Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data reduction methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Risk of Secondary Malignant Neoplasms From Proton Therapy and Intensity-Modulated X-Ray Therapy for Early-Stage Prostate Cancer

Purpose: To assess the risk of a secondary malignant neoplasm (SMN) from proton therapy relative to intensity-modulated radiation therapy (IMRT) using X-rays, taking into account contributions from both primary and secondary sources of radiation, for prostate cancer. Methods and Materials: A proton therapy plan and a 6-MV IMRT plan were constructed for 3 patients with early-stage adenocarcinoma of the prostate. Doses from the primary fields delivered to organs at risk of developing an SMN were determined from treatment plans. Secondary doses from the proton therapy and IMRT were determined from Monte Carlo simulations and available measured data, respectively. The risk of an SMN was estimated from primary and secondary doses on an organ-by-organ basis by use of risk models from the Committee on the Biological Effects of Ionizing Radiation. Results: Proton therapy reduced the risk of an SMN by 26% to 39% compared with IMRT. The risk of an SMN for both modalities was greatest in the in-field organs. However, the risks from the in-field organs were considerably lower with the proton therapy plan than with the IMRT plan. This reduction was attributed to the substantial sparing of the rectum and bladder from exposure to the therapeutic beam by the proton therapy plan. Conclusions: When considering exposure to primary and secondary radiation, proton therapy can reduce the risk of an SMN in prostate patients compared with contemporary IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficient hybrid explicit-implicit learning for multiscale problems

Splitting method is a powerful method to handle application problems by splitting physics, scales, domain, and so on. Many splitting algorithms have been designed for efficient temporal discretization. Here, in this paper, our goal is to use temporal splitting concepts in designing machine learning algorithms and, at the same time, help splitting algorithms by incorporating data and speeding them up. We propose a machine learning assisted splitting scheme which improves the efficiency of the scheme meanwhile preserves the accuracy. We consider a recently introduced multiscale splitting algorithms, where the multiscale problem is solved on a coarse grid. To approximate the dynamics, only a few degrees of freedom are solved implicitly, while others explicitly. This splitting concept allows identifying degrees of freedom that need implicit treatment. In this paper, we use this splitting concept in machine learning and propose several strategies. First, the implicit part of the solution can be learned as it is more difficult to solve, while the explicit part can be computed. This provides a speed-up and data incorporation for splitting approaches. Secondly, one can design a hybrid neural network architecture because handling explicit parts requires much fewer communications among neurons and can be done efficiently. Thirdly, one can solve the coarse grid component via PDEs or other approximation methods and construct simpler neural networks for the explicit part of the solutions. We discuss these options and implement one of them by interpreting it as a machine translation task. This interpretation of the splitting scheme successfully enables us using the Transformer since it can perform model reduction for multiple time series and learn the connection between them. We also find that the splitting scheme is a great platform to predict the coarse solution with insufficient information of the target model: the target problem is partially given and we need to solve it through a known problem which approximates the target. Our machine learning model can incorporate and encode the given information from two different problems and then solve the target problems. We conduct four numerical examples and the results show that our method is stable and accurate.

97 MATHEMATICS AND COMPUTING↗

Synthesis, characterization, and properties of reduced europium molybdates and tungstates

