Search NASA⌕ Search

SEARCH · Search NASA

Results for “Technology Performance Exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Cross-beam energy transfer saturation by ion trapping-induced detuning

The performance of direct-drive inertial confinement fusion implosions relies critically on the coupling of laser energy to the target plasma. Cross beam energy transfer (CBET), the resonant exchange of energy between intersecting laser beams mediated by ponderomotively driven ion-acoustic waves (IAW), inhibits this coupling by scattering light into unwanted directions. Furthermore, the variety of beam intersection angles and varying plasma conditions in an implosion results in IAWs with a range of phase velocities. Here we show that CBET saturates through a resonance detuning that depends on the IAW phase velocity and that results from trapping-induced modifications to the ion distribution functions. For smaller phase velocities, the modifications to the distribution functions can rapidly thermalize in the presence of mid-Z ions, leading to a blueshift in the resonant frequency. For larger phase velocities, the modifications can persist, leading to a redshift in the resonant frequency. Ultimately, these results may reveal pathways towards CBET mitigation and inform reduced models for radiation hydrodynamics codes to improve their predictive capability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comprehensive study of Al-induced layer-exchange growth for orientation-controlled Si crystals on SiO{sub 2} substrates

Orientation-controlled crystalline Si films on insulating substrates are strongly required to achieve high-performance thin-film devices for next-generation electronics. We have comprehensively investigated the layer-exchange kinetics of Al-induced crystallization (AIC) in stacked structures, i.e., amorphous-Si/Al-oxide/Al/SiO{sub 2}-substrates, as a function of the air-exposure time of Al surfaces (t{sub air}: 0–24 h) to form Al-oxide interface-layers, the thickness of Al and Si layers (d{sub Al,} d{sub Si}: 50–200 nm), the annealing temperature (450–500 °C), and the annealing time (0–50 h). It has been clarified that longer t{sub air} (>60 min) and/or thinner d{sub Al} and d{sub Si} (<50 nm) lead to the (111) oriented growth; in contrast, shorter t{sub air} (<60 min) and/or thicker d{sub Al} and d{sub Si} (>100 nm) lead to the (100) oriented growth. No correlation between the annealing temperature and the crystal orientation is observed. Detailed analysis reveals that the layer-exchange kinetics are dominated by “supply-limited” processing, i.e., diffusion of Si atoms into Al layers through Al-oxide layer. Based on the growth rate dependent Si concentration profiles in Al layers, and the free-energy of Si at Al-oxide/Al or Al/SiO{sub 2} interfaces, a comprehensive model for layer-exchange growth is proposed. This well explains the experimental results of not only Si-AIC but also another material system such as gold-induced crystallization of Ge. In this way, a growth technique achieving the orientation-controlled Si crystals on insulating substrates is established from both technological and scientific points of view.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical investigation and experimental validation of water condensation in the gas diffusion layer with different properties

Liquid water in porous media hinders the transport of reactant to catalyst layer, where the electrochemical reactions occur, which in turn, reduces performance and lifetime of a proton exchange membrane fuel cell (PEMFC). In this study, two types of gas diffusion layer (GDL) materials are used to study the two-phase saturation distribution in a PEMFC. The correlations between the effective and anisotropic transport properties and porosity of the two GDLs are solved by the pore scale model. In addition, the anisotropic liquid water permeability and the relationship between saturation pressure and capillary pressure is determined by using the Lattice-Boltzmann method. Fuel cell performance as well as liquid water distribution in the GDL using neutron radiography are obtained for validation. Under wet conditions, the cell with Freudenberg GDL performs better than that using Toray GDL, especially at high current densities. The results of the two-phase model simulation show that the peak water saturation for Toray GDL occurs in the catalyst layer and can reach 40%, while the peak water saturation for Freudenberg GDL occurs inside the GDL directly under the ribs and only reaches 25% saturation. The combined results provide key insights to enable high power density operation of a PEMFC through GDL material optimization.

