Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Simulations of Two-Bunch Plasma Wakefield Accelerator Experiments at FACET

Simulation results of possible upcoming Plasma Wakefield Accelerator (PWFA) experiments at FACET are presented. In a two-bunch scenario, the second (accelerated) electron bunch can have multi-GeV energy gain and a small energy spread after less than 1 meter of propagation in a Cs plasma column.

43 PARTICLE ACCELERATORS↗

Vortex Radiometry: Enabling Frequency Agile Communications

Exponential proliferation of UAVs and CubeSats puts NASA's high priority communication systems at risk. UAVs and CubeSats are easy to acquire, modify and build, making it extremely likely that some will be used in unauthorized ways. While these systems provide several benefits to society, their increased use also increases the probability of unintentional signal interference, and even deliberate jamming of NASA's communication systems.This paper presents an algorithm to determine 1) when an interference induced fade will occur, 2) how long the fade will persist for and 3) how intense the fade will be. The algorithm requires data collected from Vortex Radiometers (VRs), which probe the RF environment using annular antenna beam patterns. A set of numerical simulations show that a multi-beam VR system can instruct a cognitive antenna to switch between Ka- and X-Band communications, in order to avert interference from small diameter noise sources. Analysis of the simulation results indicate that practical VR systems will require several concentric annular beam patterns, in order to mitigate fades from noise sources of various sizes. The paper concludes by identifying technology challenges that need to be overcome to achieve these capabilities.

Orbital Angular Momentum↗

Inference of the optimal pretarget electron beam parameters in a Monte Carlo virtual linac model through simulated annealing

The purpose of this study was to develop an efficient method to determine the optimal intensity distribution of the pretarget electron beam in a Monte Carlo (MC) accelerator model able to most accurately reproduce a set of measured photon field profiles for a given accelerator geometry and nominal photon beam energy. The method has the ability to reduce the number of simulations required to commission a MC accelerator model and has achieved better agreement with measurement than other methods described in literature. The method begins from a cylindrically symmetric pretarget electron beam (radius of 0.5 cm) of uniform intensity. This beam is subdivided into annular regions of fluence for which each region is individually transported through the accelerator head and into a water phantom. A simulated annealing search is then performed to determine the optimal combination of weights of the annular fluences that provide a best match between the measured dose distributions and the weighted sum of annular dose distributions for particular pretarget electron energy. When restricted to Gaussian intensity distributions, the optimization determined an optimal FWHM=1.34 mm for 18.0 MeV electrons, with a RMSE=0.49% on 40x40 cm{sup 2} lateral profiles. When allowed to deviate from Gaussian intensities a further reduction in RMSE was achieved. For our Clinac 21 EX accelerator MC model (based on the 1996 Varian Oncology Systems, Monte Carlo Project package), the optimal unrestricted intensity distribution was found to be a Gaussian-like solution (18.0 MeV, FWHM=1.10 mm, 40x40 cm{sup 2} profile, and RMSE=0.15%) with the presence of an extra focal halo contribution on the order of 10% of the maximum Gaussian intensity. Using the optimally derived intensity, 10x10 and 4x4 cm{sup 2} profiles were found to be in agreement with measurement with a maximum RMSE=0.49%. The optimized Gaussian and unrestricted values of the electron beam FWHM were both within the range of those inferred by focal spot image measurements performed by Jaffray et al.[''X-ray sources of medical linear accelerators: Focal and extra-focal radiation,'' Med. Phys. 20, 1417-1427 (1993)]. The inference of an extra focal pretarget electron component may be an indicator of a deficiency in the MC model and needs further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radial quasiballistic transport in time-domain thermoreflectance studied using Monte Carlo simulations

Recently, a pump beam size dependence of thermal conductivity was observed in Si at cryogenic temperatures using time-domain thermal reflectance (TDTR). These observations were attributed to quasiballistic phonon transport, but the interpretation of the measurements has been semi-empirical. Here, we present a numerical study of the heat conduction that occurs in the full 3D geometry of a TDTR experiment, including an interface, using the Boltzmann transport equation. We identify the radial suppression function that describes the suppression in heat flux, compared to Fourier's law, that occurs due to quasiballistic transport and demonstrate good agreement with experimental data. We also discuss unresolved discrepancies that are important topics for future study.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulations and Observations of Heating of Auroral Ion Beams

