Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Leveraging Calibration Transfer Techniques for Remote Monitoring of Samarium and Europium in LiCl Using Laser-Induced Florescence Spectroscopy for Radioisotope Production Applications

Radioisotope production relies on complex chemical processes that must be performed in radiological hot cells or glove boxes because of the radioactive and otherwise hazardous materials being used. In these situations, optical sensors can provide real-time monitoring to users, which is unobtainable by more traditional methods. This study explores the use of calibration transfer methods to train a model on one instrument and date and then transfer it to another instrument of the same or different configuration on a different date. By performing laser-induced fluorescence measurements of Eu(III) and Sm(III) in 10 M LiCl over the course of 6 months using two disparate spectrometers and two different training sets, a strategy for calibrating and deploying models for online monitoring was established. Three transfer techniques were compared: direct standardization (DS), piecewise direct standardization (PDS), and external parameter orthogonalization (EPO). DS and PDS outperformed EPO for day-to-day transfers, and EPO was not effective for instrument-to-instrument transfers. Transferring the initial date’s full factorial model provided better prediction performance compared with retraining models the day of measurements using a D-optimal designed calibration set. For both day-to-day and instrument-to-instrument transfers, five Kennard–Stone selected samples were sufficient. Based on this choice, the initial-date, high-resolution spectrometer model was transferred to a lower-resolution, compact spectrometer 6 months later to monitor a simulated, real-time demonstration. Here, the combined predictions of the DS and PDS transferred models were able to accurately track the anticipated concentration profiles, maintaining root-mean-square error of prediction values below 10 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coordination Sphere of Lanthanide Aqua Ions Resolved with Ab Initio Molecular Dynamics and X-ray Absorption Spectroscopy

To resolve the fleeting structures of lanthanide Ln 3+ aqua ions in solution, we (i) performed the first ab initio molecular dynamics (AIMD) simulations of the entire series of Ln 3+ aqua ions in explicit water solvent using pseudopotentials and basis sets recently optimized for lanthanides and (ii) measured the symmetry of the hydrating waters about Ln 3+ ions (Nd 3+ , Dy 3+ , Er 3+ , Lu 3+ ) for the first time with extended X-ray absorption fine structure (EXAFS). EXAFS spectra were measured experimentally and generated from AIMD trajectories to directly compare simulation, which concurrently considers the electronic structure and the atomic dynamics in solution, with experiment. In this study, we performed a comprehensive evaluation of EXAFS multiple-scattering analysis (up to 6.5 Å) to measure Ln–O distances and angular correlations (i.e., symmetry) and elucidate the molecular geometry of the first hydration shell. This evaluation, in combination with symmetry-dependent L 3 - and L 1 -edge spectral analysis, shows that the AIMD simulations remarkably reproduces the experimental EXAFS data. The error in the predicted Ln–O distances is less than 0.07 Å for the later lanthanides, while we observed excellent agreement with predicted distances within experimental uncertainty for the early lanthanides. Our analysis revealed a dynamic, symmetrically disordered first coordination shell, which does not conform to a single molecular geometry for most lanthanides. This work sheds critical light on the highly elusive coordination geometry of the Ln 3+ aqua ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electronic spectra of the tetraphenylcyclobutadienecyclopentadienylnickel(II) cation and radical

In this study, properties of the tetraphenylcyclobutadienecyclopentadienylnickel(II) cation 1 and its tetra-o-fluoro derivative 1a have been measured and calculated. The B3LYP/TZP optimized geometry of the free cation 1 agrees with a single-crystal X-ray diffraction structure except that in the crystal one of the phenyl substituents is strongly twisted to permit a close-packing interaction of two of its hydrogens with a nearby BF – 4 anion. The low-energy parts of the solution electronic absorption and magnetic circular dichroism (MCD) spectra of 1 and 1a have been interpreted by comparison with TD-DFT (B3LYP/TZP) results. Reduction or pulse radiolysis lead to a neutral 19-electron radical, whose visible absorption and MCD spectra have been recorded and interpreted as well. The reduction is facilitated by ~0.1 V upon going from 1 to 1a

