Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Voltage Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Probing Sensitivity of Discharge Characteristics to Model Selection using Uncertainty Quantification in an aprotic Li-Oxygen Battery

Currently, there are several models in the literature, such as kinetic models, microstructural models, and mass transport models that describe a Li-air battery's discharge behavior. Many of these models are calibrated and tested at low current densities and cannot be easily transferred to high current densities. Even at low current densities, there is no quantitative method for a researcher to choose a reaction kinetic model such as classical Butler-Volmer and its derivatives, and modified Marcus-Hush-Chidsey, a resistance model for lithium peroxide such as electron transport via tunneling or linear resistivity, a surface coverage model (lithium peroxide growth) such as partial coverage or full coverage, and mass transport model (discussed in Ref. [1]). Also, it is time-consuming to test different models at high current density (1C) due to a lack of well-tested models and well-calibrated model parameters. For this presentation, we will develop an analytical model, which acts as a surrogate model for a sophisticated finite element model to predict discharge time and discharge voltage. Next, we use an uncertainty quantifying technique called reduced-order stochastic optimization [2, 3] to determine the uncertainty in model parameters for rate kinetics, lithium peroxide resistivity, and parasitic resistance. Finally, a finite element simulation is performed to determine the error introduced by the surrogate model and its influence on the uncertainty in the model parameters.

M Mehta↗

Influence of Intense Beam in High Pressure Hydrogen Gas Filled RF Cavities

The influence of an intense beam in a high-pressure gas filled RF cavity has been measured by using a 400 MeV proton beam in the Mucool Test Area at Fermilab. The ionization process generates dense plasma in the cavity and the resultant power loss to the plasma is determined by measuring the cavity voltage on a sampling oscilloscope. The energy loss has been observed with various peak RF field gradients (E), gas pressures (p), and beam intensities in nitrogen and hydrogen gases. Observed RF energy dissipation in single electron (dw) in N{sub 2} and H{sub 2} gases was 2 10{sup -17} and 3 10{sup -17} Joules/RF cycle at E/p = 8 V/cm/Torr, respectively. More detailed dw measurement have been done in H{sub 2} gas at three different gas pressures. There is a clear discrepancy between the observed dw and analytical one. The discrepancy may be due to the gas density effect that has already been observed in various experiments.

43 PARTICLE ACCELERATORS↗

Testing and Analysis for Lifetime Prediction of Crystalline Silicon PV Modules Undergoing Degradation by System Voltage Stress: Preprint

Acceleration factors are calculated for crystalline silicon PV modules under system voltage stress by comparing the module power during degradation outdoors to that in accelerated testing at three temperatures and 85% relative humidity. A lognormal analysis is applied to the accelerated lifetime test data considering failure at 80% of the initial module power. Activation energy of 0.73 eV for therate of failure is determined, and the probability of module failure at an arbitrary temperature is predicted. To obtain statistical data for multiple modules over the course of degradation in-situ of the test chamber, dark I-V measurements are obtained and transformed using superposition, which is found well suited for rapid and quantitative evaluation of potential-induced degradation. It isdetermined that shunt resistance measurements alone do not represent the extent of power degradation. This is explained with a two-diode model analysis that shows an increasing second diode recombination current and ideality factor as the degradation in module power progresses. Failure modes of the modules stressed outdoors are examined and compared to those stressed in accelerated tests.

