Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Operation and performance of the OSSE instrument

The Oriented Scintillation Spectrometer Experiment (OSSE) on the Arthur Holly Compton Gamma Ray Observatory is described. An overview of the operation and control of the instrument is given, together with a discussion of typical observing strategies used with OSSE and basic data types produced by the instrument. Some performance measures for the instrument are presented that were obtained from pre-launch and in-flight data. These include observing statistics, continuum and line sensitivity, and detector effective area and gain stability.

Cameron, R. A.↗

Atomic Resonance Radiation Energetics Investigation as a Diagnostic Method for Non-Equilibrium Hypervelocity Flows

Absorption measurements with a tunable vacuum ultraviolet light source have been proposed as a concentration diagnostic for atomic oxygen, and the viability of this technique is assessed in light of recent measurements. The instrumentation, as well as initial calibration measurements, have been reported previously. We report here additional calibration measurements performed to study the resonance broadening line shape for atomic oxygen. The application of this diagnostic is evaluated by considering the range of suitable test conditions and requirements, and by identifying issues that remain to be addressed.

Meyer, Scott A.↗

Cassini-Huygens Probe Gas Chromatograph Mass Spectrometer (GCMS) Experiment: First Results

The Huygens Probe of the Cassini Huygens Mission entered the atmosphere of the moon Titan on January 14, 2005. The GCMS was part of the instrument complement on the probe to measure in situ the chemical composition of the atmosphere during the probe descent and to support the Aerosol Collector Pyrolyzer (ACP) experiment by serving as detector for the pyrolization products. The GCMS collected data from an altitude of 146 km to ground impact for a time interval of 2hours and 37minutes. The Probe and the GCMS survived the ground impact and collected data for 1hour and 9 minutes on the surface in the near surface environment until signal loss by the orbiter. The major constituents of the lower atmosphere were found to be N2 and CH4. The methane-mixing ratio was found to increase below the turbopause, about 35 km altitude, monotonically toward the surface to levels near saturation. After surface impact a steep increase of the mixing ratio was observed suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. Other constituents were found to be in very low concentrations, below ppm levels. The presence of Argon 40 was confirmed. The results for the other noble gases are still being evaluated. Other hydrocarbons and nitriles were also observed and quantitative evaluation is in progress. Preliminary ratios for the major carbon and nitrogen isotopes were computed from methane and molecular nitrogen measurements. The instrument collected 5634 mass spectra during descent and 2692 spectra on the ground over a range of m/z from 2 to 141. Eight gas chromatograph samples were taken during the descent and two on the ground.

Niemann, H.↗

Radiation Testing of PICA at the Solar Power Tower

Sandia National Laboratory's Solar Power Tower was used to irradiate specimens of Phenolic Impregnated Carbon Ablator (PICA), in order to evaluate whether this thermal protection system material responded differently to potential shock layer radiative heating than to convective heating. Tests were run at 50, 100 and 150 Watts per square centimeter levels of concentrated solar radiation. Experimental results are presented both from spectral measurements on 1- 10 mm thick specimens of PICA, as well as from in-depth temperature measurements on instrumented thicker test specimens. Both spectral measurements and measured in-depth temperature profiles showed that, although it is a porous, low-density material, PICA does not exhibit problematic transparency to the tested high levels of NIR radiation, for all pragmatic cm-to-inch scale thicknesses. PICA acted as a surface absorber to efficiently absorb the incident visible and near infrared incident radiation in the top 2 millimeter layer in the Solar Power Tower tests up to 150 Watts per square centimeter.

White, Susan M.↗

Radiation Testing of PICA at the Solar Power Tower

Sandia National Laboratory's Solar Power Tower was used to irradiate specimens of Phenolic Impregnated Carbon Ablator (PICA), in order to evaluate whether this thermal protection system material responded differently to potential shock layer radiative heating than to convective heating. Tests were run at 50, 100 and 150 Watts per square centimeter levels of concentrated solar radiation. Experimental results are presented both from spectral measurements on 1- 10 mm thick specimens of PICA, as well as from in-depth temperature measurements on instrumented thicker test specimens. Both spectral measurements and measured in-depth temperature profiles showed that, although it is a porous, low-density material, PICA does not exhibit problematic transparency to the tested high levels of NIR radiation, for all pragmatic cm-to-inch scale thicknesses. PICA acted as a surface absorber to efficiently absorb the incident visible and near infrared incident radiation in the top 2 millimeter layer in the Solar Power Tower tests up to 150 Watts per square centimeter.

White, Susan↗

Measuring Luminescence Lifetime With Help of a DSP

An instrument for measuring the lifetime of luminescence (fluorescence or phosphorescence) includes a digital signal processor (DSP) as the primary means of control, generation of excitation signals, and analysis of response signals. The DSP hardware in the present instrument makes it possible to switch among a variety of operating modes by making changes in software only.