42 ENGINEERING↗

In Situ XAFS, XRD, and DFT Characterization of the Sulfur Adsorption Sites on Cu and Ce Exchanged Y Zeolites

Adsorptive desulfurization with Cu and Ce ion-exchanged Y zeolite (CuCeY) has proven to be an effective method for the removal of sulfur compounds from hydrocarbon fuels. In this study, Cu and Ce exchanged Y materials including CuY, CeY, and CuCeY were prepared and examined to investigate the mechanism behind the superior sulfur adsorption and selectivity of CuCeY. In situ conditions were used to study the materials as prepared for optimal desulfurization. X-ray diffraction (XRD) confirmed the absence of large well-ordered crystalline phases from metallic or oxide Cu and Ce after the reduction of the samples. The oxidation states and local environments of Cu and Ce were determined using X-ray adsorption fine structure (XAFS) analysis and correlated to theoretical findings obtained from density functional theory (DFT) calculations. XAFS data indicate the successful reduction of Cu species to Cu + and Cu o , and Ce to Ce 3+ . Analysis of XAFS spectra located Cu and Ce within the Y zeolite framework with Cu cations in the six-member ring sites and as small metallic Cu clusters. Ce cations were found to occupy both six-member ring and hexagonal prism sites. Furthermore, these results reveal the structure of CuCeY as prepared for desulfurization and provide insight into its superior sulfur adsorption performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Future SDN-HPON Control Plane Architecture and Protocol for On-Demand Terabit End-to-End Extreme-Scale Science Applications

The UC Davis team conducted architecture, algorithm and experimental studies for next generation ultra-high-bandwidth optical networks in support of extreme-scale science applications. In particular, over the course of this 3-year project, the UC Davis team achieved the following main accomplishments: Designed a network architecture for automated multi-domain service provisioning: Designed information exchange schemes between autonomous systems (domains) Designed application programming interfaces to orchestrate resource reservation in data centers, high performance computation facilities, and communication networks belonging to different autonomous systems Experimentally assessed the multi-domain network architecture in a distributed field trial set-up connecting premises in three continents Designed a broker-based orchestrated multi-domain optical networking framework supporting observe-analyze-act cycle based cognitive inter-domain service provisioning: Designed an inter-domain operation mechanism, e.g., topology abstraction, for the broker plane and domain managers to collaboratively accomplish inter-domain service provisioning while respecting the autonomy of each administrative domain Designed an alien wavelength monitoring scheme and an artificial neural network based optical signal-to-noise ratio estimator for quality-of-transmission aware inter-domain service provisioning Developed a deep neural network based multi-domain traffic predictor and a cognitive routing and spectrum assignment algorithm to realize knowledge-based autonomous traffic engineering in multi-domain networks Implemented an optical signal-to-noise ratio estimator and traffic predictor with Google’s Tensor flow and assessed their performance using experimental and synthetic data Demonstrated the benefits of the proposed cognitive schemes with experiments ona two-domain elastic optical network testbed and evaluations on a six-domain simulation framework Built a two-domain software-defined networking control plane testbed using the ONOS platform and demonstrated the workflow of broker and domain manager cooperation, including hierarchical performance monitoring, topology abstraction and cognitive resource allocation. Designed self-learning cognitive service provisioning schemes using advanced machine learning technologies: Designed a self-taught anomaly detection framework for optical networks, including an unsupervised data clustering module for pattern recognition, a supervised data regression and classification module for online anomaly detection, and the system operation principle Experimentally validated the effectiveness of the self-taught anomaly detection framework with various failure/anomaly scenarios. Designed a self-learning autonomic routing, modulation and spectrum assignment (RMSA) provisioning framework for elastic optical networks with deep reinforcement learning. Designed effective modeling and training mechanisms for the self-learning RMSA framework Conducted extensive numerical simulations with various traffic patterns and topologies to verify the advantage of the self-learning RMSA framework.