In the auroral zone, quasi-static parallel electric fields produce beams of ionospheric ions (e.g., H(+), He(+) and 0(+)), which flow outward into the magnetosphere, providing a significant source of ions for the ring current and plasma sheet. Because the velocities to which these beams are accelerated is dependent on the mass of the ions, differential flows between the various ion species can develop which are unstable to an ion-ion streaming instability. Particle simulations and observations from DE 1 are used to investigate the heating of the ion beams produced by this instability. It is shown that there is net transfer of energy from the light ions to the heavy ions, with the heavy ions reaching maximum velocities near the beam velocity of the light ions. Bulk heating of the heavy ions occurs when their relative density is low while high-energy tails are produced when their relative density is high. The heating is primarily parallel to the magnetic field if the difference in the heavy and light ion beam velocities is subsonic while both perpendicular and parallel heating can occur if it is supersonic. In the latter case, very strong heating of an intermediate ion's species such as He(+) can also occur. Comparison with observations shows features consistent with heating via the ion-ion instability including perpendicular heating in the supersonic regime and parallel heating in the subsonic regime and a change in the heating between these regimes as the ratio of the H(+) beam speed to the local sound speed is observed to decrease. This heating is, however, not always observed in association with enhanced wave emissions. This lack of waves is attributed to reabsorption of the waves as the ions become heated.

Winglee, R. M.↗

SU-E-T-638: Proton Beam Delivery to a Moving Lung Tumor and Monte Carlo Simulation with TOPAS

Purpose: To estimate the dose delivered to a moving lung tumor by proton therapy beams of different modulation types, and compare with Monte Carlo predictions. Methods: A radiology support devices (RSD) phantom was irradiated with therapeutic proton radiation beams using two different types of modulation: uniform scanning (US) and double scattered (DS). The Eclipse© dose plan was designed to deliver 1.00Gy to the isocenter of a static ∼3×3×3cm (27cc) tumor in the phantom with 100% coverage. The peak to peak amplitude of tumor motion varied from 0.0 to 2.5cm. The radiation dose was measured with an ion-chamber (CC-13) located within the tumor. The time required to deliver the radiation dose varied from an average of 65s for the DS beams to an average of 95s for the US beams. Results: The amount of radiation dose varied from 100% (both US and DS) to the static tumor down to approximately 92% for the moving tumor. The ratio of US dose to DS dose ranged from approximately 1.01 for the static tumor, down to 0.99 for the 2.5cm moving tumor. A Monte Carlo simulation using TOPAS included a lung tumor with 4.0cm of peak to peak motion. In this simulation, the dose received by the tumor varied by ∼40% as the period of this motion varied from 1s to 4s. Conclusion: The radiation dose deposited to a moving tumor was less than for a static tumor, as expected. At large (2.5cm) amplitudes, the DS proton beams gave a dose closer to the desired dose than the US beams, but equal within experimental uncertainty. TOPAS Monte Carlo simulation can give insight into the moving tumor — dose relationship. This work was supported in part by the Philips corporation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Numerical investigation of short-pulse laser radiation propagation in a turbulent atmosphere

An algorithm is presented for the numerical simulation of short-pulse optical radiation propagation in a turbulent atmosphere on the basis of the solution to the parabolic wave equation for the complex spectral amplitude of the wave field by the split-step method. We present examples of the use of this algorithm for simulating the propagation of a pulsed coherent spatially limited beam and a plane wave. It is shown that in the regime of strong optical turbulence the relative variance of fluctuations of energy density of femtosecond radiation becomes much smaller than the relative variance of the intensity of cw radiation. (laser radiation scattering)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-340: Dosimetry of a Small Field Electron Beam for Innovative Radiotherapy of Small Surface Or Internal Tumors

Purpose: An innovative small high intensity electron beams with energies from 6 to 12 MeV is being developed at Argonne National Laboratory to deliver an absorbed dose via a catheter to small malignant and nonmalignant lesions. This study reports on the initial dosimetric characteristics of this electron beam. These include output calibration, percent depth dose, beam profiles and leakage through the catheter. Methods: To simulate the narrow electron beam, the Argonne Wakefield Accelerator is used to produce high energy electron beams. The electron beam from the accelerator is monitored by measuring the current through a transmission coil while the beam shape is observed with a fluorescent screen. The dosimetry properties of the electron beam transmitting through bone and tissue-like materials are measured with nanodot optically stimulated luminescent dosimeters and EDR radiographic film. The 6 MV photon beam from a Varian True beam linac is used to calibrate both the OSLDs and the film. Results: The beam characteristics of the 12 MeV beam were measured. The properties of the small diameter, 5 mm, beam differs from that of broad clinical electron beams from radiotherapy linacs. Due to the lack of scatter from the narrow beam, the maximum dose is at the surface and the depth of the 50% depth dose is 35 mm compared to 51 mm for a clinical 12 MeV. The widths of the 90% isodose measured at the surface and depths of 2, 6, 12, and 16 mm varied from 6.6 to 8.8 mm while the widths of the FWHM isodose varied from 7.8 to 25.5 mm. Conclusion: Initial beam measurements show favorable dosimetric properties for its use in treating either small surface or internal lesions, particularly to deliver radiation at the time of surgery to maximize the dose to the lesion and spare normal tissue.

