Search NASA⌕ Search

SEARCH · Search NASA

Results for “circularity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Radiation forces and torque on a rigid elliptical cylinder in acoustical plane progressive and (quasi)standing waves with arbitrary incidence

This paper presents two key contributions; the first concerns the development of analytical expressions for the axial and transverse acoustic radiation forces exerted on a 2D rigid elliptical cylinder placed in the field of plane progressive, quasi-standing, or standing waves with arbitrary incidence. The second emphasis is on the acoustic radiation torque per length. The rigid elliptical cylinder case is important to be considered as a first-order approximation of the behavior of a cylindrical fluid column trapped in air because of the significant acoustic impedance mismatch at the particle boundary. Based on the rigorous partial-wave series expansion method in cylindrical coordinates, non-dimensional acoustic radiation force and torque functions are derived and defined in terms of the scattering coefficients of the elliptic cylinder. A coupled system of linear equations is obtained after applying the Neumann boundary condition for an immovable surface in a non-viscous fluid and solved numerically by matrix inversion after performing a single numerical integration procedure. Computational results for the non-dimensional force components and torque, showing the transition from the progressive to the (equi-amplitude) standing wave behavior, are performed with particular emphasis on the aspect ratio a/b, where a and b are the semi-axes of the ellipse, the dimensionless size parameter, as well as the angle of incidence ranging from end-on to broadside incidence. The results show that the elliptical geometry has a direct influence on the radiation force and torque, so that the standard theory for circular cylinders (at normal incidence) leads to significant miscalculations when the cylinder cross section becomes non-circular. Moreover, the elliptical cylinder experiences, in addition to the acoustic radiation force, a radiation torque that vanishes for the circular cylinder case. The application of the formalism presented here may be extended to other 2D surfaces of arbitrary shape, such as Chebyshev cylindrical particles with a small deformation, stadiums (with oval shape), or other non-circular geometries.

42 ENGINEERING↗

Photoinduced molecular chirality probed by ultrafast resonant X-ray spectroscopy

Recently developed circularly polarized X-ray light sources can probe the ultrafast chiral electronic and nuclear dynamics through spatially localized resonant core transitions. Here, we present simulations of time-resolved circular dichroism signals given by the difference of left and right circularly polarized X-ray probe transmission following an excitation by a circularly polarized optical pump with the variable time delay. Application is made to formamide which is achiral in the ground state and assumes two chiral geometries upon optical excitation to the first valence excited state. Probes resonant with various K-edges (C, N, and O) provide different local windows onto the parity breaking geometry change thus revealing the enantiomer asymmetry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical simulation of adiabatons in electromagnetically induced transparency under quasi-resonance conditions

The evolution of adiabatons in electromagnetically induced transparency in the Λ scheme of degenerate quantum transitions J = 0 → J = 1 → J = 2 with Doppler broadening of spectral lines has been numerically simulated taking into account the effect of resonance detunings. It is shown that, in the case of linearly polarised fields, an increase in the probe-field resonance detuning (under exact-resonance conditions for the control radiation) leads to a transformation of electromagnetically induced transparency into electromagnetically induced absorption at certain stages. When the control-field resonance detuning is varied, the transparency of the medium for the probe (exactly resonant) radiation monotonically decreases with increasing detuning because of the rising role of single-photon absorption. In the case of circularly polarised control radiation and linearly polarised input probe field, a probe pulse propagating in the medium splits into two pulses with oppositely directed circular polarisations. An increase in the probe pulse resonance detuning (under exact-resonance conditions for the control radiation) leads primarily to an increase in the absorption by the medium of the probe pulse, the direction of circular polarisation for which coincides with the circular-polarisation direction for the control radiation. (nonlinear optical phenomena)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CRITERIA FOR FLUX ROPE ERUPTION: NON-EQUILIBRIUM VERSUS TORUS INSTABILITY

