Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Simulation of Line Profiles of the Krypton Spectra Emitted by the Plasma of Current Sheets

Line profiles of the krypton spectra emitted by the plasma of current sheets are simulated. Current sheets are formed under the impact of magnetic fields with singular X-lines. The spectral line profiles are calculated by the method of the energy matrix diagonalization of an atom in an electric field. The dependence of the behavior of the line profiles on the parameters of an alternating electric field arising inside the plasma of current sheets and the dependence of these profiles on the plasma temperature are investigated. The criteria which allow one to reveal spectral lines serving as the indicators of the appearance of anomalous electric fields inside current sheets are suggested.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A conservative, thermodynamically consistent numerical approach for low Mach number combustion. Part I: Single-level integration

Here we present a numerical approach for low Mach number combustion that conserves both mass and energy while remaining on the equation of state to a desired tolerance. We present both unconfined and confined cases, where in the latter the ambient pressure changes over time. Our overall scheme is a projection method for the velocity coupled to a multi-implicit spectral deferred corrections (SDC) approach to integrate the mass and energy equations. The iterative nature of SDC methods allows us to incorporate a series of pressure discrepancy corrections naturally that lead to additional mass and energy influx/outflux in each finite volume cell in order to satisfy the equation of state. The method is second order, and satisfies the equation of state to a desired tolerance with increasing iterations. Motivated by experimental results, we test our algorithm on hydrogen flames with detailed kinetics. We examine the morphology of thermodiffusively unstable cylindrical premixed flames in high-pressure environments for confined and unconfined cases. We also demonstrate that our algorithm maintains the equation of state for premixed methane flames and non-premixed dimethyl ether jet flames.

97 MATHEMATICS AND COMPUTING↗

Effect of laser spectral bandwidth on coherent control of resonance-enhanced multiphoton-ionization photoelectron spectroscopy

The high-resolution (2 + 1) resonance-enhanced multiphoton-ionization photoelectron spectroscopy (REMPI-PS) can be obtained by measuring the photoelectron intensity at a given kinetic energy and scanning the single π phase step position. In this paper, we further demonstrate that the high-resolution (2 + 1) REMPI-PS cannot be achieved at any measured position of the kinetic energy by this measurement method, which is affected by the laser spectral bandwidth. We propose a double π phase step modulation to eliminate the effect of the laser spectral bandwidth, and show the advantage of the double π phase step modulation on achieving the high-resolution (2 + 1) REMPI-PS by considering the contributions involving on- and near-resonant three-photon excitation pathways.

74 ATOMIC AND MOLECULAR PHYSICS↗

Electron scattering on A = 3 nuclei from quantum Monte Carlo based approaches

We perform first-principle calculations of electron-nucleus scattering on 3 He and 3 H using the Green's function Monte Carlo method and two approaches based on the factorization of the final hadronic state: the spectral-function formalism and the short-time approximation. These three methods are benchmarked among each other and compared to the experimental data for the longitudinal and transverse electromagnetic response functions of 3 He, and the inclusive cross sections of both 3 He and 3 H. Since these three approaches are based on the same description of nuclear dynamics of the initial target state, comparing their results enables a precise quantification of the uncertainties inherent to factorization schemes. At sufficiently large values of the momentum transfer, we find an excellent agreement of the Green's function Monte Carlo calculation with experimental data and with both the spectral-function formalism and the short-time approximation. Here, we also analyze the relevance of relativistic effects, whose inclusion becomes crucial to explain data at high momentum and energy transfer.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electron scattering on ${\mathbf{A=3}}$ nuclei from quantum Monte Carlo based approaches

