Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper presents the analysis which help visualize the DER impact on the grid, identify the challenges and provides an insight into the new distribution management and control needs to enable reliable and resilient grid operations.

behind-the-meter↗

Electricity Capacity Expansion Modeling, Analysis, and Visualization. A Summary of High-Renewable Modeling Experience for China

Mathematical and computational models are widely used for the analysis and design of both physical and financial systems. Modeling the electric grid is of particular importance to China for three reasons. First, power-sector assets are expensive and long-lived, and they are critical to any country's development. China's electric load, transmission, and other energy-related infrastructure are expected to continue to grow rapidly; therefore it is crucial to understand and help plan for the future in which those assets will operate (NDRC ERI 2015). Second, China has dramatically increased its deployment of renewable energy (RE), and is likely to continue further accelerating such deployment over the coming decades. Careful planning and assessment of the various aspects (technical, economic, social, and political) of integrating a large amount of renewables on the grid is required. Third, companies need the tools to develop a strategy for their own involvement in the power market China is now developing, and to enable a possible transition to an efficient and high RE future.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Peak load reduction and load shaping in HVAC and refrigeration systems in commercial buildings by using a novel lightweight dynamic priority-based control strategy

Reducing peak power demand in a building can reduce electricity expenses for the building owner and contribute to the efficiency and reliability of the electrical power grid. For the building owner, reduced expenses come from the reduction or elimination of peak power charges on electricity bills. For the power system operator, reducing peak power demand leads to a more predictable load profile and reduces stress on the electric grid system. Herein we present a computationally inexpensive, dynamic, and retrofit-deployable control strategy to effect peak load reduction and load shaping. The effectiveness of the control strategy is examined in a simulation with 80 air-conditioning units and 40 refrigeration units. The results show that a peak demand reduction of 60 kW can be achieved relative to peak demand in a typical set point–based approach. The proposed strategy was deployed in a gymnasium building with four rooftop HVAC units, where it showed over 15% peak demand (kW) reduction savings while maintaining or lowering energy consumption (in kilowatt-hours) relative to the set point–based thermostat controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reduced-Order Structure-Preserving Model for Parallel-Connected Three-Phase Grid-Tied Inverters: Preprint

Given that next-generation infrastructures will contain large numbers of grid-connected inverters and these interfaces will be satisfying a growing fraction of system load, it is imperative to analyze the impacts of power electronics on such systems. However, since each inverter model has a relatively large number of dynamic states, it would be impractical to execute complex system models where the full dynamics of each inverter are retained. To address this challenge, we derive a reduced-order structure-preserving model for parallel-connected grid-tied three-phase inverters. Here, each inverter in the system is assumed to have a full-bridge topology, LCL filter at the point of common coupling, and the control architecture for each inverter includes a current controller, a power controller, and a phase-locked loop for grid synchronization. We outline a structure-preserving reduced-order inverter model for the setting where the parallel inverters are each designed such that the filter components and controller gains scale linearly with the power rating. By structure preserving, we mean that the reduced-order three-phase inverter model is also composed of an LCL filter, a power controller, current controller, and PLL. That is, we show that the system of parallel inverters can be modeled exactly as one aggregated inverter unit and this equivalent model has the same number of dynamical states as an individual inverter in the paralleled system. Numerical simulations validate the reduced-order models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Semi-Supervised, Non-Intrusive Disaggregation of Nodal Load Profiles With Significant Behind-the-Meter Solar Generation

It is of imperative interests for regional transmission organizations (RTOs) to effectively extract actual load profiles at transmission nodes with significant behind-the-meter solar generation, which remains a gap in the existing technology paradigm. This paper proposes an explicit yet efficient linear estimator to disaggregate actual load profiles at transmission buses with significant behind-the-meter (BTM) solar generations. The proposed estimator is based on disaggregating (i.e., extracting) at locations close to transmission buses under consideration. Further, to overcome the lack of “ground truth” and validate the performance of the proposed algorithms, we first propose semi-supervised mechanisms with parameter tuning as well as unsupervised clustering and leverage the unique characteristics of zero-crossing points in BTM solar peaking behaviors, which we refer to as “Zone-to-Node (Z2N)” methods. Next, we further propose a bi-level Node-to-Node (N2N) framework that improves the overall disaggregation performances compared to Z2N. Numerical results are presented using real-world data at PJM Interconnection.