14 SOLAR ENERGY↗

Nanoscale Tracking of the High-Temperature Spin-State Transition in LaCoO 3

The high-temperature spin and electronic transitions in LaCoO 3 have recently been leveraged to create neuromorphic (brain-inspired) devices. While these devices have shown the potential for impactful functionality in next-generation computing systems, the nanoscale dynamics of the spin and electronic transitions that underlie their operation are not well understood. Inhomogeneities related to interfaces, electrode contacts, strain, and crystal defects can all affect device performance, making nanoscale characterization of the transitions essential for producing consistent and reliable devices. Here, we demonstrate the first nanoscale in situ measurement of the spin transition in LaCoO 3 at device-relevant temperatures (25–325 °C) over length scales of tens of nanometers using STEM-EELS. This measurement is enabled by an Al 2 O 3 coating, which prevents unwanted reduction of the LaCoO 3 specimen at high temperature and vacuum. The detailed understanding of LaCoO 3 transition dynamics enabled by such measurements will be crucial for optimizing LaCoO 3 -based neuromorphic devices and increasing reliability for real-world application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-Loss Charge Transfer Plasmons in Graphene/α-RuCl 3 Heterostructures Below 40 K

Charge transfer at material interfaces governs a wide range of physical properties, from electronic band structures to emergent collective excitations. In two-dimensional (2D) material heterostructures, charge transfer phenomena play important roles in enabling novel quantum phases, proximity effects, and tunable plasmonic responses. One representative charge transfer interface is formed between α-RuCl 3 , a van der Waals material with high electron affinity, and graphene. Significant charge transfer across this interface induces the formation of charge-transfer plasmon polaritons (CPPs), hybrid excitations between light and charge oscillations. However, previous studies found that as the charge transfer process takes place, α-RuCl 3 becomes lossy, which limits the quality factor of CPPs. Here, we investigate CPPs down to 10 K using a home-built scattering-type scanning near-field optical microscope (s-SNOM) optimized for low-temperature measurements. Our study reveals a dramatic suppression of plasmon loss channels below 40 K, contributing to a significant enhancement in the plasmonic quality factor. This reduction in loss is likely attributed to the blue shift of the correlation-induced Mott gap in α-RuCl 3 with decreasing temperature, along with the reduction of phonon scattering at low temperature. In conclusion, our results highlight the potential of using s-SNOM and CPPs to study complex 2D interfaces and reveal correlated electron dynamics in the underlying material.

36 MATERIALS SCIENCE↗

Uranium Single Particle Analysis for Simultaneous Fluorine and Uranium Isotopic Determinations via Laser-Induced Breakdown Spectroscopy/Laser Ablation–Multicollector–Inductively Coupled Plasma–Mass Spectrometry

Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Drop-on-demand sample delivery for studying biocatalysts in action at X-ray free-electron lasers

X-ray crystallography at X-ray free-electron laser (XFEL) sources is a powerful method for studying macromolecules at biologically relevant temperatures. Moreover, when combined with complementary techniques like X-ray emission spectroscopy (XES), both global structures and chemical properties of metalloenzymes can be obtained concurrently, providing new insights into the interplay between the protein structure/dynamics and chemistry at an active site. However, implementing such a multimodal approach can be compromised by conflicting requirements to optimize each individual method. In particular, the method used for sample delivery greatly impacts the data quality. We present here a new, robust way of delivering controlled sample amounts on demand using acoustic droplet ejection coupled with a conveyor belt drive that is optimized for crystallography and spectroscopy measurements of photochemical and chemical reactions over a wide range of time scales. Studies with photosystem II, the phytochrome photoreceptor, and ribonucleotide reductase R2 illustrate the power and versatility of this method.

59 BASIC BIOLOGICAL SCIENCES↗

Exploring 3D elastic-wave scattering at interfaces using high-resolution phased-array system

The elastic-wave scattering at interfaces, such as cracks, is essential for nondestructive inspections, and hence, understanding the phenomenon is crucial. However, the elastic-wave scattering at cracks is very complex in three dimensions since microscopic asperities of crack faces can be multiple scattering sources. We propose a method for exploring 3D elastic-wave scattering based on our previously developed high-resolution 3D phased-array system, the piezoelectric and laser ultrasonic system (PLUS). We describe the principle of PLUS, which combines a piezoelectric transmitter and a 2D mechanical scan of a laser Doppler vibrometer, enabling us to resolve a crack into a collection of scattring sources. Subsequently, we show how the 3D elastic-wave scattering in the vicinity of each response can be extracted. Here, we experimentally applied PLUS to a fatigue-crack specimen. We found that diverse 3D elastic-wave scattering occurred in a manner depending on the responses within the fatigue crack. This is significant because access to such information will be useful for optimizing inspection conditions, designing ultrasonic measurement systems, and characterizing cracks. More importantly, the described methodology is very general and can be applied to not only metals but also other materials such as composites, concrete, and rocks, leading to progress in many fields.