14 SOLAR ENERGY↗

Preliminary Measurements of Partial Discharge Inception Voltage Degradation with Constant Temperature Aging of Magnet Wire Twisted Pairs for Electric Aircraft Motors

Electric aircraft require high reliability electric motors to meet the stringent safety standards of the aviation industry. Motor winding insulation lifetime and reliability models for electric aircraft applications are needed to enable design of high reliability and high-performance electric motors for aviation applications. Three primary stresses effect the lifetime of motor winding insulation: thermochemical, mechanical, and electrical. This paper presents preliminary experiments on twisted pairs of magnet wire targeting understanding the thermo-chemical degradation of motor winding insulation through constant temperature thermal aging. Three types of magnet wire twisted pairs where tested: polyimide insulated magnet wire, epoxy coated polyimide insulated magnet wire, and epoxy potted polyimide magnet wire. The degradation of the samples over time at temperature was tracked using partial discharge inception voltage measurements. These initial experiments were used for development of procedures and expertise in partial discharge testing and thermo-chemical aging to inform future testing. The preliminary nature of these experiments should be noted when viewing the results. Lessons learned from the experiments are documented.

Thomas Tallerico↗

Development and Testing of a High Level Axial Array Duct Sound Source for the NASA Flow Impedance Test Facility

In this report both a frequency domain method for creating high level harmonic excitation and a time domain inverse method for creating large pulses in a duct are developed. To create controllable, high level sound an axial array of six JBL-2485 compression drivers was used. The pressure downstream is considered as input voltages to the sources filtered by the natural dynamics of the sources and the duct. It is shown that this dynamic behavior can be compensated for by filtering the inputs such that both time delays and phase changes are taken into account. The methods developed maximize the sound output while (i) keeping within the power constraints of the sources and (ii) maintaining a suitable level of reproduction accuracy. Harmonic excitation pressure levels of over 155dB were created experimentally over a wide frequency range (1000-4000Hz). For pulse excitation there is a tradeoff between accuracy of reproduction and sound level achieved. However, the accurate reproduction of a pulse with a maximum pressure level over 6500Pa was achieved experimentally. It was also shown that the throat connecting the driver to the duct makes it difficult to inject sound just below the cut-on of each acoustic mode (pre cut-on loading effect).

Johnson, Marty E.↗

The effect of cobalt doping on the morphology and electrochemical performance of high-voltage spinel LiNi 0.5 Mn 1.5 O 4 cathode material

In this paper, to reveal the effects of Co-doping on the electrochemical performance of micro-sized LiNi 0.5 Mn 1.5 O 4 (LNMO), undoped LNMO and Co-doped LiCo 0.1 Ni 0.45 Mn 1.45 O 4 (LCoNMO) are synthesized via a PVP-combustion method and calcined at 1000 °C for 6 h. SEM and XRD analyses suggest that Co-doping decreases the particle size and the Li z Ni 1-z O 2 impurity at the calcination temperature of 1000 °C. LCoNMO has much better rate capability while its specific capacity at C/5 is 10% lower than that of LNMO. At 15 C rate, their specific capacities are closed, and the LCoNMO delivers 86.2% capacity relative to C/5, and this value for LNMO is only 77.0%. The D Li + values determined by potential intermittent titration technique (PITT) test of LCoNMO are 1–2 times higher than that of LNMO in most SOC region. The LCoNMO shows very excellent cycling performance, which is the best value compared with literatures. After 1000 cycles, the LCoNMO still delivers 94.1% capacity. Finally, moreover, its coulombic efficiency and energy efficiency keep at 99.84% and over 97.3% during 1 C cycling, respectively.

36 MATERIALS SCIENCE↗

EVs@Scale Lab Consortium High-Power Charging Pillar Deep-Dive Technical Meeting

Managed under the the U.S. Department of Energy (DOE)-funded EVs@Scale Consortium, the High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project aims to create an experimental platform for integration and control approaches in a direct current (DC), distribution-based high-power charging (HPC) system. The eCHIP project addresses the crucial need to design and validate efficient, low-cost, reliable, and interoperable solutions for a DC-coupled charging hub ("DC hub" for short). This report explains the design, development, and implementation process of an experimental platform for the DC hub. DC distribution holds significant potential for enhancing the operation of an HPC station architecture. However, there are challenges in establishing a DC hub, including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and a lack of common system-level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products, as well as novel, in-house designed solutions, to evaluate different use cases at rated power and voltage levels. The developed proof-of-concept charging platform and open-source SEMS allow the development and testing of various controllers and chargers from different vendors. The DC hub platform integrated EVs, an ESS, a PV system, and building load to demonstrate the flexibility of the platform. The open-source SEMS controlled the devices within the hub using a rule-based implementation, realizing available standards.