Danielson, J. D. S.↗

A Comparison of Measurements from ATMOS and Instruments Aboard the ER-2 Aircraft: Tracers of Atmospheric Transport and Halogenated Gases

We compare volume mixing ratio profiles of N2O, O3, NO(y), H2O, CH4, and CO in the mid-latitude lower stratosphere measured by the ATMOS Fourier transform spectrometer on the ATLAS-3 Space Shuttle Mission with in situ measurements acquired from the NASA ER-2 aircraft during Nov 1994. ATMOS and ER-2 observations of (N2O) show good agreement, as do measured correlations of (O3), (NO(y)), (H2O), and (CH4) with (N2O). Thus a consistent measure of the hydrogen (H2O, CH4) content of the lower stratosphere is provided by the two platforms. The similarity of (NO(y)) determined by detection of individual species by ATMOS and the total (NOy) measurement on the ER-2 provides strong corroboration for the accuracy of both techniques. A 25% discrepancy in lower stratospheric (CO) observed by ATMOS and the ER-2 remains unexplained. Otherwise, the agreement for measurements of long-lived tracers demonstrates the ability to combine ATMOS data with in situ observations for quantifying atmospheric transport.

Chang, A. Y.↗

Investigation of Next-Generation Earth Radiation Budget Radiometry

The current effort addresses two issues important to the research conducted by the Thermal Radiation Group at Virginia Tech. The first research topic involves the development of a method which can properly model the diffraction of radiation as it enters an instrument aperture. The second topic involves the study of a potential next-generation space-borne radiometric instrument concept. Presented are multiple modeling efforts to describe the diffraction of monochromatic radiant energy passing through an aperture for use in the Monte-Carlo ray-trace environment. Described in detail is a deterministic model based upon Heisenberg's uncertainty principle and the particle theory of light. This method is applicable to either Fraunhofer or Fresnel diffraction situations, but is incapable of predicting the secondary fringes in a diffraction pattern. Also presented is a second diffraction model, based on the Huygens-Fresnel principle with a correcting obliquity factor. This model is useful for predicting Fraunhofer diffraction, and can predict the secondary fringes because it keeps track of phase. NASA is planning for the next-generation of instruments to follow CERES (Clouds and the Earth's Radiant Energy System), an instrument which measures components of the Earth's radiant energy budget in three spectral bands. A potential next-generation concept involves modification of the current CERES instrument to measure in a larger number of wavelength bands. This increased spectral partitioning would be achieved by the addition of filters and detectors to the current CERES geometry. The capacity of the CERES telescope to serve for this purpose is addressed in this thesis.

Coffey, Katherine L.↗

Soot Particle Studies - Instrument Inter-Comparison – Project Overview

An inter-comparison study of instruments designed to measure the microphysical and optical properties of soot particles was completed. The following mass-based instruments were tested: Couette Centrifugal Particle Mass Analyzer (CPMA), Time-of-Flight Aerosol Mass Spectrometer - Scanning Mobility Particle Sizer (AMS-SMPS), Single Particle Soot Photometer (SP2), Soot Particle-Aerosol Mass Spectrometer (SP-AMS) and Photoelectric Aerosol Sensor (PAS2000CE). Optical instruments measured absorption (photoacoustic, interferometric, and filter-based), scattering (in situ), and extinction (light attenuation within an optical cavity). The study covered an experimental matrix consisting of 318 runs that systematically tested the performance of instruments across a range of parameters including: fuel equivalence ratio (1.8 {le} {phi} {le} 5), particle shape (mass-mobility exponent (D{sub f m}), 2.0 {le} D{sub f m} {le} 3.0), particle mobility size (30 {le} d{sub m} {le} 300 nm), black carbon mass (0.07 {le} m{sub BC} {le} 4.2 fg) and particle chemical composition. In selected runs, particles were coated with sulfuric acid or dioctyl sebacate (DOS) (0.5 {le} {Delta}r{sub ve} {le} 201 nm) where {Delta}r{sub ve} is the change in the volume equivalent radius due to the coating material. The effect of non-absorbing coatings on instrument response was determined. Changes in the morphology of fractal soot particles were monitored during coating and denuding processes and the effect of particle shape on instrument response was determined. The combination of optical and mass based measurements was used to determine the mass specific absorption coefficient for denuded soot particles. The single scattering albedo of the particles was also measured. An overview of the experiments and sample results are presented.