The coronal magnetic configuration of an active region typically evolves quietly for a few days before becoming suddenly eruptive and launching a coronal mass ejection (CME). The precise origin of the eruption is still under debate. The loss of equilibrium, or an ideal magnetohydrodynamic (MHD) instability such as torus instability are among the several mechanisms that have proposed to be responsible for the sudden eruptions. Distinct approaches have also been formulated for limited cases having circular or translation symmetry. We revisit the previous theoretical approaches setting them in the same analytical framework. The coronal field results from the contribution of a non-neutralized current channel added to a background magnetic field, which in our model is the potential field generated by two photospheric flux concentrations. The evolution on short Alfvenic timescale is governed by ideal MHD. We first show analytically that the loss of equilibrium and the stability analysis are two different views of the same physical mechanism. Second, we identify that the same physics is involved in the instabilities of circular and straight current channels. Indeed, they are just two particular limiting cases of more general current paths. A global instability of the magnetic configuration is present when the current channel is located at a coronal height, h, large enough so that the decay index of the potential field, {partial_derivative}ln |B {sub p}|/{partial_derivative}ln h, is larger than a critical value. At the limit of very thin current channels, previous analysis has found critical decay indices of 1.5 and 1 for circular and straight current channels, respectively. However, with current channels being deformable and as thick as that expected in the corona, we show that this critical index has similar values for circular and straight current channels, and is typically in the range [1.1,1.3].

79 ASTRONOMY AND ASTROPHYSICS↗

DISCOVERY OF POLARIZED EMISSION FROM TWO SOFT X-RAY-EMITTING INTERMEDIATE POLARS: UU Col AND NY Lup

We aim to investigate the magnetic field strengths and cyclotron emission of the two soft X-ray-emitting intermediate polars (IPs) UU Col and NY Lup. We study the connection between polars and soft X-ray-emitting IPs by searching for evidence of circularly polarized light in these two systems, which may be examples of progenitors of polars. We carried out photopolarimetric observations of our targets using the Very Large Telescope (UT2) and FORS1 at Paranal. Imaging polarimetry with good signal-to-noise and relatively high time resolution is possible for these targets using such a large telescope. Detection of circular polarization, modulated according to a white dwarf (WD) spin period, is clear evidence of cyclotron emission processes near the WD surface. The color dependence of the polarization allows us to make estimates of the magnetic field strength. We found that both UU Col and NY Lup emit circularly polarized light in the B and I bands, modulated at the spin period of the WD in each case. We add further confirmation to the idea that soft X-ray-emitting IPs emit circularly polarized light and that cyclotron emission plays an important role in these systems. This also suggests that some soft X-ray-emitting IPs might be progenitors of polars.

79 ASTRONOMY AND ASTROPHYSICS↗

ON THE ANISOTROPY IN EXPANSION OF MAGNETIC FLUX TUBES IN THE SOLAR CORONA

Most one-dimensional hydrodynamic models of plasma confined to magnetic flux tubes assume circular tube cross sections. We use potential field models to show that flux tubes in circumstances relevant to the solar corona do not, in general, maintain the same cross-sectional shape through their length and therefore the assumption of a circular cross section is rarely true. We support our hypothesis with mathematical reasoning and numerical experiments. We demonstrate that lifting this assumption in favor of realistic, non-circular loops makes the apparent expansion of magnetic flux tubes consistent with that of observed coronal loops. We propose that in a bundle of ribbon-like loops, those that are viewed along the wide direction would stand out against those that are viewed across the wide direction due to the difference in their column depths. That result would impose a bias toward selecting loops that appear not to be expanding, seen projected in the plane of sky. An implication of this selection bias is that the preferentially selected non-circular loops would appear to have increased pressure scale heights even if they are resolved by current instruments.

79 ASTRONOMY AND ASTROPHYSICS↗

THE PHOTOECCENTRIC EFFECT AND PROTO-HOT JUPITERS. III. A PAUCITY OF PROTO-HOT JUPITERS ON SUPER-ECCENTRIC ORBITS

Gas giant planets orbiting within 0.1 AU of their host stars are unlikely to have formed in situ and are evidence for planetary migration. It is debated whether the typical hot Jupiter smoothly migrated inward from its formation location through the proto-planetary disk, or was perturbed by another body onto a highly eccentric orbit, which tidal dissipation subsequently shrank and circularized during close stellar passages. Socrates and collaborators predicted that the latter model should produce a population of super-eccentric proto-hot Jupiters readily observable by Kepler. We find a paucity of such planets in the Kepler sample, which is inconsistent with the theoretical prediction with 96.9% confidence. Observational effects are unlikely to explain this discrepancy. We find that the fraction of hot Jupiters with an orbital period P > 3 days produced by the star-planet Kozai mechanism does not exceed (at two-sigma) 44%. Our results may indicate that disk migration is the dominant channel for producing hot Jupiters with P > 3 days. Alternatively, the typical hot Jupiter may have been perturbed to a high eccentricity by interactions with a planetary rather than stellar companion, and began tidal circularization much interior to 1 AU after multiple scatterings. A final alternative is that early in the tidal circularization process at high eccentricities tidal circularization occurs much more rapidly than later in the process at low eccentricities, although this is contrary to current tidal theories.

