Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ranking methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Feasibility Study of Non-Destructive Techniques to Measure Corrosion in SAVY Containers

Stainless Steel SAVY containers are used to transport and store nuclear material. They are prone to interior corrosion in the presence of certain chemicals and a low-oxygen environment. SAVY containers also have relatively thin walls to reduce their weight, making their structural integrity more vulnerable to the effects of corrosion. A nondestructive evaluation system that finds and monitors corrosion within containers in use would improve safety conditions and preclude hazards. Non-destructive testing can determine whether oxidation or corrosion is occurring inside the SAVY containers, and there are a variety of non-destructive testing methods that may be viable. The feasibility study described will objectively decide which method best fits the requirements of the facility and the problem. To improve efficiency, the containers cannot be opened during the non-destructive examination. The chosen technique should also be user-friendly and relatively quick to apply. It must also meet facility requirements regarding wireless technology and maintenance. A feasibility study is an objective search for a new technology or product to solve a particular problem. First, the design, technical, and facility feasibility requirements are chosen and ranked in order of importance. Then each technology considered is given a score based upon a standard ranking system. The technology with the highest total score is deemed the best fit for a certain application.

42 ENGINEERING↗

The influence of various test plans on mission reliability

Methods have been developed for the evaluation of cost effective vibroacoustic test plans for Shuttle Spacelab payloads. The shock and vibration environments of components have been statistically represented, and statistical decision theory has been used to evaluate the cost effectiveness of five basic test plans with structural test options for two of the plans. Component, subassembly, and payload testing have been performed for each plan along with calculations of optimum test levels and expected costs. The tests have been ranked according to both minimizing expected project costs and vibroacoustic reliability. It was found that optimum costs may vary up to $6 million with the lowest plan eliminating component testing and maintaining flight vibration reliability via subassembly tests at high acoustic levels.

Stahle, C. V.↗

A machine learning method of modern urban building energy modeling: A case study of Chicago

Urban-scale building energy modeling is vital for urban planning. However, it can be challenging to assimilate reliable non-geometry building data for urban-scale modeling without extensive investment. Here, this study introduces a novel approach to developing modern urban-scale building energy stock data using geographic information systems and machine learning algorithms without necessarily requiring pre-supplied non-geometric metadata. The proposed framework integrates building footprint and height data to estimate gross floor areas, and matches each building to a pool of candidate records from ComStock or ResStock—filtered to the same county and ranked by geometric similarity—demonstrate a proof-of-concept case study in Chicago for predicting energy use intensity (EUI) using scalable datasets. The model achieved a mean bias error (MBE) of 0.08 kWh/m² and root mean square error (RMSE) of 14.84 kWh/m² under full metadata input for EUI prediction. With only location inputs, the model captured 69.2 % of EUI within predicted ranges. These results demonstrate the model’s potential to support early-stage urban planning, identify candidates for energy-efficient retrofits. By removing the dependency on detailed pre-surveys or extensive building metadata, the approach overcomes a key barrier in traditional urban-scale building energy modeling, illustrating a pathway toward broader and more cost-effective application, though further multi-city validation and improved treatment of pre-1925 buildings are needed.

Energy Use Intensity↗

Incorporating single-side sparing in models for predicting parotid dose sparing in head and neck IMRT

Purpose: Sparing of single-side parotid gland is a common practice in head-and-neck (HN) intensity modulated radiation therapy (IMRT) planning. It is a special case of dose sparing tradeoff between different organs-at-risk. The authors describe an improved mathematical model for predicting achievable dose sparing in parotid glands in HN IMRT planning that incorporates single-side sparing considerations based on patient anatomy and learning from prior plan data. Methods: Among 68 HN cases analyzed retrospectively, 35 cases had physician prescribed single-side parotid sparing preferences. The single-side sparing model was trained with cases which had single-side sparing preferences, while the standard model was trained with the remainder of cases. A receiver operating characteristics (ROC) analysis was performed to determine the best criterion that separates the two case groups using the physician's single-side sparing prescription as ground truth. The final predictive model (combined model) takes into account the single-side sparing by switching between the standard and single-side sparing models according to the single-side sparing criterion. The models were tested with 20 additional cases. The significance of the improvement of prediction accuracy by the combined model over the standard model was evaluated using the Wilcoxon rank-sum test. Results: Using the ROC analysis, the best single-side sparing criterion is (1) the predicted median dose of one parotid is higher than 24 Gy; and (2) that of the other is higher than 7 Gy. This criterion gives a true positive rate of 0.82 and a false positive rate of 0.19, respectively. For the bilateral sparing cases, the combined and the standard models performed equally well, with the median of the prediction errors for parotid median dose being 0.34 Gy by both models (p = 0.81). For the single-side sparing cases, the standard model overestimates the median dose by 7.8 Gy on average, while the predictions by the combined model differ from actual values by only 2.2 Gy (p = 0.005). Similarly, the sum of residues between the modeled and the actual plan DVHs is the same for the bilateral sparing cases by both models (p = 0.67), while the standard model predicts significantly higher DVHs than the combined model for the single-side sparing cases (p = 0.01). Conclusions: The combined model for predicting parotid sparing that takes into account single-side sparing improves the prediction accuracy over the previous model.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessing health impacts in complex eco-epidemiological settings in the humid tropics: Advancing tools and methods

