Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Retrieval of Mid-tropospheric CO2 Directly from AIRS Measurements

We apply the method of Vanishing Partial Derivatives (VPD) to AIRS spectra to retrieve daily the global distribution of CO2 at a nadir geospatial resolution of 90 km x 90 km without requiring a first-guess input beyond the global average. Our retrievals utilize the 15 (micro)m band radiances, a complex spectral region. This method may be of value in other applications, in which spectral signatures of multiple species are not well isolated spectrally from one another.

vanishing partial derivatives↗

High-Order Methods for Computational Fluid Dynamics: A Brief Review of Compact Differential Formulations on Unstructured Grids

Popular high-order schemes with compact stencils for Computational Fluid Dynamics (CFD) include Discontinuous Galerkin (DG), Spectral Difference (SD), and Spectral Volume (SV) methods. The recently proposed Flux Reconstruction (FR) approach or Correction Procedure using Reconstruction (CPR) is based on a differential formulation and provides a unifying framework for these high-order schemes. Here we present a brief review of recent developments for the FR/CPR schemes as well as some pacing items.

Huynh, H. T.↗

Discovery of a Similar to 5 Day Characteristic Timescale in the Kepler Power Spectrum of Zw 229-15

We present time series analyses of the full Kepler dataset of Zw 229− 15. This Kepler light curve- with a baseline greater than three years, composed of virtually continuous, evenly sampled 30-minute measurements - is unprecedented in its quality and precision. We utilize two methods of power spectral analysis to investigate the optical variability and search for evidence of a bend frequency associated with a characteristic optical variability timescale. Each method yields similar results. The first interpolates across data gaps to use the standard Fourier periodogram. The second, using the CARMA-based time-domain modeling technique of Kelly et al., does not need evenly-sampled data. Both methods find excess power at high frequencies that may be due to Kepler instrumental effects. More importantly both also show strong bends (delta alpha is approx. 2) at timescales of approx. 5 days, a feature similar to those seen in the X-ray PSDs of AGN but never before in the optical. This observed approx. 5 day timescale may be associated with one of several physical processes potentially responsible for the variability. A plausible association could be made with light -crossing, dynamical or thermal timescales, depending on the assumed value of the accretion disk size and on unobserved disk parameters such as alpha and H¬R. This timescale is not consistent with the viscous timescale, which would be years in a approx. 10(exp7) solar mass AGN such as Zw 229− 15. However there must be a second bend on long (& 1 year) timescales, and that feature could be associated with the viscous timescale.

timescale↗

Effects of noradrenaline on human vagal baroreflexes

BACKGROUND: Baroreflex sensitivity (BRS) is depressed in conditions associated with high sympathetic nerve activity in proportion to circulating noradrenaline (NA) levels. Despite the prognostic importance of measurements of BRS in patients, there is little information on how high NA levels affect arterial baroreflex function. AIM: To understand better the role of NA in cardiovascular homeostasis. METHODS: We gave incremental intravenous NA infusions (at 50 and 100 ng/kg/min) to 12 healthy young men. We measured RR intervals and photoplethysmographic arterial pressures and estimated BRS with cross-spectral and sequence methods during metronome-guided respiration at 0.25 Hz. RESULTS: The high NA infusion rate significantly increased respiratory-frequency (0.15-0.40 Hz) RR interval spectral power and decreased low-frequency (0.04-0.15 Hz) systolic pressure spectral power compared with baseline levels (P < 0.05 for both). Cross-spectral BRS increased from an average (+/- SD) baseline level of 17.3+/-6.6 to 34.1+/-20.8 ms/mmHg at the high NA infusion rate (P < 0.05). Sequence BRS values did not increase significantly during NA infusions. The percentage of sequences with parallel changes in systolic pressures and RR intervals decreased progressively from a baseline level of 16.0+/-12.9 to 10.1+/-7.4 during the low NA infusion rate and to 6.2+/-6.2% during the high rate (P < 0.05 and 0.01, respectively). CONCLUSIONS: Increases in circulating NA to high physiological levels do not depress BRS but interfere with the close baroreflex-mediated coupling that is usually present between arterial pressure and heart rate.

