Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Leveraging generative adversarial networks to create realistic scanning transmission electron microscopy images

Abstract The rise of automation and machine learning (ML) in electron microscopy has the potential to revolutionize materials research through autonomous data collection and processing. A significant challenge lies in developing ML models that rapidly generalize to large data sets under varying experimental conditions. We address this by employing a cycle generative adversarial network (CycleGAN) with a reciprocal space discriminator, which augments simulated data with realistic spatial frequency information. This allows the CycleGAN to generate images nearly indistinguishable from real data and provide labels for ML applications. We showcase our approach by training a fully convolutional network (FCN) to identify single atom defects in a 4.5 million atom data set, collected using automated acquisition in an aberration-corrected scanning transmission electron microscope (STEM). Our method produces adaptable FCNs that can adjust to dynamically changing experimental variables with minimal intervention, marking a crucial step towards fully autonomous harnessing of microscopy big data.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Order-disorder phase transformations in quaternary pyrochlore oxide system: Investigated by X-ray diffraction, transmission electron microscopy and Raman spectroscopic techniques

Order-disorder transformations in a quaternary pyrochlore oxide system, Ca-Y-Zr-Ta-O, were studied by powder X-ray diffraction (XRD) method, transmission electron microscope (TEM) and FT-NIR Raman spectroscopic techniques. The solid solutions in different ratios, 4:1, 2:1, 1:1, 1:2, 1:4, 1:6, of CaTaO{sub 3.5} and YZrO{sub 3.5} were prepared by the conventional high temperature ceramic route. The XRD results and Rietveld analysis revealed that the crystal structure changed from an ordered pyrochlore structure to a disordered defect fluorite structure as the ratios of the solid solutions of CaTaO{sub 3.5} and YZrO{sub 3.5} were changed from 4:1 to 1:4. This structural transformation in the present system is attributed to the lowering of the average cation radius ratio, r{sub A}/r{sub B} as a result of progressive and simultaneous substitution of larger cation Ca{sup 2+} for Y{sup 3+} at A sites and smaller cation Ta{sup 5+} for Zr{sup 4+} at B sites. Raman spectroscopy and TEM analysis corroborated the XRD results. - Graphical abstract: Selected area electron diffraction (SAED) patterns showed highly ordered diffraction maxima with characteristic superlattice weak diffraction spots of the pyrochlore structure for (a) Ca{sub 0.6}7Y{sub 1.33}Zr{sub 1.33}Ta{sub 0.33}O{sub 7} (C2YZT2) and bright diffraction maxima arranged in a ring pattern of the fluorite structure for (b) Ca{sub 0.29}7Y{sub 1.71}Zr{sub 1.71}Ta{sub 0.29}O{sub 7} (CY6Z6T).

36 MATERIALS SCIENCE↗

Soil Analysis Micro-Mission Concepts Derived from the MSP 2001 Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatic environment, and arrays of material patches to study abrasion and adhesion. Heritage will be all-important for low cost micro-missions, and adaptations of instruments developed for the Pathfinder, '98 and '01 Landers should be strong contenders for '03 flights. This talk has three objectives: (1) Familiarize the audience with MECA instrument capabilities; (2) present concepts for stand-alone and/or mobile versions of MECA instruments; and (3) broaden the context of the MECA instruments from human exploration to a comprehensive scientific survey of Mars. Due to time limitations, emphasis will be on the chemistry and microscopy experiments. Ion-selective electrodes and related sensors in MECA's wet-chemistry laboratory will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases in wet Martian soil. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential, and experiments will include cyclic voltammetry and anodic stripping. For experiments beyond 2001, enhancements could allow multiple use of the cells (for mobile experiments) and reagent addition (for quantitative mineralogical and exobiological analysis). MECA's microscopy station combines optical and atomic-force microscopy (AFM) in an actively focused, controlled illumination environment to image particles from millimeters to nanometers in size. Careful selection of substrates allows controlled experiments in adhesion, abrasion, hardness, aggregation, magnetic and other properties. Special tools allow primitive manipulation (brushing and scraping) of samples. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined using an array of sample receptacles and collection substrates. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. Future implementations might enhance the optical microscopy with spectroscopy, or incorporate advanced AFM techniques for thermogravimetric and chemical analysis.