14 SOLAR ENERGY↗

Dynamic simulation and load-following control of an integrated gasification combined cycle (IGCC) power plant with CO{sub 2} capture

Load-following control of future integrated gasification combined cycle (IGCC) plants with pre-combustion CO{sub 2} capture is expected to be far more challenging as electricity produced by renewable energy is connected to the grid and strict environmental limits become mandatory requirements. To study control performance during load following, a plant-wide dynamic simulation of a coal-fed IGCC plant with CO{sub 2} capture has been developed. The slurry-fed gasifier is a single-stage, downward-fired, oxygen-blown, entrained-flow type with a radiant syngas cooler (RSC). The syngas from the outlet of the RSC goes to a scrubber followed by a two-stage sour shift process with inter-stage cooling. The acid gas removal (AGR) process is a dual-stage physical solvent-based process for selective removal of H{sub 2}S in the first stage and CO{sub 2} in the second stage. Sulfur is recovered using a Claus unit with tail gas recycle to the AGR. The recovered CO{sub 2} is compressed by a split-shaft multistage compressor and sent for sequestration after being treated in an absorber with triethylene glycol for dehydration. The clean syngas is sent to two advanced “F”-class gas turbines (GTs) partially integrated with an elevated-pressure air separation unit. A subcritical steam cycle is used for heat recovery steam generation. A treatment unit for the sour water strips off the acid gases for utilization in the Claus unit. The steady-state model developed in Aspen Plus® is converted to an Aspen Plus Dynamics® simulation and integrated with MATLAB® for control studies. The results from the plant-wide dynamic model are compared qualitatively with the data from a commercial plant having different configuration, operating condition, and feed quality than what has been considered in this work. For load-following control, the GT-lead with gasifier-follow control strategy is considered. A modified proportional–integral–derivative (PID) control is considered for the syngas pressure control. For maintaining the desired CO{sub 2} capture rate while load-following, a linear model predictive controller (LMPC) is implemented in MATLAB®. A combined process and disturbance model is identified by considering a number of model forms and choosing the final model based on an information-theoretic criterion. The performance of the LMPC is found to be superior to the conventional PID control for maintaining CO{sub 2} capture rates in an IGCC power plant while load following.

01 COAL, LIGNITE, AND PEAT↗

Transient Two-Dimensional Analysis of Side Load in Liquid Rocket Engine Nozzles

Two-dimensional planar and axisymmetric numerical investigations on the nozzle start-up side load physics were performed. The objective of this study is to develop a computational methodology to identify nozzle side load physics using simplified two-dimensional geometries, in order to come up with a computational strategy to eventually predict the three-dimensional side loads. The computational methodology is based on a multidimensional, finite-volume, viscous, chemically reacting, unstructured-grid, and pressure-based computational fluid dynamics formulation, and a transient inlet condition based on an engine system modeling. The side load physics captured in the low aspect-ratio, two-dimensional planar nozzle include the Coanda effect, afterburning wave, and the associated lip free-shock oscillation. Results of parametric studies indicate that equivalence ratio, combustion and ramp rate affect the side load physics. The side load physics inferred in the high aspect-ratio, axisymmetric nozzle study include the afterburning wave; transition from free-shock to restricted-shock separation, reverting back to free-shock separation, and transforming to restricted-shock separation again; and lip restricted-shock oscillation. The Mach disk loci and wall pressure history studies reconfirm that combustion and the associated thermodynamic properties affect the formation and duration of the asymmetric flow.

Wang, Ten-See↗

Near-Term Electricity Requirement and Emission Implications for Sustainable Aviation Fuel Production with CO 2 -to-Fuels Technologies

