Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stabilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Inverter Intensive Hybrid Power Plant Modeling with Small-Signal Stability Augmentation through Flexible Operation Mode Transition

Hybrid power plants (HPPs) prompt the penetration of inverter-based renewable energy sources (RES) in transmission systems; however, given their low-inertia nature, HPPs are dominated by power electronic inverters, so there are inevitable challenges in system stability when increasing numbers of HPPs are integrated into the modern power grids. To boost the penetration level of HPPs without jeopardizing system stability, it is desirable to equip them with operational characteristics (i.e., grid-forming capabilities) that are comparable to those of conventional power plants dominated by synchronous generators (SGs). In this paper, a holistic model of inverter intensive HPP is derived and a bi-level hierarchical control is developed to allow HPPs to flexibly switch among the designed operation modes (i.e., P-Q, P-V, and isochronous modes). Compared to SGs, which have limited controllability, the operation mode of each HPP could vary as requested. Such flexible mode transitions could be integrated into the secondary plant-level control and be leveraged as an additional control degree to further augment system stability. Further, the system small-signal stability margin is quantified with varying HPP operation modes. More importantly, modal analysis is thereby conducted to quantify the impacts of mode transition on the system oscillatory modes. The effectiveness of the proposed HPP bi-level hierarchical control is verified using extensive case studies based on the simplified real-world island power grid, and the results validate that the system small-signal stability margin can be enhanced with the additional degree of control flexibility enabled by HPP operation mode transition. The real-time hardware-in-the-loop (HIL) results are also provided to verify the proposed method.

grid-forming control↗

Developing Frequency Stability Constraint for Unit Commitment Problem Considering High Penetration of Renewables

As zero-carbon electricity systems become the trend of future grid, the system inertia provided by conventional synchronous generators (SGs) keeps decreasing. The resultant lower system inertia will inevitably cause frequency stability problem, especially in the first few seconds following disturbance. To tackle this challenge, this paper proposes a frequency stability constraint for power systems unit commitment problem by considering the fast frequency responses (FFRs) from inverter-based resources (IBRs). Our developed frequency stability constraint is grounded on an analytical frequency nadir estimation framework that considers both SG and IBR dynamics. The accuracy of our frequency nadir estimation framework is validated by most severe N-1 contingency simulation result in a real island system. Then, the adaptive inertia frequency stability constraint is derived by performing sensitivity analysis with our frequency nadir estimation framework. Finally, we demonstrate the effectiveness of our developed frequency stability constraint with one year day-ahead unit commitment results of the island system.

fast frequency response↗

Optimal Power Flow in DC Networks with Robust Feasibility and Stability Guarantees

With high penetrations of renewable generation and variable loads, there is significant uncertainty associated with power flows in DC networks such that stability and operational constraint satisfaction are of concern. Most existing DC network optimal power flow (DN-OPF) formulations assume exact knowledge of loading conditions and do not provide stability guarantees. Here, in contrast, this paper studies a DN-OPF formulation which considers both stability and operational constraint satisfaction under uncertainty. The need to account for a range of uncertainty realizations in this paper's robust optimization formulation results in a challenging semi-infinite program (SIP). The proposed solution algorithm reformulates this SIP into a computationally tractable problem by constructing a tight convex inner approximation of the stability set using sufficient conditions for the existence of a feasible and stable power flow solution. Optimal generator set-points are obtained by optimizing over the proposed convex stability set. The validity and effectiveness of the propose algorithm is demonstrated through various DC networks adapted from IEEE test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient Stability Analysis for Offshore Wind Power Plant Integration Planning Studies - Part II: Long Term Faults

Here, this paper addresses the transient stability (also called large-signal stability) analysis of power systems for offshore wind power plant integration planning studies. In particular, this study develops a comprehensive practical methodology to assess transient stability of power systems, including rotor angle stability, voltage stability, and frequency response for large scale power systems. This methodology considers variability of the offshore wind power plants as well as the type of any faulted system' components present and is applicable to the study of both short term and long term faults. Part I of this research discussed the short term faults whereas as Part II, the present paper, discusses long term faults. This research considers the integration of offshore wind power plants into existing power systems and demonstrates the utility of this methodology through the examination of the specific case of integrating 1,000 MW of offshore wind power into the FirstEnergy/PJM service territory using a realistic model of 63k-bus test system that represents the U.S. Eastern Interconnection.

