Search NASA⌕ Search

SEARCH · Search NASA

Results for “deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Advanced processing of EBSD data to distinguish the complex microstructure evolution of a Cu-Ni-Si alloy induced by fatigue

Highlights: • Microstructure investigation of the fatigue behaviour of a Cu-Ni-Si alloy • Use of ECCI and EBSD to investigate the microstructure evolution related to fatigue dislocations structures • Characterisation of local plastic accommodation through EBSD misorientation criteria - Abstract: The present work aims at identifying the evolution of the microstructure of a Cu-Ni-Si (Corson alloy) alloy after low cycle fatigue by means of advanced electron microscopy analysis techniques (SEM-ECCI, Orientation Imaging Microscopy by means of SEM-EBSD and TEM). Deep attention is paid on the material subjected to high cyclic strains where a transient cellular dislocation structure transformed into precipitate free bands. It is shown that the formation of dislocation cells leads to a high GROD and high GOSaera value and its standard deviation. However, the presence of precipitate free bands results in the low GOSarea level and its low standard deviation.

36 MATERIALS SCIENCE↗

Co{sub 1−x}Zn{sub x}Fe{sub 2}O{sub 4} (0 ≤ x ≤ 1) nanocrystalline solid solution prepared by the polyol method: Characterization and magnetic properties

Highlights: ► Co–Zn ferrite nanoparticles were produced by soft chemistry. ► Cation distribution deviation from the thermodynamically stable one was evidenced. ► The magnetic characteristics were affected and differ from those of bulks. -- Abstract: Highly crystalline stoichiometric Co{sub 1−x}Zn{sub x}Fe{sub 2}O{sub 4} (0 ≤ x ≤ 1) nanoparticles were successfully synthesized by the polyol process. X-ray diffraction (XRD), X-ray fluorescence spectroscopy (XRF), transmission electron microscopy (TEM), infrared spectroscopy (IR), zero-field {sup 57}Fe Mössbauer spectrometry and magnetic measurements using a SQUID magnetometer were employed to investigate the effect of the substitution of Zn{sup 2+} ions for Co{sup 2+} ones on the structure, and the magnetic properties of the cobalt ferrite, CoFe{sub 2}O{sub 4}. The unit cell parameter almost increases linearly with increasing Zn concentration, x, following Vegard's law. The red and blue shifts observed for the metal-oxygen ν{sub 1} and ν{sub 2}IR vibration bands, respectively, were consistent with the preferential entrance of Zn{sup 2+} ions in tetrahedral sites. Besides, detailed magnetic investigation in correlation with the cation distribution has been reported. All the particles exhibit superparamagnetic behaviour at room temperature. In addition, the magnetic characteristics (blocking temperature, saturation magnetization, coercivity, Curie temperature) clearly depend on the chemical composition and cation distribution. Both the blocking temperature and Curie temperature decrease drastically with Zn composition, x, increase. Further, the saturation magnetization follows an almost bulk-like behaviour with values notably larger than that of the bulk, mainly attributed to cation distribution deviation.

36 MATERIALS SCIENCE↗

Ground-state energy trends in single and multilayered coupled InAs/GaAs quantum dots capped with InGaAs layers: Effects of InGaAs layer thickness and annealing temperature

Graphical abstract: - Highlights: • Investigation of ground state energy in single and multi-layered InAs/GaAs QD. • Strain reducing layer (InGaAs) prevents the formation of non-radiative. • Strain reducing layer (InGaAs) is responsible for high activation energy. • Significant deviation from the Varshni model, E(T) = E − αT{sup 2}/T + β. - Abstract: Vertically coupled, multilayered InAs/GaAs quantum dots (QDs) covered with thin InGaAs strain-reducing layers (SRLs) are in demand for various technological applications. We investigated low temperature photoluminescence of single and multilayered structures in which the SRL thickness was varied. The SRL layer was responsible for high activation energies. Deviation of experimental data from the Varshni (1967) model, E(T) = E − ∞ T{sup 2}/T + β, suggests that the InAs-layered QDs have properties different from those in bulk material. Anomalous ground-state peak linewidths (FWHM), especially for annealed multilayer structures, were observed. A ground-state peak blue-shift with a broadened linewidth was also observed. Loss of intensity was detected in samples annealed at 800 °C. Presence of SRLs prevents formation of non-radiative centers under high temperature annealing. The results indicate the potential importance of such structures in optoelectronic applications.