Single crystals of K{sub 0.094}Eu{sub 0.906}MoO{sub 4}, K{sub 0.097}Eu{sub 0.903}WO{sub 4}, EuWO{sub 4}, and EuMoO{sub 4} were grown from molten chloride fluxes contained in vacuum-sealed fused silica and structurally characterized via single crystal X-ray diffraction. The in situ reduction of Eu{sup 3+} to Eu{sup 2+} was carried out using Mo, W, and Zn as metal reducing agents. All four compounds crystallize in the tetragonal space group of I4{sub 1}/a and adopt the scheelite (CaWO{sub 4}) structure type. The magnetic susceptibility of the reported compounds shows paramagnetic behavior down to 2 K. {sup 151}Eu Mössbauer spectroscopy was used to analyze the relative Eu{sup 2+} and Eu{sup 3+} content of the samples. All the compounds were further characterized by EPR, and UV-vis spectroscopy. - Graphical abstract: TOC Caption Two new reduced europium containing quaternary oxides, K{sub 0.094}Eu{sub 0.906}MoO{sub 4} and K{sub 0.097}Eu{sub 0.903}WO{sub 4}, and two previously reported ternary reduced oxides, EuWO{sub 4} and EuMoO{sub 4}, were synthesized via an in situ reduction of Eu{sup 3+} to Eu{sup 2+} under flux method using Mo, W, and Zn as metal reducing agents. {sup 151}Eu Mössbauer spectroscopy was used to analyze the relative Eu{sup 2+} and Eu{sup 3+} content of the samples. - Highlights: • K{sub 0.094}Eu{sub 0.906}MoO{sub 4}, K{sub 0.097}Eu{sub 0.903}WO{sub 4}, EuWO{sub 4}, and EuMoO{sub 4} have been synthesized and characterized. • The in situ reduction of Eu{sup 3+} to Eu{sup 2+} was carried out using Mo, W, and Zn as metal reducing agents. • Magnetic susceptibility data were collected. • {sup 151}Eu Mössbauer spectroscopy was used to analyze Eu{sup 2+} and Eu{sup 3+} content.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The simplest equivalent circuit of a pulsed dielectric barrier discharge and the determination of the gas gap charge transfer

The concept of the simplest equivalent circuit for a dielectric barrier discharge (DBD) is critically reviewed. It is shown that the approach is consistent with experimental data measured either in large-scale sinusoidal-voltage driven or miniature pulse-voltage driven DBDs. An expression for the charge transferred through the gas gap q(t) is obtained with an accurate account for the displacement current and the values of DBD reactor capacitance. This enables (i) the significant reduction of experimental error in the determination of q(t) in pulsed DBDs, (ii) the verification of the classical electrical theory of ozonizers about maximal transferred charge q{sub max}, and (iii) the development of a graphical method for the determination of q{sub max} from charge-voltage characteristics (Q-V plots, often referred as Lissajous figures) measured under pulsed excitation. The method of graphical presentation of q{sub max} is demonstrated with an example of a Q-V plot measured under pulsed excitation. The relations between the discharge current j{sub R}(t), the transferred charge q(t), and the measurable parameters are presented in new forms, which enable the qualitative interpretation of the measured current and voltage waveforms without the knowledge about the value of the dielectric barrier capacitance C{sub d}. Whereas for quantitative evaluation of electrical measurements, the accurate estimation of the C{sub d} is important.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discovering invariant spatial features in electron energy loss spectroscopy images on the mesoscopic and atomic levels

Over the last two decades, Electron Energy Loss Spectroscopy (EELS) imaging with a scanning transmission electron microscope has emerged as a technique of choice for visualizing complex chemical, electronic, plasmonic, and phononic phenomena in complex materials and structures. The availability of the EELS data necessitates the development of methods to analyze multidimensional data sets with complex spatial and energy structures. Traditionally, the analysis of these data sets has been based on analysis of individual spectra, one at a time, whereas the spatial structure and correlations between individual spatial pixels containing the relevant information of the physics of underpinning processes have generally been ignored and analyzed only via the visualization as 2D maps. Here, we develop a machine learning-based approach and workflows for the analysis of spatial structures in 3D EELS data sets using a combination of dimensionality reduction and multichannel rotationally invariant variational autoencoders. This approach is illustrated for the analysis of both the plasmonic phenomena in a system of nanowires and in the core excitations in functional oxides using low loss and core-loss EELS, respectively. The code developed in this manuscript is open sourced and freely available and provided as a Jupyter notebook for the interested reader.

