Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Tracing fetal and childhood exposure to lead using isotope analysis of deciduous teeth

We report progress in using the isotopic composition and concentration of Pb in the dentine and enamel of deciduous teeth to provide a high resolution time frame of exposure to Pb during fetal development and early childhood. Isotope measurements (total Pb and {sup 208}Pb/{sup 206}Pb, {sup 207}Pb/{sup 206}Pb ratios) were acquired by laser ablation inductively coupled mass spectrometry at contiguous 100 micron intervals across thin sections of the teeth; from the outer enamel surface to the pulp cavity. Teeth samples (n=10) were selected from two cohorts of children, aged 5–8 years, living in NE England. By integrating the isotope data with histological analysis of the teeth, using the daily incremental lines in dentine, we were able to assign true estimated ages to each ablation point (first 2–3 years for molars, first 1–2 years for incisors+pre-natal growth). Significant differences were observed in the isotope composition and concentration of Pb between children, reflecting differences in the timing and sources of exposure during early childhood. Those born in 2000, after the withdrawal of leaded petrol in 1999, have the lowest dentine Pb levels (<0.2 µg Pb/g) with {sup 208}Pb/{sup 206}Pb (mean ±2σ: 2.126–2.079) {sup 208}Pb/{sup 206}Pb (mean ±2σ: 0.879–0.856) ratios that correlate very closely with modern day Western European industrial aerosols (PM{sub 10}, PM{sub 2.5}) suggesting that diffuse airborne pollution was probably the primary source and exposure pathway. Legacy lead, if present, is insignificant. For those born in 1997, dentine lead levels are typically higher (>0.4 µgPb/g) with {sup 208}Pb/{sup 206}Pb (mean ±2σ: 2.145–2.117) {sup 208}Pb/{sup 206}Pb (mean ±2σ: 0.898–0.882) ratios that can be modelled as a binary mix between industrial aerosols and leaded petrol emissions. Short duration, high intensity exposure events (1–2 months) were readily identified, together with evidence that dentine provides a good proxy for childhood changes in the isotope composition of blood Pb. Our pilot study confirms that laser ablation Pb isotope analysis of deciduous teeth, when carried out in conjunction with histological analysis, permits a reconstruction of the timing, duration and source of exposure to Pb during early childhood. With further development, this approach has the potential to study larger cohorts and appraise environments where the levels of exposure to Pb are much higher. - Highlights: • Reconstructing a high resolution chronology of early childhood exposure to lead. • Combined laser ablation lead isotope – histological analysis of children's teeth. • Using dentine to recover information on the intensity, duration and source of lead. • Importance of industrial airborne lead pollution in a post-leaded petrol era.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Eastern North Atlantic Aerosol Mask (ENA-AM) with the Condensation Particle Counter (CPC) at Central Facility (C1) during Winter 2017

Eastern North Atlantic (ENA) Aerosol Mask (ENA-AM) is a mask developed to isolate high concentration aerosol events and identify the regional baseline in one minute time resolution CPC measurements collected at ENA central site during Winter 2017(December 1-30). ENA-AM is based on the statistically different behavior of adjacent data points during background and pollution peaks measurements. Measurements that differ by more than &alpha; times the standard deviation (&sigma;m) of the data below the median plus the two points after are masked by ENA-AM.

54 ENVIRONMENTAL SCIENCES↗

NPFTURBULENCE: Best Estimate Aerosol Size Distribution by airborne measurements

The original data were collected during the field campaign of “Turbulent layers promoting New Particle Formation” experiment (NPFTURBULENCE; https://www.arm.gov/research/campaigns/aaf2024npfturbulence) over the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) Atmospheric Observatory (https://www.arm.gov/capabilities/observatories/sgp ) in north-central Oklahoma. The ARM Aerial Facility ArcticShark uncrewed aerial system (UAS) was based at Blackwell–Tonkawa Municipal Airport (IATA: BWL, ICAO: KBKN, FAA LID: BKN, 36.74475° N, 97.34918° W, 313.9 m MSL), for the field campaign from May 5 through May 29, 2024. The ArcticShark UAS performed 11 flights, including 10 research flights over the Central Facility of the ARM SGP to measure atmospheric state, turbulence, surface IT temperature and imagery, aerosol number concentration and size distribution. The current data set presents Best Estimate Aerosol Size Distribution: a merged aerosol size distribution composed of the data from 2 sensors: miniaturized Scanning Electrical Mobility Sizer (mSEMS) and Portable Optical Particle Spectrometer (POPS). The mSEMS data were interpolated to 1 second from “native” time resolution of about 15 second to match the other probe. The POPS data were converted from equivalent optical size into geometric size using value of aerosol refractive index of 1.477 from the HISCALE field campaign (same geographical area, altitudes, and time of year; http://www.arm.gov/campaigns/aaf2016hiscale ).