36 MATERIALS SCIENCE↗

Influence of Ga{sup 3+} ions on spectroscopic and dielectric features of multi component lithium lead boro bismuth silicate glasses doped with manganese ions

Graphical abstract: The plots between ε″(ω)ω vs. ε′(ω) and ε″(ω)/ω vs. ε′(ω) yield straight lines with slope 1/τ and τ, respectively. Considerable deviation from the straight line is observed in the high frequency region. Such deviation suggests spreading of relaxation times and this is attributed to the presence of multiple type of dipoles in the glass matrix. Variation of the parameters ωε″(ω) and ε″(ω)/ω with ε′(ω) of glass Li{sub 2}O–PbO–B{sub 2}O{sub 3}–SiO{sub 2}–Bi{sub 2}O{sub 3}–MnO multi-component glasses mixed with 2.0 mol% of Ga{sub 2}O{sub 3} measured at 373 K. - Highlights: • A series of Li{sub 2}O–PbO–B{sub 2}O{sub 3}–SiO{sub 2}–Bi{sub 2}O{sub 3}–MnO:Ga{sub 2}O{sub 3} glasses have been synthesized. • A variety of spectroscopic and dielectric properties have been investigated. • Analysis of the results indicated that glasses with below 3.0 mol% Ga{sub 2}O{sub 3} are good conducting materials. - Abstract: Multi-component glasses of the chemical composition 19.5Li{sub 2}O–20PbO–20B{sub 2}O{sub 3}–30SiO–(10 − x)Bi{sub 2}O{sub 3}–0.5MnO:xGa{sub 2}O{sub 3} with 0 ≤ x ≤ 5.0 have been synthesized. Spectroscopic (optical absorption, IR, Raman and ESR) and dielectric properties were investigated. Optical absorption and ESR spectral studies have indicated that managanese ions do exist in Mn{sup 3+} state in addition to Mn{sup 2+} state in the samples containing low concentration of Ga{sub 2}O{sub 3}. The IR and Raman studies indicated increasing degree of disorder in the glass network with the concentration of Ga{sub 2}O{sub 3} up to 3.0 mol%. The dielectric constant, loss and ac conductivity are observed to increase with the concentration of Ga{sub 2}O{sub 3} up to 3.0 mol%. The quantitative analysis of the results of dielectric properties has indicated an increase in the insulating strength of the glasses as the concentration of Ga{sub 2}O{sub 3} is raised beyond 3.0 mol%. This has been attributed to adaption of gallium ions from octahedral to tetrahedral coordination.

36 MATERIALS SCIENCE↗

Study of Maxwell–Wagner (M–W) relaxation behavior and hysteresis observed in bismuth titanate layered structure obtained by solution combustion synthesis using dextrose as fuel