Non-NASA Center↗

Phase retrieval for short wavelength orbital angular momentum beams using knife-edge diffraction

Laser beams operating in high order transverse modes, especially orbital angular momentum (OAM) modes, have been used increasingly in many frontier research areas. The characterization of these laser modes and the related component analysis can be carried out using the retrieved optical phase. However, conventional iterative phase retrieval methods, when applied to pure OAM modes, may fail because their convergence depends on the choice of the initial phase. Here, we present an improved phase retrieval method which can incorporate additional phase information obtained using knife-edge diffraction. Using no additional optics or few optics available in a wide spectral range, this method is particularly suitable for short wavelength lasers such as free-electron lasers (FELs) in the VUV, EUV, and X-ray regimes. Finally, this method has been tested using simulated beams, and successfully applied to experimentally generated beams from a HeNe laser and an FEL.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calibration to surface reflectance of terrestrial imaging spectrometry data: Comparison of methods

Many algorithms for spectral analysis of imaging spectroscopy data of the Earth's surface require that the data be calibrated to surface reflectance. Calibration requires removing instrumental response, solar irradiance, atmospheric transmittance, and atmospheric scattering from the radiance detected at the sensor. Depending on the amount of support data, this can be a formidable task. This paper examines four methods of calibration: (1) a radiative transfer model from the University of Colorado (ATREM: Gao and Goetz, 1990; Gao et al., 1992), (2) a MODTRAN-based method developed at the Jet Propulsion Lab by Green et al., (1191), (3) a ground calibration using known sites as standards, and (4) a combined approach using radiative transfer methods and ground calibration. Data from the Airborne Visual and Infra-Red Imaging Spectrometer (AVIRIS) instrument were evaluated from data sets obtained over multiple years and multiple sites.

Clark, Roger N.↗

Systems and methods for analyzing building operations sensor data

Systems and methods are disclosed for analyzing building sensor information and decomposing the information therein to a more manageable and more useful form. Certain embodiments integrate energy-based and spectral-based analysis methods with parameter sampling and uncertainty/sensitivity analysis to achieve a more comprehensive perspective of building behavior. The results of this analysis may be presented to a user via a plurality of visualizations and/or used to automatically adjust certain building operations. In certain embodiments, advanced spectral techniques, including Koopman-based operations, are employed to discern features from the collected building sensor data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A new approach for resonance treatment of doubly heterogeneous fuel using the RSE method

A new resonance calculation method for the doubly-heterogeneous (DH) fuels such as high- temperature gas-cooled reactor fuel is proposed based on the resonance calculation based on Spectral Expansion (RSE) method. The concept of pointwise disadvantage factor for fuel grain is taken into account to treat the DH fuels. The verification calculation is carried out for simplified single fuel cell and fuel compact consisting of five fuel cells and graphite moderator. The calculation results indicate that the present method can appropriately handle the space- dependent self-shielding effect for DH fuels. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quantitative uranium elemental reconstruction using spectral x-ray radiography

X-ray radiography offers the ability to noninvasively inspect the internal structure and material composition of objects. Dual-energy radiography allows material discrimination but is limited in quantitative material measurements due to the broad nature of the interrogating x-ray spectrum. Spectral radiography detectors provide an observation of not just the number of x rays that are transmitted through a sample but also the spectrum. Here, experimental validations of a method to use spectral x-ray radiography to accurately quantify the uranium mass in a powder are presented. An accurate system response model was developed, which includes a model of the incident x-ray source spectrum and a pixel-wise detector response that describes how the transmitted x rays were observed. Further, a calibration to account for the effect of partial x-ray attenuation was developed. As a result, the method is demonstrated to be capable of estimating the uranium mass in a variety of uranium oxide powders to a bias of –0.01±0.62%.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Broadband multi-resonant strong field coherence breaking as a tool for single isomer microwave spectroscopy

Using standard hardware available in chirped-pulse Fourier transform microwave (CP-FTMW) spectroscopy, an experimental method is introduced to selectively extract from the microwave spectrum of an otherwise complicated multicomponent mixture a set of transitions due to a single component, thereby speeding spectral assignment. The method operates the broadband chirped-pulse used to excite the sample in the strong-field limit through a combination of high power and control of the sweep rate. A procedure is introduced that leads to selection of three transition frequencies that can be incorporated as a set of resonant sequential single-frequency microwave pulses that follow broadband chirped-pulse excitation, resulting in a reduction in the coherent signal from a set of transitions ascribable to the component of interest. The difference in the CP-FTMW spectrum with and without this set of multi-resonant single-frequency pulses produces a set of transitions that can confidently be assigned to a single component of the mixture, aiding the analysis of its spectrum. In conclusion, the scheme is applied to (i) selectively extract the spectrum of one of five singly 13 C-subsituted isotopologues of benzonitrile in natural abundance, (ii) obtain the microwave spectra of the two structural isomers (E)- and (Z)-phenylvinylnitrile, and (iii) obtain conformer-specific microwave spectra of methylbutyrate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TH-AB-BRA-09: Stability Analysis of a Novel Dose Calculation Algorithm for MRI Guided Radiotherapy

