Search NASA⌕ Search

SEARCH · Search NASA

Results for “Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Comparison of Some Representative Density Functional Theory and Wave Function Theory Methods for the Studies of Amino Acids

Energies of different conformers of 22 amino acid molecules and their protonated and deprotonated species were calculated by some density functional theory (DFT; SVWN, B3LYP, B3PW91, MPWB1K, BHandHLYP) and wave function theory (WFT; HF, MP2) methods with the 6-31111G(d,p) basis set to obtain the relative conformer energies, vertical electron detachment energies, deprotonation energies, and proton affinities. Taking the CCSD/6-31111G(d,p) results as the references, the performances of the tested DFT and WFT methods for amino acids with various intramolecular hydrogen bonds were determined. The BHandHLYP method was the best overall performer among the tested DFT methods, and its accuracy was even better than that of the more expensive MP2 method. The computational dependencies of the five DFT methods and the HF and MP2 methods on the basis sets were further examined with the 6-31G(d,p), 6-31111G(d,p), aug-cc-pVDZ, 6-31111G(2df,p), and aug-cc-pVTZ basis sets. The differences between the small and large basis set results have decreased quickly for the hybrid generalized gradient approximation (GGA) methods. The basis set convergence of the MP2 results has been, however, very slow. Considering both the cost and the accuracy, the BHandHLYP functional with the 6-31111G(d,p) basis set is the best choice for the amino acid systems that are rich in hydrogen bonds.

08 HYDROGEN↗

A comparison of preconditioned Krylov subspace methods for large‐scale nonsymmetric linear systems

Summary Preconditioned Krylov subspace (KSP) methods are widely used for solving large‐scale sparse linear systems arising from numerical solutions of partial differential equations (PDEs). These linear systems are often nonsymmetric due to the nature of the PDEs, boundary or jump conditions, or discretization methods. While implementations of preconditioned KSP methods are usually readily available, it is unclear to users which methods are the best for different classes of problems. In this work, we present a comparison of some KSP methods, including GMRES, TFQMR, BiCGSTAB, and QMRCGSTAB, coupled with three classes of preconditioners, namely, Gauss–Seidel, incomplete LU factorization (including ILUT, ILUTP, and multilevel ILU), and algebraic multigrid (including BoomerAMG and ML). Theoretically, we compare the mathematical formulations and operation counts of these methods. Empirically, we compare the convergence and serial performance for a range of benchmark problems from numerical PDEs in two and three dimensions with up to millions of unknowns and also assess the asymptotic complexity of the methods as the number of unknowns increases. Our results show that GMRES tends to deliver better performance when coupled with an effective multigrid preconditioner, but it is less competitive with an ineffective preconditioner due to restarts. BoomerAMG with a proper choice of coarsening and interpolation techniques typically converges faster than ML, but both may fail for ill‐conditioned or saddle‐point problems, whereas multilevel ILU tends to succeed. We also show that right preconditioning is more desirable. This study helps establish some practical guidelines for choosing preconditioned KSP methods and motivates the development of more effective preconditioners.

Ghai, Aditi↗

Physicochemical and Performance Characterization of Six Commercial Organic Solvent Nanofiltration Membranes

This work introduces a novel, gradient-free metamaterial design method based on Gaussian process regression to represent the density field of a unit cell. The dimension of the design space is determined by the covariance matrix dimension in the Gaussian process regression. We propose compressing this matrix using an autoencoder, enabling the decoder to generate the density field and effectively reduce the originally large design space to a lower-dimensional subspace. In this compressed space, we employ an active learning method, Bayesian Adaptive Direct Search (BADS), for efficient exploration of the design space. We demonstrate that for simple 2D designs aimed at maximizing unit cell stiffness, our method yields results comparable to those of standard topology optimization. Furthermore, we extend our approach to various mechanical problems, from linear elasticity to hyperelastic large deformation and elasto-plasticity under finite deformation, to 3D metamaterial design. This illustrates the method’s versatility and effectiveness across a range of applications.