Graphical abstract: X-ray diffraction studies show that phase formation and crystallinity was reached only after calcinations at 800 °C. Dielectric constant versus temperature curve shows ferroelectric to paraelectric transition temperature (T{sub c}) to be 650 °C. Complex impedance curves show deviation from Debye behavior. The material shows a thin PE Loop with low remnant polarization due to high conductivity in the as prepared sample. - Highlights: • Bi{sub 4}Ti{sub 3}O{sub 12} is synthesized using solution combustion technique with dextrose as fuel. • Dextrose has high reducing capacity (+24) and generates more no. of moles of gases. • Impedance studies show that the sample follows Maxwell–Wagner relaxation behavior. • Shows lower remnant polarization due to higher c-axis ratio. - Abstract: Structural, dielectric and ferroelectric properties of bismuth titanate (Bi{sub 4}Ti{sub 3}O{sub 12}) obtained by solution combustion technique using dextrose as fuel is studied extensively in this paper. Dextrose is used as fuel as it has high reducing valancy and generates more number of moles of gases during the reaction. X-ray diffraction studies show that phase formation and crystallinity was reached only after calcinations at 800 °C. Dielectric constant versus temperature curve shows ferroelectric to paraelectric transition temperature (T{sub c}) to be 650 °C. The dielectric loss is very less (tan δ < 1) at lower temperatures but increases around T{sub c} due to structural changes in the sample. Complex impedance curves show deviation from Debye behavior. The material shows a thin PE Loop with low remnant polarization due to high conductivity in the as prepared sample.

36 MATERIALS SCIENCE↗

Sodium doping effect on physicochemical properties of K{sub 1−x}Na{sub x}CaPb{sub 3}(PO{sub 4}){sub 3} (0 ≤ x ≤ 1) for the determination of mercury(II): Application in seawater samples

Highlights: • The apatite, K{sub 1−x}Na{sub x}CaPb{sub 3}(PO{sub 4}){sub 3} (0 ≤ x ≤ 1), was synthesized using reaction solid. • The obtained apatite was used to determine mercury in seawater samples from Morocco. • The effect of doping sodium into apatite on physic-chemical parameters was studied. • The influence of the electrochemical variables was investigated to determine mercury. - Abstract: A new chemically modified electrode was synthesized for the determination of mercury(II) using differential pulse anodic stripping voltammetry (DPASV). The electrode was modified by lacunar apatite K{sub 1−x}Na{sub x}CaPb{sub 3}(PO{sub 4}){sub 3} (0 ≤ x ≤ 1) synthesized using solid reaction. These powders were crystallized in the hexagonal system, space group P6{sub 3}/m. The effect of sodium content on structural, thermodynamic and electrochemical properties of prepared apatite has been studied. Therefore, the best results was obtained using NaCaPb{sub 3}(PO{sub 4}){sub 3} (x = 1) as modifier of carbon paste electrode for the electrochemical detection of mercury(II). The later ions were preconcentrated on the surface of the modified electrode and oxidized at 0.06 V vs. Ag/AgCl. The electroanalytical procedure comprises of two steps: the chemical accumulation of the analyte under open-circuit conditions followed by the electrochemical detection of the preconcentrated species using differential pulse voltammetry. The different parameters that govern the two steps were optimized. A linear response was obtained in the concentration range from 1.0 mol L{sup −1} × 10{sup −4} mol L{sup −1} to 2.0 mol L{sup −1} × 10{sup −7} mol L{sup −1} Hg(II) after activation of the electrode surface under the optimized conditions. The standard deviation was evaluated in a high and low concentration of mercury(II). The values ​​obtained for seven consecutive measurements were 1.24% and 5.07% of 1.0 mol L{sup −1} × 10{sup −4} mol L{sup −1} and 5.0 mol L{sup −1} × 10{sup −6} mol L{sup −1} mercury(II) solutions respectively. The detection limit and quantification limit for mercury(II), calculated from nine times standard deviation of blank/slope of the calibration graph, were 1.086 mol L{sup −1} × 10{sup −8} mol L{sup −1} and 3.62 mol L{sup −1} × 10{sup −8} mol L{sup −1}, respectively. The proposed chemically modified electrode was applied to determine mercury(II) in seawater samples.

