Search NASA⌕ Search

SEARCH · Search NASA

Results for “RELIABLE OPERATION PERFORMANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Develop Wake Mitigation Strategy (CRADA CRD-17-00693 Final Report)

Wind turbines in a wind farm typically operate individually to maximize their own performance and do not take into account information from nearby turbines. In an autonomous wind farm, enabling cooperation to achieve farm-level objectives, turbines will need to use information from nearby turbines to optimize performance, ensure resiliency when other sensors fail, and adapt to changing local conditions. A key element of achieving an autonomous wind farm is to develop algorithms that provide necessary information to ensure reliable, robust, and efficient operation of wind turbines in a wind plant using local sensor information that is already being collected, such as supervisory control and data acquisition (SCADA) data, local meteorological stations, and nearby radars/sodars/lidars. In this work consensus control is applied in a hybrid analysis to data from an existing wind farm to demonstrate the benefit of consensus control.

17 WIND ENERGY↗

Structural Validation at the NWTC Helps Improve Component Design and Increase System Reliability

Since 1990, the National Wind Technology Center (NWTC) at the National Renewable Energy Laboratory (NREL) has validated more than 150 wind turbine blades, as well as blades and components for marine energy devices. Researchers at the NWTC can experimentally validate full-scale and subcomponent articles, conduct data analyses, and provide engineering expertise to optimize design practices. Structural evaluation of turbine blades enables designers, manufacturers, and owner operators t o assess designs and structural performance under specific extreme loading and dynamic conditions. Rigorous structural validation can reveal design and manufacturing problems at an early state of development that lead to improvements in component design and increase system reliability.