17 WIND ENERGY↗

Transient Stability Analysis for Offshore Wind Power Plant Integration Planning Studies - Part I: Short Term Faults

Power system planning is the process of forecasting load demand and ensuring sufficient generation and reserve capacities over some planning horizon. This process includes investigation of steady-state and dynamic operation of power system of interest. This paper addresses the transient stability (also known as large-signal stability) analysis of power systems for offshore wind power plant integration planning studies. In particular, this study develops a comprehensive practical methodology to assess transient stability of power systems, including rotor angle stability, voltage stability and frequency response for all fault types for large scale power systems. This methodology considers variability of the offshore wind power plants as well as the type of any faulted components present and is applicable to the study of both short term and long term faults, though only short term faults are considered here (long term faults are treated sequentially in a companion paper). Furthermore, this paper considers the integration of offshore wind power plants into existing power systems and demonstrates the utility of this methodology through the examination of the specific case of integrating 1,000MW of offshore wind power into the FirstEnergy/PJM service territory using a realistic model of 63k-bus test system that represents the U.S. Eastern Interconnection.

17 WIND ENERGY↗

Small-Signal Stability of Grid-Forming Converters Under Fault Conditions

Threshold virtual impedance (TVI)-based current limiting for grid-forming converters (GFMs) has gained great interest due to its ability to maintain voltage source behaviour during faults. However, sequence component extraction (SCE) and negative-sequence control (NSC) are often overlooked in small-signal stability assessments during faults. This paper develops small-signal sequence impedance models for GFMs under four well-known SCE methods based on TVI current limiting control during symmetrical fault conditions. Using the developed impedance models, the impacts of SCE and NSC, and the voltage and current control loop bandwidths, on system stability during faults are investigated. Additionally, since negative-sequence TVI (TVI-) is typically added along with its positive-sequence counterpart, which is often inductive, inductive and resistive TVI- are examined. The findings suggest that a higher voltage or current control loop bandwidth has a negative impact on system stability, while SCE and NSC largely reduce the stable range for voltage and current control loop bandwidth during faults, and that the severity of such impacts is determined by the particular SCE method. Furthermore, it is observed that inductive TVI- significantly degrades system stability, while resistive TVI- can enhance stability when suitable SCE methods are appropriately selected and designed. Matlab/Simulink electromagnetic transient simulations validate these analytical results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterization of Impedance and Stability for Doubly-Fed Induction Generator Based on Voltage-Modulated Direct Power Control

Voltage-modulated direct power control (VM-DPC) applied to the doubly-fed induction generator (DFIG) offers superior steady-state and transient performance but remains underexplored for suppressing wideband oscillations. Here, this article proposes a comprehensive impedance for the VM-DPC-based DFIG, analyzing its impedance characteristics and stability mechanisms compared with the DFIG based on vector-oriented control (VOC). The unified power transfer function is defined for DFIGs employing VM-DPC or VOC to ensure consistent comparison benchmarks. The comprehensive impedance of VM-DPC-based DFIG, incorporating mechanical and grid-side converter (GSC) dynamics, is derived using complex vector modeling in the αβ -frame. Furthermore, the influence of VM-DPC parameters and grid strength on the stability of grid-connected DFIG systems is assessed through eigenvalue trajectory analysis. Impedance analysis reveals the significant contributions of mechanical and GSC dynamics to DFIG impedance, as well as the narrower frequency range of negative resistance in the VM-DPC-based DFIG compared to the VOC-based DFIG. Stability analysis identifies the VM-DPC parameters of the rotor-side converter as dominant factors affecting system stability and confirms that the VM-DPC-based DFIG achieves better stability under weak grid conditions than its VOC-based counterpart. These findings are validated through simulations and experiments.