ADVANCED PROPULSION SYSTEMS↗

Plasma And Beam Homogeneity Of The RF-Driven Negative Hydrogen Ion Source For ITER NBI

The neutral beam injection (NBI) system of ITER is based on a large RF driven negative hydrogen ion source. For good beam transmission ITER requires a beam homogeneity of better than 10%. The plasma uniformity and the correlation with the beam homogeneity are being investigated at the prototype ion sources at IPP. Detailed studies are carried out at the long pulse test facility MANITU with a source of roughly 1/8 of the ITER source size. The plasma homogeneity close to plasma grid is measured by optical emission spectroscopy and by fixed Langmuir probes working in the ion saturation region. The beam homogeneity is measured with a spatially resolved H{sub {alpha}} Doppler-shifted beam spectroscopy system. The plasma top-to-bottom symmetry improves with increasing RF power and increasing bias voltage which is applied to suppress the co-extracted electron current. The symmetry is better in deuterium than in hydrogen. The boundary layer near the plasma grid determines the plasma symmetry. At high ion currents with a low amount of co-extracted electrons the plasma is symmetrical and the beam homogeneity is typically 5-10%(RMS). The size scaling and the influence of the magnetic field strength of the filter field created by a plasma grid current is studied at the test facility RADI (roughly a 1/2 size ITER source) at ITER relevant RF power levels. In volume operation in deuterium (non-cesiated source), the plasma illumination of the grid is satisfying.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microelectrode Arrays Measure Blocking of Voltage-Gated Calcium Ion Channels on Supported Lipid Bilayers Derived from Primary Neurons

Drug studies targeting neuronal ion channels are crucial to understand neuronal function and develop therapies for neurological diseases. The traditional method to study neuronal ion-channel activities heavily relies on the whole-cell patch clamp as the industry standard. However, this technique is both technically challenging and labour-intensive, while involving the complexity of keeping cells alive with low throughput. Therefore, the shortcomings are limiting the efficiency of ion-channel-related neuroscience research and drug testing. Here, this work reports a new system of integrating neuron membranes with organic microelectrode arrays (OMEAs) for ion-channel-related drug studies. This work demonstrates that the supported lipid bilayers (SLBs) derived from both neuron-like (neuroblastoma) cells and primary neurons are integrated with OMEAs for the first time. The increased expression of voltage-gated calcium (CaV) ion channels on differentiated SH-SY5Y SLBs compared to non-differentiated ones is sensed electrically. Also, dose-response of the CaV ion-channel blocking effect on primary cortical neuronal SLBs from rats is monitored. The dose range causing ion channel blocking is comparable to literature. This system overcomes the major challenges from traditional methods (e.g., patch clamp) and showcases an easy-to-test, rapid, ultra-sensitive, cell-free, and high-throughput platform to monitor dose-dependent ion-channel blocking effects on native neuronal membranes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of a microwave high-power reception-conversion array for wireless power transmission

Initial performance tests of a 24-sq m area array of rectenna elements are presented. The array is used as the receiving portion of a wireless microwave power transmission engineering verification test system. The transmitting antenna was located at a range of 1.54 km. Output dc voltage and power, input RF power, efficiency, and operating temperatures were obtained for a variety of dc load and RF incident power levels at 2388 MHz. Incident peak RF intensities of up to 170 mW/sq cm yielded up to 30.4 kW of dc output power. The highest derived collection-conversion efficiency of the array was greater than 80 percent.