In the developing world, large-scale projects in the extractive industry and natural resources sectors are often controversial and associated with long-term adverse health consequences to local communities. In many industrialised countries, health impact assessment (HIA) has been institutionalized for the mitigation of anticipated negative health effects while enhancing the benefits of projects, programmes and policies. However, in developing country settings, relatively few HIAs have been performed. Hence, more HIAs with a focus on low- and middle-income countries are needed to advance and refine tools and methods for impact assessment and subsequent mitigation measures. We present a promising HIA approach, developed within the frame of a large gold-mining project in the Democratic Republic of the Congo. The articulation of environmental health areas, the spatial delineation of potentially affected communities and the use of a diversity of sources to obtain quality baseline health data are utilized for risk profiling. We demonstrate how these tools and data are fed into a risk analysis matrix, which facilitates ranking of potential health impacts for subsequent prioritization of mitigation strategies. The outcomes encapsulate a multitude of environmental and health determinants in a systematic manner, and will assist decision-makers in the development of mitigation measures that minimize potential adverse health effects and enhance positive ones.

54 ENVIRONMENTAL SCIENCES↗

High-Density and Very-Low-Density Lipoprotein Have Opposing Roles in Regulating Tumor-Initiating Cells and Sensitivity to Radiation in Inflammatory Breast Cancer

Purpose: We previously demonstrated that cholesterol-lowering agents regulate radiation sensitivity of inflammatory breast cancer (IBC) cell lines in vitro and are associated with less radiation resistance among IBC patients who undergo postmastectomy radiation. We hypothesized that decreasing IBC cellular cholesterol induced by treatment with lipoproteins would increase radiation sensitivity. Here, we examined the impact of specific transporters of cholesterol (ie lipoproteins) on the responses of IBC cells to self-renewal and to radiation in vitro and on clinical outcomes in IBC patients. Methods and Materials: Two patient-derived IBC cell lines, SUM 149 and KPL4, were incubated with low-density lipoproteins (LDL), very-low-density lipoproteins (VLDL), or high-density lipoproteins (HDL) for 24 hours prior to irradiation (0-6 Gy) and mammosphere formation assay. Cholesterol panels were examined in a cohort of patients with primary IBC diagnosed between 1995 and 2011 at MD Anderson Cancer Center. Lipoprotein levels were then correlated to patient outcome, using the log rank statistical model, and examined in multivariate analysis using Cox regression. Results: VLDL increased and HDL decreased mammosphere formation compared to untreated SUM 149 and KPL4 cells. Survival curves showed enhancement of survival in both of the IBC cell lines when pretreated with VLDL and, conversely, radiation sensitization in all cell lines when pretreated with HDL. In IBC patients, higher VLDL values (>30 mg/dL) predicted a lower 5-year overall survival rate than normal values (hazard ratio [HR] = 1.9 [95% confidence interval [CI]: 1.05-3.45], P=.035). Lower-than-normal patient HDL values (<60 mg/dL) predicted a lower 5-year overall survival rate than values higher than 60 mg/dL (HR = 3.21 [95% CI: 1.25-8.27], P=.015). Conclusions: This study discovered a relationship among the plasma levels of lipoproteins, overall patient response, and radiation resistance in IBC patients and IBC patient-derived cell lines. A more expansive study is needed to verify these observations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postmastectomy Radiation Therapy Is Associated With Improved Survival in Node-Positive Male Breast Cancer: A Population Analysis