54 ENVIRONMENTAL SCIENCES↗

MFRED, 10 second interval real and reactive power for groups of 390 US apartments of varying size and vintage

Abstract Building electricity is a major component of global energy use and its environmental impacts. Detailed data on residential electricity use have many interrelated research applications, from energy conservation to non-intrusive load monitoring, energy storage, integration of renewables, and electric vs. fossil-based heating. The dataset presented here, Multifamily Residential Electricity Dataset (MFRED), contains the electricity use of 390 apartments, ranging from studios to four-bedroom units. All apartments are located in the Northeastern United States (IECC-climate-zone 4 A), but differ in their heating/cooling system and construction year (early to late 20 th century). To adhere to privacy guidelines, data were averaged across 15 apartments each, based on annual electricity use. MFRED includes real and reactive power, at 10-second resolution, for January to December 2019 (246 million data points). The annual average real power per apartment is 343 W (3.27 W/m 2 of floor area), with strong variation between seasons and apartment size. Considering its large number of apartments, high time resolution, real and reactive power, and 12-month duration, MFRED is currently unique for the multifamily-sector.

97 MATHEMATICS AND COMPUTING↗

Time-resolved ion imaging at free-electron lasers using TimepixCam

In this paper, the application of a novel fast optical-imaging camera, TimepixCam, to molecular photoionization experiments using the velocity-map imaging technique at a free-electron laser is described. TimepixCam is a 256 × 256 pixel CMOS camera that is able to detect and time-stamp ion hits with 20 ns timing resolution, thus making it possible to record ion momentum images for all fragment ions simultaneously and avoiding the need to gate the detector on a single fragment. This allows the recording of significantly more data within a given amount of beam time and is particularly useful for pump–probe experiments, where drifts, for example, in the timing and pulse energy of the free-electron laser, severely limit the comparability of pump–probe scans for different fragments taken consecutively. Finally, in principle, this also allows ion–ion covariance or coincidence techniques to be applied to determine angular correlations between fragments.

47 OTHER INSTRUMENTATION↗

Discrete changes in solar coronal hole boundaries

Sequences of Skylab X-ray images near central meridian passages of a large solar coronal hole are used here to examine hole boundary changes with a time resolution of 90 min. It is found that X-ray bright points play a key role in both the expansion and contraction of the coronal hole. The size scale of the boundary changes is about 20,000 km, and the time scale is 3 hr or less. A scenario is suggested in which a large-scale closed magnetic field interacts with a bright point to effect a change in the hole boundary.

Kahler, S. W.↗

Scintillation light detection performance for the DUNE ND-LAr 2 × 2 modules

The Deep Underground Neutrino Experiment (DUNE) will be using a liquid argon time projection chamber (LAr TPC) with optically separated modules in the Near Detector (ND) complex. A prototype experiment, DUNE ND-LAr 2 × 2, is composed of four test modules. They detect ionization charge through a pixel-based readout and scintillation light through fibers in light collection modules and light traps called ArCLights. The light detection performance for two modules of DUNE ND-LAr 2 × 2 that took cosmic ray data at the University of Bern is shown. We present further the role of the 2 × 2 prototype in DUNE and how it is used to demonstrate the reconstruction capabilities of its light detectors in terms of energy thresholds and timing resolution.

47 OTHER INSTRUMENTATION↗

Advances in the Large Area Picosecond Photo-Detector (LAPPD TM ): 8" × 8" MCP-PMT with Capacitively Coupled Readout

Abstract We present advances made in the Large Area Picosecond Photodetector (LAPPD), an 8" × 8" microchannel plate photomultiplier tube (MCP-PMT), since pilot production was initiated at Incom, Inc. in 2018. The Gen-I LAPPD utilizes a stripline anode for direct charge readout. The novel Gen-II LAPPD employs an internal resistive thin-film which capacitively couples to a customizable external signal readout board, streamlining production and increasing customer flexibility. The Gen-II LAPPD, with an active area of 373 cm 2 , is capable of high single photoelectron (PE) gain of ∼10 7 , low dark rates (∼1 kHz/cm 2 ), single PE (SPE) timing resolution of ∼65 ps, and 𝒪(mm) position resolution. Coupled with a UV-grade fused silica window, the LAPPD features a high quantum efficiency (QE) bialkali photocathode of >30% at 365 nm with spectral response down to ∼165 nm. The LAPPD is an excellent candidate for electromagnetic calorimeter (ECAL) timing layers, photon-based neutrino detectors, high energy collider experiments, medical imaging systems, and nuclear non-proliferation applications.

