Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Downscaling-Based Segmentation for Unresolved Images of Highly Heterogeneous Granular Porous Samples

Numerical simulations of pore-scale flow and transport in natural sediments require the knowledge of pore-space topology. Limited resolution of X-ray tomography is often insufficient to fully characterize pore-space structure within fine-grained regions. Single and multilevel threshold-based segmentation approaches are customarily employed to identify solid, pore and porous-solid regions by means of grey intensity thresholds. While the choice of cutoff thresholds is often arbitrary, it dramatically affects the effective properties and the dynamical response of the reconstructed porous structure. As such, we propose an algorithm of downscaling, i.e., the process of increasing image resolution, followed by segmentation, i.e., the identification of different phases, to reconstruct the unresolved pore-space from XCT images of natural geological porous media. The method, applicable to moderately unresolved, chemically homogeneous granular media, is based on a map between local pixel porosity and pore size that does not rely on the definition of arbitrary thresholds and it allows to generate a high-resolution binary image of the porous medium from poorly resolved grey-scale images. First, we validate the method on synthetic unresolved images and compare their known pore-space distribution with the extracted one. Then, we consider a synthetic porous medium and compare the pore size distribution, conductivity, and tortuosity between the original and the reconstructed structures. Finally, we apply the method to extract the pore-space distribution from unresolved XCT images of two natural sediment columns and use it (i) to parametrize a capillary-bundle model and (ii) to estimate the hydraulic conductivity by matching breakthrough behavior of passive solute transport.

58 GEOSCIENCES↗

Sci—Thur PM: Imaging — 05: Calibration of a SPECT/CT camera for quantitative SPECT with {sup 99m}Tc

While quantitation is the norm in PET, it is not widely available yet in SPECT. This work's aim was to calibrate a commercially available SPECT/CT system to perform quantitative SPECT. Counting sensitivity, dead-time (DT) constant and partial volume effect (PVE) of the system were assessed. A dual-head Siemens SymbiaT6 SPECT/CT camera equipped with low energy high-resolution collimators was studied. {sup 99m}Tc was the radioisotope of interest because of its wide usage in nuclear medicine. First, point source acquisitions were performed (activity: 30–990MBq). Further acquisitions were then performed with a uniform Jaszczak phantom filled with water at high activity (25–5000MBq). PVE was studied using 6 hot spheres (diameters: 9.9–31.2 mm) filled with {sup 99m}Tc (2.8MBq/cc) in the Jaszczak phantom, which was: (1) empty, (2) water-filled and (3) water-filled with low activity (0.1MBq/cc). The data was reconstructed with the Siemens's Flash3D iterative algorithm with 4 subsets and 8 iterations, attenuation-correction (AC) and scatter-correction (SC). DT modelling was based on the total spectrum counting rate. Sensitivity was assessed using AC-SC reconstructed SPECT data. Sensitivity and DT for the sources were 99.51±1.46cps/MBq and 0.60±0.04µs. For the phantom, sensitivity and DT were 109.9±2.3cps/MBq and 0.62±0.13µs. The recovery-coefficient varied from 5% for the 9.9mm, to 80% for the 31.2mm spheres. With our calibration methods, both sensitivity and DT constant of the SPECT camera had little dependence on the object geometry and attenuation. For small objects of known size, recovery-coefficient can be applied to correct PVE. Clinical quantitative SPECT appears to be possible and has many potential applications.