17 WIND ENERGY↗

Integral Reactor Containment Condensation Model and Experimental Validation

This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). In the three years of investigation duration, following the original proposal, the planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). A film flow model was developed for the scaling analysis, and the results suggest that the 1/3 scaled test facility covers large portion of laminar film flow, leading to a lower average heat transfer coefficient comparing to the prototypic value. Although it is conservative in reactor safety analysis, the significant reduction of heat transfer coefficient (50%) could under estimate the prototypic condensation heat transfer rate, resulting in inaccurate prediction of the decay heat removal capability. Further investigation is thus needed to quantify the scaling distortion for safety analysis code validation. Experimental investigations were performed in the existing MASLWR test facility at OrST with minor modifications. A total of 13 containment condensation tests were conducted for pressure ranging from 4 to 21 bar with three different static inventories of non-condensable gas. Condensation and heat transfer rates were evaluated employing several methods, notably from measured temperature gradients in the HTP as well as measured condensate formation rates. A detailed mass and energy accounting was used to assess the various measurement methods and to support simplifying assumptions required for the analysis. Condensation heat fluxes and heat transfer coefficients are calculated and presented as a function of pressure to satisfy the objectives of this investigation. The major conclusions for those tests are summarized below: (1) In the steam blow-down tests, the initial condensation heat transfer process involves the heating-up of the containment heat transfer plate. An inverse heat conduction model was developed to capture the rapid transient transfer characteristics, and the analysis method is applicable to SMR safety analysis. (2) The average condensation heat transfer coefficients for different pressure conditions and non-condensable gas mass fractions were obtained from the integral test facility, through the measurements of the heat conduction rate across the containment heat transfer plate, and from the water condensation rates measurement based on the total energy balance equation. 15 (3) The test results using the measured HTP wall temperatures are considerably lower than popular condensation models would predict mainly due to the side wall conduction effects in the existing MASLWR integral test facility. The data revealed the detailed heat transfer characteristics of the model containment, important to the SMR safety analysis and the validation of associated evaluation model. However this approach, unlike separate effect tests, cannot isolate the condensation heat transfer coefficient over the containment wall, and therefore is not suitable for the assessment of the condensation heat transfer coefficient against system pressure and noncondensable gas mass fraction. (4) The average condensation heat transfer coefficients measured from the water condensation rates through energy balance analysis are appropriate, however, with considerable uncertainties due to the heat loss and temperature distribution on the containment wall. With the consideration of the side wall conduction effects, the results indicate that the measured heat transfer coefficients in the tests is about 20% lower than the prediction of Dehbi’s correlation, mainly due to the side wall conduction effects. The investigation also indicates an increase in the condensation heat transfer coefficient at high containment pressure conditions, but the uncertainties invoked with this method appear to be substantial. (5) Non-condensable gas in the tests has little effects on the condensation heat transfer at high elevation measurement ports. It does affect the bottom measurements near the water level position. The results suggest that the heavier non-condensable gas is accumulated in the lower portion of the containment due to stratification in the narrow containment space. The overall effects of the non-condensable gas on the heat transfer process should thus be negligible for tall containments of narrow condensation spaces in most SMR designs. Therefore, the previous correlations with noncondensable gas effects are not appropriate to those small SMR containments due to the very poor mixing of steam and non-condensable gas. The MELCOR simulation results agree with the experimental data reasonably well. However, it is observed that the MELCOR overpredicts the heat flux for all analyzed tests. The MELCOR predicts that the heat fluxes for CCT’s approximately range from 30 to 45 kW/m2 whereas the experimental data (averaged) ranges from about 25 to 40 kW/m2. This may be due to the limited availability of liquid film models included in MELCOR. Also, it is believed that due to complex test geometry, measured temperature gradients across the heat transfer plate may have been underestimated and thus the heat flux had been underestimated. The MELCOR model predicts a film thickness on the order of 100 microns, which agrees very well with film flow model developed in this study for scaling analysis. However, the expected differences in film thicknesses for near vacuum and near atmospheric test conditions are not significant. Further study on the behavior of condensate film is expected to refine the simulation results. Possible refinements include but are not limited to, the followings: CFD simulation focusing on the liquid film behavior and benchmarking with experimental analyses for simpler geometries. 16 1 INTRODUCTION This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). The experimental results are employed to validate the containment condensation model in reactor containment system safety analysis code for integral SMRs. Such a containment condensation model is important to demonstrate the adequate cooling. In the three years of investigation, following the original proposal, the following planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). The results are applicable to integral Small Modular Reactor (SMR) designs, including NuScale, mPower, Westinghouse SMR, Holtec-160 and other integral reactors with small containments of relatively high pressures under accidental conditions. Testing has been conducted at the OrSU laboratory in the existing MASLWR (Multi-Application Small Light Water Reactor) integral test facility sponsored by the US Department of Energy. Its highpressure stainless steel containment model (~2 MPa) is scaled to the NuScale SMR currently under development at NuScale Power, Inc.. Minor modifications to the model containment have been made to control the non-condensable gas fraction and to utilize the secondary loop stable steam flow for condensation testing. UW-Madison has developed a containment condensation model, which leveraged previous validated containment heat transfer work carried out at UW-Madison, and extended the range of applicability of the model to integral SMR designs that utilize containment vessels of high heat transfer efficiencies. In this final report, the research background and literature survey are presented in Chapter 2 and 3, respectively. The test facility description and modifications are summarized in Chapter 4, and the scaling analysis is introduced in Chapter 5. The tests description, procedures, and data analysis are presented in Chapter 6, while the numerical modeling is presented in Chapter 7, followed by a conclusion section in Chapter 8.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Solid Oxide Fuel Cell Technology Stationary Power Application Project