36 MATERIALS SCIENCE↗

Cosmological constraints from Sunyaev-Zeldovich cluster counts: An approach to account for missing redshifts

The accumulation of redshifts provides a significant observational bottleneck when using galaxy cluster surveys to constrain cosmological parameters. We propose a simple method to allow the use of samples where there is a fraction of the redshifts that are not known. The simplest assumption is that the missing redshifts are randomly extracted from the catalog, but the method also allows one to take into account known selection effects in the accumulation of redshifts. We quantify the reduction in statistical precision of cosmological parameter constraints as a function of the fraction of missing redshifts for simulated surveys, and also investigate the impact of making an incorrect assumption for the distribution of missing redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

Decoding the shift-invariant data: applications for band-excitation scanning probe microscopy *

A shift-invariant variational autoencoder (shift-VAE) is developed as an unsupervised method for the analysis of spectral data in the presence of shifts along the parameter axis, disentangling the physically-relevant shifts from other latent variables. Using synthetic data sets, we show that the shift-VAE latent variables closely match the ground truth parameters. The shift VAE is extended towards the analysis of band-excitation piezoresponse force microscopy data, disentangling the resonance frequency shifts from the peak shape parameters in a model-free unsupervised manner. The extensions of this approach towards denoising of data and model-free dimensionality reduction in imaging and spectroscopic data are further demonstrated. This approach is universal and can also be extended to analysis of x-ray diffraction, photoluminescence, Raman spectra, and other data sets.

36 MATERIALS SCIENCE↗

Nonclassicality thresholds for multiqubit states: Numerical analysis

States that strongly violate Bell's inequalities are required in many quantum-informational protocols as, for example, in cryptography, secret sharing, and the reduction of communication complexity. We investigate families of such states with a numerical method which allows us to reveal nonclassicality even without direct knowledge of Bell's inequalities for the given problem. An extensive set of numerical results is presented and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-D-18A-04: Quantifying the Ability of Tumor Tracking to Spare Normal Tissue

Purpose: Tumor tracking allows for smaller tissue volumes to be treated, potentially reducing normal tissue damage. However, tumor tracking is a more complex treatment and has little benefit in some scenarios. Here we quantify the benefit of tumor tracking for a range of patients by estimating the dose of radiation to organs at risk and the normal tissue complication probability (NTCP) for both standard and tracking treatment plans. This comparison is performed using both patient 4DCT data and extended Cardiac-Torso (XCAT) digital phantoms. Methods: We use 4DCT data for 10 patients. Additionally, we generate digital phantoms with motion derived from measured patient long tumor trajectories to compare standard and tracking treatment plans. The standard treatment is based on the average intensity projection (AIP) of 4DCT images taken over a breath cycle. The tracking treatment is based on doses calculated on images representing the anatomy at each time point. It is assumed that there are no errors in tracking the target. The NTCP values are calculated based on RTOG guidelines. Results: The mean reduction in the mean dose delivered was 5.5% to the lungs (from 7.3 Gy to 6.9 Gy) and 4.0% to the heart (from 12.5 Gy to 12.0 Gy). The mean reduction in the max dose delivered was 13% to the spinal cord (from 27.6 Gy to 24.0 Gy), 2.5% to the carina (from 31.7 Gy to 30.9 Gy), and 15% to the esophagus (from 69.6 Gy to 58.9 Gy). The mean reduction in the probability of 2nd degree radiation pneumonitis (RP) was 8.7% (3.1% to 2.8%) and the mean reduction in the effective volume was 6.8% (10.8% to 10.2%). Conclusions: Tumor tracking has the potential to reduce irradiation of organs at risk, and consequentially reduce the normal tissue complication probability. The benefits vary based on the clinical scenario. This study is supported by Varian Medical Systems, Inc.

60 APPLIED LIFE SCIENCES↗

Smoothing-based compressed state Kalman filter for joint state-parameter estimation: Applications in reservoir characterization and CO 2 storage monitoring