42 ENGINEERING↗

A Novel Absorption Cycle for Combined Water Heating, Dehumidification, and Evaporative Cooling

In this study, development of a novel system for combined water heating, dehumidification, and space evaporative cooling is discussed. Ambient water vapor is used as a working fluid in an open system. First, water vapor is absorbed from an air stream into an absorbent solution. The latent heat of absorption is transferred into the process water that cools the absorber. The solution is then regenerated in the desorber, where it is heated by a heating fluid. The water vapor generated in the desorber is condensed and its heat of phase change is transferred to the process water in the condenser. The condensed water can then be used in an evaporative cooling process to cool the dehumidified air exiting the absorber, or it can be drained if primarily dehumidification is desired. Essentially, this open absorption cycle collects space heat and transfers it to process water. This technology is enabled by a membrane-based absorption/desorption process in which the absorbent is constrained by hydrophobic vapor-permeable membranes. Constraining the absorbent film has enabled fabrication of the absorber and desorber in a plate-and-frame configuration. An air stream can flow against the membrane at high speed without entraining the absorbent, which is a challenge in conventional dehumidifiers. Furthermore, the absorption and desorption rates of an absorbent constrained by a membrane are greatly enhanced. Isfahani and Moghaddam (Int. J. Heat Mass Transfer, 2013) demonstrated absorption rates of up to 0.008 kg/m2s in a membrane-based absorber and Isfahani et al. (Int. J. Multiphase Flow, 2013) have reported a desorption rate of 0.01 kg/m2s in a membrane-based desorber. The membrane-based architecture also enables economical small-scale systems, novel cycle configurations, and high efficiencies. The absorber, solution heat exchanger, and desorber are fabricated on a single metal sheet. In addition to the open arrangement and membrane-based architecture, another novel feature of the cycle is recovery of the solution heat energy exiting the desorber by process water (a process-solution heat exchanger ) rather than the absorber exiting solution (the conventional solution heat exchanger ). This approach has enabled heating the process water from an inlet temperature of 15 C to 57 C (conforming to the DOE water heater test standard) and interfacing the process water with absorbent on the opposite side of a single metal sheet encompassing the absorber, process-solution heat exchanger, and desorber. The system under development has a 3.2 kW water heating capacity and a target thermal coefficient of performance (COP) of 1.6.

Absorption Heat Pump↗

Calculating Hugoniots for molecular crystals from first principles.

Density Functional Theory (DFT) has over the last few years emerged as an indispensable tool for understanding the behavior of matter under extreme conditions. DFT based molecular dynamics simulations (MD) have for example confirmed experimental findings for shocked deuterium, enabled the first experimental evidence for a triple point in carbon above 850 GPa, and amended experimental data for constructing a global equation of state (EOS) for water, carrying implications for planetary physics. The ability to perform high-fidelity calculations is even more important for cases where experiments are impossible to perform, dangerous, and/or prohibitively expensive. For solid explosives, and other molecular crystals, similar success has been severely hampered by an inability of describing the materials at equilibrium. The binding mechanism of molecular crystals (van der Waals forces) is not well described within traditional DFT. Among widely used exchange-correlation functionals, neither LDA nor PBE balances the strong intra-molecular chemical bonding and the weak inter-molecular attraction, resulting in incorrect equilibrium density, negatively affecting the construction of EOS for undetonated high explosives. We are exploring a way of bypassing this problem by using the new Armiento-Mattsson 2005 (AM05) exchange-correlation functional. The AM05 functional is highly accurate for a wide range of solids, in particular in compression. In addition, AM05 does not include any van der Waals attraction, which can be advantageous compared to other functionals: Correcting for a fictitious van der Waals like attraction with unknown origin can be harder than correcting for a complete absence of all types of van der Waals attraction. We will show examples from other materials systems where van der Waals attraction plays a key role, where this scheme has worked well, and discuss preliminary results for molecular crystals and explosives.

36 MATERIALS SCIENCE↗

NASA Unmanned Aircraft (UA) Control and Non-Payload Communication (CNPC) System Waveform Trade Studies