Instruments & Instrumentation↗

Optically Induced Anisotropy in Time-Resolved Scattering: Imaging Molecular-Scale Structure and Dynamics in Disordered Media with Experiment and Theory

Time-resolved scattering experiments enable imaging of materials at the molecular scale with femtosecond time resolution. However, in disordered media they provide access to just one radial dimension thus limiting the study of orientational structure and dynamics. Here we introduce a rigorous and practical theoretical framework for predicting and interpreting experiments combining optically induced anisotropy and time-resolved scattering. Using impulsive nuclear Raman and ultrafast x-ray scattering experiments of chloroform and simulations, we demonstrate that this framework can accurately predict and elucidate both the spatial and temporal features of these experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Eastern North Atlantic Aerosol Mask (ENA-AM) with the Condensation Particle Counter (CPC) at Central Facility (C1) during Summer 2017

Eastern North Atlantic (ENA) Aerosol Mask (ENA-AM) is a mask developed to isolate high concentration aerosol events and identify the regional baseline in one minute time resolution CPC measurements collected at ENA central site during summer 2017(July 22 to August 20). ENA-AM is based on the statistically different behavior of adjacent data points during background and pollution peaks measurements. Measurements that differ by more than &alpha; times the standard deviation (&sigma;m) of the data below the median plus the two points after are masked by ENA-AM.

54 ENVIRONMENTAL SCIENCES↗

Unprecented syntonization and syncronization accuracy via simultaneous viewing with GPS receivers: Construction characteristics of an NBS/GPS receiver

The National Bureau of Standards/Global Positioning System (NBS/GPS) receiver is discussed. It is designed around the concept of obtaining high accuracy, low cost time and frequency comparisons between remote frequency standards and clocks with the intent to aid international time and frequency coordination. Preliminary tests of this comparison technique between Boulder, CO and Washington, D.C indicate the ability to do accurate time transfer to better that 10 ns, and frequency measurements to better than 1 part in 10 to the 14th power. The hardware and software of the receiver is detailed. The receiver is fully automatic with a built-in 0.1 ns resolution time interval counter. A microprocessor does data processing. Satellite signal stabilities are routinely at the 5 ns level for 15 s averages, and the internal receiver stabilities are at the 1 ns level.

Davis, D. D.↗

High-resolution sounding rocket observations of large-amplitude Alfven waves

Shear Alfven waves with amplitudes greater than 100 mV/m were observed on two recent sounding rocket flights. The largest waveforms are best described as a series of step functions, rather than as broadband noise or as single frequency waves. Complete two-dimensional E and B measurements at 4-ms time resolution were made, showing a downward propagation direction and implying insignificant reflection from the ionosphere at frequencies greater than 1 Hz. Intense, field-aligned, low-energy electron fluxes accompany the waves. Acceleration of these electrons by the Alfven waves is shown to be feasible. The waves in at least one case have a sufficently large ponderomotive potential to generate the observed density fluctuations of order one.

Boehm, M. H.↗

A Search for Meteor Shower Signatures in the LDEF IDE Data

For 346 days after the deployment of the LDEF satellite on April 7, 1984, the tape recorder belonging to the Interplanetary Dust Experiment (DE) stored information on over 15,000 impacts made by submicron and larger-size particles on its metal oxide silicon (MOS) detectors. These detectors were mounted on trays facing in six orthogonal directions - LDEF ram and trailing edge, the poles of the LDEF orbit (north and south), and radially inward (towards the Earth) and outward (towards space). The 13.1 second time resolution provided by the IDE electronics, combined with the high sensitivity of the MOS detectors and large collecting area (approximately 1 sq.m) of the experiment, conclusively showed that the small particle environment at the LDEF altitude of 480 km was highly time-variable, with particle fluxes spanning over four orders of magnitude. A large number of the 15,000 impacts recorded by IDE occurred in groups, which were of two types - the spikes, single, isolated events of high intensity and the multiple orbit event sequences (MOES), which were series of events separated in time by integer multiples of the LDEF orbital period. Even though the spikes were generally more intense, the MOES could be quite long-lived, some lasting for many days. A previous paper by Cooke et al. attributed the MOES to impacts by man-made debris particles in orbits intersecting that of LDEF. The 20 day longevity of one of these events - termed the May Swarm - led to the suggestion that the debris particles must be con- stantly replenished by their source, as the orbits of micron sized particles will rapidly decay under the influence of radiation pressure and other non-gravitational forces, entering Earth's atmosphere after only a few revolutions. However, the date of onset of the May Swarm (May 22) and the long duration of this event may indicate a possible correlation with the annual Arietid meteor shower, which peaks around June 8. As this seemed to hold the promise of a less artificial explanation than a satellite or rocket body continuously dribbling debris, it was decided to take a fresh look at parts of the IDE data set in an attempt to detect meteor showers within the impact record.