We perform first-principle calculations of electron-nucleus scattering on $^3$He and $^3$H using the Green's function Monte Carlo method and two approaches based on the factorization of the final hadronic state: the spectral-function formalism and the short-time approximation. These three methods are benchmarked among each other and compared to the experimental data for the longitudinal and transverse electromagnetic response functions of $^3$He, and the inclusive cross sections of both $^3$He and $^3$H. Since these three approaches are based on the same description of nuclear dynamics of the initial target state, comparing their results enables a precise quantification of the uncertainties inherent to factorization schemes. At sufficiently large values of the momentum transfer, we find an excellent agreement of the Green's function Monte Carlo calculation with experimental data and with both the spectral-function formalism and the short-time approximation. We also analyze the relevance of relativistic effects, whose inclusion becomes crucial to explain data at high momentum and energy transfer.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection of Gaseous Plumes using Basis Vectors

Detecting and identifying weak gaseous plumes using thermal imaging data is complicated by many factors. There are several methods currently being used to detect plumes. They can be grouped into two categories: those that use a chemical spectral library and those that don’t. The approaches that use chemical libraries include least squares methods and physics-based approaches. They are "optimal" only if the plume chemical is actually in the search set but risk missing chemicals not in the library. The methods that don’t use a chemical spectral library are based on a statistical or data analytical transformation applied to the data. These include principle components, independent components, entropy, Fourier transform, and others. These methods do not explicitly take advantage of the physics of the signal formulation process and therefore don’t exploit all available information in the data. This paper presents initial results of employing basis vectors as a tool for plume detection. It describes the standard generalized least squares approach using gas spectra, presents the detection approach using basis vectors, and compares detection images resulting from applying both methods to synthetic hyperspectral images.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SCEC/USGS Community Stress-Drop Validation Study: How Spectral Fitting Approaches Influence Measured Source Parameters

Spectral source parameters used to estimate an earthquake’s stress drop (⁠Δσ⁠) can vary significantly across measurement approaches. The Statewide California Earthquake Center/U.S. Geological Survey Community Stress‐Drop Validation Study was initiated to compare source parameter estimates, focusing initially on a dataset from the 2019 Ridgecrest earthquake sequence. As part of that validation effort, here we focus on one potential source of uncertainty: whether spectral fitting approaches alone, applied to a common set of spectra from the 2019 Ridgecrest sequence result in different source parameter estimates. By using a common set of benchmark spectra analyzed across a consistent frequency band of 1–40 Hz, we eliminate many sources of variability. A subgroup of validation study participants volunteered to estimate the low‐frequency displacement (⁠Ω 0 ⁠) and corner frequency (⁠ƒ c ⁠) by fitting a smooth function to benchmark displacement spectra. Participants used linear‐ or log‐sampled spectra, assumed a Brune or Boatwright spectral model, and applied different misfit criteria. We compare 17 approaches used to estimate ⁠Ω 0 ⁠, ƒ c ⁠, and Δσ for 54 earthquake spectra. Our results reveal that 35% of events have Δσ estimates within a factor of two, whereas others exhibit variations exceeding an order of magnitude. The variability in and can largely be attributed to whether a spectrum is consistent with the smooth function of an idealized simple crack model. The trade‐off between Ω 0 and ƒ c may be more pronounced when using linearly sampled spectra, as higher frequency spectral bumps control the fits. As expected, methods that assumed a Boatwright model tended to have lower Ω 0 and somewhat higher ƒ c compared to those assuming a Brune model, although resulting Δσ estimates are similar. Finally, when compared to the overall validation study results, the fitting approach alone may account for between 5% and 90% (25% on average) of the total variability in spectral Δσ⁠.

