Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quantitative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Synthesis of FeCoNi nanoparticles by galvanostatic technique

Soft magnetic nanoparticles of FeCoNi have been becoming interesting objects for many researchers due to its potential application in electronic devices. One of the most promising methods for material preparation is the electrodeposition which capable of growing nanoparticles alloy directly onto the substrate. In this paper, we report our electrodeposition studies on nanoparticles synthesis using galvanostatic electrodeposition technique. Chemical composition of the synthesized FeCoNi was successfully controlled through the adjustment of the applied currents. It is revealed that the content of each element, obtained from quantitative analysis using atomic absorption spectrometer (AAS), could be modified by the adjustment of current in which Fe and Co content decreased at larger applied currents, while Ni content increased. The nanoparticles of Co-rich FeCoNi and Ni-rich FeCoNi were obtained from sulphate electrolyte at the range of applied current investigated in this work. Broad diffracted peaks in the X-ray diffractograms indicated typical nanostructures of the solid solution of FeCoNi.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Experimental evaluation of the response of micro-channel plate detector to ions with 10s of MeV energies

The absolute calibration of a microchannel plate (MCP) assembly using a Thomson spectrometer for laser-driven ion beams is described. In order to obtain the response of the whole detection system to the particles’ impact, a slotted solid state nuclear track detector (CR-39) was installed in front of the MCP to record the ions simultaneously on both detectors. The response of the MCP (counts/particles) was measured for 5–58 MeV carbon ions and for protons in the energy range 2–17.3 MeV. The response of the MCP detector is non-trivial when the stopping range of particles becomes larger than the thickness of the detector. Protons with energies E ≳ 10 MeV are energetic enough that they can pass through the MCP detector. Quantitative analysis of the pits formed in CR-39 and the signal generated in the MCP allowed to determine the MCP response to particles in this energy range. Moreover, a theoretical model allows to predict the response of MCP at even higher proton energies. This suggests that in this regime the MCP response is a slowly decreasing function of energy, consistently with the decrease of the deposited energy. These calibration data will enable particle spectra to be obtained in absolute terms over a broad energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced information content for three-dimensional localization and tracking using the double-helix point spread function with variable-angle illumination epifluorescence microscopy

The signal-to-noise ratio (SNR) and three-dimensional localization precision of a double helix point spread function (DH-PSF) can be significantly improved by applying variable-angle illumination epifluorescence microscopy (VAI, also commonly known as “pseudo-TIRF” or “quasi-TIRF”). In this paper, we performed a quantitative analysis of the dependence of SNR and localization precision on the number of measured photons and the incident angle for static particles under both low (at a planar index-matched interface) and high (within a porous silica matrix) fluorescent background conditions. We found that under noisier imaging conditions, the SNR and localization precision obtained using VAI are up to fivefold and threefold greater, respectively, than those obtained using epi-illumination. Finally and moreover, we demonstrate that the combination of DH-PSF and VAI can significantly improve the accuracy of the measured diffusion coefficient for mobile particles, even at a relatively large distance (50 μm) from the boundary of the optical cell.

42 ENGINEERING↗

Thermal diffusivity determination using heterodyne phase insensitive transient grating spectroscopy

The elastic and thermal transport properties of opaque materials may be measured using transient grating spectroscopy (TGS) by inducing and monitoring periodic excitations in both reflectivity and surface displacement. The “phase grating” response encodes both properties of interest, but complicates quantitative analysis by convolving temperature dynamics with surface displacement dynamics. Hence, thermal transport characteristics are normally determined using the “amplitude grating” response to isolate the surface temperature dynamics. Yet, this signal character requires absolute heterodyne phase calibration and contains no elastic property information. Here, a method is developed by which phase grating TGS measurements may be consistently analyzed to determine thermal diffusivity with no prior knowledge of the expected properties. To demonstrate this ability, the wavelength-dependent 1D effective thermal diffusivity of pure germanium is measured using this type of response and found to be consistent with theoretical predictions made by solving the Boltzmann transport equation. This ability to determine the elastic and thermal properties from a single set of TGS measurements will be particularly advantageous for new in situ implementations of the technique being used to study dynamic materials systems.

