Search NASA⌕ Search

SEARCH · Search NASA

Results for “Design of Experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Intelligent Sampling for Surrogate Modeling, Hyperparameter Optimization, and Data Analysis

Sampling techniques are used in many fields, including design of experiments, image processing, and graphics. The techniques in each field are designed to meet the constraints specific to that field such as uniform coverage of the range of each dimension or random samples that are at least a certain distance apart from each other. When an application imposes new constraints, for example, by requiring samples in a non-rectangular domain or the addition of new samples to an existing set, a common solution is to modify the algorithm currently in use, often with less than satisfactory results. As an alternative, we propose the concept of intelligent sampling, where we devise algorithms specifically tailored to meet our sampling needs, either by creating new algorithms or by modifying suitable algorithms from other fields. Surprisingly, both qualitative and quantitative comparisons indicate that some relatively simple algorithms can be easily modified to meet the many sampling requirements of surrogate modeling, hyperparameter optimization, and data analysis; these algorithms outperform their more sophisticated counterparts currently in use, resulting in better use of time and computer resources.

97 MATHEMATICS AND COMPUTING↗

MITR DDE End Fitting Structural Rigidity Analysis

As a part of the design of the MITR Design Demonstration Element (DDE), a new design for the end fittings must be considered to meet specific experiment needs, e.g., compatibility with the geometrical restrictions of the DDE testing location (BR2 test reactor located in Mol, Belgium), and to allow for proper inspection of these test elements during the experiments. The design of the MITR DDE end fittings is substantially different from the design of the end fittings of the MITR LEU fuel elements, with the DDE end fittings considerably smaller in overall size and weight. Consequently, the stiffness of the end fittings as well as of the entire fuel element is affected. The end fittings in the MITR LEU fuel element are designed primarily for proper handling and flow distribution. The stiffness of the end fittings also constitutes a fraction of the total stiffness of the entire fuel element. It is debatable to what extent the end fittings provide the structural rigidity necessary for the fuel element to properly respond to potential loadings. It is presumed that the bulk of the overall stiffness of the element is derived from swaging multiple fuel plates into the side plates. However, the contribution of stiffness from various components of the MITR LEU fuel element and MITR DDE has not been determined so far. The primary objective of the work presented in this report was to assess the extent to which the stiffness of the end fitting in the MITR DDE contributes to the stiffness of the entire fuel element, and how it compares to the equivalent stiffness of the end fitting in the MITR LEU fuel element. Several simplified load cases were analyzed for that purpose using the geometries of the MITR LEU fuel element, MITR DDE, as well as that of the MITR DDE without the top end fitting.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Electric Submersible Pump Design Tool for Geothermal Applications

Electrical Submersible Pumps (ESPs) present higher efficiency, larger production rate, and can be operated in deeper wells than the other geothermal artificial lifting systems. Enhanced Geothermal Systems (EGS) applications recommend lifting 300 C geothermal water at 80kg/s flow rate in a maximum 10-5/8-inch diameter wellbore to improve the cost-effectiveness. In this paper, an advanced ESP design tool comprising a 1D theoretical model and a 3D CFD analysis has been developed to design ESPs for geothermal applications. Design of Experiments was also performed to optimize the geometry and performance. The designed mixed-flow type centrifugal impeller and diffuser exhibit high efficiency and head rise under simulated EGS conditions. The design tool has been validated by comparing the prediction to experimental data of an existing ESP product.

15 GEOTHERMAL ENERGY↗

Neutron Noise Analysis of the Neptunium Subcritical Observation (NESO) Experiment

The Neptunium Subcritical Observation (NeSO) experiment was a subcritical integral benchmark experiment. This experiment was designed in 2017-2018 and was performed at the National Criticality Experiments Research Center (NCERC) in 2019. Eight different subcritical configurations were measured with varying Nickel reflector thickness. For all configurations, a 3 He detection system was used to record neutron events. The focus of this work is to share neutron noise results of the measured data.