Hecht, M. H.↗

X-ray peak broadening analysis of AA 6061{sub 100-x} - x wt.% Al{sub 2}O{sub 3} nanocomposite prepared by mechanical alloying

Nanocrystalline AA 6061 alloy reinforced with alumina (0, 4, 8, and 12 wt.%) in amorphized state composite powder was synthesized by mechanical alloying and consolidated by conventional powder metallurgy route. The as-milled and as-sintered (573 K and 673 K) nanocomposites were characterized by X-ray diffraction (XRD) and transmission electron microscopy (TEM). The peaks corresponding to fine alumina was not observed by XRD patterns due to amorphization. Using high-resolution transmission electron microscope, it is confirmed that the presence of amorphized alumina observed in Al lattice fringes. The crystallite size, lattice strain, deformation stress, and strain energy density of AA 6061 matrix were determined precisely from the first five most intensive reflection of XRD using simple Williamson-Hall models; uniform deformation model, uniform stress deformation model, and uniform energy density deformation model. Among the developed models, uniform energy density deformation model was observed to be the best fit and realistic model for mechanically alloyed powders. This model evidenced the more anisotropic nature of the ball milled powders. The XRD peaks of as-milled powder samples demonstrated a considerable broadening with percentage of reinforcement due to grain refinement and lattice distortions during same milling time (40 h). The as-sintered (673 K) unreinforced AA 6061 matrix crystallite size from well fitted uniform energy density deformation model was 98 nm. The as-milled and as-sintered (673 K) nanocrystallite matrix sizes for 12 wt.% Al{sub 2}O{sub 3} well fitted by uniform energy density deformation model were 38 nm and 77 nm respectively, which indicate that the fine Al{sub 2}O{sub 3} pinned the matrix grain boundary and prevented the grain growth during sintering. Finally, the lattice parameter of Al matrix in as-milled and as-sintered conditions was also investigated in this paper. Research highlights: {yields} Integral breadth methods using various Williamson-Hall models were investigated for line profile analysis. {yields} Uniform energy density deformation model is observed to the best realistic model. {yields} The present analysis is used for understanding the stress and the strain present in the nanocomposites.

36 MATERIALS SCIENCE↗

Nanoscale mapping of point defect concentrations with $\mathrm{4D-STEM}$

Vacancies are missing atoms in a crystalline material, and occur both at equilibrium (varying with temperature) and out of equilibrium such as when crystalline materials are damaged with radiation or corrosion. While we know of their importance, particularly regarding diffusive mechanisms, it is not straightforward to experimentally measure their concentration or to visualize them directly. Traditionally, measurements such as positron annihilation spectroscopy and to some degree X-ray diffraction can measure average concentrations, but generally lack the ability to visualize or quantify a heterogenous concentration of vacancies that can occur at the level of individual defects and microstructural features. Here, we present a method to map vacancy concentrations and their distribution using local lattice parameter measurements with a high-resolution electron microscope. Our method utilizes a Au thin film as a model to demonstrate the method via four-dimensional scanning transmission electron microscopy (4D-STEM) by correlating the differences between changes in lattice parameter and the volumetric thermal expansion during in situ heating experiments. The vacancy mapping methodology is also applied to non-equilibrium defects accumulated in pure Al via knock-on electron beam irradiation. Our method demonstrates the ability to map point defect concentrations in heterogeneous systems in situ with nanometer spatial resolution. The result is a technique that can provide direct measurements of vacancy concentrations at the level of individual defects in studies of materials in and out of equilibrium.

36 MATERIALS SCIENCE↗

Inversion of dynamical Bragg intensities to complex structure factors by iterated projections. For Ultramic. 2020. ("Pico" Festschrift, May 2021)

We discuss a method for recovering complex structure factors from many simultaneously excited Bragg beam intensities is described. The method is applied to simulated transmission electron diffraction data over a wide range of crystal thickness and beam energies. The method is based on iterated projections between structure and scattering matrices, which are related by a matrix unitary transformation, exponential, which we invert. The algorithm removes multiple-scattering perturbations from diffraction data and might be extended to other fields, including X-ray and neutron diffraction and cryo-electron microscopy. Because coherent multiple scattering involves interference between Bragg beams, the method also solves the phase problem. Unlike dynamical inversion from electron microscope images or ptychography data, the method, which starts with Bragg beam intensities, provides complex structure factors unaffected by focusing errors or resolution limitations imposed by lenses. We provide inversions from simulated data with 441 simultaneously excited Bragg beams over a range of thickness and beam energy. We discuss the retrieval of chirality information from enantiomorphs, the efficient incorporation of symmetry information using the irreducible representation of the group of structure matrices, and the effect of HOLZ lines to provide three-dimensional information.