Wu, Haoran↗

Fusion Imaging to Guide Thoracic Endovascular Aortic Repair (TEVAR): A Randomized Comparison of Two Methods, 2D/3D Versus 3D/3D Image Fusion

Purpose: To compare the accuracy of two-dimensional (2D) versus three-dimensional (3D) image fusion for thoracic endovascular aortic repair (TEVAR) image guidance. Materials and Methods: Between December 2016 and March 2018, all eligible patients who underwent TEVAR were prospectively included in a single-center study. Image fusion methods (2D/3D or 3D/3D) were randomly assigned to guide each TEVAR and compared in terms of accuracy, dose area product (DAP), volume of contrast medium injected, fluoroscopy time and procedure time. Results: Thirty-two patients were prospectively included; 18 underwent 2D/3D and 14 underwent 3D/3D TEVAR. The 3D/3D method allowed more accurate positioning of the aortic mask on top of the fluoroscopic images (proximal landing zone error vector: 1.7 ± 3.3 mm) than was achieved by the 2D/3D method (6.1 ± 6.1 mm; p = 0.03). The 3D/3D image fusion method was associated with significantly lower DAP than the 2D/3D method (50.5 ± 30.1 Gy cm{sup 2} for 3D/3D vs. 99.5 ± 79.1 Gy cm{sup 2} for 2D/3D; p = 0.03). The volume of contrast medium injected was significantly lower for the 3D/3D method than for the 2D/3D method (50.6 ± 22.9 ml vs. 98.4 ± 47.9 ml; p = 0.002). Conclusion: Higher image fusion accuracy and lower contrast volume and irradiation dose were observed for 3D/3D image fusion than for 2D/3D during TEVAR. Level of Evidence: II, Randomized trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structure-aware methods for expensive derivative-free nonsmooth composite optimization

We present new methods for solving a broad class of bound-constrained nonsmooth composite minimization problems. These methods are specially designed for objectives that are some known mapping of outputs from a computationally expensive function. We provide accompanying implementations of these methods: in particular, a novel manifold sampling algorithm (MS-P) with subproblems that are in a sense primal versions of the dual problems solved by previous manifold sampling methods and a method (GOOMBAH) that employs more difficult optimization subproblems. For these two methods, we provide rigorous convergence analysis and guarantees. We demonstrate extensive testing of these methods. Open-source implementations of the methods developed in this manuscript can be found at https://github.com/POptUS/ IBCDFO/.

97 MATHEMATICS AND COMPUTING↗

Comparison and validation of the QuEChERSER mega-method for determination of per- and polyfluoroalkyl substances in foods by liquid chromatography with high-resolution and triple quadrupole mass spectrometry

Instances of food contamination with per- and polyfluoroalkyl substances (PFAS) continue to occur globally, but sample preparation and analytical methods are quite limited and often monitor for a small percentage of known PFAS. This study aimed to evaluate, validate, and compare performance of two instruments with the recently developed “quick, easy, cheap, effective, rugged, safe, efficient, and robust” (QuEChERSER) sample preparation mega-method – a method developed to monitor chemicals over a broad range of physicochemical properties. Initial evaluation of the QuEChERSER mega-method for determination of PFAS in food demonstrated recoveries, matrix interferences, and co-extractive removal comparable to (or better than) US Food and Drug Administration (FDA) and USDA Food Safety and Inspection Service (FSIS) methods. Subsequent validation of QuEChERSER in beef, catfish, chicken, pork, liquid eggs, and powdered eggs on a high-resolution mass spectrometer achieved acceptable recoveries (70–120%) and precision (RSDs ≤20%) for all 33 target analytes at the 1 and 5 ng g –1 levels and 67–88% of analytes at the 0.1 ng g –1 level, depending on the matrix. Additional validation was performed by tandem mass spectrometry on a triple quadrupole instrument. This approach provided no non-detects and better recoveries at the 0.1 ng g –1 level than the HRMS method but exhibited more variability at 1 and 5 ng g –1 spiking levels. Analysis of NIST SRMs 1946 and 1947 gave accuracies of 70–117%. Furthermore, these results demonstrate the capability of combining PFAS analysis with a mega-method previously validated for 350 analytes, while collecting non-target data for future retrospective analysis of emerging alternatives with a high-resolution mass spectrometry method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Newton trust-region methods with primary variable switching for simulating high temperature multiphase porous media flow