36 MATERIALS SCIENCE↗

Identifying the secondary electron cutoff in ultraviolet photoemission spectra for work function measurements of non-ideal surfaces

Abstract Absolute values of work functions can be determined in ultraviolet photoemission spectroscopy (UPS) by measuring the minimum kinetic energy of secondary electrons generated by a known photon energy. However, some samples can produce spectra that are difficult to interpret due to additional intensity below the true secondary electron cutoff. Disordered absorbates on elemental metals add small intensity below the onset for the transition metal surfaces studied, which can be attributed to energy losses after photoelectrons are generated. In contrast, spectra from WO 3−x films can produce multiple onsets with comparable intensity which do not fit this model. False onsets (in the context of work function measurements) can be minimized by optimizing experimental detection parameters including limiting analyzer acceptance angles and pass energy. True work functions can be identified by examining the onsets as the sample bias is varied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hollow waveguides with low intrinsic photoluminescence fabricated with Ta{sub 2}O{sub 5} and SiO{sub 2} films

A type of integrated hollow core waveguide with low intrinsic photoluminescence fabricated with Ta{sub 2}O{sub 5} and SiO{sub 2} films is demonstrated. Hollow core waveguides made with a combination of plasma-enhanced chemical vapor deposition SiO{sub 2} and sputtered Ta{sub 2}O{sub 5} provide a nearly optimal structure for optofluidic biofluorescence measurements with low optical loss, high fabrication yield, and low background photoluminescence. Compared to earlier structures made using Si{sub 3}N{sub 4}, the photoluminescence background of Ta{sub 2}O{sub 5} based hollow core waveguides is decreased by a factor of 10 and the signal-to-noise ratio for fluorescent nanobead detection is improved by a factor of 12.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of two-dimensional hexagonal boron nitride using scanning electron and scanning helium ion microscopy

Characterization of the structural and physical properties of two-dimensional (2D) materials, such as layer number and inelastic mean free path measurements, is very important to optimize their synthesis and application. In this study, we characterize the layer number and morphology of hexagonal boron nitride (h-BN) nanosheets on a metallic substrate using field emission scanning electron microscopy (FE-SEM) and scanning helium ion microscopy (HIM). Using scanning beams of various energies, we could analyze the dependence of the intensities of secondary electrons on the thickness of the h-BN nanosheets. Based on the interaction between the scanning particles (electrons and helium ions) and h-BN nanosheets, we deduced an exponential relationship between the intensities of secondary electrons and number of layers of h-BN. With the attenuation factor of the exponential formula, we calculate the inelastic mean free path of electrons and helium ions in the h-BN nanosheets. Our results show that HIM is more sensitive and consistent than FE-SEM for characterizing the number of layers and morphology of 2D materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of surface integrity of grinded gears using Barkhausen noise analysis and x-ray diffraction

The contribution is focused to present results of study grinded gears made of 18CrNiMo7-6 steel used in the wind power plant for support (service) purposes. These gears were case-hardened due to standard hard case and soft core formation. This heat treatment increases wear resistance and fatigue strength of machine parts. During serial production some troubles with surface integrity have occurred. When solving complex problems lots of samples were prepared. For grinding of gears were used different parameters of cutting speed, number of material removal and lots from different subsuppliers. Material characterization was carried out using Barkhausen noise analysis (BNA) device; X-ray diffraction (XRD) measurement of surface residual stresses was done as well. Depth profile of measured characteristics, e.g. magnetoelastic parameter and residual stress was obtained by step by step layers' removing using electrolytic etching. BNA software Viewscan was used to measure magnetizing frequency sweep (MFS) and magnetizing voltage sweep (MVS). Scanning of Magnetoelastic parameter (MP) endwise individual teeth were also carried out with Viewscan. These measurements were done to find problematic surface areas after grinding such as thermal damaged locations. Plots of the hardness and thickness of case-hardened layer on cross sections were measurered as well. Evaluation of structure of subsurface case-hardened layer and core was made on etched metallographic patterns. The aim of performed measurements was to find correlation between conditions of grinding, residual stresses and structural and magnetoelastic parameters. Based on correlation of measured values and technological parameters optimizing the production of gears will be done.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of temperature on performance of {sup 3}He filled neutron proportional counters

