Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Helical Tomotherapy for Whole-Brain Irradiation With Integrated Boost to Multiple Brain Metastases: Evaluation of Dose Distribution Characteristics and Comparison With Alternative Techniques

Purpose: To quantitatively evaluate dose distribution characteristics achieved with helical tomotherapy (HT) for whole-brain irradiation (WBRT) with integrated boost (IB) to multiple brain metastases in comparison with alternative techniques. Methods and Materials: Dose distributions for 23 patients with 81 metastases treated with WBRT (30 Gy/10 fractions) and IB (50 Gy) were analyzed. The median number of metastases per patient (N{sub mets}) was 3 (range, 2-8). Mean values of the composite planning target volume of all metastases per patient (PTV{sub mets}) and of the individual metastasis planning target volume (PTV{sub ind} {sub met}) were 8.7 ± 8.9 cm{sup 3} (range, 1.3-35.5 cm{sup 3}) and 2.5 ± 4.5 cm{sup 3} (range, 0.19-24.7 cm{sup 3}), respectively. Dose distributions in PTV{sub mets} and PTV{sub ind} {sub met} were evaluated with respect to dose conformity (conformation number [CN], RTOG conformity index [PITV]), target coverage (TC), and homogeneity (homogeneity index [HI], ratio of maximum dose to prescription dose [MDPD]). The dependence of dose conformity on target size and N{sub mets} was investigated. The dose distribution characteristics were benchmarked against alternative irradiation techniques identified in a systematic literature review. Results: Mean ± standard deviation of dose distribution characteristics derived for PTV{sub mets} amounted to CN = 0.790 ± 0.101, PITV = 1.161 ± 0.154, TC = 0.95 ± 0.01, HI = 0.142 ± 0.022, and MDPD = 1.147 ± 0.029, respectively, demonstrating high dose conformity with acceptable homogeneity. Corresponding numbers for PTV{sub ind} {sub met} were CN = 0.708 ± 0.128, PITV = 1.174 ± 0.237, TC = 0.90 ± 0.10, HI = 0.140 ± 0.027, and MDPD = 1.129 ± 0.030, respectively. The target size had a statistically significant influence on dose conformity to PTV{sub mets} (CN = 0.737 for PTV{sub mets} ≤4.32 cm{sup 3} vs CN = 0.848 for PTV{sub mets} >4.32 cm{sup 3}, P=.006), in contrast to N{sub mets}. The achieved dose conformity to PTV{sub mets}, assessed by both CN and PITV, was in all investigated volume strata well within the best quartile of the values reported for alternative irradiation techniques. Conclusions: HT is a well-suited technique to deliver WBRT with IB to multiple brain metastases, yielding high-quality dose distributions. A multi-institutional prospective randomized phase 2 clinical trial to exploit efficacy and safety of the treatment concept is currently under way.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatiotemporal Stability of Cu-ATSM and FLT Positron Emission Tomography Distributions During Radiation Therapy

Purpose: In dose painting, in which functional imaging is used to define biological targets for radiation therapy dose escalation, changes in spatial distributions of biological properties during treatment can compromise the quality of therapy. The goal of this study was to assess the spatiotemporal stability of 2 potential dose painting targets—hypoxia and proliferation—in canine tumors during radiation therapy. Methods and Materials: Twenty-two canine patients with sinonasal tumors (14 carcinoma and 8 sarcoma) were imaged before hypofractionated radiation therapy with copper(II)-diacetyl-bis(N4-methylthiosemicarbazone) (Cu-ATSM) positron emission tomography/computed tomography (PET/CT) for hypoxia and 3′-deoxy-3′-{sup 18}F-fluorothymidine (FLT) PET/CT for proliferation. The FLT scans were repeated after 2 fractions and the Cu-ATSM scans after 3 fractions. Midtreatment PET/CT images were deformably registered to pretreatment PET/CT images. Voxel-based Spearman correlation coefficients quantified the spatial stability of Cu-ATSM and FLT uptake distributions between pretreatment and midtreatment scans. Paired t tests determined significant differences between the patients' respective Cu-ATSM and FLT correlations coefficients. Standardized uptake value measures were also compared between pretreatment and midtreatment scans by use of paired t tests. Results: Spatial distributions of Cu-ATSM and FLT uptake were stable through midtreatment for both sarcomas and carcinomas: the population mean ± standard deviation in Spearman correlation coefficient was 0.88 ± 0.07 for Cu-ATSM and 0.79 ± 0.13 for FLT. The patients' Cu-ATSM correlation coefficients were significantly higher than their respective FLT correlation coefficients (P=.001). Changes in Cu-ATSM SUV measures from pretreatment to midtreatment were histology dependent: carcinomas experienced significant decreases in Cu-ATSM uptake (P<.05), whereas sarcomas did not (P>.20). Both histologies experienced significant decreases in FLT uptake (P<.05). Conclusions: Spatial distributions of Cu-ATSM were very stable after a few fractions of radiation therapy. FLT spatial distributions were generally stable early in therapy, although they were significantly less stable than Cu-ATSM distributions. Canine tumors had significantly lower proliferative activity at midtreatment than at pretreatment, and they experienced histology-dependent changes in Cu-ATSM uptake.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Verification of Dose Distribution in Carbon Ion Radiation Therapy for Stage I Lung Cancer