97 MATHEMATICS AND COMPUTING↗

4D-STEM of Beam-Sensitive Materials

We report that a scanning electron nanobeam diffraction, or 4D-STEM (four-dimensional scanning transmission electron microscopy), is a flexible and powerful approach to elucidate structure from "soft" materials that are challenging to image in the transmission electron microscope because their structure is easily damaged by the electron beam. In a 4D-STEM experiment, a converged electron beam is scanned across the sample, and a pixelated camera records a diffraction pattern at each scan position. This four-dimensional data set can be mined for various analyses, producing maps of local crystal orientation, structural distortions, crystallinity, or different structural classes. Holding the sample at cryogenic temperatures minimizes diffusion of radicals and the resulting damage and disorder caused by the electron beam. The total fluence of incident electrons can easily be controlled during 4D-STEM experiments by careful use of the beam blanker, steering of the localized electron dose, and by minimizing the fluence in the convergent beam thus minimizing beam damage. This technique can be applied to both organic and inorganic materials that are known to be beam-sensitive; they can be highly crystalline, semicrystalline, mixed phase, or amorphous. One common example is the case for many organic materials that have a π-π stacking of polymer chains or rings on the order of 3.4-4.2 Å separation. If these chains or rings are aligned in some regions, they will produce distinct diffraction spots (as would other crystalline spacings in this range), though they may be weak or diffuse for disordered or weakly scattering materials. We can reconstruct the orientation of the π-π stacking, the degree of π-π stacking in the sample, and the domain size of the aligned regions. This Account summarizes illumination conditions and experimental parameters for 4D-STEM experiments with the goal of producing images of structural features for materials that are beam-sensitive. We will discuss experimental parameters including sample cooling, probe size and shape, fluence, and cameras. 4D-STEM has been applied to a variety of materials, not only as an advanced technique for model systems, but as a technique for the beginning microscopist to answer materials science questions. It is noteworthy that the experimental data acquisition does not require an aberration-corrected TEM but can be produced on a variety of instruments with the right attention to experimental parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: Direct measurement of the point-to-point resolution for microns-thick specimens in the ultrahigh-voltage electron microscope

We report on a direct measurement method and results of the point-to-point resolution for microns-thick amorphous specimens in the ultrahigh-voltage electron microscope (ultra-HVEM). We first obtain the ultra-HVEM images of nanometer gold particles with different sizes on the top surfaces of the thick epoxy-resin specimens. Based on the Rayleigh criterion, the point-to-point resolution is then determined as the minimum distance between centers of two resolvable tangent gold particles. Some values of resolution are accordingly acquired for the specimens with different thicknesses at the accelerating voltage of 2 MV, for example, 18.5 nm and 28.4 nm for the 5 {mu}m and 8 {mu}m thick epoxy-resin specimens, respectively. The presented method and results provide a reliable and useful approach to quantifying and comparing the achievable spatial resolution for the thick specimens imaged in the mode of transmission electron including the scanning transmission electron microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multilayer grating with a novel layer structure for a flat-field spectrograph attached to transmission electron microscopes in energy region of 2-4 keV

A multilayer mirror with a novel layer structure to uniformly enhance the reflectivity in a few keV energy range at a fixed angle of incidence is invented and applied to a multilayer grating for use in a flat-field spectrograph attached to a conventional electron microscope. The diffraction efficiency of the fabricated multilayer grating having the new layer structure is evaluated at the angle of incidence of 88.65 deg. in the energy region of 2.1-4.0 keV. It is shown that the multilayer grating is effective to uniformly enhance the diffraction efficiency and able to be practically used in this energy region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Views of Materials through Aberration-corrected STEM

