Simulating Scintillator Light Collection Using Measured Optical Reflectance

To accurately predict the light collection from a scintillating crystal through Monte Carlo simulations, it is crucial to know the angular distribution from the surface reflectance. Current Monte Carlo codes allow the user to set the optical reflectance to a linear combination of backscatter spike, specular spike, specular lobe, and Lambertian reflections. However, not all light distributions can be expressed in this way. In addition, the user seldom has the detailed knowledge about the surfaces that is required for accurate modeling. We have previously measured the angular distributions within BGO crystals and now incorporate these data as look-up-tables (LUTs) into modified Geant4 and GATE Monte Carlo codes. The modified codes allow the user to specify the surface treatment (ground, etched, or polished), the attached reflector (Lumirror(R), Teflon(R), ESR film, Tyvek(R), or TiO paint), and the bonding type (air-coupled or glued). Each LUT consists of measured angular distributions with 4o by 5o resolution in theta and phi, respectively, for incidence angles from 0? to 90? degrees, in 1o-steps. We compared the new codes to the original codes by running simulations with a 3 x 10 x 30 mm3 BGO crystal coupled to a PMT. The simulations were then compared to measurements. Light output was measured by counting the photons detected by the PMT with the 3 x 10, 3 x 30, or 10 x 30 mm2 side coupled to the PMT, respectively. Our new code shows better agreement with the measured data than the current Geant4 code. The new code can also simulate reflector materials that are not pure specular or Lambertian reflectors, as was previously required. Our code is also more user friendly, as no detailed knowledge about the surfaces or light distributions is required from the user.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Onset of Fogging and Degradation in Polyvinyl Toluene-Based Scintillators

Plastic-based gamma-ray detector materials such as polyvinyl toluene (PVT) occasionally suffer from loss of optical light transmission due to internal defects or “fogging” when exposed to some environmental conditions over time. Fogging results in reduced scintillation light propagated to the photomultiplier tube for collection. Investigations of the physical cause of these defects and their associated environmental conditions are ongoing. The goal of this work was to characterize the signs and effects of fogging over a simulated 22-year lifespan of the PVT in outdoor environments. Here, two potential mitigation methods were also evaluated, and one successfully mitigated the phenomena.

36 MATERIALS SCIENCE↗

Processing of transparent polycrystalline AlON:Ce 3+ scintillators

A new polycrystalline ceramic scintillator is reported for potential use in radiation detection and medical imaging applications. The goal was to develop cerium-activated aluminum oxynitride (AlON:Ce 3+ ) ceramics, which can be produced using ceramic processes in comparison to the high-cost, low-yield single-crystal growth technique. A phase pure AlON:Ce 3+ powder with cubic symmetry was successfully synthesized at high temperature under a reducing atmosphere to convert Ce 4+ to Ce 3+ in the solid solution. We explored two different activator concentrations (0.5 and 1.0 mol%). Fully dense and transparent AlON:Ce 3+ ceramics were produced by a liquid-phase-assisted pressureless sintering. The crystal field splitting around the Ce 3+ activator in the AlON was comparable to the splitting induced by Br₋ and the Cl₋ ligands, which produced an emission spectrum perfectly matching the maximum quantum efficiency range of the photomultiplier tube for radiation detection. Both optical excitation and radiation ionizations in AlON:Ce 3+ were demonstrated. Lastly, challenges and mechanisms related to the radioluminescence efficiency are discussed.