42 ENGINEERING↗

Tri-Sectional Approximation of the Shortest Path to Long-Term Voltage Stability Boundary with Distributed Energy Resources

Ensuring long-term voltage stability is critical for reliable operations of power grids. High share of distributed energy resources (DERs) can create complicated system operation modes that may invalidate the traditional long-term voltage stability analysis based on typical operation modes. To address this challenge, this paper investigates how to compute the shortest path to the voltage stability boundary in the DER aggregated load space with large dispersion. Instead of working in the Euclidean space, we establish the analysis and computations on the algebraic power flow manifold to better capture the curvature change of the shortest path along the direction of losing stability. A modified optimal control framework is presented for obtaining the ground-truth of the smooth shortest path on the manifold. To efficiently and accurately solve for the shortest path, we further leverage the geometric features of the power flow manifold and propose a tri-sectional approximation model that is scalable for large-scale systems. Several numerical examples, up to the 1354-bus system, with different DER penetration levels and high dimensional renewable power injection variations are evaluated. The simulation results demonstrate that the tri-sectional approximation achieves high accuracy and efficiency to approximate the shortest path to the voltage stability boundary.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage Stability Constrained Moving Target Defense Against Net Load Redistribution Attacks

Moving target defense (MTD) using distributed flexible AC transmission system (D-FACTS) devices is a promising defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation. However, all existing studies myopically perturb the reactance of D-FACTS lines without considering the system voltage stability. In this paper, we first illustrate voltage instability induced by MTDs in a three-bus system. To address this issue, we further propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow and voltage stability indices. We mathematically derive the sensitivity matrix of voltage stability index to line impedance, on which an optimization problem for maximizing voltage stability index is formulated. This framework is tested on the IEEE 14-bus and the IEEE 118-bus transmission systems, in which net load redistribution attacks are launched by sophisticated attackers. Here, the simulation results show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. We conduct case studies with and without the proposed framework under different MTD planning and operational methods. The impacts of the proposed two methods on attack detection effectiveness and system economic metrics are also revealed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Site Disorder as a Predictor for Compositionally Complex 5RE 2 Zr 2 O 7 Ceramic Phase Stability

Here, phase formation and stability of five component compositionally complex rare earth zirconates (5RE 2 Zr 2 O 7 ) were investigated by X-ray diffraction and electron microprobe analysis. Zirconates with different rare earth compositions (LaNdSmEuDy, LaNdSmEuYb, LaNdEuErYb, LaNdDyErYb, SmEuDyYHo, LaYHoErYb, and DyYHoErYb) were synthesized at 1700°C and 2000°C by the solid-state method to investigate the effect of A-site site disorder (δ A ) on phase stability. Increased site disorder results from mixed cation occupancy with localized crystallographic strain and bond disorder. Compositions LaNdSmEuDy (δ A = 4.6) and LaNdSmEuYb (δ A = 6.0) produced a single pyrochlore phase and compositions SmDyYHoErYb (δ A = 2.8), LaYHoErYb (δ A = 6.2), and DyYHoErYb (δ A = 1.7) produced a single fluorite phase. High δ A compositions LaNdEuErYb (δ A = 6.9) and LaNdDyErYb (δ A = 7.2) produced a pyrochlore and fluorite phase mixture at 1700°C. Single phase was obtained for the latter composition at 2000°C. Of the single phase compositions calcined at 1700°C, LaNdSmEuYb and LaYHoErYb (both with largest δ A ) showed decomposition to mixed fluorite and pyrochlore phases during lower temperature anneals, indicating entropic stabilization. Comparison with prior work shows a temperature dependence of the critical δ A for phase stability, and compositions near it are expected to be entropy stabilized.