The successful correction of third-order and, more recently, fifth-order aberrations has enormously enhanced the capabilities of the scanning transmission electron microscope (STEM), by not only achieving record resolution, but also allowing near 100% efficiency for electron energy loss spectroscopy, and higher currents for two-dimensional spectrum imaging. These advances have meant that the intrinsic advantages of the STEM, incoherent imaging and simultaneous collection of multiple complementary images can now give new insights into many areas of materials physics. Here, we review a number of examples, mostly from the field of complex oxides, and look towards new directions for the future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomistic mechanisms of water vapor–induced surface passivation

The microscopic mechanisms underpinning the spontaneous surface passivation of metals from ubiquitous water have remained largely elusive. Here, using in situ environmental electron microscopy to atomically monitor the reaction dynamics between aluminum surfaces and water vapor, we provide direct experimental evidence that the surface passivation results in a bilayer oxide film consisting of a crystalline-like Al(OH) 3 top layer and an inner layer of amorphous Al 2 O 3 . The Al(OH) 3 layer maintains a constant thickness of ~5.0 Å, while the inner Al 2 O 3 layer grows at the Al 2 O 3 /Al interface to a limiting thickness. On the basis of experimental data and atomistic modeling, we show the tunability of the dissociation pathways of H 2 O molecules with the Al, Al 2 O 3 , and Al(OH) 3 surface terminations. The fundamental insights may have practical significance for the design of materials and reactions for two seemingly disparate but fundamentally related disciplines of surface passivation and catalytic H 2 production from water.

36 MATERIALS SCIENCE↗

Development of Scanning Ultrafast Electron Microscope Capability.

Modern semiconductor devices rely on the transport of minority charge carriers. Direct examination of minority carrier lifetimes in real devices with nanometer-scale features requires a measurement method with simultaneously high spatial and temporal resolutions. Achieving nanometer spatial resolutions at sub-nanosecond temporal resolution is possible with pump-probe methods that utilize electrons as probes. Recently, a stroboscopic scanning electron microscope was developed at Caltech, and used to study carrier transport across a Si p-n junction [ 1 , 2 , 3 ] . In this report, we detail our development of a prototype scanning ultrafast electron microscope system at Sandia National Laboratories based on the original Caltech design. This effort represents Sandia's first exploration into ultrafast electron microscopy.

47 OTHER INSTRUMENTATION↗

Sporulation and ultrastructure in a late Proterozoic cyanophyte - Some implications for taxonomy and plant phylogeny

Electron microscopical studies of a morphologically diverse, coccoid, presumably late Proterozoic blue-green alga are here reported. They show, together with light microscopy, that the form studied is widespread in the Cordilleran geosyncline, extend the record of well-defined endosporangia perhaps 700 million years into the past, and reveal previously unrecorded ultrastructural details. Coming from northeastern Utah, southwestern Alberta, and east central Alaska, these minute fossils belong to the recently described, morphologically diverse taxon Sphaerocongregus variabilis Moorman, are related to living entophysalidaceans, and have affinities with both the chroococcalean and chamaesiphonalean cyanophytes. Included in the morphological modes displayed by this alga are individual unicells, coenobial clusters of unicells, and a range of endosporangia comparable to those described for living entophysalidaceans. Scanning and transmission electron microscopy reveal that the endospores are commonly embedded in a vesicular matrix, that some of them show what appears to be a bilaminate or perhaps locally multilaminate wall structure, and that some remain together to mature as coenobial clones or 'colonies'. Taxonomic classification and phylogeny are discussed.

Cloud, P.↗

The response of single human cells to zero-gravity

Microscopic and histochemical evaluations of human embrionic lung cells after exposure to zero-gravity are reported. Growth curves, DNA microspectrophotometry, phase microscopy, and ultrastructural studies of fixed cells revealed no effects on the cultures. Minor unexplained differences have been found in biochemical constituents of the samples.

