Search NASA⌕ Search

SEARCH · Search NASA

Results for “data ordering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate

Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integration of a DER Management System in Riverside. Final report

The tasks in this project covered various aspects, including algorithm development, algorithm integration into a commercial Active Network Management (ANM) platform, hardware-in-the-loop (HIL) testing in an industry-standard testing platform, pilot demonstration in Riverside, California, and also cost and benefit analysis. The DERMS platform in this project can host different algorithms developed on different platforms (e.g., MATLAB and Python) and it can interact with different hardware devices (e.g., different PV inverters, battery inverters, and different sensors). The DER control solution are based on an advanced model-free, layered, and clustered DER control paradigm. At the core of the DER control algorithms was the concept of Extremum Seeking (ES), which is a model-free probing-based control technique. The ES-based control algorithms were tested on major real-world inverters; both individually and in a cluster. It was shown that even legacy equipment (or when paired with a few additional advanced equipment) can support such advanced control. The monitoring algorithms utilize a heterogeneous set of legacy and advanced sensor measurements, such as behind-the-meter DER sensors, distribution-level Phase Measurement Units, distribution-substation Supervisory Control and Data Acquisition (SCADA), and line current sensors, with their limited availability; in order to infer practical network conditions. Sensor data are utilized to achieve resource forecasting, phase identification, and distribution system state estimation. The technology that was developed and demonstrated in this project could be transformational to utilities, including the smaller municipal utilities such as in Riverside, which may not have the resources to deploy advanced distribution system and DERMS solutions in order to support high penetration of solar power integration. This project created a real-world prototype to provide utilities with an assessment of smart grid monitoring and control technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Urban Energy-Water Nexus: Utility-Level Water Flows and Embedded Energy

There are limited open source data available for determining water production/treatment and required energy for cities across the United States. This database represents the culmination of a two-year effort to obtain data from cities across the United States via open records requests in order to determine the state of the U.S. urban energy-water nexus. Data were requested at the daily or monthly scale when available for 127 cities across the United States, represented by 253 distinct water and sewer districts. Data were requested from cities larger than 100,000 people and from each state. In the case of states that did not have cities that met these criteria, the largest cities in those states were selected. The resulting database represents a drinking water service population of 81.4 million and a wastewater service population of 86.2 million people. Average daily demands for the United States were calculated to be 560 liters per capita for drinking water and 500 liters per capita of wastewater. The embedded energy within each of these resources is 340 kWh/1000 m3 and 430 kWh/1000 m3, respectively. Drinking water data at the annual scale are available for production volume (89 cities) and for embedded energy (73 cities). Annual wastewater data are available for treated volume (104 cities) and embedded energy (90 cities). Monthly data are available for drinking water volume and embedded energy (73 and 56 cities) and wastewater volume and embedded energy (88 and 70 cities). Please see the two related papers for this metadata are included with this submission. Each folder name is a city that contributed data to the collection effort (City+State Abbreviation). Within each folder is a .csv file with drinking water and wastewater volume and energy data. A READ-ME file within each folder details the contents of the folder within any relevant information pertaining to data collection. Data are on the order of a monthly timescale when available, and yearly if not. Please cite the following papers when using the database: Chini, C.M. and Stillwell, A.S. (2017). The State of U.S. Urban Water: Data and the Energy-Water Nexus. Water Resources Research. 54(3). DOI: https://doi.org/10.1002/2017WR022265 Chini, C.M., and Stillwell, A. (2016). Where are all the data? The case for a comprehensive water and wastewater utility database. Journal of Water Resources Planning and Management. 143(3). DOI: 10.1061/(ASCE)WR.1943-5452.0000739

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Confronting GRB prompt emission with a model for subphotospheric dissipation

The origin of the prompt emission in gamma-ray bursts (GRBs) is still an unsolved problem and several different mechanisms have been suggested. We fit Fermi GRB data with a photospheric emission model which includes dissipation of the jet kinetic energy below the photosphere. The resulting spectra are dominated by Comptonization and contain no significant contribution from synchrotron radiation. In order to fit to the data, we span a physically motivated part of the model's parameter space and create DREAM (Dissipation with Radiative Emission as A table Model), a table model for XSPEC. Here, we show that this model can describe different kinds of GRB spectra, including GRB 090618, representing a typical Band function spectrum, and GRB 100724B, illustrating a double peaked spectrum, previously fitted with a Band+blackbody model, suggesting they originate from a similar scenario. We also suggest that the main difference between these two types of bursts is the optical depth at the dissipation site.