36 MATERIALS SCIENCE↗

Light emission efficiency and imaging performance of Gd{sub 2}O{sub 2}S:Eu powder scintillator under x-ray radiography conditions

Purpose: To evaluate Gd{sub 2}O{sub 2}S:Eu powder phosphor as a radiographic image receptor and to compare it to phosphors often used in radiography. Gd{sub 2}O{sub 2}S:Eu is nonhygroscopic, emitting red light with decay time close to that of Gd{sub 2}O{sub 2}S:Tb. Methods: The light intensity emitted per unit of x-ray exposure rate (absolute luminescence efficiency) was measured for laboratory prepared screens with coating thicknesses of 33.1, 46.4, 63.1, 78.3, and 139.8 mg/cm{sup 2} and tube voltages ranging from 50 to 140 kVp. Parameters related to image quality such as the modulation transfer function (MTF) and the detective quantum efficiency (DQE) were also experimentally examined. In addition, a previously validated Monte Carlo code was used to estimate intrinsic x-ray absorption and optical properties, as well as the MTF and the Swank factor (I) of the Gd{sub 2}O{sub 2}S:Eu scintillators. Results: Gd{sub 2}O{sub 2}S:Eu light intensity was found higher than that of single CsI:Tl crystal for tube voltages up to 100 kVp. The MTF and the DQE were found to be comparable with those of Gd{sub 2}O{sub 2}S:Tb and CsI:Tl screens. MTF estimated by the Monte Carlo code was found very close to the experimental MTF values. Gd{sub 2}O{sub 2}S:Eu showed peak emission in the wavelength range 620-630 nm. Its emission spectrum was excellently matched to various optical detectors (photodiodes, photocathodes, CCDs, and CMOS) employed in flat panel detectors. Conclusions: Gd{sub 2}O{sub 2}S:Eu is an efficient phosphor potentially well suited to radiography and especially to some digital detectors sensitive to red light.

36 MATERIALS SCIENCE↗

Sci—Sat AM: Stereo — 07: Suitability of a plastic scintillator dosimeter for composite clinical fields delivered using the Cyberknife robotic radiosurgery system

Plastic scintillation dosimeters (PSDs) have favourable characteristics for small and composite field dosimetry in radiosurgery, however, imperfect corrections for the Cerenkov radiation contamination could limit their accuracy for complex deliveries. In this work, we characterize the dose and dose-rate linearity, directional dependence, and compare output factors with other stereotactic detectors for a new commercially available PSD (Exradin W1). We provide some preliminary comparisons of planned and measured dose for composite fields delivered clinically by a Cyberknife radiosurgery system. The W1 detector shows good linearity with dose (<0.5%) and dose rate (<0.8%) relative to the signal obtained using an ion chamber under the same conditions. A maximum difference of 2% was observed depending on the detector's angular orientation. Output factors for all detectors agree within a range of ±3.2% and ±1.5% for the 5 and 7.5 mm collimators, respectively, provided Monte-Carlo corrections for detector effects are applied to diode and ion chambers (without corrections the range is ±5.5% and ±3.1% for these two collimators). For clinical beam deliveries using 5 and 7.5 mm collimators, four of the six patients showed better agreement with planned dose for the PSD detector compared to a micro ion chamber. Two of the six patients investigated, however, showed 5% differences between PSD and planned dose, film measurements and the ratio of PSD and micro ion chamber signal suggest that further investigation is warranted for these plans. The W1 detector is a promising tool for stereotactic plan verification under the challenging dosimetric conditions of stereotactic radiosurgery.

60 APPLIED LIFE SCIENCES↗

SU-E-T-774: Use of a Scintillator-Mirror-Camera System for the Measurement of MLC Leakage Radiation with the CyberKnife M6 System