36 MATERIALS SCIENCE↗

Dislocation density in fine grain-size spark-plasma sintered aluminum measured using high brightness synchrotron radiation

In this study, three-dimensional orientation mapping of samples of aluminum prepared by spark plasma sintering (SPS) with average grain sizes of 5 μm and 1 μm has been carried out using high-brightness synchrotron radiation, from which the geometrically necessary dislocation (GND) density has been determined. The low average measured GND density values confirm that the SPS process can be used to produce samples containing grains with dislocation density similar to that of fully recrystallized coarse-grained samples. Values of GND density are also compared to those obtained from electron back-scatter diffraction studies on the same material, highlighting the significantly higher angular resolution of the synchrotron data. For the 5 μm grain-size sample the measured GND density can account for a large fraction of the previously observed positive Hall-Petch deviation of this material. For the 1 μm grain-size sample, however, the GND-based strengthening contribution is much smaller than the reported positive Hall-Petch deviation, such that the additional strength may be reliably associated with dislocation source-limited strengthening.

36 MATERIALS SCIENCE↗

Correlation Between Detector Array Measurements and a Computer Algorithm for Enhanced Dynamic Wedge Profiles

Verification of dosimetric data computed by a treatment planning system is necessary in the commissioning process for any clinical software, just as it is necessary for any annual quality assurance testing. Direct verification of the dosimetric data is achievable when calculating the enhanced dynamic wedge (EDW) off-axis ratio at each point of interest. As mathematical models for hand-calculating such factors are still evolving, measurement of these external beam arrangements has proven significantly more accurate. This research presents a correlation for measured and planned data, specific for 6- and 18-MV photon beams on a Varian 21EX linear accelerator, using the EDW mode. Field generation was created using the Varian Eclipse treatment planning system. On treatment field delivery, the Sun Nuclear MapCHECK diode array was used to plot each beam profile in 2 dimensions. Wedge angles of 10 deg., 15 deg., 20 deg., 25 deg., 30 deg., 45 deg. and 60 deg. were studied here, under isocentric geometry, at a fixed water equivalent depth of 15 cm. Field size dependence was considered with each wedge and energy combination, where symmetric apertures of 5 x 5 cm{sup 2}, 10 x 10 cm{sup 2}, 15 x 15 cm{sup 2} and 20 x 20 cm{sup 2} were used. Accurate dosimetric results were found to be achievable when using this treatment planning system to within 2.8% maximum deviation, and to within 1% deviation averaged over all. The diode array also proved to be simple and ideally suited for EDW measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Implementation of in vivo Dosimetry with Isorad{sup TM} Semiconductor Diodes in Radiotherapy Treatments of the Pelvis

This report describes the results obtained with the Isorad{sup TM} (Red) semiconductor detectors for implementing an in vivo dosimetry program in patients subject to radiotherapy treatment of the pelvis. Four n-type semiconductor diodes were studied to characterize them for the application. The diode calibration consisted of establishing reading-to-dose conversion factors in reference conditions and a set of correction factors accounting for deviations of the diode response in comparison to that of an ion chamber. Treatments of the pelvis were performed by using an isocentric 'box' technique employing a beam of 18 MV with the shape of the fields defined by a multileaf collimator. The method of Rizzotti-Leunen was used to assess the dose at the isocenter based on measurements of the in vivo dose at the entrance and at the exit of each radiation field. The in vivo dose was evaluated for a population of 80 patients. The diodes exhibit good characteristics for their use in in vivo dosimetry; however, the high attenuation of the beam ({approx}12% at 5.0-cm depth) produced, and some important correction factors, must be taken into account. The correction factors determined, including the source-to-surface factor, were within a range of {+-}4%. The frequency histograms of the relative difference between the expected and measured doses at the entrance, the exit, and the isocenter, have mean values and standard deviations of -0.09% (2.18%), 0.77% (2.73%), and -0.11% (1.76%), respectively. The method implemented has proven to be very useful in the assessment of the in vivo dose in this kind of treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Detectability and Localization Accuracy of Implanted Fiducial Markers Determined on In-Room Computerized Tomography (CT) and Electronic Portal Images (EPI)