Purpose: Because of its rarity, there are no randomized trials investigating postmastectomy radiation therapy (PMRT) in male breast cancer. This study retrospectively examines the impact of PMRT in male breast cancer patients in the National Cancer Institute's Surveillance, Epidemiology, and End Results (SEER) database. Methods and Materials: The SEER database 8.3.2 was queried for men ages 20+ with a diagnosis of localized or regional nonmetastatic invasive ductal/lobular carcinoma from 1998 to 2013. Included patients were treated by modified radical mastectomy (MRM), with or without adjuvant external beam radiation. Univariate and multivariate analyses evaluated predictors for PMRT use after MRM. Kaplan-Meier overall survival (OS) curves of the entire cohort and a case-matched cohort were calculated and compared by the log-rank test. Cox regression was used for multivariate survival analyses. Results: A total of 1933 patients were included in the unmatched cohort. There was no difference in 5-year OS between those who received PMRT and those who did not (78% vs 77%, respectively, P=.371); however, in the case-matched analysis, PMRT was associated with improved OS at 5 years (83% vs 54%, P<.001). On subset analysis of the unmatched cohort, PMRT was associated with improved OS in men with 1 to 3 positive nodes (5-year OS 79% vs 72% P=.05) and those with 4+ positive nodes (5-year OS 73% vs 53% P<.001). On multivariate analysis of the unmatched cohort, independent predictors for improved OS were use of PMRT: HR=0.551 (0.412-0.737) and estrogen receptor–positive disease: HR=0.577 (0.339-0.983). Predictors for a survival detriment were higher grade 3/4: HR=1.825 (1.105-3.015), larger tumor T2: HR=1.783 (1.357-2.342), T3/T4: HR=2.683 (1.809-3.978), higher N-stage: N1 HR=1.574 (1.184-2.091), N2/N3: HR=2.328 (1.684-3.218), black race: HR=1.689 (1.222-2.336), and older age 81+: HR=4.164 (1.497-11.582). Conclusions: There may be a survival benefit with the addition of PMRT for male breast cancer with node-positive disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neutron diffraction discriminates between models for the nanoarchitecture of graphene sheets in glassy carbon

Glassy carbon is a chemically inert, biocompatible, disordered material with the graphene sheet as its basic building block. Structural characterisation techniques have so far been unable to provide definitive distinction between the many proposed models for its structure. Computer based simulation methods have made a step forward by predicting structure from interaction potentials, but the results are sensitive to the choice of the potential. Here we use the white neutron beam of the Spallation Neutron Source at Oak Ridge National Laboratory coupled with the SNAP time-of-flight diffractometer to sample the reciprocal space of glassy carbon and calculate accurate radial distribution functions. From the radial distribution information, we determine graphene sheet dimensions, registration, curvature, and assess defect content to rank the proposed structures in terms of their agreement with experimental data. In this work, we find that the recent models derived from empirical potentials give the best agreement.

36 MATERIALS SCIENCE↗

A long short-term memory embedding for hybrid uplifted reduced order models

In this paper, we introduce an uplifted reduced order modeling (UROM) approach through the integration of standard projection based methods with long short-term memory (LSTM) embedding. Our approach has three modeling layers or components. In the first layer, we utilize an intrusive projection approach to model dynamics represented by the largest modes. The second layer consists of an LSTM model to account for residuals beyond this truncation. This closure layer refers to the process of including the residual effect of the discarded modes into the dynamics of the largest scales. However, the feasibility of generating a low rank approximation tails off for higher Kolmogorov n -width systems due to the underlying nonlinear processes. The third uplifting layer, called super-resolution, addresses this limited representation issue by expanding the span into a larger number of modes utilizing the versatility of LSTM. Therefore, our model integrates a physics-based projection model with a memory embedded LSTM closure and an LSTM based super-resolution model. In several applications, we exploit the use of Grassmann manifold to construct UROM for unseen conditions. We performed numerical experiments by using the Burgers and Navier-Stokes equations with quadratic nonlinearity. Finally, our results show robustness of the proposed approach in building reduced order models for parameterized systems and confirm the improved trade-off between accuracy and efficiency.