36 MATERIALS SCIENCE↗

Temporal signal stability of KCl:Eu{sup 2+} storage phosphor dosimeters

Purpose: Current KCl:Eu{sup 2+} prototype dosimeters require a wait time of 12 h between irradiation and dosimetric readout. Although irradiating the dosimeters in the evening and reading on the following day works well in the clinical schedule, reducing the wait time to few hours is desirable. The purposes of this work are to determine the origin of the unstable charge-storage centers and to determine if these centers respond to optical or thermal excitation prior to dosimetric readout. Methods: Pellet-style KCl:Eu{sup 2+} dosimeters were fabricated in-house for this study. A 6 MV photon beam was used to irradiate the dosimeters. After x ray irradiation, dosimeters were subjected to external excitation with near-infrared (NIR) light, ultraviolet (UV) light, or thermal treatment. Photostimulated luminescence (PSL) signal's temporal stability was subsequently measured at room temperature over a few hours using a laboratory PSL readout system. The dosimeters were also placed in a cryostat to measure the temperature dependence of the temporal stability down to 10 K. Results: Strong F-band was present in the PSL stimulation spectrum, indicating that F-centers were the electron-storage centers in KCl:Eu{sup 2+} where an electron was stored at a chlorine anion vacancy. Due to deep energy-depth (2.2 eV), F-centers were probably not responsible for the fast fading in the first a few hours post x ray irradiation. In addition, weak NIR bands were present. However, there was no change in PSL stabilization rate with intense NIR excitation, suggesting that the NIR bands played no role in the PSL fading. At temperatures lower than 77 K there was almost no signal fading with time. Noticeable PSL was observed for undoped KCl samples at room temperature, suggesting that Cl{sub 2}{sup -} V{sub k} centers served as hole-storage centers for both undoped and doped KCl where a hole was trapped by a chlorine molecular ion. V{sub k} centers were stable at low temperature and became mobile at room temperature, probably causing the observed PSL fading with time. On the other hand, V{sub k} center could be stabilized by Eu{sup 2+} activator or oxygen in the lattice, leading to the stable component in the PSL. A thermal process at elevated temperatures (60 Degree-Sign C or higher) was able to significantly accelerate the migration process resulting in a fast stabilization of PSL. However, this could not be accomplished using intense UV excitation. Conclusions: Thermal treatment enables KCl:Eu{sup 2+} prototypes to be ready for readout in 1 h without the need of applying a large time-dependent correction factor. However, this cannot be achieved using optical preexcitation.

36 MATERIALS SCIENCE↗

TH-AB-BRA-09: Stability Analysis of a Novel Dose Calculation Algorithm for MRI Guided Radiotherapy

Purpose: To determine the iterative deterministic solution stability of the Linear Boltzmann Transport Equation (LBTE) in the presence of magnetic fields. Methods: The LBTE with magnetic fields under investigation is derived using a discrete ordinates approach. The stability analysis is performed using analytical and numerical methods. Analytically, the spectral Fourier analysis is used to obtain the convergence rate of the source iteration procedures based on finding the largest eigenvalue of the iterative operator. This eigenvalue is a function of relevant physical parameters, such as magnetic field strength and material properties, and provides essential information about the domain of applicability required for clinically optimal parameter selection and maximum speed of convergence. The analytical results are reinforced by numerical simulations performed using the same discrete ordinates method in angle, and a discontinuous finite element spatial approach. Results: The spectral radius for the source iteration technique of the time independent transport equation with isotropic and anisotropic scattering centers inside infinite 3D medium is equal to the ratio of differential and total cross sections. The result is confirmed numerically by solving LBTE and is in full agreement with previously published results. The addition of magnetic field reveals that the convergence becomes dependent on the strength of magnetic field, the energy group discretization, and the order of anisotropic expansion. Conclusion: The source iteration technique for solving the LBTE with magnetic fields with the discrete ordinates method leads to divergent solutions in the limiting cases of small energy discretizations and high magnetic field strengths. Future investigations into non-stationary Krylov subspace techniques as an iterative solver will be performed as this has been shown to produce greater stability than source iteration. Furthermore, a stability analysis of a discontinuous finite element space-angle approach (which has been shown to provide the greatest stability) will also be investigated. Dr. B Gino Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization)