Coupling multiphase flow with energy transport due to high temperature heat sources introduces significant new challenges since boiling and condensation processes can lead to dry-out conditions with subsequent re-wetting. The transition between two-phase and single-phase behavior can require changes to the primary dependent variables adding discontinuities as well as extending constitutive nonlinear relations to extreme physical conditions. Practical simulations of large-scale engineered domains lead to Jacobian systems with a very large number of unknowns that must be solved efficiently using iterative methods in parallel on high-performance computers. Performance assessment of potential nuclear repositories, carbon sequestration sites and geothermal reservoirs can require numerous Monte-Carlo simulations to explore uncertainty in material properties, boundary conditions, and failure scenarios. Due to the numerical challenges, standard NR iteration may not converge over the range of required simulations and require more sophisticated optimization method like trust-region. In this study, we use the open-source simulator PFLOTRAN for the important practical problem of the safety assessment of future nuclear waste repositories in the U.S. DOE geologic disposal safety assessment Framework. The simulator applies the PETSc parallel framework and a backward Euler, finite volume discretization. We demonstrate failure of the conventional NR method and the success of trust-region modifications to Newton’s method for a series of test problems of increasing complexity. Trust-region methods essentially modify the Newton step size and direction under some circumstances where the standard NR iteration can cause the solution to diverge or oscillate. Furthermore, we show how the Newton Trust-Region method can be adapted for Primary Variable Switching (PVS) when the multiphase state changes due to boiling or condensation. The simulations with high-temperature heat sources which led to extreme nonlinear processes with many state changes in the domain did not converge with NR, but they do complete successfully with the trust-region methods modified for PVS. This implementation effectively decreased weeks of simulation time needing manual adjustments to complete a simulation down to a day. Finally, we show the strong scalability of the methods on a single node and multiple nodes in an HPC cluster.

54 ENVIRONMENTAL SCIENCES↗

Clumping index estimation with 30°-tilted cameras in row crops: Evaluation of methods and segment size effects

The clumping index (CI) quantifies the spatial distribution of foliage elements and is essential for accurately estimating the plant area index (PAI), canopy radiative transfer, and photosynthesis. Traditionally, the finite-length averaging method (LX), the gap size distribution method (CC), and a combined approach of CC and LX (CLX) have been applied to instruments like TRAC and digital hemispherical photography to estimate CI. However, a comprehensive evaluation of these methods in row crops remains limited, especially regarding the influence of segment size on CI. Meanwhile, digital cameras offer a cost-effective and user-friendly solution for canopy measurements in row crops, yet their application in this context remains underexplored. In this study, we employed a new approach using a 30°-tilted digital camera to estimate CI in corn and soybean fields, applying the LX, CC, and CLX methods. We systematically assessed the performance of these three methods by combining field measurements in real-world fields with simulations using the LESS 3D radiative transfer model. Our results showed that CLX applied to the whole image and 45° segment offered accurate estimation of CI (bias within ±0.1, RMSE < 0.2) and PAI (bias within ±0.4, RMSE < 1) in real-world fields and LESS simulations. The accuracy of the LX method was highly sensitive to segment size, with the best performance observed at the 15° segment (PAI bias within ±0.4). In contrast, the CC method remained stable across different segment sizes, and its performance was generally comparable to that of LX, except at the 15° segment. Across view zenith angles, CI derived from CC generally showed a continuous increase, while those from LX and CLX followed a rising trend at small zenith angles but began to decline at 68°, likely due to an increasing proportion of no-gap segments. Seasonally, LX tended to show decreasing CI during early growth stages but increased as the canopy matured, whereas CC and CLX showed gradually increasing CI before plateauing at peak PAI. The 30°-tilted camera effectively captured CI variations across different angles and growth stages, making it a practical and robust instrument for row crop canopy structure analysis. Furthermore, applying these CI methods to digital cameras offers a low-cost and accessible CI estimation alternative, improving canopy structure monitoring accuracy in row crops.

