were grown and characterized to investigate the physical properties and magnetic ground state of BaNd 2 PtO 5 , a candidate to host physics of the Shastry-Sutherland model. Analysis of single crystal x-ray diffraction data yields an updated crystal structure, similar to the prior report but now in space group P4/mbm. Magnetization and specific heat measurements reveal an antiferromagnetic transition at T N =1.9K and a large magnetic anisotropy with in-plane magnetization much larger than out-of-plane magnetization. Single crystal neutron diffraction at zero field reveals a propagation vector of ($\frac{1}{2}$$\frac{1}{2}$$\frac{1}{2}$) for the magnetic ground state as compared to the ($\frac{1}{2}$$\frac{1}{2}$0) wave vector observed in the related body-centered material BaNd 2 ZnO 5 . The ground state is found to be a fully compensated antiferromagnet with diffraction data well fitted within the magnetic space group P S –1 (BNS setting #2.7). The ordered moment is mostly in the basal plane with nearest neighbors forming ferromagnetic dimers, however it also has a finite out-of-plane component unlike the related easy-plane materials BaNd 2 ZnO 5 and BaNd 2 ZnS 5 . Field-induced transitions are observed below T N when the field is applied within the basal plane, and in-plane anisotropy of the associated critical fields is observed. The magnetization is strongly impacted by misalignment of the field away from high symmetry directions. These results suggest complex magnetic structures may arise in the field-induced states, and they highlight the need for extreme care when studying this and related Shastry-Sutherland materials.

36 MATERIALS SCIENCE↗

The Heuristic Static Load-Balancing Algorithm Applied to the Community Earth System Model

We propose to use the heuristic static loadbalancing (HSLB) algorithm for solving load-balancing problems in the Community Earth System Model (CESM), a climate model, using fitted benchmark data as an alternative to the current manual approach. The problem of allocating the optimal number of CPU cores to CESM components is formulated as a mixed-integer nonlinear optimization problem which is solved by using an optimization branch-and-bound solver implemented in the MINLP package MINOTAUR. The key feature of the branch-and- bound method is that it guarantees to provide an optimal solution or show that none exists. Our algorithm was tested for the 1 degrees and 1/8 degrees resolution simulations on 32,768 nodes (131,072 cores) of IBM Blue Gene/P where we consistently achieved well load-balanced results. This work is a part of a broader effort to eliminate the need for manual tuning of the code for each platform and simulation type, improve the performance and scalability of CESM, and develop automated tools to achieve these goals.

Alekseev, Yury↗

Thermal Conductivity Measurement of Extrusion-Printed Silver Using Modulated Photothermal Radiometry

Flexible printed electronics is a rapidly growing field with applications in conformal and flexible devices. However, the physical properties of the films created by many state-of-the-art printing methods become highly dependent on printing parameters, resulting in varying thermal properties often differing significantly from their bulk ink components. To understand the influence of the printing process, we build upon our previous work, where a noncontact optical technique, known as modulated photothermal radiometry (MPTR), was used to measure the thermal conductivity of aerosol-jet-printed thin films. In this work, we use the method to study the thermal properties of extrusion-printed silver on glass and alumina substrates. A noise-resistant data analysis fitting technique is applied using a 2-D heat transfer model. Here, the thermal conductivity measurement is validated using the Weidemann-Franz (WF) relationship from measured electrical conductivity values.

42 ENGINEERING↗

Cracked Gridline Wear Out Follows a Power Law

Cracks can form in Silicon solar cells in photovoltaic modules due to mechanical stresses arising from various extrinsic factors like handling and weather. While the immediate performance degradation may be minor, continuous loading overtime will degrade module performance. One probable reason is gridline surface wear across the cracked silicon with increased cyclic loading. In this work we propose a method to correlate gridline wear to module electrical degradation. We begin by conducting cyclic four-point bending tests on laminated silicon solar cells with a single crack and 22 intact gridlines for 10,000 cycles. We measure the progressive change in resistance during each loading cycle. We correlate it to a length scale called critical crack opening displacement (CCOD) that signifies failure of individual gridlines. By employing Weibull analysis, we determine the characteristic CCOD for all cycles and fit this data to a modified version of a wear power law. We observe that this i ts the data well. We also propose to study the effect of individual parameters in the power law equation and extend the equation to include material properties.

bending↗

Nonproportionality of Scintillator Detectors. III. Temperature Dependence Studies