60 APPLIED LIFE SCIENCES↗

Recent Progress to Understand and Improve Zeolite Stability in the Aqueous Medium

The work reviewed here attempts to summarize the growing literature on zeolite stability in hot liquid water. This required to first establish the nature, structure and interactions of the active sites in Brønsted and Lewis acidic microporous materials in the presence of liquid water. This understanding was then transferred to zeolite stability and catalyst deactivation. While early results correctly established Si–O–Si hydrolysis as the dominant pathway compared to the Si–O–Al hydrolysis observed in steaming, it also focused extensively on the positive role of framework and extra-framework Al in stabilizing zeolites. However, stability was instead found to more directly correlate with the number of internal structural defects and intraporous water concentration. Stabilization protocols for Brønsted acidic zeolites are described in detail. In the case of Lewis acidic zeolites, their inherent hydrophobic behavior (Si/M >100) makes them more resistant towards water, however, issues such as reversible carbonaceous species formation as well as irreversible metal leaching and fouling remain. Finally, we summarize the most important factors in designing robust and efficient zeolite catalysts made to withstand hot liquid water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MHD plasma stabilization in a chain of axisymmetric adiabatic open mirror cells

Conditions for convective plasma instability in a chain of axisymmetric adiabatic mirror cells with different signs of magnetic field curvature are analyzed. The boundaries of the region that can be occupied by a stable hollow plasma in a system of two connected cells-a nonparaxial simple mirror cell and a semicusp-are determined, as well as the interval of allowed values of the ratio between the pressures in the cells. Because of the large magnetic field curvature in the component cells, the safety factor that is achieved at both-external and internal-plasma boundaries in accordance with the average min-B principle can be high. It is assumed that the unperturbed pressure in each cell is almost isotropic, in which case the mirror ratio should necessarily be large. A key role in the stability of the plasma is played by its compressibility. A comparison is made between the conditions for complete plasma stabilization against arbitrary perturbations and the conditions for stability of individual cells against the global mode. The stability of the cells against the global mode is sufficient, but not necessary, for stabilizing the chain. The analysis is done by using orthogonal coordinates associated with the unperturbed magnetic field (flux variables). Numerical simulations were carried out for nonparaxial cells from a certain three-parameter family.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Convective plasma stability consistent with MHD equilibrium in magnetic confinement systems with a decreasing field

A study is made of the convective (interchange, or flute) plasma stability consistent with equilibrium in magnetic confinement systems with a magnetic field decreasing outward and large curvature of magnetic field lines. Algorithms are developed which calculate convective plasma stability from the Kruskal-Oberman kinetic criterion and in which the convective stability is iteratively consistent with MHD equilibrium for a given pressure and a given type of anisotropy in actual magnetic geometry. Vacuum and equilibrium convectively stable configurations in systems with a decreasing, highly curved magnetic field are calculated. It is shown that, in convectively stable equilibrium, the possibility of achieving high plasma pressures in the central region is restricted either by the expansion of the separatrix (when there are large regions of a weak magnetic field) or by the filamentation of the gradient plasma current (when there are small regions of a weak magnetic field, in which case the pressure drops mainly near the separatrix). It is found that, from the standpoint of equilibrium and of the onset of nonpotential ballooning modes, a kinetic description of convective stability yields better plasma confinement parameters in systems with a decreasing, highly curved magnetic field than a simpler MHD model and makes it possible to substantially improve the confinement parameters for a given type of anisotropy. For the Magnetor experimental compact device, the maximum central pressure consistent with equilibrium and stability is calculated to be as high as {beta} {approx} 30%. It is shown that, for the anisotropy of the distribution function that is typical of a background ECR plasma, the limiting pressure gradient is about two times steeper than that for an isotropic plasma. From a practical point of view, the possibility is demonstrated of achieving better confinement parameters of a hot collisionless plasma in systems with a decreasing, highly curved magnetic field than those obtained with the simplest MHD description.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessing Stability of Transition Metal Nitrides in Aqueous Environments: The Case of Molybdenum, Iron, Vanadium and Nickel Nitride