The objectives of this program were to: (1) Develop a reliable, cost-effective, and production-friendly technique to apply the power-enhancing layer at the interface of the air electrode and electrolyte of the Siemens SOFC; (2) Design, build, install, and operate in the field two 5 kWe SOFC systems fabricated with the state-of-the-art cylindrical, tubular cell and bundle technology and incorporating advanced module design features. Siemens successfully demonstrated, first in a number of single cell tests and subsequently in a 48-cell bundle test, a significant power enhancement by employing a power-enhancing composite interlayer at the interface between the air electrode and electrolyte. While successful from a cell power enhancement perspective, the interlayer application process was not suitable for mass manufacturing. The application process was of inconsistent quality, labor intensive, and did not have an acceptable yield. This program evaluated the technical feasibility of four interlayer application techniques. The candidate techniques were selected based on their potential to achieve the technical requirements of the interlayer, to minimize costs (both labor and material), and suitably for large-scale manufacturing. Preliminary screening, utilizing lessons learned in manufacturing tubular cells, narrowed the candidate processes to two, ink-roller coating (IRC) and dip coating (DC). Prototype fixtures were successfully built and utilized to further evaluate the two candidate processes for applying the interlayer to the high power density Delta8 cell geometry. The electrical performance of interlayer cells manufactured via the candidate processes was validated. Dip coating was eventually selected as the application technique of choice for applying the interlayer to the high power Delta8 cell. The technical readiness of the DC process and product quality was successfully and repeatedly demonstrated, and its throughput and cost are amenable to large scale manufacturing. Two 5 kWe-class SOFC power systems were built and installed for the purpose of testing and evaluating state-of-the-art tubular cell and bundle technologies, advanced generator and module design features, balance-of-plant components, and cost reduction measures. Installed at the Phipps Conservatory and Botanical Gardens, a system operated for more than 17,500 hrs, delivering electrical power to the on-site grid and thermal energy in form of hot water for onsite utilization. Operation was typically autonomous, requiring minimal operator intervention, and achieved an overall availability of greater than 85%. Outages were primarily due to an unstable local grid, two weather related outages were experienced, and very few reliability issues were encountered despite harsh operating conditions. No repairs to the stack, module, or balance-of-plant were required. A second system was designed, built, delivered, and installed at a Siemens facility in Charlotte, North Carolina. Operational issues associated with the balance-of-plant were encountered during startup and prevented the system from operating.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solid-State Thyratron Replacement. Final Report

Under this SBIR, DTI developed a solid-state switch as an alternative to legacy thyratron equipment. Our Phase II objective was to make a solid-state thyratron replacement that would provide equivalent or better performance, much higher reliability (at least a 20 year lifetime, compared to a thyratron’s two-year lifetime) and would sell for ~3x the cost of a thyratron, or less than $40k. We were successful in building a solid-state switch which could reliably function as a thyratron replacement. The unit was designed to directly replace the thyratrons currently being used at SLAC’s Linac Coherent Light Source (LCLS), and was built in a tank that was small enough to fit into the existing thyratron cabinet, providing a true form-fit-function replacement path. We tested the switch at the full operating specifications: 48 kV, 6.3 kA, and 1 µs risetime. We also demonstrated a peak-to-peak pulse jitter of 1.5 ns, which is five times shorter than is typical for thyratrons. This lower jitter would improve the performance of the LCLS beam. The predicted reliability is more than 80 years, which is 40 times greater than a thyratron.