Many different methods of image guidance are available for radiotherapy treatment (IGRT). The aims of the study were (1) to determine the optimal diameter of gold markers for IGRT to the prostate; (2) to compare, using the Siemens Primatom, the relative merits of in-room computerized tomography (CT) and electronic portal image (EPI) for locating the marker seeds. Gold markers of differing widths were embedded in 2 phantoms (perspex slabs and anthropomorphic). Images were acquired with an amorphous silicon flat panel detector (Siemens Optivue 500) and with the in-room CT scanner (Siemens Somatom Balance). The EPIs were reviewed independently by 6 operators to determine which diameter marker could be best visualized. The optimal marker technique was determined by comparing the investigators' observed marker co-ordinates with the known locations within the phantom. The visibility of all markers on anterior-posterior EPIs was 100%. On the lateral EPI, of a possible 180 visualizations of 1.2-, 1.0-, and 0.8-mm diameter markers, 176 (97.8%), 151 (83.9%), and 132 (73.3%), respectively, were successful. On EPI, the average deviation of fiducial markers from the known position was less than 0.5 mm in any direction. On CT, the largest deviation (2.17 mm) of markers from the known coordinate position was in the superior-inferior direction, reflecting the 3.0-mm slice thickness used. EPI accurately located internal markers in all dimensions. The availability of 'gold standard' CT imagery at the treatment unit does not improve how accurately the position of markers in a phantom can be defined compared with EPI. However, CT imagery does provide important soft tissue information, the benefits of which are being investigated further.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Verification of Intensity Modulated Radiation Therapy of 172 Patients Treated for Various Disease Sites: Comparison of EBT Film Dosimetry, Ion Chamber Measurements, and Independent MU Calculations

Three independent dose verification methods for intensity modulated radiation therapy (IMRT) were evaluated. Planar IMRT dose distributions were delivered to EBT film and scanned with the Epson Expression 1680 flatbed scanner. The measured dose distributions were then compared to those calculated with a Pinnacle treatment planning system. The IMRT treatments consisted of 7 to 9 6-MV beams for different treatment sites. The films were analyzed using FilmQA (3cognition LLC, Great Neck, NY) software. Comparisons between measured and calculated dose distributions are reported as dose difference (DD) (pixels within {+-} 5%), distance to agreement (DTA) (3 mm), as well as gamma values ({gamma}) (dose = {+-} 3%, distance = 2 mm). Point dose measurements with an ion chamber at isocenter were compared to dose calculated at that point. An independent monitor units (MUs) calculation program was also used for verification. For the film dose distributions, DD values varied from 92% to 97%, with head-and-neck and lung treatments showing lower values. Gamma varied from 93% to 98%, and DTA was well above 99%. The isocenter dose measurements deviated from 0.008 to 0.028 from the calculated dose. The larger deviations were attributed to high-dose gradients at the isocenter. RadCalc MU calculations gave differences from 0.027 to 0.079. The larger differences observed were for beams crossing large areas of heterogeneous tissue and were attributed to the limitations of the simple path-length correction method employed in RadCalc. In conclusion, the 3 independent verification methods for each IMRT patient at our institution demonstrated very good agreement between measurements and calculations and gave us the confidence that our IMRT treatments are delivered accurately.

61 RADIATION PROTECTION AND DOSIMETRY↗

Image-Guided Stereotactic Body Radiotherapy for Lung Tumors Using BodyLoc With Tomotherapy: Clinical Implementation and Set-Up Accuracy