79 ASTRONOMY AND ASTROPHYSICS↗

Next-to-leading-order correction to pion form factor in k{sub T} factorization

We calculate the next-to-leading-order (NLO) correction to the pion electromagnetic form factor at leading twist in the k{sub T} factorization theorem. Partons off-shell by k{sub T}{sup 2} are considered in both quark diagrams and effective diagrams for the transverse-momentum-dependent pion wave function. The light-cone singularities in the transverse-momentum-dependent pion wave function are regularized by rotating the Wilson lines away from the light cone. The soft divergences from gluon exchanges among initial- and fal-state partons cancel exactly. We derive the infrared-finite k{sub T}-dependent NLO hard kernel for the pion electromagnetic form factor by taking the difference of the above two sets of diagrams. Varying the renormalization and factorization scales, we find that the NLO correction is smaller, when both the scales are set to the invariant masses of internal particles: it becomes lower than 40% of the leading-order contribution for momentum transfer squared Q{sup 2}>7 GeV{sup 2}. It is observed that the NLO leading-twist correction does not play an essential role in explaining the experimental data, but the leading-order higher-twist contribution does.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data for A Hybrid Biophysical-Machine Learning Framework for Diurnal Surface Energy Flux Estimation Using Proximal Sensing

Thermal infrared-based remote sensing of surface energy fluxes has traditionally relied on high spatial resolution satellite data with revisit frequencies on the order of weeks. In this study, we evaluate a biophysics-based analytical surface energy balance model for predicting latent energy (LE) and sensible heat (H) fluxes using proximal sensing observations. The Surface Temperature Initiated Closure (STIC1.2) model has been extensively validated across a wide range of spatial and temporal scales using various satellite-derived thermal infrared data sets. Here we extend this validation by applying STIC at sub-hourly temporal resolution over multiple growing seasons for four distinct agricultural systems. We further develop and evaluate novel STIC variants that incorporate machine learning (ML) techniques to eliminate the need for surface energy balance observations, specifically net radiation and soil heat flux, thereby enhancing model applicability in data-sparse settings. The integration of a ML component to estimate surface available energy is shown to have strong predictive performance for both LE (R2 = 0.81–0.94) and H (R2 = 0.46–0.72) across all agricultural systems examined here, demonstrating the potential of hybrid biophysical-machine learning approaches for surface energy balance modeling with minimal data requirements. This study concludes with a novel application of explainable machine learning (exML) to diagnose sources of model error. This exML framework attributes residual prediction errors to both model input variables and environmental drivers not explicitly included in the simulation experiments. This approach provides a new pathway for improving model design and integrating previously overlooked yet influential variables into future model iterations.

AI/ML↗

Radionuclide Migration through Sediment and Concrete: 16 Years of Investigations

The Waste Management Project provides safe, compliant, and cost-effective waste management services for the Hanford Site and the U.S. Department of Energy (DOE) complex. Part of these services includes safe disposal of low-level waste and mixed low-level waste at the Hanford Low-Level Waste Burial Grounds in accordance with the requirements of DOE Order 435.1, Radioactive Waste Management. To partially satisfy these requirements, performance assessment analyses were completed and approved. DOE Order 435.1 also requires continuing data collection to increase confidence in the critical assumptions used in these analyses to characterize the operational features of the disposal facility that are relied on to satisfy the performance objectives identified in the order. Cement-based solidification and stabilization is considered for hazardous waste disposal because it is easily done and cost-efficient. One critical assumption is that concrete will be used as a waste form or container material at the Hanford Site to control and minimize the release of radionuclide constituents in waste into the surrounding environment. Concrete encasement would contain and isolate the waste packages from the hydrologic environment and act as an intrusion barrier. Any failure of concrete encasement may result in water intrusion and consequent mobilization of radionuclides from the waste packages. The radionuclides iodine-129, selenium-75, technetium-99, and uranium-238 have been identified as long-term dose contributors (Mann et al. 2001; Wood et al. 1995). Because of their anionic nature in aqueous solutions, these constituents of potential concern may be released from the encased concrete by mass flow and/or diffusion and migrate into the surrounding subsurface environment (Serne et al. 1989; 1992; 1993a, b; 1995). Therefore, it is necessary to assess the performance of the concrete encasement structure and the ability of the surrounding soil to retard radionuclide migration. Each of the test methods performed throughout the lifetime of the project has focused on different aspects of the concrete waste form weathering process. Diffusion of different analytes [technetium-99 (Tc-99), iodine-125 (I-125), stable iodine (I), uranium (U), and rhenium (Re)] has been quantified from experiments under both saturated and unsaturated conditions. The water-saturated conditions provide a conservative estimate of the concrete’s performance in situ, and the unsaturated conditions provide a more accurate estimate of the diffusion of contaminants from the concrete.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY2019 Radionuclide Migration Tests