Unmanned Aircraft Systems (UAS) represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the National Airspace System (NAS). To address this deficiency, NASA has established a project called UAS Integration in the NAS (UAS in the NAS), under the Integrated Systems Research Program (ISRP) of the Aeronautics Research Mission Directorate (ARMD). This project provides an opportunity to transition concepts, technology, algorithms, and knowledge to the Federal Aviation Administration (FAA) and other stakeholders to help them define the requirements, regulations, and issues for routine UAS access to the NAS. The safe, routine, and efficient integration of UAS into the NAS requires new radio frequency (RF) spectrum allocations and a new data communications system which is both secure and scalable with increasing UAS traffic without adversely impacting the Air Traffic Control (ATC) communication system. These data communications, referred to as Control and Non-Payload Communications (CNPC), whose purpose is to exchange information between the unmanned aircraft and the ground control station to ensure safe, reliable, and effective unmanned aircraft flight operation. A Communications Subproject within the UAS in the NAS Project has been established to address issues related to CNPC development, certification and fielding. The focus of the Communications Subproject is on validating and allocating new RF spectrum and data link communications to enable civil UAS integration into the NAS. The goal is to validate secure, robust data links within the allocated frequency spectrum for UAS. A vision, architectural concepts, and seed requirements for the future commercial UAS CNPC system have been developed by RTCA Special Committee 203 (SC-203) in the process of determining formal recommendations to the FAA in its role provided for under the Federal Advisory Committee Act. NASA intends to conduct its research and development in keeping with this vision and associated architectural concepts. The prototype communication systems developed and tested by NASA will be used to validate and update the initial SC-203 requirements in order to provide a foundation for SC-203's Minimum Aviation System Performance Standards (MASPS).

Aircraft Communications↗

Testing of Advanced Capabilities to Enable In-time Safety Management and Assurance for Future Flight Operations

In order to refine an initial Concept of Operations, explore Concepts of Use, and expose/validate requirements for future In-Time Aviation Safety Management Systems (IASMS), testing architectures were created, along with a set of capabilities and underlying information exchange protocols. These systems were conceived and developed based on hazards associated with two envisioned urban area flight domains: (1) highly autonomous small uncrewed aerial systems (sUAS) operating at low altitudes, and (2) highly autonomous air taxis. The initial scope of this development is described in [1]; this report provides an update, focusing on the subsequent developments and test activities. As stated in [1], it is important to note that there are many capabilities already in use by the industry (or soon to be in use) that will play critical roles in future IASMS designs. Those reported here were developed to address a gap in the current state-of-the-art regarding specific hazards/risks, and/or to allow for investigation of the interplay between and across hazard types — particularly regarding how overall safety risk can be reduced or managed effectively. Results of testing and development activities are organized by the operational phase wherein a particular capability would be employed (i.e., preflight, in-flight, and post-flight/off-line). Pre-flight: A set of capabilities were developed to help mitigate safety risk prior to flight (e.g., during flight and mission planning). Results of testing summarize (1) validation activities to raise the Technology Readiness Level (TRL) and (2) evaluation activities where the capabilities were applied to flight/mission planning procedures and used by operators/pilots. For the latter, flight plans were automatically assessed, and operators/pilots were notified of hazardous flight segments so as to enable adjustment of the flight plan and re-evaluation, and/or to better inform go/no-go decisions. Capabilities addressed hazards associated with power consumption, third-party risk, wind, navigation system performance, radiofrequency interference, and proximity to geo-spatial threats (e.g., buildings, trees, and no-fly zones). In-flight: Flight experiments tested capabilities that detect and respond to hazards encountered during flight. In the first series, safety hazards were monitored and assessed onboard, and system-generated mitigation maneuvers were recorded (but not acted upon by the vehicle). In the second series, mitigation maneuver commands directed the aircraft in response to safety hazards (i.e., auto-mitigation). The sUAS used for testing is described in full, as is the test architecture, which included commercial avionics, research avionics, and onboard software designed to detect, assess, and respond to hazards. The onboard system was designed as a run-time assurance framework, consistent with [2] and supportive of both supervisory and automated modes. The primary functions included: real-time risk assessment (RTRA), auto-pilot monitoring, constraint monitoring, and contingency select/triggering. RTRA performs integrated risk assessment considering data from several hazard-related monitors (e.g., battery, motors, navigation, communications, population density, and loss-of-control). Post-flight/off-line: Data monitored and recorded during flights can enable IASMS capabilities that execute after flights have completed (or “off-line”). These include: (1) the ability to identify anomalies and trends that may only be observable when comparing data spanning a number of similar flights; (2) the ability to update and validate pre-flight and in-flight capabilities and any underlying models to improve their performance; (3) the ability to report anomalies/off-nominals that may indicate design changes or maintenance actions are needed; and (4) the ability for humans involved in operations to report safety-relevant observations to help in understanding the flight data and/or the operational context of a flight. Progress on three such capabilities is summarized; the first investigates anomaly detection given a limited set of flight logs and applies an approach previously used for space operations. The second explores what could be identified using a larger set of flight logs, including from web-based forums where flight logs are posted by sUAS autopilot users. The third creates a new means of collecting information on UAS incidents and accidents via the Aviation Safety Reporting System (ASRS).