79 ASTRONOMY AND ASTROPHYSICS↗

Determining the WIMP mass from a single direct detection experiment; a more detailed study

The energy spectrum of nuclear recoils in weakly interacting massive particle (WIMP) direct detection experiments depends on the underlying WIMP mass. We study how the accuracy with which the WIMP mass could be determined by a single direct detection experiment depends on the detector configuration and the WIMP properties. We investigate the effects of varying the underlying WIMP mass and cross-section, the detector target nucleus, exposure, energy threshold and maximum energy, the local circular speed and the background event rate and spectrum. The number of events observed is directly proportional to both the exposure and the cross-section; therefore these quantities have the greatest bearing on the accuracy of the WIMP mass determination. The relative capabilities of different detectors for determining the WIMP mass depend not only on the WIMP and target masses, but also on their energy thresholds. The WIMP and target mass dependence of the characteristic energy scale of the recoil spectrum suggests that heavy targets will be able to measure the mass of a heavy WIMP more accurately. We find, however, that the rapid decrease of the nuclear form factor with increasing momentum transfer which occurs for heavy nuclei means that this is in fact not the case. Uncertainty in the local circular speed and non-negligible background would both lead to systematic errors in the WIMP mass determination. For deviations of {+-} 20 km s{sup -1} in the underlying value of the circular speed the systematic error is of order 10%, increasing with increasing WIMP mass. This error can be reduced by also fitting for the circular speed. With a single detector it will be difficult to disentangle a WIMP signal (and the WIMP mass) from background if the background spectrum has a similar shape to the WIMP spectrum (i.e. exponential background, or flat background and a heavy WIMP)

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of VSR invariant Chern-Simons Lagrangian on photon polarization

We propose a generalization of the Chern-Simons (CS) Lagrangian which is invariant under the SIM(2) transformations but not under the full Lorentz group. The generalized lagrangian is also invariant under a SIM(2) gauge transformation. We study the effect of such a term on radiation propagating over cosmological distances. We find that the dominant effect of this term is to produce circular polarization as radiation propagates through space. We use the circular polarization data from distant radio sources in order to impose a limit on this term.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SIMULATIONS OF DISK GALAXIES WITH COSMIC RAY DRIVEN GALACTIC WINDS

We present results from high-resolution hydrodynamic simulations of isolated Small Magellanic Cloud (SMC)- and Milky-Way-sized galaxies that include a model for feedback from galactic cosmic rays (CRs). We find that CRs are naturally able to drive winds with mass loading factors of up to ∼10 in dwarf systems. The scaling of the mass loading factor with circular velocity between the two simulated systems is consistent with η∝v{sub circ}{sup 1-2} required to reproduce the faint end of the galaxy luminosity function. In addition, simulations with CR feedback reproduce both the normalization and the slope of the observed trend of wind velocity with galaxy circular velocity. We find that winds in simulations with CR feedback exhibit qualitatively different properties compared to supernova-driven winds, where most of acceleration happens violently in situ near star forming sites. The CR-driven winds are accelerated gently by the large-scale pressure gradient established by CRs diffusing from the star-forming galaxy disk out into the halo. The CR-driven winds also exhibit much cooler temperatures and, in the SMC-sized system, warm (T ∼ 10{sup 4} K) gas dominates the outflow. The prevalence of warm gas in such outflows may provide a clue as to the origin of ubiquitous warm gas in the gaseous halos of galaxies detected via absorption lines in quasar spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Perihelion precession for modified Newtonian gravity