This paper is the third in a series of articles on the basic physics of nonproportionality in scintillators. In this work, we focus on the temperature dependence of six scintillators, NaI(Tl), CsI(Tl), CsI(Na), CeBr 3 , LaBr 3 (Ce), and undoped SrI 2 , and report their nonproportionality curves at -40 °C, 0 °C and +40 °C. We fit the data to a modified form of our previously employed model, including the competition of carrier trapping with the Onsager-mediated attraction between electrons and holes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nitrogen increases early‐stage and slows late‐stage decomposition across diverse grasslands

1. To evaluate how increased anthropogenic nutrient inputs alter carbon cycling in grasslands, we conducted a litter decomposition study across 20 temperate grasslands on three continents within the Nutrient Network, a globally distributed nutrient enrichment experiment 2. We determined the effects of addition of experimental nitrogen (N), phosphorus (P) and potassium plus micronutrient (K μ ) on decomposition of a common tree leaf litter in a long-term study (maximum of 7 years; exact deployment period varied across sites). The use of higher order decomposition models allowed us to distinguish between the effects of nutrients on early- versus late-stage decomposition. 3. Across continents, the addition of N (but not other nutrients) accelerated early-stage decomposition and slowed late-stage decomposition, increasing the slowly decomposing fraction by 28% and the overall litter mean residence time by 58%. 4. Synthesis. Using a novel, long-term cross-site experiment, we found widespread evidence that N enhances the early stages of above-ground plant litter decomposition across diverse and widespread temperate grassland sites but slows late-stage decomposition. These findings were corroborated by fitting the data to multiple decomposition models and have implications for N effects on soil organic matter formation. For example, following N enrichment, increased microbial processing of litter substrates early in decomposition could promote the production and transfer of low molecular weight compounds to soils and potentially enhance the stabilization of mineral-associated organic matter. By contrast, by slowing late-stage decomposition, N enrichment could promote particulate organic matter (POM) accumulation. Such hypotheses deserve further testing.

Nutrient Network (NutNet)↗

The Predictive Power of Electronic Polarizability for Tailoring the Refractivity of High Index Glasses Optical Basicity Versus the Single Oscillator Model

Four compositions of high density (~8 g/cm3) heavy metal oxide glasses composed of PbO, Bi2O3, and Ga2O3 were produced and refractivity parameters (refractive index and density) were computed and measured. Optical basicity was computed using three different models – average electronegativity, ionic-covalent parameter, and energy gap – and the basicity results were used to compute oxygen polarizability and subsequently refractive index. Refractive indices were measured in the visible and infrared at 0.633 μm, 1.55 μm, 3.39 μm, 5.35 μm, 9.29 μm, and 10.59 μm using a unique prism coupler setup, and data were fitted to the Sellmeier expression to obtain an equation of the dispersion of refractive index with wavelength. Using this dispersion relation, single oscillator energy, dispersion energy, and lattice energy were determined. Oscillator parameters were also calculated for the various glasses from their oxide values as an additional means of predicting index. Calculated dispersion parameters from oxides underestimate the index by 3 to 4%. Predicted glass index from optical basicity, based on component oxide energy gaps, underpredicts the index at 0.633 μm by only 2%, while other basicity scales are less accurate. The predicted energy gap of the glasses based on this optical basicity overpredicts the Tauc optical gap as determined by transmission measurements by 6 to 10%. These results show that for this system, density, refractive index in the visible, and energy gap can be reasonably predicted using only composition, optical basicity values for the constituent oxides, and partial molar volume coefficients. Calculations such as these are useful for a priori prediction of optical properties of glasses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Combined Computational and Mathematical Analysis of Interconnect Fatigue Potential in Photovoltaic Modules

A finite element model of a 60-cell monocrystalline silicon glass-polymer photovoltaic module was simulated with ±1.0 kPa and ±2.4 kPa loads applied to the glass to calculate the deformation under load. Cell-to-cell displacements were used to approximate interconnect strain and stress. A mathematical fatigue cycle life relation was fitted to data for the interconnect material (copper), to generate a life prediction at each interconnect location based on the local stress means, reversal extents, and amplitudes. Interconnect stress was found to be significantly asymmetric about zero despite symmetric positive and negative module loads due to laminate thickness offsets about the neutral plane and the effects of module framing. Cycle life results indicated that interconnect fatigue failure was unlikely to occur over a 30-year lifetime of conservative wind and snow load cycles since the typical cell design feature of leaving some unconstrained length between the cell edge and first solder pad increases the effective gauge length and decreases the stress levels below the material endurance limit. Follow-up analyses found that 3.6 mm and 6.4 mm were the minimum unconstrained lengths required to survive the assumed lifetime of wind and snow cycles, respectively, confirming that typical industrial module constructions with 8–15 mm unconstrained lengths should survive conservatively. Notably, large magnitude, low-cycle snow loading was consistently the limiting factor requiring a longer unconstrained interconnect length. Finally, insights and workflows from this study inform module interconnection design limits for survival against mechanical fatigue in deployment environments.

