Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Embedding of Optical Fibers with Electric Field Assisted Sintering

The Electric Field Assisted Sintering (EFAS) technique was used for embedding the fibers, involving rapid heating via an electric current and pressure, reducing fiber exposure to high temperatures. Stainless steel guide tubes were inserted at the fiber-matrix junctions to prevent fiber breakage during the sintering process. The study varied key EFAS parameters—temperature (800°C to 980°C), pressure (40-50 MPa), and hold time (5-10 minutes)—to assess how they influenced fiber embedding. After embedding, the fibers were inspected using optical frequency domain reflectometry (OFDR) to evaluate optical losses and strain along the fiber length. The OFDR scans confirmed that the fibers remained intact, and subsequent transmission tests demonstrated no macroscopic fractures. The embedded samples were also analyzed using scanning electron microscopy (SEM) and X-ray computed tomography (CT) scans. These tests confirmed good bonding between the fiber and matrix with no cracking, though some porosity was present in samples fabricated at lower temperatures. At higher temperatures (980°C), the fiber-matrix bonding was continuous and defect-free, with metal coatings aiding in the bonding process. Elemental analysis showed interdiffusion between the fiber coatings and matrix materials, particularly between the gold coating and stainless steel. Helium leak tests revealed that lower sintering temperatures resulted in matrix porosity, causing leaks, but samples fabricated at 980°C were leak-tight.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Performance Testing of Enhanced Linear Variable Integrated Sensor (ELVIS III) for LVDTs

The Enhanced Linear Variable Intrinsic Sensor (ELVIS) was a 2024 breakthrough discovery by Idaho National Laboratory (INL) in terms of further innovating the usage of all linear variable differential transformers (LVDTs) and enhancing their performance in harsh environments. In irradiation tests conducted within material test reactors (MTRs), LVDTs with an internal temperature sensing capability can address several critical challenges. This report focuses on performance testing of the ELVIS III device with new hybrid LVDTs provided by the Institute for Energy Technology (IFE), which is the world’s sole supplier of nuclear-grade LVDTs. The ELVIS III device was evaluated in terms of temperature showcasing promising results comparable to a typical type-K thermocouple (TC).

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

INL_Intern_Poster_ColeBailey [Poster]

Understanding the thermophysical properties of molten salts is crucial for the advancement of nuclear fuels. This project presents the design of a custom differential thermal analyzer (DTA) that utilizes non-contact ultrasonic mixing to agitate samples and prevent supercooling. The supercooling effect occurs when a liquid is below its freezing point without solidifying. This can be observed when a liquid in a freezer instantly transitions to its solid phase upon disturbance. By avoiding this effect, accurate transition temperatures of molten salts can be gathered for future applications. Initial mixing results were promising, leading to further refinement of the waveguides using ABAQUS to maximize input energy into the fluid. Future work will focus on integrating both mixing and cooling in conjunctions to observe the avoided effect.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Analysis of temperature effects on self-powered neutron detectors in a gamma field

Self-powered neutron detectors (SPND) are small, robust, in-core radiation sensors that have the potential to operate in high temperature environments (above 600°C). However, previous experiments indicated temperature related effects in the form of displacement currents. Given the recent irradiation at The Ohio State University Research Reactor using a delayed-response rhodium-based SPND alongside a prompt-response tantalum-based SPND, it was concluded that only low-energy electrons from gamma interactions were the cause of these temperature effects. A series of heated gamma irradiations with temperatures up to 750°C of SPNDs were performed at the Advanced Test Reactor Gamma Facility in order to better characterize these displacement currents. The results from the experiments demonstrated a strong relation between the displacement currents that occurred during temperature ramps to thermoluminescence (TL) glow peaks—the SPND with Al2O3 insulation has one glow peak within 750°C and the SPND with MgO has three. A demonstration was performed to calculate the trap energy levels of the displacement currents through TL glow peak analysis. Unfortunately, the methods employed provided inconsistent results, requiring an updated model based on ongoing irradiation instead of post-irradiation measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Thermal Performance of Neutron Sensor Qualification Device