Purpose: To determine the iterative deterministic solution stability of the Linear Boltzmann Transport Equation (LBTE) in the presence of magnetic fields. Methods: The LBTE with magnetic fields under investigation is derived using a discrete ordinates approach. The stability analysis is performed using analytical and numerical methods. Analytically, the spectral Fourier analysis is used to obtain the convergence rate of the source iteration procedures based on finding the largest eigenvalue of the iterative operator. This eigenvalue is a function of relevant physical parameters, such as magnetic field strength and material properties, and provides essential information about the domain of applicability required for clinically optimal parameter selection and maximum speed of convergence. The analytical results are reinforced by numerical simulations performed using the same discrete ordinates method in angle, and a discontinuous finite element spatial approach. Results: The spectral radius for the source iteration technique of the time independent transport equation with isotropic and anisotropic scattering centers inside infinite 3D medium is equal to the ratio of differential and total cross sections. The result is confirmed numerically by solving LBTE and is in full agreement with previously published results. The addition of magnetic field reveals that the convergence becomes dependent on the strength of magnetic field, the energy group discretization, and the order of anisotropic expansion. Conclusion: The source iteration technique for solving the LBTE with magnetic fields with the discrete ordinates method leads to divergent solutions in the limiting cases of small energy discretizations and high magnetic field strengths. Future investigations into non-stationary Krylov subspace techniques as an iterative solver will be performed as this has been shown to produce greater stability than source iteration. Furthermore, a stability analysis of a discontinuous finite element space-angle approach (which has been shown to provide the greatest stability) will also be investigated. Dr. B Gino Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization)

60 APPLIED LIFE SCIENCES↗

Atomistic Assessment of Solute-Solute Interactions during Grain Boundary Segregation

Grain boundary solute segregation is becoming increasingly common as a means of stabilizing nanocrystalline alloys. Thermodynamic models for grain boundary segregation have recently revealed the need for spectral information, i.e., the full distribution of environments available at the grain boundary during segregation, in order to capture the essential physics of the problem for complex systems like nanocrystalline materials. However, there has been only one proposed method of extending spectral segregation models beyond the dilute limit, and it is based on simple, fitted parameters that are not atomistically informed. In this work, we present a physically motived atomistic method to measure the full distribution of solute-solute interaction energies at the grain boundaries in a polycrystalline environment. We then cast the results into a simple thermodynamic model, analyze the Al(Mg) system as a case study, and demonstrate strong agreement with physically rigorous hybrid Monte Carlo/molecular statics simulations. This approach provides a means of rapidly measuring key interactions for non-dilute grain boundary segregation for any system with an interatomic potential.

36 MATERIALS SCIENCE↗

Accurate atmospheric parameters at moderate resolution using spectral indices: Preliminary application to the marvels survey

Studies of Galactic chemical, and dynamical evolution in the solar neighborhood depend on the availability of precise atmospheric parameters (effective temperature T {sub eff}, metallicity [Fe/H], and surface gravity log g) for solar-type stars. Many large-scale spectroscopic surveys operate at low to moderate spectral resolution for efficiency in observing large samples, which makes the stellar characterization difficult due to the high degree of blending of spectral features. Therefore, most surveys employ spectral synthesis, which is a powerful technique, but relies heavily on the completeness and accuracy of atomic line databases and can yield possibly correlated atmospheric parameters. In this work, we use an alternative method based on spectral indices to determine the atmospheric parameters of a sample of nearby FGK dwarfs and subgiants observed by the MARVELS survey at moderate resolving power (R ∼ 12,000). To avoid a time-consuming manual analysis, we have developed three codes to automatically normalize the observed spectra, measure the equivalent widths of the indices, and, through a comparison of those with values calculated with predetermined calibrations, estimate the atmospheric parameters of the stars. The calibrations were derived using a sample of 309 stars with precise stellar parameters obtained from the analysis of high-resolution FEROS spectra, permitting the low-resolution equivalent widths to be directly related to the stellar parameters. A validation test of the method was conducted with a sample of 30 MARVELS targets that also have reliable atmospheric parameters derived from the high-resolution spectra and spectroscopic analysis based on the excitation and ionization equilibria method. Our approach was able to recover the parameters within 80 K for T {sub eff}, 0.05 dex for [Fe/H], and 0.15 dex for log g, values that are lower than or equal to the typical external uncertainties found between different high-resolution analyses. An additional test was performed with a subsample of 138 stars from the ELODIE stellar library, and the literature atmospheric parameters were recovered within 125 K for T {sub eff}, 0.10 dex for [Fe/H], and 0.29 dex for log g. These precisions are consistent with or better than those provided by the pipelines of surveys operating with similar resolutions. These results show that the spectral indices are a competitive tool to characterize stars with intermediate resolution spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Python catemis package for DARHT Axis-II Dispenser-Cathode Emissivity and Temperature Analysis