We investigated the use of a BodyLoc immobilization and stereotactic localization device combined with TomoTherapy megavoltage CT (MVCT) in lung stereotactic body radiotherapy (SBRT) to reduce set-up uncertainty and treatment time. Eight patients treated with 3-5 fractions of SBRT were retrospectively analyzed. A BodyLoc localizer was used in both CT simulation for localization and the initial patient treatment set-up. Patients were immobilized with a vacuum cushion on the back and a thermoplastic body cast on the anterior body. Pretreatment MVCT from the TomoTherapy unit was fused with the planning kilovoltage CT (KVCT) before each fraction of treatment to determine interfractional set-up error. The comparison of two MVCTs during a fraction of treatment resulted in the intrafractional uncertainty of the treatment. A total of 224 target isocenter shifts were analyzed to assess these inter- and intrafractional tumor motions. We found that for interfractional shifts, the mean set-up errors and standard deviations were -1.1 {+-} 2.8 mm, -2.5 {+-} 8.7 mm, and 4.1 {+-} 2.6 mm, for lateral, longitudinal, and vertical variation, respectively; the mean setup rotational variation was -0.3 {+-} 0.7 deg.; and the maximum motion was 13.5 mm in the longitudinal direction. For intrafractional shifts, the mean set-up errors and standard deviations were -0.1 {+-} 0.7 mm, -0.3 {+-} 2.0 mm, and 0.5 {+-} 1.1 mm for the lateral, longitudinal, and vertical shifts, respectively; the mean rotational variation was 0.1 {+-} 0.2 deg.; and the maximum motion was 3.8 mm in the longitudinal direction. There was no correlation among patient characteristics, set-up uncertainties, and isocenter shifts, and the interfractional set-up uncertainties were larger than the intrafractional isocenter shift. The results of this study suggested that image-guided stereotactic body radiotherapy using the BodyLoc immobilization system with TomoTherapy can improve treatment accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Daily Setup Variation With Tomotherapy Megavoltage Computed Tomography

The purpose of this study was to evaluate different setup uncertainties for various anatomic sites with TomoTherapy (registered) pretreatment megavoltage computed tomography (MVCT) and to provide optimal margin guidelines for these anatomic sites. Ninety-two patients with tumors in head and neck (HN), brain, lung, abdominal, or prostate regions were included in the study. MVCT was used to verify patient position and tumor target localization before each treatment. With the anatomy registration tool, MVCT provided real-time tumor shift coordinates relative to the positions where the simulation CT was performed. Thermoplastic facemasks were used for HN and brain treatments. Vac-Lok{sup TM} cushions were used to immobilize the lower extremities up to the thighs for prostate patients. No respiration suppression was administered for lung and abdomen patients. The interfractional setup variations were recorded and corrected before treatment. The mean interfractional setup error was the smallest for HN among the 5 sites analyzed. The average 3D displacement in lateral, longitudinal, and vertical directions for the 5 sites ranged from 2.2-7.7 mm for HN and lung, respectively. The largest movement in the lung was 2.0 cm in the longitudinal direction, with a mean error of 6.0 mm and standard deviation of 4.8 mm. The mean interfractional rotation variation was small and ranged from 0.2-0.5 deg., with the standard deviation ranging from 0.7-0.9 deg. Internal organ displacement was also investigated with a posttreatment MVCT scan for HN, lung, abdomen, and prostate patients. The maximum 3D intrafractional displacement across all sites was less than 4.5 mm. The interfractional systematic errors and random errors were analyzed and the suggested margins for HN, brain, prostate, abdomen, and lung in the lateral, longitudinal, and vertical directions were between 4.2 and 8.2 mm, 5.0 mm and 12.0 mm, and 1.5 mm and 6.8 mm, respectively. We suggest that TomoTherapy (registered) pretreatment MVCT can be used to improve the accuracy of patient positioning and reduce tumor margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Computed Tomography Scout Based Reference Point Localization to Conventional Film and Axial Computed Tomography

Identification of source positions after implantation is an important step in brachytherapy planning. Reconstruction is traditionally performed from films taken by conventional simulators, but these are gradually being replaced in the clinic by computed tomography (CT) simulators. The present study explored the use of a scout image-based reconstruction algorithm that replaces the use of traditional film, while exhibiting low sensitivity to metal-induced artifacts that can appear in 3D CT methods. In addition, the accuracy of an in-house graphical software implementation of scout-based reconstruction was compared with seed location reconstructions for 2 phantoms by conventional simulator and CT measurements. One phantom was constructed using a planar fixed grid of 1.5-mm diameter ball bearings (BBs) with 40-mm spacing. The second was a Fletcher-Suit applicator embedded in Styrofoam (Dow Chemical Co., Midland, MI) with one 3.2-mm-diameter BB inserted into each of 6 surrounding holes. Conventional simulator, kilovoltage CT (kVCT), megavoltage CT, and scout-based methods were evaluated by their ability to calculate the distance between seeds (40 mm for the fixed grid, 30-120 mm in Fletcher-Suit). All methods were able to reconstruct the fixed grid distances with an average deviation of <1%. The worst single deviations (approximately 6%) were exhibited in the 2 volumetric CT methods. In the Fletcher-Suit phantom, the intermodality agreement was within approximately 3%, with the conventional sim measuring marginally larger distances, with kVCT the smallest. All of the established reconstruction methods exhibited similar abilities to detect the distances between BBs. The 3D CT-based methods, with lower axial resolution, showed more variation, particularly with the smaller BBs. With a software implementation, scout-based reconstruction is an appealing approach because it simplifies data acquisition over film-based reconstruction without requiring any specialized equipment and does not carry risk of misreads caused by artifacts.

61 RADIATION PROTECTION AND DOSIMETRY↗

Consistency of vendor-specified activity values for {sup 192}Ir brachytherapy sources

A long-term comparison was done between the manufacturer-stated {sup 192}Ir activity and the measured {sup 192}Ir activities determined with a well-type ionization chamber. Sources for a Nucletron Micro Selectron high-dose-rate (HDR) unit were used for this purpose. The radioactive sources reference activities were determined using a PTW well-type ionization chamber traceable to the National Institute of Standards and Technology Primary Calibration Laboratory. The measurements were taken in a period of 56 months with 17 different radioactive sources. The manufacturer stated activities were taken from the source calibration certificate provided by the manufacturer. These values were compared with the measured activities. The results have shown that both the percentage deviation of the monthly control measurements with the well-type chamber and the ratio between the measured activities to the manufacturer-stated value lie within {+-} 2.5%. These results were compared with similar published data and with uncertainty level (3% of the mean and 5% maximum deviation from mean) for brachytherapy sources calibration recommended by the AAPM. It was concluded that a threshold level of {+-}2.5% can be used as a suitable quality assurance indicator to spot problems in our department. The typical {+-}5% uncertainty as provided by the manufacturers may be tightened to {+-}3% to be more in line with published AAPM reports.

61 RADIATION PROTECTION AND DOSIMETRY↗

Macrovoid resolved simulations of transport through HPRO relevant membrane geometries

Modeling the transport properties such as diffusivity and permeability of high pressure reverse osmosis (HPRO) membranes is critical for the selection and manufacture of membranes suitable for operation under high pressure. These properties can be significantly affected by the changes in heterogeneous pore structures due to compaction. Here, the modeling platform presented in this work resolves the two scale porosity in HPRO relevant membranes. A synthetic membrane geometry is constructed based on available experimental visualizations of pore structures. The simulations directly capture the flow channeling that results from a combination of material properties and geometric features of the macrovoids. A parametric study is presented to account for the transition of flow characteristics from a material governed regime to a macrovoid governed regime. Permeability of the membrane is evaluated using the simulation data and compared with an existing model that scales with the square of tortuosity over a range of material properties. The model is found to perform well under a narrow range of tortuosity while deviating from the calculated permeabilities at extreme conditions. The effective permeability of the membrane is found to vary by at least two orders of magnitude between the two flow regimes. It is also observed that tortuosity is a bounded property with its upper limit determined by the macrovoid geometry. Consequently, the tortuosity based correlations fail near a flow regime that is mainly governed by the macrovoids. The modeled permeability can be more than an order of magnitude smaller than the simulation result. A new model based on flux-weighted porosity of a membrane is introduced and its correlation with tortuosity is studied. The model agrees with the simulated data as, in addition to tortuosity, it also accounts for the flux partition within and outside the flow channels. Such correlations enable extending the existing understanding of flow characteristics to enhance predictability of porous media models.