sUAS↗

Advanced blade-shaped thermal energy storage device: Development and application

Thermal energy storage (TES) using phase change materials (PCMs) is a promising approach for capturing and reusing excess thermal energy, yet widespread adoption is limited by low thermal conductivity, bulky configurations, and inadequate scalability. Here, this study presents a modular, blade-shaped TES prototype designed to address these challenges. The device integrates a lightweight aluminum shell, an embedded serpentine coil for active or passive heat exchange, and a cost-effective corrugated metal mesh for enhanced PCM thermal conductivity. With thickness-to-length and thickness-to-width ratios of 0.03 and 0.08, respectively, the blade-shaped TES achieves a compact, modular form factor suitable for space-constrained applications. Experimental testing demonstrated the efficient charge and discharge behavior of blade-shaped TES, capturing PCM superheating, phase-change transitions, and subcooling dynamics, with charging and discharging efficiencies of 94.9% and 94.6%, respectively. Also, the system can potentially achieve higher energy density than that of conventional TES designs. When integrated into a household refrigerator during the study, three blade-shaped TES modules successfully shifted 100% of peak-time compressor operation to off-peak hours, reducing energy consumption while maintaining more stable compartment temperatures. The blade-shaped TES's thin geometry, modularity, and enhanced thermal performance support scalable deployment across residential, commercial, and industrial applications, providing a versatile, cost-effective solution for high-efficiency, demand-flexible thermal energy management.

Blade-shaped↗

Cryogenic Carbon Capture Development (Final Report)

This project extends and leverages the work completed under funding from ARPA-E and other sources by exploring aspects of the Cryogenic Carbon Capture™ (CCC) process and issues discovered during those projects, but that were not within the scope or budget of previous projects or that became apparent during field tests. Our successful completion of the tasks outlined in this project has increased the reliability, efficiency, and scalability of the CCC process and we are better prepared for pilot-scale testing. The first phase of this project improved key areas of the process through iterative design and experiment, culminating with recommendations for improvements to the existing skid-scale system developed under non-federal funding. The second phase of this project implemented the improved unit operations into the Cryogenic Carbon Capture External Cooling Loop (CCC ECL™) skid and field tests the improved system at a coal-fired power plant. The specific areas of work in this project are: Budget Period 1: 1) Selection of the most energy-efficient drying system for ambient-pressure flue gas. Sustainable Energy Solutions, LLC (SES) has successfully demonstrated a dryer that removes bulk water using a low-temperature brine to remove about 99% of the water followed by a mol sieve 3A desiccant dryer to remove the remaining 1% water; 2) Selection and demonstration of efficient solution to fouling due to dissolved CO 2 . SES has tested several commercial heat exchangers that purport to be able to handle fouling issues similar to those experienced in the contact liquid chiller. Replicated tests using the CCC ECL™ skid and dimpled brazed plate heat exchangers demonstrate that quick throttling of refrigerant combined with a burst of clean gas mitigate the fouling caused by CO 2 solubility in contact liquid with only minor increases in parasitic load. SES models indicate that parasitic load would increase by approximately 0.0125 GJ/tonne, an order of magnitude less than what was determined to be the maximum allowable additional parasitic load caused by this system; 3) Selection and demonstration of efficient and scalable solid–liquid separation system. The screw press technology met or exceeded the 70% solids loading benchmark during several test runs exceeding 24 hours on the CCC ECL™ skid. The average solids loading during the entire 50-hour run was 67%. The energy demand for this system is less than 0.1 GJ e /tonne of CO 2 processed; 4) Optimize design and demonstration of patented desublimating heat exchangers. We designed and built a hybrid spray tower that was tested over many hundreds of hours and a 50-hour continuous test run was completed capturing over 0.5 tonne CO 2 /day at >90% capture; (5) Plan for safe dilution of oxygen-depleted, cleaned flue-gas stream. The AERSCREEN simulator developed by the EPA modeled the dispersion of oxygen-depleted flue gas from the CCC process at a commercial plant. The results indicate that this plan effectively mitigates the flue gas hazards; (6) Simulation of and experimental work related to multi-pollutant capture. SES programmed an upgrade to its solid/vapor/liquid equilibrium (SVLE) algorithm. This enables simultaneous modeling of multiple pollutants (i.e., CO 2 , SO x , NO x , Hg, HCl). Budget Period 2; (7) Modify the CCC ECL™ skid for field testing and complete shakedown testing. The plans for modifying the CCC ECL™ skid were finalized and put into place. Shakedown testing of the updated CCC ECL™ skid occurred at SES using closed-loop mode (i.e., using a synthetic flue gas consisting of only N 2 and CO 2 ) and at the Hunter Power Plant using flue gas from the coal-fired boiler. Shakedown testing took longer than expected due to delays in receiving equipment and unexpected equipment performance in the field; (8) Operate the CCC ECL™ skid in the field. Longer testing of the CCC ECL™ skid occurred at the Hunter Power Plant. Multiple tests exceeding 35 hours were completed, with a total of over 600 hours of CO 2 capture completed using flue gas at the Hunter Power Plant with an average CO 2 capture rate of over 91% during those hours. Extensive notes and documentation were acquired informing improved methods for controls, startup, operation, and shut down; (9) Determine figures of merit and quantify process improvement. SES defined figures of merit for unit operation performance and overall CCC ECL™ process performance. All figures of merit were achieved or surpassed, except for 500 continuous hours of demonstration at the Hunter Power Plant; (10) Complete an Environmental Health and Safety Risk assessment by a third party. Tri-State completed an Environmental Health and Safety Risk assessment; (11) Update techno-economic analysis with third-party validation. The techno-economic analysis has been completed. It confirms the potential large reduction in energy and cost of the CCC process compared with leading alternatives and that the estimates and estimation techniques are reliable.