Neutron detectors used for cosmic neutron monitoring and various other applications are mounted in hostile environment. It is essential for detectors to sustain extreme climatic conditions, such as extreme temperature and humidity. Effort is made to evaluate the performance of detectors in extreme temperature in terms of pulse height distribution and avalanche formation. Neutron detectors filled with {sup 3}He incorporate an additive gas with quantity optimized for a particular application. Measurements are performed on neutron detectors filled with {sup 3}He and stopping gases Kr and CF{sub 4}. Detector performance for these fill gas combinations in terms of pulse height distribution is evaluated. Gas gain and Diethorn gas constants measured and analyzed for the microscopic effect on pulse formation. Results from these investigations are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic neutron scattering on incoherent systems using efficient resonance spin flip techniques

We have performed numerical ray-tracing Monte-Carlo-simulations of incoherent dynamic neutron scattering experiments. We intend to optimize the efficiency of incoherent measurements depending on the fraction of neutrons scattered without and with spin flip at the sample. In addition to conventional spin echo, we have numerically and experimentally studied oscillating intensity techniques. The results point out the advantages of these different spin echo variants and are an important prerequisite for neutron resonance spin echo instruments like RESEDA (FRM II, Munich), to choose the most efficient technique depending on the scattering vector range and the properties of the sample system under study.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electronic structure and thermoelectric properties of p-type Ag-doped Mg₂Sn and Mg₂Sn{sub 1-x}Si{sub x} (x=0.05, 0.1)

An experimental and theoretical study of p-type Ag-doped Mg₂Sn and Mg₂Sn{sub 1-x}Si{sub x} (x=0.05, 0.1) is presented. Band structure calculations show that behavior of Ag in Mg₂Sn depends on the site it occupies. Based on Bloch spectral functions and density of states calculations, we show that if Ag substitutes for Sn, it is likely to form a resonant level; if it substitutes for Mg, a rigid-band-like behavior is observed. In both cases, the doped system should exhibit p-type conductivity. Experimentally, thermoelectric, thermomagnetic, and galvanomagnetic properties are investigated of p-type Mg₂Sn{sub 1–x}Si{sub x} (x=0, 0.05, 0.1) samples synthesized by a co-melting method in sealed crucibles. Ag effectively dopes the samples p-type, and thermoelectric power factors in excess of 20μW cm⁻¹K⁻² are observed in optimally doped samples. From the measured Seebeck coefficient, Nernst coefficient, and mobility, we find that the combination of acoustic phonon scattering, optical phonon scattering and defect scattering results in an energy-independent scattering rate. No resonant-like increase in thermopower is observed, which correlates well with electronic structure calculations assuming the location of Ag on Mg site.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparative impact analysis of laser radiation on steel grades 1045 and 5140

There are results of experiments with deep engraving steel grades 1045 and 5140. The deep engraving was made by laser system equipped with a pulsed ytterbium fiber laser. The objectives of the work is to evaluate the change in the structure and properties of the material in the laser exposure area. Microsections of materials have been investigated and microhardness was measured for this purpose. The optimal parameters of laser material removal were considered. It is shown that various changes occur in the metal structure, which depends on the composition of the steel. In particular, when processing with identical laser parameters, tempered steel 1045 remelts and its hardness changes, while steel 5140 does not change its structure.

36 MATERIALS SCIENCE↗

Far-field measurements of short-wavelength surface plasmons

We present direct far-field measurements of short-wavelength surface plasmon polaritons (SPP) by conventional optics means. Plasmonic wavelength as short as 231 nm was observed for 532 nm illumination on a Ag−Si{sub 3}N{sub 4} platform, demonstrating the capability to characterize SPPs well below the optical diffraction limit. This is done by scaling a sub-wavelength interferometric pattern to a far-field resolvable periodicity. These subwavelength patterns are obtained by coupling light into counter-propagating SPP waves to create a standing-wave pattern of half the SPP wavelength periodicity. Such patterns are mapped by a scattering slit, tilted at an angle so as to increase the periodicity of the intensity pattern along it to more than the free-space wavelength, making it resolvable by diffraction limited optics. The simplicity of the method as well as its large dynamic range of measurable wavelengths make it an optimal technique to characterize the properties of plasmonic devices and high-index dielectric waveguides, to improve their design accuracy and enhance their functionality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