07 ISOTOPE AND RADIATION SOURCES↗

Water Management In PEM Fuel Cell -“ A Lattice-Boltzmann Modeling Approach

In Proton Exchange Membrane Fuel Cells (PEMFCs), water management and the effective transport of water through the gas-diffusion-layer (GDL) are key issues for improved performance at high power density and for durability during freeze-thaw cycles. The diffusion layer is a thin (~150-350{micro}m), porous material typically composed of a web of carbon fibers and particles, and is usually coated with hydrophobic Teflon to remove the excess water through capillary action. In-situ diagnostics of water movement and gas-reactant transport through this thin opaque substrate is challenging. Numerical analyses are typically based on simplified assumptions, such as Darcy's Law and Leverett functions for the capillary pressure. The objective of this work is to develop a high fidelity CFD modeling and analysis tool to capture the details of multiphase transport through the porous GDL. The tool can be utilized to evaluate GDL material design concepts and optimize systems based on the interactions between cell design, materials, and operating conditions. The flow modeling is based on the Lattice Boltzmann Method (LBM). LBM is a powerful modeling tool to simulate multiphase flows. Its strength is in its kinetic theory based foundation, which provides a fundamental basis for incorporating intermolecular forces that lead to liquid-gas phase separation and capillary effects without resorting to expensive or ad-hoc interface reconstruction schemes. At the heart of the solution algorithm is a discrete form of the well-known Boltzmann Transport Equation (BTE) for molecular distribution, tailored to recover the continuum Navier-Stokes flow. The solution advances by a streaming and collision type algorithm, mimicking actual molecular physics, which makes it suitable for porous media involving complex boundaries. We developed a numerical scheme to reconstruct various porous GDL microstructures including Teflon loading. Single and multiphase LBM models are implemented to compute permeability. Predicted values are in good agreement with measured data. The present modeling approach resolves the GDL microstructures and captures the influence of fiber orientation on permeability and the influence of Teflon loading on the development of preferential flow paths through the GDL. These observations can potentially guide the development of novel GDL materials designed for efficient removal of water.

30 DIRECT ENERGY CONVERSION↗

Performance of the Moving Voxel Image Reconstruction (MVIR) Method in the Fixed Site Detection System (FSDS) Prototype

We have developed a dynamic image reconstruction method called MVIR (Moving Voxel Image Reconstruction) for lane detection in multilane portal monitor systems. MVIR was evaluated for use in the Fixed Site Detection System, a prototype three-lane portal monitor system for EZ-pass toll plazas. As a baseline, we compared MVIR with a static image reconstruction method in analyzing the same real and simulated data sets. Performance was judged by the distributions of image intensities for source and no-source vehicles over many trials as a function of source strength. We found that MVIR produced significantly better results in all cases. The performance difference was greatest at low count rates, where source/no-source distributions were well separated with the MVIR method, allowing reliable source vehicle identification with a low probability of false positive identifications. Static reconstruction of the same data produced overlapping distributions that made source vehicle identification unreliable. The performance of the static method was acceptable at high count rates. Both algorithms reliably identified two strong sources passing through at nearly the same time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of Shielding Material Configurations Using NMIS Imaging

The Nuclear Materials Identification System (NMIS) uses fast neutron tomographic imaging to nonintrusively examine the interior structure of shielded objects. The pixel values in such images represent the attenuation coefficients of the time and directionally tagged fast neutrons from a deuterium-tritium (DT) neutron generator. The reconstruction techniques use either a filtered back projection or a maximum likelihood expectation maximization algorithm. As a first test of the capabilities of these reconstruction techniques to correctly identify individual parts inside of an object, fast neutron imaging was used to identify the regions of shielding surrounding a depleted uranium casting from a library of possible parts. The shielding consisted of multiple regions of common materials such as steel, lead, aluminum, and polyethylene. First, the full object was imaged, and then each of the individual parts was imaged. Several additional parts that were not present in the original object were also imaged to form a library. The individual parts were compared to the full object, and the correct ones were identified using three different methods. These methods included a visual match, an iterative fit of each part, and a mathematical test comparing the sum of squared errors. The successful results demonstrate an initial application of matching. This suggests that it should be possible to implement more sophisticated matching techniques using automated pixel-by-pixel comparison methods in the future.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reconstructing magnetic deflections from sets of proton images using differential evolution