14 SOLAR ENERGY↗

Pressure Drop as a Function of Air Flow Rate for Roll-Punched Transpired Solar Collectors With Different Porosities

Transpired solar collectors are simple and cost-effective devices suited for preheating ventilation air for buildings. They work by drawing outside air through a south-facing perforated metal absorber. The absorber is heated by solar radiation, heat is transferred to the air as it is drawn through the perforations in the absorber, and the pre-heated air is delivered to the building. Oftenoverlooked in the design of transpired collector systems is the effect on collector efficiency of pressure drop across the absorber. The pressure drop is a function of the air flow rate through the perforations, the overall porosity of the absorber, and the properties of the air. The National Renewable Energy Laboratory (NREL) conducted a series of laboratory tests to characterize the pressuredrop as a function of the relevant parameters for six commercially-available absorber configurations; three porosities in aluminum and three in steel. Each absorber material is roll-punched to one of three depths to create absorbers with three different porosities. Pressure drop, air flow rate, air temperature, and air relative humidity data were collected during the tests. The data were fit toa model that can be used to predict pressure drop across the absorber as a function of air properties and flow rate. Use of these correlations is expected to aid designers in ensuring that transpired collector systems are designed for optimal thermal efficiency and cost effectiveness.

14 SOLAR ENERGY↗

Dose rate profile surrounding a repository

The focus of this research was to analyze the dose rate profile around a waste repository using Monte Carlo techniques. Dose rates at various heights and distances were analyzed outside of the waste repository using MCNPX [1]. The heights measured extended the height of the building and the distances varied between 0 and 22 m away from the waste repository. The simulation data were fitted by smooth analytical functions for different height levels and distances, such that vertical and horizontal dose rates as functions of source-detector distance were achieved. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of 20 nm silver nanoparticles synthesized with and without a gold core. Structure, dissolution in cell culture media, and biological impact on macrophages

Widespread use of silver nanoparticles raises questions of environmental impact and toxicity. Both silver particles and silver ions formed by particle dissolution may impact biological systems. Therefore it is important to understand the characteristics of silver nanoparticles and their stability in relevant media. The synthesis route can impact physical and chemical characteristics of the particles and we report the characterization and solution stability of three types of silver nanoparticles (20 nm particles with and without gold cores and 110 nm particles with gold cores) in cell culture media with serum proteins: FBS10%/RPMI. These nanoparticles were synthesized in aqueous solution and characterized using both in situ and ex situ analysis methods. Dissolution studies were carried at particle concentrations from 1 µg/ml to 50 µg/ml. Particles with gold cores had smaller crystallite size and higher apparent solubility than pure silver particles. A dissolution model was found to describe the time variation of particle size and amount of dissolved silver for particle loadings above 9 µg/ml. An effective solubility product obtained from fitting the data was higher for the 20 nm gold core particles in comparison to the pure silver or 110 nm particles. Dissolution of the nanoparticles was enhanced by presence of serum proteins contained in fetal bovine serum. In addition, the protocol of the dispersion in the medium was found to influence particle agglomeration and dissolution. Results show that particle structure can impact the concentration of dissolved silver and the dose to which cells would be exposed during in vitro studies.