We calculate the perihelion precession {delta} for nearly circular orbits in a central potential V(r). Differently from other approaches to this problem, we do not assume that the potential is close to the Newtonian one. The main idea in the deduction is to apply the underlying symmetries of the system to show that {delta} must be a function of r{center_dot}V{sup ''}(r)/V{sup '}(r) and to use the transformation behavior of {delta} in a rotating system of reference. This is equivalent to say that the effective potential can be written in a one-parameter set of possibilities as the sum of centrifugal potential and potential of the central force. We get the following universal formula valid for V{sup '}(r)>0 reading {delta}(r)=2{pi}{center_dot}[(1/{radical}(3+r{center_dot}V{sup ''}(r)/V{sup '}(r)))-1]. It has to be read as follows: a circular orbit at this value r exists and is stable if and only if this {delta} is well-defined as real; and if this is the case, then the angular difference from one perihelion to the next one for nearly circular orbits at this r is exactly 2{pi}+{delta}(r). Then we apply this result to examples of recent interest like modified Newtonian gravity and linearized fourth-order gravity. In the second part of the paper, we generalize this universal formula to static spherically symmetric space-times ds{sup 2}=-e{sup 2{lambda}}{sup (r)}dt{sup 2}+e{sup 2{mu}}{sup (r)}dr{sup 2}+r{sup 2}d{omega}{sup 2}; for orbits near r it reads {delta}=2{pi}{center_dot}[(e{sup {mu}}{sup (r)}/{radical}(3-2r{center_dot}{lambda}{sup '}(r)+r{center_dot}{lambda}{sup ''}(r)/{lambda}{sup '}(r)))-1] and can be applied to a large class of theories. For the Schwarzschild black hole with mass parameter m>0 it leads to {delta}=2{pi}{center_dot}[(1/{radical}(1-(6m/r)))-1], a surprisingly unknown formula. It represents a strict result and is applicable for all values r>6m and is in good agreement with the fact that stable circular orbits exist for r>6m only. For r>>m, one can develop in powers of m and get the well-known approximation {delta}{approx_equal}(6{pi}m/r)

79 ASTRONOMY AND ASTROPHYSICS↗

Relativistic Euler's three-body problem, optical geometry, and the golden ratio

A Weyl solution describing two Schwarzschild black holes is considered. We focus on the Z{sub 2} invariant solution, with Arnowitt-Deser-Misner mass M{sub ADM}=2M{sub K}, where M{sub K} is the Komar mass of each black hole. For this solution the set of fixed points of the discrete symmetry is a totally geodesic submanifold. The existence and radii of circular photon orbits in this submanifold are studied, as functions of the distance 2L between the two black holes. For L{yields}0 there are two such orbits, corresponding to r=3M{sub ADM} and r=2M{sub ADM} in Schwarzschild coordinates. As the distance increases, it is shown that the two photon orbits approach one another and merge when M{sub K}={phi}L, where {phi} is the golden ratio. Beyond this distance there exist no circular photon orbits. The two null orbits delimit a forbidden band for timelike circular orbits, which is interpreted in terms of optical geometry. For large L, timelike circular orbits are allowed everywhere, as in the analogous Newtonian problem. The analysis is generalized by considering a Z{sub 2} invariant Weyl solution with an array of N black holes and also by charging the black holes, which connects the Weyl solution to a Majumdar-Papapetrou spacetime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimum Multinozzle Configuration for Minimizing the Rayleigh Integral During High-Frequency Transverse Instabilities

This paper develops a formalism for optimizing nozzle location/configuration with respect to combustion stability of high-frequency transverse modes in a can combustor. The stability of these acoustically noncompact flames was assessed using the Rayleigh integral (RI). Several key control parameters influence RI—flame angle, swirling strength, nozzle location, as well as nozzle location with respect to the acoustic mode shape. In this study, we consider a N-around-1 configuration such as typically used in a multi-nozzle can system and study the overall stability of this system for different natural transverse modes. Typically, such nozzles are distributed in a uniformly circular manner for which we study the overall RI, and for cases where RI > 0, we optimize the nozzle distribution that can reduce and minimize RI. For a fixed geometry such as a circular configuration, the analysis shows how the flame's parameters must vary across the different nozzles, to result in a relatively stable system. Additionally, for a fixed set of flame parameters, the analysis also indicates the noncircular distribution of the N nozzles that minimizes RI. Overall, the analysis aims to provide insights on designing nozzle locations around the center nozzle for minimal amplification of a given transverse mode.

42 ENGINEERING↗

Integrated Sustainable Product Design With Warranty and End-of-Use Considerations

The concept of integrated sustainable product design has recently emerged, aiming to incorporate downstream life cycle performance into the initial product design to enhance sustainability. Various sustainable product design tools based on life cycle assessment or quality function deployment have been established while the impact of reliability on circular practices has received limited attention. Recognizing the critical role of product reliability in post-design performance, this paper develops a product design optimization model that considers the warranty performance and the effect of end-of-use options. The model takes into account the effect of uncertain operating conditions on product reliability. Two optimization goals including the minimization of expected unit life cycle cost and environmental impact are achieved by the model. To demonstrate the benefits of the integrated approach, the model is applied to an electric motor design problem. The results highlight that integrating end-of-use options in the early design phase leads to adjustments in component selection and reliability design. Moreover, the circular utilization of used products enables cost savings throughout the product’s life cycle and contributes to environmental impact reduction. Finally, the study analyzes the effects of operating conditions, warranty policies, and take-back prices for used products on design decisions, providing valuable insights for product designers.