The operation of most engineered hydrogeological systems relies on simulating physical processes using numerical models with uncertain parameters and initial conditions. Predictions by such uncertain models can be greatly improved by Kalman-filter techniques that sequentially assimilate monitoring data. Each assimilation constitutes a nonlinear optimization, which is solved by linearizing an objective function about the model prediction and applying a linear correction to this prediction. However, if model parameters and initial conditions are uncertain, the optimization problem becomes strongly nonlinear and a linear correction may yield unphysical results. In this paper, we investigate the utility of one-step ahead smoothing, a variant of the traditional filtering process, to eliminate nonphysical results and reduce estimation artifacts caused by nonlinearities. Here, we present the smoothing-based compressed state Kalman filter (sCSKF), an algorithm that combines one step ahead smoothing, in which current observations are used to correct the state and parameters one step back in time, with a nonensemble covariance compression scheme, that reduces the computational cost by efficiently exploring the high-dimensional state and parameter space. Numerical experiments show that when model parameters are uncertain and the states exhibit hyperbolic behavior with sharp fronts, as in CO 2 storage applications, one-step ahead smoothing reduces overshooting errors and, by design, gives physically consistent state and parameter estimates. We compared sCSKF with commonly used data assimilation methods and showed that for the same computational cost, combining one step ahead smoothing and nonensemble compression is advantageous for real-time characterization and monitoring of large-scale hydrogeological systems with sharp moving fronts.

42 ENGINEERING↗

Shape-constrained Input Estimation for Efficient Multi-shaker Vibration Testing

Multi-shaker vibration testing is gaining interest from structural dynamics test engineers as it can provide a much more accurate match to complicated field vibration responses than traditional single-axis shaker tests. However, the force capabilities of the small modal shakers typically used in multi-shaker vibration tests has limited the achievable response levels. To date, most multi-shaker vibration tests have been performed using a variety of standard, commercially-available control systems. While these control systems are adequate for a wide range of multiple-input/multiple-output tests, their control algorithms have not been tailored for the specific problem of multi-shaker vibration tests: efficiently coordinating the various shakers to work together to achieve a desired response. Here, a new input estimation algorithm is developed and demonstrated using simulations and actual test data. This algorithm, dubbed shape-constrained input estimation, is shown to effectively coordinate multiple shakers using a set of constraint vectors based on the deflection shapes of the test structure. This is accomplished by using the singular vector shapes of the system frequency response matrix, which allows the constraint vectors to automatically change as a function of frequency. Simulation and test results indicate a significant reduction in the input forces required to achieve a desired response. Finally, the results indicate that shape-constrained input estimation is an effective method to achieve higher response levels from limited shaker forces which will enable higher level multi-shaker vibration tests to be performed.

42 ENGINEERING↗

Long-Term Stability of Mullite and Magnesia-encased Ag|Ag + Reference Electrodes in Molten MgCl 2 -KCl-NaCl

In this study, the stability of Ag|Ag + molten chloride reference electrodes was studied using mullite and magnesia tubes as reference electrode membrane materials in molten MgCl 2 -KCl-NaCl for continuous immersion up to 31 d. Two electrochemical methods were used to characterize the long-term performance of the reference electrodes at 500 °C in an inert atmosphere using a Mg rod as the working electrode: open circuit potential (OCP) and onset of Mg(II) reduction as measured by cyclic voltammetry (CV). There was only a 3% difference between the average OCP measured versus the mullite and MgO reference electrodes. Potential drift was higher for mullite (−1.34 mV d −1 ) than MgO (0.22 mV d −1 ). But both drift rates were very low compared to the OCP data standard deviation, indicating that no significant drift was measured for us to 31 d.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrolytic Oxide Reduction of Plutonium Oxide Surrogates