30°-tilted camera↗

Verification and validation of the maximum entropy method for reconstructing neutron flux, with MCNP5, Attila-7.1.0 and the GODIVA experiment

Verification and validation of reconstructed neutron flux based on the maximum entropy method is presented in this paper. The verification is carried out by comparing the neutron flux spectrum from the maximum entropy method with Monte Carlo N Particle 5 version 1.40 (MCNP5) and Attila-7.1.0-beta (Attila). A spherical 100% 235U critical assembly is modeled as the test case to compare the three methods. The verification error range for the maximum entropy method is 15–21% where MCNP5 is taken to be the comparison standard. Attila relative error for the critical assembly is 20–35%. Validation is accomplished by comparing a neutron flux spectrum that is back calculated from foil activation measurements performed in the GODIVA experiment (GODIVA). The error range of the reconstructed flux compared to GODIVA is 0–10%. The error range of the neutron flux spectrum from MCNP5 compared to GODIVA is 0–20% and the Attila error range compared to the GODIVA is 0–35%. The maximum entropy method is shown to be a fast reliable method, compared to either Monte Carlo methods (MCNP5) or 30 multienergy group methods (Attila) and with respect to the GODIVA experiment.

99 GENERAL AND MISCELLANEOUS↗

Statistical Methods Applied to Gamma-ray Spectroscopy Algorithms in Nuclear Security Missions

In a wide range of nuclear security missions, gamma-ray spectroscopy is a critical research and development priority. One particularly relevant challenge is the interdiction of special nuclear material for which gamma-ray spectroscopy supports the goals of detecting and identifying gamma-ray sources. This manuscript examines the existing set of spectroscopy methods, attempts to categorize them by the statistical methods on which they rely, and identifies methods that have yet to be considered. Our examination shows that current methods effectively estimate the effect of counting uncertainty but in many cases do not address larger sources of decision uncertainty—ones that are significantly more complex. We thus explore the premise that significantly improving algorithm performance requires greater coupling between the problem physics that drives data acquisition and statistical methods that analyze such data. Untapped statistical methods, such as Bayes Modeling Averaging and hierarchical and empirical Bayes methods have the potential to reduce decision uncertainty by more rigorously and comprehensively incorporating all sources of uncertainty. We expect that application of such methods will demonstrate progress in meeting the needs of nuclear security missions by improving on the existing numerical infrastructure for which these analyses have not been conducted.

detection algorithm.↗

Feasibility of using thermal response methods for nonintrusive compressed air flow measurement

Robust, low-cost nonintrusive flow meters are of interest in many industries. Particularly, a reliable nonintrusive flow measurement for the diagnosis of air leaks in compressed air systems is desirable. Measurement of the air flow due to leaks in the system ensures an accurate estimation of potential cost and energy savings. This study evaluates a novel method of using thermal responses to nonintrusively measure leakage rates in compressed air lines. The method uses heat and the resulting thermal response to calculate the flow rate inside the compressed air line. Compared to the current methods for flow measurement, this method can simplify flow measurement while decreasing the sensitivity to errors when measuring flow rates. In this study, the methodology of the proposed method is explained along with the potential advantages to the design. Two approaches are evaluated: a dynamic step response and sinusoidal frequency response. Simulated tests evaluate the feasibility of the proposed methods, followed by experiments that validate the simulation results. A clear correlation between the thermal step response and the flow rate indicate viability of the proposed method in simulation. Experimental results yielded similar results, confirming the validity of the proposed method. The results of a field test in an industrial environment demonstrate the capability of the approach to other flow rate measurement techniques.