3-Helium↗

Neutron Noise Analysis of the Neptunium Subcritical Observation (NESO) Experiment

The Neptunium Subcritical Observation (NeSO) experiment was a subcritical integral benchmark experiment. This experiment was designed in 2017-2018 and was performed at the National Criticality Experiments Research Center (NCERC) in 2019. Eight different subcritical configurations were measured with varying Nickel reflector thickness. For all configurations, a 3 He detection system was used to record neutron events. The focus of this work is to share neutron noise results of the measured data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predictive Maturity of Multi-Scale Simulation Models for Fuel Performance

The project proposed to provide a Predictive Maturity Framework with its companion metrics that (1) introduce a formalized, quantitative means to communicate information between interested parties, (2) provide scientifically dependable means to claim completion of Validation and Uncertainty Quantification (VU) activities, and (3) guide the decision makers in the allocation of Nuclear Energy’s resources for code development and physical experiments. The project team proposed to develop this framework based on two complimentary criteria: (1) the extent of experimental evidence available for the calibration of simulation models and (2) the sophistication of the physics incorporated in simulation models. The proposed framework is capable of quantifying the interaction between the required number of physical experiments and degree of physics sophistication. The project team has developed this framework and implemented it with a multi-scale model for simulating creep of a core reactor cladding. The multi-scale model is composed of the viscoplastic self-consistent (VPSC) code at the meso-scale, which represents the visco-plastic behavior and changing properties of a highly anisotropic material and a Finite Element (FE) code at the macro-scale to represent the elastic behavior and apply the loading. The framework developed takes advantage of the transparency provided by partitioned analysis, where independent constituent codes are coupled in an iterative manner. This transparency allows model developers to better understand and remedy the source of biases and uncertainties, whether they stem from the constituents or the coupling interface by exploiting separate-effect experiments conducted within the constituent domain and integral-effect experiments conducted within the full-system domain. The project team has implemented this procedure with the multi- scale VPSC-FE model and demonstrated its ability to improve the predictive capability of the model. Within this framework, the project team has focused on optimizing resource allocation for improving numerical models through further code development and experimentation. Related to further code development, we have developed a code prioritization index (CPI) for coupled numerical models. CPI is implemented to effectively improve the predictive capability of the coupled model by increasing the sophistication of constituent codes. In relation to designing new experiments, we investigated the information gained by the addition of each new experiment used for calibration and bias correction of a simulation model. Additionally, the variability of ‘information gain’ through the design domain has been investigated in order to identify the experiment settings where maximum information gain occurs and thus guide the experimenters in the selection of the experiment settings. This idea was extended to evaluate the information gain from each experiment can be improved by intelligently selecting the experiments, leading to the development of the Batch Sequential Design (BSD) technique. Additionally, we evaluated the importance of sufficiently exploring the domain of applicability in experiment-based validation of high-consequence modeling and simulation by developing a new metric to quantify coverage. This metric has also been incorporated into the design of new experiments. Finally, we have proposed a data-aware calibration approach for the calibration of numerical models. This new method considers the complexity of a numerical model (the number of parameters to be calibrated, parameter uncertainty, and form of the model) and seeks to identify the number of experiments necessary to calibrate the model based on the level of sophistication of the physics. The final component in the project team’s work to improve model calibration and validation methods is the incorporation of robustness to non-probabilistic uncertainty in the input parameters. This is an improvement to model validation and uncertainty quantification stemming beyond the originally proposed scope of the project. We have introduced a new metric for incorporating the concept of robustness into experiment-based validation of numerical models. This project has accounted for the graduation of two Ph.D. students (Kendra Van Buren and Josh Hegenderfer) and two M.S. students (Matthew Egeberg and Parker Shields). One of the doctoral students is now working in the nuclear engineering field and the other one is a post-doctoral fellow at the Los Alamos National Laboratory. Additionally, two more Ph.D. students (Garrison Stevens and Tunc Kulaksiz) who are working towards graduation have been supported by this project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Virtual Model Validation of Complex Multiscale Systems: Applications to Nonlinear Elastostatics

We propose a virtual statistical validation process as an aid to the design of experiments for the validation of phenomenological models of the behavior of material bodies, with focus on those cases in which knowledge of the fabrication process used to manufacture the body can provide information on the micro-molecular-scale properties underlying macroscale behavior. One example is given by models of elastomeric solids fabricated using polymerization processes. We describe a framework for model validation that involves Bayesian updates of parameters in statistical calibration and validation phases. The process enables the quanti cation of uncertainty in quantities of interest (QoIs) and the determination of model consistency using tools of statistical information theory. We assert that microscale information drawn from molecular models of the fabrication of the body provides a valuable source of prior information on parameters as well as a means for estimating model bias and designing virtual validation experiments to provide information gain over calibration posteriors.

