Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

SUPERMASSIVE BLACK HOLES WITH HIGH ACCRETION RATES IN ACTIVE GALACTIC NUCLEI. III. DETECTION OF Fe ii REVERBERATION IN NINE NARROW-LINE SEYFERT 1 GALAXIES

This is the third in a series of papers reporting on a large reverberation-mapping campaign aimed to study the properties of active galactic nuclei (AGNs) with high accretion rates. We present new results on the variability of the optical Fe ii emission lines in 10 AGNs observed by the Yunnan Observatory 2.4 m telescope from 2012 to 2013. We detect statistically significant time lags, relative to the AGN continuum, in nine of the sources. This accurate measurement is achieved using a sophisticated spectral fitting scheme that allows for apparent flux variations of the host galaxy, and several narrow lines, due to the changing observing conditions. Six of the newly detected lags are indistinguishable from the Hβ lags measured in the same sources. Two are significantly longer and one is slightly shorter. Combining these findings with the Fe ii lags reported in previous studies, we find an Fe ii radius–luminosity relationship similar to the one for Hβ, although our sample by itself shows no clear correlation. The results support the idea that Fe ii emission lines originate in photoionized gas, which, for the majority of the newly reported objects, is indistinguishable from the Hβ-emitting gas. We also present a tentative correlation between the lag and intensity of Fe ii and Hβ and comment on its possible origin.

79 ASTRONOMY AND ASTROPHYSICS↗

Polarized quasiperiodic structures in pulsar radio emission reflect temporal modulations of non-stationary plasma flow

Bright single pulses of many radio pulsars show rapid intensity fluctuations (called microstructure) when observed with time resolutions of tens of microseconds. Here, we report an analysis of Arecibo 59.5 μs resolution polarimetric observations of 11 P-band and 32 L-band pulsars with periods ranging from 150 ms to 3.7 s. These higher-frequency observations form the most reliable basis for detailed microstructure studies. Close inspection of individual pulses reveals that most pulses exhibit quasi-periodicities with a well-defined periodicity timescale (P{sub μ}). While we find some pulses with deeply modulating microstructure, most pulses show low-amplitude modulations on top of broad smooth subpulse features, thereby making it difficult to infer periodicities. We have developed a method for such low-amplitude fluctuations wherein a smooth subpulse envelope is subtracted from each de-noised subpulse; the fluctuating portion of each subpulse is then used to estimate P{sub μ} via autocorrelation analysis. We find that the microstructure timescale P{sub μ} is common across all Stokes parameters of polarized pulsar signals. Moreover, no clear signature of curvature radiation in vacuum in highly resolved microstructures was found. Our analysis further shows strong correlation between P{sub μ} and the pulsar period P. We discuss implications of this result in terms of a coherent radiation model wherein radio emission arises due to formation and acceleration of electron–positron pairs in an inner vacuum gap over magnetic polar cap, and a subpulse corresponds to a series of non-stationary sparking discharges. We argue that in this model, P{sub μ} reflects the temporal modulation of non-stationary plasma flow.

79 ASTRONOMY AND ASTROPHYSICS↗

CHARACTERIZATION OF A SPURIOUS ONE-YEAR SIGNAL IN HARPS DATA

The HARPS spectrograph is showing an extreme stability, close to the m s{sup −1} level, over more than 10 years of data. However, the radial velocities of some stars are contaminated by a spurious one-year signal with an amplitude that can be as high as a few m s{sup −1}. This signal is in opposition of phase with the revolution of Earth around the Sun and can be explained by the deformation of spectral lines crossing block stitchings of the CCD when the spectrum of an observed star is alternatively blueshifted and redshifted due to the motion of Earth around the Sun. This annual perturbation can be suppressed by either removing those affected spectral lines from the correlation mask used by the cross-correlation technique to derive precise radial velocities, or by simply fitting a yearly sinusoid to the radial velocity data. This is mandatory if we want to detect long-period low-amplitude signals in the HARPS radial velocities of quiet solar-type stars.