Dickinson, R. M.↗

Lightning protection guidelines and test data for adhesively bonded aircraft structures

The highly competitive marketplace and increasing cost of energy has motivated manufacturers of general aviation aircraft to utilize composite materials and metal-to-metal bonding in place of conventional fasteners and rivets to reduce weight, obtain smoother outside surfaces and reduce drag. The purpose of this program is protection of these new structures from hazardous lightning effects. The program began with a survey of advance-technology materials and fabrication methods under consideration for future designs. Sub-element specimens were subjected to simulated lightning voltages and currents. Measurements of bond line voltages, electrical sparking, and mechanical strength degradation were made to comprise a data base of electrical properties for new technology materials and basic structural configurations. The second hase of the program involved tests on full scale wing structures which contained integral fuel tanks and which were representative of examples of new technology structures and fuel systems. The purpose of these tests was to provide a comparison between full scale structural measurements and those obtained from the sub-element specimens.

Pryzby, J. E.↗

National Renewable Energy Laboratory (NREL) Topic 2 Final Report: End-to-End Communication and Control System to Support Clean Energy Technologies

This document is the final report of a two-year development, test, and demonstration project, 'Cohesive Application of Standards- Based Connected Devices to Enable Clean Energy Technologies.' The project was part of the National Renewable Energy Laboratory's (NREL's) Integrated Network Testbed for Energy Grid Research and Technology (INTEGRATE) initiative hosted at Energy Systems Integration Facility (ESIF). This project demonstrated techniques to control distribution grid events using the coordination of traditional distribution grid devices and high-penetration renewable resources and demand response. Using standard communication protocols and semantic standards, the project examined the use cases of high/low distribution voltage, requests for volt-ampere-reactive (VAR) power support, and transactive energy strategies using Volttron. Open source software, written by EPRI to control distributed energy resources (DER) and demand response (DR), was used by an advanced distribution management system (ADMS) to abstract the resources reporting to a collection of capabilities rather than needing to know specific resource types. This architecture allows for scaling both horizontally and vertically. Several new technologies were developed and tested. Messages from the ADMS based on the common information model (CIM) were developed to control the DER and DR management systems. The OpenADR standard was used to help manage grid events by turning loads off and on. Volttron technology was used to simulate a homeowner choosing the price at which to enter the demand response market. Finally, the ADMS used newly developed algorithms to coordinate these resources with a capacitor bank and voltage regulator to respond to grid events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Grid Reliability Estimation via Adaptive Importance Sampling

Electricity production currently generates approximately 25% of greenhouse gas emissions in the USA. Thus, increasing the amount of renewable energy is a key step to carbon neutrality. However, integrating a large amount of fluctuating renewable generation is a significant challenge for power grid operating and planning. Grid reliability, i.e., an ability to meet operational constraints under power fluctuations, is probably the most important of them. In this letter, we propose computationally efficient and accurate methods to estimate the probability of line overflow, i.e., reliability constraints violation, under a known distribution of renewable energy generation. To this end, we investigate an importance sampling approach, a flexible extension of Monte-Carlo methods, which adaptively changes the sampling distribution to generate more samples near the reliability boundary. The approach allows to estimate overload probability in real-time based only on a few dozens of random samples, compared to thousands required by the plain Monte-Carlo. Our study focuses on high voltage direct current power transmission grids with linear reliability constraints on power injections and line currents. Herein, we propose a novel theoretically justified physics-informed adaptive importance sampling algorithm and compare its performance to state-of-the-art methods on multiple IEEE power grid test cases.

power system faults↗

Diagnosis of Factors Impacting Yield in Multilayer Devices for Superconducting Electronics

The ability to localize defects in order to understand failure mechanisms in complex superconducting electronics circuits, while operating at low temperature, does not yet exist. Here, this work applies thermally-induced voltage alteration (TIVA), to a biased superconducting electronics (SCE) circuit at ambient temperature. TIVA is a commonly used, laser-based failure analysis technique developed for silicon-based microelectronics. The non-operational circuit consisted of an arithmetic logic unit (ALU) in a high-frequency test bed designed at HYPRES and fabricated by MIT Lincoln Laboratory using their SFQ5ee process. Localized TIVA signals were correlated with reflected light images at the surface, and these sites were further investigated by scanning electron microscopy imaging of focused ion-beam cross-sections. The areas investigated, where prominent TIVA signals were observed, showed seams in the Nb wiring layers at contacts to Josephson junctions or inductors and/or disrupted junction morphologies. Finally, these results suggest that the TIVA technique can be used at ambient temperature to diagnose fabrication defects that may cause low temperature circuit failure.