42 ENGINEERING↗

A WELL-POSED KELVIN-HELMHOLTZ INSTABILITY TEST AND COMPARISON

Recently, there has been a significant level of discussion of the correct treatment of Kelvin-Helmholtz instability (KHI) in the astrophysical community. This discussion relies largely on how the KHI test is posed and analyzed. We pose a stringent test of the initial growth of the instability. The goal is to provide a rigorous methodology for verifying a code on two-dimensional KHI. We ran the problem in the Pencil Code, Athena, Enzo, NDSPMHD, and Phurbas. A strict comparison, judgment, or ranking, between codes is beyond the scope of this work, though this work provides the mathematical framework needed for such a study. Nonetheless, how the test is posed circumvents the issues raised by tests starting from a sharp contact discontinuity yet it still shows the poor performance of smoothed particle hydrodynamics (SPH). We then comment on the connection between this behavior to the underlying lack of zeroth-order consistency in SPH interpolation. We comment on the tendency of some methods, particularly those with very low numerical diffusion, to produce secondary Kelvin-Helmholtz billows on similar tests. Though the lack of a fixed, physical diffusive scale in the Euler equations lies at the root of the issue, we suggest that in some methods an extra diffusion operator should be used to damp the growth of instabilities arising from grid noise. This statement applies particularly to moving-mesh tessellation codes, but also to fixed-grid Godunov schemes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Dimensionally Aligned Signal Projection for Classification of Unintended Radiated Emissions

Characterization of unintended radiated emissions (URE) from electronic devices plays an important role in many research areas from electromagnetic interference to nonintrusive load monitoring to information system security. URE can provide insights for applications ranging from load disaggregation and energy efficiency to condition-based maintenance of equipment-based upon detected fault conditions. URE characterization often requires subject matter expertise to tailor transforms and feature extractors for the specific electrical devices of interest. We present a novel approach, named dimensionally aligned signal projection (DASP), for projecting aligned signal characteristics that are inherent to the physical implementation of many commercial electronic devices. These projections minimize the need for an intimate understanding of the underlying physical circuitry and significantly reduce the number of features required for signal classification. We present three possible DASP algorithms that leverage frequency harmonics, modulation alignments, and frequency peak spacings, along with a two-dimensional image manipulation method for statistical feature extraction. To demonstrate the ability of DASP to generate relevant features from URE, we measured the conducted URE from 14 residential electronic devices using a 2 MS/s collection system. Furthermore, a linear discriminant analysis classifier was trained using DASP generated features and was blind tested resulting in a greater than 90% classification accuracy for each of the DASP algorithms and an accuracy of 99.1% when DASP features are used in combination. Furthermore, we show that a rank reduced feature set of the combined DASP algorithms provides a 98.9% classification accuracy with only three features and outperforms a set of spectral features in terms of general classification as well as applicability across a broad number of devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prone Positioning Causes the Heart To Be Displaced Anteriorly Within the Thorax: Implications for Breast Cancer Treatment

Introduction: Prone positioning has been suggested as an alternative to the conventional supine position for patients receiving breast radiotherapy, but few data exist on how this may alter heart location. We herein quantitatively compare the intrathoracic location of the heart in the prone and supine positions in patients treated for breast cancer. Methods and Materials: In 16 patients treated with tangent photons for breast cancer, the computed tomography planning images (obtained in the supine position) and diagnostic magnetic resonance images (obtained in the prone position) were studied. For each case, the distance between the anterior pericardium and the anterior chest wall was measured at nine specific points; three points at each of three axial levels. The differences in the measurements between the prone and supine positions were compared with the Wilcoxon signed-rank test. Results: There is a systematic displacement of the lateral and superior aspect of the heart closer to the chest wall in the prone vs. supine position (mean displacement 19 mm (95% confidence interval 13.7-25.1 mm, p < 0.001); the medial and inferior aspects remain fixed. There was also a reduction in volume of lung interposed between the heart and chest wall when prone (mean decrease of 22 mL, p < 0.001 for difference). Conclusions: The superior and lateral aspects of the heart typically move anteriorly during prone positioning compared with the supine position. This may have negative consequences in situations in which the high-risk target tissues include the chest wall or deep breast.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A practical globalization of one-shot optimization for optimal design of tokamak divertors

In past studies, nested optimization methods were successfully applied to design of the magnetic divertor configuration in nuclear fusion reactors. In this paper, so-called one-shot optimization methods are pursued. Due to convergence issues, a globalization strategy for the one-shot solver is sought. Whereas Griewank introduced a globalization strategy using a doubly augmented Lagrangian function that includes primal and adjoint residuals, its practical usability is limited by the necessity of second order derivatives and expensive line search iterations. In this paper, a practical alternative is offered that avoids these drawbacks by using a regular augmented Lagrangian merit function that penalizes only state residuals. Additionally, robust rank-two Hessian estimation is achieved by adaptation of Powell's damped BFGS update rule. The application of the novel one-shot approach to magnetic divertor design is considered in detail. For this purpose, the approach is adapted to be complementary with practical in parts adjoint sensitivities. Using the globalization strategy, stable convergence of the one-shot approach is achieved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-126: Dosimetric Comparisons of VMAT, IMRT and 3DCRT for Locally Advanced Rectal Cancer with Simultaneous Integrated Boost