The catemis python package includes the analysis methods used in paper "DARHT Axis-II Dispenser-Cathode Emissivity and Temperature", which was presented at the 2021 Weapons Engineering Symposium and Journal (WESJ) hosted by Los Alamos National Laboratory. The paper (LA-UR-21-25647) and presentation (LA-UR-21-28231) report on a temperature and emissivity model that has been developed and applied to data from diagnostics used to measure the surface temperature of the DARHT Axis-II hot dispenser cathode over more than a decade of operation. The catemis package provides all the methods used in reporting these results along with the data files used to create the plots and tables in the paper. This includes methods for loading and processing FAR spectral pyrometer data along with methods for temperature calibration of cathode images.

Koglin, Jason↗

Multiplexed ultrasonic system

A system which rapidly determines the elastic stiffness constants of materials in plate shape as well as characterize material flaws that are affecting these constants. Rapid (below a minute) nondestructive evaluation system allow for the determination of material stiffness constants, low noise data acquisition algorithm for measuring spectral data. A real time method of displaying leaky Lamb wave spectral data.

Bar-Cohen, Yoseph↗

Ground level reflectance measurement techniques - An evaluation with emphasis on the importance of spectral calibration

The bandpasses, overflight conditions, and sensor geometry that will provide optimum target discrimination in remote-sensing studies can be determined only from spectral reflectance measurements made for various sun-target-sensor geometries, supplemented by model calculations which can be checked against field data. The accurate measurement of ground reflectance properties is critical to the design of future sensors and to the determination of imaging conditions. The current investigation has the objective to review typical methods of measuring spectral reflectance, to point out some of the problems inherent to reflectance measuring techniques, and to present a method of checking measurement accuracy.

Duggin, M. J.↗

Optimizing spectral phase transfer in four-wave mixing with gas-filled capillaries

Four-wave mixing (FWM) in gas-filled hollow-core capillaries, a nonlinear optical process that mixes signal and pump photon frequencies to generate idler frequency photons, offers a method for precise spectral phase transfer from signal to idler at ultrashort timescales and extreme powers. However, this regime is challenged by competing linear and nonlinear dynamics, leading to significant trade-offs between spectral phase transfer and conversion efficiency. Our computational investigation focuses on the upconversion of femtosecond pulses from the infrared (IR) to the ultraviolet (UV), a range notoriously difficult to manipulate. We explore an intermediate energy regime that strikes an optimal balance between FWM-mediated phase-transfer fidelity and nonlinear conversion efficiency. By adjusting the energy ratios and spectral phase profiles of the input signal, we achieve conversion efficiencies of approximately 5-15% while maintaining an effective quasi-linear spectral phase transfer. These findings will contribute to establishing first-principles and scaling laws essential for applications such as high-precision imaging, spectroscopy, quantum transduction, and distributed entangled interconnects, facilitating advanced control of ultrafast photonic and electronic wavepackets in quantum materials with unprecedented spatial and temporal precision.

Zhang, Hao↗

High-resolution single-shot spectral monitoring of hard x-ray free-electron laser radiation

We have developed an on-line spectrometer for hard x-ray free-electron laser (XFEL) radiation based on a nanostructured diamond diffraction grating and a bent crystal analyzer. Our method provides high spectral resolution, interferes negligibly with the XFEL beam, and can withstand the intense hard x-ray pulses at high repetition rates of >100 Hz. The spectrometer is capable of providing shot-to-shot spectral information for the normalization of data obtained in scientific experiments and optimization of the accelerator operation parameters. We have demonstrated these capabilities of the setup at the Linac Coherent Light Source, in self-amplified spontaneous emission mode at full energy of >1 mJ with a 120 Hz repetition rate, obtaining a resolving power of Ε/δΕ > 3 × 10 4 . In conclusion, the device was also used to monitor the effects of pulse duration down to 8 fs by analysis of the spectral spike width.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