Proton imaging is a powerful technique for imaging electromagnetic fields within an experimental volume, in which spatial variations in proton fluence are a result of deflections to proton trajectories due to interaction with the fields. When deflections are large, proton trajectories can overlap, and this nonlinearity creates regions of greatly increased proton fluence on the image, known as caustics. The formation of caustics has been a persistent barrier to reconstructing the underlying fields from proton images. We have developed a new method for reconstructing the path-integrated magnetic fields, which begins to address the problem posed by caustics. Our method uses multiple proton images of the same object, each image at a different energy, to fill in the information gaps and provide some uniqueness when reconstructing caustic features. We use a differential evolution algorithm to iteratively estimate the underlying deflection function, which accurately reproduces the observed proton fluence at multiple proton energies simultaneously. We test this reconstruction method using synthetic proton images generated for three different, cylindrically symmetric field geometries at various field amplitudes and levels of proton statistics and present reconstruction results from a set of experimental images. Here, the method we propose requires no assumption of deflection linearity and can reliably solve for fields underlying linear, nonlinear, and caustic proton image features for the selected geometries and is shown to be fairly robust to noise in the input proton intensity.

47 OTHER INSTRUMENTATION↗

An experimental comparison of various methods of nearfield acoustic holography

An experimental comparison of four different methods of nearfield acoustic holography (NAH) is presented in this study for planar acoustic sources. The four NAH methods considered in this study are based on: (1) spatial Fourier transform, (2) equivalent sources model, (3) boundary element methods and (4) statistically optimized NAH. Two dimensional measurements were obtained at different distances in front of a tonal sound source and the NAH methods were used to reconstruct the sound field at the source surface. Reconstructed particle velocity and acoustic pressure fields presented in this study showed that the equivalent sources model based algorithm along with Tikhonov regularization provided the best localization of the sources. Reconstruction errors were found to be smaller for the equivalent sources model based algorithm and the statistically optimized NAH algorithm. Effect of hologram distance on the performance of various algorithms is discussed in detail. The study also compares the computational time required by each algorithm to complete the comparison. Four different regularization parameter choice methods were compared. The L-curve method provided more accurate reconstructions than the generalized cross validation and the Morozov discrepancy principle. Finally, the performance of fixed parameter regularization was comparable to that of the L-curve method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of a multi-detector, single line-of-sight, time-of-flight system to measure time-resolved neutron energy spectra

In the dynamic environment of burning, thermonuclear deuterium–tritium plasmas, diagnosing the time-resolved neutron energy spectrum is of critical importance. Strategies exist for this diagnosis in magnetic confinement fusion plasmas, which presently have a lifetime of ~10 12 longer than inertial confinement fusion (ICF) plasmas. In this work, we present a novel concept for a simple, precise, and scale-able diagnostic to measure time-resolved neutron spectra in ICF plasmas. The concept leverages general tomographic reconstruction techniques adapted to time-of-flight parameter space, and then employs an updated Monte Carlo algorithm and National Ignition Facility-relevant constraints to reconstruct the time-evolving neutron energy spectrum. Reconstructed spectra of the primary 14.028 MeV n DT peak are in good agreement with the exact synthetic spectra. The technique is also used to reconstruct the time-evolving downscattered spectrum, although the present implementation shows significantly more error.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing light-traces-mass in Hubble Frontier Fields Cluster MACS-J0416.1-2403

Here, we reconstruct the projected mass distribution of a massive merging Hubble Frontier Fields cluster MACSJ0416 using the genetic algorithm based free-form technique called Grale. The reconstructions are constrained by 149 lensed images identified by Jauzac et al. using HFF data. No information about cluster galaxies or light is used, which makes our reconstruction unique in this regard. Using visual inspection of the maps, as well as galaxy-mass correlation functions we conclude that overall light does follow mass. Furthermore, the fact that brighter galaxies are more strongly clustered with mass is an important confirmation of the standard biasing scenario in galaxy clusters. On the smallest scales, approximately less than a few arcseconds, the resolution afforded by 149 images is still not sufficient to confirm or rule out galaxy-mass offsets of the kind observed in ACO 3827. We also compare the mass maps of MACSJ0416 obtained by three different groups: Grale, and two parametric Lenstool reconstructions from the CATS and Sharon/Johnson teams. Overall, the three agree well; one interesting discrepancy between Grale and Lenstool galaxy-mass correlation functions occurs on scales of tens of kpc and may suggest that cluster galaxies are more biased tracers of mass than parametric methods generally assume.

