Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Enhancing Distribution Grid Resilience Through Model Predictive Controller Enabled Prioritized Load Restoration Strategy: Preprint

Effective resilience improvement strategies enable the power grid to cope with disruptive extreme events. Most power grid outages are caused by disruptions in distribution grids. Motivated by the urgent need for power system resilience research, this paper proposes a priority-weighted optimal load restoration technique to enhance the resilience of distribution grids against extreme events. The proposed technique is based on smart distribution technology and framed as sequential multi-step decision process (MDP) and mixed integer linear program (MILP). It is formulated as optimal control problem with a model predictive control (MPC) approach. We applied the devised MILP-MPC-based load restoration technique to a simplified single-bus version of the IEEE 13-bus distribution system with integrated distributed energy resources (DERs) such as wind turbine, photovoltaic array, microturbine, and energy storage device. The technique executes a reducing and rolling horizon optimization in each control step in real-time using the forecasted information of the renewables, the fuel status of the microturbine and the state of charge of the energy storage device. We consider an extreme event which triggered outage of the upstream utility grid and caused islanded operation of the distribution grid. We demonstrated the effectiveness of the proposed MPC approach in restoring the distribution grid loads based on their priority during the main grid outage-caused islanded operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enhancing Distribution Grid Resilience Through Model Predictive Controller Enabled Prioritized Load Restoration Strategy

Effective resilience improvement strategies enable the power grid to cope with disruptive extreme events. Most power grid outages are caused by disruptions in distribution grids. Motivated by the urgent need for power system resilience research, this paper proposes a priority-weighted optimal load restoration technique to enhance the resilience of distribution grids against extreme events. The proposed technique is based on smart distribution technology and framed as sequential multi-step decision process (MDP) and mixed integer linear program (MILP). It is formulated as optimal control problem with a model predictive control (MPC) approach. We applied the devised MILP-MPC-based load restoration technique to a simplified single-bus version of the IEEE 13-bus distribution system with integrated distributed energy resources (DERs) such as wind turbine, photovoltaic array, microturbine, and energy storage device. The technique executes a reducing and rolling horizon optimization in each control step in real-time using the forecasted information of the renewables, the fuel status of the microturbine and the state of charge of the energy storage device. We consider an extreme event which triggered outage of the upstream utility grid and caused islanded operation of the distribution grid. We demonstrated the effectiveness of the proposed MPC approach in restoring the distribution grid loads based on their priority during the main grid outage-caused islanded operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Implementing Cybersecurity for Distributed Wind: An Exercise in ICS Security Application

Distributed wind is unique and fast-growing component of the energy production mix, but cybersecurity for distributed wind is not well developed. In this presentation, we will introduce distributed wind as an example of difficult-to-secure critical infrastructure. We will first provide background on distributed wind architectures, applications, and stakeholder roles. We will explain the need and challenges for cybersecurity for distributed wind, pointing to both academic studies and real-world events. The key component of the presentation will discuss recommendations for different aspects of security, such as risk assessments, communications, and access control, that specifically call out considerations that apply uniquely to distributed wind. We will discuss what sets distributed wind apart from other ICS and energy applications, and how to account for these features in a comprehensive security plan. This process is demonstrative of the type of analysis needed to adapt traditional security guidelines and standards to narrow and focused applications.

17 WIND ENERGY↗

Particulate distribution function evolution for ejecta transport

The time evolution of the ejecta distribution function in a gas is discussed in the context of the recent experiments of W. Buttler and M. Zellner for well characterized Sn surfaces. Evolution equations are derived for the particulate distribution function when the dominant gas-particle interaction in is particulate drag. In the approximation of separability of the distribution function in velocity and size, the solution for the time dependent distribution function is a Fredholm integral equation of the first kind whose kernel is expressible in terms of the vacuum time dependent velocity distribution function measured with piezo probes or Asay foils. The solution of this equation in principle gives the size distribution function. We discuss the solution of this equation and the results of the Buttler - Zellner experiments. These suggest that correlations in velocity and size are necessary for a complete description of the transport dala. The solutions presented also represent an analytic test problem for the calculated distribution function in ejecta transport implementations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Voltage regulation in distribution grids: A survey

Environmental and sustainability concerns have caused a recent surge in the penetration of distributed energy resources into the power grid. This may lead to voltage violations in the distribution systems making voltage regulation more relevant than ever. Owing to this and rapid advancements in sensing, communication, and computation technologies, the literature on voltage control techniques is growing at a rapid pace in distribution networks. In particular, there is a paradigm shift from traditional offline centralized approaches to distributed ones leveraging increased and varied types of actuators, real-time sensing, fast and efficient computations, and an overall distributed situational awareness. This paper reviews state-of-the-art voltage control algorithms, summarizes the underlying methods, and classifies their coordination mechanisms into local, centralized, distributed, and decentralized. The underlying solution methodologies are further classified into two categories, open-loop and feedback-based. Two specific example workflows are provided to illustrate these solutions for voltage regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Quality Analysis and Solutions for Distribution-Level PMUs

