Search NASA⌕ Search

SEARCH · Search NASA

Results for “code verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Tools and Tool Support for the Exascale Era

The goal of this paper is to highlight the challenges in providing scalable tool support on exascale class machines and to identify key research and development needs as well as opportunities to meet these challenges. In this context we define tool support very broadly as software that helps programmers to understand, optimize and fix their codes as well as software that facilitates interaction between application, run-time, and hardware. This includes tools for performance analysis, static and run-time optimization, debugging, correctness verification and program transformation. This paper is intended as background material for the ASC exascale workshop, held in March 2011 in San Francisco, to stimulate discussion both within the tools area and across working groups. Further, this paper targets both the issues and requirements users have on tools in the exascale era as well as the requirements that need to be fulfilled by exascale systems to build scalable tools.

97 MATHEMATICS AND COMPUTING↗

User Manual for MC 2 -3 Gamma Library Generation

This report provides the documentation for the revised procedure to generate the MC 2 -3 gamma library with the latest versions of PreGAMMA and GenGAMMA which have recently been updated to fix the program errors and inconsistent data processing for some isotopes identified in a recent verification and validation study of the MC 2 -3 gamma library. A few associated errors associated with gamma processing were also identified and fixed in the MC 2 -3 code. Addressing the changes in MC 2 -3, the procedure to generate the PMATRX and GAMISO datasets is discussed as well. The input data of PreGAMMA and GenGAMMA are discussed in detail using sample input data. In addition, the structure and formats of the MC 2 -3 gamma library are provided in detail.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Overview of the Tolerance Limit Calculations with Application to TSURFER

To establish confidence in the results of computerized physics models, a key regulatory requirement is to develop a scientifically defendable process. The methods employed for confidence, characterization, and consolidation, or C3, are statistically involved and are often accessible only to avid statisticians. This manuscript serves as a pedagogical presentation of the C3 process to all stakeholders—including researchers, industrial practitioners, and regulators—to impart an intuitive understanding of the key concepts and mathematical methods entailed by C3. The primary focus is on calculation of tolerance limits, which is the overall goal of the C3 process. Tolerance limits encode the confidence in the calculation results as communicated to the regulator. Understanding the C3 process is especially critical today, as the nuclear industry is considering more innovative ways to assess new technologies, including new reactor and fuel concepts, via an integrated approach that optimally combines modeling and simulation and minimal targeted validation experiments. This manuscript employs intuitive, analytical, numerical, and visual representations to explain how tolerance limits may be calculated for a wide range of configurations, and it also describes how their values may be interpreted. Various verification tests have been developed to test the calculated tolerance limits and to help delineate their values. The manuscript demonstrates the calculation of tolerance limits for TSURFER, a computer code developed by the Oak Ridge National Laboratory for criticality safety applications. The goal is to evaluate the tolerance limit for TSURFER-determined criticality biases to support the determination of upper, subcritical limits for regulatory purposes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Eucalyptus – An Analysis Suite for Fault Trees with Uncertainty Quantification

Eucalyptus is a novel code developed at Lawrence Livermore National Laboratory to incorporate uncertainty quantification into Fault Tree Analysis (FTA). This tool addresses the challenge of imperfect knowledge in “grey-box” systems by allowing analysts to incorporate and propagate uncertainty from component-level assessments to system-level effects. Eucalyptus facilitates a consistent evaluation of the impact of subject matter expert judgment and knowledge gaps on overall system response by Monte Carlo generation of possible system fault trees, sampling probabilities of the existence of subsystems and components. Here, the code supports the specification of fault trees through text and allows export to various formats, including auto-generated images, easing analysis and reducing errors. It has undergone extensive verification testing, demonstrating its reliability and readiness for deployment, and leverages on-node parallelism for rapid analysis. Example analyses are shown that include the identification of system failure paths and quantification of the value of further information about system components.

Fault Tree Analysis↗

NREL Hydrogen Sensor Testing Laboratory

The NREL Sensor Laboratory supports the HFTO's mission for the safe and efficient implementation of hydrogen as an energy carrier. Sensors are a critical element for a facility safety system by providing an early indication of unintended releases. Sensors can be used in process control applications (e.g., FQ verification). The Sensor Laboratory provides developers and end-users with an unbiased resource to validate sensor performance to application requirements. The Sensor Laboratory facilitates deployment through support of codes and standards development and safety research. The Sensor Laboratory supports advanced strategies for early leak detection.

detection↗

Calculating infinite-medium {alpha}-eigenvalue spectra with a transition rate matrix method

The time-dependent behavior of the energy spectrum in neutron transport was investigated with a formulation, based on continuous-time Markov processes, for computing {alpha}-eigenvalues and eigenvectors in an infinite medium. For this, a research Monte Carlo code called TORTE was created and used to estimate elements of a transition rate matrix. TORTE is capable of using both multigroup and continuous-energy nuclear data, and verification was performed. Eigenvalue spectra for infinite homogeneous mixtures were obtained and an eigenfunction expansion was used to investigate transient behavior of the neutron energy spectrum. (authors)

97 MATHEMATICS AND COMPUTING↗

Development of MELCOR 2.1 Guidance Report for LPF Applications

A complex nuclear facility includes several pathways that can transport accidentally released materials throughout the facility and potentially to the exterior environment. To model and estimate material transport and possible release as a source term from a U.S. Department of Energy (DOE) nuclear facility requires proficiency in applying simulation tools, such as the MELCOR code. DOE has designated MELCOR version 1.8.5, an obsolete version, as a DOE Tool Box code in its Central Registry. A leak path factor (LPF) guidance report written in 2004 did not include experimental validation data. Using an obsolete version of MELCOR requires additional verification and validations, which may be cost prohibitive. Without any developer support and lack of experimental data validation, it is difficult to justify to regulators that the calculated source term with the obsolete version of MELCOR from the facility is accurate and defensible. The goal of this work is to replace the obsolete guidance report with MELCOR 2.1 with experimental validations. In this paper, we will present our approach to develop a MELCOR 2.1 guidance report for LPF applications. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analog neutron transport for nuclear instrumentation applications with the Monte-Carlo code TRIPOLI-4 - Paper 3

Monte-Carlo codes simulating particle transport usually make use of well-known variance reduction techniques, leading to more efficient simulations. Even in configurations which do not deal with deep-penetration, some of these techniques, such as the implicit capture, are actually often used by default. The statistical weight of the simulated particles is then modified in order to take into account the modification of the sampling without introducing any bias in the estimation process. For instance, the implicit capture decreases the statistical weight of the particles at each collision, whereas the sampling of a single outgoing particle increases this statistical weight in case of scattering reactions producing multiple neutrons. In addition, Russian roulette and splitting operations, which are usually also played at each collision, lead to other modifications of the statistical weights. As a result, Monte-Carlo codes provide particle histories that are valid on average, but collect statistical weights which differ from 1, when tallying the estimation of the quantities of interest. Yet, some nuclear instrumentation calculations inherently need to work with statistical weights equal to 1, since either individual events have to be collected (such as the arrival of a particle at a detector, the measurement of a time of flight, etc), or the coincidence of events or also correlations between individual events have to be taken into account. To address these specific applications with Monte-Carlo simulation codes, users need a full analog simulation mode. The continuous-energy Monte-Carlo code TRIPOLI4{sup R} is mainly dedicated to shielding, reactor physics and criticality safety calculations. Its capabilities have recently been extended to widen its use to nuclear instrumentation with the possibility of γ-spectrometry calculations and the simulation of photonuclear reactions for instance. Other features needed by nuclear instrumentation applications have been available in TRIPOLI-4 for a long time, such as the sampling of the time variable and the possibility of tallying in a time grid for most of the available tallies (fluxes, reaction rates, dose equivalent rates, energy depositions, etc). In TRIPOLI-4, the transport between two consecutive collisions is analog if no variance reduction technique is requested by the user to handle deep-penetration configurations. However, up to the version 9 of the code, the collision itself is sampled in a non-analog way. This paper presents a first implementation of a full analog neutron transport mode in TRIPOLI-4, preliminary verification results and an application of this functionality to the simulation of the Nucifer detector located in Saclay, France. It should be noted that only neutron transport is dealt with in this work and that all nuclear data come from JEFF-3.1.1 or ENDF/B-VII.0 evaluations, including fission data when needed. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

SAPHIRE 8 Software Independent Verification and Validation Plan

SAPHIRE 8 is being developed with a phased or cyclic iterative rapid application development methodology. Due to this approach, a similar approach is being taken for the IV&V activities on each vital software object. The IV&V plan is structured around NUREG/BR-0167, “Software Quality Assurance Program and Guidelines,” February 1993. The Nuclear Regulatory Research Office Instruction No.: PRM-12, “Software Quality Assurance for RES Sponsored Codes,” March 26, 2007 specifies that RES-sponsored software is to be evaluated against NUREG/BR-0167. Per the guidance in NUREG/BR-0167, SAPHIRE is classified as “Level 1.” Level 1 software corresponds to technical application software used in a safety decision.

99 GENERAL AND MISCELLANEOUS↗

SU-E-T-384: Experimental Verification of a Monte Carlo Linear Accelerator Model Using a Radiochromic Film Stack Dosimeter

Purpose: To experimentally verify a Monte Carlo (MC) linear accelerator model for the simulation of intensity-modulated radiation therapy (IMRT) treatments of moving targets. Methods: A Varian Clinac™ 21EX linear accelerator was modeled using the EGSnrc user code BEAMnrc. The mean energy, radial-intensity distribution, and divergence of the electron beam incident on the bremsstrahlung target were adjusted to achieve agreement between simulated and measured percentage-depth-dose and transverse field profiles for a 6 MV beam. A seven-field step-and-shoot IMRT lung procedure was prepared using Varian Eclipse™ treatment planning software. The plan was delivered using a Clinac™ 21EX linear accelerator and measured with a Gafchromic™ EBT2 film stack dosimeter (FSD) in two separate static geometries: within a cylindrical water-equivalent-plastic phantom and within an anthropomorphic chest phantom. Two measurements were completed in each setup. The dose distribution for each geometry was simulated using the EGSnrc user code DOSXYZnrc. MC geometries of the treatment couch, cylindrical phantom, and chest phantom were developed by thresholding CT data sets using MATLAB™. The FSD was modeled as water. The measured and simulated dose distributions were normalized to the median dose within the FSD. Results: Using an electron beam with a mean energy of 6.05 MeV, a Gaussian radial-intensity distribution with a full width at half maximum of 1.5 mm, and a divergence of 0°, the measured and simulated dose profiles agree within 1.75% and 1 mm. Measured and simulated dose distributions within both the cylindrical and chest phantoms agree within 3% over 94% of the FSD volume. The overall uncertainty in the FSD measurements is 3.1% (k=1). Conclusion: MC simulations agree with FSD measurements within measurement uncertainty, thereby verifying the accuracy of the linear accelerator model for the simulation of IMRT treatments of static geometries. The experimental verification will be extended to treatments of targets undergoing three-dimensional motion.

60 APPLIED LIFE SCIENCES↗

An algorithm to calculate a collapsed arc dose matrix in volumetric modulated arc therapy

Purpose: The delivery of volumetric modulated arc therapy (VMAT) is more complex than other conformal radiotherapy techniques. In this work, the authors present the feasibility of performing routine verification of VMAT delivery using a dose matrix measured by a gantry mounted 2D ion chamber array and corresponding dose matrix calculated by an inhouse developed algorithm.Methods: Pinnacle, v9.0, treatment planning system (TPS) was used in this study to generate VMAT plans for a 6 MV photon beam from an Elekta-Synergy linear accelerator. An algorithm was developed and implemented with inhouse computer code to calculate the dose matrix resulting from a VMAT arc in a plane perpendicular to the beam at isocenter. The algorithm was validated using measurement of standard patterns and clinical VMAT plans with a 2D ion chamber array. The clinical VMAT plans were also validated using ArcCHECK measurements. The measured and calculated dose matrices were compared using gamma ({gamma}) analysis with 3%/3 mm criteria and {gamma} tolerance of 1.Results: The dose matrix comparison of standard patterns has shown excellent agreement with the mean {gamma} pass rate 97.7 ({sigma}= 0.4)%. The validation of clinical VMAT plans using the dose matrix predicted by the algorithm and the corresponding measured dose matrices also showed good agreement with the mean {gamma} pass rate of 97.6 ({sigma}= 1.6)%. The validation of clinical VMAT plans using ArcCHECK measurements showed a mean pass rate of 95.6 ({sigma}= 1.8)%.Conclusions: The developed algorithm was shown to accurately predict the dose matrix, in a plane perpendicular to the beam, by considering all possible leaf trajectories in a VMAT delivery. This enables the verification of VMAT delivery using a 2D array detector mounted on a treatment head.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nuclear Energy Knowledge and Validation Center (NEKVaC) Needs Workshop Summary Report

The Department of Energy (DOE) has made significant progress developing simulation tools to predict the behavior of nuclear systems with greater accuracy and of increasing our capability to predict the behavior of these systems outside of the standard range of applications. These analytical tools require a more complex array of validation tests to accurately simulate the physics and multiple length and time scales. Results from modern simulations will allow experiment designers to narrow the range of conditions needed to bound system behavior and to optimize the deployment of instrumentation to limit the breadth and cost of the campaign. Modern validation, verification and uncertainty quantification (VVUQ) techniques enable analysts to extract information from experiments in a systematic manner and provide the users with a quantified uncertainty estimate. Unfortunately, the capability to perform experiments that would enable taking full advantage of the formalisms of these modern codes has progressed relatively little (with some notable exceptions in fuels and thermal-hydraulics); the majority of the experimental data available today is the "historic" data accumulated over the last decades of nuclear systems R&D. A validated code-model is a tool for users. An unvalidated code-model is useful for code developers to gain understanding, publish research results, attract funding, etc. As nuclear analysis codes have become more sophisticated, so have the measurement and validation methods and the challenges that confront them. A successful yet cost-effective validation effort requires expertise possessed only by a few, resources possessed only by the well-capitalized (or a willing collective), and a clear, well-defined objective (validating a code that is developed to satisfy the need(s) of an actual user). To that end, the Idaho National Laboratory established the Nuclear Energy Knowledge and Validation Center to address the challenges of modern code validation and to manage the knowledge from past, current, and future experimental campaigns. By pulling together the best minds involved in code development, experiment design, and validation to establish and disseminate best practices and new techniques, the Nuclear Energy Knowledge and Validation Center (NEKVaC or the ‘Center’) will be a resource for industry, DOE Programs, and academia validation efforts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part II. High dose rate {sup 192}Ir sources

Purpose: Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR){sup 192}Ir sources, as well as electronic brachytherapy sources. Part I of this paper discussed the applicators used with electronic brachytherapy sources. Part II will discuss those used with HDR {sup 192}Ir sources. Although the use of these applicators has gained in popularity, the dosimetric characteristics have not been independently verified. Additionally, there is no recognized method of output verification for quality assurance procedures with applicators like these. Methods: This work aims to create a cohesive method of output verification that can be used to determine the dose at the treatment surface as part of a quality assurance/commissioning process for surface applicators used with HDR electronic brachytherapy sources (Part I) and{sup 192}Ir sources (Part II). Air-kerma rate measurements for the {sup 192}Ir sources were completed with several models of small-volume ionization chambers to obtain an air-kerma rate at the treatment surface for each applicator. Correction factors were calculated using MCNP5 and EGSnrc Monte Carlo codes in order to determine an applicator-specific absorbed dose to water at the treatment surface from the measured air-kerma rate. Additionally, relative dose measurements of the surface dose distributions and characteristic depth dose curves were completed in-phantom. Results: Theoretical dose distributions and depth dose curves were generated for each applicator and agreed well with the measured values. A method of output verification was created that allows users to determine the applicator-specific dose to water at the treatment surface based on a measured air-kerma rate. Conclusions: The novel output verification methods described in this work will reduce uncertainties in dose delivery for treatments with these kinds of surface applicators, ultimately improving patient care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SAPHIRE 8 Software Independent Verification and Validation Plan

SAPHIRE 8 is being developed with a phased or cyclic iterative rapid application development methodology. Due to this approach, a similar approach is being taken for the IV&V activities on each vital software object. The IV&V plan is structured around NUREG/BR-0167, “Software Quality Assurance Program and Guidelines,” February 1993. The Nuclear Regulatory Research Office Instruction No.: PRM-12, “Software Quality Assurance for RES Sponsored Codes,” March 26, 2007 specifies that RES-sponsored software is to be evaluated against NUREG/BR-0167. Per the guidance in NUREG/BR-0167, SAPHIRE is classified as “Level 1.” Level 1 software corresponds to technical application software used in a safety decision.

99 GENERAL AND MISCELLANEOUS↗

Production and Testing of the VITAMIN-B7 Fine-Group and BUGLE-B7 Broad-Group Coupled Neutron/Gamma Cross-Section Libraries Derived from ENDF/B-VII.0 Nuclear Data

New coupled neutron-gamma cross-section libraries have been developed for use in light water reactor (LWR) shielding applications, including pressure vessel dosimetry calculations. The libraries, which were generated using Evaluated Nuclear Data File/B Version VII Release 0 (ENDF/B-VII.0), use the same fine-group and broad-group energy structures as the VITAMIN-B6 and BUGLE-96 libraries. The processing methodology used to generate both libraries is based on the methods used to develop VITAMIN-B6 and BUGLE-96 and is consistent with ANSI/ANS 6.1.2. The ENDF data were first processed into the fine-group pseudo-problem-independent VITAMIN-B7 library and then collapsed into the broad-group BUGLE-B7 library. The VITAMIN-B7 library contains data for 391 nuclides. This represents a significant increase compared to the VITAMIN-B6 library, which contained data for 120 nuclides. The BUGLE-B7 library contains data for the same nuclides as BUGLE-96, and maintains the same numeric IDs for those nuclides. The broad-group data includes nuclides which are infinitely dilute and group collapsed using a concrete weighting spectrum, as well as nuclides which are self-shielded and group collapsed using weighting spectra representative of important regions of LWRs. The verification and validation of the new libraries includes a set of critical benchmark experiments, a set of regression tests that are used to evaluate multigroup crosssection libraries in the SCALE code system, and three pressure vessel dosimetry benchmarks. Results of these tests confirm that the new libraries are appropriate for use in LWR shielding analyses and meet the requirements of Regulatory Guide 1.190.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Using Verified Lifting to Optimize Legacy Stencil Codes (Final Project Report)

This project investigated new techniques for compiling stencil and stencil-like computations. Stencils computations are commonly found in applications such as image processing, physical simulations, image processing, and machine learning. In recent years, many high-performance domain-specific languages (DSLs) have been proposed to optimize stencil computations. To leverage such DSLs, however, existing codes often need to be rewritten. Such rewriting is manual, labor intensive, and error-prone. To alleviate such issues, this project investigated the application of program synthesis and artificial learning techniques to enable stencil computations to automatically leverage new high-performance DSLs. Rather than constructing syntax driven rules, verified lifting uses program synthesis to search for a target code fragment to compile the given input code into. In addition, it also searches for a proof that validates how the found target code fragment preserves the semantics of the original input. Thus, the target code fragment is guaranteed to be semantically equivalent to the input.

97 MATHEMATICS AND COMPUTING↗

Validation of NEAMS Tools Using MSRE Data

This report documents the benchmarks developed and performed for the tools and codes developed under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program utilizing the MSRE experiment data. There are three focus areas explored in this work: fuel evolution, CFD, and system transient analyses. Fuel depletion is important for MSR reactor physics and fuel cycle analysis. Fuel depletion capability is currently being developed in the Griffin reactor physics code. To support this, a benchmark problem is developed using the MSRE data and an existing depletion code with flowing fuel analysis functionality (ADDER) to validate this new capability in Griffin. The ADDER calculation is compared with the TRITON-MSR results as well as the MSRE experimental data. This benchmark can be directly used to verify and validate the Griffin fuel depletion capability in future years. For CFD simulation, the MSRE CAD model is obtained from the Copenhagen Atomics and a mesh is generated for the MSRE inlet plenum. The Nek5000 code will be employed to find the flow distribution in the MSRE inlet plenum based on the mesh generated. For system analysis, a simple benchmark problem for three types of MSR system transients is developed. The SAM and SPECTRA codes are used to solve the simple problem, and the results from the two codes agree well. The SAM code is also employed to obtain the frequency response of the MSRE system at the 5 and 8 MWt power levels. The results agree well with the experiment measurements. These verification and validation efforts gives SAM users more confidence in MSR system transient simulations using SAM. Lastly, the SAM-Griffin Multiphysics coupling work is initiated. A simple one-way coupling of evaluating the precursor drift effect on the MSRE k-eff is demonstrated. This preliminary coupling work serves as the basis for future more complex Multiphysics simulation and modelling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OC6 Phase Ia: CFD Simulations of the Free-Decay Motion of the DeepCwind Semisubmersible

Currently, the design of floating offshore wind systems is primarily based on mid-fidelity models with empirical drag forces. The tuning of the model coefficients requires data from either experiments or high-fidelity simulations. As part of the OC6 (Offshore Code Comparison Collaboration, Continued, with Correlation, and unCertainty (OC6) is a project under the International Energy Agency Wind Task 30 framework) project, the present investigation explores the latter option. A verification and validation study of computational fluid dynamics (CFD) models of the DeepCwind semisubmersible undergoing free-decay motion is performed. Several institutions provided CFD results for validation against the OC6 experimental campaign. The objective is to evaluate whether the CFD setups of the participants can provide valid estimates of the hydrodynamic damping coefficients needed by mid-fidelity models. The linear and quadratic damping coefficients and the equivalent damping ratio are chosen as metrics for validation. Large numerical uncertainties are estimated for the linear and quadratic damping coefficients; however, the equivalent damping ratios are more consistently predicted with lower uncertainty. Some difference is observed between the experimental and CFD surge-decay motion, which is caused by mechanical damping not considered in the simulations that likely originated from the mooring setup, including a Coulomb-friction-type force. Overall, the simulations and the experiment show reasonable agreement, thus demonstrating the feasibility of using CFD simulations to tune mid-fidelity models.

17 WIND ENERGY↗