The neutron sensor qualification device was developed to provide a temperature-controlled environment for neutron sensors and dosimetry, enabling irradiation in a neutron field at the Armed Forces Radiobiology Research Institute (AFRRI) TRIGA reactor facility. The device, constructed from low-activation and low neutron cross-section materials, features a modular tube furnace design with three independently controlled heating zones for controlling axial temperature distribution. Laboratory testing validated the device's thermal performance, including uniform temperature distribution with less than 6°C variation across the central region, a steady-state operational temperature of 350°C achieved in approximately 3 hours, and a cooling time constant of 3.5 hours. External surface temperatures remained safe for handling, with the surrounding aluminum structure remaining at ambient conditions. The results confirm the device’s suitability for neutron sensor qualification experiments, with potential for future operation at higher temperatures and further optimization of performance.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Overview of IMPACT Data Acquisition System and Data Reduction Process

This report documents the development of the data acquisition system (DAS) and data reduction methodologies for the Irradiated Material Property Accelerated Characterization Test (IMPACT) experiment at the Advanced Test Reactor (ATR). The IMPACT experiment is designed to enable in-pile measurement of thermal conductivity in metallic nuclear fuels, specifically U-10Zr, using an instrumented thermal conductivity probe. The DAS supports both passive temperature monitoring and active thermal interrogation of the probe through controlled AC and DC excitation. Significant modifications to laboratory-scale systems were required to accommodate the higher resistance paths associated with the in-pile application. Custom electronics and relay-controlled measurement sequencing were developed to enable the measurement and sufficient power delivery to the sensing region. A reduced-order, axisymmetric thermal model based on the thermal quadrupoles method is presented to support data interpretation. This model enables efficient evaluation of transient heat transfer behavior and facilitates solution of the inverse problem required to extract thermal properties from measured signals. Multiple boundary condition formulations are discussed to address varying experimental time scales and geometries. Additionally, machine learning techniques are introduced to support data reduction and improve confidence in inverse solutions. Convolutional neural networks are applied to identify the presence of gas gaps and other evolving geometric features that significantly impact thermal response during irradiation. These efforts contribute to the broader integration of digital twin frameworks and real-time modeling capabilities within the Advanced Fuels Campaign.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Quantized Constant-Q Gabor Atoms for Sparse Binary Representations of Cyber-Physical Signatures

Increased data acquisition by uncalibrated, heterogeneous digital sensor systems such as smartphones present new challenges. Binary metrics are proposed for the quantification of cyber-physical signal characteristics and features, and a standardized constant-Q variation of the Gabor atom is developed for use with wavelet transforms. Two different continuous wavelet transform (CWT) reconstruction formulas are presented and tested under different signal to noise ratio (SNR) conditions. A sparse superposition of Nth order Gabor atoms worked well against a synthetic blast transient using the wavelet entropy and an entropy-like parametrization of the SNR as the CWT coefficient-weighting functions. The proposed methods should be well suited for sparse feature extraction and dictionary-based machine learning across multiple sensor modalities.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Reaction-Induced Fracturing of Porous Carbonate Rocks during Volume-Increasing Replacement by Witherite

Volume-increasing replacement reactions can lead either to fracturing of the parent phase or to the formation of cohesive layers that passivate further reaction, but the factors that drive one outcome or the other are not understood. In this experimental study, we investigated the volume-increasing replacement of carbonate rocks (consisting of CaCO 3 and CaMg(CO 3 ) 2 ) of different porosity by witherite (BaCO 3 ). Samples were characterized using scanning electron microscopy, Raman spectroscopy, small-angle neutron/X-ray scattering, X-ray tomography, and scanning transmission electron microscopy. We observed the formation of a witherite reaction layer and witherite formation within pores and along grain boundaries. Despite this being a volume-increasing replacement reaction, newly formed witherite was porous, potentially allowing further replacement. Filled fractures were observed in the low-porosity carbonates, whereas witherite formed within pores in high-porosity carbonates. We conclude that fracturing of the parent phase versus passivation is contingent on the initial microstructure of the parent with an optimal degree of porosity required for fracturing.