58 GEOSCIENCES↗

Unveiling Hidden Shake-Up Features in the Uranyl M 4 -Edge Spectrum

The M 4,5 -edge high energy resolution X-ray absorption near-edge structure (HR-XANES) spectra of actinyls offer valuable insights into the electronic structure and bonding properties of heavy-element complexes. To conduct a comprehensive spectral analysis, it is essential to employ computational methods that accurately account for relativistic effects and electron correlation. In this work, we utilize variational relativistic multireference configurational interaction methods to compute and analyze the X-ray M 4 -edge absorption spectrum of uranyl. By employing these advanced computational techniques, we achieve excellent agreement between the calculated spectral features and experimental observations. Moreover, the calculations unveil significant shake-up features, which arise from the intricate interplay between strongly correlated 3d core-electron and ligand excitations. This research provides important theoretical insights into the spectral characteristics of heavy-element complexes. Furthermore, it establishes the foundation for utilizing M 4,5 -edge spectroscopy as a means to investigate the chemical activities of such complexes. By leveraging this technique, we can gain a deeper understanding of the bonding behavior and reactivity of heavy-element compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dataset describing two reference models for full-spectral lighting and daylight simulations together with implementations for two software systems

A dataset of two spectral lighting simulation reference models - one office and one factory hall - is presented. It aims to demonstrate and support full-spectral daylight and electric lighting simulations and facilitate evaluation of non-visual effects of light. The dataset includes Rhino CAD geometry, comprehensive spectral material and light source data and window system BSDF data. Example implementations in the two software tools, Radiance and OWL, enable reproducible workflows and support adoption in other software. The dataset is openly available on Zenodo. The office model reproduces Room 518 at the University of Innsbruck, including a west-facing façade and interior furnishings. The factory hall model follows the proposed geometry in the European standard 15193 for building energy performance. Interior reflectances in the office were measured in-situ using a handheld spectrometer. Exterior spectra and factory hall materials matching specified reflectances were obtained from an online spectral materials database. Glazing transmittance was derived from IGDB data using LBNL Optics/WINDOW. BSDFs for venetian blinds at various tilt angles, and for a diffusing pane adapted from the Complex Glazing Database, were generated in WINDOW. Luminaires in both models are specified with photometric files (Eulumdat/IES) and lamp spectra (Fluorescent 840, 4000 K LED). The provided example implementations (Radiance, OWL) include prepared input data and scripts to run first spectral simulations; example results are also included. The dataset is prepared to support reuse by researchers, designers and software developers for method validation, software engineering and comparison, and development of spectral metrics and controls.

Geisler-Moroder, David↗

TU-CD-207-01: Characterization of Breast Tissue Composition Using Spectral Mammography

Purpose: To investigate the feasibility of characterizing the chemical composition of breast tissue, in terms of water and lipid, by using spectral mammography in simulation and postmortem studies. Methods: Analytical simulations were performed to obtain low- and high-energy signals of breast tissue based on previously reported water, lipid, and protein contents. Dual-energy decomposition was used to characterize the simulated breast tissue into water and lipid basis materials and the measured water density was compared to the known value. In experimental studies, postmortem breasts were imaged with a spectral mammography system based on a scanning multi-slit Si strip photon-counting detector. Low- and high-energy images were acquired simultaneously from a single exposure by sorting the recorded photons into the corresponding energy bins. Dual-energy material decomposition of the low- and high-energy images yielded individual pixel measurements of breast tissue composition in terms of water and lipid thicknesses. After imaging, each postmortem breast was chemically decomposed into water, lipid and protein. The water density calculated from chemical analysis was used as the reference gold standard. Correlation of the water density measurements between spectral mammography and chemical analysis was analyzed using linear regression. Results: Both simulation and postmortem studies showed good linear correlation between the decomposed water thickness using spectral mammography and chemical analysis. The slope of the linear fitting function in the simulation and postmortem studies were 1.15 and 1.21, respectively. Conclusion: The results indicate that breast tissue composition, in terms of water and lipid, can be accurately measured using spectral mammography. Quantitative breast tissue composition can potentially be used to stratify patients according to their breast cancer risk.