Cooke, William J.↗

Investigation of the Photoinduced axial ligation process in the excited state of nickel (II) phthalocyanine

Photoinduced axial ligation process in the excited state of nickel(II) octabutoxyphthalocyanine (NiPcOBu8) in pyridine solvent has been investigated by ultrafast optical transient absorption and X-ray transient absorption spectroscopies. Although Ni phthalocyanine complexes have been reported to have no tendency to form sixcoordinate structure, the (d(z2),d(x2-y2)) state of NiPcOBu8 generated by photoexcitation of Q-band was discovered to axially ligate with the pyridine molecule very rapidly, on a timescale of (similar to)100 ps. Although the presence of an excited unligated (d,d) state cannot be confirmed due to the time resolution limit of the synchrotron X-ray probe pulse with (similar to)80 ps FWHM, the biexponential kinetics of the ground state recovery detected by the is 1s -> 4pz feature suggests the decay of the unligated (d,d) species with an 82ps time constant, while that of the ligated NiPcOBu8 species is 3-5 ns. The photoinduced ligation dynamics of NiPcOBu8 is vastly different compared to that of Ni porphyrin complexes. This study provides a structural basis on the ligation chemistry in both the ground and excited states of nickel complexes based on their electronic and nuclear structures.

Excited state structural dynamics↗

Measuring time of flight of fusion products in an inertial electrostatic confinement fusion device for spatial profiling of fusion reactions

A new diagnostic has been developed that uses the time of flight (TOF) of the products from a nuclear fusion reaction to determine the location where the fusion reaction occurred. The TOF diagnostic uses charged particle detectors on opposing sides of the inertial electrostatic confinement (IEC) device that are coupled to high resolution timing electronics to measure the spatial profile of fusion reactions occurring between the two charged particle detectors. This diagnostic was constructed and tested by the University of Wisconsin-Madison Inertial Electrostatic Confinement Fusion Group in the IEC device, HOMER, which accelerates deuterium ions to fusion relevant energies in a high voltage ({approx}100 kV), spherically symmetric, electrostatic potential well [J. F. Santarius, G. L. Kulcinski, R. P. Ashley, D. R. Boris, B. B. Cipiti, S. K. Murali, G. R. Piefer, R. F. Radel, T. E. Radel, and A. L. Wehmeyer, Fusion Sci. Technol. 47, 1238 (2005)]. The TOF diagnostic detects the products of D(d,p)T reactions and determines where along a chord through the device the fusion event occurred. The diagnostic is also capable of using charged particle spectroscopy to determine the Doppler shift imparted to the fusion products by the center of mass energy of the fusion reactants. The TOF diagnostic is thus able to collect spatial profiles of the fusion reaction density along a chord through the device, coupled with the center of mass energy of the reactions occurring at each location. This provides levels of diagnostic detail never before achieved on an IEC device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ultrafast pixel array camera system and its applications in high energy density physics

Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.

47 OTHER INSTRUMENTATION↗

Dust counter and mass analyser (DUCMA) measurements of comet Halley's coma from Vega spacecraft

Measurements of dust particles in comet Halley's coma from Vega spacecraft made with instruments using a new principle of dust detection and having a high time resolution over a large range of dust fluxes and masses are reported. The dust coma, whether quiescent (as seen by Vega 2) or containing a major jet structure, (as seen by Vega 1) displays large, short-term variations throughout which are at times quasi-periodic. The integral mass spectra increase in intensity to the lowest masses measured, and the flux levels lie approximately in the ranges estimated previously from ground-based observations. The coma is highly dynamical on all spatial and temporal scales, suggesting a complex structure of localized regions of dust emission from the nucleus.

Simpson, J. A.↗

Timing system for firing widely spaced test nuclear detonations

The national weapons design laboratories (Los Alamos National Laboratory and Lawrence Livermore National Laboratory) test fire nuclear devices at the Nevada Test Site (NTS), which is spread over an area of over 1200 square miles (a bit larger than the state of Rhode island). On each test there are hundreds of high time resolution recordings made of nuclear output waveforms and other phenomena. In order to synchronize these recordings with each other, with the nuclear device, and with offsite recordings, there is a requirement that the permanent command center and the outlying temporary firing sites be time tied to each other and to UTC to permit firing the shot at a predetermined time with an accuracy of about a microsecond. The system is so designed that this can reduce to about 100 nanoseconds if it should prove necessary in the future.

Ralph E. Partridge↗