36 MATERIALS SCIENCE↗

Swelling of individual nanodomains in hydrated block copolymer electrolyte membranes

Here, we examine the swelling of nanostructured block copolymer electrolytes immersed in liquid water. A series of sulfonated polystyrene-b-polyethylene-b-polystyrene (S-SES) membranes having the same nominal chemical composition but two different morphologies are prepared by systematic changes in processing. We start with a membrane comprising a mixture of homopolymer polystyrene (hPS) and a polystyrene-b-polyethylene-b-polystyrene (SES) copolymer. hPS is subsequently selectively removed from the membrane and the polystyrene domains are sulfonated to give S-SES membranes. The morphology of the membranes is controlled by controlling Φ v , the volume fraction of hPS in the blended membrane. The morphology of the membranes was studied by small angle X-ray scattering (SAXS), cryogenic scanning transmission electron microscopy (cryo-STEM), and cryogenic electron tomography. The overall domain swelling measured by SAXS decreases slightly at Φ v = 0.29; a crossover from lamellar to bicontinuous morphology is obtained at the same value of Φ v . The bicontinuous morphologies absorb more water than the lamellar morphologies. By contrast, the nanodomain swelling of the bicontinuous membrane (120%) is slightly less than that of the lamellar membrane (150%). Quantitative analysis of the STEM images and electron tomography was used to determine the swelling on the hydrophilic and hydrophobic domains due to exposure to water. The hydrophilic sulfonated polystyrene-rich domain spacing increases while the hydrophobic polyethylene domain spacing decreases when the membranes are hydrated. The extent of increase and decrease is not a strong function of Φ v .

36 MATERIALS SCIENCE↗

Shear strain-induced anisotropic domain evolution in mixed-phase BiFeO 3 epitaxial films

Understanding and controlling the domain evolution under external stimuli in multiferroic thin films is critical to realizing nano-electronic devices, including for non-volatile memory, data storage, sensors, and optoelectronics. In this article, we studied the shear-strain effect on the domain evolution with temperature in highly strained BiFeO 3 thin films on rhombohedral LaAlO 3 sub-strates using a high-resolution synchrotron X-ray diffraction three dimensional-reciprocal space mapping (3D-RSM) technique. The results revealed significant biaxial, anisotropic, evolution behaviors of the mixed-phase ( M C + R' / T' phases) BiFeO 3 ferro-electric domains along the in-plane [100] and [010] axes. These biaxial, anisotropic, evolution behaviors were attributed to the shear-strain-modulated transition pathways of the mixed-phase ferroelectric domains. This viewpoint was further verified in the BiFeO 3 /LaSrAlO 4 (001) system in which no anisotropic evolution behaviors of the mixed-phase domains were found. This work sheds light on the quantitative analysis of domain evolution in multi-domain systems and demonstrates that the shear-strain effect could act as an effective tool to manipulate the domain behavior and control novel functionalities of ferroelectric thin films.

36 MATERIALS SCIENCE↗

Impact of non-Maxwellian electron velocity distribution functions on inferred plasma parameters in collective Thomson scattering

Optical collective Thomson scattering provides precise density and temperature measurements in numerous plasma-physics experiments. The accuracy of such measurements depends on the core assumption that the underlying electron distribution functions in under-dense laser-produced plasmas are Maxwellian. A statistically based, quantitative analysis of the errors in the measured electron density and temperature is presented when synthetic data calculated using a non-Maxwellian electron distribution function is fit assuming a Maxwellian electron distribution. Such analysis can lead to errors of up to 50% in temperature and 30% in density, in the specific case of super-Gaussian distributions characteristic of inverse bremsstrahlung heating. Furthermore including the proper family of non-Maxwellian electron distribution functions, as a fitting parameter, in Thomson-scattering analysis removes the model-dependent errors in the inferred parameters at a minimal cost to the statistical uncertainty.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Curvature distribution and autocorrelations in elliptic cylinders and cones

Not all micro-vessels (MV) are traditionally circular and there are examples of elliptic cylindrical MVs in life sciences, particularly if projected with a slant. Similarly, certain biological structures, ferroelectric liquid crystals, aluminum oxide clusters and witherite crystallites’ crosssection appear to be elliptical cones. We studied the mean curvature (H) distribution of these elliptic morphological structures with geometric parameter such as eccentricity; e (ratio of semi-minor to semi-major axes) and a measure of how much diagonal section deviates from circularity and height (h) in case of cones. By means of topographical cues, we defined the curvature-curvature autocorrelation function (gk) and applied this notion to mean curvature (H) of circular and elliptical cylinders and cones. The Fourier transform of correlation function, i.e. “curvature factor” is analogous to “structure factor (or Patterson function)” in X-ray and neutron scattering intensity. It elucidates critically important information related to surface curvature fluctuation relevant to shape (geometry), network and phase transformation. The latter is induced by cells under mechanical stress, occurring in many soft systems (polymeric liquid crystals, foams, bubbles) and biological tissues, particularly cell walls of primary and branched vessels bed in microvasculature that distributes blood within tissue during hypertension and migraines. This perspective is useful in a sustained release of angiogenic/vasculogenic factors and relevant for precision medicine and engineered microvessels and tissues in vitro and in vivo extended cellular processes. The quantitative analysis carried out in this work facilitates our understanding of the mechanical mechanisms associated with thrombosis during surgery that typically occur in bent or stretched MVs due to microenvironment such as localized shear stresses and biochemical factors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reconstruction of the interatomic forces from dynamic scanning transmission electron microscopy data