Analysis of the MoN, Mo 2 N, VN, Fe 2 N, Fe 4 N, Ni 3 N stability in the aqueous media was performed based on the thermodynamic data available in HSC Chemistry software. Our analysis show that among all the studied nitrides, cubic Mo 2 N is the most resistant while cubic VN is the least resistant to oxidation and decomposition. The change in temperature up to 100 °C does not significantly influence the formation potentials of transition metal oxides from nitrides; however, pH significantly affects the stability of the studied transition metal nitrides. In the case of Mo 2 N, MoN, and VN changing pH from acidic to neutral and alkaline decreases the stability of the nitrides and the oxide formation potentials shift to more negative values. Additionally, based on thermodynamics, orthorhombic Fe 2 N should be stable only in alkaline conditions, while cubic Fe 4 N and hexagonal Ni 3 N should be the most stable at pH ~ 7 and pH ~ 9. Changing pH from these values decreases the stability of both Fe 4 N and Ni 3 N and the formation of oxy-, hydroxy- species becomes thermodynamically more favorable. Overall, the limited stability of the metal nitrides places severe constraints for their use in aqueous electrocatalytic applications.

36 MATERIALS SCIENCE↗

Application of Benchmarked Kinetic Resistive Wall Mode Stability Codes to ITER, Including Additional Physics

Leading resistive wall mode (RWM) stability codes MARS-K [Y. Liu, et al., Phys. Plasmas 15, 112503 (2008)] and MISK [B. Hu, et al., Phys. Plasmas 12, 057301 (2005)] have been previously benchmarked. The benchmarking has now been extended to include additional physics, and used to project the stability of ITER in a realistic operating space. Due to ITER's relatively low plasma rotation and collisionality, collisions and non-resonance rotational effects were both found to have little impact on stability, and these non-resonance rotational effects also will not self-consistently affect the ITER RWM eigenfunction. Resonances between thermal ions and electrons and the expected level of ITER toroidal rotation were found to be important to stability, as were alpha particles, which are not in rotational resonance. MISK calculations show that without alpha particles, ITER is projected to be unstable to the RWM, but the expected level of alphas is calculated to provide a sufficient level of stability.

Resistive Wall Mode Stability↗

Experimental Images and Videos of Foam Stability (Half-life)

The experimental data obtained in this project is the thermal stability data of various foams measured using the setup established at Temple University during this study. The setup is installed with a portable digital camera which can take images and videos of foam evolution at a given pressure and temperature condition. Consequently, the half-life data was recorded from the images/videos, which are used as a measure of the thermal stability for foams. Over the 3 years of this project, four different surfactants and five different stabilizing agents were studied. The surfactants are, Alfa Olefin Sulfonate (AOS), Sodium Dodecyl Sulphate (SDS), Tergitol (NP-40), and Cetyltrimethylammonium chloride (CTAC). The stabilizing agents are, guar gum, bentonite clay, crosslinking agents, silicon dioxide nanoparticles (60 to 70nm), and graphene oxide dispersions. Foam stability was evaluated at different temperatures between 100C and 200cC, while the foam generation pressure varied between atmospheric pressure (14.7 psi) and 1000 psi. The images are saved as .jpg file and videos are saved as .avi files.

15 GEOTHERMAL ENERGY↗