47 OTHER INSTRUMENTATION↗

Hydraulic Hybrid Parcel Delivery Truck Deployment, Testing & Demonstration

Although hydraulic hybrid systems have shown promise over the last few years, commercial deployment of these systems has primarily been limited to Class 8 refuse trucks. In 2005, the Hybrid Truck Users Forum initiated the Parcel Delivery Working Group including the largest parcel delivery fleets in North America. The goal of the working group was to evaluate and accelerate commercialization of hydraulic hybrid technology for parcel delivery vehicles. FedEx Ground, Purolator and United Parcel Service (UPS) took delivery of the world’s first commercially available hydraulic hybrid parcel delivery trucks in early 2012. The vehicle chassis includes a Parker Hannifin hydraulic hybrid drive system, integrated and assembled by Freightliner Custom Chassis Corp., with a body installed by Morgan Olson. With funding from the U.S. Department of Energy, CALSTART and its project partners assessed the performance, reliability, maintainability and fleet acceptance of three pre-production Class 6 hydraulic hybrid parcel delivery vehicles using information and data from in-use data collection and on-road testing. This document reports on the deployment of these vehicles operated by FedEx Ground, Purolator and UPS. The results presented provide a comprehensive overview of the performance of commercial hydraulic hybrid vehicles in parcel delivery applications. This project also informs fleets and manufacturers on the overall performance of hydraulic hybrid vehicles, provides insights on how the technology can be both improved and more effectively used. The key findings and recommendations of this project fall into four major categories: Performance, Fleet deployment, Maintenance, and Business case. Hydraulic hybrid technology is relatively new to the market, as commercial vehicles have been introduced only in the past few years in refuse and parcel delivery applications. Successful demonstration could pave the way for additional purchases of hydraulic hybrid vehicles throughout the trucking industry. By providing unbiased, third-party assessment of this “hybrid without batteries” technology, this report offers relevant, timely and valuable information to the industry.

33 ADVANCED PROPULSION SYSTEMS↗

Ribbons Affect Movement of Cracked Solar Cells [Poster]

Cracking of crystalline silicon photovoltaic cells remains a challenging topic in accurately assessing the long-term reliability and performance of affected modules. Cells can be damaged in every stage throughout the lifetime of a photovoltaic module, ranging from manufacturing, transportation, and installation to operation. Initially, the metallization can be able to bridge the gap of fractured cells and keep individual cell fragments electrically connected. However, photovoltaic modules and cells experience thermo-mechanical stresses during operation from temperature changes and pressure cycles of wind and snow loads. This causes the cell fragments to move, which, in turn, can lead to the wear out of the metallization and, consequently, to power loss or a safety hazard. The rate at which this degradation mechanism proceeds is currently unknown. Hence, in this work, we quantify the cell fragment movement of polycrystalline and monocrystalline mini-modules. By using digital image correlation, we were able to extract the normal crack opening and tangential sliding distances of adjacent cell fragments during heating of the mini-modules. Those distances are essential to develop wear-out models for the metallization and determine the rate of the degradation mechanism. We found that the interconnect technology has a significant impact on the direction and quantity of the cell fragment movements.

14 SOLAR ENERGY↗

Composite Overwrapped Pressure Vessels (COPV) Stress Rupture Test

One of the major concerns for the aging Space Shuttle fleet is the stress rupture life of composite overwrapped pressure vessels (COPVs). Stress rupture life of a COPV has been defined as the minimum time during which the composite maintains structural integrity considering the combined effects of stress levels and time. To assist in the evaluation of the aging COPVs in the Orbiter fleet an analytical reliability model was developed. The actual data used to construct this model was from testing of COPVs constructed of similar, but not exactly same materials and pressure cycles as used on Orbiter vessels. Since no actual Orbiter COPV stress rupture data exists the Space Shuttle Program decided to run a stress rupture test to compare to model predictions. Due to availability of spares, the testing was unfortunately limited to one 40" vessel. The stress rupture test was performed at maximum operating pressure at an elevated temperature to accelerate aging. The test was performed in two phases. The first phase, 130 F, a moderately accelerated test designed to achieve the midpoint of the model predicted point reliability. The more aggressive second phase, performed at 160 F was designed to determine if the test article will exceed the 95% confidence interval of the model. This paper will discuss the results of this test, it's implications and possible follow-on testing.