We explore the possibility for reconstruction of the generative physical models describing interactions between atomic units in solids from observational electron microscopy data. In this work, scanning transmission electron microscopy (STEM) is used to observe the dynamic motion of Si atoms at the edge of monolayer graphene under continuous electron beam illumination. The resulting time-lapsed STEM images represent the snapshots of observed chemical states of the system. We use two approaches: potential of mean force calculation using a radial distribution function and a direct fitting of the graphene–Si interatomic pairwise potentials with force matching, to reconstruct the force fields in the materials. These studies lay the foundation for quantitative analysis of materials energetics from STEM data through the sampling of the metastable states in the chemical space of the system.

42 ENGINEERING↗

Effect of hydride vapor phase epitaxy growth conditions on the degree of atomic ordering in GaInP

We report a systematic study of CuPt-type ordering in hydride vapor phase epitaxy (HVPE)-grown Ga 0.5 In 0.5 P. Selected-area electron diffraction reveals ordering in samples grown on (001) GaAs substrates offcut toward (1$\overline{1}$1)B. The ordering is single-variant, occurring only on (1$\overline{1}$1)B planes and not on ($\overline{1}$11)B. Quantitative analysis of the order parameter by high-resolution x-ray diffraction (HRXRD) indicates that ordering increases with deposition temperature in samples grown at 600–700 °C with a constant gas-phase V/III ratio ~3. Ordering increases with V/III ratio in the range of 1.3–6.7 at a constant deposition temperature of 650°C. Photoluminescence measurements correlate the order parameter with Ga0.5In0.5P bandgap contraction, though the contraction is larger than expected based on the magnitude of order parameters measured by HRXRD. A possible reason for this discrepancy is that the photoluminescence emission occurs in the lower bandgap ordered domains, which are small and evenly dispersed throughout the material. We also show that the degree of ordering decreases with growth rate, disappearing at ~60 µm/h. The HVPE-grown material exhibits a generally weaker ordering than organometallic vapor phase epitaxy (OMVPE)-grown material, likely due to the moderate V/III ratios employed, in contrast to the V/III ratios in the 100s typical of OMVPE. However, the tendency for ordering to increase with V/III ratio suggests that the same dimer-induced stress mechanism used to explain the occurrence of ordering in OMVPE-grown material also applies to HVPE. The tendencies for ordering to increase with deposition temperature and decrease with growth rate show that kinetics limit the degree of ordering, also in agreement with OMVPE trends.

74 ATOMIC AND MOLECULAR PHYSICS↗

X-ray multi-probe data acquisition: A novel technique for laser pump x-ray transient absorption spectroscopy

We report the development and implementation of a novel data acquisition (DAQ) technique for synchrotron-based laser pump X-ray Transient Absorption (XTA) spectroscopy, called X-ray Multi-Probe DAQ (XMP DAQ). This technique utilizes high performance analog to digital converters and home-built software to efficiently measure and process the XTA signal from all x-ray pulses between laser excitations. XMP DAQ generates a set of time resolved x-ray absorption spectra at thousands of different pump–probe time delays simultaneously. Two distinct XMP DAQ schemes are deployed to accommodate different synchrotron storage ring filling patterns. Current Integration (CI) DAQ is a quasi-analog technique that implements a fitting procedure to extract the time resolved absorption intensity from the averaged fluorescence detector response. The fitting procedure eliminates issues associated with small drifts in the voltage baseline and greatly enhances the accuracy of the technique. Photon Counting (PC) DAQ is a binary technique that uses a time resolved histogram to calculate the XTA spectrum. While PC DAQ is suited to measure XTA data with closely spaced x-ray pulses (~10 ns) and a low count rate (<1 detected photon/pulse), CI DAQ works best for widely spaced pulses (tens of ns or greater) with a high count rate (>1 detected photon/pulse). XMP DAQ produces a two-dimensional XTA dataset, enabling efficient quantitative analysis of photophysical and photochemical processes from the sub-nanosecond timescale to 100 μs and longer.

