Search NASASearch

SEARCH · Search NASA

Results for “Propulsion, Refractory, and Coating Materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,565 records · Page 68

Performance of a Regenerative Fuel Cell System for the Lunar Surface

Regenerative fuel cells (RFCs) are an attractive energy storage solution for lunar missions as a technology capable of providing a higher specific energy (i.e., W∙h/kg) than state-of-the-art packaged Li-ion battery systems. An RFC consists of the (1 & 2) electrochemical stacks (chemical to electrical energy conversion to supply electricity to an external load, i.e. the fuel cell reaction, and electrical to chemical energy conversion of supplied electrical power to dissociate water into hydrogen and oxygen gases, i.e. water electrolysis), (3) fluidic conditioning, (4) reactant storage, (5) avionics, (6) power management and distribution (PMAD), and (7) thermal management. NASA’s Glenn Research Center has designed, assembled, and tested a breadboard RFC sys-tem capable of operating autonomously for multiple simulated lunar day/night cycles in a laboratory environment. The system is comprised of a non-flow through proton exchange membrane (PEM) fuel cell stack and a liquid-anode feed PEM electrolyzer (EZ) stack designed to electrochemically compress the reactants at balanced pressures up to 12.4 MPa (1800 psia). The fluidic conditioning, avionics, PMAD, and thermal management sub-systems are largely comprised of commercial-off-the-shelf components for this system-level development effort. The hardware is controlled by a CubeSat space processor running an operational program based on core flight architecture that can control the RFC hardware autonomously through a state machine with fault monitoring. The testing results highlighted here were completed with the system in an open-loop configuration such that reactants generated through water electrolysis were vented while gas cylinders supplied fuel cell operation. The breadboard operated autonomously, but there were five unplanned transitions to a safe state that required a manual restart after reviewing the data, determining a root cause, and implementing a solution. Four of the transitions were caused by the thermal management subsystem and the fifth was caused by a water management control issue in the EZ sub-system. The RFC system operated for over 550 hours with the final cycle being slightly abbreviated due to reasons unrelated to system performance.

Kerrigan Cain

An Improved Theoretical Ni-Cd Battery Performance Model

Previous reports have shown how a battery model was developed using porous electrode theory. Since then the model has been upgraded and expanded. These upgrades include oxygen reation and positive electrode intercalation and proton diffusion. The effects of additional details of the solid state physics of the nickel electrode will be reported here.

battery

Diverse organic molecules on Mars revealed by the first SAM TMAH experiment

The search for organic matter on Mars has rapidly evolved in the past decade with simple aromatic, S-heterocycles, and aliphatic organic molecules detected in Gale crater. We report the in situ detection of >20 organic molecules from clay-bearing sandstones in the ~3.5-billion-year-old Knockfarrill Hill member of Glen Torridon, Gale crater, by the Sample Analysis at Mars instrument suite onboard the Curiosity rover. These molecules were liberated by the onboard tetramethylammonium hydroxide wet chemistry experiment. Diverse thermochemolysis products, including benzothiophene, methyl benzoate, and single and dicyclic aromatic molecules were released and detected by evolved gas analysis and gas chromatography-mass spectrometry. Results indicate the experiment successfully released molecules preserved in ancient macromolecular or free organic matter within Martian bedrock despite ~3.5 billion years of diagenesis and radiation exposure.

Amy J Williams

The 2001 NASA Aerospace Battery Workshop

This document contains the proceedings of the 34th annual NASA Aerospace Battery Workshop, hosted by the Marshall Space Flight Center, November 27-29, 2001. The workshop was attended by scientists and engineers from various agencies of the US Government, aerospace contractors, and battery manufacturers, as well as international participation in like kind. The subjects covered included nickel-hydrogen, nickel-cadmium, lithium-ion, and silver-zinc technologies.

Brewer, Jeff C.