20 FOSSIL-FUELED POWER PLANTS↗

Cation-Diffusive Carbon Interlayers Stabilize Na Metal and Double the Current in Na-S Redox-Flow Batteries for Grid-Scale Energy Storage

The sodium-sulfur nonaqueous redox-flow batteries (Na-S NARFBs) using earth-abundant elements are highly attractive due to the low material cost and improved energy density for grid-scale energy storage. However, the low current performance, poor Na0/Na+ redox kinetics, and Na dendrite growth pose severe challenges. We introduce cation-diffusive layers (CDLs): thin and Na+ affinitive interlayers at the Na anode that direct Na+ transport and stabilize Na deposition. Benchmarking three archetypal materials—carbon paper (CP), glass microfiber paper (GF), and foam—across Na-Na and Na-Cu, and Na-S cells identifies CP as the optimum. CP reduces symmetric cell overpotential by more than 70%, achieves 98% Na plating-stripping efficiency, and doubles the Na-S cell current density from 0.5 to 1.0 mA cm−2 without sacrificing capacity or efficiency. Ex situ electrochemical and SEM/XPS analysis, combined with molecular dynamics (MD) studies, reveal that electron-rich carbon fibers disperse supporting salt aggregates, enrich near-surface Na+ density, and create ion transport pathways for fast Na0/Na+ exchange while mitigating membrane degradation. Because of the ion-centric mechanism, CDLs can be generalized to other metal-anode designs. Further, this work establishes CDL design rules—cationic affinity and appropriate micro/nanostructure—as a simple, scalable route to high-current, durable metal-anode flow batteries.