42 ENGINEERING↗

Development and Clinical Evaluation of a Three-Dimensional Cone-Beam Computed Tomography Estimation Method Using a Deformation Field Map

Purpose: To develop a three-dimensional (3D) cone-beam computed tomography (CBCT) estimation method using a deformation field map, and to evaluate and optimize the efficiency and accuracy of the method for use in the clinical setting. Methods and Materials: We propose a method to estimate patient CBCT images using prior information and a deformation model. Patients' previous CBCT data are used as the prior information, and the new CBCT volume to be estimated is considered as a deformation of the prior image volume. The deformation field map is solved by minimizing deformation energy and maintaining new projection data fidelity using a nonlinear conjugate gradient method. This method was implemented in 3D form using hardware acceleration and multi-resolution scheme, and it was evaluated for different scan angles, projection numbers, and scan directions using liver, lung, and prostate cancer patient data. The accuracy of the estimation was evaluated by comparing the organ volume difference and the similarity between estimated CBCT and the CBCT reconstructed from fully sampled projections. Results: Results showed that scan direction and number of projections do not have significant effects on the CBCT estimation accuracy. The total scan angle is the dominant factor affecting the accuracy of the CBCT estimation algorithm. Larger scan angles yield better estimation accuracy than smaller scan angles. Lung cancer patient data showed that the estimation error of the 3D lung tumor volume was reduced from 13.3% to 4.3% when the scan angle was increased from 60 Degree-Sign to 360 Degree-Sign using 57 projections. Conclusions: The proposed estimation method is applicable for 3D DTS, 3D CBCT, four-dimensional CBCT, and four-dimensional DTS image estimation. This method has the potential for significantly reducing the imaging dose and improving the image quality by removing the organ distortion artifacts and streak artifacts shown in images reconstructed by the conventional Feldkamp-Davis-Kress (FDK) algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone Beam Computed Tomography Number Errors and Consequences for Radiotherapy Planning: An Investigation of Correction Methods

Purpose: The potential of keV cone beam computed tomography (CBCT) for guiding adaptive replanning is well-known. There are impediments to this, one being CBCT number accuracy. The purpose of this study was to investigate CBCT number correction methods and the affect of residual inaccuracies on dose deposition. Four different correction strategies were applied to the same patient data to compare performance and the sophistication of correction-method needed for acceptable dose errors. Methods and Materials: Planning CT and CBCT reconstructions were used for 12 patients (6 brain, 3 prostate, and 3 bladder cancer patients). All patients were treated using Elekta linear accelerators and XVI imaging systems. Two of the CBCT number correction methods investigated were based on an algorithm previously proposed by the authors but only previously applied to phantoms. Two further methods, based on an approach previously suggested in the research literature, were also examined. Dose calculations were performed using scans of a 'worst' subset of patients using the Pinnacle{sup 3} version 9.0 treatment planning system and the patients' clinical plans. Results: All mean errors in CBCT number were <50 HU, and all correction methods performed well or adequately in dose calculations. The worst single dose discrepancy identified for any of the examined methods or patients was 3.0%. Mean errors in the doses to treatment volumes or organs at risk were negatively correlated with the mean error in CT number. That is, a mean CT number that was too large, averaged over the entire CBCT volume, implied an underdosing in a volume-of-interest and vice versa. Conclusions: Results suggest that (1) the correction of CBCT numbers to within a mean error of 50 HU in the scan volume provides acceptable discrepancies in dose (<3%) and (2) this is achievable with even quite unsophisticated correction methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simple Method to Estimate Mean Heart Dose From Hodgkin Lymphoma Radiation Therapy According to Simulation X-Rays