60 APPLIED LIFE SCIENCES↗

Explosion Discrimination Using Seismic Gradiometry and Spectral Filtering of Data

Here, we present a new method to discriminate between earthquakes and buried explosions using observed seismic data. The method is different from previous seismic discrimination algorithms in two main ways. First, we use seismic spatial gradients, as well as the wave attributes estimated from them (referred to as gradiometric attributes), rather than the conventional three-component seismograms recorded on a distributed array. The primary advantage of this is that a gradiometer is only a fraction of a wavelength in aperture compared with a conventional seismic array or network. Second, we use the gradiometric attributes as input data into a machine learning algorithm. The resulting discrimination algorithm uses the norms of truncated principal components obtained from the gradiometric data to distinguish the two classes of seismic events. Using high-fidelity synthetic data, we show that the data and gradiometric attributes recorded by a single seismic gradiometer performs as well as a conventional distributed array at the event type discrimination task.

58 GEOSCIENCES↗

In vivo spectral micro-imaging of tissue

In vivo endoscopic methods an apparatuses for implementation of fluorescence and autofluorescence microscopy, with and without the use of exogenous agents, effectively (with resolution sufficient to image nuclei) visualize and categorize various abnormal tissue forms.

60 APPLIED LIFE SCIENCES↗

Smoothed aggregation adaptive spectral element-based algebraic multigrid

SAAMGE provides parallel methods for building multilevel hierarchies and solvers that can be used for elliptic equations with highly heterogeneous coefficients. Additionally, hierarchy adaptation is implemented allowing solving multiple problems with close coefficients without rebuilding the hierarchy.

Source record↗

Morpheus Spectral Counter: A computational tool for label-free quantitative mass spectrometry using the Morpheus search engine

Label-free quantitative MS based on the Normalized Spectral Abundance Factor (NSAF) has emerged as a straightforward and robust method to determine the relative abundance of individual proteins within complex mixtures. Here, we present Morpheus Spectral Counter (MSpC) as the first computational tool that directly calculates NSAF values from output obtained from Morpheus, a fast, open-source, peptide-MS/MS matching engine compatible with high-resolution accurate-mass instruments. NSAF has distinct advantages over other MS-based quantification methods, including a higher dynamic range as compared to isobaric tags, no requirement to align and re-extract MS1 peaks, and increased speed. MSpC features an easy to use graphic user interface that additionally calculates both distributed and unique NSAF values to permit analyses of both protein families and isoforms/proteoforms. MSpC determinations of protein concentration were linear over several orders of magnitude based on the analysis of several high-mass accuracy datasets either obtained from PRIDE or generated with total cell extracts spiked with purified Arabidopsis 20S proteasomes. Lastly, the MSpC software was developed in C# and is open sourced under a permissive license with the code made available at http://dcgemperline.github.io/Morpheus_SpC/.

59 BASIC BIOLOGICAL SCIENCES↗

TU-EF-204-12: Quantitative Evaluation of Spectral Detector CT Using Virtual Monochromatic Images: Initial Results

Purpose To evaluate the image quality and spectral information of a spectral detector CT (SDCT) scanner using virtual monochromatic (VM) energy images. Methods The SDCT scanner (Philips Healthcare) was equipped with a dual-layer detector and spectral iterative reconstruction (IR), which generates conventional 80–140 kV polychromatic energy (PE) CT images using both detector layers, PE images from the low-energy (upper) and high-energy (lower) detector layers and VM images. A solid water phantom with iodine (2.0–20.0 mg I/ml) and calcium (50.0–600.0 mg Ca/ml) rod inserts was used to evaluate effective energy estimate (EEE) and iodine contrast to noise ratio (CNR). The EEE corresponding to an insert CT number in a PE image was calculated from a CT number fit to the VM image set. Since PE image is prone to beam-hardening artifact EEE may underestimate the actual energy separation from two layers of the detector. A 30-cm-diameter water phantom was used to evaluate noise power spectrum (NPS). The phantoms were scanned at 120 and 140 kV with the same CTDIvol. Results The CT number difference for contrast inserts in VM images (50–150 keV) was 1.3±6% between 120 and 140 kV scans. The difference of EEE calculated from low- and high-energy detector images was 11.5 and 16.7 keV for 120 and 140 kV scans, respectively. The differences calculated from 140 and 100 kV conventional PE images were 12.8, and 20.1 keV from 140 and 80 kV conventional PE images. The iodine CNR increased monotonically with decreased keV. Compared to conventional PE images, the peak of NPS curves from VM images were shifted to lower frequency. Conclusion The EEE results indicates that SDCT at 120 and 140 kV may have energy separation comparable to 100/140 kV and 80/140 kV dual-kV imaging. The effects of IR on CNR and NPS require further investigation for SDCT. Author YY and AD are Philips Healthcare employees.