The Waste Management Project provides safe, compliant, and cost-effective waste management services for the Hanford Site and the U.S. Department of Energy (DOE) complex. Part of these services includes safe disposal of low-level waste and mixed low-level waste at the Hanford Low-Level Waste Burial Grounds in accordance with the requirements of DOE Order 435.1, Radioactive Waste Management. To partially satisfy these requirements, performance assessment analyses were completed and approved. DOE Order 435.1 also requires continuing data collection to increase confidence in the critical assumptions used in these analyses to characterize the operational features of the disposal facility that are relied on to satisfy the performance objectives identified in the order.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY 2020 Radionuclide Migration Project Status

The Waste Management Project provides safe, compliant, and cost-effective waste management services for the Hanford Site and the U.S. Department of Energy (DOE) complex. Part of these services includes safe disposal of low-level waste and mixed low-level waste at the Hanford Low-Level Waste Burial Grounds in accordance with the requirements of DOE Order 435.1, Radioactive Waste Management. To partially satisfy these requirements, performance assessment analyses were completed and approved. DOE Order 435.1 also requires continuing data collection to increase confidence in the critical assumptions used in these analyses to characterize the operational features of the disposal facility that are relied on to satisfy the performance objectives identified in the order.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wind Direction Bias in Generating Wind Roses and Conducting Sector-Based Air-Dispersion Modeling

Certain widely used wind rose programs and air dispersion models use an overly-simple data-transfer algorithm that induces a directional bias in their output products. The purpose of this paper is to provide a revised algorithm that corrects the aliasing bias that occurs when the internals in reported wind direction data are on the same order of magnitude, but not equal to the intervals used in the wind direction summaries. The directional bias issue arises when output products in 22.5-degree sectors are produced from 10-degree wind direction data, which affects the results of simulations of air and surface concentrations using widely applied air-dispersion models. Datasets or models with the bias discussed here give consistent positive biases (approximately 30%) for cardinal direction sectors (north, south, east, and west) and consistent negative biases for all the other sectors (approximately -10%). Data summary and air dispersion programs providing outputs in directions sectors that do not match the observational sectors need to be checked for this bias. A revised data-transfer algorithm is provided that corrects the aliasing bias that can occur in transferring wind direction data between different sectors widths.

54 ENVIRONMENTAL SCIENCES↗

Polar Liquid Cloud Base Detection Algorithms for High Spectral Resolution or Micropulse Lidar Data

Liquid layers in clouds affect their microphysical processes, as well as the atmospheric energy budget. However, explicit liquid cloud base height (LCBH) detection algorithms using ground-based instruments (e.g., lidars) are currently absent in the literature. Most studies use either fixed lidar parameter thresholds or cloud base height data products that do not distinguish between ice and liquid, all of which might introduce inconsistencies and errors in the resolved LCBHs. In this paper, two LCBH detection algorithms are presented; the first algorithm uses the high spectral resolution lidar (HSRL) data, and yields satisfactory results. The second algorithm incorporates micropulse lidar (MPL) data for the LCBH detection. A 1-year long comparison of data gathered at Barrow, Alaska, and McMurdo Station, Antarctica, which includes other cloud base detection methodologies (ceilometer, MPL value-added product cloud base height, LCBHs detected using a fixed MPL depolarization threshold) emphasize the merits of the MPL algorithm.

Silber, Israel↗

A strong electroweak phase transition from the inflaton field

We study a singlet scalar extension of the Standard Model. The singlet scalar is coupled non-minimally to gravity and assumed to drive inflation, and also couple sufficiently strongly with the SM Higgs field in order to provide for a strong first order electroweak phase transition. Requiring the model to describe inflation successfully, be compatible with the LHC data, and yield a strong first order electroweak phase transition, we identify the regions of the parameter space where the model is viable. We also include a singlet fermion with scalar coupling to the singlet scalar to probe the sensitivity of the constraints on additional degrees of freedom and their couplings in the singlet sector. We also comment on the general feasibility of these fields to act as dark matter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

HSRL Liquid cloud base height (nsaC1)

Liquid layers in clouds affect their microphysical processes, as well as the surface energy budget. Studies focusing on these and other areas of research are often in need of skillful estimation of liquid-bearing cloud-layer boundaries. The bases of these layers are predominantly determined by ground-based lidar instruments. Most studies requiring liquid cloud base height (LCBH) information use either fixed lidar depolarization and/or backscatter cross-section thresholds or cloud base height data products that do not distinguish between ice and liquid, all of which might introduce inconsistencies and errors in the resolved LCBH. This data set contains LCBH data at 1-min temoporal resolution based on an explicit LCBH detection algorithm, which uses the high-spectral-resolution lidar (HSRL) data. Examination of this algorithm in multiple cases and scenarios during numerous days and first-order comparison with microwave-radiometer data show satisfactory results.