79 ASTRONOMY AND ASTROPHYSICS↗

MODELING ATMOSPHERIC EMISSION FOR CMB GROUND-BASED OBSERVATIONS

Atmosphere is one of the most important noise sources for ground-based cosmic microwave background (CMB) experiments. By increasing optical loading on the detectors, it amplifies their effective noise, while its fluctuations introduce spatial and temporal correlations between detected signals. We present a physically motivated 3D-model of the atmosphere total intensity emission in the millimeter and sub-millimeter wavelengths. We derive a new analytical estimate for the correlation between detectors time-ordered data as a function of the instrument and survey design, as well as several atmospheric parameters such as wind, relative humidity, temperature and turbulence characteristics. Using an original numerical computation, we examine the effect of each physical parameter on the correlations in the time series of a given experiment. We then use a parametric-likelihood approach to validate the modeling and estimate atmosphere parameters from the polarbear-i project first season data set. We derive a new 1.0% upper limit on the linear polarization fraction of atmospheric emission. We also compare our results to previous studies and weather station measurements. The proposed model can be used for realistic simulations of future ground-based CMB observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing dynamical symmetry breaking using quantum-entangled photons

Here, we present an input/output analysis of photon-correlation experiments whereby a quantum mechanically entangled bi-photon state interacts with a material sample placed in one arm of a Hong–Ou–Mandel apparatus. We show that the output signal contains detailed information about subsequent entanglement with the microscopic quantum states in the sample. In particular, we apply the method to an ensemble of emitters interacting with a common photon mode within the open-system Dicke model. Our results indicate considerable dynamical information concerning spontaneous symmetry breaking can be revealed with such an experimental system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dark Energy Survey Year 3 results: galaxy clustering and systematics treatment for lens galaxy samples

ABSTRACT In this work, we present the galaxy clustering measurements of the two DES lens galaxy samples: a magnitude-limited sample optimized for the measurement of cosmological parameters, maglim, and a sample of luminous red galaxies selected with the redmagic algorithm. maglim/redmagic sample contains over 10 million/2.5 million galaxies and is divided into six/five photometric redshift bins spanning the range z ∈ [0.20, 1.05]/z ∈ [0.15, 0.90]. Both samples cover 4143 $\deg ^2$ over which we perform our analysis blind, measuring the angular correlation function with an S/N ∼ 63 for both samples. In a companion paper, these measurements of galaxy clustering are combined with the correlation functions of cosmic shear and galaxy–galaxy lensing of each sample to place cosmological constraints with a 3 × 2pt analysis. We conduct a thorough study of the mitigation of systematic effects caused by the spatially varying survey properties and we correct the measurements to remove artificial clustering signals. We employ several decontamination methods with different configurations to ensure the robustness of our corrections and to determine the systematic uncertainty that needs to be considered for the final cosmology analyses. We validate our fiducial methodology using lognormal mocks, showing that our decontamination procedure induces biases no greater than 0.5σ in the (Ωm, b) plane, where b is the galaxy bias.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark Energy Survey Year 3 results: Imprints of cosmic voids and superclusters in the Planck CMB lensing map

ABSTRACT The CMB lensing signal from cosmic voids and superclusters probes the growth of structure in the low-redshift cosmic web. In this analysis, we cross-correlated the Planck CMB lensing map with voids detected in the Dark Energy Survey Year 3 (Y3) data set (∼5000 deg2), expanding on previous measurements that used Y1 catalogues (∼1300 deg2). Given the increased statistical power compared to Y1 data, we report a 6.6σ detection of negative CMB convergence (κ) imprints using approximately 3600 voids detected from a redMaGiC luminous red galaxy sample. However, the measured signal is lower than expected from the MICE N-body simulation that is based on the ΛCDM model (parameters Ωm = 0.25, σ8 = 0.8), and the discrepancy is associated mostly with the void centre region. Considering the full void lensing profile, we fit an amplitude $A_{\kappa }=\kappa _{{\rm DES}}/\kappa _{{\rm MICE}}$ to a simulation-based template with fixed shape and found a moderate 2σ deviation in the signal with Aκ ≈ 0.79 ± 0.12. We also examined the WebSky simulation that is based on a Planck 2018 ΛCDM cosmology, but the results were even less consistent given the slightly higher matter density fluctuations than in MICE. We then identified superclusters in the DES and the MICE catalogues, and detected their imprints at the 8.4σ level; again with a lower-than-expected Aκ = 0.84 ± 0.10 amplitude. The combination of voids and superclusters yields a 10.3σ detection with an Aκ = 0.82 ± 0.08 constraint on the CMB lensing amplitude, thus the overall signal is 2.3σ weaker than expected from MICE.