60 APPLIED LIFE SCIENCES↗

Effective properties of semitransparent radiative cooling materials with spectrally variable properties

Radiative cooling is a promising solid-state, non-vapor-compression technology for passive refrigeration and air conditioning. Although this phenomenon occurs naturally, achieving a significant amount of cooling to make it a technically and economically viable technology requires highly engineered, spectrally selective radiative surfaces. These characteristics make radiative cooling difficult to estimate, particularly when it is integrated with other systems such as photovoltaic panels or building envelopes. The complexity further increases when the substrate also participates in the radiative cooling (along with the radiative coating). Energy estimation is becoming increasingly critical because of the recent focus on the semitransparent radiative coatings that transmit a variety of colors to enhance the aesthetic appeal of the system. In this work, we propose an iterative method to calculate the effective radiative properties, which provides the same net radiative cooling that would be observed using the spectral properties at both the coating and substrate surfaces. Compared to traditional methods that rely on either computationally expensive full spectral analysis or methods for averaging each radiative surface parameter locally, our proposed method focuses on calculating effective properties that provide the same the net cooling effect as a full spectral analysis by accounting the emissivity, absorptivity, and transmissivity collectively, thereby providing an overall estimation error of less than 0.2%. We believe that this study will be beneficial to the engineering communities that employ complex simulation codes and require lumped solar and thermal radiation related parameters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Practical Guide to Chemometric Analysis of Optical Spectroscopic Data

The methodology and mathematical treatment of several classic multivariate methods for the analysis of spectroscopic data is demonstrated in a straightforward way that can be used as a basis for teaching an undergraduate introductory course on chemometric analysis. The multivariate techniques of classical least squares (CLS), principal component regression (PCR), and partial least squares (PLS), as well as the univariate Beer’s law method have been described and compared, building students’ understanding by starting with the univariate method and progressing step by step into the multivariate methods. Equations for the production of regression vectors from training set spectral data is described and their use demonstrated for the prediction of constituent concentrations on a separate validation set of spectra. Extreme care is taken to ensure consistency in variable formatting of data matrices. This provides a key foundation to understanding how spectral data are manipulated using these different mathematical approaches for building quantitative regression models. Each method is applied to a real-world data set, and the results are discussed to show students the types of information that can be gleaned from each method. A training set comprised of 20 infrared absorbance spectra containing 3 constituents (benzene, polystyrene, and gasoline) of known composition are used to demonstrate the matrix operations for each regression method. A separate set of 12 real-world napalm samples (containing benzene, polystyrene and gasoline) are used as a validation set to demonstrate the ability to utilize the regression models on an unknown dataset. A toolbox (PNNL Chemometric Toolbox) written in MATLAB language is supplied in the Supplemental Information file and can be used as a companion for understanding the development and deployment of the chemometric algorithms described in this paper. The datasets of the infrared spectra are also supplied, allowing users to build and inspect the chemometric models on their own. Finally, the Toolbox includes scripts to assist users in loading their own datasets into MATLAB and performing CLS, PCR, and PLS on their data.

Upper-Division Undergraduate, Analytical Chemistry↗

A simple method of measuring the effective SRS coefficient in single-mode optical fibres and its applicability limits

This paper describes techniques for measuring the SRS coefficient in a wide spectral range, including the region of small Stokes shifts. A simple, approximate method is proposed for evaluating the SRS coefficient near a gain peak. Spectral dependences of the SRS coefficient are presented for various telecom fibres. (nonlinear optical phenomena)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