Purpose: The purpose of this study is to compare the dosimetric differences among volumetric modulated arc therapy (VMAT), fixed-field intensity modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) for the preoperative locally advanced rectal cancer (LARC). Methods: Ten LARC patients treated in our department using the simultaneous escalate strategy were retrospectively analyzed in this study. All patients had T3 with N+/− and were treated with IMRT. Two additional VMAT and 3DCRT plans were created for each patient. Both IMRT and VMAT had similar optimization objectives. The prescription was 50Gy to the PTV and 55Gy to the GTV. The target coverage and organs at risk were compared for all the techniques.The paired, two-tailed Wilcoxcon signed-rank test was applied for statistical analysis. Results: IMRT and VMAT plans achieved comparable tumor response except for the conformality index (1.07 vs 1.19 and 1.08 vs 1.03 of IMRT vs VMAT for PTV-G and PTV-C respectively). Compared to VMAT, IMRT showed superior or similar dose sparing in the small bowel, bladder, femoral head. Both IMRT and VMAT had better organs at risk sparing and homogeneity index of PTV-G. Conclusion: All 3DCRT, IMRT and VMAT meet the prescript. The IMRT and VMAT provided comparable dosemitric parameters for target volume. IMRT shows better sparing for small bowel, bladder, femoral heads and normal tissue to 3DCRT and VMAT.

60 APPLIED LIFE SCIENCES↗

DCYTB is a predictor of outcome in breast cancer that functions via iron-independent mechanisms

Background: Duodenal cytochrome b (DCYTB) is a ferrireductase that functions together with divalent metal transporter 1 (DMT1) to mediate dietary iron reduction and uptake in the duodenum. DCYTB is also a member of a 16-gene iron regulatory gene signature (IRGS) that predicts metastasis-free survival in breast cancer patients. To better understand the relationship between DCYTB and breast cancer, we explored in detail the prognostic significance and molecular function of DCYTB in breast cancer. Methods: The prognostic significance of DCYTB expression was evaluated using publicly available microarray data. Signaling Pathway Impact Analysis (SPIA) of microarray data was used to identify potential novel functions of DCYTB. The role of DCYTB was assessed using immunohistochemistry and measurements of iron uptake, iron metabolism, and FAK signaling. Results: High DCYTB expression was associated with prolonged survival in two large independent cohorts, together totaling 1610 patients (cohort #1, p = 1.6e-11, n = 741; cohort #2, p = 1.2e-05, n = 869; log-rank test) as well as in the Gene expression-based Outcome for Breast cancer Online (GOBO) cohort (p < 1.0e-05, n = 1379). High DCYTB expression was also associated with increased survival in homogeneously treated groups of patients who received either tamoxifen or chemotherapy. Immunohistochemistry revealed that DCYTB is localized on the plasma membrane of breast epithelial cells, and that expression is dramatically reduced in high-grade tumors. Surprisingly, neither overexpression nor knockdown of DCYTB affected levels of ferritin H, transferrin receptor, labile iron or total cellular iron in breast cancer cells. Because SPIA pathway analysis of patient microarray data revealed an association between DCYTB and the focal adhesion pathway, we examined the influence of DCYTB on FAK activation in breast cancer cells. These experiments reveal that DCYTB reduces adhesion and activation of focal adhesion kinase (FAK) and its adapter protein paxillin. Conclusions: DCYTB is an important predictor of outcome and is associated with response to therapy in breast cancer patients. DCYTB does not affect intracellular iron in breast cancer cells. Instead, DCYTB may retard cancer progression by reducing activation of FAK, a kinase that plays a central role in tumor cell adhesion and metastasis.