Purpose: A technique using a scintillator-mirror-camera system to measure MLC leakage was developed to provide an efficient alternative to film dosimetry while maintaining high spatial resolution. This work describes the technique together with measurement uncertainties. Methods: Leakage measurements were made for the InCise™ MLC using the Logos XRV-2020A device. For each measurement approximately 170 leakage and background images were acquired using optimized camera settings. Average background was subtracted from each leakage frame before filtering the integrated leakage image to replace anomalous pixels. Pixel value to dose conversion was performed using a calibration image. Mean leakage was calculated within an ROI corresponding to the primary beam, and maximum leakage was determined by binning the image into overlapping 1mm x 1mm ROIs. 48 measurements were performed using 3 cameras and multiple MLC-linac combinations in varying beam orientations, with each compared to film dosimetry. Optical and environmental influences were also investigated. Results: Measurement time with the XRV-2020A was 8 minutes vs. 50 minutes using radiochromic film, and results were available immediately. Camera radiation exposure degraded measurement accuracy. With a relatively undamaged camera, mean leakage agreed with film measurement to ≤0.02% in 92% cases, ≤0.03% in 100% (for maximum leakage the values were 88% and 96%) relative to reference open field dose. The estimated camera lifetime over which this agreement is maintained is at least 150 measurements, and can be monitored using reference field exposures. A dependency on camera temperature was identified and a reduction in sensitivity with distance from image center due to optical distortion was characterized. Conclusion: With periodic monitoring of the degree of camera radiation damage, the XRV-2020A system can be used to measure MLC leakage. This represents a significant time saving when compared to the traditional film-based approach without any substantial reduction in accuracy.

60 APPLIED LIFE SCIENCES↗

Atmospheric charged $$K/\pi $$ ratio and measurement of muon annual modulation with a liquid scintillation detector at Soudan

We report a measurement of muon annual modulation in a 12-l liquid scintillation detector with a live-time of more than 4 years at the Soudan Underground Laboratory. Muon minimum ionization in the detector is identified by its observed pulse shape and large energy deposition. The measured muon rate in the detector is $$28.69\pm 2.09$$ 28.69 ± 2.09 muons per day with a modulation amplitude of ( $$2.64\pm 0.07$$ 2.64 ± 0.07 )% and a phase at Jul $$22 \pm 36.2$$ 22 ± 36.2 days. This annual modulation is correlated with the variation of the effective atmospheric temperature in the stratosphere. The correlation coefficient, $$\alpha _{T}$$ α T , is determined to be $$0.898 \pm 0.025$$ 0.898 ± 0.025 . This can be interpreted as a measurement of the atmospheric charged kaon to pion ( $$K/\pi $$ K / π ) ratio of $$0.094^{+0.044}_{-0.061}$$ 0 . 094 - 0.061 + 0.044 for $$E_{p} > 7$$ E p > 7 TeV, consistent with the measurement from the MINOS far detector. To further constrain the value of $$K/\pi $$ K / π ratio, a Geant4 simulation of the primary cosmic-ray protons with energy up to 100 TeV is implemented to study the correlation of $$K/\pi $$ K / π ratio and the muon annual modulation for muon energy greater than 0.5 TeV. We find out that a charged $$K/\pi $$ K / π ratio of 0.1598, greater than the upper bound (0.138) from this work at the production point 30 km above the Earth surface in the stratosphere cannot induce muon annual modulation at the depth of Soudan.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scintillation light in SBND: simulation, reconstruction, and expected performance of the photon detection system

SBND is the near detector of the Short-Baseline Neutrino program at Fermilab. Its location near to the Booster Neutrino Beam source and relatively large mass will allow the study of neutrino interactions on argon with unprecedented statistics. This paper describes the expected performance of the SBND photon detection system, using a simulated sample of beam neutrinos and cosmogenic particles. Its design is a dual readout concept combining a system of 120 photomultiplier tubes, used for triggering, with a system of 192 X-ARAPUCA devices, located behind the anode wire planes. Furthermore, covering the cathode plane with highly-reflective panels coated with a wavelength-shifting compound recovers part of the light emitted towards the cathode, where no optical detectors exist. We show how this new design provides a high light yield and a more uniform detection efficiency, an excellent timing resolution and an independent 3D-position reconstruction using only the scintillation light. Finally, the whole reconstruction chain is applied to recover the temporal structure of the beam spill, which is resolved with a resolution on the order of nanoseconds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-Ray Simulated Spectrum Deconvolution of a LaBr₃ 1-in. x 1-in. Scintillator for Nondestructive ATR Fuel Burnup On-Site Predictions