97 MATHEMATICS AND COMPUTING↗

The Holometer: A Fermilab Experiment

Do we live in a two-dimensional hologram? A group of Fermilab scientists has designed an experiment to find out. It’s called the Holometer, and this video gives you a behind-the-scenes look at the device that could change the way we see the universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

IER305: Molybdenum Sleeve Experiments in the Sandia Critical Experiments Facility [Slides]

This presentation is on the Molybdenum (Mo) sleeve experiments at the Sandia Critical Experiments Facility. The Institut de Radioprotection et de Sûreté Nucléaire (IRSN) performed the preliminary design of the experiment. IRSN performed the final nuclear design of the experiment. Sandia performed the detailed design of the experiment to make it work in the critical assembly and Sandia also oversaw the fabrication and installation of the hardware. The slides include cutaway and overall views and a look into the results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimizing ablator thickness for laser shock experiments

In laser shock experiments, a well-defined, flat-top shock wave at the ablator/sample interface is important for accurately probing material response under uniaxial strain compression. However, the relationship between the ablator thickness and the resulting shock wave characteristics is insufficiently understood, limiting the ability to design optimal experiments. To address this need, we conducted a systematic experimental study using a 100 J laser to shock-compress polyimide ablators to peak stresses ranging from 20.4 to 111.6 GPa. Laser interferometry diagnostics measured the transmitted wave profiles at the ablator/sample interface, consistently showing a single jump followed by a constant peak state before the arrival of release waves. Here, by analyzing shock transit time, flat-top duration, and stress, our results establish a framework for selecting ablator thickness to maximize the flat-top duration, improving the precision and reproducibility of laser shock experiments.

design of experiments↗

Use of Criticality Eigenvalue Simulations for Subcritical Benchmark Evaluations

Subcritical multiplication experiments and simulations are important for a variety of applications including nonproliferation, safeguards, and criticality safety monitoring. Recently, subcritical experiments have been evaluated for inclusion in the International Criticality Safety Benchmark Evaluation Process (ICSBEP). In addition, new subcritical experiments have recently been designed. In these experiments, list-mode data (a list of each absorption in the neutron detector) is recorded and neutron noise analysis is used to determine the leakage multiplication (ML) of each configuration. One downside to the simulation of these types of experiments is that they are computationally expensive. This is because analog Monte Carlo with no variance reduction must be performed in order to maintain the time accuracy required in the measurement analysis. This work demonstrates that criticality eigenvalue simulations can be used to estimate sensitivities and uncertainties for three parameters: singles count rate (R{sub 1}), doubles count rate (R{sub 2}), and leakage multiplication (M{sub L}). This will provide a useful aid both in the design and evaluation of new subcritical measurements. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Unified User-Friendly Instrument Control and Data Acquisition System for the ORNL SANS Instrument Suite

In an effort to upgrade and provide a unified and improved instrument control and data acquisition system for the Oak Ridge National Laboratory (ORNL) small-angle neutron scattering (SANS) instrument suite—biological small-angle neutron scattering instrument (Bio-SANS), the extended q-range small-angle neutron scattering diffractometer (EQ-SANS), the general-purpose small-angle neutron scattering diffractometer (GP-SANS)—beamline scientists and developers teamed up and worked closely together to design and develop a new system. We began with an in-depth analysis of user needs and requirements, covering all perspectives of control and data acquisition based on previous usage data and user feedback. Our design and implementation were guided by the principles from the latest user experience and design research and based on effective practices from our previous projects. In this article, we share details of our design process as well as prominent features of the new instrument control and data acquisition system. The new system provides a sophisticated Q-Range Planner to help scientists and users plan and execute instrument configurations easily and efficiently. The system also provides different user operation interfaces, such as wizard-type tool Panel Scan, a Scripting Tool based on Python Language, and Table Scan, all of which are tailored to different user needs. The new system further captures all the metadata to enable post-experiment data reduction and possibly automatic reduction and provides users with enhanced live displays and additional feedback at the run time. We hope our results will serve as a good example for developing a user-friendly instrument control and data acquisition system at large user facilities.

47 OTHER INSTRUMENTATION↗

Detector Development for the MARE Neutrino Experiment

The MARE experiment is designed to measure the mass of the neutrino with sub-eV sensitivity by measuring the beta decay of {sup 187}Re with cryogenic microcalorimeters. A preliminary analysis shows that, to achieve the necessary statistics, between 10,000 and 50,000 detectors are likely necessary. We have fabricated and characterized Iridium transition edge sensors with high reproducibility and uniformity for such a large scale experiment. We have also started a full scale simulation of the experimental setup for MARE, including thermalization in the absorber, detector response, and optimum filter analysis, to understand the issues related to reaching a sub-eV sensitivity and to optimize the design of the MARE experiment. We present our characterization of the Ir devices, including reproducibility, uniformity, and sensitivity, and we discuss the implementation and capabilities of our full scale simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MERIT High-Power Target Experiment at the CERN PS.