79 ASTRONOMY AND ASTROPHYSICS↗

Trigonal symmetry breaking and its electronic effects in the two-dimensional dihalides MX 2 and trihalides MX 3

We study the consequences of the approximately trigonal (D 3d ) point symmetry of the transition metal (M) site in two-dimensional van der Waals MX 2 dihalides and MX 3 trihalides. The trigonal symmetry leads to a 2-2-1 orbital splitting of the transition metal d shell, which is best represented by d orbitals that describe the trigonal rather than Oh symmetry. The ligand-ligand bond length differences (rather than metal-ligand) take the role of a Jahn-Teller-like mode and in combination with interlayer distances and dimensionality effects tune the crystal field splittings and bandwidths. These effects, in turn, are amplified by electronic correlation effects—leading to crystal field splittings of the order of 0.1–1 eV between the singlet and the lowest orbital doublet—as opposed to the often assumed degenerate 3 t 2g states. Our calculations explain why most of the materials in this family are insulating, and why these considerations have to be taken into account in realistic models of them. Further, orbital order coupled to various lower symmetry lattice modes may lift the remaining orbital degeneracies, and we explain how these may support unique electronic states using ZrI 2 and CuCl 2 as examples, and offer a brief overview of possible electronic configurations in this class of materials. By building and analyzing Wannier models adapted to the appropriate symmetry we examine how the interplay among trigonal symmetry, electronic correlation effects, and – d orbital charge transfer leads to insulating, orbitally polarized magnetic and/or orbital-selective Mott states, and we provide a simple framework and numerical tool for others. Our paper establishes a rigorous framework to understand, control, and tune the electronic states in low-dimensional correlated halides. Furthermore, our analysis shows that trigonal symmetry and its breaking is a key feature of the two-dimensional halides that needs to be accounted for in search of novel electronic states in materials ranging from CrI 3 to α–RuCl 3 .

2-dimensional systems↗

Novel patterns for vector mesons from the large-N{sub c} limit

We report on a relation between the decay constants of {rho}-like J{sup PC}=1{sup --} vector mesons, which arises solely from the perturbative analysis of the <VV>, <TT> and <VT> correlators at O({alpha}{sub s}{sup 0}) in the large-N{sub c} limit. We find f{sub V}{sup T}/f{sub V}=1/{radical}(2) for highly excited states together with a pattern of alternation in sign. Quite remarkably, recent lattice determinations reported f{sub {rho}}{sup T}({mu})/f{sub {rho}}=0.72(2) at {mu}=2 GeV, in excellent agreement with our large-N{sub c} result. This seems to suggest a pattern like f{sub Vn}{sup T}/f{sub Vn}=(-1){sup n}/{radical}(2) for the whole (1{sup --}) states. In order to test this conjecture in real QCD we construct a set of spectral sum rules, which turn out to comply nicely with this scenario.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the road to discovery of relic gravitational waves: The TE and BB correlations in the cosmic microwave background radiation

The detection of primordial gravitational waves is one of the biggest challenges of the present time. The existing (Wilkinson Microwave Anisotropy Probe) observations are helpful in achieving this goal, and the forthcoming experiments (Planck) are likely to complete this mission. We show that the 5-year Wilkinson Microwave Anisotropy Probe TE data contain a hint of the presence of the gravitational wave contribution. In terms of the parameter R, which gives the ratio of contributions from gravitational waves and density perturbations to the temperature quadrupole, the best-fit model produced R=0.24. Because of large residual noises, the uncertainty of this determination is still large, and it easily includes the R=0 hypothesis. However, the uncertainty will be strongly reduced in the forthcoming observations which are more sensitive. We numerically simulated the Planck data and concluded that the relic gravitational waves with R=0.24 will be present at a better than 3{sigma} level in the TE observational channel, and at a better than 2{sigma} level in the 'realistic' BB channel. The balloon-borne and ground-based observations may provide healthy competition for Planck in some parts of the lower-l spectrum.

39↗

CMB polarization map derived from the WMAP 5 year data through the harmonic internal linear combination method

We have derived whole-sky cosmic microwave background polarization maps from the WMAP 5 year polarization data, using the harmonic internal linear combination (HILC) method. Our HILC method incorporates spatial variability of linear weights in a natural way and yields continuous linear weights over the entire sky. To estimate the power spectrum of HILC maps, we have derived an unbiased quadratic estimator, which is similar to the WMAP team's cross-power estimator, but in a more convenient form for HILC maps. From our cosmic microwave background polarization map, we have obtained TE correlation and E mode power spectra without applying any mask. They are similar to the WMAP team's estimation and consistent with the WMAP best-fit {lambda}CDM model. Foreground reduction by the HILC method is more effective for high resolution and low noise data. Hence, our HILC method will enable effective foreground reduction in polarization data from the Planck surveyor.

39↗

Healing of polymer interfaces: Interfacial dynamics, entanglements, and strength

Self-healing of polymer films often takes place as the molecules diffuse across a damaged region, above their melting temperature. Using molecular dynamics simulations we probe the healing of polymer films and compare the results with those obtained for thermal welding of homopolymer slabs. These two processes differ from each other in their interfacial structure since damage leads to increased polydispersity and more short chains. A polymer sample was cut into two separate films that were then held together in the melt state. The recovery of the damaged film was followed as time elapsed and polymer molecules diffused across the interface. The mass uptake and formation of entanglements, as obtained from primitive path analysis, are extracted and correlated with the interfacial strength obtained from shear simulations. We find that the diffusion across the interface is signifcantly faster in the damaged film compared to welding because of the presence of short chains. Though interfacial entanglements increase more rapidly for the damaged films, a large fraction of these entanglements are near chain ends. As a result, the interfacial strength of the healing film increases more slowly than for welding. For both healing and welding, the interfacial strength saturates as the bulk entanglement density is recovered across the interface. However, the saturation strength of the damaged film is below the bulk strength for the polymer sample. At saturation, cut chains remain near the healing interface. They are less entangled and as a result they mechanically weaken the interface. When the strength of the interface saturates, the number of interfacial entanglements scales with the corresponding bulk entanglement density. Chain stiffness increases the density of entanglements, which increases the strength of the interface. Our results show that a few entanglements across the interface are sufficient to resist interfacial chain pullout and enhance the mechanical strength.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measurement of the 252 Cf ⁢(sf) prompt fission neutron spectrum utilizing 12 C ⁡(𝑛, 𝑛) and 9 Be ⁢(𝑛, 𝑛) neutron scattering reference measurements

The 252 Cf spontaneous fission (sf), prompt fission neutron spectrum (PFNS) is a fundamental quantity for nuclear physics measurements of neutron-emitting reactions. This energy distribution of neutrons emitted from fission has been considered a neutron data standard for decades and has been utilized as a reference for neutron detection efficiency, validation of Monte Carlo simulations, benchmarking of dosimetry standards, and more. A significant portion of the global collection of nuclear data on neutron-induced reactions is correlated with the 252 Cf ⁢(sf) PFNS. Despite the reliance on this quantity by the nuclear physics community, the historical collection of 252 Cf PFNS measurements display systematic disagreements that are not understood or easily explained. These experimental discrepancies could potentially bias the 252 Cf PFNS Standard evaluation. On top of this, these past experiments frequently employed correlated experimental measurement or analysis methods. The artificial intelligence (AI)/machine learning (ML)-informed californium chi-nuclear data experiment (AIACHNE) project was formed to (a) investigate these discrepancies utilizing AI/ML methods to identify outlying regions of literature data, assign these regions to features of the experiment itself, and perform an improved evaluation of the 252 Cf PFNS and (b) perform a new experimental measurement of this quantity designed to improve upon the existing literature database. Here, in this work, we report on the AIACHNE 252 Cf PFNS experiment utilizing a new analysis method uncorrelated with all previous measurements: neutron efficiency determinations based on elastic neutron scattering on 12 C and 9 Be . This new method provides an independent test of the existing literature data and evaluation of the 252 Cf ⁢(sf) PFNS. The method is described with detailed covariance quantification procedures, as well as a direct discussion of the sources of uncertainty described as requirements in the “Templates” series of papers. The 252 Cf ⁢(sf) PFNS reported in this work agrees well with the overall shape of the existing standard PFNS evaluation as well as many literature measurements, thus verifying the current evaluation utilizing new techniques. However, the results suggest that there are deficiencies in the angle-differential 12 C and 9 Be ⁢(𝑛, 𝑛) evaluated nuclear data, which produce unphysical structures in the reported result. While these structures are relatively minor, they become obvious because of the high statistical precision of the data and the expected smooth continuity of the 252 Cf ⁢(sf) PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A method for volumetric imaging in radiotherapy using single x-ray projection

Purpose: It is an intriguing problem to generate an instantaneous volumetric image based on the corresponding x-ray projection. The purpose of this study is to develop a new method to achieve this goal via a sparse learning approach. Methods: To extract motion information hidden in projection images, the authors partitioned a projection image into small rectangular patches. The authors utilized a sparse learning method to automatically select patches that have a high correlation with principal component analysis (PCA) coefficients of a lung motion model. A model that maps the patch intensity to the PCA coefficients was built along with the patch selection process. Based on this model, a measured projection can be used to predict the PCA coefficients, which are then further used to generate a motion vector field and hence a volumetric image. The authors have also proposed an intensity baseline correction method based on the partitioned projection, in which the first and the second moments of pixel intensities at a patch in a simulated projection image are matched with those in a measured one via a linear transformation. The proposed method has been validated in both simulated data and real phantom data. Results: The algorithm is able to identify patches that contain relevant motion information such as the diaphragm region. It is found that an intensity baseline correction step is important to remove the systematic error in the motion prediction. For the simulation case, the sparse learning model reduced the prediction error for the first PCA coefficient to 5%, compared to the 10% error when sparse learning was not used, and the 95th percentile error for the predicted motion vector was reduced from 2.40 to 0.92 mm. In the phantom case with a regular tumor motion, the predicted tumor trajectory was successfully reconstructed with a 0.82 mm error for tumor center localization compared to a 1.66 mm error without using the sparse learning method. When the tumor motion was driven by a real patient breathing signal with irregular periods and amplitudes, the average tumor center error was 0.6 mm. The algorithm robustness with respect to sparsity level, patch size, and presence or absence of diaphragm, as well as computation time, has also been studied. Conclusions: The authors have developed a new method that automatically identifies motion information from an x-ray projection, based on which a volumetric image is generated.

60 APPLIED LIFE SCIENCES↗

TU-G-204-01: BEST IN PHYSICS (IMAGING): Dynamic CT Myocardial Perfusion Measurement and Its Comparison to Fractional Flow Reserve

Purpose: To evaluate a first pass analysis (FPA) technique for CT perfusion measurement in a swine animal and its validation using fractional flow reserve (FFR) as a reference standard. Methods: Swine were placed under anesthesia and relevant physiologic parameters were continuously recorded. Intra-coronary adenosine was administered to induce maximum hyperemia. A pressure wire was advanced distal to the first diagonal branch of the left anterior descending (LAD) artery for FFR measurements and a balloon dilation catheter was inserted over the pressure wire into the proximal LAD to create varying levels of stenosis. Images were acquired with a 320-row wide volume CT scanner. Three main coronary perfusion beds were delineated in the myocardium using arteries extracted from CT angiography images using a minimum energy hypothesis. The integrated density in the perfusion bed was used to calculate perfusion using the FPA technique. The perfusion in the LAD bed over a range of stenosis severity was measured. The measured fractional perfusion was compared to FFR and linear regression was performed. Results: The measured fractional perfusion using the FPA technique (P-FPA) and FFR were related as P-FPA = 1.06FFR – 0.06 (r{sup 2} = 0.86). The perfusion measurements were calculated with only three to five total CT volume scans, which drastically reduces the radiation dose as compared with the existing techniques requiring 15–20 volume scans. Conclusion: The measured perfusion using the first pass analysis technique showed good correlation with FFR measurements as a reference standard. The technique for perfusion measurement can potentially make a substantial reduction in radiation dose as compared with the existing techniques.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-TeP1-01: An Efficient Method of 3D Patient Dose Reconstruction Based On EPID Measurements for Pre-Treatment Patient Specific QA