60 APPLIED LIFE SCIENCES↗

Head-on beam-beam compensation in RHIC

Head-on beam-beam compensation with electron lenses had been proposed for the SSC, LHC, and the Tevatron [1,2]. Two electron lenses are installed in the Tevatron [2-4], where they are routinely used as gap cleaner and have been tested in many other configurations. In RHIC there are 2 head-on beam-beam interactions at IP6 and IP8, and 4 long-range beam-beam interactions with large separation (10 mm) at the other IPs. We consider the partial indirect compensation of the head-on beam-beam effect with one electron lens in each ring. Together with intensity and emittance upgrades [5,6] our goal is to approximately double the luminosity over what can be achieved without these upgrades. A RHIC electron lens consists of: a DC electron gun, an electron beam transport to the main solenoid, the superconducting main solenoid in which the interaction with the hadron beam occurs, an electron beam transport to the collector, and an electron collector. The 2 electron lenses are located in IR10 between the DX beam separation dipoles. The proton beams pass through the main solenoids of both electron lenses, and interact head-on with one of them. The following is a slightly modified version of Ref. [7]. The table shows the main parameters of the proton beam and the electron lenses. References [8-11] present simulations for and discuss beam dynamics problems.

43 PARTICLE ACCELERATORS↗

Measurement of the spectral signature of small carbon clusters at near and far infrared wavelengths

A significant percentage of the carbon inventory of the circumstellar and interstellar media may be in the form of large refractory molecules (or small grains) referred to as carbon clusters. At the small end, uneven numbers of carbon atoms seem to be preferred, whereas above 12 atoms, clusters containing an even number of carbon atoms appear to be preferred in laboratory chemistry. In the lab, the cluster C-60 appears to be a particularly stable form and has been nicknamed Bucky Balls because of its resemblance to a soccer ball and to geodesic domes designed by Buckminster Fuller. In order to investigate the prevalence of these clusters, and their relationship to the polycyclic aromatic hydrocarbons (PAHs) that have become the newest focus of IR astronomy, it is necessary to determine the spectroscopic characteristics of these clusters at near and far infrared wavelengths. Described here is the construction of a near to far IR laser magnetic resonance spectrometer that has been built at the University of California Berkeley in order to detect and characterize these spectra. The equipment produces carbon clusters by laser evaporation of a graphitic target. The clusters are then cooled in a supersonic expansion beam in order to simulate conditions in the interstellar medium (ISM). The expansion beam feeds into the spectrometer chamber and permits concentrations of clusters sufficiently high as to permit ultra-high resolution spectroscopy at near and far IR wavelengths. The first successful demonstration of this apparatus occurred last year when the laboratory studies permitted the observational detection of C-5 in the stellar outflow surrounding IRC+10216 in the near-IR. Current efforts focus on reducing the temperature of the supersonic expansion beam that transport the C clusters evaporated from a graphite target into the spectrometer down to temperatures as low as 1 K.

Tarter, J.↗

Implementation of longitudinal dynamics with barrier RF in BETACOOL and comparison to ESME

The barrier bucket RF system is successfully used on Recycler storage ring at Fermilab. The special program code ESME was used for numerical simulation of longitudinal phase space manipulations. This program helps optimizing the various regimes of operation in the Recycler and increasing the luminosity in the colliding experiments. Electron and stochastic cooling increases the phase space density in all degrees of freedom. In the case of a small phase space volume the intrabeam scattering introduces coupling between the transverse and longitudinal temperatures of the antiproton beam. For numerical simulations of the cooling processes at the Recycler, a new model of the barrier buckets was implemented in the BETACOOL code. The comparison between ESME and BETACOOL codes for a stationary and moving barrier buckets is presented. This article also includes an application of the barrier bucket numerical model for simulation of the luminosity distribution for RHIC colliding experiments. These simulations take into account the specific longitudinal distribution of the bunch and the vertex size of the detector.