Wu, Wenda [ORNL] (ORCID:000900033307687X)↗

Investigation of a transient energetic charge exchange flux enhancement (ʻspike-on-tailʼ) observed in neutral-beam-heated H-mode discharges in the National Spherical Torus Experiment

In the National Spherical Torus Experiment (NSTX), a large increase in the charge exchange neutral flux localized at the Neutral Beam (NB) injection full energy is measured by the E||B (superimposed parallel electric and magnetic fields) Neutral Particle Analyzer (NPA). Termed the High-Energy Feature (HEF), it appears on the NB-injected energetic ion spectrum only in discharges where tearing or kink-type modes (f < 50 kHz) are absent, Toroidal Alfvén Eigenmode (TAE) activity (f ~ 50 - 150 kHz) is weak and Global Alfvén Eigenmode (GAE) activity (f ~ 400 – 1000 kHz) is robust. Compressional Alfvén eigenmode (CAE) activity (f > 1000 kHz) is usually sporadic or absent during the HEF event. The HEF exhibits growth times of Δt ~ 20 - 80 ms, durations of ~ 100 – 600 ms and peak-to-base flux ratios up to H = F max /F min ~ 10. In infrequent cases, a slowing down distribution below the HEF energy can develop that continues to evolve over periods > 100 ms, a time scale long compared with the typical fast ion equilibration times. HEFs are Transient energetic charge exchange flux enhancement ('spike-on-tail') 2 observed only in H-mode (not L-mode) discharges with injected power P b ≥ 4 MW and in the pitch range χ = v ll /v ~ 0.7 – 0.9; i.e. only for passing particles. Increases of ~ 10 - 30 % in the measured neutron yield and total stored energy that are observed to coincide with the feature appear to be driven by concomitant broadening of measured Te(r), Ti(r) and ne(r) profiles and not the HEF itself. While the HEF has minimal impact on plasma performance, it nevertheless poses a challenging wave-particle interaction phenomenon to understand. Candidate mechanisms for HEF formation are developed based on quasilinear theory of wave-particle interaction. The only mechanism found to lead to the large NPA flux ratios, H = F max /F min , observed in NSTX is the quasilinear evolution of the energetic ion distribution, F b (E,χ,r), in phase space and the concomitant loss of some particles, which occurs due to the cyclotron interaction of the particles with destabilized modes having sufficiently high frequencies, f ~ 700 - 1000 kHz, in the plasma frame that are tentatively identified as Global Alfvén Eigenmodes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adsorption-Engineered Hydrocarbon Ionomers for Durable Proton-Exchange Membrane Fuel Cells

Reducing reliance on perfluoroalkyl substances (PFAS) in proton-exchange membrane fuel cells requires hydrocarbon ionomers that combine high performance with long-term durability, a persistent challenge in catalyst-layer design. Here, we identify oxidation-driven ionomer-catalyst interfacial degradation as a dominant failure pathway in hydrocarbon ionomer-bonded cathodes and introduce an adsorption-engineering strategy to overcome this limitation. The comparison of a commercial sulfonated poly(phenylene) (Pemion) with structurally engineered sulfonated poly(fluorene)s demonstrated that electrode durability is governed by the interplay between ionomer adsorption strength and resistance to oxidative degradation on carbon-supported Pt catalysts. A poly(fluorene) ionomer with mobile alkyl sulfonic acid groups forms resilient interfaces, delivering 1.28 A cm−2 at 0.65 V under fully humidified H2/air conditions (80°C and 150 kPaabs), comparable to Pemion. After 90,000 accelerated potential cycles, the poly(fluorene)-bonded cathode exhibits significantly improved durability, with only 29% performance loss compared to 58% for Pemion; further molecular refinement reduces the loss to 17%, approaching that of Nafion-bonded cathodes (14%). These findings establish adsorption-engineered ionomer design that decouples interfacial anchoring from oxidative degradation as a general strategy for achieving durable, high-performance PFAS-free PEM fuel cell electrodes.

08 HYDROGEN↗

Conceptual System Design of a Supercritical CO{sub 2} cooled Micro Modular Reactor - 18492