Purpose: To describe a new method to estimate the mean heart dose for Hodgkin lymphoma patients treated several decades ago, using delineation of the heart on radiation therapy simulation X-rays. Mean heart dose is an important predictor for late cardiovascular complications after Hodgkin lymphoma (HL) treatment. For patients treated before the era of computed tomography (CT)-based radiotherapy planning, retrospective estimation of radiation dose to the heart can be labor intensive. Methods and Materials: Patients for whom cardiac radiation doses had previously been estimated by reconstruction of individual treatments on representative CT data sets were selected at random from a case–control study of 5-year Hodgkin lymphoma survivors (n=289). For 42 patients, cardiac contours were outlined on each patient's simulation X-ray by 4 different raters, and the mean heart dose was estimated as the percentage of the cardiac contour within the radiation field multiplied by the prescribed mediastinal dose and divided by a correction factor obtained by comparison with individual CT-based dosimetry. Results: According to the simulation X-ray method, the medians of the mean heart doses obtained from the cardiac contours outlined by the 4 raters were 30 Gy, 30 Gy, 31 Gy, and 31 Gy, respectively, following prescribed mediastinal doses of 25-42 Gy. The absolute-agreement intraclass correlation coefficient was 0.93 (95% confidence interval 0.85-0.97), indicating excellent agreement. Mean heart dose was 30.4 Gy with the simulation X-ray method, versus 30.2 Gy with the representative CT-based dosimetry, and the between-method absolute-agreement intraclass correlation coefficient was 0.87 (95% confidence interval 0.80-0.95), indicating good agreement between the two methods. Conclusion: Estimating mean heart dose from radiation therapy simulation X-rays is reproducible and fast, takes individual anatomy into account, and yields results comparable to the labor-intensive representative CT-based method. This simpler method may produce a meaningful measure of mean heart dose for use in studies of late cardiac complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A dynamically bi-orthogonal method for time-dependent stochastic partial differential equations II: Adaptivity and generalizations

This is part II of our paper in which we propose and develop a dynamically bi-orthogonal method (DyBO) to study a class of time-dependent stochastic partial differential equations (SPDEs) whose solutions enjoy a low-dimensional structure. In part I of our paper [9], we derived the DyBO formulation and proposed numerical algorithms based on this formulation. Some important theoretical results regarding consistency and bi-orthogonality preservation were also established in the first part along with a range of numerical examples to illustrate the effectiveness of the DyBO method. In this paper, we focus on the computational complexity analysis and develop an effective adaptivity strategy to add or remove modes dynamically. Our complexity analysis shows that the ratio of computational complexities between the DyBO method and a generalized polynomial chaos method (gPC) is roughly of order O((m/N{sub p}){sup 3}) for a quadratic nonlinear SPDE, where m is the number of mode pairs used in the DyBO method and N{sub p} is the number of elements in the polynomial basis in gPC. The effective dimensions of the stochastic solutions have been found to be small in many applications, so we can expect m is much smaller than N{sub p} and computational savings of our DyBO method against gPC are dramatic. The adaptive strategy plays an essential role for the DyBO method to be effective in solving some challenging problems. Another important contribution of this paper is the generalization of the DyBO formulation for a system of time-dependent SPDEs. Several numerical examples are provided to demonstrate the effectiveness of our method, including the Navier–Stokes equations and the Boussinesq approximation with Brownian forcing.