Fifth Aerospace Mechanisms Symposium

Conference of structural design principles and mechanical engineering methods for aerospace mechanisms used in orbital and space flights

Bowden W Ward

Thermal expansion behavior of LDEF metal matrix composites

The effects of the space environment on the thermal expansion stability of metal matrix composites (graphite/Al and graphite/Mg) will be presented. A sample from each category of metal matrix composites mounted on the leading and trailing edge was chosen for analysis of the temperature-time-thermal strain histories. Typical thermal expansion curves over the same range of temperature were selected at the beginning, mid, and end of the recording duration. The thermal expansion of selected post-flight LDEF samples were measured over the same range of temperature in the laboratory using a Michelson laser interferometer. The thermal strains were monitored concurrently with a laser interferometer and a mounted strain gage.

T. D. Le

Battery charge control: Which approach is best?

The question of the best approach for battery charge control is addressed from two points of view: from the battery point-of-view; and from the spacecraft/mission point-of-view. In terms of performance, more aggressive charging can result in higher discharge voltage and capacity; however, aggressive charging usually implies more overcharge at higher rates and a concomitant higher end of charge temperature (higher stress, shorter life). In terms of life, benign charging can result in lower discharge voltage and capacity (poorer performance). Additionally, benign, or low stress charging, usually implies less overcharge at lower rates with lower end of charge temperature (lower stress, longer life). A discussion of these topics is presented in viewgraph form.

Lurie, Charles

Remote Guidance of a Mothership-Daughtership Formation for Asteroid Exploration

This work presents an application of Model Predictive Control to maintain long-term stability for a three-satellite formation around the asteroid Apophis via remote guidance. The mothership and two daughterships perform tomographic characterization with a bistatic radar. The mothership estimates the states of all three spacecraft and determines the necessary control to maintain the desired antipodal daughtership states. An Extended Kalman Filter estimates the mothership states. A Batch Least Squares algorithm estimates the daughtership states and performs maneuver reconstruction for the mothership-administered thrust commands under thruster and gravitational uncertainty. The formulation maintains the antipodal angle with growing instability amidst these uncertainties.

Guidance

Control requirements for future battery systems

It is argued that sophisticated battery control systems are required to support the high power, high energy spacecraft secondary battery systems of the post 1985 time period. Four categories of battery control system functions are defined and discussed: battery operational control, auxiliary system control, battery system status indication and fault detection fault isolation. A concept for implementation of such a control system is also presented and discussed.

Masson, J. H.

Observations of the microclimate of a lake under cold air advective conditions

The moderating effects of Lake Apopka, Florida, on downwind surface temperatures were evaluated under cold air advective conditions. Point temperature measurements north and south of the lake and data obtained from the NOAA satellite and a thermal scanner flown at 1.6 km, indicate that, under conditions of moderate winds (approximately 4m/sec), surface temperatures directly downwind may be higher than surrounding surface temperatures by as much as 5 C. With surface wind speed less than 1m/sec, no substantial temperature effects were observed. Results of this study are being used in land use planning, lake level control and in agriculture for selecting planting sites.

R. G., Jr. Bill

Hubble Space Telescope: Battery Capacity Trend Studies

Battery cell wear out mechanisms and signatures are examined and compared to orbital data from the six on-orbit Hubble Space Telescope (HST) batteries, and the Flight Spare Battery (FSB) Test Bed at Marshall Space Flight Center (MSFC), which is instrumented with individual cell voltage monitoring. Capacity trend data is presented which suggests HST battery replacement is required in 2005-2007 or sooner.

Rao, M. Gopalakrishna

Evaluation of Low-Energy Hydrogen Separation Method Using Metal-Organic Frameworks (MOFs) for Closed-Loop ECLSS Air Revitalization (CLEAR)