Synchrophasors provide promising enhancement to the distribution system monitoring. However, different from transmission systems, distribution systems are usually with higher noise, phase unbalance, and distributed energy resources. All of these could impair the data quality of distribution-level phasor measurement units (D-PMUs) and thus deteriorate the performance of D-PMU based applications. Therefore, the data quality of D-PMU should be evaluated to ensure the effectiveness of D-PMU based applications. In this paper, factors in distribution systems that could jeopardize D-PMU data quality are evaluated. The impact of data quality on D-PMU applications is analyzed. Finally, solutions are proposed to improve D-PMU data quality to satisfy these requirements. This work provides effective methods to improve the performance of distribution-level grid monitoring using synchrophasor measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Locating the Source of Events in Power Distribution Systems Using Micro-PMU Data

A novel method is proposed to locate the source of events in power distribution systems by using distribution-level phasor measurement units, a.k.a., micro-PMUs. An event in this paper is defined rather broadly to include any major change in any component across the distribution feeder. The goal is to enhance situational awareness in distribution grid by keeping track of the operation (or misoperation) of various grid equipment, assets, distribution energy resources, loads, etc. The proposed method is built upon the compensation theorem in circuit theory to generate an equivalent circuit to represent the event by using voltage and current synchrophasors that are captured by micro-PMUs. Importantly, this method makes critical use of not only magnitude but also synchronized phase angle measurements, thus, it justifies the need to use micro-PMUs, as opposed to ordinary RMS-based voltage and current sensors. The proposed method can work with data from as a few as only two micro-PMUs. The effectiveness of the developed method is demonstrated through computer simulations on the IEEE 123-bus test system, and also on micro-PMUs measurements from a real-life 12.47 kV test feeder in Riverside, CA. In conclusion, the results verify that the proposed method is accurate and robust in locating the source of different types of events on power distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilience Analytics for Interdependent Power and Water Distribution Systems

The occurrence of large-scale outages in power distribution systems (PDSs) caused, for instance, by extreme weather events has raised concerns on the cascading impact of the power outages on the resilience of other critical infrastructures, including water distribution systems (WDSs), whose healthy operation highly relies on the availability of power from PDSs. Here, this paper proposes an analytics model for quantifying the interdependence between the resilience of power and water distribution systems. The proposed model first performs spatio-temporal outage analysis on the PDS and WDS to determine the PDS power serving capability and the resulting cascading impact on the WDS water serving capability during the occurrence of disruptions. The resilience interdependence is then determined by a proposed set of six metrics calculated using the power and water serving capability profiles, which trace and quantify the cascading impacts of power outages in the operation of WDSs during the degradation and recovery stages. The proposed analytics model is implemented on the IEEE 33-bus power distribution system supplying power for pumping stations of a 15-node test WDS, considering multiple cases of water storage capacity, single and multiple outage scenarios, and availability of distributed generation. The numerical results demonstrate that the proposed metrics track the temporal and spatial interdependence between the resilience of power and water distribution systems, providing a mechanism to identify weak spots, and assess options to enhance the resilience of the critical water infrastructure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Employing Interacting Qubits for Distributed Microgrid Control

To empower flexible and scalable operations, distributed control of multi-inverter microgrids, based on classical communication networks among distributed energy resources, has attracted considerable attention as it can guarantee synchronization and provide suitable remedies to the problem of improper power sharing. Notwithstanding this, resilience of the current schemes on classical communication makes microgrids vulnerable to cyber attacks. Inspired by recent revolutionary breakthroughs in quantum communication, in this paper, we devise a novel synchronization mechanism. We extend the synchronization framework utilized in distributed control algorithms to networks of quantum systems by generating pinning terms and coupling mechanism for the new synchronization rule via exploiting proper quantum jump operators and observables, and show that the quantum system will converge to a time-variant target state. Our devised quantum distributed controller (QDC) gives rise to a novel quantum communication scheme for distributed control of microgrids and enables microgrids to exploit the state-of-the-art quantum communication frameworks as communication infrastructure. Finally, test results on two representative AC and DC networked microgrids validate the efficacy and universality of the quantum distributed control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification: Preprint

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs)at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases - distribution system state estimation (DSSE) and fault identification - are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system monitoring↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Neural network modeling of in situ fluid-filled pore size distributions in subsurface shale reservoirs under data constraints

Subsurface nuclear magnetic resonance (NMR) logs acquired in the wellbore environment are sensitive to fluid-filled pore size distribution, fluid mobility, permeability, and porosity in the near-wellbore reservoir volume. NMR response of a formation layer is processed to extract the T2 distribution, which approximates the fluid-filled pore size distribution. NMR logs are acquired in limited number of wells due to financial and operational challenges, which adversely affects reservoir characterization. We developed here two neural-network-based machine learning techniques, long short-term memory (LSTM) network and variational autoencoder with a convolutional layer (VAEc) network, to process the ‘easy-to-acquire’ formation mineral and fluid saturation logs to generate synthetic NMR T2 distributions in the absence of ‘hard-to-acquire’ NMR T2 distribution log. Both the predictive models are trained and tested on limited wireline log measurements randomly selected from a 300-ft depth interval of the Bakken shale formation. Synthesis performances of LSTM and VAEc models in terms of R 2 are 0.78 and 0.75, respectively. Noise is inevitable in logging data due to the complex wellbore and formation conditions. Notably, both the predictive models robustly synthesize the fluid-filled pore size distributions in the presence of 50% noise in input logs and 30% noise in training T2 data. The performance of the proposed methodology improves with access to larger volume of training data from other formation types. The proposed method is critical to the synthesis of in situ fluid-filled pore size distributions in shale formations under data constraints due to financial and operational challenges.

58 GEOSCIENCES↗

Uniform secondary current distribution at disk electrodes under Tafel kinetics enabled by concentric current-shielding rings

Non-uniform secondary current distribution at rotating disk electrodes (RDE) is a common problem when using resistive electrolyte media or large applied currents. In a recent publication, we have shown that auxiliary electrodes such as the ring of a rotating ring disk electrode (RRDE) can help suppress current non-uniformities at the disk enabling reliable electroanalytical measurements. However, this previous work considered linear kinetics where current distribution non-uniformities were moderate. In the present contribution, we consider current distribution non-uniformities encountered under Tafel kinetics. We show, for the case of 2,5-dihydroxy-1,4-benzoquinone (DHBQ) reduction, that optimally chosen ring conditions serve to provide effective shielding at the disk edge rendering the overall disk current distribution to be uniform. Numerical modeling and scaling analysis (using the Wagner number) are presented to aid a user in determining the optimal ring current density for achieving uniform disk current distribution under Tafel kinetics. This approach is especially useful when studying soluble-soluble redox transitions for which, unlike deposit distribution in electrodeposition, the current distribution non-uniformity is not visually apparent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intersection-distribution-based remapping between arbitrary meshes for staggered multi-material arbitrary Lagrangian-Eulerian hydrodynamics

In this paper, we present a new intersection-distribution-based remapping method between arbitrary polygonal meshes for indirect staggered multi-material arbitrary Lagrangian-Eulerian hydrodynamics. All cell-centered material quantities are conservatively remapped using intersections between the Lagrangian (old, source) mesh and the rezoned (new, target) mesh. The new nodal masses are obtained by conservative distribution of all material masses in each new cell to the cell's corners and then collecting those corner masses at new nodes. This distribution is done using a local constrained optimization approach for each cell in the new mesh. In order to remap nodal momentum we first define cell-centered momentum for each cell in the old mesh, conservatively remap this to the new mesh and then conservatively distribute the new zonal momentum to each cell's bounding nodes, again using local constrained optimization. Our method also conserves total energy by applying a new nodal kinetic energy correction that relies on a process similar to that used for remapping nodal mass and momentum. Cell-centered kinetic energy is computed, conservatively remapped and then distributed to nodes. The discrepancy between this conservatively remapped and actual nodal kinetic energy is then conservatively distributed to the internal energies of the materials in the cells surrounding each node. Unlike conventional cell-based corrections of this type, this new nodal kinetic energy correction has not been observed to drive material internal energy negative in any of our testing. Unlike flux based remapping, our new intersection-distribution method can be applied to remapping between source and target meshes that are arbitrarily different, which provides superior flexibility in the rezoning strategy. Our method is accurate, essentially conservative and essentially bounds preserving.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Proton Cyclotron Waves and Pickup Ion Ring Distribution Instabilities Upstream of Mars

Proton cyclotron waves (PCWs) upstream of Mars are thought to be associated with the instabilities of pickup ions. The instabilities of pickup ions of ring distributions have larger maximum growth rates compared with beam distributions. However, observations revealed a notably‐reduced occurrence rate of PCWs for pickup ions of ring distributions. Linear instability analysis and a corresponding two‐dimensional particle‐in‐cell (PIC) simulation are performed to investigate the instabilities of pickup ion ring distributions upstream of Mars. Linear instability analysis indicates that a pickup ion ring distribution is unstable to the ion cyclotron, ion Bernstein, and mirror instabilities. The corresponding PIC simulation confirms the linear analysis results and further demonstrates that the pickup ions are scattered toward an isotropic shell distribution by the waves excited. Interestingly, the saturation energy of the waves is much lower than that driven by a corresponding pickup ion beam distribution, and mirror waves eventually dominate the system.

79 ASTRONOMY AND ASTROPHYSICS↗

Disc dichotomy signature in the vertical distribution of [Mg/Fe] and the delayed gas infall scenario

Context. Analysis of the Apache Point Observatory Galactic Evolution Experiment project (APOGEE) data suggests the existence of a clear distinction between two sequences of disc stars in the [α/Fe] versus [Fe/H] abundance ratio space, known as the high- and low-α sequence, respectively. This dichotomy also emerges from an analysis of the vertical distribution of the [α/Fe] abundance ratio. Aims. We aim to test whether the revised two-infall chemical evolution models designed to reproduce the low- and high-α sequences in the [α/Fe] versus [Fe/H] ratios in the solar neighbourhood are also capable of predicting the disc bimodality observed in the vertical distribution of [Mg/Fe] in APOGEE DR16 data. Methods. Along with the chemical composition of the simple stellar populations born at different Galactic times predicted by our reference chemical evolution models in the solar vicinity, we provide their maximum vertical height above the Galactic plane |zmax| computed assuming the relation between the vertical action and stellar age in APOGEE thin-disc stars. Result. The vertical distribution of the [Mg/Fe] abundance ratio predicted by the reference chemical evolution models is in agreement with that observed when combining the APOGEE DR16 data (chemical abundances) with the astroNN catalogue (stellar ages, orbital parameters) for stars younger than 8 Gyr (only low-α sequence stars). Including the high-α disc component, the dichotomy in the vertical [Mg/Fe] abundance distribution is reproduced considering the observational cut in the Galactic height of |z|< 2 kpc. However, our model predicts an overly flat (almost constant) growth of the maximum vertical height |zmax| quantity as a function of [Mg/Fe] for high-α objects in contrast with the median values from APOGEE data. Possible explanations for such a tension are that: (i) the APOGEE sample with |z|< 2 kpc is more likely than ours to be contaminated by halo stars, causing the median values to be kinematically hotter, and (ii) external perturbations – such as minor mergers – that the Milky Way experienced in the past could have heated up the disc, and the heating of the orbits cannot be modeled by only scattering processes. Assuming a disc dissection based on chemistry for APOGEE-DR16 stars (|z|< 2 kpc), the observed |zmax| distributions for high-α and low-α sequences are in good agreement with our model predictions if we consider the errors in the vertical action estimates in the calculation. Moreover, a better agreement between predicted and observed stellar distributions at different Galactic vertical heights is achieved if asteroseismic ages are included as a constraint in the best-fit model calculations. Conclusions. The signature of a delayed gas infall episode, which gives rise to a hiatus in the star formation history of the Galaxy, are imprinted both in the [Mg/Fe] versus [Fe/H] relation and in vertical distribution of [Mg/Fe] abundances in the solar vicinity.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigating the vertical distribution of the disk as a function of radial action

As heating processes can broaden the distributions of radial actions and the vertical distributions of the Galactic disks, we investigate the vertical distribution of the Galactic disks as a function of radial action based on Apache Point Observatory Galactic Evolution Experiment (APOGEE) and Gaia data in order to deepen our understanding of the formation and heating history of the Galactic disks. The vertical distributions of the thin and thick Galactic disks defined in the chemical plane were fitted with a simple exponential function with a free parameter of scale height in different radial action ranges. Therefore, we were able to analyze the scale height as a function of radial action for different disk populations. We find that the distributions of radial action for both the thin and thick disks can be approximately described by pseudo-isothermal distributions, which give a statistical measurement for the temperature of the disk as indicated by the mean radial action of the star sample. Estimations of the scale heights in different radial action ranges for these pseudo-isothermal distributions of the disks seem to show fixed relationships between radial action J R and scale height h. We describe these relationships with a two-parameter function of h = √(J R /a)+b, where a and b are free parameters. When testing with a three-parameter function of h = α √(J R /a)+b, we find that this two-parameter function describes the thin disk well, but we note the function should be used with care for the thick disk. When comparing the best-fit relationships between the inner and outer disk for both of the thin and thick disks, we find that the relationships are nearly the same for the thin disks but are different for the thick disks. The inner thick disk shows a nearly flattened relationship, while the outer thick disk presents a gradually increasing relationship. This work highlights an alternative way to unveil the heating history of the disks by investigating the relationship between scale height and radial action, as these relationships encode the formation and heating history of the Galactic disks.

79 ASTRONOMY AND ASTROPHYSICS↗