The MERIT experiment was designed as a proof-of-principle test of a target system based on a free mercury jet inside a 15-T solenoid that is capable of sustaining proton beam powers of up to 4 MW. The experiment was run at CERN in the fall of 2007. We describe the results of the tests and their implications. Plans are being discussed for possible future machines which can deliver proton beams with multi-MW beam powers. A prominent application for these powerful beams will be to produce intense secondary beams suitable for investigating important physics issues. Examples include investigations of rare decay processes and neutrino oscillations. The Neutrino Factory and Muon Collider Collaboration [1] has proposed a target system [2, 3] which will be capable of supporting proton beam powers of 4 MW with the purpose of producing and collecting intense muon beams for eventual use in storage rings. The core of this proposed target system consists of a high-Z, free-flowing liquid mercury jet which intercepts the proton beam within the confines of a high-field (15-20 T) solenoid. An important attribute of this system is that the liquid jet target can be replaced for subsequent proton pulses. The experiment described in this paper was designed to provide a proof-of-principle demonstration of this concept. Preparations for this experiment have been previously reported [4].

43 PARTICLE ACCELERATORS↗

Shattered pellet injection experiments at JET in support of the ITER disruption mitigation system design

A series of experiments have been executed at JET to assess the efficacy of the newly installed shattered pellet injection (SPI) system in mitigating the effects of disruptions. Issues, important for the ITER disruption mitigation system, such as thermal load mitigation, avoidance of runaway electron (RE) formation, radiation asymmetries during thermal quench mitigation, electromagnetic load control and RE energy dissipation have been addressed over a large parameter range. The efficiency of the mitigation has been examined for the various SPI injection strategies. Here, the paper summarises the results from these JET SPI experiments and discusses their implications for the ITER disruption mitigation scheme.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design Calculations For NIF Convergent Ablator Experiments

The NIF convergent ablation tuning effort is underway. In the early experiments, we have discovered that the design code simulations over-predict the capsule implosion velocity and shock flash rhor, but under-predict the hohlraum x-ray flux measurements. The apparent inconsistency between the x-ray flux and radiography data implies that there are important unexplained aspects of the hohlraum and/or capsule behavior.

42 ENGINEERING↗

Experimental research on Ku-band magnetically insulated transmission line oscillator

An improved Ku-band magnetically insulated transmission line oscillator is proposed and investigated experimentally. In the particle-in-cell simulation, the Ku-band MILO generates the microwave with a power of 1.62 GW and a frequency of 13 GHz at the input voltage of 474 kV. The device is fabricated based on the simulation results, and an experiment system is designed. In the preliminary experiments, output microwave with frequency of 13.02 GHz, power of 150 MW, and pulse width of 17 ns is generated, under the diode voltage of 450 kV. Analysis on the experiment results shows that plasma produced due to the large current hitting to the outside of the collection tank is the essential cause for the low amplitude of the microwave power and short pulse width.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a mnemonic discrimination task using naturalistic stimuli with applications to aging and preclinical Alzheimer's disease

Most tasks test memory within the same day, however, most forgetting occurs after 24 h. Further, testing memory for simple words or objects does not mimic real-world memory experiences. We designed a memory task showing participants video clips of everyday kinds of experiences, including positive, negative, and neutral stimuli, and tested memory immediately and 24 h later. During the memory test, we included repeated and similar stimuli to tax both target recognition and lure discrimination ability. Participants’ memory was worse after 24 h, especially the ability to discriminate similar stimuli. Emotional videos were better remembered when tested immediately, however, after 24 h we find gist versus detail trade-offs in emotional forgetting. We also applied this paradigm to a sample of cognitively normal older adults that also underwent amyloid and tau PET imaging. We found that older adults performed worse on the task compared to young adults. While both young and older adults showed similar patterns of forgetting of repeated emotional and neutral clips, older adults showed preserved neutral compared to emotional discrimination after 24 h. Further, lure discrimination performance correlated with medial temporal lobe tau in older adults with preclinical Alzheimer’s disease. These results suggest factors such as time between encoding and retrieval, emotion, and similarity influence memory performance and should be considered when examining memory performance for an accurate picture of memory function and dysfunction.

59 BASIC BIOLOGICAL SCIENCES↗