Purpose: To evaluate robustness of dose distribution of carbon-ion radiation therapy (C-ion RT) in non-small cell lung cancer (NSCLC) and to identify factors affecting the dose distribution by simulated dose distribution. Methods and Materials: Eighty irradiation fields for delivery of C-ion RT were analyzed in 20 patients with stage I NSCLC. Computed tomography images were obtained twice before treatment initiation. Simulated dose distribution was reconstructed on computed tomography for confirmation under the same settings as actual treatment with respiratory gating and bony structure matching. Dose-volume histogram parameters, such as %D95 (percentage of D95 relative to the prescribed dose), were calculated. Patients with any field for which the %D95 of gross tumor volume (GTV) was below 90% were classified as unacceptable for treatment, and the optimal target margin for such cases was examined. Results: Five patients with a total of 8 fields (10% of total number of fields analyzed) were classified as unacceptable according to %D95 of GTV, although most patients showed no remarkable change in the dose-volume histogram parameters. Receiver operating characteristic curve analysis showed that tumor displacement and change in water-equivalent pathlength were significant predictive factors of unacceptable cases (P<.001 and P=.002, respectively). The main cause of degradation of the dose distribution was tumor displacement in 7 of the 8 unacceptable fields. A 6-mm planning target volume margin ensured a GTV %D95 of >90%, except in 1 extremely unacceptable field. Conclusions: According to this simulation analysis of C-ion RT for stage I NSCLC, a few fields were reported as unacceptable and required resetting of body position and reconfirmation. In addition, tumor displacement and change in water-equivalent pathlength (bone shift and/or chest wall thickness) were identified as factors influencing the robustness of dose distribution. Such uncertainties should be regarded in planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging of the Li spatial distribution within V 2 O 5 cathode in a coin cell by neutron computed tomography

An understanding of Lithium (Li) spatial distribution within the electrodes of a Li-ion cell, during charge and discharge cycles, is essential to optimize the electrode parameters for increased performance under cycling. In this work, it is demonstrated that the spatial distribution of Li within Vanadium Pentoxide (V 2 O 5 ) electrodes of a small coin cell can be imaged by neutron computed tomography. The neutron attenuation data has been used to construct the three-dimensional Li spatial images. Specifically, it is shown that there is sufficient neutron imaging contrast between lithiated and delithiated regions of V 2 O 5 electrode making it possible to map Li distributions even in small electrodes with thicknesses <1 mm. The images reveal that the Li spatial distribution is inhomogeneous and a relatively higher C-rate leads to more non-uniform Li distribution after Li insertion. The non-uniform distribution suggests the limitation of Li diffusion within the electrode during the lithiation process under the relatively high cycling rates.