Purpose: To demonstrate an efficient and clinically relevant patient specific QA method by reconstructing 3D patient dose from 2D EPID images for IMRT plans. Also to determine the usefulness of 2D QA metrics when assessing 3D patient dose deviations. Methods: Using the method developed by King et al (Med Phys 39(5),2839–2847), EPID images of IMRT fields were acquired in air and converted to dose at 10 cm depth (SAD setup) in a flat virtual water phantom. Each EPID measured dose map was then divided by the corresponding treatment planning system (TPS) dose map calculated with an identical setup, to derive a 2D “error matrix”. For each field, the error matrix was used to adjust the doses along the respective ray lines in the original patient 3D dose. All field doses were combined to derive a reconstructed 3D patient dose for quantitative analysis. A software tool was developed to efficiently implement the entire process and was tested with a variety of IMRT plans for 2D (virtual flat phantom) and 3D (in-patient) QA analysis. Results: The method was tested on 60 IMRT plans. The mean (± standard deviation) 2D gamma (2%,2mm) pass rate (2D-GPR) was 97.4±3.0% and the mean 2D gamma index (2D-GI) was 0.35±0.06. The 3D PTV mean dose deviation was 1.8±0.8%. The analysis showed very weak correlations between both the 2D-GPR and 2D-GI when compared with PTV mean dose deviations (R2=0.3561 and 0.3632 respectively). Conclusion: Our method efficiently calculates 3D patient dose from 2D EPID images, utilising all of the advantages of an EPID-based dosimetry system. In this study, the 2D QA metrics did not predict the 3D patient dose deviation. This tool allows reporting of the 3D volumetric dose parameters thus providing more clinically relevant patient specific QA.

60 APPLIED LIFE SCIENCES↗

Experimental examination of ternary fission in nuclear track emulsion

Activities performed in preparation for the search for ternary fission of heavy nuclei and the analysis of fragment angular correlations with nuclear track emulsion and an automated microscope are detailed. Surface irradiation of nuclear emulsion by a Cf source was initiated. Planar events containing nothing but fragment triples were found and studied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-body entanglement and information rearrangement in nuclear many-body systems: a study of the Lipkin–Meshkov–Glick model

Here, we examine how effective-model-space (EMS) calculations of nuclear many-body systems rearrange and converge multi-particle entanglement. The generalized Lipkin-Meshkov-Glick (LMG) model is used to motivate and provide insight for future developments of entanglement-driven descriptions of nuclei. The effective approach is based on a truncation of the Hilbert space together with a variational rotation of the qubits (spins), which constitute the relevant elementary degrees of freedom. The non-commutivity of the rotation and truncation allows for an exponential improvement of the energy convergence throughout much of the model space. Our analysis examines measures of correlations and entanglement, and quantifies their convergence with increasing cut-off. We focus on one- and two-spin entanglement entropies, mutual information, and $n$-tangles for $n=2,4$ to estimate multi-body entanglement. The effective description strongly suppresses entropies and mutual information of the rotated spins, while being able to recover the exact results to a large extent with low cut-offs. Naive truncations of the bare Hamiltonian, on the other hand, artificially underestimate these measures. The $n$-tangles in the present model provide a basis-independent measures of $n$-particle entanglement. While these are more difficult to capture with the EMS description, the improvement in convergence, compared to truncations of the bare Hamiltonian, is significantly more dramatic. We conclude that the low-energy EMS techniques, that successfully provide predictive capabilities for low-lying observables in many-body systems, exhibit analogous efficacy for quantum correlations and multi-body entanglement in the LMG model, motivating future studies in nuclear many-body systems and effective field theories relevant to high-energy physics and nuclear physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