59 BASIC BIOLOGICAL SCIENCES↗

Comparing Exciton-Polariton Couplings in Two-Dimensional MoS2 Cavities

Exciton-polaritons (EPs) are an emerging approach to achieve strong light-matter coupling and robust quantum phenomena, with application to areas such as photonic neuromorphic computing for instance reservoir computing. 2D transition metal dichalcogenides (TMDs) are promising candidates to host EPs due to their potential for strong coupling as evidenced by large Rabi splitting energies, which in the case of few-layer MoS2 has been demonstrated to reach 293 meV when coupled to the C exciton, placing it in the ultrastrong coupling regime, at room temperature. Here we examine how the Rabi splitting of CVD-grown monolayer MoS2 in a cavity can be optimized by tuning two variables: cavity geometry (thickness of silver and dielectric spacers) and the targeted exciton for coupling (A at about 1.9 eV, B at about 2.06 eV, or C at about 2.9 eV). With the cavity geometry, there is a tradeoff between optical field confinement and transmission. With the targeted exciton, there may be a tradeoff between Rabi splitting and lifetime. Transfer matrix simulations are used to inform how thick the cavity layers need to be, and at what angle measurements should be performed, to achieve Rabi splitting at a certain exciton energy. Experimentally, the Rabi splitting is measured by placing the cavity at a specified angle and measuring the optical reflectance and transmittance. By fitting the data, we find Rabi splittings of 124 meV, 194 meV, and 288 meV for the A, B, and C excitons, respectively, which places them in the strong, and on the edge of the ultrastrong, coupling regime.

exciton-polaritons↗

Apparent absence of a proton beam dose rate effect and possible differences in RBE between Bragg peak and plateau

Purpose: Respiration-gated irradiation for a moving target requires a longer time to deliver single fraction in proton radiotherapy (PRT). Ultrahigh dose rate (UDR) proton beam, which is 10-100 times higher than that is used in current clinical practice, has been investigated to deliver daily dose in single breath hold duration. The purpose of this study is to investigate the survival curve and relative biological effectiveness (RBE) of such an ultrahigh dose rate proton beam and their linear energy transfer (LET) dependence. Methods: HSG cells were irradiated by a spatially and temporally uniform proton beam at two different dose rates: 8 Gy/min (CDR, clinical dose rate) and 325 Gy/min (UDR, ultrahigh dose rate) at the Bragg peak and 1.75 (CDR) and 114 Gy/min (UDR) at the plateau. To study LET dependence, the cells were positioned at the Bragg peak, where the absorbed dose-averaged LET was 3.19 keV/{mu}m, and at the plateau, where it was 0.56 keV/{mu}m. After the cell exposure and colony assay, the measured data were fitted by the linear quadratic (LQ) model and the survival curves and RBE at 10% survival were compared. Results: No significant difference was observed in the survival curves between the two proton dose rates. The ratio of the RBE for CDR/UDR was 0.98{+-}0.04 at the Bragg peak and 0.96{+-}0.06 at the plateau. On the other hand, Bragg peak/plateau RBE ratio was 1.15{+-}0.05 for UDR and 1.18{+-}0.07 for CDR. Conclusions: Present RBE can be consistently used in treatment planning of PRT using ultrahigh dose rate radiation. Because a significant increase in RBE toward the Bragg peak was observed for both UDR and CDR, further evaluation of RBE enhancement toward the Bragg peak and beyond is required.

60 APPLIED LIFE SCIENCES↗

SU-E-QI-11: Measurement of Renal Pyruvate-To-Lactate Exchange with Hyperpolarized 13C MRI

Purpose: Previous work [1] modeling the metabolic flux between hyperpolarized [1-13C]pyruvate and [1-13C]lactate in magnetic resonance spectroscopic imaging (MRSI) experiments failed to account for vascular signal artifacts. Here, we investigate a method to minimize the vascular signal and its impact on the fidelity of metabolic modeling. Methods: MRSI was simulated for renal metabolism in MATLAB both with and without bipolar gradients. The resulting data were fit to a two-site exchange model [1], and the effects of vascular partial volume artifacts on kinetic modeling were assessed. Bipolar gradients were then incorporated into a gradient echo sequence to validate the simulations experimentally. The degree of diffusion weighting (b = 32 s/mm{sup 2}) was determined empirically from 1H imaging of murine renal vascular signal. The method was then tested in vivo using MRSI with bipolar gradients following injection of hyperpolarized [1-{sup 13}C]pyruvate (∼80 mM at 20% polarization). Results: In simulations, vascular signal contaminated the renal metabolic signal at resolutions as high as 2 × 2 mm{sup 2} due to partial volume effects. The apparent exchange rate from pyruvate to lactate (k{sub p}) was underestimated in the presence of these artifacts due to contaminating pyruvate signal. Incorporation of bipolar gradients suppressed vascular signal and improved the accuracy of kp estimation. Experimentally, the in vivo results supported the ability of bipolar gradients to suppress vascular signal. The in vivo exchange rate increased, as predicted in simulations, from k{sub p} = 0.012 s-{sup 1} to k{sub p} = 0.020-{sup 1} after vascular signal suppression. Conclusion: We have demonstrated the limited accuracy of the two-site exchange model in the presence of vascular partial volume artifacts. The addition of bipolar gradients suppressed vascular signal and improved model accuracy in simulations. Bipolar gradients largely affected kp estimation in vivo. Currently, slow-flowing spins in small vessels and capillaries are only partially suppressed, so further improvement is possible. Funding support: Seed Grant from the Radiological Society of North America, GE Healthcare, University of Wisconsin Graduate School.