25 ENERGY STORAGE↗

High elongation achieved by band-like distribution of reinforcements in aluminum matrix composites

Highlights: • The high elongation of composites with high reinforcement content has been achieved by band-like distribution of ABO. • The band-like distribution of ABO could lead to more homogenous strain distribution by scattering the damages. • The cracks played a key role in the strain non-localization process, but have negligible contribution to the tensile strain. • A model of the relationship between the ductility enhancement and the band-like distribution of ABO was established. • The residual stresses induced by band-like distribution of ABO were theoretically calculated and experimentally measured. - Abstract: Ductile aluminum matrix composites reinforced by Al{sub 18}B{sub 4}O{sub 33} whisker (ABO) with band-like distribution (Band-like Aluminum Matrix Composites, BAMCs) were fabricated by powder metallurgy and extrusion followed by annealing. The cracks tend to nucleate in the ABO-rich bands, but the band-like structure induces compressive residual stress then suppresses the crack propagation and improves the strain transferring ability in the BAMCs. The denser and smaller cracks formed in the BAMCs with higher ABO volume fraction during tensile test. These cracks play an important role in the strain non-localization process, but have negligible contribution to the tensile strain.

36 MATERIALS SCIENCE↗

Application of chord length distributions and principal component analysis for quantification and representation of diverse polycrystalline microstructures

Highlights: • Microstructure quantification based on directional chord length distribution and principal component analysis is presented • A boundary-based algorithm of calculations of chord length distributions is introduced • Utility of the quantification framework is shown in three case studies on synthetic, experimental, and simulation datasets • Angularly resolved chord length distribution captures essential details of grain size and shape in diverse microstructures • Low-dimensional representations of directional chord length distributions are obtained using principal component analysis - Abstract: Quantification of mesoscale microstructures of polycrystalline materials is important for a range of practical tasks of materials design and development. The current protocols of quantifying grain size and morphology often rely on microstructure metrics (e.g., mean grain diameter) that overlook important details of the mesostructure. In this work, we present a quantification framework based on directionally resolved chord length distribution and principal component analysis as a means of extracting additional information from 2-D microstructural maps. Towards this end, we first present in detail a method for calculating chord length distribution based on boundary segments available in modern digital datasets (e.g., from microscopy post-processing) and their low-rank representations by principal component analysis. The utility of the proposed framework for capturing grain size, morphology, and their anisotropy for efficient visualization, representation, and specification of polycrystalline microstructures is then demonstrated in case studies on datasets from synthetic generation, experiments (on Ni-base superalloys), and simulations (on steel during recrystallization).

36 MATERIALS SCIENCE↗

Evaluation of Patient Residual Deviation and Its Impact on Dose Distribution for Proton Radiotherapy

The residual deviations after final patient repositioning based on bony anatomy and the impact of such deviations on the proton dose distributions was investigated. Digitally reconstructed radiographs (DRRs) and kilovoltage (kV) 'portal verification' images from 10 patients treated with passively scattered proton radiotherapy was used to estimate the residual deviation. These changes were then applied to the location of isocenter points that, in effect, moved the isocenter relative to the apertures and compensators. A composite verification plan was obtained and compared with the original clinical treatment plan to evaluate any changes in dose distributions. The residual deviations were fitted to a Gaussian distribution with {mu} = -0.9 {+-} 0.1 mm and {sigma} = 2.55 {+-} 0.07 mm. The dose distribution showed under- and overcovered dose spots with complex dose distributions both in the target volumes and in the organs at risk. In some cases, this amounts to 63.5% above the intended clinical plan. Although patient positioning is carefully verified before treatment delivery and setup uncertainties are accounted for by using compensator smearing and aperture margins, a residual shift in a patient's position can considerably affect the dose distribution.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of 3D dose distributions for HDR {sup 192}Ir brachytherapy sources with normoxic polymer gel dosimetry and treatment planning system