Montgomery, P. O., Jr.↗

Application of surface analysis to solve problems of wear

Results are presented for the use of surface analytical tools including field ion microscopy, Auger emission spectroscopy analysis (AES), cylindrical mirror Auger analysis and X-ray photoelectron spectroscopy (XPS). Data from the field ion microscope reveal adhesive transfer (wear) at the atomic level with the formation of surface compounds not found in the bulk, and AES reveals that this transfer will occur even in the presence of surface oxides. Both AES and XPS reveal that in abrasive wear with silicon carbide and diamond contacting the transition metals, the surface and the abrasive undergo a chemical or structural change which effects wear. With silicon carbide, silicon volatilizes leaving behind a pseudo-graphitic surface and the surface of diamond is observed to graphitize.

Buckley, D. H.↗

Comparative functional ultrastructure of two hypersaline submerged cyanobacterial mats - Guerrero Negro, Baja California Sur, Mexico, and Solar Lake, Sinai, Egypt

The ultrastructure of the submerged microbial mat from the Solar Lake (SL), Egypt, was compared to that of samples from the Guerrero Negro (GN), Mexico, salt pans. The locations and distributions of the main organisms were determined light microscopy, and the corresponding ultrathin sections were examined under TEM; chemical microprofile analyses were carried out on the day of sampling for microscopic studies. Both communities were found to be dominated by Microleus chthonoplastes, although several morphological species found in the GN mat were absent from the SL mat, including the Tropica nigra and the 'big' Microleus chthonoplastes component. The chemical microprofiles of oxygen, sulfide, pH, and the oxygenic photosynthesis in the two mats were virtually identical. In both mats, the photic zone was restricted to the upper 800 microns of the mat, and oxygenic photosynthesis was detected down to 600 microns.

D'Amelio, Elisa D'antoni↗

Surveys of ISS Returned Hardware for MMOD Impacts

Since February 2001, the Hypervelocity Impact Technology (HVIT) group at the Johnson Space Center in Houston has performed 26 post-flight inspections on space exposed hardware that have been returned from the International Space Station. Data on 1,024 observations of MMOD damage have been collected from these inspections. Survey documentation typically includes impact feature location and size measurements as well as microscopic photography (25-200x). Sampling of impacts sites for projectile residue was performed for the largest features. Results of Scanning Electron Microscopy (SEM) analysis to discern impactor source is included in the database. This paper will summarize the post-flight MMOD inspections, and focus on two inspections in particular: (1) Pressurized Mating Adapter-2 (PMA-2) cover returned in 2015 after 1.6 years exposure with 26 observed damages, and (2) Airlock shield panels returned in 2010 after 8.7 years exposure with 58 MMOD damages. Feature sizes from the observed data are compared to predictions using the Bumper risk assessment code.

Hyde, James↗

Isothermal oxidation of zirconium using steam

Oxidation of zirconium and its alloys under any atmosphere is generally characterised by a protective and non-protective stage. During the protective stage, the kinetics of oxidation are quasi-parabolic, while the oxide scale formed on the surface of the metal is black, compact, and protective in nature. For the non-protective stage, the oxidation rate becomes linear, while the protective oxide film turns into a deteriorated white scale. Breakaway is known as the transition point from protective to non-protective stage. The actual mechanism leading to breakaway of zirconium is still a matter of controversy, however some of the most common factors affecting breakaway are the following: - Impurities on the metal (Carbon, Oxygen, Nitrogen); - Oxidizing atmosphere (Presence of H{sub 2}O (g) or N{sub 2} (g)); - Sample preparation (Chemically etched or polished); - Temperature (LWR, LOCA). This research investigates the effect of temperature on 'breakaway' when zirconium is oxidized isothermally in steam for 60 min at 800 and 900 deg. C using thermogravimetric and optical microscopic imaging techniques. 1. Steam isothermal oxidations were performed on zirconium at 800 and 900 deg. C using a Thermogravimetric Analyzer (TGA). 2. Log-log plots of mass gain vs time were obtained from thermogravimetric results to calculate the reaction orders (n) and reaction rate constants (K) during oxidation. 3. Results of the kinetics of reaction were correlated with optical microscopic images form Light Microscope (LM) and Scanning Electron Microscope (SEM). Breakaway depends very strongly on temperature. At 800 deg. C, the weight gain followed a cubic-parabolic behaviour with evidence of a protective oxide film. On the other hand, oxidation at 900 deg. C showed signs of breakaway since the oxide film was cracked and oxidation rate was almost linear throughout the reaction.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