Aviation contributed approximately 10% of the U.S. transportation sector's greenhouse gas (GHG) emissions and about 3% of the nation's total GHG production before the coronavirus disease (COVID-19) pandemic (EPA 2022). Unlike the ground transportation sector, which can be decarbonized by using batteries and hydrogen fuel cell powertrain technologies, the technical and economic challenges of aviation electrification open the opportunity for CO 2 utilization (CO2U) using clean power sources. The U.S. government set a goal to produce 3 billion gallons per year of sustainable aviation fuels (SAF) by 2030 and scale up the production to 35 billion gallons per year by 2050 (Bioenergy Technologies Office 2022). In this report, we examine three potential locations, in California, Iowa, and Louisiana, for SAF production using two production pathways that are expected to be available by 2030. We analyze the electricity cost to satisfy 10% of the SAF production potential for the select locations. Specifically, we consider (1) retail electricity cost from the default local utility in each location; (2) physical power purchase agreement (PPA) for renewable power and battery storage hybrid systems with preset prices; (3) financial PPA from a dedicated renewable plant; and (4) estimated real-time pricing (RTP) from the wholesale power market with utility delivery adders. Retail rates are available for the three potential locations; however, the developer should negotiate with the local utility in Iowa for new tariff riders, because the load of the proposed SAF plant (1.4 GW) is significantly higher than the current industrial tariff structure requirement (200 kW). The developers are not able to claim federal credits (i.e., the Inflation Reduction Act of 2022) when sourcing electricity from local utilities. Developers could consider prioritizing physical and financial PPAs as purchase options. While physical PPAs can be imported out of state, this structure imposes availability issues as developers must locate in the same electricity grid regions. Financial PPAs do not have the same location restrictions and provide the same cost savings as physical PPAs, but financial PPAs impose financial risks in the event of system curtailment and grid interruption. RTPs are available for customers in California with flexible load and hourly load management capability; however, utilities in our studied regions in Louisiana and Iowa only offer time-of-use and curtailment programs to incentivize lower energy usage in peak hours. These utilities do not currently offer RTP programs, and the developer may need to have further negotiations with the local utilities to access RTP programs. The results show that purchased electricity prices may range from 2.6 cents/kWh to 7.1 cents/kWh for the three studied plants.

02 PETROLEUM↗

Energy Research at Idaho National Laboratory

Energy-related research at Idaho National Laboratory (INL) takes many forms. In this presentation, Liam Boire will step through a specific, on-going research project at INL which seeks to understand transmission grid resilience, and the components which can be improved to increase the resilience of our electrical infrastructure. While utilities and researchers similarly strive to improve power grid reliability, the frequency of large power outages are increasing. Thus, the importance for developing efficient methodologies that enable utilities and researchers alike to identify the most effective areas for improvement within the electric grid is more critical than ever. The method developed during this project recognized that a variety of factors were important to consider when identifying areas for improvement in the electric grid. Physics-based simulators are able to calculate voltage stability, load draws and generation capacities, and enumerate the combinations of component failures which result in system-wide failures (blackout scenarios). Probabilistic Risk Assessment (PRA) is able to assign probabilities to these failure scenarios based on typical component data (or more specific data if a specific system is being analyzed), and thus prioritize the list of failure scenarios based on likelihood and the components based on importance. Finally, adaptive capacity models can simulate the candidate grid and evaluate real and reactive power generation versus demand over time, calculating the total adaptive capacity available in various regions of the grid. The less adaptive capacity a region has, the less “buffer” that region has from failure. Not only are the individual results of these analyses valuable in understanding grid resilience, but the results of these analyses can be cross-correlated for deeper insight. When a grid is analyzed with this approach, failure scenarios can be enumerated and ranked by likelihood, components can be ranked by likelihood to drive system-wide failure, regions can be evaluated for adaptive capacity, and sensitive regions can be identified by recognizing the locations of important components within sensitive regions. Following this detailed discussion, a brief overview of some of the other energy research and areas of interest for the lab will be presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Controlling Air Conditioners for Frequency Regulation: A Real-World Example

Even though thermostatically controlled loads like air conditioners present a great potential for providing ancillary services to the electric power grid, the practical challenges associated with their real-time coordination have not received the necessary attention. In this work, we present a nondisruptive load control application, specifically, we demonstrate how real residential air conditioners can provide frequency regulation. Aggregate power adjustment is achieved by modifying the ON/OFF modes of the air conditioners. To account for both single and multi-zone houses, we extend the currently available techniques and develop an approach that can be used for controlling aggregations that include both types of houses. A discussion of the practical challenges encountered in our field experiments is provided, along with the hardware and software approaches we developed to circumvent them. Here, we argue that limitations of current thermostat APIs introduce significant challenges and are an impediment to widespread adoption of fast load control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and analysis of grid stiffened concepts for aircraft composite primary structural applications

An approach to buckling resistant design of general grid stiffened flat plates based on smeared stiffener theory for combined inplane loading is discussed. Some results from parametric studies performed to assess the validity of smeared stiffener for practical stiffener configurations and to illustrate the benefits of different stiffening concepts are given. Details of a design study are discussed where the present analysis method is used to design a grid stiffened panel for a fuselage application and verified using a finite element analysis results.