Radiation fluence changes caused by the dosimeter itself and poor spatial resolution may lead to lack of 3-dimensional (3D) information depending on the features of the dosimeter and quality assurance of dose distributions for high–dose rate (HDR) iridium-192 ({sup 192}Ir) brachytherapy sources is challenging and experimental dosimetry methods used for brachytherapy sources are limited. In this study, we investigated 3D dose distributions of {sup 192}Ir brachytherapy sources for irradiation with single and multiple dwell positions using a normoxic gel dosimeter and compared them with treatment planning system (TPS) calculations. For dose calibration purposes, 100-mL gel-containing vials were irradiated at predefined doses and then scanned in an magnetic resonance (MR) imaging unit. Gel phantoms prepared in 2 spherical glasses were irradiated with {sup 192}Ir for the calculated dwell positions, and MR scans of the phantoms were obtained. The images were analyzed with MATLAB software. Dose distributions and profiles derived with 1-mm resolution were compared with TPS calculations. Linearity was observed between the delivered dose and the reciprocal of the T2 relaxation time constant of the gel. The x-, y-, and z-axes were defined as the sagittal, coronal, and axial planes, respectively, the sagittal and axial planes were defined parallel to the long axis of the source while the coronal plane was defined horizontally to the long axis of the source. The differences between measured and calculated profile widths of 3-cm source length and point source for 70%, 50%, and 30% isodose lines were evaluated at 3 dose levels using 18 profiles of comparison. The calculations for 3-cm source length revealed a difference of > 3 mm in 1 coordinate at 50% profile width on the sagittal plane and 3 coordinates at 70% profile width and 2 coordinates at 50% and 30% profile widths on the axial plane. Calculations on the coronal plane for 3-cm source length showed > 3-mm difference in 1 coordinate at 50% and 70% and 2 coordinates at 30% profile widths. The point source measurements and calculations for 50% profile widths revealed a difference > 3 mm in 1 coordinate on the sagittal plane and 2 coordinates on the axial plane. The doses of 3 coordinates on the sagittal plane and 4 coordinates on the axial plane could not be evaluated in 30% profile width because of low doses. There was good agreement between the gel dosimetry and TPS results. Gel dosimetry provides dose distributions in all 3 planes at the same time, which enables us to define the dose distributions in any plane with high resolution. It can be used to obtain 3D dose distributions for HDR {sup 192}Ir brachytherapy sources and 3D dose verification of TPS.

61 RADIATION PROTECTION AND DOSIMETRY↗

Simulating self-powered neutron detector responses to infer burnup-induced power distribution perturbations in next-generation light water reactors

Understanding how 3D power distribution will be monitored throughout reactor core volumetric space in next-generation nuclear power reactors is crucial to the design, deployment, and licensing of these reactors. Although numerous techniques exist for 3D power distribution monitoring based on the response of both in situ and ex situ sensors currently implemented or proposed for use in the US reactor fleet, crucial details about these techniques are often unclear. The publicly available documentation does not include information such as how well these techniques are characterized and optimized in their implementations and the levels of uncertainty in the inferred 3D power distribution. The work described herein investigated a recently developed 3D power distribution inferencing method as applied to two next-generation reactor simulations: (1) the NuScale small modular reactor design and (2) the Westinghouse AP1000 design, both of which contain in-core strings of vanadium self-powered neutron detectors (SPNDs). This investigation considered a range of SPND string sensor densities, as well as a range of 3D power distribution axial segment sizes. In this work, SPND response simulation is informed by neutron flux calculations in representative homogenized cores. For the different sensor densities and power distribution axial segment sizes in these simulations, the average solution error, solver iterations, and run time were tracked to parameterize the sensor-core configuration.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterizing local high-frequency solar variability and its impact to distribution studies

Accurately representing the local solar variability at timescales relevant to distribution grid operations (30-seconds and shorter) is essential to modeling the impact of solar photovoltaics (PV) on distribution feeders. Due to a lack of available high-frequency solar data, some distribution grid studies have used synthetically-created PV variability or measured PV variability from a different location than their study location. In this work, we show the importance of using accurate solar PV variability inputs in distribution studies. Using high-frequency solar irradiance data from 10 locations in the United States, we compare the ramp rate distributions at the different locations, use a quantitative metric to describe the solar variability, and run distribution simulations using representative 1-week samples from each location to determine the impact of solar variability on the number of tap change operations. Results indicate up to a 300% difference in the number of tap change operations when using PV variability profiles from the different locations.