Calcite↗

Chemical, Biological, Radiological, Nuclear, and Explosive (CBRNE) Science and the CBRNE Science Medical Operations Science Support Expert (CMOSSE)

We report a national need is to prepare for and respond to accidental or intentional disasters categorized as chemical, biological, radiological, nuclear, or explosive (CBRNE). These incidents require specific subject-matter expertise, yet have commonalities. We identify 7 core elements comprising CBRNE science that require integration for effective preparedness planning and public health and medical response and recovery. These core elements are (1) basic and clinical sciences, (2) modeling and systems management, (3) planning, (4) response and incident management, (5) recovery and resilience, (6) lessons learned, and (7) continuous improvement. A key feature is the ability of relevant subject matter experts to integrate information into response operations. We propose the CBRNE medical operations science support expert as a professional who (1) understands that CBRNE incidents require an integrated systems approach, (2) understands the key functions and contributions of CBRNE science practitioners, (3) helps direct strategic and tactical CBRNE planning and responses through first-hand experience, and (4) provides advice to senior decision-makers managing response activities. Recognition of both CBRNE science as a distinct competency and the establishment of the CBRNE medical operations science support expert informs the public of the enormous progress made, broadcasts opportunities for new talent, and enhances the sophistication and analytic expertise of senior managers planning for and responding to CBRNE incidents.

61 RADIATION PROTECTION AND DOSIMETRY↗

Resolving hot spot microstructure using x-ray penumbral imaging (invited)

We have developed and fielded x-ray penumbral imaging on the National Ignition Facility in order to enable sub-10 μm resolution imaging of stagnated plasma cores (hot spots) of spherically shock compressed spheres and shell implosion targets. By utilizing circular tungsten and tantalum apertures with diameters ranging from 20 μm to 2 mm, in combination with image plate and gated x-ray detectors as well as imaging magnifications ranging from 4 to 64, we have demonstrated high-resolution imaging of hot spot plasmas at x-ray energies above 5 keV. Here we give an overview of the experimental design criteria involved and demonstrate the most relevant influences on the reconstruction of x-ray penumbral images, as well as mitigation strategies of image degrading effects like over-exposed pixels, artifacts, and photon limited source emission. We describe experimental results showing the advantages of x-ray penumbral imaging over conventional Fraunhofer and photon limited pinhole imaging and showcase how internal hot spot microstructures can be resolved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recrystallization suppression through dispersion-strengthening of tungsten

Tungsten is the material of choice for the divertor region of future nuclear fusion reactors, an environment that will expose plasma-facing components (e.g. divertor, etc...) to high temperatures and transient high heat flux events. Under these conditions, recrystallization and grain growth of tungsten can occur, leading to undesirable microstructural and mechanical property changes. Therefore, there is a need to raise the recrystallization temperature of tungsten and limit the kinetics of the recrystallization and grain growth processes. In this work, we examine the effect of different types (TiC vs. TaC vs. ZrC) and different concentrations (1.1 vs. 5 vs. 10 wt.%) of dispersed second phase particles in a tungsten matrix on the high temperature performance. Additionally, the addition of second-phase particles effectively increases the temperature of and time for recrystallization and slow grain growth; however, the addition of a high weight fraction of particles alters the surface chemistry, which may impact subsequent plasma-surface interactions. These results show that the addition of small concentrations of dispersed particles can be effectively employed in tungsten to raise the upper operating temperature limit for tungsten in a fusion reactor.

36 MATERIALS SCIENCE↗

TPC measurement support

A new instrument for high precision fission cross sections, the Time Projection Chamber (TPC), is being developed by the NIFFTE (Neutron Induced Fission Fragment Tracking Experiment) collaboration which consists of six universities and three national laboratories. The measurements with the TPC will be carried out at the Los Alamos Neutron Science Center (LANSCE), and one of the roles of the LANL collaborators is to support the TPC measurement program. That support for FY12 is outlined in this report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