Integrated design↗

The Effects of Channel Supplies on Overall Film-Cooling Effectiveness

Abstract Cooling components in the hot section of a gas turbine are essential to component durability. Common methods of cooling include rib turbulators in internal passages and film cooling on external surfaces. The holes that produce the film cooling are fed from the internal channels often containing ribs. Consequently, there is an interdependence of internal heat transfer and external film cooling. The purpose of this study was to obtain a better understanding of the interaction of ribs and film cooling. To quantify the cooling performance, the surface temperatures were measured, from which overall effectiveness was calculated. For the experiments, additively manufactured test coupons were made of Inconel 718 to match engine Biot numbers. These test coupons had internal feed channels with and without ribs and had both cylindrical holes and meter-diffuser-shaped holes with 15 deg lateral expansion angles and a 1 deg forward expansion angle. A single rectangular channel was one type of feed channel. The other type of feed channel was individual circular channels, with each circular channel supplying an individual film-cooling hole. The experimental results showed that the circular individual channels have 80% higher baseline overall effectiveness than the single rectangular channels without any film cooling. Ribbed turbulators without film cooling also increased the overall effectiveness by 21% for single rectangular channels and by 29% for the circular individual channels compared to the respective non-ribbed channels. While the film cooling increased the overall effectiveness of all geometries, the single rectangular channels had increased overall effectiveness levels by up to twice that of the no film-cooling case. On average, the single rectangular channels had an 80% improvement from film cooling, whereas the individual channel feeds, on average, had only a 50% improvement, given their high baseline effectiveness levels.

Engineering↗

Dedicated breast CT: radiation dose for circle-plus-line trajectory

Purpose: Dedicated breast CT prototypes used in clinical investigations utilize single circular source trajectory and cone-beam geometry with flat-panel detectors that do not satisfy data-sufficiency conditions and could lead to cone beam artifacts. Hence, this work investigated the glandular dose characteristics of a circle-plus-line trajectory that fulfills data-sufficiency conditions for image reconstruction in dedicated breast CT. Methods: Monte Carlo-based computer simulations were performed using the GEANT4 toolkit and was validated with previously reported normalized glandular dose coefficients for one prototype breast CT system. Upon validation, Monte Carlo simulations were performed to determine the normalized glandular dose coefficients as a function of x-ray source position along the line scan. The source-to-axis of rotation distance and the source-to-detector distance were maintained constant at 65 and 100 cm, respectively, in all simulations. The ratio of the normalized glandular dose coefficient at each source position along the line scan to that for the circular scan, defined as relative normalized glandular dose coefficient (RD{sub g}N), was studied by varying the diameter of the breast at the chest wall, chest-wall to nipple distance, skin thickness, x-ray beam energy, and glandular fraction of the breast. Results: The RD{sub g}N metric when stated as a function of source position along the line scan, relative to the maximum length of line scan needed for data sufficiency, was found to be minimally dependent on breast diameter, chest-wall to nipple distance, skin thickness, glandular fraction, and x-ray photon energy. This observation facilitates easy estimation of the average glandular dose of the line scan. Polynomial fit equations for computing the RD{sub g}N and hence the average glandular dose are provided. Conclusions: For a breast CT system that acquires 300-500 projections over 2{pi} for the circular scan, the addition of a line trajectory with equal source spacing and constant x-ray beam quality (kVp and HVL) and mAs matched to the circular scan, will result in less than 0.18% increase in average glandular dose to the breast per projection along the line scan.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of ray profile modeling on resolution recovery in clinical CT

Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. However, among vendors and researchers, there is no consensus of how to best achieve these goals. The authors are focusing on the aspect of geometric ray profile modeling, which is realized by some algorithms, while others model the ray as a straight line. The authors incorporate ray-modeling (RM) in nonregularized iterative reconstruction. That means, instead of using one simple single needle beam to represent the x-ray, the authors evaluate the double integral of attenuation path length over the finite source distribution and the finite detector element size in the numerical forward projection. Our investigations aim at analyzing the resolution recovery (RR) effects of RM. Resolution recovery means that frequencies can be recovered beyond the resolution limit of the imaging system. In order to evaluate, whether clinical CT images can benefit from modeling the geometrical properties of each x-ray, the authors performed a 2D simulation study of a clinical CT fan-beam geometry that includes the precise modeling of these geometrical properties. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and a Forbild thorax phantom with circular resolution patterns representing calcifications in the heart region are simulated. An FBP reconstruction with a Ram–Lak kernel is used as a reference reconstruction. The FBP is compared to iterative reconstruction techniques with and without RM: An ordered subsets convex (OSC) algorithm without any RM (OSC), an OSC where the forward projection is modeled concerning the finite focal spot and detector size (OSC-RM) and an OSC with RM and with a matched forward and backprojection pair (OSC-T-RM, T for transpose). In all cases, noise was matched to be able to focus on comparing spatial resolution. The authors use two different simulation settings. Both are based on the geometry of a typical clinical CT system (0.7 mm detector element size at isocenter, 1024 projections per rotation). Setting one has an exaggerated source width of 5.0 mm. Setting two has a realistically small source width of 0.5 mm. The authors also investigate the transition from setting one to two. To quantify image quality, the authors analyze line profiles through the resolution patterns to define a contrast factor (CF) for contrast-resolution plots, and the authors compare the normalized cross-correlation (NCC) with respect to the ground truth of the circular resolution patterns. To independently analyze whether RM is of advantage, the authors implemented several iterative reconstruction algorithms: The statistical iterative reconstruction algorithm OSC, the ordered subsets simultaneous algebraic reconstruction technique (OSSART) and another statistical iterative reconstruction algorithm, denoted with ordered subsets maximum likelihood (OSML) algorithm. All algorithms were implemented both without RM (denoted as OSC, OSSART, and OSML) and with RM (denoted as OSC-RM, OSSART-RM, and OSML-RM). Results: For the unrealistic case of a 5.0 mm focal spot the CF can be improved by a factor of two due to RM: the 4.2 LP/cm bar pattern, which is the first bar pattern that cannot be resolved without RM, can be easily resolved with RM. For the realistic case of a 0.5 mm focus, all results show approximately the same CF. The NCC shows no significant dependency on RM when the source width is smaller than 2.0 mm (as in clinical CT). From 2.0 mm to 5.0 mm focal spot size increasing improvements can be observed with RM. Conclusions: Geometric RM in iterative reconstruction helps improving spatial resolution, if the ray cross-section is significantly larger than the ray sampling distance. In clinical CT, however, the ray is not much thicker than the distance between neighboring ray centers, as the focal spot size is small and detector crosstalk is negligible, due to reflective coatings between detector elements. Therefore,RM appears not to be necessary in clinical CT to achieve resolution recovery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-EF-207-01: FEATURED PRESENTATION and BEST IN PHYSICS (IMAGING): Task-Driven Imaging for Cone-Beam CT in Interventional Guidance

Purpose: This work introduces a task-driven imaging framework that utilizes a patient-specific anatomical model, mathematical definition of the imaging task, and a model of the imaging system to prospectively design acquisition and reconstruction techniques that maximize task-based imaging performance. Utility of the framework is demonstrated in the joint optimization of tube current modulation and view-dependent reconstruction kernel in filtered-backprojection reconstruction and non-circular orbit design in model-based reconstruction. Methods: The system model is based on a cascaded systems analysis of cone-beam CT capable of predicting the spatially varying noise and resolution characteristics as a function of the anatomical model and a wide range of imaging parameters. Detectability index for a non-prewhitening observer model is used as the objective function in a task-driven optimization. The combination of tube current and reconstruction kernel modulation profiles were identified through an alternating optimization algorithm where tube current was updated analytically followed by a gradient-based optimization of reconstruction kernel. The non-circular orbit is first parameterized as a linear combination of bases functions and the coefficients were then optimized using an evolutionary algorithm. The task-driven strategy was compared with conventional acquisitions without modulation, using automatic exposure control, and in a circular orbit. Results: The task-driven strategy outperformed conventional techniques in all tasks investigated, improving the detectability of a spherical lesion detection task by an average of 50% in the interior of a pelvis phantom. The non-circular orbit design successfully mitigated photon starvation effects arising from a dense embolization coil in a head phantom, improving the conspicuity of an intracranial hemorrhage proximal to the coil. Conclusion: The task-driven imaging framework leverages a knowledge of the imaging task within a patient-specific anatomical model to optimize image acquisition and reconstruction techniques, thereby improving imaging performance beyond that achievable with conventional approaches. 2R01-CA-112163; R01-EB-017226; U01-EB-018758; Siemens Healthcare (Forcheim, Germany)

60 APPLIED LIFE SCIENCES↗