79 ASTRONOMY AND ASTROPHYSICS↗

Dual X-ray computed tomography-aided classification of melt pool boundaries and flaws in crept additively manufactured parts

In metal additive manufacturing (AM), understanding the process-structure-performance relationships requires a combination of multi-scale characterization techniques that allows for the measurement of the melt pool shape and boundary and classifying various defects and flaws in the AM parts. Such approaches can be destructive, only 2D in nature, or have a small field of view and can be complex to co-register and analyze. Here, in this work, we present a non-destructive 3D inspection technique that employs dual-energy X-ray computed tomography (XCT) along with a model-based iterative reconstruction (MBIR) and a new segmentation algorithm. The proposed approach and algorithm are not only capable of classifying and quantifying flaws such as pores, cracks, and inclusions, but they also allow for the extraction of microstructural features such as melt pool boundaries (MPB) and melt pool regions (MPR), that can help understand process-structure-performance relationships for alloys under study. As an exemplar application, we employed the method for characterization of an additively manufactured aluminum alloy crept under tensile stress at 300 °C for 1064 h. Our results demonstrate high quality segmentation and classification of various flaws and MPB and MPR, for the first time, using 3D X-ray CT inspection. The delineated MPB and MPR in the crept samples reveal the preferential growth paths of cracks that formed during creep deformation. The technique was used for successfully quantifying the characteristics (number of defects, their density, volume fraction, etc.) of the manufacturing-induced pores and creep-induced cracks, which is necessary to better understand the creep failure mechanisms of the material.

36 MATERIALS SCIENCE↗

Dynamic X-ray diffraction sampling for protein crystal positioning

A sparse supervised learning approach for dynamic sampling (SLADS) is described for dose reduction in diffraction-based protein crystal positioning. Crystal centering is typically a prerequisite for macromolecular diffraction at synchrotron facilities, with X-ray diffraction mapping growing in popularity as a mechanism for localization. In X-ray raster scanning, diffraction is used to identify the crystal positions based on the detection of Bragg-like peaks in the scattering patterns; however, this additional X-ray exposure may result in detectable damage to the crystal prior to data collection. Dynamic sampling, in which preceding measurements inform the next most information-rich location to probe for image reconstruction, significantly reduced the X-ray dose experienced by protein crystals during positioning by diffraction raster scanning. The SLADS algorithm implemented herein is designed for single-pixel measurements and can select a new location to measure. In each step of SLADS, the algorithm selects the pixel, which, when measured, maximizes the expected reduction in distortion given previous measurements. Ground-truth diffraction data were obtained for a 5 µm-diameter beam and SLADS reconstructed the image sampling 31% of the total volume and only 9% of the interior of the crystal greatly reducing the X-ray dosage on the crystal. Furthermore, by using in situ two-photon-excited fluorescence microscopy measurements as a surrogate for diffraction imaging with a 1 µm-diameter beam, the SLADS algorithm enabled image reconstruction from a 7% sampling of the total volume and 12% sampling of the interior of the crystal. When implemented into the beamline at Argonne National Laboratory, without ground-truth images, an acceptable reconstruction was obtained with 3% of the image sampled and approximately 5% of the crystal. The incorporation of SLADS into X-ray diffraction acquisitions has the potential to significantly minimize the impact of X-ray exposure on the crystal by limiting the dose and area exposed for image reconstruction and crystal positioning using data collection hardware present in most macromolecular crystallography end-stations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lossy compression of statistical data using quantum annealer

Abstract We present a new lossy compression algorithm for statistical floating-point data through a representation learning with binary variables. The algorithm finds a set of basis vectors and their binary coefficients that precisely reconstruct the original data. The optimization for the basis vectors is performed classically, while binary coefficients are retrieved through both simulated and quantum annealing for comparison. A bias correction procedure is also presented to estimate and eliminate the error and bias introduced from the inexact reconstruction of the lossy compression for statistical data analyses. The compression algorithm is demonstrated on two different datasets of lattice quantum chromodynamics simulations. The results obtained using simulated annealing show 3–3.5 times better compression performance than the algorithm based on neural-network autoencoder. Calculations using quantum annealing also show promising results, but performance is limited by the integrated control error of the quantum processing unit, which yields large uncertainties in the biases and coupling parameters. Hardware comparison is further studied between the previous generation D-Wave 2000Q and the current D-Wave Advantage system. Our study shows that the Advantage system is more likely to obtain low-energy solutions for the problems than the 2000Q.