The State-of-the-Art (SOA) air revitalization architecture onboard the International Space Station (ISS) recovered approximately 50% of the oxygen (O 2 ) from metabolic carbon dioxide (CO 2 ) via the Sabatier process from 2011 to 2017. O 2 recovery is currently constrained by the limited availability of reactant hydrogen (H 2 ) preventing complete conversion of CO 2 to H 2 O. Increasing O 2 recovery within Closed-Loop ECLSS is essential to reducing resupply mass for long-duration manned missions; specifically focusing on water (H 2 O) which supplies H 2 for Sabatier via water electrolysis. Past ground test endeavors at Marshall Space Flight Center (MSFC) have attempted to recover H 2 from Sabatier-produced CH 4 using technologies such as carbon vapor deposition (CVD) and plasma pyrolysis. The byproducts of these technologies can act as a catalyst poison or reactor deadload to the Sabatier reactor. Hydrogen separation techniques must be utilized to maintain the Sabatier catalyst during gas recycling and must be scalable, non-energy intensive, and safe to operate in a habitation setting. Research indicated that metal-organic frameworks (MOFs) could meet these criteria and were tested for their capability to capture the various carbon-based gaseous products of CVD and plasma pyrolysis such as acetylene (C 2 H 2 ), ethylene (C 2 H 4 ), ethane (C 2 H 6 ), and carbon monoxide (CO) which would purify the hydrogen gas stream passing through the MOF. A sub-scale adsorption column was developed by Marshall Space Flight Center to test three MOF candidates against a synthetic gas mixture comprised of process-relevant carbonous gases and hydrogen to evaluate the separation capability of the MOFs. The results of the hydrogen separation capability, isothermal desorption capability, and demonstrated cyclic reuse of the MOF are presented in this paper.

Kagen Crawford

User Interface Issues in Supporting Human-Computer Integrated Scheduling

A major problem in designing user interfaces for scheduling systems is one of allowing the human to become an integral part of the system. The human role in scheduling extends beyond the simple tasks of providing the input and accepting the output. Because of the inherent intractability of most real-world scheduling problems, intelligence must be incorporated into the scheduling process in order to reach an acceptable solution in a reasonable amount of time. Artificial Intelligence research has concentrated on identifying algorithms and heuristics for this purpose. However, interfaces which allow the scheduler to take advantage of human intelligence and allow the user insight into and influence over the planning process are also needed.

Lynne P Cooper

Extended Duration Orbiter Medical Project Microbial Air Sampler (STS-50/USML-1)

The Microbial Air Sampler was used on mission days 1, 7, and 13 in the Spacelab during STS-50/USML-1. Microbial air samples were collected using two types of media strips containing agar (Rose Bengal for yeast and molds, TSA for bacteria). The bacterial level found on day 1 was lower than experienced on previous Spacelab missions. A high level of fungi was present on day 1, however subsequent samples on days 7 and 13 did not indicate fungal growth. Bacterial growth was also minimized in this microgravity environment as the mission progressed. No pathogenic microorganisms were isolated, and the health risk from airborne microbes was minimal throughout the mission.

Duane L Pierson

A Predictive Bubble Point Pressure Model for Porous Liquid Acquisition Device Screens

This article presents a simplified model for porous screen channel liquid acquisition devices based on a maximum bubble point pressure method from Adamson and Gast (1997). To validate the model, three 304 stainless steel (325 × 2300, 450 × 2750, and 510 × 3600) mesh samples were tested in methanol, acetone, isopropyl alcohol, and water. Screen pores are estimated based on analysis from scanning electron microscopy, historical data, and current test data. Results show that the bubble point pressure is proportional to the surface tension of the fluid only when accounting for nonzero contact angles. The previous assumption that bubble point pressure scales inversely with effective pore diameter is shown to be invalid, as the second finest 450 × 2750 produced the highest bubble point of the three screens. The simplified bubble point model can be used to make predictions for any pure fluid when pore diameters are based on bubble point tests and not SEM analysis.

Liquid Acquisition Device

Multikilowatt Bipolar Nickel/Hydrogen Battery

High energy densities appear feasible. Nickel/hydrogen battery utilizing bipolar construction in common pressure vessel, addressing needs for multikilowatt storage for low-Earth-orbit applications, designed and 10-cell prototype model tested. Modular-concept-design 35-kW battery projected energy densities of 20 to 24 Wh/b (160 to 190 kj/kg) and 700 to 900 Wh/ft3 (90 to 110 MJ/m3) and incorporated significant improvements over state-of-the-art storage systems.

Source record

In-suit CO2 Washout Test System (ICWTS) for CO2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell