Search NASA⌕ Search

SEARCH · Search NASA

Results for “device packaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Rad-Hard, Miniaturized, Scalable, High-Voltage Switching Module for Power Applications Rad-Hard, Miniaturized

A paper discusses the successful development of a miniaturized radiation hardened high-voltage switching module operating at 2.5 kV suitable for space application. The high-voltage architecture was designed, fabricated, and tested using a commercial process that uses a unique combination of 0.25 micrometer CMOS (complementary metal oxide semiconductor) transistors and high-voltage lateral DMOS (diffusion metal oxide semiconductor) device with high breakdown voltage (greater than 650 V). The high-voltage requirements are achieved by stacking a number of DMOS devices within one module, while two modules can be placed in series to achieve higher voltages. Besides the high-voltage requirements, a second generation prototype is currently being developed to provide improved switching capabilities (rise time and fall time for full range of target voltages and currents), the ability to scale the output voltage to a desired value with good accuracy (few percent) up to 10 kV, to cover a wide range of high-voltage applications. In addition, to ensure miniaturization, long life, and high reliability, the assemblies will require intensive high-voltage electrostatic modeling (optimized E-field distribution throughout the module) to complete the proposed packaging approach and test the applicability of using advanced materials in a space-like environment (temperature and pressure) to help prevent potential arcing and corona due to high field regions. Finally, a single-event effect evaluation would have to be performed and single-event mitigation methods implemented at the design and system level or developed to ensure complete radiation hardness of the module.

Adell, Philippe C.↗

Plasma wave simulation based on versatile FEM solver on Alcator C-mod

The finite element method (FEM) has the potential of simulating plasma waves seamlessly from the core to the vacuum and antenna regions. We explored the possibility of using a versatile FEM solver package, COMSOL, for lower hybrid (LH) wave simulation. Special care was paid to boundary conditions to satisfy toroidal symmetry. The non-trivial issue of introducing hot plasma effects was addressed by an iterative algorithm. These techniques are verified both analytically and numerically. In the lower hybrid (LH) grill antenna coupling problem, the FEM solver successfully reproduced the solution that was obtained analytically. Propagation of LH waves on the Alcator C and Alcator C-MOD plasmas was compared with a ray-tracing code, showing good consistency. The approach based on the FEM is computationally less intensive compared to spectral domain solvers, and more suitable for the simulation of larger device such as ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-55: A Novel Applicator for High Dose Rate Brachytherapy Treatments of Ocular Conjunctiva

Purpose: To evaluate the clinical feasibility of IntraBeam intra operative kV irradiation beam device for ocular conjunctiva treatments. The Intra-Beam system offers a 4.4 mm diameter needle applicator, that is not suitable for treatment of a large surface with limits access. We propose an adaptor that will answer to this clinical need and provide initial dosimetry. Methods: The dose distribution of the needle applicator is non uniform and hence not suitable for treatment of relatively large surfaces. We designed an adapter to the needle applicator that will filter the X-rays and produce a conformal dose distribution over the treatment area while shielding surfaces to be spared. Dose distributions were simulated using FLUKA is a fully integrated particle physics Monte Carlo simulation package. Results: We designed a wedge applicator made of Polythermide window and stainless steel for collimating. We compare the dose distribution to that of the known needle and surface applicators. Conclusion: Initial dosimetry shows feasibility of this approach. While further refinements to the design may be warranted, the results support construction of a prototype and confirmation of the Monte Carlo dosimetry with measured data.

60 APPLIED LIFE SCIENCES↗

Reliable, Low-Cost, Low-Weight, Non-Hermetic Coating for MCM Applications

Through an Air Force Research Laboratory sponsored STM program, reliable, low-cost, low-weight, non-hermetic coatings for multi-chip-module(MCK applications were developed. Using the combination of Sandia Laboratory ATC-01 test chips, AvanTeco's moisture sensor chips(MSC's), and silicon slices, we have shown that organic and organic/inorganic overcoatings are reliable and practical non-hermetic moisture and oxidation barriers. The use of the MSC and unpassivated ATC-01 test chips provided rapid test results and comparison of moisture barrier quality of the overcoatings. The organic coatings studied were Parylene and Cyclotene. The inorganic coatings were Al2O3 and SiO2. The choice of coating(s) is dependent on the environment that the device(s) will be exposed to. We have defined four(4) classes of environments: Class I(moderate temperature/moderate humidity). Class H(high temperature/moderate humidity). Class III(moderate temperature/high humidity). Class IV(high temperature/high humidity). By subjecting the components to adhesion, FTIR, temperature-humidity(TH), pressure cooker(PCT), and electrical tests, we have determined that it is possible to reduce failures 50-70% for organic/inorganic coated components compared to organic coated components. All materials and equipment used are readily available commercially or are standard in most semiconductor fabrication lines. It is estimated that production cost for the developed technology would range from $1-10/module, compared to $20-200 for hermetically sealed packages.

Jones, Eric W.↗

Novel approaches to the construction of miniaturized analytical instrumentation

This paper focuses on the design, construction, preliminary testing, and potential applications of three forms of miniaturized analytical instrumentation. The first is an optical fiber instrument for monitoring pH and other cations in aqueous solutions. The instrument couples chemically selective indicators that were immobilized at porous polymeric films with a hardware package that provides the excitation light source, required optical components, and detection and data processing hardware. The second is a new form of a piezoelectric mass sensor. The sensor was fabricated by the deposition of a thin (5.5 micron) film of piezoelectric aluminum nitride (AIN). The completed deposition process yields a thin film resonator (TFR) that is shaped as a 400 micron square and supports a standing bulk acoustic wave in a longitudinal mode at frequencies of approx. 1 GHz. Various deposition and vapor sorption studies indicate that the mass sensitivity of the TFR's rival those of the most sensitive mass sensors currently available, though offering such performance in a markedly smaller device. The third couples a novel form of liquid chromatography with microlithographic miniaturization techniques. The status of the miniaturization effort, the goal of which is to achieve chip-scale separations, is briefly discussed.

Porter, Marc D.↗

Novel approaches to the construction of miniaturized analytical instrumentation

This paper focuses on the design, construction, preliminary testing, and potential applications of three forms of miniaturized analytical instrumentation. The first is an optical fiber instrument for monitoring pH and other cations in aqueous solutions. The instrument couples chemically selective indicators that were immobilized at porous polymeric films with a hardware package that provides the excitation light source, required optical components, and detection and data processing hardware. The second is a new form of a piezoelectric mass sensor. The sensor was fabricated by the deposition of a thin (5.5 micron) film of piezoelectric aluminum nitride (AIN). The completed deposition process yields a thin film resonator (TFR) that is shaped as a 400 micron square and supports a standing bulk acoustic wave in a longitudinal mode at frequencies of approx. 1 GHz. Various deposition and vapor sorption studies indicate that the mass sensitivity of the TFR's rival those of the most sensitive mass sensors currently available, though offering such performance in a markedly smaller device. The third couples a novel form of liquid chromatography with microlithographic miniaturization techniques. The status of the miniaturization effort, the goal of which is to achieve chip-scale separations, is briefly discussed.

Porter, Marc D.↗

Direct measurement of electron beam quality conversion factors using water calorimetry

Purpose: In this work, the authors describe an electron sealed water calorimeter (ESWcal) designed to directly measure absorbed dose to water in clinical electron beams and its use to derive electron beam quality conversion factors for two ionization chamber types. Methods: A functioning calorimeter prototype was constructed in-house and used to obtain reproducible measurements in clinical accelerator-based 6, 9, 12, 16, and 20 MeV electron beams. Corrections for the radiation field perturbation due to the presence of the glass calorimeter vessel were calculated using Monte Carlo (MC) simulations. The conductive heat transfer due to dose gradients and nonwater materials was also accounted for using a commercial finite element method software package. Results: The relative combined standard uncertainty on the ESWcal dose was estimated to be 0.50% for the 9–20 MeV beams and 1.00% for the 6 MeV beam, demonstrating that the development of a water calorimeter-based standard for electron beams over such a wide range of clinically relevant energies is feasible. The largest contributor to the uncertainty was the positioning (Type A, 0.10%–0.40%) and its influence on the perturbation correction (Type B, 0.10%–0.60%). As a preliminary validation, measurements performed with the ESWcal in a 6 MV photon beam were directly compared to results derived from the National Research Council of Canada (NRC) photon beam standard water calorimeter. These two independent devices were shown to agree well within the 0.43% combined relative uncertainty of the ESWcal for this beam type and quality. Absorbed dose electron beam quality conversion factors were measured using the ESWcal for the Exradin A12 and PTW Roos ionization chambers. The photon-electron conversion factor, k{sub ecal}, for the A12 was also experimentally determined. Nonstatistically significant differences of up to 0.7% were found when compared to the calculation-based factors listed in the AAPM’s TG-51 protocol. General agreement between the relative electron energy dependence of the PTW Roos data measured in this work and a recent MC-based study are also shown. Conclusions: This is the first time that water calorimetry has been successfully used to measure electron beam quality conversion factors for energies as low as 6 MeV (R{sub 50} = 2.25 cm)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study the Effects of Charged Particle Radiation on Gravitational Sensors in Space

Space-flight charging of free floating masses poses an unusual problem-- how can one control charge on the object without exerting a significant force on it? One approach is to make contact to the object with a fine wire. However, for many precision applications no physical contact is permissible, so charge must be conveyed in, a more sophisticated manner. One method has already been developed: Gravitational Probe B (GP-B) uses an ultraviolet photo-emission system described in ref 1. This system meets the experiment requirements, yet poses a number of constraints, including high power dissipation (approximately 10 W peak, approximately 1 W average), low current output (approximately 10(exp -13) A), and potential reliability problems associated with fiber optics system and the UV source. The aim of the current research is to improve this situation and, if possible, develop a more rugged and lower power alternative, usable in a wide range of situations. An potential alternative to the UV electron source is a Spindt-type field emission cathode. These consist of an array of extremely sharp silicon tips mounted in a standard IC package with provision for biasing them relative to the case potential. They are attractive as electron sources for space applications due to their low power consumption (10(exp -5) W), high current levels (10(exp -9) to 10(exp -5) A), and the absence of mechanical switching. Unfortunately, existing cathodes require special handling to avoid contamination and gas absorption. These contaminants can cause severe current fluctuations and eventual destruction of the cathode tips. Another potential drawback is the absence of any data indicating the possibility of bipolar current flow. This capability is needed because of the large uncertainties in the net charge transfer from cosmic rays to a free floating mass in space. More recent devices reduce the current fluctuations and destructive arcing by mounting the tips on a resistive substrate rather than a good conductor. This effectively wires a resistor to each individual tip, providing a current limit and thus greatly reducing the possibility of destructive arcing through an individual tip. An issue with this resistive layer is its range of operating temperatures. From the experience with the GP-B system, we hypothesized about using secondary electron emission for control of net charge transfer to an object. An important goal of the testing described below was to demonstrate the ability to apply both positive and negative charges to the test object from a single emitter.

Lipa, John A.↗

Miga Aero Actuator and 2D Machined Mechanical Binary Latch

Shape memory alloy (SMA) actuators provide the highest force-to-weight ratio of any known actuator. They can be designed for a wide variety of form factors from flat, thin packages, to form-matching packages for existing actuators. SMA actuators can be operated many thousands of times, so that ground testing is possible. Actuation speed can be accurately controlled from milliseconds to position and hold, and even electronic velocity-profile control is possible. SMA actuators provide a high degree of operational flexibility, and are truly smart actuators capable of being accurately controlled by onboard microprocessors across a wide range of voltages. The Miga Aero actuator is a SMA actuator designed specifically for spaceflight applications. Providing 13 mm of stroke with either 20- or 40-N output force in two different models, the Aero actuator is made from low-outgassing PEEK (polyether ether ketone) plastic, stainless steel, and nickel-titanium SMA wires. The modular actuator weighs less than 28 grams. The dorsal output attachment allows the Aero to be used in either PUSH or PULL modes by inverting the mounting orientation. The SPA1 actuator utilizes commercially available SMA actuator wire to provide 3/8-in. (approx. =.1 cm) of stroke at a force of over 28 lb (approx. = .125 N). The force is provided by a unique packaging of the single SMA wire that provides the output force of four SMA wires mechanically in parallel. The output load is shared by allowing the SMA wire to slip around the output attachment end to adjust or balance the load, preventing any individual wire segment from experiencing high loads during actuation. A built-in end limit switch prevents overheating of the SMA element following actuation when used in conjunction with the Miga Analog Driver [a simple MOSFET (metal oxide semiconductor field-effect transistor) switching circuit]. A simple 2D machined mechanical binary latch has been developed to complement the capabilities of SMA wire actuators. SMA actuators typically perform ideally as latch-release devices, wherein a spring-loaded device is released when the SMA actuator actuates in one direction. But many applications require cycling between two latched states open and closed.

Gummin, Mark A.↗

Innovative Drug Selection, Storage, and Shelf-Life Strategies for Exploration Spaceflight

Medications have been a part of space travel dating back to the Apollo missions. A safe and effective medication formulary is essential to maintaining crew health and performance during long-duration spaceflight outside of low Earth orbit (LEO). Distance from Earth creates four key operational changes that increase medical risks, including communication, resupply, crewmember health, and evacuation. The current spaceflight pharmaceutical formulary consists of medications indicated to treat a variety of anticipated medical events and healthcare needs during spaceflight, but depends on a robust consumables resupply chain, which may be strained for a Lunar, and possibly non-existent for a Mars mission. The specific medications selections for the formulary may change to optimally align with the mission, crew compliment, and spacecraft design. Medical support at long-duration exploration missions will differ from LEO missions due to mission duration, lack of consumables resupply, prolonged exposure to space radiation, and the absence of emergency medical return capability. Loss of medication resupply limits or removes the ability to replace medications that have been exhausted or degraded, potentially exacerbating the medical risk posture. To address these anticipated risks, long-duration missions must consider use of novel medical technologies, treatment modalities, and smart medical systems that offer greater crew autonomy, such as physiologically based pharmacokinetic modeling, drug repurposing, on demand drug synthesis, or wearable drug delivery / monitoring devices. Once an ideal formulary for exploration space is determined, it is essential to establish the chemical and physical stability of each medication compound, as well as its safety by identifying its degradation profiles and products. Although few studies have been conducted to provide evidence on the physicochemical stability of pharmaceuticals during space missions, the data suggests that the spaceflight environment may promote degradation in some pharmaceuticals. Formulary drug purity and efficacy should be verified by pharmaceutical stability assessments, and can be realized non-destructively, and accessed in remote environments. Non-destructive pharmaceutical analysis and statistical modelling techniques could optimize exploration spaceflight medical care by enabling early detection of suboptimal therapeutics. Likewise, novel packaging, storage strategies, and dosage form innovations are promising countermeasures to optimize pharmaceutical shelf life, purity, and quality of exploration spaceflight medications. As we prepare for more distant exploration missions, risk management planning for astronaut healthcare should include the assembly of a medication formulary that is comprehensive enough to prevent or treat anticipated medical events, remains safe and chemically stable, and retains sufficient potency to last for the duration of the mission. Following extensive review of the literature, we will present innovative formulary optimization strategies, pharmaceutical stability assessment techniques, and storage and packaging solutions that could enhance drug safety and efficacy for future exploration spaceflight missions.

Vernie R Daniels↗

Orbital refill of propulsion vehicle tankage

Techniques for orbital refueling of space based vehicles were developed and experimental programs to verify these techniques were identified. Orbital refueling operations were developed for two cryogenic orbital transfer vehicles (OTV's) and an Earth storable low thrust liquid propellant vehicle. Refueling operations were performed assuming an orbiter tanker for near term missions and an orbital depot. Analyses were conducted using liquid hydrogen and N2O4. The influence of a pressurization system and acquisition device on operations was also considered. Analyses showed that vehicle refill operations will be more difficult with a cryogen than with an earth storable. The major elements of a successful refill with cryogens include tank prechill and fill. Propellant quantities expended for tank prechill appear to to insignificant. Techniques were identified to avoid loss of liquid or excessive tank pressures during refill. It was determined that refill operations will be similar whether or not an orbiter tanker or orbital depot is available. Modeling analyses were performed for prechill and fill tests to be conducted assuming the Spacelab as a test bed, and a 1/10 scale model OTV (with LN2 as a test fluid) as an experimental package.

Merino, F.↗

Frontside-micromachined planar piezoresistive vibration sensor: Evaluating performance in the low frequency test range

Using a surface piezoresistor diffusion method and front-side only micromachining process, a planar piezoresistive vibration sensor was successfully developed with a simple structure, lower processing cost and fewer packaging difficulties. The vibration sensor had a large sector proof mass attached to a narrow flexure. Optimization of the boron diffusion piezoresistor placed on the edge of the narrow flexure greatly improved the sensitivity. Planar vibration sensors were fabricated and measured in order to analyze the effects of the sensor dimensions on performance, including the values of flexure width and the included angle of the sector. Sensitivities of fabricated planar sensors of 0.09–0.46 mV/V/g were measured up to a test frequency of 60 Hz. The sensor functioned at low voltages (<3 V) and currents (<1 mA) with a high sensitivity and low drift. At low background noise levels, the sensor had performance comparable to a commercial device.

36 MATERIALS SCIENCE↗

Programmable Beam Spatial Shaping System for the National Ignition Facility

A system of customized spatial light modulators has been installed onto the front end of the laser system at the National Ignition Facility (NIF). The devices are capable of shaping the beam profile at a low-fluence relay plane upstream of the amplifier chain. Their primary function is to introduce 'blocker' obscurations at programmed locations within the beam profile. These obscurations are positioned to shadow small, isolated flaws on downstream optical components that might otherwise limit the system operating energy. The modulators were designed to enable a drop-in retrofit of each of the 48 existing Pre Amplifier Modules (PAMs) without compromising their original performance specifications. This was accomplished by use of transmissive Optically Addressable Light Valves (OALV) based on a Bismuth Silicon Oxide photoconductive layer in series with a twisted nematic liquid crystal (LC) layer. These Programmable Spatial Shaper packages in combination with a flaw inspection system and optic registration strategy have provided a robust approach for extending the operational lifetime of high fluence laser optics on NIF.

42 ENGINEERING↗

Fast, Low Noise Photodetectors for Nuclear Physics

The overall goal of the Phase-II project was to construct and evaluate high performance SSPM technology for nuclear physics experiments. To achieve this overall objective, we first undertook optimization of the SSPM technology. This effort involved further enhancement of the optical quantum efficiency as well as the geometric efficiency (or fill-factor) of the SSPMs, which resulted in improvement of the photodetection efficiency of the SSPMs. Important SSPM parameters such as gain, dark count-rate, cross-talk, temporal response, after-pulsing, quantum efficiency and photodetection efficiency were evaluated for the optimized devices and these parameters were compared with those for Phase-I prototypes. Large area SSPMs (1 to 2 cm 2 ) were built using optimal design parameters. Noise analysis of large area SSPMs was performed. Upon coupling SSPMs to various scintillators (LSO/LYSO, LaBr 3 :Ce, NaI:Tl, LuAG:Ce etc.), energy resolution studies were carried. Timing resolution was also be measured with SSPMs coupled to fast scintillators (such as LaBr 3 :Ce, BaF 2 , LuAG:Ce, plastic and LSO/LYSO) using 511-keV gamma-rays ( 22 Na source). Multi-element SSPM arrays (6 x 6 format with ~1.5 x 1.5 mm 2 elements) were also designed and built using the CMOS process. These SSPM arrays were packaged and appropriate readout electronics was assembled. These SSPM arrays were operated with individual readout of each SSPM element. Large area (~1 cm 2 ) micro-pixel level PS-SSPMs with active and passive components to enable on-chip charge sharing for position sensing were also designed and built. Spatial, energy and timing resolution studies were conducted with the multi-element SSPM arrays as well as PS-SSPMs coupled to segmented scintillation arrays.

99 GENERAL AND MISCELLANEOUS↗

Unidirectional luminescence from InGaN/GaN quantum-well metasurfaces

III–nitride light-emitting diodes (LEDs) are the backbone of ubiquitous lighting and display applications. Imparting directional emission is an essential requirement for many LED implementations. Although optical packaging, nanopatterning and surface roughening4 techniques can enhance LED extraction, directing the emitted light requires bulky optical components. Optical metasurfaces provide precise control over transmitted and reflected waveforms, suggesting a new route for directing light emission. However, it is difficult to adapt metasurface concepts for incoherent light emission, due to the lack of a phase-locking incident wave. Here, we demonstrate a metasurface-based design of InGaN/GaN quantum-well structures that generate narrow, unidirectional transmission and emission lobes at arbitrary engineered angles. We further demonstrate 7-fold and 100-fold enhancements of total and air-coupled external quantum efficiencies, respectively. The results present a new strategy for exploiting metasurface functionality in light-emitting devices.

inorganic LEDs↗

Automated space processing payloads study. Volume 2, book 1: Technical report

The extent was investigated to which experiment hardware and operational requirements can be met by automatic control and material handling devices; payload and system concepts that make extensive use of automation technology are defined. Hardware requirements for each experiment were established and tabulated, and investigations of applicable existing hardware were documented. The capabilities and characteristics of industrial automation equipment, controls, and techniques are presented in the form of a summary of applicable equipment characteristics in three basic mutually-supporting formats. Facilities for performing groups of experiments are defined along with four levitation groups and three furnace groups; major hardware elements required to implement them were identified. A conceptual design definition of ten different automated processing facilities is presented along with the specific equipment to implement each facility and the design layouts of the different units. Constraints and packaging, weight, and power requirements for six payloads postulated for shuttle missions in the 1979 to 1982 time period were examined.

Source record↗

Aeroassist Technologies for Small Satellite Missions

Orbit insertion operations that require large V maneuvers using conventional propulsive technologies are mass inefficient and challenging to package within SmallSat form factors such as the popular CubeSat. Aeroassist technologies offer an alternative approach for V maneuvers and could revolutionize the use of SmallSats for exploration missions and increase the science return while reducing costs for orbital or entry missions to Mars, Venus and return to Earth. Aeroassist refers to the use of an atmosphere to accomplish a transportation system function using techniques such as aerobraking, aerocapture, aeroentry, and aerogravity assist. Aeroassist technologies are power efficient and tolerant to the radiation and thermal environment encountered in deep space, and can be integrated around or within SmallSat geometries. This presentation will discuss various Aeroassist technologies including conventional rigid aeroshells, inflatable decelerators, mechanically deployable decelerators and other drag devices and control methods that should be considered by Small Satellite mission design teams.

Cassell, Alan M.↗

The diverse applications of plasma

Plasma being the fourth state of matter has always been an attraction for Physicists and Chemists. With the advent of time, plasma energy has been recognized in having widening horizons in the field of Biomedical Sciences. Plasma medicine can be subdivided into three main fields; Non-thermal atmospheric-pressure direct plasma for medical therapy; Plasma-assisted modification of bio-relevant surfaces and Plasma-based bio-decontamination and sterilization. The basis of the research is that as it has free carrier molecules, it has the ability to target specific cells and regulate functions like wound healing. Plasma does not harm healthy human cells but can kill bacteria and possibly even cancer cells to help treat various diseases. Nosocomial infection control, prevention and containment of contagious diseases, disinfection of medical devices, surface treatment (heat and UV sensitive surfaces) are research of interest. Recent success in generating plasma at very low temperature ie. Cold plasma makes the therapy painless. It has the ability to activate cellular responses and important mechanisms in the body. They target specific molecules such as prothrombin for blood coagulation, cytokines for killing bacteria, and angiogenesis for tissue regeneration. Plasma has bactericidal, fungicidal and virucidal properties. Plasma technology has flourishing future in diverse fields like Textiles, Nanofabrication, Automotives, Waste management, Microbiology, Food Hygiene, Medical Science like Skin treatments, sterilisation of wounds, Hand disinfection, Dental treatments etc. Food hygiene using plasma can be achieved in disinfection of food containers, food surface disinfection, hygiene in food handling, preparation and packaging. Therefore Plasma is most promising field for budding Scientist for fluorishing research in Biological Sciences.

60 APPLIED LIFE SCIENCES↗