Small modular reactor (SMR) concepts proposed in the past have compact size and a longer life reactor core than the conventional nuclear power plants. However, previous concepts based on the water-cooled technologies with a steam Rankine cycle have shown that the complete modularization is still technically challenging. This study suggests an innovative concept of a reactor directly cooled by supercritical carbon dioxide (S-CO{sub 2}) with S-CO{sub 2} Brayton cycle as a power conversion system, namely KAIST MMR (Micro Modular Reactor). To enhance neutron economy and maximize the fuel volume fraction of the core, a uranium carbide fuel controlled by drum type control rods was used in the fast-spectrum MMR. The core has long life (20 years) without refueling or reshuffling as well as inherent safety features. The reactor can be used as a distributed power source, and replace outdated fossil fuel power plants for small cities. Moreover, we propose a S-CO{sub 2} Brayton cycle as a power conversion system to achieve small, high performance and lightweight module. Thanks to the compact core and power conversion system, the entire system can be contained in a single module. The target of the system is to achieve small and compact system that can be transported via ground transportation of a single module containing the core and the power conversion system altogether. In order to meet this target single module s total weight is minimized in the order of 150 tons. The external size of a module is less than 7 m in length and 4 m in diameter. It produces 12 MWe electricity from 36 MWt reactor core. The S-CO{sub 2} Brayton cycle was optimized, and the cycle components were designed while maximizing the performance and minimizing the weight. A passive decay heat removal system utilizing shell and tube heat exchangers was also developed, and examined its performance with transient analysis code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A cryogen-free low temperature scanning tunneling microscope capable of inelastic electron tunneling spectroscopy

The design and performance of a cryogen-free low temperature scanning tunneling microscope (STM) housed in ultrahigh vacuum (UHV) are reported. The cryogen-free design was done by directly integrating a Gifford-McMahon cycle cryocooler to a Besocke-type STM, and the vibration isolation was achieved by using a two-stage rubber bellow between the cryocooler and a UHV-STM interface with helium exchange gas cooling. A base temperature of 15 K at the STM was achieved, with a possibility to further decrease by using a cryocooler with higher cooling power and adding additional low temperature stage under the exchange gas interface. Atomically sharp STM images and high resolution dI/dV spectra on various samples were demonstrated. Furthermore, we reported the inelastic tunneling spectroscopy on a single carbon monoxide molecule adsorbed on Ag(110) surface with a cryogen-free STM for the first time. Being totally cryogen-free, the system not only saves the running cost significantly but also enables uninterrupted data acquisitions and variable temperature measurements with much ease. In addition, the system is capable of coupling light to the STM junction by a pair of lens inside the UHV chamber. We expect that these enhanced capabilities could further broaden our views to the atomic-scale world.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Composite Membranes for High Throughput Solid-Liquid Separations at the Savannah River Site

New Composite Membranes for High Throughput Solid-Liquid Separations at the Savannah River Site R. Bhave (Oak Ridge National Laboratory. Oak Ridge, TN) and M. R. Poirier* (Savannah River National Laboratory, Aiken SC) Solid-liquid separation is the limiting step for many waste treatment processes at the Savannah River Site. SRNL researchers have identified the rotary microfilter as a technology to improve the rate of solid-liquid separation processes. SRNL is currently developing the rotary microfilter for radioactive service and plans to deploy the technology as part of the small column ion exchange process. The rotary microfilter can utilize any filter media that is available as a flat sheet. The current baseline membrane is a 0.5 micron (nominal) porous metal filter (Pall PMM050). Previous testing with tubular filters showed that filters composed of a ceramic membrane on top of a stainless steel support produce higher flux than filters composed only of porous metal. The authors are working to develop flat sheet filter media composed of a ceramic membrane and/or ceramic-metal composite on top of a porous stainless steel support that can be used with the rotary microfilter to substantially increase filter flux resulting in a more compact, energy efficient and cost-effective high level radioactive waste treatment system. Composite membranes with precisely controlled pore size distribution were fabricated on porous metal supports. High quality uniform porous metal (316SS) supports were fabricated to achieve high water permeability. Separative layers of several different materials such as ultrafine metal particles and ceramic oxides were used to fabricate composite membranes. The fabrication process involved several high temperature heat treatments followed by characterization of gas and liquid permeability measurements and membrane integrity analysis. The fabricated composite membrane samples were evaluated in a static test cell manufactured by SpinTek. The composite membranes were evaluated on several feed slurries: 1 wt. % strontium carbonate in deionized water, 1 wt. % monosodium titanate in simulated salt solution, and 1 wt. % simulated sludge in simulated salt solution and deionized water. Flux as a function of feed flow rate and transmembrane pressure was measured for each of the above described feed slurries. The authors will discuss the new membrane development efforts, waste slurry filtration performance evaluations and scale-up considerations.

Bhave, Ramesh R↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

Cameron J. Hines↗