Our research team has investigated electrolytic oxide reduction (EOR) as an improved metal production process versus the currently employed multiple cycle direct oxide reduction (MCDOR) process for the conversion of plutonium oxide to plutonium metal. Inherent advantages in safety, waste generation, efficiency, and operational ease make EOR an attractive alternative to traditional metal production practices. Phase I of the project consisted of the construction of a prototype electrochemical cell, and proof of concept experiments towards the reduction of SnO 2 and CeO 2 compounds. Phase II of the project was focused on the optimization of the cerium system in preparation for future plutonium EOR experiments. We observed the electrolytic reduction of cerium oxide resulting in mixed degrees of success, and discovered this was a result of parasitic side reactions and partial reduction. We employed cyclic voltammetry (CV) to identify the products of these side reactions and characterize partially reduced species. We also observed that, when metal was successfully produced by EOR, a large amount of passed charge was required. We concluded that this observation was due to several inefficiencies of the process relating to the reduction mechanism (e.g. inefficient use of cathodically produced calcium). We used our CV results to guide our optimization of the EOR of CeO 2 by refining our electrochemical method, cell geometry, and materials of construction. Finally, we developed a next generation cell, worked to establish a new molten salt electrochemical capability in the Plutonium Facility, and completed a strategy for plutonium experiments. Our electrochemical method to produce plutonium metal clearly supports the core mission of the laboratory. Furthermore, this project has allowed for the development of capabilities that will provide valuable data to programs interested in characterization and detection, as well as science of signatures. Additionally, establishing this capability in the plutonium facility will facilitate future safeguard studies that can assist with safeguard development in molten salt reprocessing flowsheets, and molten salt reactor designs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward the Analytic Bootstrap of Energy Correlators

In this paper, we present a framework for the analytic bootstrap of three-point energy correlators, a crucial observable in N = 4 N=4 super Yang-Mills theory and quantum chromodynamics (QCD). Our approach combines spherical contour techniques, general physical constraints such as pole cancellations, and power correction data in the singular limits to determine its analytic expression. In contrast to previous bootstrap studies restricted to scattering amplitudes for supersymmetric theories, our framework makes use of the properties of Feynman integrals, marking a significant step toward bootstrapping realistic QCD observables. Using this method, we derive analytic expressions for leading-order three-point energy correlators with equal and unequal energy weights, where the latter are crucial ingredients for projected N N-point energy correlators. We also apply the recently developed technique of analytic regression with lattice reduction as a way to bypass needing explicit expressions for the singular limits. Bridging theoretical advances in scattering amplitudes with the renewed interest in weighted cross-sections, our work opens the door to precision tests of QCD dynamics through analytic event-shape predictions.

Gong, Jianyu [State Key Laboratory]↗

Control algorithms for dynamic attenuators

Purpose: The authors describe algorithms to control dynamic attenuators in CT and compare their performance using simulated scans. Dynamic attenuators are prepatient beam shaping filters that modulate the distribution of x-ray fluence incident on the patient on a view-by-view basis. These attenuators can reduce dose while improving key image quality metrics such as peak or mean variance. In each view, the attenuator presents several degrees of freedom which may be individually adjusted. The total number of degrees of freedom across all views is very large, making many optimization techniques impractical. The authors develop a theory for optimally controlling these attenuators. Special attention is paid to a theoretically perfect attenuator which controls the fluence for each ray individually, but the authors also investigate and compare three other, practical attenuator designs which have been previously proposed: the piecewise-linear attenuator, the translating attenuator, and the double wedge attenuator. Methods: The authors pose and solve the optimization problems of minimizing the mean and peak variance subject to a fixed dose limit. For a perfect attenuator and mean variance minimization, this problem can be solved in simple, closed form. For other attenuator designs, the problem can be decomposed into separate problems for each view to greatly reduce the computational complexity. Peak variance minimization can be approximately solved using iterated, weighted mean variance (WMV) minimization. Also, the authors develop heuristics for the perfect and piecewise-linear attenuators which do not requirea priori knowledge of the patient anatomy. The authors compare these control algorithms on different types of dynamic attenuators using simulated raw data from forward projected DICOM files of a thorax and an abdomen. Results: The translating and double wedge attenuators reduce dose by an average of 30% relative to current techniques (bowtie filter with tube current modulation) without increasing peak variance. The 15-element piecewise-linear dynamic attenuator reduces dose by an average of 42%, and the perfect attenuator reduces dose by an average of 50%. Improvements in peak variance are several times larger than improvements in mean variance. Heuristic control eliminates the need for a prescan. For the piecewise-linear attenuator, the cost of heuristic control is an increase in dose of 9%. The proposed iterated WMV minimization produces results that are within a few percent of the true solution. Conclusions: Dynamic attenuators show potential for significant dose reduction. A wide class of dynamic attenuators can be accurately controlled using the described methods.