43 PARTICLE ACCELERATORS↗

Comprehensive magnetohydrodynamic hybrid simulations of Alfvén eigenmode bursts and fast-ion losses in the Large Helical Device

Comprehensive magnetohydrodynamic (MHD) hybrid simulations with neutral beam injection and collisions were conducted to investigate the Alfvén eigenmode (AE) bursts and the fast-ion losses in the large helical device (LHD) for the realistic conditions close to the experiments. In this study, it is found in the simulation of the slowing-down time scale that the AE bursts take place repetitively accompanied by fast-ion redistribution and losses leading to lower saturation levels of stored fast-ion energy than those in a classical calculation where the MHD perturbations are neglected. The fast-ion loss rate caused by the AE burst has the quadratic dependence on AE amplitude, which was observed in the LHD experiment. The majority of the lost fast ions are counter-passing particles whose velocity and pitch-angle are close to those of the beam injection. The second component of the lost fast ions is transit particles whose velocity is close to thermal velocity. The loss of the counter-passing particles occurs mainly during the AE bursts, while the transit particles are lost both during the AE bursts and the quiescent periods with larger loss rate than that in the classical calculation. The initial location of the lost counter-injected particles spreads from the plasma edge to the plasma center, while only the particles initially located in the peripheral region are lost for the co-injected beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High energy solar beam testing in the JPL 25-ft space simulator

Modifications to the individual components in the solar simulation system to improve performance and reduce costs are described. The improvements include: an increase in lamp power from 20 KW to 30 KW; a family of solar beams from 8 to 18.5 feet in diameter at intensities related to beam size with a maximum intensity of 12 solar constants over a 9 ft. diameter; and up to 1.1 megawatts of simulated solar energy in the lamp array.

Harrell, J. W.↗

Investigation of Donor and Acceptor Ion Implantation in AlN

AlGaN alloys with high Al composition and AlN based electronic devices are attractive for high voltage, high temperature applications, including microwave power sources, power switches and communication systems. AlN is of particular interest because of its wide bandgap of ~6.1eV which is ideal for power electronic device applications in extreme environments which requires high dose ion implantation. One of the major challenges that need to be addressed to achieve full utilization of AlN for opto and microelectronic applications is the development of a doping strategy for both donors and acceptors. Ion implantation is a particularly attractive approach since it allows for selected-area doping of semiconductors due to its high spatial and dose control and its high throughput capability. Active layers in the semiconductor are created by implanting a dopant species followed by very high temperature annealing to reduce defects and thereby activate the dopants. Recovery of implant damage in AlN requires excessively high temperature. In this SBIR program we began the investigation by simulation of ion beam implantation profiles for Mg, Ge and Si in AlN over wide dose and energy ranges. Si and Ge are implanted to achieve the n-type doping, Mg is investigated as a p-type doping. The simulation of implantation profiles were performed in collaboration between NRL and Agnitron using a commercial software known as Stopping and Range of Ions in Matter (SRIM). The simulation results were then used as the basis for ion implantation of AlN samples. The implanted samples were annealed by an innovative technique under different conditions and evaluated along the way. Raman spectroscopy and XRD were used to determine the crystal quality of the implanted samples, demonstrating the effectiveness of annealing in removing implant induced damage. Additionally, SIMS was used to verify that a nearly uniform doping profile was achieved near the sample surface. The electrical characteristics of the implanted samples were evaluated by TLM and Hall techniques. Generally, the implanted samples before and after annealing were found to be very resistive. Further work is required before the superior properties of AlN can be fully utilized.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulated scatter performance of an inverse-geometry dedicated breast CT system