47 OTHER INSTRUMENTATION↗

Model fusion with physics-guided machine learning: Projection-based reduced-order modeling

The unprecedented amount of data generated from experiments, field observations, and large-scale numerical simulations at a wide range of spatiotemporal scales has enabled the rapid advancement of data-driven and especially deep learning models in the field of fluid mechanics. Although these methods are proven successful for many applications, there is a grand challenge of improving their generalizability. This is particularly essential when data-driven models are employed within outer-loop applications like optimization. In this work, we put forth a physics-guided machine learning (PGML) framework that leverages the interpretable physics-based model with a deep learning model. Leveraging a concatenated neural network design from multi-modal data sources, the PGML framework is capable of enhancing the generalizability of data-driven models and effectively protects against or inform about the inaccurate predictions resulting from extrapolation. We apply the PGML framework as a novel model fusion approach combining the physics-based Galerkin projection model and long- to short-term memory (LSTM) network for parametric model order reduction of fluid flows. We demonstrate the improved generalizability of the PGML framework against a purely data-driven approach through the injection of physics features into intermediate LSTM layers. Our quantitative analysis shows that the overall model uncertainty can be reduced through the PGML approach, especially for test data coming from a distribution different than the training data. Moreover, we demonstrate that our approach can be used as an inverse diagnostic tool providing a confidence score associated with models and observations. The proposed framework also allows for multi-fidelity computing by making use of low-fidelity models in the online deployment of quantified data-driven models.

42 ENGINEERING↗

Quantifying a partial polyamorphic transition in a cerium-based metallic glass during cooling

Cerium-based metallic glasses are prototype polyamorphous systems with pressure-induced polyamorphic transitions extensively reported. Cooling typically has a similar effect on materials as compression with regard to reducing volume. However, previous studies show dramatically different behavior of Ce-based metallic glasses between cooling and compression, whose origin remains unclear. Here, using in situ low-temperature synchrotron high-energy x-ray diffraction, the structural evolution of a Ce68Al10Cu20Co2 metallic glass is accurately determined and analyzed by a structure factor and a reduced pair distribution function (PDF) during cooling from 298 to 83 K. An unusually large linear thermal expansion coefficient is revealed, which is associated with both continuous but inconsistent structural changes between the two subpeaks of the first atomic shell in terms of average bond lengths and coordination numbers. These phenomena are suggested to be attributed to a gradual 4f electron delocalization of only a minimal amount (∼2.6% at 83 K) of Ce atoms by quantitative analysis of the PDF data. However, a previously expected global polymorphic transition from a low-density amorphous state to a high-density amorphous state with an abrupt volume collapse is not observed. Moreover, electrical resistivity also shows a continuous increase during cooling without any sharp change. It is clarified that cryogenic temperatures could facilitate but are not powerful enough alone to trigger a global polymorphic transition in the Ce68Al10Cu20Co2 metallic glass, suggesting a wide distribution of its local atomic environment.

Chen, Zhi↗

Three-dimensional hot-spot x-ray emission tomography from cryogenic deuterium–tritium direct-drive implosions on OMEGA

A three-dimensional model of the hot-spot x-ray emission has been developed and applied to the study of low-mode drive asymmetries in direct-drive inertial confinement fusion implosions on OMEGA with cryogenic deuterium–tritium targets. Here, the steady-state model assumes an optically thin plasma and the data from four x-ray diagnostics along quasi-orthogonal lines of sight are used to obtain a tomographic reconstruction of the hot spot. A quantitative analysis of the hot-spot shape is achieved by projecting the x-ray emission into the diagnostic planes and comparing this projection to the measurements. The model was validated with radiation-hydrodynamic simulations assuming a mode-2 laser illumination perturbation resulting in an elliptically shaped hot spot, which was accurately reconstructed by the model using synthetic x-ray images. This technique was applied to experimental data from implosions in polar-direct-drive illumination geometry with a deliberate laser-drive asymmetry, and the hot-spot emission was reconstructed using spherical-harmonic modes of up to ℓ = 3. A 10% stronger drive on the equator relative to that on the poles resulted in a prolate-shaped hot spot at stagnation with a large negative A 2,0 coefficient of A 2,0 = –0.47 ± 0.03, directly connecting the modal contribution of the hot-spot shape with the modal contribution in laser-drive asymmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neural network denoising of x-ray images from high-energy-density experiments