54 ENVIRONMENTAL SCIENCES↗

Improving the precision of astrometry for space debris

The data reduction method for optical space debris observations has many similarities with the one adopted for surveying near-Earth objects; however, due to several specific issues, the image degradation is particularly critical, which makes it difficult to obtain precise astrometry. An automatic image reconstruction method was developed to improve the astrometry precision for space debris, based on the mathematical morphology operator. Variable structural elements along multiple directions are adopted for image transformation, and then all the resultant images are stacked to obtain a final result. To investigate its efficiency, trial observations are made with Global Positioning System satellites and the astrometry accuracy improvement is obtained by comparison with the reference positions. The results of our experiments indicate that the influence of degradation in astrometric CCD images is reduced, and the position accuracy of both objects and stellar stars is improved distinctly. Our technique will contribute significantly to optical data reduction and high-order precision astrometry for space debris.

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical evolution of multiple black holes with accurate initial data

We present numerical evolutions of three equal-mass black holes using the moving puncture approach. We calculate puncture initial data for three black holes solving the constraint equations by means of a high-order multigrid elliptic solver. Using these initial data, we show the results for three black hole evolutions with sixth-order waveform convergence. We compare results obtained with the BAM and AMSS-NCKU codes with previous results. The approximate analytic solution to the Hamiltonian constraint used in previous simulations of three black holes leads to different dynamics and waveforms. We present some numerical experiments showing the evolution of four black holes and the resulting gravitational waveform.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measured and projected beam backgrounds in the Belle II experiment at the SuperKEKB collider

The Belle II experiment at the SuperKEKB electron–positron collider aims to collect an unprecedented data set of 50 ab -1 to study CP -violation in the B -meson system and to search for Physics beyond the Standard Model. SuperKEKB is already the world’s highest-luminosity collider. In order to collect the planned data set within approximately one decade, the target is to reach a peak luminosity of 6 x 10 35 cm −2 s −1 by further increasing the beam currents and reducing the beam size at the interaction point by squeezing the betatron function down to β $^*_y$ = 0.3 mm. To ensure detector longevity and maintain good reconstruction performance, beam backgrounds must remain well controlled. We report on current background rates in Belle II and compare these against simulation. We find that a number of recent refinements have significantly improved the background simulation accuracy. Finally, we estimate the safety margins going forward. We predict that backgrounds should remain high but acceptable until a luminosity of at least 2.8 x 10 35 cm −2 s −1 is reached for β $^*_y$ = 0.6 mm. At this point, the most vulnerable Belle II detectors, the Time-of-Propagation (TOP) particle identification system and the Central Drift Chamber (CDC), have predicted background hit rates from single-beam and luminosity backgrounds that add up to approximately half of the maximum acceptable rates.

Detector background↗

Unexpected Hydride: Ce 4 B 2 C 2 H 2.42 , a Stuffed Variant of the Nd 2 BC Structure Type

Ce 4 B 2 C 2 H 2.42 was grown as large crystals from a cerium/copper eutectic flux. The structure was characterized by single-crystal X-ray and neutron diffraction and was found to be a stuffed variant of Nd 2 BC with the addition of two interstitial hydrogen positions. The tetrahedral hydrogen position is fully occupied, while the octahedral position has an occupancy of 42(3)%. Initial synthesis was due to hydrogen contamination of the cerium metal but has been successfully repeated using anthracene as a carbon and hydrogen source. Density of states calculations suggest that the incorporation of hydrogen stabilizes the compound with respect to the nonhydrided model. Magnetic susceptibility data show a complex magnetic ordering at 7.7 K that originates from the localized electron on the Ce 3+ in the structure. The trivalent state is also supported by X-ray photoelectron spectroscopy measurements. Heat capacity and electrical resistivity data show that the phase transition is broad in temperature, which may be due to structural disorder. Furthermore, the large low temperature value of C/T also indicates possible heavy fermion behavior.

36 MATERIALS SCIENCE↗