97 MATHEMATICS AND COMPUTING↗

Technology Review of Nondestructive Methods for Examination of Water Intrusion Areas on Hanford’s Double-Shell Waste Tanks

Under a contract with CH2M Hill Hanford Group, Inc., PNNL has performed a review of the NDE technology and methods for examination of the concrete dome structure of Hanford’s double-shell tanks. The objective was to provide a matrix of methodologies that could be evaluated based on applicability, ease of deployment, and results that could provide information that could be used in the ongoing structural analysis of the tank dome. PNNL performed a technology evaluation with the objective of providing a critical literature review for all applicable technologies based on constraints provided by CH2M HILL. These constraints were not mandatory, but were desired. These constraints included performing the evaluation without removing any soil from the top of the tank, or if necessary, requesting that the hole diameter needed to gain access to evaluate the top of the tank structure to be no greater than approximately 12-in. in diameter. PNNL did not address the details of statistical sampling requirements as they depend on an unspecified risk tolerance. PNNL considered these during the technology evaluation and have reported the results in the remainder of this document. Many of the basic approaches to concrete inspection that were reviewed in previous efforts are still in use. These include electromagnetic, acoustic, radiographic, etc. The primary improvements in these tools have focused on providing quantitative image reconstruction, thus providing inspectors and analysts with three-dimensional data sets that allow for operator visualization of relevant abnormalities and analytical integration into structural performance models. Available instruments, such as radar used for bridge deck inspections, rely on post-processing algorithms and do not provide real-time visualization. Commercially available equipment only provides qualitative indications of relative concrete damage. It cannot be used as direct input for structural analysis to assess fitness for use and if necessary to de-rate critical components. There are currently no tools that automatically convert the NDE data to formats compatible with structural analysis programs. While radiographic techniques still provide significant advantages in spatial resolution, non-ionizing techniques are still preferred. Radar imagining in the 1–5 GHz has become the most useful. Unfortunately the algorithms and underlying assumptions used in these reconstructions are proprietary, and it is not possible to assess the quality and limitations of the analytical methods used to generate the derived structural data. The hypothesis that water intrusion may contribute to potential rebar corrosion of the tank domes provided the primary guidance in reviewing and evaluating available NDE technologies. Of primary concern is the need to employ technologies that provide the best opportunity for visualizing the rebar and providing quantitative data that can be integrated into structural analysis efforts to better understand and quantify the structural capacity of the domes. The conclusion is that an imaging system capable of locating and quantifying the distribution and conditions of the cement, aggregate, and rebar will provide the most valuable baseline upon which to build a case for the integrity of the structure. If successful, such a system would fulfill the need to incorporate valuable data into current structural load capacity analysis.

54 ENVIRONMENTAL SCIENCES↗

Efficient reconstruction and validation of heterogeneous microstructures for energy applications

The digital reconstruction of microstructures is necessary for simulations in fields ranging from geology to electrochemistry, but the state-of-the-art digital reconstruction techniques often compromise between resolution and field of view. It is challenging to retain detailed microstructure information in large-scale reconstructions. Here, this study investigates different aspects of the Yeong-Torquato algorithm based on correlation functions to make it more efficient. We achieve this goal by reducing the computational complexity of the chord-length distribution function and the two-point correlation function, applying the random sphere-packing method as the initial condition, and restricting potential voxel swaps to interfaces. In addition, a novel superposition parallel scheme is introduced to aid in searching for potential voxel swaps. The algorithm proposed is validated by comparing the pore-size distributions of reconstructed 3D custom battery electrodes from a sample dataset obtained from transmission X-ray microscopy. From a sample image with 200 x 200 pixels, the code can reconstruct a 300 x 300 x 300 structure in under 22 h and reconstruct a 400 x 400 x 400 structure in 43 h with eight cores.