14 SOLAR ENERGY↗

Recombinant human tripeptidyl peptidase-1 infusion to the monkey CNS: Safety, pharmacokinetics, and distribution

CLN2 disease is caused by deficiency in tripeptidyl peptidase-1 (TPP1), leading to neurodegeneration and death. The safety, pharmacokinetics (PK), and CNS distribution of recombinant human TPP1 (rhTPP1) were characterized following a single intracerebroventricular (ICV) or intrathecal-lumbar (IT-L) infusion to cynomolgus monkeys. Animals received 0, 5, 14, or 20 mg rhTPP1, ICV, or 14 mg IT-L, in artificial cerebrospinal fluid (aCSF) vehicle. Plasma and CSF were collected for PK analysis. Necropsies occurred at 3, 7, and 14 days post-infusion. CNS tissues were sampled for rhTPP1 distribution. TPP1 infusion was well tolerated and without effect on clinical observations or ECG. A mild increase in CSF white blood cells (WBCs) was detected transiently after ICV infusion. Isolated histological changes related to catheter placement and infusion were observed in ICV treated animals, including vehicle controls. The CSF and plasma exposure profiles were equivalent between animals that received an ICV or IT-L infusion. TPP1 levels peaked at the end of infusion, at which point the enzyme was present in plasma at 0.3% to 0.5% of CSF levels. TPP1 was detected in brain tissues with half-lives of 3–14 days. CNS distribution between ICV and IT-L administration was similar, although ICV resulted in distribution to deep brain structures including the thalamus, midbrain, and striatum. Direct CNS infusion of rhTPP1 was well tolerated with no drug related safety findings. The favorable nonclinical profile of ICV rhTPP1 supports the treatment of CLN2 by direct administration to the CNS. - Highlights: • TPP1 enzyme replacement therapy to the CNS is in development for CLN2 disease. • Toxicology, pharmacokinetics, and CNS distribution were assessed in monkeys. • TPP1 infusion directly to the brain did not result in any safety concerns. • A positive pharmacokinetic and distribution profile resulted from TPP1 infusion. • This study demonstrates the feasibility of ICV administered rhTPP1 to treat CLN2.

60 APPLIED LIFE SCIENCES↗

Investigating Characteristic Droplet Size Distributions in Large Eddy Simulations of Stratocumulus Clouds

Cloud processes relevant to radiative and precipitation properties depend on the shape of the cloud droplet size distribution. Recent holographic observations revealed that cloud droplet populations do not have the same size distribution shapes throughout but form regions of characteristic distributions with similar microphysical properties. We investigate the existence and properties of these characteristic distributions within Large‐Eddy Simulations of stratocumulus clouds using Lagrangian and bin microphysics schemes. Distribution types are identified, revealing localized characteristic distributions that vary on the scale of the largest convective cell for simulations with bin microphysics. The results from the Lagrangian microphysics scheme hint at similar behavior. Compared to observations, the simulated clouds are much more uniform. Analysis of the LES results suggests a connection to the local entrainment rate, so the poorly resolved entrainment interface in LES may be a cause of the uniformity. The uniformity of the large‐scale forcing could also be a factor.

cloud droplet size distributions↗

Measurements of Fast Ion Distribution in ICRF Heated Plasmas

Alcator C-Mod uses ICRF for the bulk auxiliary heating and relies primarily on hydrogen minority heating scenarios. Measuring the resulting hydrogen ion distribution provides an opportunity to validate upgraded ICRF simulation capability that includes non-Maxwellian ions. The Compact Neutral Particle Analyzer (CNPA) is a diagnostic employed on Alcator C-Mod to measure this fast ion distribution function. The diagnostic can measure the energy distribution of the fast ion tail, serving as a benchmark for simulation results and allowing for an assessment of the simulation algorithm and physics kernel. In this poster, we will present results from the detector in the most recent campaigns. We will discuss the calculation of the fast ion distribution from the measured CNPA distribution and the resulting effective temperature from applying a Stix fit to this distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The particle distributions of asymmetric kinetic electrostatic structures

We give the energy distributions of electrons and ions supporting a steady state electrostatic structure in a collisionless plasma. The electric potential of the structure is skew asymmetrically distributed in space. We show that the jump discontinuous, logarithmically singular electron and ion distributions may be reduced to elliptic integrals. We give the coefficients of the logarithmic terms and the jumps at the discontinuities and we show that they are reciprocally proportional. We calculate bounds for the potential skew asymmetry and show that these bounds are regulated by the boundary conditions of the particle distributions. Despite singularities, our treatment reproduces a smooth space distribution of the potential amplitude and electron and ion distributions that are smooth at one of the boundaries of the electrostatic structure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of ionization distribution on the low frequency oscillations mode in Hall thrusters