The purpose of this work was to quantify the effects of scatter for inverse-geometry dedicated breast CT compared to cone-beam breast CT through simulations. The inverse geometry was previously proposed as an alternative to cone-beam acquisition for volumetric CT. The inverse geometry consists of a large-area scanned-source opposite a detector array that is smaller in the transverse direction. While the gantry rotates, the x-ray beam is rapidly sequenced through an array of positions, acquiring a truncated projection image at each position. Inverse-geometry CT (IGCT) is expected to detect less scatter than cone-beam methods because only a fraction of the object is irradiated at any time and the fast detector isolates the measurements from sequential x-ray beams. An additional scatter benefit is the increased air gap due to the inverted geometry. In this study, we modeled inverse-geometry and cone-beam dedicated breast CT systems of equivalent resolution, field of view, and photon fluence. Monte Carlo simulations generated scatter and primary projections of three cylindrical phantoms of diameters 10, 14, and 18 cm composed of 50% adipose/50% glandular tissue. The scatter-to-primary ratio (SPR) was calculated for each breast diameter. Monte Carlo simulations were combined with analytical simulations to generate inverse-geometry and cone-beam images of breast phantoms embedded with tumors. Noise representing the photon fluence of a realistic breast CT scan was added to the simulated projections. Cone-beam data were reconstructed with and without an ideal scatter correction. The CNR between breast tumor and background was compared for the inverse and cone-beam geometries for the three phantom diameters. Results demonstrated an order of magnitude reduction in SPR for the IGCT system compared to the cone-beam system. For example, the peak IGCT SPRs were 0.05 and 0.09 for the 14 and 18 cm phantoms, respectively, compared to 0.42 and 1 for the cone-beam system. For both geometries, the effects of scatter on contrast-to-noise ratio (CNR) were small for the 10 cm diameter phantom. The inverse-geometry improved the CNR by factors of 1.16 for the 14 cm phantom and 1.48 for the 18 cm phantom compared to a cone-beam acquisition without scatter correction. When an ideal scatter correction was applied to the cone-beam acquisition, the IGCT CNR improvements were 1.03 and 1.25 for the 14 and 18 cm phantoms. Overall, the results suggest that the inverse geometry may be advantageous for dedicated breast CT, an application that requires high-contrast resolution, spatial resolution, and dose efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved single particle potential for transport model simulations of nuclear reactions induced by rare isotope beams

Taking into account more accurately the isospin dependence of nucleon-nucleon interactions in the in-medium many-body force term of the Gogny effective interaction, new expressions for the single-nucleon potential and the symmetry energy are derived. Effects of both the spin (isospin) and the density dependence of nuclear effective interactions on the symmetry potential and the symmetry energy are examined. It is shown that they both play a crucial role in determining the symmetry potential and the symmetry energy at suprasaturation densities. The improved single-nucleon potential will be useful for more accurate simulation of nuclear reactions induced by rare-isotope beams within transport models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-G-JeP3-06: Lower KV Image Dose Are Expected From a Limited-Angle Intra-Fractional Verification (LIVE) System for SBRT Treatments

Purpose: In order to track the tumor movement for patient positioning verification during arc treatment delivery or in between 3D/IMRT beams for stereotactic body radiation therapy (SBRT), the limited-angle kV projections acquisition simultaneously during arc treatment delivery or in-between static treatment beams as the gantry moves to the next beam angle was proposed. The purpose of this study is to estimate additional imaging dose resulting from multiple tomosynthesis acquisitions in-between static treatment beams and to compare with that of a conventional kV-CBCT acquisition. Methods: kV imaging system integrated into Varian TrueBeam accelerators was modeled using EGSnrc Monte Carlo user code, BEAMnrc and DOSXYZnrc code was used in dose calculations. The simulated realistic kV beams from the Varian TrueBeam OBI 1.5 system were used to calculate dose to patient based on CT images. Organ doses were analyzed using DVHs. The imaging dose to patient resulting from realistic multiple tomosynthesis acquisitions with each 25–30 degree kV source rotation between 6 treatment beam gantry angles was studied. Results: For a typical lung SBRT treatment delivery much lower (20–50%) kV imaging doses from the sum of realistic six tomosynthesis acquisitions with each 25–30 degree x-ray source rotation between six treatment beam gantry angles were observed compared to that from a single CBCT image acquisition. Conclusion: This work indicates that the kV imaging in this proposed Limited-angle Intra-fractional Verification (LIVE) System for SBRT Treatments has a negligible imaging dose increase. It is worth to note that the MV imaging dose caused by MV projection acquisition in-between static beams in LIVE can be minimized by restricting the imaging to the target region and reducing the number of projections acquired. For arc treatments, MV imaging acquisition in LIVE does not add additional imaging dose as the MV images are acquired from treatment beams directly during the treatment.

60 APPLIED LIFE SCIENCES↗

Theoretical and experimental study of the space-charge oscillations in the electron-optical system of a relativistic gyrotron

A theoretical and experimental study of the oscillations of a space-charge cloud in a magnetron-injection gun of a powerful relativistic gyrotron has been performed. The charge storage occurs via electron-beam magnetic compression of the reflection of a part of the electrons having the highest transverse velocities from a magnetic mirror. It has been established that at high values of the compression coefficient the beam loses its stability that finally leads to the appearance of the beam current modulation at the frequency of the longitudinal oscillations of an electron beam in an adiabatic trap. According to the numerical simulations, the energy spread in the formed beam under these conditions reaches 4.6%, which is higher by an order of magnitude than that due to the space-charge effect in the beam transported along the metal tube.

43 PARTICLE ACCELERATORS↗