60 APPLIED LIFE SCIENCES↗

SU-E-QI-14: Quantitative Variogram Detection of Mild, Unilateral Disease in Elastase-Treated Rats

Purpose: Determining the presence of mild or early disease in the lungs can be challenging and subjective. We present a rapid and objective method for evaluating lung damage in a rat model of unilateral mild emphysema based on a new approach to heterogeneity assessment. We combined octree decomposition (used in three-dimensional (3D) computer graphics) with variograms (used in geostatistics to assess spatial relationships) to evaluate 3D computed tomography (CT) lung images for disease. Methods: Male, Sprague-Dawley rats (232 ± 7 g) were intratracheally dosed with 50 U/kg of elastase dissolved in 200 μL of saline to a single lobe (n=6) or with saline only (n=5). After four weeks, 3D micro-CT images were acquired at end expiration on mechanically ventilated rats using prospective gating. Images were masked, and lungs were decomposed to homogeneous blocks of 2×2×2, 4×4×4, and 8×8×8 voxels using octree decomposition. The spatial variance – the square of the difference of signal intensity – between all pairs of the 8×8×8 blocks was calculated. Variograms – graphs of distance vs. variance - were made, and data were fit to a power law and the exponent determined. The mean HU values, coefficient of variation (CoV), and the emphysema index (EI) were calculated and compared to the variograms. Results: The variogram analysis showed that significant differences between groups existed (p<0.01), whereas the mean HU (p=0.07), CoV (p=0.24), and EI (p=0.08) did not. Calculation time for the variogram for a typical 1000 block decomposition was ∼6 seconds, and octree decomposition took ∼2 minutes. Decomposing the images prior to variogram calculation resulted in a ∼700x decrease in time as compared to other published approaches. Conclusions: Our results suggest that the approach combining octree decomposition and variogram analysis may be a rapid, non-subjective, and sensitive imaging-based biomarker for quantitative characterization of lung disease.

60 APPLIED LIFE SCIENCES↗

TU-A-12A-09: Absolute Blood Flow Measurement in a Cardiac Phantom Using Low Dose CT

Purpose: To investigate a first pass analysis technique to measure absolute flow from low dose CT images in a cardiac phantom. This technique can be combined with a myocardial mass assignment to yield absolute perfusion using only two volume scans and reduce the radiation dose to the patient. Methods: A four-chamber cardiac phantom and perfusion chamber were constructed from poly-acrylic and connected with tubing to approximate anatomical features. The system was connected to a pulsatile pump, input/output reservoirs and power contrast injector. Flow was varied in the range of 1-2.67 mL/s with the pump operating at 60 beats/min. The system was imaged once a second for 14 seconds with a 320-row scanner (Toshiba Medical Systems) using a contrast-enhanced, prospective-gated cardiac perfusion protocol. Flow was calculated by the following steps: subsequent images of the perfusion volume were subtracted to find the contrast entering the volume; this was normalized by an upstream, known volume region to convert Hounsfield (HU) values to concentration; this was divided by the subtracted images time difference. The technique requires a relatively stable input contrast concentration and no contrast can leave the perfusion volume before the flow measurement is completed. Results: The flow calculated from the images showed an excellent correlation with the known rates. The data was fit to a linear function with slope 1.03, intercept 0.02 and an R{sup 2} value of 0.99. The average root mean square (RMS) error was 0.15 mL/s and the average standard deviation was 0.14 mL/s. The flow rate was stable within 7.7% across the full scan and served to validate model assumptions. Conclusion: Accurate, absolute flow rates were measured from CT images using a conservation of mass model. Measurements can be made using two volume scans which can substantially reduce the radiation dose compared with current dynamic perfusion techniques.

60 APPLIED LIFE SCIENCES↗