It is found that the discharge parameters have notable effects on the mode of discharge current low frequency oscillation in Hall thrusters, but different discharge parameters might form the similar low frequency oscillation mode. In order to study the mechanism of oscillation mode formation, the ionization distribution in the discharge channel was measured experimentally, and one-dimensional quasi-neutrality hydrodynamic model was used to study the relationship between ionization distribution and the oscillation mode. Researches show that the low frequency oscillation with a narrow and condensed ionization distribution has the mode of lower amplitude and scattered frequency. The low frequency oscillation amplitude would become high and have dominative frequency component with the relative wide ionization distribution. Therefore, it can be concluded that the difference of ionization distribution characteristics is the main reason of the oscillation mode variation, and discharge parameters are only the external control parameters of ionization distribution characteristics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stationary electron velocity distribution function in crossed electric and magnetic fields with collisions

Analytical studies and numerical simulations show that the electron velocity distribution function in a Hall thruster discharge with crossed electric and magnetic fields is not Maxwellian. This is due to the fact that the mean free path between collisions is greater than both the Larmor radius and the characteristic dimensions of the discharge channel. However in numerical models of Hall thrusters, a hydrodynamic approach is often used to describe the electron dynamics, because discharge simulation in a fully kinetic approach requires large computing resources and is time consuming. A more accurate modeling of the electron flow in the hydrodynamic approximation requires taking into account the non-Maxwellian character of the distribution function and finding its moments, an approach that reflects the properties of electrons drifting in crossed electric and magnetic fields better than the commonly used Euler or Navier-Stokes approximations. In the present paper, an expression for the electron velocity distribution function in rarefied spatially homogeneous stationary plasma with crossed electric and magnetic fields and predominance of collisions with heavy particles is derived in the relaxation approximation. The main moments of the distribution function including longitudinal and transversal temperatures, the components of the viscous stress tensor, and of the heat flux vector are calculated. Distinctive features of the hydrodynamic description of electrons with a strongly non-equilibrium distribution function and the prospects for further development of the proposed approach for calculating the distribution function in spatially inhomogeneous plasma are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterizing the energy distribution of laser-generated relativistic electrons in cone-wire targets

Transport of relativistic electrons in a solid Cu wire target has been modeled with the implicit hybrid particle-in-cell code LSP to investigate the electron energy distribution and energy coupling from the high-intensity, short-pulse laser to electrons entering to the wire. Experiments were performed on the TITAN laser using a 1.5 mm long Cu wire attached to a Au cone tip at the laser intensity of 1 Multiplication-Sign 10{sup 20} W/cm{sup 2} which was irradiated into the cone. The simulated Cu K{alpha} wire profile and yields matched the measurements using a two-temperature energy distribution. These modeling results show that the cold component of the energy spectrum can be determined with {+-}100 keV accuracy from the fit to the initial experimental fall-off of the K{alpha} emission while the simulated profiles were relatively insensitive to the hotter component of the electron distribution (>4 MeV). The slope of measured escaped electrons was used to determine the hotter temperature. Using exponential energy distributions, the laser-to-electron-in-wire coupling efficiencies inferred from the fits decreased from 3.4% to 1.5% as the prepulse energy increases up to 1 J. The comparison of the energy couplings using the exponential and Relativistic Maxwellian distribution functions showed that the energy inferred in the cold component is independent of the type of the distribution function.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Formation of electron kappa distributions due to interactions with parallel propagating whistler waves

In space plasmas, charged particles are frequently observed to possess a high-energy tail, which is often modeled by a kappa-type distribution function. In this work, the formation of the electron kappa distribution in generation of parallel propagating whistler waves is investigated using fully nonlinear particle-in-cell (PIC) simulations. A previous research concluded that the bi-Maxwellian character of electron distributions is preserved in PIC simulations. We now demonstrate that for interactions between electrons and parallel propagating whistler waves, a non-Maxwellian high-energy tail can be formed, and a kappa distribution can be used to fit the electron distribution in time-asymptotic limit. The κ-parameter is found to decrease with increasing initial temperature anisotropy or decreasing ratio of electron plasma frequency to cyclotron frequency. The results might be helpful to understanding the origin of electron kappa distributions observed in space plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