61 RADIATION PROTECTION AND DOSIMETRY↗

Kinetics of Reduction of Low-Grade Nickel Laterite Ore Using Carbon Monoxide

Reduction of a low-grade nickel laterite ore with carbon monoxide to produce Fe-Ni alloy was investigated using a thermo-gravimetric analysis (TGA) method. Non-isothermal reduction tests with a fixed heating rate of 10 °C/min from room temperature to 1200 °C were carried out to determine the different reduction stages and reaction products in each state. Combining measured mass losses with theoretically calculated values together with X-ray diffraction analysis, the products of different reduction stages were identified and a reaction path was established. Isothermal reduction tests with temperatures ranging from 500 °C to 1100 °C were performed to evaluate the temperature dependence of the reduction kinetics. Various kinetic models were fitted to the experimental data to further determine the rate-controlling step in the isothermal tests. Then, two groups of TG experiments were carried out to study the effect of CO flow rate and sample mass on the rate of reaction. The results indicated that the reduction rate increases with the increase of the reduction temperature from 500 °C to 1100 °C. More alloy products are formed and the apparent activation energies increase from 8.6 to 14.7 kJ/mol with the increase of the reduction temperature from 700 °C to 1100 °C. Accordingly, it was proposed that diffusion of CO in the gas bulk and through the pores of the laterite ore sample bed are the rate limiting steps.

36 MATERIALS SCIENCE↗

An efficient MILP framework for integrating nonlinear process dynamics and control in optimal production scheduling calculations

The emphasis currently placed on enterprise-wide decision making and optimization has led to an increased need for methods of integrating nonlinear process dynamics and control information in scheduling calculations. The inevitable high dimensionality and nonlinearity of first-principles dynamic process models makes incorporating them in scheduling calculations challenging. In this work, we describe a general framework for deriving data-driven surrogate models of the closed-loop process dynamics. Focusing on Hammerstein–Wiener and finite step response (FSR) model forms, we show that these models can be (exactly) linearized and embedded in production scheduling calculations. The resulting scheduling problems are mixed-integer linear programs with a special structure, which we exploit in a novel and efficient solution strategy. A polymerization reactor case study is utilized to demonstrate the merits of this method. Finally, our framework compares favorably to existing approaches that embed dynamics in scheduling calculations, showing considerable reductions in computational effort.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predictors of Androgen Deprivation Therapy Efficacy Combined With Prostatic Irradiation: The Central Role of Tumor Stage and Radiation Dose

Purpose: To evaluate the response of clinically localized prostate cancer to various durations of planned androgen deprivation therapy (ADT) and to investigate subgroups predicting response. Methods and Materials: Data of 3,666 prostate cancer patients treated with either combined ADT and external beam radiotherapy (EBRT) or EBRT alone at four institutions were examined. ADT consisted of neoadjuvant, concurrent, or adjuvant ADT or combinations of these regimens. The primary endpoint was time to biochemical failure (nadir plus 2 ng/ml), assessed from the end of therapy. Factors predictive for the need for ADT were examined with interaction analyses. Results: The impact of increasing ADT duration was nonlinear with, on average, 6 months of adjuvant ADT resulting in a reduction of the risk of biochemical failure by 38% (95% confidence interval [CI], 29%-46%), while 12, 24, and 36 months of ADT resulted in a 58% (95% CI, 47%-67%), 66% (95% CI, 55%-75%), and 66% (95% CI, 51%-77%) relative failure reduction, respectively. Patients with higher T stage cancers and those treated with lower radiation doses had a significantly greater benefit for increasing ADT duration (interaction, p = 0.016 and p = 0.007, respectively). Pretreatment prostate-specific antigen values, Gleason score, age, and risk group did not modify the response to ADT. Conclusions: The known ADT efficacy derived from randomized studies can be generalized to patients with different features, and individual predictions of potential benefit from ADT use and duration may be calculated to aid patient and physician decision making. Tumor stage and radiation dose variations were related to significantly different ADT duration effects. The validity of these predictive factors requires prospective evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