42 ENGINEERING↗

Cation–polymer interactions and local heterogeneity determine the relative order of alkali cation diffusion coefficients in PEGDA hydrogels

Current research efforts are focused on endowing polymer membranes with ion–ion selectivity by incorporating ion–polymer interactions into materials to bias the selective partitioning and or diffusivity of one species over another. However, little is known about the impact of such interactions on the mechanisms of ion transport. In this study, we probe the influence of cation–polymer interactions on cation, anion, and salt diffusivity in a model membrane material, poly(ethylene glycol) diacrylate (PEGDA) by modeling concentrated polyethylene oxide solutions via molecular dynamics simulations. These results are compared to published experimental data for LiCl, NaCl, and KCl diffusion in PEGDA. Experimentally, the order of salt and cation diffusion coefficients for LiCl, NaCl, and KCl deviate from the order in aqueous solutions. Here, simulations identify these deviations to arise from cation–polymer coordination in the membrane. Both the fraction of bound cations and the average binding lifetime increases with decreasing cation hydration free energy (moving down the alkali series), leading to different diffusivity trends in the membrane compared to solution. However, to recover the experimentally observed order of diffusivities cations and salt in our simulations, we needed to incorporate membrane heterogeneity explicitly via a polymer charge scaling procedure. Together, our results indicate that cation–polymer interactions, as well as spatial heterogeneity within the membrane, play a critical role in dictating the observed order of alkali cation and salt diffusion coefficients in membranes.

36 MATERIALS SCIENCE↗

Thermodynamic investigation of the NaCl-KCl salt system from 25 to 950 °C

NaCl-KCl molten salt system has been proposed as a primary component of several promising heat transfer eutectics and fuel host for Generation IV molten salt reactors (MSR). In this work, several key thermodynamic parameters, including high temperature enthalpies, isobaric heat capacities (C p ) and molar enthalpies of mixing (ΔH mix ), of the NaCl -KCl system (NaCl, 75mol% NaCl – 25mol% KCl, 51mol% NaCl – 49mol% KCl, 25mol% NaCl – 75mol% KCl, and KCl) were measured by high temperature drop calorimetry (HTDC) utilizing laser sealed nickel and aluminum crucibles. Salts were checked for phase purity by X-ray diffraction (XRD), and water content by Karl Fischer coulometric titrimetry and thermogravimetric analysis (TGA). Thermo-mechanical analysis (TMA) utilizing custom-built boron nitride (BN) crucibles was employed to determine temperatures of phase transitions (solid $\rightarrow$ liquid) for the salts and plotted against the pseudobinary phase diagram for the NaCl-KCl system. Small deviations (3-10 %) were found among C p values obtained from HTDC, differential scanning calorimetry (DSC), and NIST, comparable to the average uncertainty based on two standard deviations of measured data that are ~6% for DSC and ~3% for HTDC. Additionally, the measured enthalpies and C p values of mixed NaCl-KCl salts (e.g., 51mol% NaCl – 49mol% KCl eutectic) were shown to behave as statistical mixtures of its pure endmembers, consistent with ΔH mix = ~ 0 kJ/mol at 800 °C, and a regular interaction parameter of Ω = 1.20 ± 0.76 kJ/mol. In conclusion, this study represents a step towards improved accuracy and precision in determinations of thermodynamic parameters of molten salts by using DSC, TMA, and HTDC, in completion of the Molten Salt Thermal Properties Database (MSTDB).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