42 ENGINEERING↗

Measurement of dijet cross-sections in pp collisions at 7 TeV centre-of-mass energy using the ATLAS detector

Double-differential dijet cross-sections measured in pp collisions at the LHC with a 7 TeV centre-of-mass energy are presented as functions of dijet mass and half the rapidity separation of the two highest-p T jets. These measurements are obtained using data corresponding to an integrated luminosity of 4.5 fb -1 , recorded by the ATLAS detector in 2011. The data are corrected for detector effects so that cross-sections are presented at the particle level. Cross-sections are measured up to 5TeV dijet mass using jets reconstructed with the anti- k t algorithm for values of the jet radius parameter of 0.4 and 0.6. The cross-sections are compared with next-to-leading-order perturbative QCD calculations by NLOJet++ corrected to account for non-perturbative effects. Comparisons with POWHEG predictions, using a next-to-leading-order matrix element calculation interfaced to a partonshower Monte Carlo simulation, are also shown. Electroweak effects are accounted for in both cases. The quantitative comparison of data and theoretical predictions obtained using various parameterizations of the parton distribution functions is performed using a frequentist method. In general, good agreement with data is observed for the NLOJet++ theoretical predictions when using the CT10, NNPDF2.1 and MSTW 2008 PDF sets. Disagreement is observed when using the ABM11 and HERAPDF1.5 PDF sets for some ranges of dijet mass and half the rapidity separation. An example setting a lower limit on the compositeness scale for a model of contact interactions is presented, showing that the unfolded results can be used to constrain contributions to dijet production beyond that predicted by the Standard Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Shape, Transverse Size, and Charged Hadron Multiplicity of Jets in pp Collisions at 7 TeV

Measurements of jet characteristics from inclusive jet production in proton-proton collisions at a centre-of-mass energy of 7 TeV are presented. The data sample was collected with the CMS detector at the LHC during 2010 and corresponds to an integrated luminosity of 36 inverse picobarns. The mean charged hadron multiplicity, the differential and integral jet shape distributions, and two independent moments of the shape distributions are measured as functions of the jet transverse momentum for jets reconstructed with the anti-kT algorithm. The measured observables are corrected to the particle level and compared with predictions from various QCD Monte Carlo generators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diffusion tensor imaging of the kidney in healthy controls and in children and young adults with autosomal recessive polycystic kidney disease

Objective: To compare diffusion tensor imaging (DTI) of the kidneys and its derived parameters in children with autosomal recessive polycystic kidney disease (ARPKD) versus healthy controls. Methods: In a prospective IRB-approved study, we evaluated the use of DTI to compare kidney parenchyma FA values in healthy controls (age-matched children with no history of renal disease) versus patients with ARPKD. A 20-direction DTI with b-values of b = 0 s/mm{sup 2} and b = 400 s/mm{sup 2} was used to acquire data in coronal direction using a fat-suppressed spin-echo echo-planar sequence. Diffusion Toolkit and TrackVis were used for analysis and segmentation. TrackVis was used to draw regions of interest (ROIs) covering the entire volume of the renal parenchyma, excluding the collecting system. Fibers were reconstructed using a deterministic fiber tracking algorithm. The FA values based on the ROI data, mean length, and volume of the tracks based on the fiber tracking data were recorded. Results: Eight healthy controls (mean age = 12.9 years ± 4.0; 1/8 males) and six ARPKD participants (mean age = 13.8 years ± 8.5; 5/6 males) were included in the study. Compared to healthy controls, patients with ARPKD had significantly lower FA values (0.33 ± 0.03 vs. 0.25 ± 0.02, p = 0.002) and mean track length (16.73 ± 3.43 vs. 11.61 ± 1.29 mm, p = 0.005). Conclusion: DTI of the kidneys shows significantly lower FA values and mean track length in children and young adults with ARPKD compared to normal subjects. DTI of the kidney offers a novel approach for characterizing renal disease based on changes in diffusion anisotropy and kidney structure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