Noise is a consistent problem for x-ray transmission images of High-Energy-Density (HED) experiments because it can significantly affect the accuracy of inferring quantitative physical properties from these images. We consider experiments that use x-ray area backlighting to image a thin layer of opaque material within a physics package to observe its hydrodynamic evolution. The spatial variance of the x-ray transmission across the system due to changing opacity serves as an analog for measuring density in this evolving layer. The noise in these images adds nonphysical variations in measured intensity, which can significantly reduce the accuracy of our inferred densities, particularly at small spatial scales. Denoising these images is thus necessary to improve our quantitative analysis, but any denoising method also affects the underlying information in the image. In this paper, we present a method for denoising HED x-ray images via a deep convolutional neural network model with a modified DenseNet architecture. In our denoising framework, we estimate the noise present in the real (data) images of interest and apply the inferred noise distribution to a set of natural images. These synthetic noisy images are then used to train a neural network model to recognize and remove noise of that character. We show that our trained denoiser network significantly reduces the noise in our experimental images while retaining important physical features.

47 OTHER INSTRUMENTATION↗

Incubating advances in integrated photonics with emerging sensing and computational capabilities

As photonic technologies grow in multidimensional aspects, integrated photonics holds a unique position and continuously presents enormous possibilities for research communities. Applications include data centers, environmental monitoring, medical diagnosis, and highly compact communication components, with further possibilities continuously growing. Herein, we review state-of-the-art integrated photonic on-chip sensors that operate in the visible to mid-infrared wavelength region on various material platforms. Among the different materials, architectures, and technologies leading the way for on-chip sensors, we discuss the optical sensing principles that are commonly applied to biochemical and gas sensing. Our focus is on passive optical waveguides, including dispersion-engineered metamaterial-based structures, which are essential for enhancing the interaction between light and analytes in chip-scale sensors. We harness a diverse array of cutting-edge sensing technologies, heralding a revolutionary on-chip sensing paradigm. Our arsenal includes refractive-index-based sensing, plasmonics, and spectroscopy, which forge an unparalleled foundation for innovation and precision. Furthermore, we include a brief discussion of recent trends and computational concepts, incorporating Artificial Intelligence & Machine Learning (AI/ML) and deep learning approaches over the past few years to improve the qualitative and quantitative analysis of sensor measurements.

Jain, Sourabh (ORCID:0000000279923275)↗

Scattering-based structural inversion of soft materials via Kolmogorov–Arnold networks

Small-angle scattering techniques are indispensable tools for probing the structure of soft materials. However, traditional analytical models often face limitations in structural inversion for complex systems, primarily due to the absence of closed-form expressions of scattering functions. To address these challenges, we present a machine learning framework based on the Kolmogorov–Arnold Network (KAN) for directly extracting real-space structural information from scattering spectra in reciprocal space. This model-independent, data-driven approach provides a versatile solution for analyzing intricate configurations in soft matter. By applying the KAN to lyotropic lamellar phases and colloidal suspensions—two representative soft matter systems—we demonstrate its ability to accurately and efficiently resolve structural collectivity and complexity. Here, our findings highlight the transformative potential of machine learning in enhancing the quantitative analysis of soft materials, paving the way for robust structural inversion across diverse systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analytical model of diffuse reflectance spectrum of skin tissue

We have derived simple analytical expressions that enable highly accurate calculation of diffusely reflected light signals of skin in the spectral range from 450 to 800 nm at a distance from the region of delivery of exciting radiation. The expressions, taking into account the dependence of the detected signals on the refractive index, transport scattering coefficient, absorption coefficient and anisotropy factor of the medium, have been obtained in the approximation of a two-layer medium model (epidermis and dermis) for the same parameters of light scattering but different absorption coefficients of layers. Numerical experiments on the retrieval of the skin biophysical parameters from the diffuse reflectance spectra simulated by the Monte Carlo method show that commercially available fibre-optic spectrophotometers with a fixed distance between the radiation source and detector can reliably determine the concentration of bilirubin, oxy- and deoxyhaemoglobin in the dermis tissues and the tissue structure parameter characterising the size of its effective scatterers. We present the examples of quantitative analysis of the experimental data, confirming the correctness of estimates of biophysical parameters of skin using the obtained analytical expressions. (biophotonics)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