54 ENVIRONMENTAL SCIENCES↗

Plasma Escape from Unmagnetized Bodies

A considerable fraction of atmospheric loss at Venus and Titan is in the form of plasma escape. This is due in part to the fact that the ionospheres of these unmagnetized bodies interact directly with the high speed plasmas flowing around them. The similarities of the interactions help reinforce interpretations of measurements made at each body, especially when instruments and measurement sites differ. For example, it is well established through this method that ions born in the exospheres above the ionopauses are picked up and carried away by the solar wind at Venus and the rotating plasma in Saturn's magnetosphere. On the other hand, it is more difficult to relate the observations associated with escape of cooler ionospheric plasma down the ionotails of each body. A clear example of ionospheric plasma escaping Titan was observed as it flowed down its ionotail (1). Measurements at Venus have not as yet clearly distinguished between ionospheric and pickup ion escape in the ionotail; however, cold ions detected in the distant wake at 1 AU by the CELIAS/CTOF instrument on SOHO have been interpreted as ionospheric in origin (2). An algorithm to determine ionospheric flow from Pioneer Venus aeronomical measurements is used to show that escape of cold ionospheric plasma is likely to occur. These results along with plasma flow measurements made in the ionotail of Venus are combined and compared to the corresponding flow at Titan.

Hartle, R. E.↗

The Global Precipitation Measurement (GPM) Microwave Imager (GMI): Instrument Overview and Early On-Orbit Performance

The Global Precipitation Measurement (GPM) mission is an international satellite mission that uses measurements from an advanced radar/radiometer system on a core observatory as reference standards to unify and advance precipitation estimates made by a constellation of research and operational microwave sensors. The GPM core observatory was launched on February 27, 2014 at 18:37 UT in a 65◦ inclination nonsun-synchronous orbit. GPM focuses on precipitation as a key component of the Earth's water and energy cycle, and has the capability to provide near-real-time observations for tracking severe weather events, monitoring freshwater resources, and other societal applications. The GPM microwave imager (GMI) on the core observatory provides the direct link to the constellation radiometer sensors, which fly mainly in polar orbits. The GMI sensitivity, accuracy, and stability play a crucial role in unifying the measurements from the GPM constellation of satellites. The instrument has exhibited highly stable operations through the duration of the calibration/validation period. This paper provides an overview of the GMI instrument and a report of early on-orbit commissioning activities. It discusses the on-orbit radiometric sensitivity, absolute calibration accuracy, and stability for each radiometric channel. Index Terms-Calibration accuracy, passive microwave remote sensing, radiometric sensitivity.

GPM↗

Dosimetric Quantities for Computed Tomography Examinations of Paediatric Patients on the Thoracic and Abdominal Regions

Computed Tomography (CT) is a high dose X ray imaging procedure and its use has rapidly increased in the last two decades fueled by the development of helical CT. The aim of this study is to present values of the dosimetric quantities for CT paediatric examinations of thoracic and abdominal regions. The protocols studied were those of chest, lung-mediastine, chest-abdomen, pulmonary high resolution and mediastine-abdomen, which are the more common examinations performed at ''Hospital Infantil de Mexico Federico Gomez'' in the thoracic-abdominal region. The measurements were performed on a Siemens SOMATOM Sensation 16 CT Scanner and the equipment used was a CT pencil ionization chamber, connected to an electrometer. This system was calibrated for RQT9 CT beam quality. A PMMA head phantom with diameter of 16 cm and length of 15 cm was also used. The dosimetric quantities measured were the weighted air kerma index (C{sub w}), the volumetric dose index (C{sub vol}) and the CT air kerma-length product. It was found that the pulmonary high resolution examination presented the highest values for the C{sub w}(31.1 mGy) and C{sub vol}(11.1 mGy). The examination with the lowest values of these two quantities was the chest-abdomen protocol with 10.5 mGy for C{sub w} and 5.5 mGy for C{sub vol}. However, this protocol presented the highest value for P{sub KL,CT}(282.2 mGy cm) when considering the average clinical length of the examinations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electrooptic phase modulation gas correlation spectroscopy - A laboratory demonstration

A new gas-correlation spectroscopy technique is described which uses electrooptic phase modulation (EOPM) of atmospheric emission spectra together with a reference cell to selectively detect radiatively active gases. Laboratory results demonstrate that the EOPM gas-correlation technique is a sensitive approach to species abundance measurements, and support the feasibility of an instrument for measurement of winds in the stratosphere and mesosphere using an EOPM. Through the measurement of wind-induced Doppler shifts in the spectra of atmospheric species, this instrument offers a means of monitoring the wind field in the 20-100 km altitude range from a satellite.

Rider, D. M.↗

In situ ozone instrumentation for 10-Hz measurements - Development and evaluation

The development of the fast-response ozone detector for the Electra aircraft is described. The selection of a technique to meet the design goal of 10-Hz detection is examined in terms of detection principles, instrument sampling parameters, signal conditioning, and aircraft and sampling environment. An instrument which employs a NO technique for detection of ozone with a reaction chamber volume of 16 cu cm, a pressure of 60 torr, and a sample flow of 1000 standard cu cm/min was developed. Laboratory and flight testings of the detector were conducted in order to evaluate its performance. The data reveal that the fast-response ozone detector is highly reliable with a response of 0.1 sec to 90 percent of reading, has a lower detection limit of 1 ppbv, and an S/N of 20 at 20 ppbv ozone.