Ambur, Damodar R.↗

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer↗

Metrics and Analytical Frameworks for Valuing Energy Efficiency and Distributed Energy Resources in the Built Environment: Preprint

This paper summarizes efforts to develop new—and enhance existing—analytical frameworks and metrics to quantify the value that grid-interactive efficient homes with solar (GEB-solar homes) can provide. Industry is working to characterize and understand these capabilities and benefits, but existing analytical frameworks for evaluating energy efficiency (EE) are often siloed from those that evaluate distributed energy resources (DERs). Five metrics were adapted from an extensive literature review and applied to case studies of a modeled home in Riverside, California: ramp up/down, cover factor demand/supply, and curtailable load. Eight different technology scenarios were analyzed using a more tightly connected suite of building-to-grid models (BEopt, REopt, ReEDS, and PLEXOS). Additionally, an initial version of the Cambium tool was developed, characterizing the marginal prices and emissions from NREL’s 2018 Standard Scenarios. These grid costs were extended to a time-varying proxy retail rate and applied as part of a new grid alignment metric. In the results, a more integrated combination of GEB-solar technologies led to a higher cover factor demand—the percentage of gross home load covered by on-site solar—however, a benchmark was required to determine what range of cover factor was “best” for given grid conditions. To that end, a grid alignment cost metric was applied to the case study scenarios. The average cost to serve the net load of the home decreased from a median of ~$0.24/kWh to ~$0.10/kWh when the most integrated technology scenario was optimized towards the grid pricing proxy versus the time-of-use (TOU) rate.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Permanent Electrical Loads in New Homes

Numerous electrical products and components are installed by the builder during construction and prior to occupancy. Some of these components are required by safety codes, such as smoke detectors, others are needed to support the communications infrastructure, and still others provide features that future occupants will find useful, such as remotely controlled garage door openers. We compiled a list of over 50 builder-installed devices that are likely to have continuous power consumption, and measured the power consumptions for a smaller group. A procedure to measure these loads in a home was developed based on readings from the smart meter. A typical American home can easily have 80 W of continuous power – over 650 kWh/year – devoted to these components. New homes are likely to have more of these devices and higher loads. Techniques to reduce this energy use include: selection of lowest-power solutions when a range of power consumptions are available, more efficient circuitry and power management, a separate DC circuit to serve DC-powered appliances, and use of energyscavenging sensors and controls in place of grid-powered components. A protocol to define and measure builder-installed loads, along with a recommended ceiling, might also stimulate savings.