Russell, Richard↗

Small Unmanned Aerial System (UAS) Flight Testing of Enabling Vehicle Technologies for the UAS Traffic Management Project

Small unmanned aerial systems (sUAS) have been studied and results indicate that there is a large array of highly-beneficial applications. These applications are too numerous to list, but include search and rescue, fire spotting, precision agriculture, etc. to name a few. Typically sUAS vehicles weigh less than 55 pounds and will be performing flight operations in the presence of manned aircraft and other sUAS. Certain sUAS applications, such as package delivery, will include operations in the close proximity of the general public. The full benefit from sUAS is contingent upon the resolution of several technological areas to enable free and widespread use of these vehicles. Technological areas in question include, but are not limited to: autonomous sense and avoid and deconfliction of sUAS from other sUAS and manned aircraft, communications and interfaces between the vehicle and human operators, and high-reliability autonomous systems. The NASA UAS Traffic Management (UTM) project is endeavoring to develop a traffic management system and concept of operations for these types of vehicles. An extensive sUAS flight test effort was performed to partially address vehicle-related technological areas and to shape an understanding of future developmental and test efforts for vehicles intended to use the UTM traffic management system. The flight testing described herein had the following objectives: 1) Install and test Dedicated Short Range Communications (DSRC) systems developed for the automotive industry for potential sense and avoid sUAS applications; 2) Evaluate the use of cellular 4G systems to provide vehicle control; 3) Obtain high-resolution video imagery in support of image-based optical detection sense and avoid systems; 4) Acquire data in fixed-wing flight to support validation and maturation of an autonomous range containment system known as Safeguard in fixed-wing flight. A total of 53 flights were performed over 12 operational days at Beaver Dam Airpark in Elberon, VA. This work was sponsored by the UTM project that is part of the Aviation Operations and Safety Program (AOSP) at NASA.

Glaab, Louis J.↗

A Low-Cost Soft-Switched DC/DC Converter for Solid-Oxide Fuel Cells

A highly efficient DC to DC converter has been developed for low-voltage high-current solid oxide fuel cells. The newly developed 'V6' converter resembles what has been done in internal combustion engine that split into multiple cylinders to increase the output capacity without having to increase individual cell size and to smooth out the torque with interleaving operation. The development was started with topology overview to ensure that all the DC to DC converter circuits were included in the study. Efficiency models for different circuit topologies were established, and computer simulations were performed to determine the best candidate converter circuit. Through design optimization including topology selection, device selection, magnetic component design, thermal design, and digital controller design, a bench prototype rated 5-kW, with 20 to 50V input and 200/400V output was fabricated and tested. Efficiency goal of 97% was proven achievable through hardware experiment. This DC to DC converter was then modified in the later stage to converter 35 to 63 V input and 13.8 V output for automotive charging applications. The complete prototype was tested at Delphi with their solid oxide fuel cell test stand to verify the performance of the modified DC to DC converter. The output was tested up to 3-kW level, and the efficiency exceeded 97.5%. Multiple-phase interleaving operation design was proved to be reliable and ripple free at the output, which is desirable for the battery charging. Overall this is a very successful collaboration project between the SECA Core Technology Team and Industrial Team.

25 ENERGY STORAGE↗

Balancing Needs Assessment Using Advanced Probabilistic Forecasts

This paper presents a comprehensive approach to predict Balancing Authority (BA) regulation and load following requirements in order to improve BA control performance. In this paper the Pacific Northwest National Laboratory’s (PNNL) “ramp and uncertainty prediction tool (RUT) and day-ahead regulation prediction (DARP) tool” were upgraded to incorporate advanced probabilistic forecast information provided by AWS Truepower. The proposed methodology has been tested and validated using actual California Independent System Operator (CAISO) data. Simulation confirmed that integration probabilistic forecast information can reduce the predicted regulation range by about 12-31%. This means that BAs can procure fewer balancing resources without compromising their reliability and control performance requirements.