97 MATHEMATICS AND COMPUTING↗

A comparison of acceleration methods for solving the neutron transport k-eigenvalue problem

Over the past several years a number of papers have been written describing modern techniques for numerically computing the dominant eigenvalue of the neutron transport criticality problem. These methods fall into two distinct categories. The first category of methods rewrite the multi-group k-eigenvalue problem as a nonlinear system of equations and solve the resulting system using either a Jacobian-Free Newton–Krylov (JFNK) method or Nonlinear Krylov Acceleration (NKA), a variant of Anderson Acceleration. These methods are generally successful in significantly reducing the number of transport sweeps required to compute the dominant eigenvalue. The second category of methods utilize Moment-Based Acceleration (or High-Order/Low-Order (HOLO) Acceleration). These methods solve a sequence of modified diffusion eigenvalue problems whose solutions converge to the solution of the original transport eigenvalue problem. This second class of methods is, in our experience, always superior to the first, as most of the computational work is eliminated by the acceleration from the LO diffusion system. In this paper, we review each of these methods. Our computational results support our claim that the choice of which nonlinear solver to use, JFNK or NKA, should be secondary. The primary computational savings result from the implementation of a HOLO algorithm. We display computational results for a series of challenging multi-dimensional test problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shock waves simulated using the dual domain material point method combined with molecular dynamics

Here in this work we combine the dual domain material point method with molecular dynamics in an attempt to create a multiscale numerical method to simulate materials undergoing large deformations with high strain rates. In these types of problems, the material is often in a thermodynamically nonequilibrium state, and conventional constitutive relations or equations of state are often not available. In this method, the closure quantities, such as stress, at each material point are calculated from a molecular dynamics simulation of a group of atoms surrounding the material point. Rather than restricting the multiscale simulation in a small spatial region, such as phase interfaces, or crack tips, this multiscale method can be used to consider nonequilibrium thermodynamic effects in a macroscopic domain. This method takes the advantage that the material points only communicate with mesh nodes, not among themselves; therefore molecular dynamics simulations for material points can be performed independently in parallel. The dual domain material point method is chosen for this multiscale method because it can be used in history dependent problems with large deformation without generating numerical noise as material points move across cells, and also because of its convergence and conservation properties. In conclusion, to demonstrate the feasibility and accuracy of this method, we compare the results of a shock wave propagation in a cerium crystal calculated using the direct molecular dynamics simulation with the results from this combined multiscale calculation.

36 MATERIALS SCIENCE↗

A high-order Lagrangian discontinuous Galerkin hydrodynamic method for quadratic cells using a subcell mesh stabilization scheme

We present here a Lagrangian discontinuous Galerkin (DG) hydrodynamic method that is up to third-order accurate using subcell mesh stabilization (SMS) for compressible flows on quadratic meshes in two-dimensional (2D) Cartesian coordinates. Similar to the second-order accurate Lagrangian DG method with linear meshes, the physical evolution equations for the specific volume, velocity, and specific total energy are discretized using a modal DG method with Taylor series polynomials. The Riemann velocity at the vertices of a curvilinear cell, and the corresponding surface forces, are calculated by solving a multidirectional approximate Riemann problem. Curvilinear cells (e.g., quadratic quadrilateral meshes in this work) have many deformational degrees of freedom, and with these cells, they can deform in unphysical ways. Likewise, the Riemann solution at an edge vertex differs from the one at the corner of a cell. With SMS, each quadratic quadrilateral cell is decomposed into four quadrilateral subcells, that move in a Lagrangian manner. The edge vertex is surrounded by four subcells so that it is similar to the vertex at the cell corner. SMS can detect inconsistent density fields between the cell and subcells. The difference between these two density fields is used to correct the stress (pressure) input to the Riemann solver. This SMS scheme enables stable mesh motion and accurate solutions in the context of a Lagrangian high-order DG method that is up to third-order with quadratic cells. We also present effective limiting strategies that ensure monotonicity of the primitive variables with the high-order DG method. This Lagrangian DG hydrodynamic method with SMS conserves mass, momentum, and total energy. A suite of test problems are calculated to demonstrate the designed order of accuracy (up to third-order accurate) of this method, and that the Lagrangian DG method using SMS preserves cylindrical symmetry on 1D radial flow problems with an equal-angle polar quadratic mesh.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