Meier, Alan↗

AVESTAR Center for Operational Excellence of Electricity Generation Plants

To address industry challenges in attaining operational excellence for electricity generation plants, the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) has launched a world-class facility for Advanced Virtual Energy Simulation Training and Research (AVESTARTM). This presentation will highlight the AVESTARTM Center simulators, facilities, and comprehensive training, education, and research programs focused on the operation and control of high-efficiency, near-zero-emission electricity generation plants. The AVESTAR Center brings together state-of-the-art, real-time, high-fidelity dynamic simulators with full-scope operator training systems (OTSs) and 3D virtual immersive training systems (ITSs) into an integrated energy plant and control room environment. AVESTAR’s initial offering combines--for the first time--a “gasification with CO2 capture” process simulator with a “combined-cycle” power simulator together in a single OTS/ITS solution for an integrated gasification combined cycle (IGCC) power plant with carbon dioxide (CO2) capture. IGCC systems are an attractive technology option for power generation, especially when capturing and storing CO2 is necessary to satisfy emission targets. The AVESTAR training program offers a variety of courses that merge classroom learning, simulator-based OTS learning in a control-room operations environment, and immersive learning in the interactive 3D virtual plant environment or ITS. All of the courses introduce trainees to base-load plant operation, control, startups, and shutdowns. Advanced courses require participants to become familiar with coordinated control, fuel switching, power-demand load shedding, and load following, as well as to problem solve equipment and process malfunctions. Designed to ensure work force development, training is offered for control room and plant field operators, as well as engineers and managers. Such comprehensive simulator-based instruction allows for realistic training without compromising worker, equipment, and environmental safety. It also better prepares operators and engineers to manage the plant closer to economic constraints while minimizing or avoiding the impact of any potentially harmful, wasteful, or inefficient events. The AVESTAR Center is also used to augment graduate and undergraduate engineering education in the areas of process simulation, dynamics, control, and safety. Students and researchers gain hands-on simulator-based training experience and learn how the commercial-scale power plants respond dynamically to changes in manipulated inputs, such as coal feed flow rate and power demand. Students also analyze how the regulatory control system impacts power plant performance and stability. In addition, students practice start-up, shutdown, and malfunction scenarios. The 3D virtual ITSs are used for plant familiarization, walk-through, equipment animations, and safety scenarios. To further leverage the AVESTAR facilities and simulators, NETL and its university partners are pursuing an innovative and collaborative R&D program. In the area of process control, AVESTAR researchers are developing enhanced strategies for regulatory control and coordinated plant-wide control, including gasifier and gas turbine lead, as well as advanced process control using model predictive control (MPC) techniques. Other AVESTAR R&D focus areas include high-fidelity equipment modeling using partial differential equations, dynamic reduced order modeling, optimal sensor placement, 3D virtual plant simulation, and modern grid. NETL and its partners plan to continue building the AVESTAR portfolio of dynamic simulators, immersive training systems, and advanced research capabilities to satisfy industry’s growing need for training and experience with the operation and control of clean energy plants. Future dynamic simulators under development include natural gas combined cycle (NGCC) and supercritical pulverized coal (SCPC) plants with post-combustion CO2 capture. These dynamic simulators are targeted for use in establishing a Virtual Carbon Capture Center (VCCC), similar in concept to the DOE’s National Carbon Capture Center for slipstream testing. The VCCC will enable developers of CO2 capture technologies to integrate, test, and optimize the operation of their dynamic capture models within the context of baseline power plant dynamic models. The objective is to provide hands-on, simulator-based “learn-by-operating” test platforms to accelerate the scale-up and deployment of CO2 capture technologies. Future AVESTAR plans also include pursuing R&D on the dynamics, operation, and control of integrated electricity generation and storage systems for the modern grid era. Special emphasis will be given to combining load-following energy plants with renewable and distributed generating supplies and fast-ramping energy storage systems to provide near constant baseload power.

97 MATHEMATICS AND COMPUTING↗

Microgrids with dynamically configurable boundaries including multiple main grid feeder coupling locations and methods of operating the same

An energy system includes a microgrid including a network of at least one distributed energy resource and a plurality of loads, the at least one distributed energy resource being configured to supply power to the plurality of loads. The microgrid is configurable to connect to one of a plurality of feeder circuits of a main power grid at one of a plurality of coupling interface locations, respectively. The microgrid is also configurable to expand or shrink its power supply area according to the available power generation capabilities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Interdisciplinary Education through “Edutainment”: Electric Grid Resilient Control Systems Course

As energy companies and governments attempt to get more from the existing power grid and other critical infrastructures, more automatic control systems are being applied 1-2. With this greater reliance on network-based, digital automation and the stresses of pressing existing infrastructure for greater performance, the power grid and underlying systems have become more susceptible to both malicious attacks and unexpected, natural threats. Governments and other stakeholders have chosen to address infrastructure issues by the implementation of a smarter grid. In the smart grid, operators and control systems supervise power generation, distribution, transmission, and loads to utilize these assets most efficiently3. Such extensive monitoring and control over a distributed system cause complexity that challenge systems designers and human operators in new ways. In addition, cyber vulnerability of these systems has been illustrated in many recent articles on malicious attacks to electric power systems and other similar infrastructure for natural gas, water and communications4. It is therefore critical in the next generation of control systems that resilience plays a large and critical role in the grid design and development. Resilient control systems is a field of research that seeks solutions to the complexity through a holistic approach that combines cognitive science, computer security, communications, and control systems. To enable future researchers and practitioners to assist with designing more resilient systems, science, technology, engineering and mathematics education needs to incorporate interdisciplinary topics. While electrical engineering and computer science programs in the nation include a cyber-security perspective, few if any have focused on the unique control system aspects. Human cognitive aspects are most definitely not addressed in technology education discourse. To this end, a class and education tools in resilient control systems have been created.

17 WIND ENERGY↗

End-Use Load Profiles for the U.S. Building Stock: Technical Advisory Group Meeting #11

A technical advisory group guided the End-Use Load Profiles dataset development to ensure that the direction and outcomes of the work were aligned with market needs. The technical advisory group included roughly 100 representatives from organizations that were likely to use the resulting load profiles in their work, including utility companies, utility program implementers, grid operators, consultancies, research centers, state regulatory agencies, and regional energy efficiency organizations. This is the presentation from TAG Meeting #11.

buildings↗