Regulation, Solar Generation, Wind Generation, Con↗

Oxygen and relative humidity monitoring with films tailored for enhanced photoluminescence

In this study, approaches to generate porous or doped sensing films, which significantly enhance the photoluminescence (PL) of oxygen optical sensors, and thus improve the signal-to-noise (S/N) ratio, are presented. Tailored films, which enable monitoring the relative humidity (RH) as well, are also presented. Effective porous structures, in which the O 2 -sensitive dye Pt octaethylporphyrin (PtOEP) or the Pd analog PdOEP was embedded, were realized by first generating blend films of polyethylene glycol (PEG) with polystyrene (PS) or with ethyl cellulose (EC), and then immersing the dried films in water to remove the water-soluble PEG. This approach creates pores (voids) in the sensing films. The dielectric contrast between the films’ constituents and the voids increases photon scattering, which in turn increases the optical path of the excitation light within the film, and hence light absorption by the dye, and its PL. Optimized sensing films with a PEG:PS ratio of 1:4 (PEG’s molecular weight M w ~8000) led to ~4.4× enhancement in the PL (in comparison to PS films). Lower M w ~200 PEG with a PEG:EC ratio of 1:1 led to a PL enhancement of ~4.7×. Film-dependent PL enhancements were observed at all oxygen concentrations. The strong PL enhancement enables (i) using lower dye (luminophore) concentrations, (ii) reducing power consumption and enhancing the sensor’s operational lifetime when using organic light emitting diodes (OLEDs) as excitation sources, (iii) improving performance when using compact photodetectors with no internal gain, and (iv) reliably extending the dynamic range.

47 OTHER INSTRUMENTATION↗

Out-of-distribution detection with non-parametric density estimation for models predicting processing history of uranium ore concentrates

The rapid advancement in machine learning (ML) and computer vision (CV) coincides with the growth of interest in deploying these ML/CV models in numerous fields from medicine to social science. Similar to those areas, we have witnessed a great number of works in materials science employing ML/CV models – neural networks in particular – in their studies in recent years. These models have proven to obtain accurate performance in various tasks. However, these models struggle to attain a similar performance when encountering test samples coming from a distribution that is different from the training set. More importantly, they fail without providing any warning to the users. Therefore, we propose a framework for detecting out-of-distribution (OOD) samples to alert users when a human intervention might be necessary in this work. Specifically, we explore the use of a non-parametric density estimation method to detect OOD samples. Here, we assess OOD detection capability of the proposed framework on ML models developed for categorizing precipitation routes of U 3 O 8 when encountering OOD datasets that contain samples (1) undergone different imaging acquisition process, (2) undergone different material synthesis process, and (3) different materials than ID set. Through those experiments, we achieve an average area under the receiver operating characteristic (AUROC) of at least 91% on average in detecting OOD samples. With minimal overhead cost and superior performance, the proposed framework enables a reliable and safe system when deploying in real-world scenarios.

Convolutional neural networks↗

CyPhyR: a cyber‐physical analysis tool for measuring and enabling resiliency in microgrids

This study presents a tool to study the cyber‐physical resiliency (CyPhyR) of critical energy infrastructure system, in particular the effect of cyber attacks on the microgrid's resiliency. The developed tool enables measuring resiliency using data from cyber and physical systems and suggests control decisions for resilient planning and operation of the microgrid. The microgrid resiliency is formulated based on graph theory based indices and cyber‐power system characteristics. A Common Vulnerability Scoring System based metric called the Cyber Asset Impact Potential is developed and used in the planning phase, and another metric, Cyber Impact Severity is introduced to study the system performance in the operational phase. The information from these two phases is provided to the operator to make informed and proactive decisions to ensure the resilient operation of the microgrid. The performance of the developed tool has been tested using comprehensive real‐time cyber‐power testbed for a Consortium for Electric Reliability Technology Solutions microgrid test system.