Gregory, G. L.↗

Turbulence measurements using tethered balloon instrumentation during FIRE 1987

As part of the surface-based observations conducted on San Nicolas Island, the U.K. Meteorological Office operated a set of turbulence probes attached to a balloon tether cable. Typically six probes were used, each capable of measuring momentum, heat, and humidity fluxes. Two probes were fitted with net radiometers, one positioned above cloud and the other below; a third probe carried a Lyman-alpha hygrometer fitted with a pre-heater for the measurement of total water content. Some preliminary results are presented from the 14th July describing the variation in structure of the cloudy boundary layer during the daytime. This day was characterized by a complete cloud cover, an inversion height of approximately 600 m. and north-westerly winds of approximately 6 m.s(-1). As an illustration the equivalent potential temperature derived from a profile ascent made between approximately 0830 and 0930 (PDT) is shown. The data has been smoothed to a height resolution of about 4 metres. At this time the cloud base was approximately 200 m. and very light drizzle was reaching the surface. The vertical velocity variance and potential temperature flux for two periods are shown; the first (shown by full lines) immediately follows the profile and the second (shown by dashed lines) is central around 1400 (PDT). The data have been normalized by their maximum values in the first period. Cloud base has now risen to approximately 300 m. There is a marked variation during the morning, particularly in sigma w. The net radiative flux above cloud top has by now reached its maximum value.

Hignett, Phillip↗

Performance Assessment of Portable Optical Particle Spectrometer (POPS)

Accurate representation of atmospheric aerosol properties is a long-standing problem in atmospheric research. Modern pilotless aerial systems provide a new platform for atmospheric in situ measurement. However, small airborne platforms require miniaturized instrumentation due to apparent size, power, and weight limitations. A Portable Optical Particle Spectrometer (POPS) is an emerged instrument to measure ambient aerosol size distribution with high time and size resolution, designed for deployment on a small unmanned aerial system (UAS) or tethered balloon system (TBS) platforms. This study evaluates the performance of a POPS with an upgraded laser heater and additional temperature sensors in the aerosol pathway. POPS maintains its performance under different environmental conditions as long as the laser temperature remains above 25 °C and the aerosol flow temperature inside the optical chamber is 15 °C higher than the ambient temperature. The comparison between POPS and an Ultra-High Sensitivity Aerosol Spectrometer (UHSAS) suggests that the coincidence error is less than 25% when the number concentration is less than 4000 cm –3 . The size distributions measured by both of them remained unaffected up to 15,000 cm –3 . While both instruments’ sizing accuracy is affected by the aerosol chemical composition and morphology, the influence is more profound on the POPS.

47 OTHER INSTRUMENTATION↗

Simultaneous Iron and Nickel Isotopic Analyses of Presolar Silicon Carbide Grains.

Aside from recording stellar nucleosynthesis, a few elements in presolar grains can also provide insights into the galactic chemical evolution (GCE) of nuclides. We have studied the carbon, silicon, iron, and nickel isotopic compositions of presolar silicon carbide (SiC) grains from asymptotic giant branch (AGB) stars to better understand GCE. Since only the neutron-rich nuclides in these grains have been heavily influenced by the parent star, the neutron-poor nuclides serve as GCE proxies. Using CHILI, a new resonance ionizationmass spectrometry (RIMS) instrument, we measured 74 presolar SiC grains for all iron and nickel isotopes. With the CHARISMA instrument, 13 presolar SiC grains were analyzed for iron isotopes. All grains were also measured by NanoSIMS for their carbon and silicon isotopic compositions. A comparison of the measured neutron-rich isotopes with models for AGB star nucleosynthesis shows that our measurements are consistent with AGB star predictions for low-mass stars between half-solar and solar metallicity. Furthermore, our measurements give an indication on the Ne-22(alpha, n)Mg-25 reaction rate. In terms of GCE, we find that the GCE-dominated iron and nickel isotope ratios, Fe-54/Fe-56 and Ni-60/Ni-58, correlate with their GCE-dominated counterpart in silicon, Si-29/Si-28. The measured GCE trends include the Solar System composition, showing that the Solar System is not a special case. However, as seen in silicon and titanium, many presolar SiC grains are more evolved for iron and nickel than the Solar System. This confirms prior findings and agrees with observations of large stellar samples that a simple age-metallicity relationship for GCE cannot explain the composition of the solar neighborhood. (C) 2017 Elsevier Ltd. All rights reserved.

galactic chemical evolution↗