A deconvolution method for a LaBr₃ 1"x1" detector for nondestructive Advanced Test Reactor (ATR) fuel burnup applications was developed. The method consisted of obtaining the detector response function, applying a deconvolution algorithm to 1”x1” LaBr₃ simulated, data along with evaluating the effects that deconvolution have on nondestructively determining ATR fuel burnup. The simulated response function of the detector was obtained using MCNPX as well with experimental data. The Maximum-Likelihood Expectation Maximization (MLEM) deconvolution algorithm was selected to enhance one-isotope source-simulated and fuel- simulated spectra. The final evaluation of the study consisted of measuring the performance of the fuel burnup calibration curve for the convoluted and deconvoluted cases. The methodology was developed in order to help design a reliable, high resolution, rugged and robust detection system for the ATR fuel canal capable of collecting high performance data for model validation, along with a system that can calculate burnup and using experimental scintillator detector data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Soft x-ray free-electron laser induced damage to inorganic scintillators

An irreversible response of inorganic scintillators to intense soft x-ray laser radiation was investigated at the FLASH (Free-electron LASer in Hamburg) facility. Three ionic crystals, namely, Ce:YAG (cerium-doped yttrium aluminum garnet), PbWO4 (lead tungstate), and ZnO (zinc oxide), were exposed to single 4.6 nm ultra-short laser pulses of variable pulse energy (up to 12 μJ) under normal incidence conditions with tight focus. Damaged areas produced with various levels of pulse fluences, were analyzed on the surface of irradiated samples using differential interference contrast (DIC) and atomic force microscopy (AFM). The effective beam area of 22.2 ± 2.2 μm2 was determined by means of the ablation imprints method with the use of poly(methyl methacrylate) - PMMA. Applied to the three inorganic materials, this procedure gave almost the same values of an effective area. The single-shot damage threshold fluence was determined for each of these inorganic materials. The Ce:YAG sample seems to be the most radiation resistant under the given irradiation conditions, its damage threshold was determined to be as high as 660.8 ± 71.2 mJ/cm2. Contrary to that, the PbWO4 sample exhibited the lowest radiation resistance with a threshold fluence of 62.6 ± 11.9 mJ/cm2. The threshold for ZnO was found to be 167.8 ± 30.8 mJ/cm2. Both interaction and material characteristics responsible for the damage threshold difference are discussed in the article.

36 MATERIALS SCIENCE↗

Upgrade to Fixed and Translating Scintillation-based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and operational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating detectors collected under varying beam conditions validate the utility of the upgrade.

Chen, E. V. [Fermilab]↗

Characterization of Final State Interaction Strength in Plastic Scintillator by Muon-Neutrino Charged Current Charged Pion Production

Precise knowledge of neutrino-nucleus interactions is increasingly important as neutrino oscillation measurements transition into the systematics-limited era. In addition to modifying the initial interaction, the nuclear medium can scatter and absorb the interaction by-products through final state interactions, changing the types and kinematic distributions of particles seen by the detector. Recent neutrino pion production data from MiniBooNE is inconsistent with the final state interaction strength predicted by models and theoretical calculations, and some models fit best to the MiniBooNE data only after removing final state interactions entirely. This thesis presents a measurement of dσ/dT π and dσ/dθ π for muon-neutrino charged current charged pion production in the MINER A scintillator tracker. MINER A is a neutrino-nucleus scattering experiment installed in the few-GeV NuMI beam line at Fermilab. The analysis is limited to neutrino energies between 1.5-10 GeV. Dependence on invariant hadronic mass W is studied through two versions of the analysis that impose the limits W < 1.4 GeV and W < 1.8 GeV. The lower limit on W increases compatibility with the MiniBooNE pion data. The shapes of the differential cross sections, which depend strongly on the nature of final state interactions, are compared to Monte Carlo and theoretical predictions. It is shown that the measurements presented in this thesis favor models that contain final state interactions. Additionally, a variety of neutrino-nucleus interaction models are shown to successfully reproduce the thesis measurements, while simultaneously failing to describe the shape of the MiniBooNE data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accelerated discovery of elpasolite scintillators