Venkataramanan, Venkatesh↗

LONG-TERM CALIBRATION STABILITY OF A RADIO ASTRONOMICAL PHASED ARRAY FEED

There are many challenges associated with the implementation of a phased array feed for radio astronomy applications. Among these is the need to have an adequate set of calibration measurements so that reliable beamformers can be computed. Changes in the operating environment and temporal gain drift in the electronics contribute to calibration drift, which affects the beamformer performance. We will show that calibration measurements are relatively stable over a 5 day period and may remain so for up to 70 days or longer. We have incorporated the use of a calibration update system that has the potential to refresh a set of old calibrators, specifically correcting for electronic gain drift. However, the long-term variations that are present with fresh, current calibrators are greater than the degradation due to using an old calibration set, suggesting that, at this time, there is not a need for sophisticated calibration update systems or algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of a Disturbance Event with Inverter-Based Resources Using EMT Simulations

Increasing penetration of inverter-based resources (IBRs) necessitates newer methods of planning and analysis of disturbances. The existing phasor-domain transient stability (TS) analysis may not capture the dynamics of IBRs during fault events. Here, in this paper, electromagnetic transient (EMT) simulations using high-fidelity detailed model of power grid and one of the affected photovoltaic (PV) plants during the Angeles Forest disturbance in 2018 are performed. In these simulations, the processes to develop EMT models of power grid from traditional phasor-domain TS data and PV plant from collected data are described. Thereafter, using these simulations, the response of the PV plant during the fault event in 2018 is replicated and a sensitivity analysis is performed. The sensitivity analysis consists of making changes to the components within the PV plant and in the power grid to evaluate the impact they have on the response observed by the PV plant during the fault event. This analysis provides an understanding of the components that impact the operation of a PV plant during fault events and provide guidance to system planners on the studies that need to be performed to maintain a reliable power grid as new IBR plants are integrated.

42 ENGINEERING↗

Advanced Micro Combined Heat and Power Device

U.S. buildings account for approximately 40% of total U.S. energy consumption and 75% of electricity use, emphasizing the need for efficient, resilient, and secure energy solutions. Micro-combined heat and power (micro-CHP) systems provide an effective approach by simultaneously generating electricity and recovering waste heat for thermal use. However, current commercial micro-CHPs face challenges in achieving higher efficiency, lower emissions, and reduced cost. To address these limitations, a novel micro-CHP prototype powered by a unique opposed-piston four-stroke (OP4S) engine was developed. The OP4S features a simplified, low-cost design with reduced heat losses and dual-piston operation that enables higher thermal efficiency. Experimental results demonstrated up to 35.2% AC electrical efficiency under lean combustion, surpassing the best-performing ICE-based micro-CHPs reported publicly. In addition, the micro-CHP enables a total CHP efficiency exceeding 93%. The prototype operates reliably for over 600 hours, providing flexible and efficient thermal and electrical outputs. This novel OP4S-based micro-CHP offers a resilient, low-cost, and energy-efficient solution suitable for residential, light commercial, and remote community applications across diverse climate zones.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Fundamental Studies and Development of III-N Visible LEDs for High-Power Solid-State Lighting Applications

The goal of this program is to understand in a fundamental way the impact of strain, defects, polarization, and Stokes loss in relation to unique device structures upon the internal quantum efficiency (IQE) and efficiency droop (ED) of III-nitride (III-N) light-emitting diodes (LEDs) and to employ this understanding in the design and growth of high-efficiency LEDs capable of highly-reliable, high-current, high-power operation. This knowledge will be the basis for our advanced device epitaxial designs that lead to improved device performance. The primary approach we will employ is to exploit new scientific and engineering knowledge generated through the application of a set of unique advanced growth and characterization tools to develop new concepts in strain-, polarization-, and carrier dynamics-engineered and low-defect materials and device designs having reduced dislocations and improved carrier collection followed by efficient photon generation. We studied the effects of crystalline defect, polarizations, hole transport, electron-spillover, electron blocking layer, underlying layer below the multiplequantum- well active region, and developed high-efficiency and efficiency-droop-mitigated blue LEDs with a new LED epitaxial structure. We believe new LEDs developed in this program will make a breakthrough in the development of high-efficiency high-power visible III-N LEDs from violet to green spectral region.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