36 MATERIALS SCIENCE↗

Quench Protection by Putting a Current-pulse Into a Coil Center-Tap in HTS Coils

Forty years ago, Lawrence Berkeley Laboratory (LBL) tested a pulsed current quench protection system for a high current density two-meter diameter two-layer solenoid at 4.5 K with a stored energy of 8.5 MJ. The energy needed to protect this magnet was 13.4 kJ from an electrolytic capacitor system charged to voltages 800 V. This method also involved the use of a well-coupled shorted secondary circuits and quench-back. The applicability of this quench protection method to HTS magnets operating at temperatures >25 K could be of interest. There are a number of questions that should be asked, as follows: 1) Can this method work for HTS coils operating at temperatures >25 K? 2) Are there batteries or capacitors that can store 2 MJ or more that have short enough discharge times for quench protection at voltages less than 2 kV? 3) Is this quench protection system cost low enough to be reasonable?

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Section IV.D.3 for DOE 2013 Annual Report: Novel Phosphazene-based Compounds to Enhance Safety and Stability of Cell Chemistries for High Voltage Applications (INL)

Electrolytes play a central role in performance and aging in most electrochemical systems. As automotive and grid applications place a higher reliance on electrochemical stored energy, it becomes more urgent to have electrolyte components that enable optimal battery performance while promoting battery safety and longevity. Safety remains a foremost concern for widespread utilization of Li-ion technology in electric-drive vehicles, especially as the focus turns to higher voltage systems (5V). This work capitalizes on the long established INL expertise regarding phosphazene chemistry, aimed at battery-viable compounds for electrolytes and electrodes that are highly tolerant to abusive conditions. This report showcases our 2013 work for the DOE applied battery research (ABR) program, wherein testing results are summarized for INL electrolytes and alternative anode materials.

25 ENERGY STORAGE↗

Tool Chain for Simulations of Bi-Filar Coil Winding for Fast Quench Protection

The advancement of high-field magnets utilizing high-temperature superconductors (HTS) brings about complex challenges, especially in quench detection and protection. Traditional methods often fall short due to the inherently slow quench propagation in HTS materials. One promising approach to overcome this involves using a bifilar winding configuration, where two conductors are placed side by side. Under normal operation, they function in series, but during a quench event, they switch to an anti-parallel mode. This shift reduces the differential inductance of the coil to near zero, enabling rapid current oscillations through a capacitor discharge. The resulting high-frequency current flow leads to swift, uniform heating, triggering a full-coil quench within microseconds. Moreover, the strong mutual coupling between the two windings significantly reduces electrical noise in voltage measurements. In this work, we explore the viability of this concept by designing, constructing, and testing a REBCO bifilar racetrack coil in liquid nitrogen. We also present a validated simulation model that closely mirrors the coil's dynamic behavior under these conditions, aligning well with experimental observations.

Jayathilaka, Rehan [Northern Illinois U.]↗

A voltage to frequency converter for astronomical photometry

A voltage to frequency converter (VFC) for general use with photomultipliers is described. For high light levels, when the dead-time corrections for a photon counter would be excessive, the VFC maintains a linear response and allows the recording of data at high time resolution. Results of laboratory tests are given for the signal-to-noise characteristics, linearity, stability, and transient response of the VFC when used in conjunction with EMI 9658 and RCA C31034 photomultipliers.

Dunham, E.↗