60 APPLIED LIFE SCIENCES↗

Two-Year Mortality After Angioplasty of the Femoro-Popliteal Artery with Uncoated Balloons and Paclitaxel-Coated Balloons—A Pooled Analysis of Four Randomized Controlled Multicenter Trials

Purpose: In view of a recent meta-analysis reporting increased mortality following angioplasty with paclitaxel-coated devices in peripheral arteries, we performed a patient-level 2-year mortality analysis based on pooled original data of four randomized controlled trials (THUNDER, FEMPAC, PACIFIER and CONSEQUENT). Methods and Results: Clinical data of four randomized controlled trial were pooled to assess 2-year mortality following paclitaxel-coated balloon (PCB) angioplasty compared to angioplasty without paclitaxel (control group). A logistic regression model was applied to identify potential predictors of mortality. At two years, 13 of 185 (7.0%) patients had died in the control group and 16/184 (8.7%) in the PBC group, p = 0.55. Kaplan–Meier analysis revealed no significant difference from all-cause death at 2 years (log rank p = 0.54). Causes of death were well balanced between the groups with no pattern or trend in favour of any specific causes in the PBC group. Logistic regression revealed that treatment groups (controls or PBC) were not a predictor of 2-year mortality. The only predictor for mortality was patient age ≥ 75 years. The delivered paclitaxel doses per patient were not significantly different in patients that died and those who did not die during the 24-month follow-up (5.300 ± 4.224 μg vs. 6.248 ± 4.629 μg, p = 0.433). Conclusions: Based on original patient-level data of four pooled randomized controlled trials, we found no increase in 2-year mortality in patients treated with PCB compared to control patients treated with uncoated balloons. Causes of death were well balanced between PCB and control patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a Quality and Safety Competency Curriculum for Radiation Oncology Residency: An International Delphi Study

Purpose: To develop an entry-to-practice quality and safety competency profile for radiation oncology residency. Methods and Materials: A comprehensive list of potential quality and safety competency items was generated from public and professional resources and interprofessional focus groups. Redundant or out-of-scope items were eliminated through investigator consensus. Remaining items were subjected to an international 2-round modified Delphi process involving experts in radiation oncology, radiation therapy, and medical physics. During Round 1, each item was scored independently on a 9-point Likert scale indicating appropriateness for inclusion in the competency profile. Items indistinctly ranked for inclusion or exclusion were re-evaluated through web conference discussion and reranked in Round 2. Results: An initial 1211 items were compiled from 32 international sources and distilled to 105 unique potential quality and safety competency items. Fifteen of the 50 invited experts participated in round 1: 10 radiation oncologists, 4 radiation therapists, and 1 medical physicist from 13 centers in 5 countries. Round 1 rankings resulted in 80 items included, 1 item excluded, and 24 items indeterminate. Two areas emerged more prominently within the latter group: change management and human factors. Web conference with 5 participants resulted in 9 of these 24 items edited for content or clarity. In Round 2, 12 participants rescored all indeterminate items resulting in 10 items ranked for inclusion. The final 90 enabling competency items were organized into thematic groups consisting of 18 key competencies under headings adapted from Deming's System of Profound Knowledge. Conclusions: This quality and safety competency profile may inform minimum training standards for radiation oncology residency programs.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-BRA-13: Knowledge-Based Treatment Planning for Prostate LDR Brachytherapy Based On Principle Component Analysis

Purpose: To create a knowledge-based algorithm for prostate LDR brachytherapy treatment planning that standardizes plan quality using seed arrangements tailored to individual physician preferences while being fast enough for real-time planning. Methods: A dataset of 130 prior cases was compiled for a physician with an active prostate seed implant practice. Ten cases were randomly selected to test the algorithm. Contours from the 120 library cases were registered to a common reference frame. Contour variations were characterized on a point by point basis using principle component analysis (PCA). A test case was converted to PCA vectors using the same process and then compared with each library case using a Mahalanobis distance to evaluate similarity. Rank order PCA scores were used to select the best-matched library case. The seed arrangement was extracted from the best-matched case and used as a starting point for planning the test case. Computational time was recorded. Any subsequent modifications were recorded that required input from a treatment planner to achieve an acceptable plan. Results: The computational time required to register contours from a test case and evaluate PCA similarity across the library was approximately 10s. Five of the ten test cases did not require any seed additions, deletions, or moves to obtain an acceptable plan. The remaining five test cases required on average 4.2 seed modifications. The time to complete manual plan modifications was less than 30s in all cases. Conclusion: A knowledge-based treatment planning algorithm was developed for prostate LDR brachytherapy based on principle component analysis. Initial results suggest that this approach can be used to quickly create treatment plans that require few if any modifications by the treatment planner. In general, test case plans have seed arrangements which are very similar to prior cases, and thus are inherently tailored to physician preferences.

60 APPLIED LIFE SCIENCES↗