Elpasolite scintillators are a large family of halides which includes compounds reported to meet the NA22 program goals of <3% energy resolution at 662 keV1. This work investigated the potential to produce quality elpasolite compounds and alloys of useful sizes at reasonable cost, through systematic experimental and computational investigation of crystal structure and properties across the composition space. Discovery was accelerated by computational methods and models developed previously to efficiently identify cubic members of the elpasolite halides, and to evaluate stability of anion and cation exchange alloys.

36 MATERIALS SCIENCE↗

Scintillator Optimization Study for Nuclear Nonproliferation, Safeguards, and Security Based Applications

The following report summarizes my overall research and experience in the Department of Homeland Security HS-STEM Summer Internship Program at the Idaho National Laboratory. First, I give an introduction to scintillators principles. This includes the basic physics and methodology for radiation detection. Secondly, an introduction to my work is presented which includes the problem and approach. Next, I summarize the skills I learned in the internship as well as interesting knowledge that I was exposed to. I finish with my future career plans as well as acknowledgements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of cross-section of charge current inclusive of antineutrino scattering off nucleons using carbon, iron, lead and scintillator at MINER$\nu$A for 2GeV $<$ E$\nu$ $<$ 20GeV

Neutrino physics is one of the most active fields in the domaine of high energy physics during the last century. The need of precise measurement of neutrino-nucleus interactions required by the neutrino oscillation experiments is a an exiting step. These measurements of cross-section are more than essential for neutrino oscillation experiment. Over the year, many measurements from varieties of experiments have been presented. MINERνA is one of the world leaders in measuring cross-section of neutrino and antineutrino -nucleus interactions. MINERνA is a neutrino-nucleus scattering experiment installed in the few-GeV NuMI beam line at Fermilab. In order to study nuclear dependence, MINERνA is endowed with different types of solid nuclear targets as well are liquid targets such as helium and water. This thesis presents measurements of cross-section of antineutrino scattering off nucleons using a variety of solid nuclear targets, carbon, iron, lead and also polystyrene scintillator (CH). The data set of antineutrino used for this analysis was taken between March and July 2010 with a total of 1.60X10 20 protons on target. Charged current inclusive interactions were selected by requiring a positive muon and kinematics limitation of acceptance of the muon spectrometer are applied. The analysis requires neutrino energy between 2GeV et 20GeV and the angle of muon θ m u < 17degree . The absolute cross-section # as function of neutrino energy and the differential cross-section dσ/ dx bj measured and shown the corresponding systematics for each nuclear targets. Data results are compared with prediction of the models implemented in the neutrino events generators GENIE 2.6.2 used by the experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Liquid Scintillation Counting - Packard Triple-Label Calibration

The Radiological Measurements Laboratory (RML) maintains and operates nine Packard Liquid Scintillation Counters (LSCs). These counters were obtained through various sources and were generally purchased as 2500, 2700 or 3100 series counters. In 2004/2005 the software and firmware on the counters were upgraded. The counters are now designated as 3100 series counters running the Quantasmart software package. Thus, a single procedure can be used to calibrate and operate the Packard LSCs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Study of Viability and Challenges of using SiPMs as an Alternative to PMT’s in Scintillation Detectors for Nuclear Safeguards

The goals of this project are to identify fundamental and practical problems and features with SiPMs as they relate to IAEA detector needs, Identify published results and implementations of scintillation detectors tat use SiPMs that are of interest to IAEA, asses how effectively the fundamental problems were addresses, and perform simulations and experiments as needed to reproduce crucial results and make recommendations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